Loading...
HomeMy WebLinkAboutGrading Plans - 07/28/2017Dennis R. Messner, P. E. Consulting Civil Engineer Stormwater Utility June 29, 2017 Project No. 1032-GRD-17 Service Center Grading plan accepted and permit 700 Wood Street released 7/28/2017 DM Fort Collins, Colorado 80522-0580 Re: Building Permit # B1702249, Lot 2, Whitman Storage Facility, Fort Collins, Colorado Gentletnen: The proposed single family residence to be constructed on the subject site is to be constructed and the lot graded to comply with the "Final Drainage and Erosion Control Report for the Whitman Storage Facility, P. D. P." The proposed elevation of the Finish Floor of the residence and the proposed lot grading have been designed to direct surface run off in the same manner as the original design for the subdivision. The run off generated on Lot 1 and Lot 3 that are situated to the west of the Lot 2 will flow across Lot 2 and be intercepted by the drainage swale located along the east border of Lot 2 or will flow southeasterly overland. The offsite run off from Lot 1 and Lot 3 will be directed to the existing subdivision detention pond. The original design and sizing of the subdivision detention pond considered the single family residence to be constructed on Lot 2. The proposed construction is to consist of a single family residence with an attached garage that are to have a total surface area of 2,770 sq. ft. (0.062443 Ac.). The proposed driveway, patio and other hard-scape are to have a surface area of 2,215 sq. ft. (0.050849 Ac.). The surface area of the remainder of Lot 2 is to be landscaped and consists of 2],675 sn. ft. (0.497589 Ac.). The tota] lot area is 26,610 sq. ft. (0.6109 Ac.) The �veighted percent imperviousness for proposed improveinents on Lot 2 is calculated to be 16.69%. The original design of the subdivision detention pond considered the weighted percent imperviousness for the developed subdivision to be 90%. Therefore, the existing detention pond capacity is more than adequate to accommodate the proposed house, garage and pavement on Lot 2. I sincerely appreciate your time and consideration in the review of this project. If you should have any questions, please feel free to contact this office. Respe ully Submitted �,r� ..r ���+y ...r�� .. f �f ./l�z-- Dennis R. Messner, .E. cc: Randy Whitman Enclosure 'y�� � t �''f � I +`� 1. � C3�/n, ���C�. � � _ o , ,� an��y •`� �: � � . � ; ,�; � l 4 ;tA"� 6��3 :�`� � .���.-,` �uy-Ij"�� ,'�t`�-����.�!-��I'IVJ•�•4a^+ ���� "'y ,?hS.t'`{�rVfa'L � 2015 Buena Vista Place * Telephone: (970) 461-3501 " Loveland, Colorada 80538 Area-Weighting for Runoff Coefficient Calculation Project Title: LOT 2 WHITMAN STORAGE FACILITY Catchment ID: PROPOSED % IMPERVIOUSNES Illustration Instructions: For each catchment subarea, enter values for A and C. Subarea Area Runoff Product ID acres Coeff. A C* CA input input input output Pasture 0.00 0.00 0.00 Pvmt 0.05 90.00 4.58 Roof 0.06 90.00 5.62 gravel 0.00 0.00 0.00 landscape 0.50 0.00 0.00 corral 0.00 0.00 0.00 Sum: 0.61 Sum: 10.20 E�D: low I}irection � Ca�c�m e� Ba�wAau�y Area-Weighted Runoff Coefficient (sum CA/sum A) = 16.69 *See sheet "Design Info" for inperviousness-based runoff coefficient values. EXIST'A' Q2, Weighted C 6/26/2017, 5:04 PM Curb &. Gutter b ' Sidewalk � : �1 8---�� 12' �-----�69.6� ' 89'�4 00" ' Pa�w � � � . .,. - — rainage 100.03' � It ment, b ^ . x � .� E t 6' Chain,�.Fen e.• � 7.5' Drainage� I - �� Exietfng �' 8 0� �� QaUtiltty Emnt. . . South Fort 1}irw '' �.0' n LOT 1 so� c�� � � o� RoW Ea en1 < � � � � ERCIAL (C). j� �= � � N � 9. a =� r z mo `' ` II ' � m � Garaqe m n q • / � F.F. Elev. � : rI` � 1. , �4980.a0 3 `_ '•l y ��� ' a Exiating Residence ' . '. •�' : a F.F. �ev.=4985-9 ' � � 0• I 1�, N e �•.�. , � < S Reaidence � Fm . /' , � F.F. �ev. m v . /O • � =4980.00 - ^M o � . �/�h DRIVEWAY o � 9 o c°i /�� � a' g . �•x: o: N: o. Z � o � � . � /�k�pr n •7 �° � � o 6 a � � �l�� � � . Exisfing Lawn a� �. Masbnry Woll roge � � 1, I�. 70.5' � Limit of � 3.s 1� isti�rbance � ; ��a99�,� � l � .... � LOT 2 � � . Z—f O �� LOW DENSITY RESIDENTIAL (RL) �� � Natural � zo.00' � Feat4�e Buffer / V / �• ' : �' �6 � � j. ::i M. " . .... : � M! b Limit o ' � � � / . J. ' Development i�'.,''` M Existin � 9 � � D.rainage / Fence 1 � � � �� / Easement��� ��.� �Propert: � � � . � fs � ^a . ;'./: on �Existing 9� Tall � �Zo.00• � : ;7 ; � `tSolid Fer�ce—�� . �. . . 1 � .;�, �m / � . _h � � �d • � av . �� . . � � . .. ' .. .. . r: : . U m . . . � .� • ; i �,'�' n Exi.sting. 10" .�'r6. � .. � � • ./ ACT A �.� n �• � m � 0 � Sanitary Sewer Line: � . . z . � � . . � \. o -� .. m �n x + ; •o � X J (� rt 7 � � O 7 .N+ � � N N ��� � � p r ! � a:. l' � ��� Q �� �� � �� � d �O�O� � Q 4� ° a V. �. O a T � s• gDFA•,�•• .� � A p � O� 3 �• V10 �J� � �• 1 ' 1 (/� � • l� ,Y•v�•�.'Q � m •� £ m ,� �,� �.� a .� Z ` • `r Iv � � � � m "' a � c a m�a N�-a' o a � �:'3-� ' . m o ' o o a, o t no � a � o r • a� � � m om om m m (�'.A �t � � orn � rt� y N �� p� I S� •� �� � 7 M O ��• � � m� mm v � m Vj w._ •.,� o o � m o m x• na o'-`• ' Y C T. � o� o 0 0�. � o � m. � c r Y .-. �> > A � � �� � m � .. . .. . .- - • � a � a - - I� m � � � � � CLIENT: � N� �.. RANDY WHITMAN DENNIS R. MESSNER, P.E. � � o� Greding dc Tempornry Erosion Coatrol Plan fot' Re�dence on Lof. 2 Civil tneerin Caneultante I ' f+'9 9 �� � Ahitman Storage Facility Fort Celllns. Coleredo 2075 Bueno Y�ata Place, Lweland, CO 80538 Tda:(870�61-3501 Dennis R. Messner, P. E. Consutting Civil Engineer Dan Mogen, P. E. Stormwater Utility Service Center 700 Wood Street Fort Collins, Colorado 80522-0580 July 28, 2017 Project No. 1032-GRD-17 Re: Building Permit # B1702249, Lot 2, Whitman Storage Facility, Fort Collins, Colorado Dan, With regard to your review comments dated 7/28/2017, I have the following response: The house being constructed is designed specifically for the owner's 80+ year old mother who has mobility issues. I have not designed any step down areas along the southern side of the garage or western side of the house since these are the areas of primary access and are to be a concrete surface. The design has been performed to essentially have the garage doors and the entry door at the same elevation (4980.00). The concrete slab is to slope southerly away from the garage doors at a maximum slope of 1/4" per foot to met ADA standards. The driveway at the west side of the garage also has a cross slope to meet ADA. I do feel that the desigr► as performed meets the intent of the City's grading requirements and am willing to verify that at the time of Grading Certification. I sincerely appreciate your time and consideration in the review of this project. If you should have any questions, please feel free to contact this office. Resp �ffully Submitted, f '� % ���� Dennis R. Messner, P. E. cc: Randy Wlutman Enclosure 2015 Buena Vista Place " Telephone: (970) 461-3501 ` Loveland, Colorado 80538