Loading...
HomeMy WebLinkAboutGrading Plans - 10/05/2016Grading plan and drainage memo accepted 10/5/2016 DM Enc��r ,•�rrc- F'lanners Surveyors GcotFcFisiic��l Date: September 8, 2016 (Revised September 28, 2016) Project No. STRATH-SF8D-03 Landmark �ov�i_,., 97C-557-5235 .,,,.- �_ 555-�?9-5_�� DRAINAGE MEMO -'Y ���-�5'-�'-�� v: •r,� ��ri . Lot 3, Block 7, Buckingham Place S�bdi,y�uor�5�� ��.r:�r s�� �,Y�:7;,�. ��,�, ��� 3�;;, (AlCA) 209 3'd Street, Fort Collins, CO To Wham It May Concern, The purpose of the grading plan for the above mentioned address is to protect both the existing structures and proposed new structures. The existing subdivision (Buckingham Place) was started around 1900 and the grading for the subdivision will never be able to apply to current drainage and grading standards. The proposed top of foundation of the new structure, was set to have a minimum 8" of foundation reveal and 6" of fall away from the foundation to the high point in the middle of the lot. Then, at minimum the grading should be 1.5% around the south side of the structure to the east side of the lot or front of the house to protect the new proposed foundation and basement from water. Around the north side of the structure a swale should be installed at 1.0% fall to the front of the house on the east side to protect the new proposed foundation and basement from water. With this high point set and the flow towards the front this should protect both existing structures and proposed structure from the drainage. The high point is set close to the finish floor elevation of the two existing structures but with the swales built with the percentage of flow, the swale should be below the finish floor elevations when close to the existing structu�es. The top of each window wells should be held at the 4900.00 elevation. A retaining wall should be placed on the subject property along the property line the length of the new structure. The swale shal! be place between the window well and the new retaining wall. Both North and South property lines are currently fenced and said drainage should follow a swale built on the subject property with the current fence line and property line being unchanged. This in affect will not change the historic drainage of either neighbor and insure the site drainage on either side of the subject property will reach the street and not the neighbors property. The grades shown on the grading plan are to be the flowline of the proposed swale with the top of the swale at the property line and the foundation being higher to protect both the foundation and the current property lines. (See swale details for both protecting the foundations, property lines and existing fences. Sincerely, LAfjtQMARK ENGINEERIK6, LTD. � ��, �� � ���r. ''Rodney �I� arr ' Director of Engineering �:ur,r�i , . � %i . ::: ;� i��i��' '� ` • J .', �'. ,-: ' ,.. ... ,, � - ��"". `/ ,�� _ ` 26;- - y _ = /J �j //!� aJ � '�� • C�'��� L�/ \ `` F ; r/� \�\ ��''%,`,y,s�0 N A� �-����`. i GRADING PLAN LOT 3, BLOCK 7, BUCKINGHAM PLACE 209 THIRD STREET, FORT COLLINS, COLORADO LOT 3 6,350 SQ. FT W O O O O O O Z S 89'47'57" W 64.3 � � � p EXISTING v GARAGE '- F.F.=4899.0 20.0' 1 �aN�. 16.9� 1 CON h� �� 127.00' . °'� , �'� J,� ;� � o // 18.54' 1.Oy 0 ; o 3 � � PROPOSED q� HOUSE a .00" T.O.F.=4900.00 a VANDOW WELL o T.O.F.=4900.00 \\ ci 1� �00' o.i �" EXISIING � CONC. m HOUSE o 12.67' � � � F.F=4B98.8 18.9' � � W/M' 'oo = 67.7' in J 5.31' g S 89'47'57" W se9 76.8' 127.00' 9 � GRAPHIC SCALE �� L=6.80 � R=4.33 20.21' O � O � � W C L O O � O O 20.05' � O Z � OJ7' 1.6R �� �� 0 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. SWALE DETAIL SWALE DETAIL SWALE DETAIL EXISTING RETAINING PROPOSED PROPOSED �NCED PROPOSED �yALL FOUNDATION POUNDATION FO ON PR �NE �• F ON pROPERTY OR WELL FL R FL � GRADING NOTE: THE SITE HAS EXISTING STRUCTURES AND IS IN A LOCATION WHERE GRADES AND ELEVATIONS ARE ALREADY ESTABLISHED AND DO NOT MEET � CURRENT STANDARDS. THIS PLAN PROVIDES ELEVATIONS TO KEEP NEW � CONSTRUCTION ELEVATED TO HAVE DRAINAGE. THE REMAINDER OF THE $ SITE WILL BE AT HISTORIC DRAINAGE. SPOT GRADING SHOWN ON PLAN WILL BE CREATED WITH A SWALE ON THE SUBJECT PROPERTY AND NOT o AFFECT NEIGHBORS CURRENT GRADING OR PUSH DRAINAGE ONTO u NEIGHBORS PROPERTY. NOTEs: 1. THIS SITE PLAN IS BASED ON INFORMATION PROVIDED BY THE OWNER/CONTRACTOR. THE OWNER/CONTRACTOR SHALL VERIFY ALL LOT DIMENSIONS, SETBACK INFORMATION, EASEMENT WIDTHS, GRADING ELEVATIONS AND 7HE PROXIMITY TO EXISTING STRUCTURES WITH THE GOVERNING AUTHORITY AND OR COVENANTS. 2 DIMENSIONS SHOWN AROUND THE PERIMETER OF THE SIRUCTURE ARE TO EXTERIOR FOUNDATION CORNERS. 3. LANDMARK ENGINEERWG RECOMMENDS A MONUMENTED LAND SURVEY (BOUNDARY SURVEY) BE COMPLETED BEFORE THE BUILDING OF ANY NEW STRUCTURES. �,•.u�:uui,i�;;, - �.�� . ;;;0 REG�. .,; , , _ � ''c�;n . � ,� ., `�'• ��'���Z%, � �^ ....� - � �, A� � _- , •1,,,,,,\., REVISED 28 SEPT. 2016 TITLE: GRADING PLAN � Landrr�a�"f!�� CLIENT: STRATTON HOMES SCALE: 1"-20' � Engineer irig � 3521 West Eisenhower Blvd., L�veipn 1. Colorado 80537 � �9�0� ee�-bzee . To i FreP �ebe1 :��v-s2sz . �ox �9�07 be�-s�ve DATE: 1 6 MAY 201 6 .)OB #:STRATH-5F8D-03-622 .ie�am �kiie � This document is an instrument of �rofessional service of Landmark Engineering Ltd. (L.E.L.). Landmark shall, to the fullest extent permitted by IaW, be held harmless and released of ony damage, liability, or cost arising or allegedly arising out of any modification, change, or reuse of this dncumr.nt hv others.