HomeMy WebLinkAboutGrading Plans - 12/22/2017A DVAN C E D ENGINEERING, LLC STRUCTURAL DRAINAGE DRAFTING December 8, 2017 NIr. Scott Fetters HighCraft Builders 429 S. Howes Street Ft. Collins, CO 80521 LOT 21 & W 19 FT OF LOT 22 BLK 179 Gillettes B1708394 & B1708395 Plan accepted and permit released 12/22/2017 DM RE: Site Drainage at 602 E. Elizabeth Street, Ft. Collins, Colorado Advanced Engineering, LLC Proj ect Ntunber 1011-224-01 B Dear Mr. Fetters: We have consulted with you regarding a remodel and addition project that is proposed at the above referenced site. The home is to have a small addition and interior remodel, the detached garage is to be replaced with a new detached garage. Our office has reviewed the existing and proposed drainage conditions at the site. This review included visual observations, a limited elevation survey, and area calculations. The purpose for this review was to evaluate the impact of the proposed proj ect on existing drainage conditions. Based on our review, the impervious area at the site will be increased by approximately 17% above existing conditions. It is our opinion this increase is negligible and will not require mitigation. We feel the existing drainage will continue to function as it has historically. Based on the survey information, we recommend the monolithic garage slab/foundaxion be consiructed with the finished floor at an elevation of 4988.9 feet or higher. The recommenda.tions and conclusions presented in this letter are based on a visual review of portions of the described site/structures, your plans and your directions. Our review was limited to the items described in this letter, and is not intended to cover structural, mechanical, electrical, environmental, mold, or architectural features of the site/buildings. Discrepancies or deficiencies revealed during construction should be brought to the attention of the engineer. Our office has not performed any engineering analysis of the existing on site or off site drainage conditions, unless noted otherwise. Thank you for the opportunity to serve you. If you have any questions, please feel free to call. Sincerely, , �.tl.���: -`� �S��r''% �rwrd Advanced Engineering, LL,C�, �R�ON E. ������%,� -� � _ �-%�' � r� ; p ! � = 33739 ; ; = �. _ � 1 Jason E. Baker, P.E. �';-, p,�"•l,Z- �-1 ���.�'�: Presiderit %��`'�i,,;'�ONA ; �„`,\ ````��. nun� 229 12"' Street SW, Loveland, Colorado 80537 Telephone 970-278-1909 � � PRESERVE EX[STING MASONRV BLOIX I WALL E%CEPT WHERE REQUIRED TO CONSTRUR NEW GARAGE , � (E) FENCE W � W � � � _ L 7 � � F '�°.w� (N) CONCRETE AREA OF GARAGE WITH 5 7'-6" CEILING � HEIGHT: 85 SQ. FT. m (N) FENCE (MATERIAL TBD)- � z 0 "a " ALLEY J L I 36 �"i �CTUALGARAGE I I � I < I � I Q � � � �� a / � I _ �;� , ' / ��� I �Q�B •9 � I \ x �!�' 8g.y : i I ■ � � 14'-0"t I I�IEWE%POSEDAGGR ATE - � LA ING & GRADE-LEVEL AT10 I I Irf�� �i r. :■ ■ x I � O � I 17• 0" �� I I � � � � /�Te� pF � T �� O t I 602 EAST ELIZABETM STREET IEXISTING 2-STORY RESIDENCE I � � �—_ I � I �` I I � , __-__.li . —__� O � �� � �x� 5��� a,a„d 5��� EXISTING NON-CONFORMING SIDE SETBACK n C'�'4 `�' �- � � t I � i 15' REQ'D CORNER SETBACK � �� � I • � �y � � � � m , o —�� � , Z � O o ° � � � �,_._...�.. .�._....._,.� ba2,� ELIZABETH STREET Y m � < v"'+ u � ¢ '^ AREA OF GARAGE WITH > 7'-6" COLING HEIGHT: 507 SQ. Ff. (N) FENCE WITH LOCKING GATE -6'�6' MIN. SIDE SETBACK PER HOMEOWNERS E7(ISTING GARAGE + SHED DEMOLISH EXIST. FENCE NEW FENCE AT PROPERTY LINE BY OTHERS NEW LOW PIANTER BED ACTUAL 9DE SETBACK STAIN (E) CONCRETE PORCH AND STAIR (N) STAMPED CONCRETE DRIVEWAV AND WAIK DEMOLISH & REPAIR (E) CONC. CURBS AS REQ'D 5' REQ'D SIDE SETBACK /�!l s� s � � l' ��1-�-�,M Advc�� �����a.r�� �tc��l—z�-�--otg �a� � 2.— 8�— ZC� I% �a "�AD i �J G-� l�U�t1 ' 12— ( 4-?_c.� ( 7 1"= 20'-0" (-� �� i.�C:��.% � t,�� � c�i e,r S �/� Dan Mogen From: Jason Baker <jason@advancedengineeringllc.com> Sent: Thursday, December 21, 2017 5:31 PM To: Dan Mogen Subject: RE: 602 E Eliz drainage/grading Dan, Total lot 10,503 sf Exist impervious 4271 sf (41%) Additional Impervious 971 sf New total impervious 5242 sf (49%) The addition to the house is at a spot that is currently concrete pavement, so no increase there. The new garage is only 8 sf more than the old one. Most of the new impervious is the concrete drive on the east side, which will have a V-pan down the center draining to Elizabeth. The drive is currently compacted dirt/gravel, which was not taken into account in our previous calculation that showed a 17% increase. As you requested, we revised this calculation and the existing drive was taken at 40% impervious, resulting in an 8% total increase in lieu of 17%. The drive currently has no slope next to the house, bad for this house and the adjacent neighbor (my first visit to site it was raining and it was standing water). With the new drive we can slope it out to the street better and improve drainage for both houses. It is also worth noting that the original house had almost flat roofs, which were overframed with steeper pitch at some time in the 80's. As part of the remodel project, the roofs are being lowered back down to original slope, so the time of concentration will be increased there (especially for snow) and offset the decreased time at the driveway. Let me know if you have other questions. Thanks, Jason E. Baker, P.E. President/Principal Advanced Engineering, LLC 229 12th Street SW, Loveland, CO 80537 970-278-1909 office, 970-690-4616 cell iason@advanceden�ineerin�llc.com From: Dan Mogen [mailto:dmogen@fcgov.com] Sent: Wednesday, December 20, 2017 2:45 PM To: Jason Baker Subject: RE: 602 E Eliz drainage/grading Jason, I have just one question at this point — what is the net change in impervious area? I see where you've indicated ^'17% increase; what does that equate to in square footage? Thanks, Dan Dan Mogen, EI, CFM Development Review Engineer Stormwater Engineering & Development Review Division City of Fort Collins Utilities (970)224-6192 dmo�en@fc�ov.com From: Jason Baker [mailto:jasonCc�advancedengineeringllc.com] Sent: Tuesday, December 19, 2017 9:00 PM To: Dan Mogen Subject: 602 E Eliz drainage/grading Importance: High Dan, please see attached as you requested. Let me know if you need more. I'll be fully involved thru the construction process, and will ensure they improve the drainage as best possible where possible. HighCraft does top quality work and the site will end up far better that before, with no impact or reduced impact on the one neighbor (east side). Thanks, Jason E. Baker, P.E. President/Principal Advanced Engineering, LLC 229 12th Street SW, Loveland, CO 80537 970-278-1909 office, 970-690-4616 cell iason@advanceden�ineerin�llc.com