HomeMy WebLinkAboutGrading Plans - 10/30/2019P�QT ���� Accepted Siinple Grading Plan 10/30/2019 WL
S 1/2 LOT 10, BLOCK 156 OF FORT COLLINS CITY PLAT
628 Peterson Street, Fort Collins, C0.
"X"x.X" = LOT CORNER ELEVATION PER GRADING PLAN
x""."X "= EXTERIOR GRADE ELEVATION PER GRADING PLAN
T.O.F. = PROPOSED TOP OF FOUNDATION ELEVATION
NOTE: FINISHED GRADE AT FOUNDATION SHALL BE 8" LOWER THAN T.O.F.
Building Permit # B1906670
Goll Maidenhead Drive
Windsor, CO 80550
(970)-215-3887
josh@innovate-designbuild.com
Existing impervious Area:
House 1545 square feet
Front walk 75 square feet
Back Porch 560 square feet
detached garage 357 square feet (demoed)
Rear cobble walk 150 square feet
2687 square feet
28.31 % Impervious
New Proposed Impervious Area:
House 1545 square feet
Front walk 75 square feet
Back Porch 560 square feet
detached garage 576 squarefeet(new)
Rear cobble walk 150 square feet
2906 square feet
30.62% Impervious
z<.o�
PROPOSED
GARAGE
TOF=
4933.6f
0 30 60
Qsquare feet = +219
Impervious = +2.31 %
� a•
W �
�
� i�_
r7 0
Z i� � �
O �"� O
� O � �
W
W � a���
� �
— � S 89° 19'24" E � 189.85' ►
I � SOUTH 1/2 OF LOT 10
EXISTING 1 I
n�uat = �
� � �
�
� � a
— N 89° 19'24"W �
�
high
>I Lot Total 9492 square feet
�
1 89.83'
� Note
m Lot drainage is to remain substantially unchanged. With the front of
� the lot draining to the street (15%-20%) with the remainder and rear
� draining to the alley. (80%-85%) The proposed detached garage is
� in roughly the same location as the old demolished garage.
�
r
�M
— �
o ,6.0� o � �
W
gravel � � J
� drive � � J
.''i � � � Q
O
► _ � �
��� � ` ���� f�
Js�/i : ' �
-_ � 'Lu8j�'7 / _
_ ..�����1!!�,, �
V/ �'�� �`
NOTES: � � . �
1. THIS PLOT PLAN IS BASED ON WFORMATION PROVIDED 8Y THE OWNER/CONTRACTOR. THE
OWNER/CONTRACTOR SHALL VERIFY ALL LOT DIMENSIONS, SETBACK WFORMATION, EASEMENT
WIDTHS, GRADING ELEVATIONS AND THE PROXIMITY TO EXISTING SIRUCTURES WITH THE GOVERNING
AUTHORITY AND OR COVENANTS.
2. DIMENSIONS SHOWN AROUND THE PERIMETER OF THE STRUCTURE ARE TO EXTERIOR
FOUNDATION CORNERS.
3. THE CONTRACTOR SHALL VEPoFY ELEVATIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY
VARIATION TO THIS PLAN SHALL BE REPORTED TO LANDMARK ENGINEERING LTD. IMMEDIATELY.
4. THE CONTRACTOR SHALL NOT ENCROACH ON ADJACENT PROPERTY WITHOUT PERMISSION FROM
THE AFFECTED PROPERTY OWNERS.
5. PROVIDE AND MAINTAIN POSITIVE DRAINAGE AWAY FROM ALL FOUNDATION WALLS: A MINIMUM
SLOPE OF 10% IS REQUIRED FOR THE FIRST 10 FEET AND THEN A MINIMUM SLOPE OF 2i IS
REQUIRED THEREAFTER.
� �_'�='� TITLE: S� LOT 10, BLOCK 156 FTC
; Land�ar�
En�in�cr in� CLIENT: HORNER CONSTRUCTION SCALE: 1"=30'
3�21 Wesl C�s ��iow��,r HI-;r. -r:lcn�1 C<�lorodc EC537
��e�o� ea;-52eE .�Tou F��e �ahe; s;s b�sz .=�x �9,0� eb,-erss DATE: 29 Oct. 201 9 JOB #: HCONST-1 9G9B
n tl m r k I: �
This document is an instrument of professional service of Landmark Engineering Ltd. (LE.L.). Landmark shall, to the fuilest extent permitted
by low, be held harmless and released of any damage, liability, or cost arising or allegedly arising out of ony modifcation, change, or reuse
nf ihis doaiment hv others.