HomeMy WebLinkAboutGrading Plans - 01/16/2024DRAINAGE ANALYSIS
608 WHEDBEE STREET
FORT COLLINS, CO
January 15, 2024
City of Fort Collins
Stormwater Utility
700 Wood Street
Fort Collins, Colorado 80521
RE: 608 Whedbee Street
Fort Collins, Colorado
Permit No. B2309556
Dear Staff:
BLJRNT HILL LLC
Grading/Stormwater Plan Accepted
(Building Permit Released)
Accepted by: sagenbroad
Date: O1/16/2024
Burnt Hill LLC is pleased to submit this Drainage Analysis for the 608 Whedbee St residential property in Fort Collins, Colorado.
In general, this summary serves to document the stormwater impacts associated with the proposed site improvements
associated with Permit No. B2309556.
SITE LOCATION AND PROJECT DESCRIPTION
The 608 Whedbee Street site (referred herein as "the site") is situated in the Northwest Quarter of Section 13, Township 7
North, Range 69 West of the 6th Principal Meridian to the City of Fort Collins, Larimer County, Colorado. More specifically,
the property is recognized as Lot 14, Block 166 of the Fort Collins Subdivision. Proposed improvements to the existing
property consist of the following:
• Demolition of an existing garage and associated concrete and landscaping.
• Construction of an 816-sf detached garage with associated concrete stoops, concrete apron, and landscaping.
HYDROLOGIC CRITERIA
City of Fort Collins Rainfall Intensity-Duration-Frequency Curves, provided by Figure RA-16 of the Fort Collins Stormwater
Criteria Manual, are utilized for all hydrologic computations related to the site in its existing/historic and proposed conditions.
Since this site is relatively small and does not have complex drainage basins, the peak flow rates for design points have been
calculated based on the Rational Method as described in the USDCM and the City of Fort Collins Stormwater Criteria Manual
(FCSCM) with storm duration set equal to the time of concentration for each sub-basin. This method was used to analyze the
developed runoff from the 2-year (minor) and the 100-year (major) storm events. The Rational Method is widely accepted
for drainage design involving small drainage areas (less than 160 acres) and short time of concentrations. Runoff coefficients
are assumed based on impervious area and are given in the calculations attached.
EXISTING CONDITIONS
Hydrology
The site, located within the Old Town Drainage Basin, is 0.22-ac in size and currently consists of roofing, concrete pavement,
and grass landscaping. For the purposes of this drainage analysis, a 0.15-acre area, encompassing the improvements noted
above, is analyzed hydrologically. This drainage basin area, designated within this analysis as "Basin A", has an existing
imperviousness of 25.1%. Storm runoff within Basin A currently drains by way of overland flow to an alley adjacent to the
eastern property boundary.
Floodplain
The site is not located within a FEMA or City-regulatory floodway or floodplain.
IMPROVED CONDITIONS
Site improvements include an increase of approximately 678-sf of hard surface area relative to existing conditions, increasing
the Basin A imperviousness to 34.9%. The table on the following page summarizes the hydrologic impact associated with the
proposed site improvements relative to existing conditions. Refer to the hydrology calculations and Drainage Exhibit attached
for additional information.
WINDSOR, CO � 303 335-5508
DRAINAGE ANALYSIS
608 WHEDBEE STREET
FORT COLLINS, CO
HYDROLOGIC $UMMARY TABLE
Overall Area (acre)
*Roof (sf)
*Asphalt (sf)
*Concrete (sf)
*Gravel (sf)
*Landscape (sf)
% Imperviousness
Composite Cz
Composite C�oo
Qz (cfs)
Qioo (cfs)
Basin A
Existing Proposed
0.15 0.15
1, 340 1, 666
320 672
4,790
25.1%
0.43
0.54
0.14
0.59
4,112
34.9%
0.50
0.63
0.16
0.69
BURNT HILL LLC
Drainage patterns and runoff flows for the improved condition will remain largely unchanged from existing conditions; runoff
that does not infiltrate within Basin A is designed to be conveyed to the adjacent alley.
OLD TOWN ALLEY
Similar to the nature of Whedbee St and Smith St, the shared alley adjacent to the property is graded to drain northerly to
East Myrtle Street. An inlet at the intersection of E Myrtle St and Smith St is designed to capture runoff related to this shared
alley. The alleyway section of interest upstream of the mentioned inlet exists with positive slope from south to north and is
sufficient to convey runoff from the additional impervious area associated with the 608 Whedbee St garage (refer to the
attachments for additional information). Provided the negligible increase in stormwater related to minor storm events (e.g.,
2-year) and a minor increase in 100-year runoff, the site improvements provide an inconsequential increase of stormwater
to the alley. Due to the location of the 608 Whedbee St property relative to E Myrtle St and the nature of the existing alleyway,
stormwater runoff that fails to infiltrate from the site is adequately conveyed to E Myrtle St by way of the existing alleyway.
CONCLUSIONS
The proposed construction ofthe 608 Whedbee St garage and associated hardscape surfaces is intended to replace an existing
garage near the eastern property boundary. The existing alleyway adjacent to the eastern property boundary is sufficient to
convey developed stormwater runoff from the proposed improvements to the existing design point in E Myrtle St. A minor
increase in the overall imperviousness is proposed with the site improvements; however, increased runoff is conveyed to E
Myrtle St by way of the existing alley without impacting downstream properties.
If you should have any questions or comments as you review this drainage analysis, please feel free to contact us at your
convenience.
Sincerely,
Burnt Hill LLC
�� �
.
Colton Beck, P.E.
ATTACH M E NTS
- Hydrology Calculations
- Drainage Exhibit
- Alleyway Hydraulic Analysis
Rp,00 L/�
o �•<'
�p�':�9 A Nj�7"'
111 �`_
-o � 11�,2021� ; �
:�
�����SS/........��G�-
ONAL �
WINDSOR, CO � 303 335-5508
Rl1NOFF C�EFFICIENTS AND % IMPERVIDl15
6�8 Whedbee St. Fort Collins, CO
� �.
Areas Composite Hard 5urface
cn �p �p �q Imperviousness Area
Roof Asphalt Conerete Gravel Lawns
Total Total Composite Runoff Coeffieients �2�
Basin Design Pt.
acres %I = 90% %I =100% %I =10�°� %I =40% %1=Y°� (°�I) (sf) �z �wo
C=0.95 C=0.95 C=0.95 C=0.5� C=U.25
sf sf sf sf sf sf
A A 0.15 6,450 1,340 320 4,790 25.1% 1660 0.43 0.54
B B 0.07 3,050 850 517 1,683 43.1% 1367 0.56 0.70
Total 0.22 9,500 2,190 - 837 - 6,473 30.9%
i i i • i �
Areas Composite Hard Surface
Roof ��� Asphalt Conerete��� Gravel��� Lawns�� Imperviousness Area
Basin Oesign Pt. Total Total Composite RunoH Coeffieients �2j
acres sf %I = 9�% %I = I�0% %I =100% %I =40% % 1=2% (%p (sf) �s �roo
C=U.95 C=0.95 C=U.95 C=0.50 C=0.25
sf sf sf sf sf sf
A A 0.15 6,450 1,666 672 4,112 34.9% 2338 0.50 0.63
B B 0.07 3,050 850 517 1,683 43.1% 1367 0.56 0.70
Total 0.22 9,500 2,516 - 1,189 - 5,795 37.6%
Difference in Hard Surface Area (Basin AJ: 678
Difference in Hard Surface Area (Basin BJ: 0
Notes:
(1) Recommended % Imperviousness Values per Table 4.1-3 Surface Type - Percent Impervious in Fort Collins Stormwater Criteria Manual
(2) Runoff C is based Table 3.2-2. Surface Type - Runoff Coefficients and Table 3.2-3. Frequency Adjustment Factors in For[ Collins Stormwater Manual
TIME �F C�NCENTRATI�N (2-YR)
6�8 Whedbee 3t, Fort Collins, C�
�Z�t; _[1.87(1.1-CxCF�Ll�z]/51�3, 5= slope in %, L=length of overland flow (200' max urban, 500' max rural)
�3� V=(1.49/n)RZ�35'�Z, 5= slope in ft/ft, FCSCM Equation 5-4
�4�t�=L/(V*60 sec/min)
�s� Maximum t� = total length/180 + 10
�6�Minimumt�=5 min
Notes:
"� C=Cx*CF is less than or equal to 1.0 (Cf = 1.0)
TIME �F C�NCENTRATI�N (I0�-YR)
6�8 Whedhee St, Fort Collins, CO
Notes:
�1� G-Cx*CF is less than or equal to 1.0 (Cf = 1.25)
�Z� t; _[1.87�1.1-CxCF)L'�Z]/51�3, 5= slope in %, L=length of overland flow (200' max urban, 500' max rural)
�3�V=(1.49/n�RZ�351�Z, S= slope in ft/ft, FCSCM Equation 5-4
�4ftr L/(V*60sec/min)
�5� Maximum t� _ [otal length/180 + 10
�6f Minimum t�= S min
RATI�NAL METH�O PEAK RLINOFF
6�8 Whedhee St, Fort Collins, CO
� � �
�n
PROPOSED BASIN DESIGNATION
2 - YR RUNOFF COEFF.
100 - YR RUNOFF COEFF.
BASIN AREA (ACRE)
FLOW DIRECTION
BASIN BOUNDARY
EXISTING GRaUND
ELEVATION
— 6 a,
6
9� �� �
� —
�
�
�
�
�
w
� J
Z J
Q
�J
W
W �
�
�
i �
l
0� I � �f�
g`l� �,�,
I
�
�
�
�
�
�
�
�
�
b I
�ti��+ �;''�, `
�
I
�
�
�
�
�
�
�
�
;�
�
3`���`l
�� t
I
�
I
AI
608 WHEDBEE STREET o� �o� Zo� 40� �
DRAINAGE EXHIBIT �
SCALE: 1" = 20' 0
Z
DATE: January 14, 2024 PREPARED FOR: BRAD BLANK JOB NUMBER: 624001 SHEET 1 �F 1
LEGEND E MYRTLE ST I
R.O. W
Channel Report
Hydraflow Express Extension for Autodesk0 Civil 3D0 by Autodesk, Inc.
Section A-A: 100-Year Event
User-defined Highlighted
Invert Elev (ft) = 81.98 Depth (ft)
Slope (%) = 0.60 Q (cfs)
N-Value = 0.025 Area (sqft)
Velocity (ft/s)
Calculations Wetted Perim (ft)
Compute by: Known Q Crit Depth, Yc (ft)
Known Q(cfs) = 0.69 Top Width (ft)
EGL (ft)
(Sta, EI, n)-(Sta, EI, n)...
( 0.00, 82.15)-(5.00, 81.98, 0.025)-(10.00, 81.98, 0.025)-(15.00, 82.05, 0.025)-(20.00, 82.08, 0.025)
Sunday, Jan 14 2024
= 0.10
= 0.690
= 1.05
= 0.66
= 17.94
= 0.07
= 17.94
= 0.11
Elev (ft) Section
83.00
82.50
82.00
81.50
81.00
v
Depth (ft)
1.02
0.52
1 1:
-0.48
_n aQ
2 0 2 4 6 8
10 12 14
Sta (ft)
16 18 20 22 v Vv