HomeMy WebLinkAboutPOUDRE GARAGE - BDR160007 - SUBMITTAL DOCUMENTS - ROUND 2 - PHOTOMETRIC PLANNORTH C.O. ELEC BRKR AC AC E 20' ALLEY REMINGTON STREET (100' PUBLIC R.O.W.) OAK STREET (100' PUBLIC R.O.W.) 2 STORY BRICK 1 STORY BRICK 1 STORY BLOCK RAMP W/ HANDRAIL ELEC VAULT T T Scale: 1"=10' 0 5 10 20 REMOVE EXISTING OVERHEAD ELECTRICAL FEED. COORDINATE WITH CIVIL REMOVE EXISTING WOOD POLE AND POLE MOUNTED FIXTURE. COORDINATE WITH CIVIL EXISTING FIXTURES TO BE REFURBISHED, SEE DETAILS, SHEET E-102 REMOVE EXISTING UTILITY METER AND HOUSE PANEL REMOVE TELEPHONE AND CATV FEEDS 1 1 1 REMOVE EXISTING TELEPHONE PEDESTAL. COORDINATE WITH CIVIL 1 REMOVE EXISTING WALL PACK AND ASSOCIATED SURFACE MOUNTED CONDUIT. FLAG NOTES - THIS SHEET ONLY REMOVE WOOD BASE PLATE AND REPLACE WITH SHEET METAL COVER REFURBISHED AND PAINT DARK BRONZE METAL ENDPLATES CLEAN GLASS LENS REWORK EXISTING INCANDESCENT LIGHT SOURCE AND REPLACE WITH LED MODULE EXISTING FIXTURE TO BE REFURBISHED NTS 1" = 10'-0" VAULT ELEC 20' ALLEY REMINGTON STREET (100' PUBLIC R.O.W.) OAK STREET (100' PUBLIC R.O.W.) Scale: 1"=10' 0 5 10 20 NORTH NEW METER STACK. MAINTAIN 5'-0" SEPARATION FROM NEW GAS METERS APPROXIMATE LOCATION OF NEW MAIN TTB T T RECONNECT TELEPHONE AND CATV SERVICE. COORDINATE WITH CIVIL 2" CONDUIT FOR TELEPHONE AND 2" CONDUIT FOR CATV AA BB BB AA AA AA BB EXISTING FIXTURES TO BE REFURBISHED, SEE DETAIL, THIS SHEET P P P BB AA AA T NEW SUBMERSSIBLE UTILITY TRANSFORMER MOUNTED IN UNDERGROUND VAULT. COORDINATE WITH CIVIL NEW TELEPHONE PEDESTAL, COORDINATE WITH CIVIL ....................... TYPE 'AA' 1" = 10'-0" Electrical Site Plan - New 6801 W. 20th Street, Suite #212 GREELEY, COLORADO 80634 GREELEY: (970) 330-3266 FACSIMILE: 1 (888) 551-1062 & ASSOCIATES, LLC ELECTRICAL ENGINEERS - PLOT DATE A A 1 2 3 4 5 MMMM MMMMMMM ELECTRICAL ONE-LINE M EXISTING WEATHERHEAD ON BUILDING EXISTING UTILITY METER EXISTING HOUSE PANEL 150A MCB EXISTING EXISTING REMOVED EXISTING POWER POLE ON PROPERTY TO 120/240V, 1PH, TRANSFORMER BANK AT END OF ALLEY EXISTING POWER POLE IN ALLEY TO REMAIN. LOW VOLTAGE CABLING ATTACHED TO POLE SHALL REMAIN UNDISTURBED 1 GGGG G 5678910 GGGG 10 10 'H' PNL HOUSE 'R1' PNL RETAIL 600A JJN 600/3 100/3 200/3 200/3 100/3 100/3 100/2 100/2 100/2 'R2' PNL RETAIL 'R3' PNL RETAIL 'R4' PNL OFFICE 'A' PNL 1 BED/ DEN 'B' PNL 1 BED/ DEN 'C' PNL STUDIO 100/2 10 'D' PNL STUDIO 100/2 10 'E' PNL 1 BED 100/2 10 'F' PNL 1 BED GANGABLE GROUP METERING, NEMA 3R, 600 AMP MLO, 200 AMP METER SOCKETS 120/208V, 3 PHASE, 4 WIRE OUT, BRACED FOR 100,000 AIC, METERING AND PANELS SHALL BE SERIES RATED TO ALLOW 10,000 AIC BREAKERS IN RETAIL, APTS, AND HOUSE PANELS. PROVIDE DATA AT SHOP DRAWINGS AND PROVIDE 22 LABELING OF SERIES RATING ON ALL PANELS. MIN 10'-0" 3/4" X 10'-0" DRIVEN GRD ROD 3 BLDG STEEL 3 COLD WATER PIPE 4 N.TS. NEW CAD WELD TO REBAR AIC = 17,926 XXXXXX XXXXX X X AIC =26,000 VERIFY AIC WITH POWER CO, IF FAULT CURRENT EXCEEDS 26,000 NOTIFY ELECTRICAL ENGINEER NEW FT. COLLINS LIGHT AND POWER 120/208V, 3PH, 4W, 150KVA SUBMERSIBLE TRANSFORMER MOUNTED IN UNDERGROUND VAULT T a,b b,c c,a a,b b,c c,a INDICATES PHASE CONNECTION (TYPICAL) AIC = 3,572 AIC = 3,944 AIC = 4,160 AIC = 4,672 AIC = 4,979 AIC = 5,329 AIC = 4,527 AIC = 5,350 AIC = 7,969 AIC = 8,399 AIC = 8,671 UFER GROUND PIPE GROUP METERING ELEVATION FINAL GRADE NOTE: 1. EACH METER MUST BE PERMANENTLY LABELED TO IDENTIFY CUSTOMER ADDRESS. 2. LABEL MUST BE CONSTRUCTED OF ENGRAVED BRASS. 3. FAULT LIMITING DISCONNECTS SHALL BE INSTALLED ON THE LINE SIDE OF THE METER. FUSE SIZE AND TYPE SHALL LIMIT FAULT CURRENT TO THE METER HOUSING TO 10,000 AMPS OR LESS PER THE NEC. 4. THE FUSED DISCONNECT SHALL BE PURCHASED AND INSTALLED BY THE CUSTOMER AND SHALL INCLUDE PROVISIONS FOR A FORT COLLINS LIGHT AND POWER COMPANY SEAL. 5. SEALS WILL BE USED BY FORT COLLINS LIGHT AND POWER COMPANY TO SECURE THE ENCLOSURE FROM UNAUTHORIZED ENTRY BUT ALLOW THE CUSTOMER EMERGENCY ACCESS FOR FUSE REPLACEMENT. N.T.S. SEALABLE ENCLOSURE MIN 7 1/2" MIN 8 1/2" 600/2 MFS MAX 75" MIN 24" BREAKERS SHALL BE SERIES RATED FOR THE AVAILABLE FAULT CURRENT VALUES SHOWN. SERIES RATING SPECIFICATION WHERE SERIES RATING COMBINATIONS ARE SHOWN ON THE PLANS, THE LOADSIDE CIRCUIT BREAKERS SUPPLIED SHALL BE TEST AND LISTED AS A SERIES COMBINATION WITH THE LINE SIDE FEEDER FUSES PER THE PLANS. PANELBOARDS WITH SERIES RATED LOADSIDE CIRCUIT BREAKERS SHALL HAVE A MANUFACTURER'S LABEL STATING THE LISTING FOR THE SERIES COMBINATION INTERRUPTING RATING FOR THE LOADSIDE CIRCUIT BREAKERS AND THE LINESIDE FUSE (OR CIRCUIT BREAKER) COMBINATION, IN COMPLIANCE WITH NEC SECTION 240-86. THIS SERIES RATING SHALL BE EQUAL TO OR GREATER THAN THE AVAILABLE SHORT-CIRCUIT CURRENT. WHERE SERIES RATED COMBINATIONS ARE UTILIZED, THE ELECTRICAL CONTRACTOR SHALL AFFIX FIELD INSTALLED LABELS TO THE LOADSIDE CIRCUIT BREAKER PANELBOARD AND FEEDER SWITCH/PANELBOARD/SWITCHBOARD, IN COMPLIANCE WITH NEC SECTION 110-22. AS REQUIRED IN SECTION 110-22, THE LOADSIDE PANELBOARD/SWITCHBOARD LABEL SHALL BE FIELD MARKED WITH THE SHORT-CIRCUIT RATING OF THE SERIES COMBINATION, TYPE CIRCUIT BREAKER FOR REPLACEMENT, PART NUMBER FOR THE SERIES RATED LINESIDE, FEEDER FUSES AND LOCATION/NAME OF THIS FUSE SWITCH/PANELBOARD/SWITCHBOARD. THE PANEL/SWITCH WITH THE LINESIDE FUSES (OR CIRCUIT BREAKER) SHALL BE FIELD MARKED WITH SHORT-CIRCUIT RATING OF THE SERIES COMBINATION, PART NUMBER FOR FUSE (OR CIRCUIT BREAKER) REPLACEMENT AND THE LOCATION/NAME OF LOADSIDE, SERIES RATED PANELBOARD/SWITCHBOARD. IF THE MANUFACTURER/SUPPLIER/INSTALLER CANNOT SUPPLY TESTED AND LISTED SERIES RATED COMBINATIONS OF THE SPECIFIED LOADSIDE CIRCUIT BREAKERS WITH THE SPECIFIED LINE SIDE FUSES, IT IS THEIR RESPONSIBILITY TO PROVIDE LOADSIDE CIRCUIT BREAKERS THAT HAVE FULLY RATED INTERRUPTING RATINGS EQUAL TO OR GREATER THAN THE SHORT-CIRCUIT CURRENT AVAILABLE AT THE LOADSIDE CIRCUIT BREAKERS. SERIES RATING : METER STACKS WITH SERIES RATED LOADSIDE CIRCUIT BREAKERS SHALL HAVE A MANUFACTURER'S LABEL STATING THE LISTING FOR THE SERIES COMBINATION INTERRUPTING RATING FOR THE LOADSIDE CIRCUIT BREAKER, IN COMPLIANCE WITH NEC SECTION 240-86. THIS SERIES RATING SHALL BE EQUAL TO OR GREATER THAN THE AVAILABLE SHORT-CIRCUIT CURRENT. WHERE SERIES RATED COMBINATIONS ARE UTILIZED, THE ELECTRICAL CONTRACTOR SHALL AFFIX FIELD INSTALLED LABELS TO THE LOADSIDE CIRCUIT BREAKER PANELBOARD AND AND METER STACK LOAD CENTERS, IN COMPLIANCE WITH NEC SECTION 110-22. IF THE MANUFACTURER/SUPPLIER/INSTALLER CANNOT SUPPLY TESTED AND LISTED SERIES RATED COMBINATIONS OF THE SPECIFIED LOADSIDE CIRCUIT BREAKERS, IT IS THEIR RESPONSIBILITY TO PROVIDE LOADSIDE CIRCUIT BREAKERS THAT HAVE FULLY RATED INTERRUPTING RATINGS EQUAL TO OR GREATER THAN THE SHORT-CIRCUIT CURRENT AVAILABLE AT THE LOADSIDE CIRCUIT BREAKERS. 1. 2. 3. RESIDENTIAL COMMERCIAL HOUSE PANEL (EST) TOTAL AT 90% PF AT 208V 3 PH SERVICE RECAP = = = = = = 78.72 48.65 25.00 152.37 169.30 470 kW kW kW kW kVA AMPS Space Retail 1 Retail 2 Retail 3 Office TOTAL AT 208V 3 PH COMMERCIAL LOAD SUMMARY Sq Ft 1175 1185 719 975 W/sf 12 12 12 12 Total 14100 14220 8628 11700 48648 135 W W W W W AMPS Unit 1Bed+Den Studio UpBed 1 UpBed 2 Appliance Load Two Appliance Circuits Laundry Circuit Range Dishwasher Disposal Dryer Furnace Gas Water Heater Air Conditioning Units Total Note: Per NEC 220 - 84 for 6 units a demand factor of 0.44 was used. Sq Ft 496 426 751 698 Demand Factor At 240V 1PH W/SF 3 3 3 3 44% RESIDENTIAL BUILDING CALCULATIONS Watts/Unit 1488 1278 2253 2094 Watts/Unit 3000 1500 12000 1200 1176 5000 1128 240 2928 Qty 2 2 1 1 Qty 6 6 6 6 6 6 6 6 6 Total 2976 2556 2253 2094 Total 18000 9000 72000 7200 7056 30000 6768 1440 17568 178911 78721 328 W W W W W W W W W W W W W W W Amps FEEDER SCHEDULE 2 RUNS [(4 #350 KCMIL THWN CU) 4"C.] & (1) SPARE 4"C. (#6 CU GRD) 3/4"C. (#2/0 CU GRD) 3/4"C. (#4 CU GRD) 3/4"C. (4 #1 THWN CU & #8 CU GRD) 2"C. (4 #3/0 THWN CU & #6 CU GRD) 2 1/2"C. (4 #3/0 THWN CU & # #6 CU GRD) 2 1/2"C. (4 #1 THWN CU & #8 CU GRD) 2"C. (4 #1 THWN CU & #8 CU GRD) 2"C. (3 #1 THWN CU & #8 CU GRD) 1 1/2"C. 1 2 3 4 5 6 7 8 9 10 DARK BRONZE TYPE 'BB' 6801 W. 20th Street, Suite #212 GREELEY, COLORADO 80634 GREELEY: (970) 330-3266 FACSIMILE: 1 (888) 551-1062 & ASSOCIATES, LLC ELECTRICAL ENGINEERS - PLOT DATE A A 1 2 3 4 5 5 4 3 2 1 B C D A B C D issue date: project #: T - 970.430.5220 405 linden street fort collins, co, 80524 © 2015 www.auworkshop.co 5/24/2016 12:04:52 PM E‐400 1504 ELECTRICAL ONE-LINE Poudre Garage 148 Remington St Fort Collins, Co 80524 Poudre Garage, LLC Development Review 05/25/2016 5 4 3 2 1 B C D A B C D issue date: project #: T - 970.430.5220 405 linden street fort collins, co, 80524 © 2015 www.auworkshop.co 5/24/2016 12:04:51 PM E‐101 1504 ELECTRICAL SITE PLAN - NEW Poudre Garage 148 Remington St Fort Collins, Co 80524 Poudre Garage, LLC Development Review 05/25/2016 Electrical Site Plan - Demo DRAWING INDEX Sheet Number Sheet Name E-100 ELECTRICAL SITE PLAN - DEMO E-101 ELECTRICAL SITE PLAN - NEW E-400 ELECTRICAL ONE-LINE 6801 W. 20th Street, Suite #212 GREELEY, COLORADO 80634 GREELEY: (970) 330-3266 FACSIMILE: 1 (888) 551-1062 & ASSOCIATES, LLC ELECTRICAL ENGINEERS - PLOT DATE A A 1 2 3 4 5 5 4 3 2 1 B C D A B C D issue date: project #: T - 970.430.5220 405 linden street fort collins, co, 80524 © 2015 www.auworkshop.co 5/24/2016 12:04:49 PM E‐100 1504 ELECTRICAL SITE PLAN - DEMO Poudre Garage 148 Remington St Fort Collins, Co 80524 Poudre Garage, LLC Development Review 05/25/2016