HomeMy WebLinkAboutOAK 140 - FDP200022 - SUBMITTAL DOCUMENTS - ROUND 1 - SUPPORTING DOCUMENTATION (2)TOTAL FIXTURE FIXTURE NO. VALUE VALUE OF AT AT FIXTURE DESCRIPTION FIXTURES 60 PSI 60 PSI WATER CLOSET (PUBLIC, GENERAL USE, FLUSH TANK) 4 6 24 LAVATORY (PUBLIC, GENERAL USE) 4 0.5 2 DRINKING FOUNTAIN (PUBLIC, GENERAL USE) 4 2 8 KITCHEN SINK/DISPOSAL/DISHWASHER (PUBLIC, GENERAL USE) 2 3.1 6.2 MOP SINK (PUBLIC, GENERAL USE) 2 4 8 COMBINED FIXTURE VALUE TOTAL 48.2 CUSTOMER PEAK DEMAND FROM FIGURE 4-2 OR 4-3 COMMERCIAL HOTELS, RETAIL, RESTAURANTS, PUBLIC BUILDINGS (GPM) 44 PRESSURE FACTOR FROM TABLE 4-1 1 IRRIGATION LOAD (GPM) 0 ADDED FIXED LOAD (GPM) 0 TOTAL MAXIMUM PEAK DEMAND (GPM) 44 SITE WATER PRESSURE AVAILABLE (PSI) 95 SERVICE PRESSURE TO BUILDING (PSI) 70 MAXIMUM ALLOWABLE HEAD LOSS IN SERVICE (PSI) 25 PRV LOSSES AT TOTAL FIXED DEMAND (PSI) 5 TAP AND METER SERVICE SIZE (INCHES) 1 WATER METER PRESSURE LOSS AT TOTAL FIXED DEMAND (PSI) 5 REDUCED PRESSURE BACKFLOW PREVENTION ASSEMBLY LOSSES AT TOTAL FIXED DEMAND (PSI) 12 TOTAL EQUIVILANT LENGTH OF SERVICE PIPING FROM TAP TO BUILDING SERVICE (FEET) 50 MISC. PIPING LOSSES FROM TAP TO BUILDING SERVICE (PSI) 30.34 TOTAL HEAD LOSS FROM TAP TO BUILDING SERVICE 52.34 SPARK - 140 OAK ST - COMMERCIAL DOMESTIC WATER SERVICE SIZING 2014 AWWA M22 CRITERIA TOTAL FIXTURE FIXTURE NO. VALUE VALUE OF AT AT FIXTURE DESCRIPTION FIXTURES 60 PSI 60 PSI WATER CLOSET (PUBLIC, GENERAL USE, FLUSH TANK) 4 6 24 LAVATORY (PUBLIC, GENERAL USE) 5 0.5 2.5 DRINKING FOUNTAIN (PUBLIC, GENERAL USE) 2 2 4 PRIVATE FLUSH TANK BATHROOM GROUP (PRIVATE, 3 OR MORE DWELLINGS, TUB) 79 14.5 1145.5 KITCHEN SINK/DISPOSAL/DISHWASHER (PRIVATE, 3 OR MORE DWELLINGS) 79 3.1 244.9 KITCHEN SINK/DISPOSAL/DISHWASHER (PUBLIC, GENERAL USE) 1 3.1 3.1 CLOTHESWASHER (PRIVATE, 3 OR MORE DWELLINGS) 79 3 237 MOP SINK (PUBLIC, GENERAL USE) 1 4 4 HOSE BIBB (PUBLIC, GENERAL USE, FIRST UNIT) 1 12 12 HOSE BIBB (PUBLIC, GENERAL USE, EACH ADDITIONAL UNIT) 3 12 36 COMBINED FIXTURE VALUE TOTAL 1723 CUSTOMER PEAK DEMAND FROM FIGURE 4-2 OR 4-3 RESIDENTIAL APARTMENTS, MOTELS, CONDOS (GPM) 68 PRESSURE FACTOR FROM TABLE 4-1 1 IRRIGATION LOAD (GPM) 20 ADDED FIXED LOAD (GPM) 0 TOTAL MAXIMUM PEAK DEMAND (GPM) 88 SITE WATER PRESSURE AVAILABLE (PSI) 95 SERVICE PRESSURE TO BUILDING (PSI) 80 MAXIMUM ALLOWABLE HEAD LOSS IN SERVICE (PSI) 15 PRV LOSSES AT TOTAL FIXED DEMAND (PSI) 5 TAP AND METER SERVICE SIZE (INCHES) 1.5 WATER METER PRESSURE LOSS AT TOTAL FIXED DEMAND (PSI) 5 REDUCED PRESSURE BACKFLOW PREVENTION ASSEMBLY LOSSES AT TOTAL FIXED DEMAND (PSI) 12 TOTAL EQUIVILANT LENGTH OF SERVICE PIPING FROM TAP TO BUILDING SERVICE (FEET) 50 MISC. PIPING LOSSES FROM TAP TO BUILDING SERVICE (PSI) 15.10 TOTAL HEAD LOSS FROM TAP TO BUILDING SERVICE 37.10 SPARK - 140 OAK ST - RESIDENTIAL DOMESTIC WATER SERVICE SIZING 2014 AWWA M22 CRITERIA