Loading...
HomeMy WebLinkAboutGrading Plans - 05/11/2017Engineers Planners SurvFyors Geotechnical May 2, 2017(revised May 8, 2017; May 10, 2017) Project No: STRATH-3F3C-02-623 Landma.rk _o�� ar� 97'�-e�7-c�85 ��.: _. 35„-�79-5_�_ =.x 9�;;-55--5293 N t^: .y �__ �^:�s= ->_-.-owe: o:.., _cv_-��...... �..lora..,. oJ�37 DRAINAGE MEMO Lots 11, Morger Smith Subdivision (a.k.a. 132 North Shields Street), Fort Collins, CO To Whom It May Concern, B1701080 Accepted 5/11 /2017 DM The proposed of the grading plan for the above mentioned address is to protect the proposed structure and adjoining lots from stormwater runoff and verify the placement of the structure above the current floodplain (elevation 5,022.8 — NAVD88). The existing subdivision (Morger Smith Subdivision) was established around the 1900's and the grading for the subdivision will never be able to apply to current drainage and grading standards. The lots are typically configured as a"Type C" grading which allows for the drainage from the front of the lot to flow towards the rear of the lot. The existing lot lines on the north and south are at 1.25% and 1.46%, respectively. These are existing established lot lines with an alley running along the north and east sides of the property. Grades cannot be changed without impacting other residences adjoining the alleys. The proposed structure was located to be out of the defined floodplain and maintain the front and side yard setbacks. The closest corner of the proposed structure to the floodplain is 0.54' from the floodplain demarcation line. In addition, the top of foundation elevation of the new structure, was set at 5,024.8 which is a minimum of 2.0' above the floodplain elevation. It is also intended to have an approximate 9 1/z" of foundation reveal which provides for the grade adjacent to the structure to be 1.2' (minimum) above the highest floodplain elevation. The grades away from the house is approximately 17% to 22% with the flows running into the side yard swales. The runoff from the front of the structure will flow to the side yard swales and then flow to the rear as has historically occurred. This proposed structure should not change the historic drainage of the surrounding areas nor impact the adjacent properties. Stormwater runoff will flow around the proposed structure on either side and will reach the rear of the lot as historically has occurred in the side yard swales. The top of foundation, adjacent finish grades, spot grades, side yard swale flowline grades, and elevations shown on the Plot Plan/Grading Stratton Builders 132 N. Shields St. Lot 11, Morger Smith Subdivision Project No. STRATH-3F3C-02-623 Page 2 of 2 Landmark Plan, dated and signed May 10, 2017 and the information in this memo should be used to perform construction layout of the structure, side yard swales, and the final grading for the site. All gutter down spouts should discharge to either the front or rear of the structure. If you have any questions, please feel free to contact our office. Sincerely, LANDMARK ENGINEERING, LTD. ��� � � ' `� � ^L<� `✓ `/ ' L Rodney� . Harr, P.E. Director of Engineering \ ���ti,u � � i ►�u,i��� �`��<��,DD REC� �''. .,, ....., . .. ��E,Y PR. ,� ,� �,'� ✓ �' L = / = 26$ 7 = � ' �- _ . � /��� �, _ . �.' o � -�� , ..i,' FS,']!.!,d/�• �� `. '�i., S/pN A t �-�������� �iii�rninu������ PLOT PLAN LOT 11, MORGER SMITH SUBDIVISION 132 N. SHIELDS STREET, FORT COLLINS, COLORADO xXxX.xx = LOT CORNER ELEVATION PER GRADING PLAN XxX.xx X= EXTERIOR GRADE ELEVATION PER GRADING PLAN T.O.F. = PROPOSED TOP OF FOUNDATION ELEVATION NOTE: FINISHED GRADE AT FOUNDATION SHALL BE 8" LOWER THAN T.O.F. LOT 11 8,547 SQ. FT NORTH SHIELDS STREET EXISTING 4' SIDEWALK TO BE REPLACED TO AN H' SIOEWALK NORTH EXISTING 4' SIDEWALK PROPOSED 8' SIDEWALK ll � � �,.,ti � IS' gIB. � r ,. � }�� I � uY .�I �� � � I �ti I O �' V p A m� O > II�D_ —/� . Dm�u;� �1 ��I m�AOZrn O sl �p~z l(� ,Z � m rn � rn� i � _" SIDE YARD SWALE DETAIL 3.5' 6 5' EXISTING�FDN GRADE AT F.G=24.0 � SWALE ELEV. PER PLAN ,�,;�,,,�������r,�;;,, � .; ' J���� RE;�`���•��'7 . ..��y �� ` � � � � f _ zs��% - " ��f..,� /,` /!;�'�'✓�,\\r r��� e,. �`'%-ss/O N Al ���.�`�� 'qqrl��i �1;��1��,` 4' SIDEWALK 8' SIDEWALK .�,. �. ««,��. r� � oqws�mE�u a � � _,� µo EXiFND j(' ccaveR m I � RE9DENC£ NEW EfQI IH5�E Ieann�nw aw 4 pTT STN1DAfmS � � � f0 ' W �I � , • � 0 o q` I �\ ' �i. �aw - mg Y� �g x�;� Z g'� � � � _, �g� �� ia�� ll �� � F�i � i� � > bl Ill m I I � ��I I� - � ��I I�x ' "QI I�s I I o I I Nlll I � � � � u� i iu lll 1I L- 5 HFM gfB�IX - J l ALLEY � i —� ����s.��� V WT. NflV {' SANIiMY YNEF 4FNCE MM_ 2T Ap'E NIM QfIN Wi. ec iwro rxsuNc KP NNN E AT APPRO% &S' IN ocrm (� ocwy u� f.��<o D r r-- �m � � % NorEs: 1. THIS PLOT PLAN IS BASED ON INFORMAlION PROVIDED BY THE OWNER/CONTRACTOR. THE " OWNER/CONTRACTOR SHALL VERIFY ALL LOT DIMENSIONS, SETBACK INFORMATION, EASEMENT WIDTHS, GRADING ELEVATIONS AND THE PROXIMITY TO EXISTING STRUCTURES WITH THE GOVERNING - AUTHORITY AND OR COVENANTS. 0 2. DIMENSIONS SHOWN AROUND THE PERIMETER OF THE STRUCTURE ARE TO EXTERIOR FOUNDATION CORNERS. � 3. THE CONTRACTOR SHALL VEPoFY ELEVATIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY VARIATION TO THIS PLAN SHALL BE REPORTED TO LANDMARK ENGWEERING LTD. IMMEDIATELY. 0 4. THE CONTRACTOR SHALL NOT ENCROACH ON ADJACENT PROPERTY WITHOUT PERMISSION FROM = THE AFFECTED PROPERTY OWNERS. 5. PROVIDE AND MAINTAIN POSITIVE DRAINAGE AWAY FROM ALL FOUNDATION WALLS: SEE _ DRAINAGE MEMO. TITLE: LOT 1 1, MORGER SMITH SUBDIVISION % Landr�na�"�� CLIENT: STRATTON BUILDERS SCALE: 1"=30' � Erigir�eer inc� � 3521 Wesi FlsenhowF:r tllvo.. L�veiunU. Caloratic 80537 ��9�0� 66�-b�e6. ro. F�ee (866J s�9-b�s�. F�. i9�o� 66�-629a DATE: 10 MAY 201 7 JOB #: STRATH-3F3C-02-623 I e n d m r k I t d 4 This document is an instrument of prafessional service af Landmork Engineering Ltd. (LE.L.). Landmork shall, to the fullest extent permitted by low, be held harmless and released of any damage, liability, or cost arising or allegedly arising out of any modification, chonge, or reuse nf this dnr.ument hv nthers. � ����,��....� . r•i,�����. � . -:.�.....�,..� . n �. ����... �•. � ;..���.,. �,�,�._:.� April 28, 2017 (revised May 8, 2017) Project No: STRATH-3F3C-02-623 i - K �r Landmark __.. _ - t i I�. 'I � 7� • I I I i. . � ,�, ,.,�. � � � . � � � � , �� . -i w<<_ i- ., � �..��� i�,i,. , i.,,_,� .. _r�i„�_�_� zo,.i-r UTILITY MEMO Lots 11, Morger Smith Subdivision (a.k.a. 132 North Shields Street), Fort Collins, CO To Whom It May Concern, The proposed water and sanitary sewer service connections for the above mentioned address should tie-in to the existing City of Fort Collins water main in North Shields Street and to the existing sewer main in the alley running on the north side of the proposed structure. The existing subdivision (Morger Smith Subdivision) was established around the 1900's and there is an existing water service stub from the main located in North Shields Street. However, an interior meter for residential service line will need to be installed in the northwest corner of the basement of the proposed structure in accordance with the City of Fort Collins standard details, a copy of each is attached to this memo. The sanitary sewer service line shall be connected to the existing sanitary sewer main located in the alley to the north of the proposed structure. Based on information provided, the basement cannot be served with sewer by gravity and a grinder ejector pump will be required for all facilities in the basement. It is recommended that these be kept to a minimum. However, the main floor and upper stories can be served by gravity. It is suggested that laundry facilities be kept on the main floor. The service line shall be 4" diameter SDR 35 PVC installed at a minimum of 2% with a clean-out outside the structure and tie-in to the main using a tapping saddle with bands similar to the one in the attached detail. The sewer main will need to be "wet tapped" by the City of Fort Collins or a contractor authorized by the City to make the connections. The line is reported to be 6" VCP and requires special tapping requirements. If you have any questions, please feel free to contact our office. Sincerely, LANDMARK ENGINE6RING, LTD. /-, �i �;�t l �' i l� Rodne r A. Harr, P.E. Director of Engineering \�����i�ui�ri►,i�i ,�.��• p R E �/ ��' � /` � ...... ,�''� ,�; -' Y �� •, �j ,,, , _ _ 26�57 .7 = : o,�, �� y�/,�� . �y, ; � �; � •••....•• V��'�� �'�%,sri�N At �-��.���, .,������rinii������ attachments CUT 4 INCH CROSS IN FACE OF CURB PAVEMENT CORPORATION STOP FOR 3/4 AND 1 INCH SERVICES 45' FOR 3/4 AND 1 INCH SERVICES � - -i- - - - LCORPORATION STOP FOR 1 1/2 INCH OR GREATER SERVICES WATER MAIN GENERAL NOTES OISTANCE VARIES �f fT. CURB BOX 54 INCH MIN. 66 INCH MAX. CURB STOP Iw z J H Z W � W � Q I w �' 0 � � � w d 0 � � FINAL LANDSCAPED GRADE 1. Use direct tap (as shown) for 3/4 inch and 1 inch services unless water main is PVC, in which case, use a tapping saddle. 2. Install 1 1/2 inch and 2 inch services with tapped tee and corporation stop at time of construction or use a tapping saddle. 3. Locate curb box and meter pit according to the approved utility drawings, 4. The City is responsible for maintaining the water main, corporation stop, and service piping up to and including the curb stop. The owner is responsible for service from the curb stop, including the outlet coupling to the building. 5. No couplings allowed between curb stop and meter setting. 6. Use type K copper for the service from the corporation stop to a minimum of 5 feet past the meter pit. 7. No landscaping (shrubs, boulders, etc.), retaining walls or fences allowed within 4 feet of the curb stop and meter pit, and no trees within 10 feet of curb and meter pit. 8. All residential water service shall be installed in the center of the lot unless otherwise approved by the Utility. 9. All water and sanitary sewer service shall have a minimum horizontal separation of ten feet. CURB, GUTTER AND SIDEWALK �� CIU���FS RT �A� S' TrrLa OP DRAIfING R4/12/11� �.wt FIELD OPERATIONS i TYPICAL `'PATER SERVICE /�� �..�Jl��ri '�J' p,0. BOX 580 � DETAIL FORT COLLINS, C0. 80550 II 11 (970) 221-6700 SUPPORT OR BRACING REQUIRED FOR WATER SERVICE LINES (SUGGESTEO METH00) STANDARD 2 IN. DEEP RECESSED � ELECTRIC BOX (SEE NOTES 2& 3) MOUNT WITHIN 4 FT. OF ELECTRIC METER AND 48 IN. TO 66 IN. ABOVE FINAL GRAOE (VERTICAL INSTALLATION RECOMMENDEO) SHUT-OFF VALVES WITH HANDLES ATTACHED TO INLET AND OUTLET OF COPPERHORN- 1/2 IN. OR LARGER ELECTRICAL CONDUIT (SEE NOTE 2) COPPERHORN (SEE NOTE 4) �N 3 ��� '�P�� FRO WATER SERVICE J � �� . rU' � r ���� ii �i \�`.� � � l� �� ���� I � . �r�`� GENERAL NOTES: PRESSURE REDUCING VALVE (IF REQUIRED BY PLUMBING CODE) 48 IN. MAX. FROM BASEMENT FLOOR NOT TO SCALE 1. PROVIDE CLEAR AND UNOBSTRUCTED 2 FT. BY 2 FT. MiNIMUM ACCESS TO THE COPPERHORN AND SHUTOFF VALVES. 2. ELECTRICAL CONDUIT WILL BE 1/2 INCH OR LARGER ELECTRICAL METALLIC TUBING ONLY, INSTALLED IN CONFORMANCE WITH ARTICLES 347 AND 348 OF THE CURRENT NATIONAL ELECTRIC CODE. CONDUIT MAY NOT EXTEND MORE THAN 75 FEET BETWEEN JUNCTION BOXES. CONDUIT WILL BE CONNECTED TO A RECESSED EXTERIOR ELECTRICAL BOX MOUNTED WITHIN 1 FOOT OF THE FRONT CORNER OF THE STRUCTURE ON THE SAME SIDE AS THE ELECTRIC METER AND TERMINATED WITHIN 6 INCHES OF THE COPPERHORN. NO FLEXIBLE PVC CONDUIT ALLOWED. 3. ALL JUNCTION BOXES MUST BE INSTALLED NO MORE THAN 96 INCHES ABOVE THE FLOOR AND HAVE OPEN ACCESS. 4. COPPERHORNS WILL BE INSTALLED SO THAT METERS ARE IN A HORIZONTAL POSITION. 5. A SECURE SUPPORT IS REQUIRED FOR COPPERHORNS. 6. JUNCTION BOXES SHALL NOT BE INSTALLED IN ATTICS OR CRAWL SPACES. 7, METERS SHALL NOT BE INSTALLED IN CRAWL SPACES. � CI�T�FS RT nA� S II T�77,6 OP DfGRlNG Collins FIELD OPERATIONS STANDARD INTERIOR SETTING FOR P.O. BOX 580 3/4 IN. AND 1 IN. WATER METERS FORT COLLINS, C0. 80550 f970) 221-6700 REVI32D DATE: 4/11/11 DETAIL 14 fhis document is an i^stru��ent cf professional sarvice of �andmork Englneerir�g Ltd. (LE.L.). Landmark shall, to the fullost ex!ont permitt��d by law, be held harn�less and reieased of any domage, liability. or cost arlsing or ollegedly arising out of any modificaticn, change, or re.ise af this document by others.