Loading...
HomeMy WebLinkAboutPROSPECT 7-ELEVEN STORE NO. 35506 - PDP - PDP120002 - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCEREPORT OF GEOTECHNICAL ENGINEERING EVALUATION PROPOSED 7-ELEVEN 3045 WEST PROSPECT ROAD FORT COLLINS, COLORADO PSI PROJECT NUMBER 0532395 Prepared for Ripsaw Development, LLC c/o Verdad Real Estate 1121 Grant Street Suite 2-A Denver, Colorado Attn: Ms. Jen Volin Prepared by Professional Service Industries, Inc. ELECTRONIC COPY 1070 West 124th Avenue, Suite 800 Westminster, Colorado 80241 Matthew R. Satterfield, P.E. (303) 424-5578 Project Engineer ELECTRONIC COPY Chris P. Willden, E.I. Staff Engineer Reviewed By: Kevin C. Miller, P.E. December 9, 2011 Principal Consultant TABLE OF CONTENTS 1.0 INTRODUCTION.........................................................................................................1 2.0 PROJECT INFORMATION.........................................................................................1 3.0 SUBSURFACE INFORMATION.................................................................................2 3.1 SITE GEOLOGY AND GEOLOGIC HAZARDS...................................................................2 3.2 SUBSURFACE CONDITIONS.........................................................................................2 3.2.1 Subsurface Profile .............................................................................................2 3.2.2 Groundwater Conditions....................................................................................3 3.2.3 Laboratory Testing.............................................................................................3 4.0 GEOTECHNICAL EVALUATION...............................................................................4 5.0 SITE GRADING RECOMMENDATIONS....................................................................4 5.1 ENGINEERED FILL ......................................................................................................4 5.1.1 Imported Structural Fill ......................................................................................5 5.2 GENERAL FILL PLACEMENT AND TESTING ...................................................................5 5.3 BACKFILL OF EXISTING UNDERGROUND STORAGE TANKS ...........................................6 6.0 GEOTECHNICAL RECOMMENDATIONS.................................................................6 6.1 FOUNDATIONS ...........................................................................................................6 6.2 SLABS ON GRADE ......................................................................................................8 6.4 SEISMIC PARAMETERS .............................................................................................10 6.5 PAVEMENT DESIGN RECOMMENDATIONS ..................................................................10 6.5.1 Subgrade Preparation Recommendations ......................................................10 6.5.2 Pavement Thickness Recommendations ........................................................11 6.5.3 Flexible Pavement ...........................................................................................12 6.4.4 Aggregate Base Course ..................................................................................12 6.5.5 Rigid Pavement ...............................................................................................12 7.0 LIMITATIONS ...........................................................................................................13 ATTACHMENTS Site Location Map (Figure 1) Boring Location Map (Figure 2) Boring Logs (Figures 3 through 6) Key to Symbols (Figure 7) Appendix A – Laboratory Test Results Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 1 of 13 1.0 INTRODUCTION Professional Service Industries, Inc. (PSI) has conducted a geotechnical engineering exploration of the site for the proposed 7-Eleven to be located at 3045 West Prospect Road in Fort Collins, Colorado. The purpose of our study was to characterize the subsurface strata at the subject site and to develop recommendations for site preparation and foundation design for the proposed 7-Eleven structure. Our services on this project were in accordance with the PSI Proposal No. 57484, which was authorized by TK Keen with Ripsaw Development on November 15, 2011. PSI’s scope of services for the geotechnical study did not include an assessment of environmental conditions in the soil, bedrock, surface water, groundwater, or air, on or below, or around this site. Any statements in this report or on the boring logs regarding odors, colors, and unusual or suspicious items or conditions are strictly for informational purposes. The report, which follows, presents a brief review of our understanding of the project, a discussion of the site and subsurface conditions, and our recommendations. 2.0 PROJECT INFORMATION PSI understands that Ripshaw Development is planning the construction of a new 7- Eleven convenience store to be located at the southeast corner of West Prospect Road and South Overland Trail in Fort Collins, Colorado (See Figures 1 and 2). PSI’s project understanding is based on information provided by Ms. Volin via email on November 14, 2011, along with information provided for our Environmental Phase I proposal. This information included a “Concept Layout – Alt 0” dated November 10, 2011, and a site survey dated October 25, 2011 The site currently has a gas station occupying the the lot. The existing gas station has underground storage tanks for their fueling services. PSI has included recommendations in this report for backfilling excavations if the tanks are removed. The latitude and longitude of the subject site is approximately 40º 34’ 04” North and 105º 08’ West. The site is bounded by South Overland Trail to west, West Prospect Road to the north, and commercial developments to the south and east. The site is relatively flat with grade changes on the order of approximately two feet. Based on the information provided to PSI, we understand that the proposed 7-Eleven development will include the construction of a 3,008 square foot, single story-building. A slab-on-grade floor system is preferred for the 7-Eleven Structure. Foundation loads were not provided to PSI at the time of this study. However, this report is based on the project loads having typical ranges as follows: column loads from 75 to 120 kips and wall loads of 1 to 1.5 kips per linear foot. Grading plans were provided to PSI, we expect cuts and fills on the site will be on the magnitude two feet. Descriptions of the site are based upon observations made during our field exploration program. The geotechnical recommendations presented in this report are based upon the available project information and the subsurface materials described in this report. If any of the noted information is incorrect, please inform us so that we may amend the recommendations presented in this report, if needed. Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 2 of 13 3.0 SUBSURFACE INFORMATION The following sections provide information relating to subsurface conditions in the area of the proposed addition. The geology section is based upon the “Geologic Map of Colorado” by Ogden Tweto, dated 1979 and information relating to subsurface conditions within the property gathered from our current field study. 3.1 Site Geology and Geologic Hazards The site is located on the high plains approximately 1 mile east of the foothills of the Rocky Mountains. Based on the United States Geological Survey (USGS) “Geologic Map of Colorado” by Ogden Tweto, 1979, the majority of the site is mapped as being underlain by Colorado Group (Kc) deposits which includes either Benton shale or Carlile, Greenhorn, and Graneros formations. 3.2 Subsurface Conditions As part of PSI’s evaluation of this site, 4 exploratory borings were drilled at the subject site as indicated on Figure 2, the Boring Location Map. Borings B1 and B2 were drilled within the footprint of the proposed 7-Eleven and extended to depths of approximately 20 feet below the existing grade. Borings B3 and B4 were drilled within the proposed new pavement area and extended to depths of approximately 5 feet below grade. The borings were advanced using a CME-55 truck mounted drill rig equipped with 4-inch diameter, solid-stem, continuous-flight auger. Soil samples were recovered at selected depths during drilling with the truck-mounted drill rig using a Modified California Barrel Sampler (inside diameter- 2.0 inches and outside diameter- 2.4 inches) or a Standard Split Spoon Sampler (inside diameter- 1.375 inches and outside diameter- 2 inches) driven by a 140-lb. weight free falling 30 inches. The number of blows required to drive the sampler 12 inches is designated as the penetration resistance (N-value, blows per foot) and provides an indication of the consistency of cohesive soils and the relative density of granular materials. While the procedure is similar to that employed in the Standard Penetration Test (ASTM D1586), the penetration resistance obtained using the California barrel sampler is generally higher than that obtained using the standard split spoon sampler. A PSI engineer from our office observed the drilling and prepared borings and logs of the conditions encountered. Individual logs of the borings are presented on Figures 3 through 6. It should be noted that the subsurface conditions presented on the boring logs are representative of the conditions at the specific locations drilled. Variations may occur and should be expected across the site. The stratification represents the approximate boundary between subsurface materials and the transitions may be gradual and indistinct. Water level information, if encountered, obtained during our field operations is also shown on the boring logs. 3.2.1 Subsurface Profile In general, PSI encountered fill material to approximately 2 feet below grade. Beneath the fill material, native overburden soils were encountered to the termination of the borings, approximately 20 feet below grade. PSI encountered approximately 3 inches of asphalt pavement in the borings. The fill material was generally dark gray to dark brown, gravelly in parts and fine to coarse grained sand. Underlying the fill material, the native overburden material generally consisted of clayey sand and sandy clay. In general the Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 3 of 13 native overburden material was reddish brown, fine to medium grained sand, moist and soft to stiff. Sedimentary bedrock was not encountered during our field activities. The table below provides general engineering properties for the native overburden materials encountered. Material / Property Dry Density (pcf) Moisture Content (%) Liquid Limit (%) Plastic Limit (%) N Value (blows/ft) Swell (%) CLAYEY SAND/ Range 110-128 8-19 24-30 13-16 10-30 0.3-1.2 SANDY CLAY (SC-CL) Average 116 11 28 15 17 0.6 * Swell percentage when wetted under a 250 psf surcharge pressure As can be seen above, PSI performed Denver Swell Testing on selected samples of the overburden material collected during our field investigation. The test results indicated swell percentages ranging from 0.3% in building area to 1.2% in the pavement area, when tested under a 250 psf surcharge pressure. PSI classifies the soil conditions encountered in our investigation as having low swell potential. PSI does not recommend swell mitigation be performed for the proposed construction. The Boring Logs illustrated in Figures 3 through 6 should be reviewed for specific information at individual boring locations. These records include soil descriptions, stratifications, penetration resistances, locations of the samples and laboratory test data. 3.2.2 Groundwater Conditions Groundwater was not encountered during our drilling operations. However, the in-situ moisture contents of samples collected in the field indicate that the native soils may be saturated. PSI believes that the actual groundwater elevation may be as high as 5 feet below grade. It should be noted that it is possible for the groundwater table to fluctuate during the year depending upon climatic and rainfall conditions and changes to surface topography and drainage patterns. Discontinuous zones of perched water may also exist, or develop, within the overburden materials subsequent to the construction. The groundwater levels presented in this report are the levels that were measured at the time of our field activities. 3.2.3 Laboratory Testing The soil samples obtained during the field exploration were transported to the laboratory and selected soil samples were tested in the laboratory to determine material properties for our evaluation. Laboratory testing was accomplished in general accordance with ASTM and other applicable procedures. Laboratory testing was performed on selected samples to evaluate the classification, swell and other engineering characteristics of the subsurface materials. Laboratory test data along with detailed descriptions of the soils can be found on the logs of borings and in Appendix A. The samples that were not Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 4 of 13 altered by laboratory testing will be retained for 30 days from the date of this report and then will be discarded without further notice. 4.0 GEOTECHNICAL EVALUATION The following geotechnical related recommendations have been developed on the basis of the subsurface conditions encountered and PSI’s understanding of the proposed development. Should changes in the project criteria occur, a review must be made by PSI to determine if modifications to our recommendations will be required. There are 2 primary geotechnical concerns at the site, which will affect the performance of the foundations for this structure. The following summarizes those concerns. 1. The shear strength and compressibility of the upper soils will control the behavior of the proposed structure. 2. Existing undocumented fill material was encountered within the proposed development area. 1. Shear Strength and Compressibility of Soil Due to the sandy nature of the soils found during our investigation, the calculated settlements will control the foundation size of the structures. Even though the clayey sand material yields a relatively high allowable bearing capacity, limiting the loads applied to the strata can limit the potential settlement of the structures. PSI provides allowable bearing capacities along with the calculated settlements that could be anticipated. 2. Existing Undocumented Fill Based on PSI’s field investigation, the site is underlain by 1 ½ to 2 feet of fill material. Due to the consistency of the fill material encountered, PSI does not recommend that the fill material be overexcavated and replaced. However, if loose material is encountered during excavations, PSI recommends that the loose soils be overexcavated and replaced as structural fill material. 5.0 SITE GRADING RECOMMENDATIONS Prior to excavation for foundation construction, the site should be stripped of asphalt pavement, vegetation, topsoil, loose uncompacted fill, soil stockpiles, and debris. The stripped vegetation/topsoil may be re-placed as topsoil in designated landscape areas. The loose soils or stockpiled soils may be incorporated and placed as structural fill. Trash and debris should be disposed of in accordance with local and state regulations. 5.1 Engineered Fill Based on PSI’s field and laboratory data it is our opinion that on-site overburden soils will be suitable for re-use as backfill soils and for use as structural fill, provided the material is properly moisture conditioned and compacted. If unanticipated material such as construction debris, trash, or other undesirable material is encountered during construction, they should be removed off site. Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 5 of 13 5.1.1 Imported Structural Fill Imported structural fill, if required, should be free of organic or other deleterious materials, have a liquid limit less than 30, a plasticity index less than 10, and meet the following gradation outlined below. This structural fill criteria is intended as a general guideline. Imported structural fill materials should have a swell potential of less than 1 percent when compacted to 95 percent of maximum dry unit weight (MDUW) and at 2 percent below optimum moisture content (OMC) and tested under a swell test surcharge of 500 psf. The MDUW and OMC should be determined by ASTM D698 (Standard Proctor). Screen Size Percent Passing 2 Inch 100 #4 50 – 100 #200 < 30 Imported fill material proposed for use on this site that does not meet these criteria should be submitted to the project geotechnical engineer for evaluation and approval. The geotechnical engineer should evaluate the proposed import fill prior to purchase and delivery. Fine-grained soils used for fill require close moisture content control and careful placement by the contractor to achieve the recommended degree of compaction and to control swell potential and settlement. 5.2 General Fill Placement and Testing Unless otherwise specified, fill material should be compacted to at least 95 percent of the maximum dry unit weight as determined by the Standard Proctor Test (ASTM D 698). Each lift of compacted fill should be tested for density by a representative of the geotechnical engineer prior to placement of subsequent lifts. Sand fill soils should be moisture conditioned to between two percent below and two percent above optimum moisture content and clay fill soils should be moisture conditioned to a range from optimum moisture content to four percent above optimum moisture content. Fill material should be placed in maximum eight inch loose lifts. A sample(s) of the proposed backfill soil(s) should be obtained for moisture density relationship (proctor test) three to four days prior to backfilling operations to expedite compaction and moisture content testing by the materials testing service provider. Weather conditions in the site area are typically dry in the summer and early fall. Precipitation in the form of snowfall is common from October through March. While grading can be inhibited for short periods during and following times of precipitation, grading can generally be conducted year round. The major factor that must be considered during the winter months is ground freezing. During extended periods of Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 6 of 13 sub-freezing weather, it can be difficult to properly moisture condition and compact soils. Grading must be conducted during the warmer parts of the day in freezing weather. 5.3 Backfill of Existing Underground Storage Tanks If the existing underground storage tanks at the site are removed, PSI recommends backfilling the excavations with CDOT Class 2 material to approximately 3 feet below the final grade. The CDOT Class 2 material should be placed in loose 8’’ lifts and each lift should be compacted in accordance with section 5.2 of this report. When the CDOT Class 2 material is within 3 feet below final grade, a geo-fabric should be placed over the material and structural fill should be used to backfill the top 3 feet of the excavations. The structural fill should meet the criteria mentioned in this report and be placed and compacted in accordance with section 5.2 of this report. 6.0 GEOTECHNICAL RECOMMENDATIONS The proposed structure may be founded on continuous or individual column footings bearing in competent native clayey sand and sandy clay materials and may also employ slab-on-grade floors, provided the site is prepared as previously outlined. The geotechnical engineer should verify that the soils encountered in our investigation are consistent with the conditions encountered during foundations excavations. 6.1 Foundations PSI recommends that the proposed structure be supported on continuous or individual column footings and should be designed for an allowable soil bearing pressure as shown in the following tables: Allowable Bearing Column Pad Size (inches) Capacity of Individual Column Pad 48 X 48 60 X 60 66 X 66 72 X 72 1 ½ feet N/A N/A N/A 3,700 psf 3 feet N/A 4,950 psf 5,125 psf 5,275 psf 4 feet N/A 6,100 psf 6,250 psf 6,400 psf Bearing Depth of Foundation below existing grade 5 feet N/A 7,325 psf 7,450 psf 7,575 psf N/A= Allowable bearing capacities do not meet the required bearing loads based on the 120 kips column load used in the calculations. Allowable Bearing Capacity of Continuous Footing Allowable Bearing Capacity 1 ½ feet 1,650 psf 3 feet 3,350 psf Bearing Depth of Foundation Below Existing Grade 4 feet 4,675 psf Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 7 of 13 The allowable bearing capacities provided in the tables above are based on a factor of safety of 3 and that the existing grade is at or near the proposed final grade elevation. The above bearing capacities were calculated using 120 kip column loads and a 1.5 kips per linear foot continuous footing loads. PSI has calculated the expected settlement using 120 kip column loads and 1.5 kips per linear foot continuous footing loads. The expected settlement results are displayed in the following tables. Column Pad Size (inches) Expected Settlement 48 X 48 60 X 60 66 X 66 72 X 72 1 ½ feet N/A N/A N/A 1-1/8 in. 3 feet N/A 1-3/8 in. 1-1/4 in. 1 in. 4 feet N/A 1-3/8 in. 1-1/8 in. 1 in. Bearing Depth of Foundation below existing grade 5 feet N/A 1-1/4 in. 1-1/8 in. 1 in. N/A= Not calculated because the bearing capacities do not meet the required bearing loads based on the 120 kip column load used in the calculations. Expected Settlement (inches) Continuous Footing – 16 Inches Wide 1 ½ feet ¼ inch 3 feet ¼ inch Bearing Depth of Foundation below existing grade 4 feet ¼ inch Continuous footings supporting bearing walls should incorporate a minimum lateral dimension of 16 inches. Exterior footings should bear at a minimum of 36 inches below final grade for frost protection. Interior footings should bear at 18 inches below final grade. However, if the footing excavations expose the onsite fill material at the elevation of the bottom of the footing, PSI recommends extending the bottom of the footing depths to native soil. The uplift capacity of shallow foundations should be limited to the weight of the foundation concrete plus the weight of the soil immediately above the footing. A concrete unit weight of 145 pcf and a soil unit weight of 110 pcf should be used for design purposes. Lateral loads applied to the foundations will be resisted by a combination of passive pressure against the sides and friction along the base. For design purposes, PSI Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 8 of 13 recommends using an equivalent fluid pressure of 50 pcf for the “active” case and 70 pcf for the “at-rest” case. A passive pressure of 250 pcf to a depth of 15 feet along with a coefficient of friction of 0.3 is recommended. The foundation excavations should be observed by a representative of PSI prior to reinforcing steel or concrete placement to assess that the foundation bearing materials are capable of supporting the design loads and are consistent with the materials discussed in this report. Soft or loose zones encountered at the bottom of the footing should be removed and replaced with properly compacted fill as directed by the geotechnical engineer. After the foundation bearing materials have been approved, steel reinforcement and concrete should be placed as quickly as possible to avoid exposure of the footing bottoms to wetting and drying. Surface run-off water should be drained away from the excavations and not be allowed to pond. If possible, the foundation concrete should be placed during the same day the excavation is made. If it is required that the excavation be left open for more than one day, they should be protected to reduce evaporation or entry of moisture. 6.2 Slabs on Grade A slab-on-grade interior floor slab system may be utilized for the proposed addition. PSI anticipates that slabs-on-grade placed on soil prepared as stated in this could experience total movement on the order of 1 inch with differential movements on the order of ½ inch over a 50 foot span. This settlement is based on the slabs not exceeding 150 psf loading. PSI recommends proofrolling the subgrade for the slabs to identify areas of loose soils prior to placement of concrete. The proofroll should be conducted with a loaded tandem-axle dump truck or similar pneumatic-tired equipment with a minimum weight of 15 tons and a maximum weight of 25 tons. If soft spots are discovered in the subgrade, they should be overexcavated and replaced with reconditioned and compacted structural fill in accordance with this report. If the slab is placed on structural fill material PSI recommends a subgrade support modulus (k-value) of 125-pci (based on a 1 foot square plate load test) be used for slab design. However, depending on how the slab load is applied, the value will have to be geometrically modified. The value should be adjusted for larger areas using the following expression for cohesive and cohesionless soil: Modulus of Subgrade Reaction, ks = ( B k ) for cohesive soil and ks = k ( B B 2  1 )2 for cohesionless soil where: ks = coefficient of vertical subgrade reaction for loaded area, k = coefficient of vertical subgrade reaction for 1x1 square foot area, and B = width of area loaded, in feet Where concrete slabs will be covered with tile or other moisture sensitive covering, we recommend the use of a vapor retarder beneath the slabs on grade to reduce vapor transmission through the slab. Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 9 of 13 The precautions listed below are considered good construction practice. Due to the non- expansive soils encountered on-site, these recommendations are not required, but can be followed to prevent moisture content variation.  Cracking of slabs-on-grade can occur as a result of heaving or compression of the supporting soil, but also as a result of concrete curing stresses. The occurrence of concrete shrinkage cracks, and problems associated with concrete curing may be reduced and/or controlled by limiting the slump of the concrete, proper concrete placement, finishing, and curing, and by the placement of crack control joints at frequent intervals, particularly, where re-entrant slab corners occur. The American Concrete Institute (ACI) recommends a maximum panel size (in feet) equal to approximately three times the thickness of the slab (in inches) in both directions. For example, joints are recommended at a maximum spacing of 12 feet assuming a four- inch thick slab. We also recommend that control joints be scored three feet in from and parallel to all foundation walls. Using fiber reinforcement in the concrete can also control shrinkage cracking.  A minimum 1-inch void space is recommended above, or below partitions that are placed on the slab. In finished areas, all furring strips, drywall and paneling should stop at least 1 inch from the top of the slab. The void space can be covered with a molding strip. Doorways should also be designed for this movement. NOTE: These void spaces are not intended to anticipate total potential slab movement. They are intended to prevent immediate damage to the superstructure and serve as an indicator of slab movement. They must be monitored and maintained by the owner for the life of the structure.  Slabs should be separated from exterior walls, column posts, interior bearing members and utility lines to allow independent vertical movement of the slab. If project structural and architectural details require the slab on grade to be structurally tied to the exterior wall/foundation system, then control joints should be placed in the slab within approximately 3 feet of the wall. The owner must understand and accept the risk of cracking at or near the control joints if the slab on grade is tied to the foundation system.  Some increase in moisture content is inevitable as a result of development and associated landscaping. However, extreme moisture content increases can be largely controlled by proper and responsible site drainage, building maintenance and irrigation practices.  Utility backfill in areas supporting slabs should be moisture conditioned or dried by scarification, and compacted. Backfill in all interior and exterior water and sewer line trenches should be uniformly compacted. Exterior slabs should be isolated from the building. These slabs should be reinforced to function as independent units. Movement of these slabs should not be transmitted to the building foundation or superstructure. Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 10 of 13 6.4 Seismic Parameters The project site is located within a municipality that employs the International Building Code, 2006 edition. As part of this code, the design of structures must consider dynamic forces resulting from seismic events. These forces are dependent upon the magnitude of the earthquake event as well as the properties of the soils that underlie the site. As part of the procedure to evaluate seismic forces, the code requires the evaluation of the Seismic Site Class, which categorizes the site based upon the characteristics of the subsurface profile within the upper 100 feet of the ground surface. To define the Site Class for this project, we have interpreted the expected results of soil test borings drilled with the project site and estimated appropriate soil properties below grade to a depth of 100 feet, as permitted by Section 1615.1.1 of the code. The estimated soil properties were based upon data available in published geologic reports as well as our experience with subsurface conditions in the general site area. Based upon our evaluation, it is our opinion that the subsurface conditions within the site are consistent with the characteristics of Site Class D as defined in Table 1615.1.1 of the building code. The USGS-NEHRP interpolated probabilistic ground motion values near 40º 34’ 04” North and 105º 08’ West obtained from the USGS geohazards web page are as follows: Period 2% Probability of Event in 50 years Site Coefficient Site Coefficient (seconds) (% g) Fa Fv 0.2 (Ss) 18.9 1.6 NA 1.0 (S1) 5.9 NA 2.4 The Site Coefficients, Fa and Fv presented in the above table were interpolated from IBC Tables 1615.1.2(1) and 1615.1.2(2) as a function of the site classification and mapped spectral response acceleration at the short (Ss) and 1 second (S1) periods. 6.5 Pavement Design Recommendations The following analysis and pavement thickness recommendations are in general accordance with AASHTO and the Colorado Department of Transportation Pavement Design Manual. 6.5.1 Subgrade Preparation Recommendations Due the fill material encountered during PSI’s field investigation, PSI recommends that the subsurface material be overexcavated to a depth of 1 foot below final subgrade elevation and replaced as moisture conditioned and compacted structural fill. This will provide a more uniform subgrade for support of the proposed pavement sections. Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 11 of 13 PSI recommends that the subgrade soils to support the proposed pavements be overexcavated to a depth of 1 feet below final subgrade elevation and replaced as moisture conditioned compacted structural fill in accordance with Section 5.1. Once the areas below the parking area have been overexcavated, the existing site soils should be proofrolled to identify areas of loose soils prior to placement of moisture conditioned, compacted soils (either on-site or imported). The proofroll should be conducted with a loaded tandem-axle dump truck or similar pneumatic-tired equipment with a minimum weight of 15 tons and a maximum weight of 25 tons. 6.5.2 Pavement Thickness Recommendations Based on the sandy clay material encountered during our subsurface investigation, PSI has based this report on an R-value of 7 to support the proposed pavement sections. PSI has identified two pavement categories based on anticipated traffic use and traffic loads. We have assigned estimated traffic loads to each category expressed in EDLA’s, where the EDLA is the equivalent daily load applications of vehicles relative to an 18-kip single axle load. We have also based the pavement thickness design on the following design criteria; a 20-yr design life, a Pavement Serviceability Index (PSI) of 2.0 and a Reliability of 85%.  PSI has assigned an estimated EDLA of 2 for the general parking stall (Light Duty Traffic) area. Anticipated traffic in this area includes private passenger vehicles or similar vehicles.  The drive lanes within the site have been assigned an estimated EDLA of 5 (Heavy Duty Traffic - Drive Lanes), PSI anticipates that traffic in this area will be mixed use consist of delivery vehicles of varying size and weight and passenger vehicles. Pavement section options are provided for full depth asphalt, asphalt over aggregate base course, and rigid (Portland Cement Concrete) pavement. However, it is PSI’s experience that pavements with properly placed base aggregate on a properly drained grade outperforms full depth pavement sections. Based on this information for the subject pavement, the following pavement sections were determined, as presented below. Pavement Area Composite Section (inches) Full-Depth Asphalt (inches) Full-Depth Portland Cement Concrete (inches) Light Duty Traffic Parking Stalls (EDLA = 2) 3 ½ inches Asphalt over 7 inches Aggregate Base Course 6 inches 6 inches Heavy Duty Traffic Drive Lanes (EDLA = 5) 4 inches Asphalt over 8 inches Aggregate Base Course 6 ½ inches 6 inches Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 12 of 13 Concrete pavement at least seven inches thick is recommended for the trash dumpster run-up due to the heavy wheel and impact loads that this area receives. The run-up should extend far enough away to support all wheels of the sanitation truck while stopped and in the loading position. Concrete pavement is also recommended in areas, which receive continuous repetitive traffic such as product unloading areas and parking lot entrances. 6.5.3 Flexible Pavement Structural sections for parking lot and drive lane pavements may be full depth asphalt, a composite section of asphalt pavement over aggregate base course or Portland Cement concrete pavement. Flexible pavement is not recommended for Dumpster Pad/ Sanitation Truck Run-up areas. For Dumpster Pad/Sanitation Truck Run-up areas we recommend rigid pavement as discussed in the following Rigid Pavement Section. Allowances for proper drainage and proper material selection of base materials are most important for performance of asphaltic pavements. Ruts and birdbaths in asphalt pavement allow for quick deterioration of the pavement primarily due to saturation of the underlying base and subgrade. Hot bituminous pavement should meet the requirements as detailed for SuperPave Mixtures in Colorado Department of Transportation Standard Specifications for Road and Bridge Construction. Material meeting the Colorado Department of Transportation requirements for Grading S (¾ inch nominal) or Grading SG (1 ½ inch nominal) is recommended. In addition, the following are presented as general guidelines for properties of asphaltic concrete. Parking Lot Asphalt Cement PG 64-22 Asphalt Content As per mix design Percent Air Voids 3½-5 Asphalt material should be obtained from an approved mix design stating the SuperPave Mixture properties, including optimum asphalt content, job mix formula, and recommended mixing and placing temperatures. Materials and construction methods should be in accordance with the CDOT Standard Specifications for Road and Bridge Construction Section 403. 6.4.4 Aggregate Base Course If aggregate base course is used as part of the pavement section, the materials should conform to CDOT requirements for Class 5 or 6 aggregate base course per Table 703-2 and construction methods should conform to Section 304 of the Colorado Department of Transportation Standard Specifications for Road and Bridge Construction. 6.5.5 Rigid Pavement The use of concrete for on-site pavements may be considered by the owner. Should concrete pavement be utilized, the concrete should be properly reinforced and jointed Proposed 7-Eleven December 9, 2011 3045 West Prospect Road PSI Project No. 0532395 Fort Collins, Colorado Page 13 of 13 and should be constructed from a concrete mixture, which has a 28-day minimum laboratory compressive strength of 4,000 psi. We recommend a maximum water cement ratio of 0.45 and an air-entrainment specification of 5 percent (±1.5 percent) be followed. Expansion joints should be sealed with a polyurethane sealant so that moisture infiltration into the subgrade soils and resultant concrete deterioration at the joints is reduced. 7.0 LIMITATIONS The recommendations submitted are based on the available subsurface information obtained by PSI and design details furnished by Ripsaw Development and 7-Eleven. If there are revisions to the plans for this project or if deviations from the subsurface conditions noted in this report are encountered during construction, PSI should be notified immediately to determine if changes in the foundation recommendations are required. If PSI is not retained to perform these functions, PSI will not be responsible for the impact of those conditions on the project. The geotechnical engineer warrants that the findings, recommendations, specifications, or professional advice contained herein have been made in accordance with generally accepted professional geotechnical engineering practices in the local area. No other warranties are implied or expressed. After the plans and specifications are more complete, the geotechnical engineer should be retained and provided the opportunity to review the final design plans and specifications to check that our engineering recommendations have been properly incorporated into the design documents. At that time, it may be necessary to submit supplementary recommendations. This report has been prepared for the exclusive use of 7-Eleven and their consultants for the specific application to the proposed 7-Eleven Store located at 3045 West Prospect Road in Fort Collins, Colorado. SC CL SC 15 9 7 18 10 1 2 3 4 5 12 12 12 12 12 DD = 110 pcf -200 = 44.8% DD = 113 pcf LL = 24 PL = 13 DD = 117 pcf -200 = 19.4% DD = 112 pcf LL = 30 PL = 14 DD = 128 pcf -200 = 24.1% 7-6 N=13 3-9 N=12 9-12 N=21 10-10 N=20 12-18 N=30 ASPHALT - Approximately 3 Inches Thick MAN-MADE FILL- Composed of Sand and Clay, Fine to Coarse Grained Sand, Gravel in Areas, Dark Gray to Dark Brown CLAYEY SAND (SC) - Reddish Brown, Fine to Medium Grained Sand, Moist, Medium Stiff to Stiff SANDY CLAY (CL) - Silty in Parts, Reddish Brown, Fine to Medium Grained Sand, Moist, Stiff CLAYEY SAND (SC) - Tan, Fine to Coarse Grained Sand, Moist, Very Stiff PROJECT NO.: 0532395 PROJECT: 7-Eleven Depth, (feet) STRENGTH, tsf Additional Remarks USCS Classification 0 SC CL SC 8 18 19 1 2 3 4 5 12 12 12 12 12 S(250) = 0.3% -200 = 31.5% DD = 122 pcf -200 = 28.7% DD = 111 pcf -200 = 79.2% DD = 110 pcf LL = 31 PL = 14 10-12 N=22 6-6 N=12 7-9 N=16 7-10 N=17 6-10 N=16 ASPHALT - Approximately 3 Inches Thick MAN-MADE FILL- Composed of Sand and Clay, Fine to Coarse Grained Sand, Gravel in Areas, Dark Gray to Dark Brown CLAYEY SAND (SC) - Reddish Brown, Fine to Medium Grained Sand, Moist, Medium Stiff to Stiff SANDY CLAY (CL) - Silty in Parts, Reddish Brown, Fine to Medium Grained Sand, Moist, Stiff CLAYEY SAND (SC) - Tan, Fine to Coarse Grained Sand, Moist, Stiff PROJECT NO.: 0532395 PROJECT: 7-Eleven Depth, (feet) STRENGTH, tsf Additional Remarks USCS Classification 0 Qp Sample Type 2.0 0 Moisture, % SC 10 1 2 12 12 LL = 27 PL = 16 S(250) = 1.2% DD = 120 pcf LL = 44 PL = 16 -200 = 41.5% 7-7 N=14 6-10 N=16 ASPHALT - Approximately 3 Inches Thick MAN-MADE FILL- Composed of Sand and Clay, Fine to Coarse Grained Sand, Gravel in Areas, Dark Gray to Dark Brown CLAYEY SAND (SC) - Reddish Brown, Fine to Medium Grained Sand, Moist, Stiff PROJECT NO.: 0532395 PROJECT: 7-Eleven Depth, (feet) STRENGTH, tsf Additional Remarks USCS Classification 0 Qp Sample Type 2.0 0 Moisture, % Moisture MATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft Qu Sample No. Graphic Log 50 PL Elevation (feet) LL 4.0 25 Recovery (inches) BENCHMARK: N/A The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 1 DATE STARTED: 11/28/11 DRILL COMPANY: Dakota DATE COMPLETED: 11/28/11 STATION: N/A OFFSET: N/A LOGGED BY: CW COMPLETION DEPTH 5.0 ft DRILL RIG: CME-55 DRILLING METHOD: 4" Solid Stem Auger ELEVATION: 5124.2 ft SC 9 1 2 12 12 LL = 30 PL = 16 S(250) = 0.4% DD = 113 pcf LL = 37 PL = 14 -200 = 27.3% 3-3 N=6 4-6 N=10 ASPHALT - Approximately 3 Inches Thick MAN-MADE FILL- Composed of Sand and Clay, Fine to Coarse Grained Sand, Gravel in Areas, Dark Gray to Dark Brown CLAYEY SAND (SC) - Reddish Brown, Fine to Medium Grained Sand, Moist, Soft to Medium Stiff PROJECT NO.: 0532395 PROJECT: 7-Eleven Depth, (feet) STRENGTH, tsf Additional Remarks USCS Classification 0 Qp Sample Type 2.0 0 Moisture, % Moisture MATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft Qu Sample No. Graphic Log 50 PL Elevation (feet) LL 4.0 25 Recovery (inches) BENCHMARK: N/A The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 1 DATE STARTED: 11/28/11 DRILL COMPANY: Dakota DATE COMPLETED: 11/28/11 STATION: N/A OFFSET: N/A LOGGED BY: CW COMPLETION DEPTH 5.0 ft DRILL RIG: CME-55 DRILLING METHOD: 4" Solid Stem Auger Professional Service Industries, Inc. Asphalt KEY TO SYMBOLS PSI Job No.: Project: Location: 0532395 7-Eleven 3045 West Prospect Ft. Collins, CO Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Fax: (303) 423-5625 Fill Clayey Sand Sandy Clay SSA = Solid Stem Auger HSA = Hollow Stem Auger CFA = Continuous Flight Auger SPT = Standard Penetration Test MC - Modified California Sampler SS = Split-spoon Sampler ST = Shelby Tube Sampler RC = Rock Core DD = Dry Density MC = Moisture Content LL = Liquid Limit PL = Plastic Limit -200 = Percent Passing the No. 200 Sieve (%) S(250) = Swell under 250 psf surcharge pressure (%) S(500) = Swell under 500 psf surcharge pressure (%) S(1000) = Swell under 1000 psf surcharge pressure (%) Qu = Unconfined Compressive Strength RQD = Rock Quality Designation REC'D = Rock Core Recovery Percentage PID = Photo Ionic Detector (ppm) The borings were advanced into the ground using 4 inch solid stem augers. At regular intervals throughout the boring depths, soil samples were obtained with either a 1.4-inch I.D., 2.0-inch O.D., split-spoon sampler or a 2.0-inch I.D., 2.4-inch O.D. Modified California sampler. The samplers were first seated 6-inches to penetrate any loose cuttings and then driven an additional foot where possible with blows of a 140 pound hammer falling 30-inches. The number of hammer blows required to drive the sampler each 6-inch increment is recorded in the field. The penetration resistance "N-value" is redesignated as the number of hammer blows required to drive the sampler the final foot and, when properly evaluated, is an index to cohesion for clays and relative density for sands. The split-spoon sampling procedures used during this exploration are in general accordance with ASTM Designation D 1586. APPENDIX A Laboratory Test Results US SIEVE OPENING IN INCHES HYDROMETER GRAVEL SAND COBBLES COARSE FINE CRS MED FINE SILT OR CLAY Specimen I.D. Description USCS AASHTO Group Index LL PI PL B4 @ 0-5 FEET SC A-6 3 37 23 B3 @ 0-5 FEET CL A-7-6 11 44 28 Specimen I.D. D100 D60 D30 D10 Cc Cu %Gravel %Sand %Silt&Clay B4 @ 0-5 FEET 37.50 0.93 21 43 B3 @ 0-5 FEET 19.00 0.14 7 40 JOB NO. Clayey Sand Sandy Clay US SIEVE NUMBERS 7-Eleven - Fort Collins, CO GRADATION CURVES 0532395 FIGURE NO. A-1 14 53 16 36 0 10 20 30 40 50 60 70 80 90 100 1000 100 10 1 0.1 0.01 0.001 GRAIN SIZE (mm) % F I N E R by W E I G H T 1.5 3/4 3/8 4 10 16 30 40 100 200 118 pcf 2.5 feet 10.4 % Sample Description 0.3 % USCS Classification 1,000 psf JOB NO. FIGURE NO. Sample Location Sample Depth B2 Dry Density Moisture Content CL Sandy Clay 7-11 - Fort Collins SWELL - CONSOLIDATION TEST 532395 A-2 Volume Change Swell Pressure SWELL-CONSOLIDATION TEST -4 -2 0 2 4 6 8 10 100 1000 10000 100000 109 pcf 2 feet 9.2 % Sample Description 1.2 % USCS Classification 2,000 psf JOB NO. FIGURE NO. 7-11 - Fort Collins SWELL - CONSOLIDATION TEST 532395 A-3 Volume Change Swell Pressure Sample Location Sample Depth B3 Dry Density Moisture Content CL Sandy Clay SWELL-CONSOLIDATION TEST -4 -2 0 2 4 6 8 10 100 1000 10000 100000 113 pcf 2 feet 14.8 % Sample Description 0.4 % USCS Classification 1,400 psf JOB NO. FIGURE NO. Volume Change Swell Pressure Sample Location Sample Depth B4 Dry Density Moisture Content CL Sandy Clay 7-11 - Fort Collins SWELL - CONSOLIDATION TEST 532395 A-4 SWELL-CONSOLIDATION TEST -4 -2 0 2 4 6 8 10 100 1000 10000 100000 ELEVATION: 5123.4 ft REVIEWED BY: See Figure No. 2 EFFICIENCY N/A East Parking lot Area HAMMER TYPE: Manual BORING LOCATION: 0 5 N/A While Drilling Upon Completion Delay 5120 LATITUDE: 40.567723° LONGITUDE: -105.133262° FIGURE: 6 LOCATION: 3045 West Prospect Not Encountered Not Encountered Water REMARKS: DRILLER: Nick BORING B4 Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Ft. Collins, CO SAMPLING METHOD: Modified California REVIEWED BY: See Figure No. 2 EFFICIENCY N/A South Parking Lot Area HAMMER TYPE: Manual BORING LOCATION: 0 5 N/A While Drilling Upon Completion Delay 5120 LATITUDE: 40.567723° LONGITUDE: -105.133262° FIGURE: 5 LOCATION: 3045 West Prospect Not Encountered Not Encountered Water REMARKS: DRILLER: Nick BORING B3 Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Ft. Collins, CO SAMPLING METHOD: Modified California Moisture MATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft Qu Sample No. Graphic Log 50 PL Elevation (feet) LL 4.0 25 Recovery (inches) BENCHMARK: N/A The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 1 DATE STARTED: 11/28/11 DRILL COMPANY: Dakota DATE COMPLETED: 11/28/11 STATION: N/A OFFSET: N/A LOGGED BY: CW COMPLETION DEPTH 20.0 ft DRILL RIG: CME-55 DRILLING METHOD: 4" Solid Stem Auger ELEVATION: 5122.8 ft REVIEWED BY: See Figure No. 2 EFFICIENCY N/A Northeast Corner of Building HAMMER TYPE: Manual BORING LOCATION: 0 5 10 15 20 N/A While Drilling Upon Completion Delay 5120 5115 5110 5105 LATITUDE: 40.567723° LONGITUDE: -105.133262° FIGURE: 4 LOCATION: 3045 West Prospect Not Encountered Not Encountered Water REMARKS: DRILLER: Nick BORING B2 Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Ft. Collins, CO SAMPLING METHOD: Modified California Qp Sample Type 2.0 0 Moisture, % Moisture MATERIAL DESCRIPTION STANDARD PENETRATION TEST DATA N in blows/ft Qu Sample No. Graphic Log 50 PL Elevation (feet) LL 4.0 25 Recovery (inches) BENCHMARK: N/A The stratification lines represent approximate boundaries. The transition may be gradual. Sheet 1 of 1 DATE STARTED: 11/28/11 DRILL COMPANY: Dakota DATE COMPLETED: 11/28/11 STATION: N/A OFFSET: N/A LOGGED BY: CW COMPLETION DEPTH 20.0 ft DRILL RIG: CME-55 DRILLING METHOD: 4" Solid Stem Auger ELEVATION: 5123.5 ft REVIEWED BY: See Figure No. 2 EFFICIENCY N/A Southwest Corner of Building HAMMER TYPE: Manual BORING LOCATION: 0 5 10 15 20 N/A While Drilling Upon Completion Delay 5120 5115 5110 5105 LATITUDE: 40.567723° LONGITUDE: -105.133262° FIGURE: 3 LOCATION: 3045 West Prospect Not Encountered Not Encountered Water REMARKS: DRILLER: Nick BORING B1 Professional Service Industries, Inc. 1070 West 124th Avenue, Suite 800 Westminster, CO 80234 Telephone: (303) 424-5578 Ft. Collins, CO SAMPLING METHOD: Modified California