HomeMy WebLinkAboutRIDGEWOOD HILLS FIFTH FILING - PDP190018 - SUBMITTAL DOCUMENTS - ROUND 4 - ARCHITECTURAL DETAILSW/D W/D REF. DW REF. DW W/D W/D REF. DW REF. DW DW REF. W/D DW REF. W/D W/D W/D DW REF. REF. DW 1 2 3 4 5 6 7 8 9 502 SF SMALL 1 BED. 898 SF MEDIUM 2 BED. 377 SF STUDIO 551 SF MEDIUM 1 BED. 551 SF MEDIUM 1 BED. 502 SF SMALL 1 BED. 1,460 SF SMALL 2 BED. ? ? A B C D 101'-8" Redundant Room SMALL 2 BED. MECH. H2O 62'-0" MECH. N 3'-11 7/8" Sheet Sheet Name Checked By: REF. DW REF. DW W/D W/D REF. DW W/D W/D REF. DW UP DW REF. W/D DW REF. W/D W/D W/D DW REF. DW REF. 1 2 3 4 5 6 7 8 9 502 SF SMALL 1 BED. 502 SF SMALL 1 BED. 898 SF MEDIUM 2 BED. 551 SF MEDIUM 1 BED. A B C D 4'-0" 655 SF LARGE 1 BED. 377 SF STUDIO 1,460 SF SMALL 2 BED. Redundant Room SMALL 2 BED. 6" N Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW REF. DW REF. DW W/D W/D REF. DW W/D W/D REF. DW DW REF. W/D DW REF. W/D W/D W/D DW REF. DW REF. 1 2 3 4 5 6 7 8 9 A B C D 1,007 SF SMALL 1 BED. Redundant Room SMALL 1 BED. 551 SF MEDIUM 1 BED. 655 SF LARGE 1 BED. SMALL 2 BED. SMALL 2 BED. STUDIO MEDIUM 2 BED. 62'-0" 101'-8" N Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL 3 12 ARCHITECTURAL GRADE METAL PANEL - ACCENT 01 COMPOSITE WOOD SCREEN ADHERED MASONRY, TYP. STUCCO - ACCENT 02 VINYL WINDOW, TYP. LAP SIDING - BODY 01, TYP. METAL RAILING - TRIM 01, TYP. LAP SIDING - BODY 02 METAL PARAPET CAP - TRIM 01, TYP. 1X4 STUCCO TRIM - TRIM 01, TYP. WALL-MOUNTED HVAC UNIT, TYP. 5/4 HARDBOARD TRIM - TRIM 01, TYP. 2 12 PAINTED STEEL AWNING - TRIM 02 ALUMINUM STOREFRONT OVERALL BUILDING HEIGHT 40'-0" 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL 3:12 ARCHITECTURAL GRADE METAL PANEL - ACCENT 01 METAL RAILING - TRIM 01, TYP. LAP SIDING - BODY 01, TYP. ADHERED MASONRY, TYP. STUCCO - ACCENT 02 VINYL WINDOW, TYP. STANDING SEAM METAL ROOF COMPOSITE WOOD SCREEN 2X12 FASCIA BOARD - TRIM 01 UTILITY METERS, RE: CIVIL 1X4 STUCCO TRIM - TRIM 01, TYP. PAINTED WOOD CORBELS - TRIM 01 OVERALL BUILDING HEIGHT 40'-0" METAL PARAPET W/D REF. DW W/D DW W/D W/D REF. DW REF. DW REF. W/D DW W/D REF. W/D REF. DW DW REF. W/D W/D W/D REF. DW REF. DW W/D REF. DW W/D DW REF. DW W/D REF. DW REF. DW REF. W/D 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 375 SF END STUDIO 666 SF LARGE 1 BED. 562 SF MEDIUM 1 BED. 376 SF STUDIO 999 SF LARGE 2 BED. 666 SF LARGE 1 BED. 1,001 SF LARGE 2 BED. 1,000 SF LARGE 2 BED. W/D REF. DW W/D REF. DW DW REF. W/D DW REF. W/D W/D W/D W/D DW W/D REF. DW W/D REF. REF. DW W/D W/D W/D DW REF. DW REF. W/D DW REF. DW REF. REF. DW DW REF. W/D DW REF. W/D DW REF. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 375 SF END STUDIO 1,000 SF LARGE 2 BED. 989 SF LARGE 2 BED. 1,002 SF LARGE 2 BED. 1,000 SF LARGE 2 BED. 1,000 SF LARGE 2 BED. 666 SF W/D REF. DW W/D REF. DW W/D W/D W/D W/D W/D W/D W/D W/D W/D W/D W/D DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 375 SF END STUDIO 375 SF END STUDIO 727 SF SMALL 2 BED. 1,001 SF LARGE 2 BED. 998 SF LARGE 2 BED. 1,000 SF LARGE 2 BED. 1,061 SF 3 BED 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL 2 12 OVERALL BUILDING HEIGHT 40'-0" LAP SIDING - BODY 02 VERTICAL SIDING - BODY 03, TYP. METAL PANEL - ACCENT 01, TYP. COMPOSITE WOOD SCREEN ADHERED MASONRY, TYP. STUCCO - ACCENT 02 STANDING SEAM METAL ROOF 5/4 HARDBOARD TRIM - TRIM 01, TYP. LAP SIDING - BODY 01, TYP. METAL RAILING - TRIM 01, TYP. PAINTED WOOD CORBELS - TRIM 01 METAL PARAPET CAP - TRIM 01, TYP. WALL- MOUNTED HVAC UNIT, TYP. VINYL WINDOW, TYP. 1X4 STUCCO TRIM - TRIM 01, TYP. UTILITY METERS, RE: CIVIL BODY 01 BODY 02 BODY 03 ACCENT 01 ACCENT 02 TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) AGED COPPER (CMG METALS) CASCADE WHITE (BM 2127-70) CORONADO PROLEDGE - HURON COMPOSITE WOOD TREX - SPICED RUM * ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) ARCHITECTURAL GRADE METAL PANEL LAP SIDING LAP SIDING VERTICAL SIDING STUCCO 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL OVERALL BUILDING HEIGHT 39'-7" LAP SIDING - BODY 02 VERTICAL SIDING - BODY 03, TYP. METAL PANEL - ACCENT 01 COMPOSITE WOOD SCREEN ADHERED MASONRY, TYP. STUCCO - ACCENT 02 STANDING SEAM METAL ROOF VINYL WINDOW, TYP. LAP SIDING - BODY 01, TYP. METAL PARAPET 5/4 HARDBOARD CAP - TRIM 01 TRIM - TRIM 01, TYP. METAL RAILING - TRIM 01, TYP. PAINTED WOOD CORBELS - TRIM 01 1X4 STUCCO TRIM - TRIM 01, TYP. WALL-MOUNTED HVAC UNIT, TYP. 2X12 FASCIA BOARD - TRIM 01, TYP. PAINTED STEEL AWNING - TRIM 01, TYP. UTILITY METERS, RE: CIVIL BODY 01 BODY 02 BODY 03 ACCENT 01 ACCENT 02 TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) AGED COPPER (CMG METALS) CASCADE WHITE (BM 2127-70) CORONADO PROLEDGE - HURON COMPOSITE WOOD TREX - SPICED RUM * ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) ARCHITECTURAL GRADE METAL PANEL LAP SIDING LAP SIDING VERTICAL SIDING STUCCO 1ST LEVEL 100'-0" 2ND LEVEL W/D W/D DW REF. REF. DW W/D DW REF. W/D W/D DW REF. REF. DW W/D DW W/D REF. DW REF. W/D DW REF. DW REF. W/D W/D DW REF. W/D DW REF. W/D DW REF. W/D DW REF. W/D DW REF. W/D DW W/D REF. DW REF. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 A B C D 27'-6" 7'-0" 27'-6" 4'-0" 64'-4" 4'-0" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 551 SF MEDIUM 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. W/D W/D REF. DW DW REF. REF. DW DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. W/D W/D W/D W/D W/D W/D W/D W/D W/D W/D W/D DW REF. W/D W/D DW REF. DW REF. W/D 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 A B C D 27'-6" 7'-0" 27'-6" 68'-4" 4'-0" 4'-0" 216'-0 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 502 SF SMALL 1 BED. 502 SF SMALL 1 BED. 551 SF MEDIUM 1 BED. W/D W/D W/D W/D W/D W/D W/D W/D W/D W/D W/D W/D W/D DW REF. W/D W/D DW REF. W/D REF. DW DW REF. REF. DW DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. DW REF. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 A B C D 502 SF SMALL 1 BED. 502 SF SMALL 1 BED. 551 SF MEDIUM 1 BED. 551 SF MEDIUM 1 BED. 1,332 SF LARGE 1 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL VERTICAL SIDING - BODY 03 ADHERED MASONRY, TYP. COMPOSITE WOOD SCREEN ADHERED MASONRY, TYP. STUCCO - ACCENT 02 1X4 STUCCO TRIM - TRIM 01, TYP. METAL PANEL - ACCENT 01 METAL RAILING - TRIM 02, TYP. LAP SIDING - BODY 01 METAL PARAPET CAP - TRIM 01, TYP. OVERALL BUILDING HEIGHT 40'-0" WALL-MOUNTED HVAC UNIT, TYP. VINYL WINDOW, TYP. PAINTED WOOD CORBELS - TRIM 01, TYP. STANDING SEAM METAL ROOF 2X12 FASCIA BOARD - TRIM 01, TYP. PAINTED STEEL AWNING - TRIM 02 2X4 STUCCO TRIM - TRIM 02 5/4 HARDBOARD TRIM - TRIM 01, TYP. 2 12 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL VERTICAL SIDING - BODY 03 ADHERED MASONRY, TYP. VINYL WINDOW, TYP. 5/4 HARDBOARD TRIM - TRIM 01 STANDING SEAM METAL ROOF 1X4 STUCCO TRIM - TRIM 01, TYP. METAL PANEL - ACCENT 01 STUCCO - ACCENT 02 OVERALL BUILDING HEIGHT 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL METAL PANEL - ACCENT 01 COMPOSITE WOOD SCREEN ADHERED MASONRY, TYP. STUCCO - ACCENT 02 VINYL WINDOW, TYP. LAP SIDING - BODY 01, TYP. METAL RAILING - TRIM 01, TYP. LAP SIDING - BODY 02 METAL PARAPET CAP - TRIM 01, TYP. METAL PANEL - ACCENT 01 1X4 STUCCO TRIM - TRIM 01, TYP. WALL-MOUNTED HVAC UNIT, TYP. 5/4 HARDBOARD TRIM - TRIM 01, TYP. PAINTED WOOD CORBELS - TRIM 01, TYP. 2X12 FASCIA BOARD - TRIM 01, TYP. STANDING SEAM METAL ROOF OVERALL BUILDING HEIGHT 40'-0" 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL VERTICAL SIDING - BODY 03 METAL RAILING - TRIM 01, TYP. LAP SIDING - BODY 01, TYP. ADHERED MASONRY, TYP. STUCCO - ACCENT 02 VINYL WINDOW, TYP. STANDING SEAM METAL ROOF METAL PANEL - ACCENT 01 COMPOSITE WOOD SCREEN 2X12 FASCIA BOARD - TRIM 01 UTILITY METERS, RE: CIVIL 5/4 HARDBOARD TRIM - TRIM 01, TYP. PAINTED WOOD CORBELS - TRIM 01 OVERALL BUILDING HEIGHT 40'-0" BODY 01 BODY 02 BODY 03 ACCENT 01 ACCENT 02 FITNESS ENTRY MECH GAME ROOM KITCHEN GATHERING ROOM MEN'S WOMEN'S MECH JANITOR STORAGE LEASING OFFICE BUSINESS CENTER 47'-2" 20'-10 1/2" 12'-2" 11'-7 1/2" POOL EQUIP. CORRIDOR 86'-3 1/2" 1'-6" 13'-2 1/2" 28'-0 1/2" 18'-0" 25'-6 1/2" 17'-3 1/2" 13'-2 1/2" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION CLUBHOUSE PLAN A1.60 3/16" = 1'-0" 1 FIRST FLOOR N 1ST LEVEL 100'-0" OVERALL BUILDING HEIGHT 20'-10 3/4" 1 12 1 12 LAP SIDING - BODY 01 STANDING SEAM METAL ROOF 2X12 FASCIA BOARD - TRIM 01 PAINTED WOOD CORBELS - TRIM 01 ALUMINUM STOREFRONT PAINTED STEEL AWNING - TRIM 01, TYP. LAP SIDING - BODY 02 ADHERED MASONRY, TYP. METAL PANEL - ACCENT 01, TYP. 1X4 STUCCO TRIM BODY 01 BODY 02 BODY 03 ACCENT 01 ACCENT 02 TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) AGED COPPER (CMG METALS) CASCADE WHITE (BM 2127-70) CORONADO PROLEDGE - HURON COMPOSITE WOOD TREX - SPICED RUM • ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. • ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) ARCHITECTURAL GRADE METAL PANEL LAP SIDING LAP SIDING VERTICAL SIDING STUCCO 1ST LEVEL 100'-0" 1 12 1 12 1 12 LAP SIDING - BODY 01 STANDING SEAM METAL ROOF LAP SIDING - BODY 02 ALUMINUM STOREFRONT METAL PANEL - 1ST LEVEL 100'-0" OVERALL BUILDING HEIGHT 20'-10 3/4" 1:12 1:12 METAL PANEL - ACCENT 01 2X12 FASCIA BOARD - TRIM 01 ALUMINUM STOREFRONT VERTICAL SIDING - BODY 03 ADHERED MASONRY, TYP. 1X4 STUCCO TRIM VINYL WINDOW, TYP. LAP SIDING - BODY 01 STANDING SEAM METAL ROOF PAINTED WOOD CORBELS - TRIM 01 BODY 01 BODY 02 BODY 03 ACCENT 01 ACCENT 02 TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) AGED COPPER (CMG METALS) CASCADE WHITE (BM 2127-70) CORONADO PROLEDGE - HURON COMPOSITE WOOD TREX - SPICED RUM • ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. • ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) ARCHITECTURAL GRADE METAL PANEL LAP SIDING LAP SIDING VERTICAL SIDING STUCCO 1ST LEVEL 100'-0" 1 12 1:12 1 12 LAP SIDING - BODY 01 VERTICAL SIDING - BODY 03, TYP. STANDING SEAM METAL ROOF 2X12 FASCIA BOARD - 1a 2a 3a 4a 5a 6a A B 21'-8" 2'-0" 10'-10" 10'-4 1/2" 10'-4 1/2" 10'-4 1/2" 10'-10" FRAME WALL CENTERED ON CONCRETE CURB BELOW 3 1/2" 5'-6" 5'-0 1/2" 3 1/2" 5'-0 1/2" 5'-0 1/2" 3 1/2" 5'-0 1/2" 5'-0 1/2" 3 1/2" 5'-0 1/2" 5'-0 1/2" 3 1/2" 5'-0 1/2" 5'-2 1/2" 3 1/2" 31'-10 1/2" 20'-11" 52'-9 1/2" 2'-0" TYPICAL TOP OF CURB ELEVATION AT PERIMETER AND DIVIDING WALLS (6" ABOVE TOP OF SLAB ELEVATION AT OHD) TYPICAL TOP OF SLAB ELEVATION AT BACK OF GARAGE (2" BELOW TOP OF CURB) TYPICAL TOP OF SLAB ELEVATION AT FRONT OF GARAGE/OHD (6" BELOW TOP OF CURB). REFER TO CIVIL GRADING FOR USGS ELEVATIONS AND FINISH FLOOR ELEVATIONS RELATIVE TO 100'-0" (FFE = 100'-0", TYP.) RE: CIVIL GRADING AND STRUCTURAL FOUNDATION PLANS FOR SLAB/CURB STEPPING LOCATIONS AND ELEVATIONS. *THIS PLAN SHOWN WITHOUT STEPS RELATIVE TO 100'-0". STEPS AT FFE RESULT IN STEPS AT TOP OF CURB, WALLS, ROOF, ETC. SLAB SLOPED TO DRAIN TOWARDS OVERHEAD DOORS. RE: SPOT ELEVATIONS (APPROXIMATELY 1/4"/1'-0" SLOPE), TYP. 1a 2a 3a 4a 5a 6a A B 52'-9 1/2" 1'-10 7/8" 21'-9 5/8" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA ROOF PLAN NOTES • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS. ALL SOFFITS ARE TO BE FLAT, U.N.O. • ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER THE SUPERVISION OF A COLORADO LICENSED STRUCTURAL ENGINEER. • ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES. PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO CONNECT ROOF AREAS. • PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO PROVIDE ATTIC VENTILATION AS REQUIRED PER 2015 IBC SECTION 1203. RE: ROOF VENTING NOTES AND CALCULATIONS. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2015 IPC SECTION 305.5. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2015 IPC SECTION 315. WHERE APPLICABLE, PENETRATIONS IN FIRE-RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH 2015 IBC SECTION 714. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. 2015 INTERNATIONAL BUILDING CODE • ROOF ASSEMBLIES PER 2015 IBC CHAPTER 1501: ROOF ASSEMBLIES SHALL PROVIDE A WEATHER RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER PROTECTION PER 2015 IBC SECTION 1503 AND ROOF COVERINGS PER SECTION 1507. RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION. • CRICKETS AND SADDLES SHALL BE INSTALLED AT THE REQUIRED LOCATIONS PER 2015 IBC SECTION 1503.6. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE SAME MATERIAL AS THE ROOF COVERING. PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE TO THE CRICKET OR SADDLE SLOPE. • LOW SLOPE ROOFS - ASPHALT SHINGLES: ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2015 IBC SECTION 1507.2.8. • AN ICE BARRIER SHALL BE INSTALLED AT EAVES, EXTENDING FROM THE LOWEST EDGE TO A POINT AT LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2015 IBC SECTION 1507.2.8.2 OR AS REQUIRED BY LOCAL AMENDMENTS. • METAL ROOF PANELS: THE INSTALLATION, ATTACHMENT, AND UNDERLAYMENT REQUIREMENTS OF METAL ROOF PANELS SHALL COMPLY WITH 2015 IBC SECTION 1507.4. • ROOF DRAINAGE PER 2015 IPC SECTION 1106: SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER BUILDER'S SPECIFICATION, SHALL BE IN COMPLIANCE WITH SECTION 1106 BASED ON THE RAINFALL RATE AND 21'-2 1/2" 10'-4 1/2" 10'-4 1/2" 18'-1 1/2" ACCESS AISLE 8'-0" VAN PARKING STALL 8'-0" C D 1b 2b 3b 4b 5b 6b 10'-10" 10'-4 1/2" 10'-4 1/2" 10'-4 1/2" 18'-1 1/2" 10'-10" 10'-4 1/2" 10'-4 1/2" 10'-4 1/2" 18'-1 1/2" 60'-1" 21'-8" RE: CIVIL GRADING AND STRUCTURAL FOUNDATION PLANS FOR SLAB/CURB STEPPING LOCATIONS AND ELEVATIONS. *THIS PLAN SHOWN WITHOUT STEPS RELATIVE TO 100'-0". STEPS AT FFE RESULT IN STEPS AT TOP OF CURB, WALLS, ROOF, ETC. TYPICAL TOP OF CURB ELEVATION AT PERIMETER AND DIVIDING WALLS (6" ABOVE TOP OF SLAB ELEVATION AT OHD) TYPICAL TOP OF SLAB ELEVATION AT BACK OF GARAGE (2" BELOW TOP OF CURB) TYPICAL TOP OF SLAB ELEVATION AT FRONT OF GARAGE/OHD (6" BELOW TOP OF CURB). REFER TO CIVIL GRADING FOR USGS ELEVATIONS AND FINISH FLOOR ELEVATIONS RELATIVE TO 100'-0" (FFE = 100'-0", TYP.) SLAB SLOPED TO DRAIN TOWARDS OVERHEAD DOORS. RE: SPOT ELEVATIONS (APPROXIMATELY 1/4"/1'-0" SLOPE), TYP. C D 1b 2b 3b 4b 5b 6b 60'-1" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL ROOF PLAN NOTES • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS. ALL SOFFITS ARE TO BE FLAT, U.N.O. • ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER THE SUPERVISION OF A COLORADO LICENSED STRUCTURAL ENGINEER. • ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES. PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO CONNECT ROOF AREAS. • PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO PROVIDE ATTIC VENTILATION AS REQUIRED PER 2015 IBC SECTION 1203. RE: ROOF VENTING NOTES AND CALCULATIONS. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2015 IPC SECTION 305.5. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2015 IPC SECTION 315. WHERE APPLICABLE, PENETRATIONS IN FIRE-RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH 2015 IBC SECTION 714. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. 2015 INTERNATIONAL BUILDING CODE • ROOF ASSEMBLIES PER 2015 IBC CHAPTER 1501: ROOF ASSEMBLIES SHALL PROVIDE A WEATHER RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER PROTECTION PER 2015 IBC SECTION 1503 AND ROOF COVERINGS PER SECTION 1507. RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION. • CRICKETS AND SADDLES SHALL BE INSTALLED AT THE REQUIRED LOCATIONS PER 2015 IBC SECTION 1503.6. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE SAME MATERIAL AS THE ROOF COVERING. PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE TO THE CRICKET OR SADDLE SLOPE. • LOW SLOPE ROOFS - ASPHALT SHINGLES: ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2015 IBC SECTION 1507.2.8. • AN ICE BARRIER SHALL BE INSTALLED AT EAVES, EXTENDING FROM THE LOWEST EDGE TO A POINT AT LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2015 IBC SECTION 1507.2.8.2 OR AS REQUIRED BY LOCAL AMENDMENTS. • METAL ROOF PANELS: THE INSTALLATION, ATTACHMENT, AND UNDERLAYMENT REQUIREMENTS OF METAL ROOF PANELS SHALL COMPLY WITH 2015 IBC SECTION 1507.4. • ROOF DRAINAGE PER 2015 IPC SECTION 1106: SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER BUILDER'S SPECIFICATION, SHALL BE IN COMPLIANCE WITH SECTION 1106 BASED ON THE RAINFALL RATE AND 21'-8" 1c 2c 3c 4c 5c E F 10'-10" 20'-9" 10'-10" 10'-10" 10'-4 1/2" 10'-4 1/2" 10'-10" 42'-5" TYPICAL TOP OF CURB ELEVATION AT PERIMETER AND DIVIDING WALLS (6" ABOVE TOP OF SLAB ELEVATION AT OHD) TYPICAL TOP OF SLAB ELEVATION AT BACK OF GARAGE (2" BELOW TOP OF CURB) TYPICAL TOP OF SLAB ELEVATION AT FRONT OF GARAGE/OHD (6" BELOW TOP OF CURB). REFER TO CIVIL GRADING FOR USGS ELEVATIONS AND FINISH FLOOR ELEVATIONS RELATIVE TO 100'-0" (FFE = 100'-0", TYP.) RE: CIVIL GRADING AND STRUCTURAL FOUNDATION PLANS FOR SLAB/CURB STEPPING LOCATIONS AND ELEVATIONS. *THIS PLAN SHOWN WITHOUT STEPS RELATIVE TO 100'-0". STEPS AT FFE RESULT IN STEPS AT TOP OF CURB, WALLS, ROOF, ETC. SLAB SLOPED TO DRAIN TOWARDS OVERHEAD DOORS. RE: SPOT ELEVATIONS (APPROXIMATELY 1/4"/1'-0" SLOPE), TYP. 1c 2c 3c 4c 5c E F 42'-5" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE C PLANS 1/4" = 1'-0" A1.74 ROOF PLAN NOTES • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS. ALL SOFFITS ARE TO BE FLAT, U.N.O. • ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER THE SUPERVISION OF A COLORADO LICENSED STRUCTURAL ENGINEER. • ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES. PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO CONNECT ROOF AREAS. • PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO PROVIDE ATTIC VENTILATION AS REQUIRED PER 2015 IBC SECTION 1203. RE: ROOF VENTING NOTES AND CALCULATIONS. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2015 IPC SECTION 305.5. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2015 IPC SECTION 315. WHERE APPLICABLE, PENETRATIONS IN FIRE-RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH 2015 IBC SECTION 714. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. 2015 INTERNATIONAL BUILDING CODE • ROOF ASSEMBLIES PER 2015 IBC CHAPTER 1501: ROOF ASSEMBLIES SHALL PROVIDE A WEATHER RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER PROTECTION PER 2015 IBC SECTION 1503 AND ROOF COVERINGS PER SECTION 1507. RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION. • CRICKETS AND SADDLES SHALL BE INSTALLED AT THE REQUIRED LOCATIONS PER 2015 IBC SECTION 1503.6. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE SAME MATERIAL AS THE ROOF COVERING. PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE TO THE CRICKET OR SADDLE SLOPE. • LOW SLOPE ROOFS - ASPHALT SHINGLES: ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2015 IBC SECTION 1507.2.8. • AN ICE BARRIER SHALL BE INSTALLED AT EAVES, EXTENDING FROM THE LOWEST EDGE TO A POINT AT LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2015 IBC SECTION 1507.2.8.2 OR AS REQUIRED BY LOCAL AMENDMENTS. • METAL ROOF PANELS: THE INSTALLATION, ATTACHMENT, AND UNDERLAYMENT REQUIREMENTS OF METAL ROOF PANELS SHALL COMPLY WITH 2015 IBC SECTION 1507.4. • ROOF DRAINAGE PER 2015 IPC SECTION 1106: SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER BUILDER'S SPECIFICATION, SHALL BE IN COMPLIANCE WITH SECTION 1106 BASED ON THE RAINFALL RATE AND G H 1d 2d 3d 4d 5d 47'-8 1/2" 21'-8" 10'-10" 10'-4 1/2" 10'-4 1/2" 16'-1 1/2" ACCESS AISLE 5'-0" PARKING STALL 8'-0" 10'-10" 10'-4 1/2" 10'-4 1/2" 16'-1 1/2" 47'-8 1/2" G H 1d 2d 3d 4d 5d 47'-8 1/2" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE D PLANS 1/4" = 1'-0" A1.76 1 GARAGE D - 1ST LEVEL 1/4" = 1'-0" 2 GARAGE D - SLAB PLAN G H 1d 2d 3d 4d 5d ROOF PLAN NOTES • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS. ALL SOFFITS ARE TO BE FLAT, U.N.O. • ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER THE SUPERVISION OF A COLORADO LICENSED STRUCTURAL ENGINEER. • ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES. PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO CONNECT ROOF AREAS. • PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO PROVIDE ATTIC VENTILATION AS REQUIRED PER 2015 IBC SECTION 1203. RE: ROOF VENTING NOTES AND CALCULATIONS. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2015 IPC SECTION 305.5. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2015 IPC SECTION 315. WHERE APPLICABLE, PENETRATIONS IN FIRE-RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH 2015 IBC SECTION 714. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. 2015 INTERNATIONAL BUILDING CODE • ROOF ASSEMBLIES PER 2015 IBC CHAPTER 1501: ROOF ASSEMBLIES SHALL PROVIDE A WEATHER RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER PROTECTION PER 2015 IBC SECTION 1503 AND ROOF COVERINGS PER SECTION 1507. RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION. • CRICKETS AND SADDLES SHALL BE INSTALLED AT THE REQUIRED LOCATIONS PER 2015 IBC SECTION 1503.6. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE SAME MATERIAL AS THE ROOF COVERING. PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE TO THE CRICKET OR SADDLE SLOPE. • LOW SLOPE ROOFS - ASPHALT SHINGLES: ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2015 IBC SECTION 1507.2.8. • AN ICE BARRIER SHALL BE INSTALLED AT EAVES, EXTENDING FROM THE LOWEST EDGE TO A POINT AT LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2015 IBC SECTION 1507.2.8.2 OR AS REQUIRED BY LOCAL AMENDMENTS. • METAL ROOF PANELS: THE INSTALLATION, ATTACHMENT, AND UNDERLAYMENT REQUIREMENTS OF METAL ROOF PANELS SHALL COMPLY WITH 2015 IBC SECTION 1507.4. • ROOF DRAINAGE PER 2015 IPC SECTION 1106: 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 02 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 OVERALL BUILDING HEIGHT 13'-1 1/4" COMPOSITION ROOF SHINGLES 2:12 8'-0" OVERHEAD DOOR - TRIM 01 LAP SIDING - BODY 01 1ST LEVEL 100'-0" T.O. CURB 100'-6" COMPOSITION ROOF SHINGLES LAP SIDING - BODY 01 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - LAP SIDING - TRIM 01 BODY 02 COMPOSITE WOOD SIDING 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 01 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 2 12 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 02 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 2 12 BODY 01 BODY 02 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 02 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 COMPOSITION ROOF SHINGLES 8'-0" OVERHEAD DOOR - TRIM 01 *ALL GARAGES TO MATCH MATERIALS AND COLORS, TYP. LAP SIDING - BODY 01 OVERALL BUILDING HEIGHT 13'-1 1/4" 2:12 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 02 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 2 12 2 12 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 01 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 2 12 2 12 1ST LEVEL 100'-0" T.O. CURB 100'-6" ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 COMPOSITION ROOF SHINGLES LAP SIDING - BODY 01 LAP SIDING - BODY 02 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 02 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 8'-0" OVERHEAD DOOR - TRIM 01 *ALL GARAGES TO MATCH MATERIALS AND COLORS, TYP. COMPOSITION ROOF SHINGLES LAP SIDING - BODY 02 OVERALL BUILDING HEIGHT 13'-1 1/4" 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 02 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 2 12 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 01 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 2 12 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 01 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 COMPOSITION ROOF SHINGLES LAP SIDING - BODY 02 2:12 BODY 01 BODY 02 BODY 03 1ST LEVEL 100'-0" T.O. CURB 100'-6" *ALL GARAGES TO MATCH MATERIALS AND COLORS, TYP. COMPOSITION ROOF SHINGLES LAP SIDING - BODY 02 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 LAP SIDING - BODY 01 OVERALL BUILDING HEIGHT 13'-1 1/4" 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 02 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 2 12 1ST LEVEL 100'-0" T.O. CURB 100'-6" LAP SIDING - BODY 01 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 2 12 1ST LEVEL 100'-0" T.O. CURB 100'-6" COMPOSITION ROOF SHINGLES LAP SIDING - BODY 01 ADHERED MASONRY - STONE, TYP. FASCIA BOARD - TRIM 01 LAP SIDING - BODY 02 2:12 BODY 01 BODY 02 BODY 03 TRIM 01 COLOR (MANUF.) COMMENTS STONE: CORONADO: PROLEDGE - OAKBROOK COMPOSITE WOOD: TREX - COASTAL BLUFF BODY 01: BM(AC-38): NORTH HAMPTON BEIGE BODY 02: BM(2126-40): SWEATSHIRT GRAY ACCENT 02: BM(2127-70): CASCADE WHITE ACCENT 01: CMG METALS: ROYAL BLUE TRIM 01: BM(2134-10): NIGHT HORIZON BODY 03: BM(CSP-90): COACHMAN'S CAPE 303.455.4437 5975 S. QUEBEC ST., STE. 250 CENTENNIAL, CO 80111 APARTMENT COLOR SCHEME 1 RIDGEWOOD HILLS - JUNE 03, 2020 STONE: CORONADO: PROLEDGE - HURON WOOD: TREX: SPICED RUM ACCENT 01: CMG METALS: VINTAGE BODY 01: BM(AC-38): NORTH HAMPTON BEIGE BODY 02: BM(AF-560): FLINT TRIM 01: BM(2134-10): NIGHT HORIZON BODY 03: BM(CSP-90): COACHMAN'S CAPE ACCENT 02: BM(2127-70): CASCADE WHITE 303.455.4437 5975 S. QUEBEC ST., STE. 250 CENTENNIAL, CO 80111 APARTMENT COLOR SCHEME 2 RIDGEWOOD HILLS -- JUNE 03, 2020 STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) CORONADO PROLEDGE - HURON COMPOSITE WOOD TREX - SPICED RUM * ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) LAP SIDING LAP SIDING VERTICAL SIDING EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE D ELEVATIONS 1/4" = 1'-0" A3.73 1 GARAGE D - FRONT ELEVATION 1/4" = 1'-0" 2 GARAGE D - RIGHT SIDE ELEVATION 1/4" = 1'-0" 3 GARAGE D - LEFT SIDE ELEVATION 1/4" = 1'-0" 4 GARAGE D - REAR ELEVATION TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) CORONADO PROLEDGE - HURON COMPOSITE WOOD TREX - SPICED RUM * ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) LAP SIDING LAP SIDING VERTICAL SIDING EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE C ELEVATIONS 1/4" = 1'-0" A3.72 1 GARAGE C - FRONT ELEVATION 1/4" = 1'-0" 2 GARAGE C - RIGHT SIDE ELEVATION 1/4" = 1'-0" 3 GARAGE C - LEFT SIDE ELEVATION 1/4" = 1'-0" 4 GARAGE C - REAR ELEVATION COMPOSITE WOOD SIDING 2:12 BODY 01 BODY 02 BODY 03 TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) CORONADO PROLEDGE - HURON COMPOSITE WOOD TREX - SPICED RUM * ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) LAP SIDING LAP SIDING VERTICAL SIDING EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE B ELEVATIONS 1/4" = 1'-0" A3.71 1 GARAGE B - FRONT ELEVATION 1/4" = 1'-0" 2 GARAGE B RIGHT SIDE ELEVATION 1/4" = 1'-0" 3 GARAGE B LEFT SIDE ELEVATION 1/4" = 1'-0" 4 GARAGE B REAR ELEVATION BODY 03 TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) CORONADO PROLEDGE - HURON COMPOSITE WOOD TREX - SPICED RUM * ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) LAP SIDING LAP SIDING VERTICAL SIDING EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE A ELEVATIONS 1/4" = 1'-0" A3.70 1 GARAGE A - FRONT ELEVATION 1/4" = 1'-0" 4 GARAGE A - REAR ELEVATION 1/4" = 1'-0" 3 GARAGE A - LEFT SIDE ELEVATION 1/4" = 1'-0" 2 GARAGE A - RIGHT SIDE ELEVATION SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER BUILDER'S SPECIFICATION, SHALL BE IN COMPLIANCE WITH SECTION 1106 BASED ON THE RAINFALL RATE AND CALCULATED AREA BEING DRAINED. WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS SHALL BE PROVIDED PER SECTION 1108. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • DRAFTSTOPPING SHALL BE PROVIDED IN ATTICS AND CONCEALED ROOF SPACES PER 2015 IBC SECTION 718.4.2. INSTALL IN LOCATIONS AS SHOWN IN PLAN; IN LINE WITH DWELLING UNIT SEPARATION WALLS, CORRIDORS, AND SUBDIVIDING THE ATTIC SPACE INTO AREAS NOT EXCEEDING 3,000 SQUARE FEET OR ABOVE EVERY TWO DWELLING UNITS, WHICHEVER IS SMALLER. OPENINGS IN DRAFTSTOPS SHALL BE PROTECTED BY SELF-CLOSING DOORS PER CODE. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE D ROOF PLAN 1/4" = 1'-0" A1.77 1 GARAGE D - ROOF PLAN CALCULATED AREA BEING DRAINED. WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS SHALL BE PROVIDED PER SECTION 1108. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • DRAFTSTOPPING SHALL BE PROVIDED IN ATTICS AND CONCEALED ROOF SPACES PER 2015 IBC SECTION 718.4.2. INSTALL IN LOCATIONS AS SHOWN IN PLAN; IN LINE WITH DWELLING UNIT SEPARATION WALLS, CORRIDORS, AND SUBDIVIDING THE ATTIC SPACE INTO AREAS NOT EXCEEDING 3,000 SQUARE FEET OR ABOVE EVERY TWO DWELLING UNITS, WHICHEVER IS SMALLER. OPENINGS IN DRAFTSTOPS SHALL BE PROTECTED BY SELF-CLOSING DOORS PER CODE. 1c 2c 3c 4c 5c E F Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE C ROOF PLAN 1/4" = 1'-0" A1.75 1 GARAGE C - ROOF PLAN 1 GARAGE C - 1ST LEVEL 1/4" = 1'-0" 2 GARAGE C - SLAB PLAN CALCULATED AREA BEING DRAINED. WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS SHALL BE PROVIDED PER SECTION 1108. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • DRAFTSTOPPING SHALL BE PROVIDED IN ATTICS AND CONCEALED ROOF SPACES PER 2015 IBC SECTION 718.4.2. INSTALL IN LOCATIONS AS SHOWN IN PLAN; IN LINE WITH DWELLING UNIT SEPARATION WALLS, CORRIDORS, AND SUBDIVIDING THE ATTIC SPACE INTO AREAS NOT EXCEEDING 3,000 SQUARE FEET OR ABOVE EVERY TWO DWELLING UNITS, WHICHEVER IS SMALLER. OPENINGS IN DRAFTSTOPS SHALL BE PROTECTED BY SELF-CLOSING DOORS PER CODE. C D 1b 2b 3b 4b 5b 6b Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE B ROOF PLAN 1/4" = 1'-0" A1.73 1 GARAGE B - ROOF PLAN REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE B PLANS 1/4" = 1'-0" A1.72 1 GARAGE B - 1ST LEVEL 1/4" = 1'-0" 2 GARAGE B - SLAB PLAN CALCULATED AREA BEING DRAINED. WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS SHALL BE PROVIDED PER SECTION 1108. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • DRAFTSTOPPING SHALL BE PROVIDED IN ATTICS AND CONCEALED ROOF SPACES PER 2015 IBC SECTION 718.4.2. INSTALL IN LOCATIONS AS SHOWN IN PLAN; IN LINE WITH DWELLING UNIT SEPARATION WALLS, CORRIDORS, AND SUBDIVIDING THE ATTIC SPACE INTO AREAS NOT EXCEEDING 3,000 SQUARE FEET OR ABOVE EVERY TWO DWELLING UNITS, WHICHEVER IS SMALLER. OPENINGS IN DRAFTSTOPS SHALL BE PROTECTED BY SELF-CLOSING DOORS PER CODE. 1a 2a 3a 4a 5a 6a A B Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE A ROOF PLAN A1.71 1/4" = 1'-0" 2 GARAGE A - ROOF PLAN JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION GARAGE A PLANS 1/4" = 1'-0" A1.70 1 GARAGE A - 1ST LEVEL 1/4" = 1'-0" 2 GARAGE A - SLAB PLAN TRIM 01, TYP. ALUMINUM STOREFRONT METAL TRELLIS - TRIM 01 OVERALL BUILDING HEIGHT 20'-10 3/4" EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION CLUBHOUSE ELEVATIONS 1/4" = 1'-0" A2.61 1 SOUTH ELEVATION (POOL ENTRY) 3 SOUTH WEST PERSPECTIVE 1/4" = 1'-0" 2 WEST ELEVATION ACCENT 01 2X12 FASCIA BOARD EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION CLUBHOUSE ELEVATIONS 1/4" = 1'-0" A2.60 1 NORTH ELEVATION (MAIN ENTRY) 1/4" = 1'-0" 2 EAST ELEVATION 3 NORTH EAST PERSPECTIVE TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) ROYAL BLUE (CMG METALS) CASCADE WHITE (BM 2127-70) CORONADO PROLEDGE - OAKBROOK COMPOSITE WOOD TREX - COASTAL BLUFF * ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) ARCHITECTURAL GRADE METAL PANEL LAP SIDING LAP SIDING VERTICAL SIDING STUCCO EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-48 ELEVATIONS A2.51 1/8" = 1'-0" 3 SOUTH ELEVATION 1/8" = 1'-0" 1 EAST ELEVATION 2 SOUTH - EAST - BUILDING PERSPECTIVE 40'-0" BODY 01 BODY 02 BODY 03 ACCENT 01 ACCENT 02 TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) ROYAL BLUE (CMG METALS) CASCADE WHITE (BM 2127-70) CORONADO PROLEDGE - OAKBROOK COMPOSITE WOOD TREX - COASTAL BLUFF * ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) ARCHITECTURAL GRADE METAL PANEL LAP SIDING LAP SIDING VERTICAL SIDING STUCCO EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-48 ELEVATIONS A2.50 1/8" = 1'-0" 3 NORTH ELEVATION 1/8" = 1'-0" 1 WEST ELEVATION 2 NORTH - WEST BUILDING PERSPECTIVE BED. Redundant Room LARGE 1 BED. 659 SF LARGE 1 BED. 1,332 SF LARGE 1 BED. Redundant Room LARGE 1 BED. 666 SF LARGE 1 BED. Redundant Room LARGE 1 BED. 1,332 SF LARGE 1 BED. 666 SF LARGE 1 1,068 SF BED. 3 BED 730 SF SMALL 2 BED. 1,004 SF LARGE 2 BED. N 27'-6" 7'-0" 27'-6" 68'-4" 4'-0" 4'-0" 216'-0 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-48 - THIRD LEVEL BUILDING PLAN A1.52 1/8" = 1'-0" 1 THIRD FLOOR 551 SF MEDIUM 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 1,068 SF BED. 3 BED 730 SF SMALL 2 BED. 1,003 SF LARGE 2 BED. N 1'-2" 1'-2" 1'-0" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 4'-1 3/4" 4'-6 1/2" 3'-2 1/2"1'-6" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-48 - SECOND LEVEL BUILDING PLAN A1.51 1/8" = 1'-0" 1 SECOND FLOOR 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 666 SF LARGE 1 BED. 655 SF LARGE 1 BED. 666 SF LARGE 1 BED. 551 SF MEDIUM 1 BED. 502 SF SMALL 1 BED. 676 SF LARGE 1 BED. 1,014 SF LARGE 2 BED. 666 SF LARGE 1 BED. 502 SF SMALL 1 BED. MECH H2O 220'-0 1/2" 7'-0" N 5'-10 1/2" 2'-5" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-48 - FIRST LEVEL BUILDING PLAN A1.50 1/8" = 1'-0" 1 FIRST FLOOR 3RD LEVEL 2 12 OVERALL BUILDING HEIGHT 40'-0" STANDING SEAM METAL ROOF VERTICAL SIDING - BODY 03, TYP. PAINTED WOOD CORBELS - TRIM 01 2X12 FASCIA BOARD - TRIM 01, TYP. METAL PANEL - ACCENT 01, TYP. COMPOSITE WOOD SCREEN STUCCO - ACCENT 02 METAL RAILING - TRIM 01, TYP. LAP SIDING - BODY 02 ADHERED MASONRY, TYP. VINYL WINDOW, TYP. 5/4 HARDBOARD TRIM - TRIM 01, TYP. 1X4 STUCCO TRIM - TRIM 01, TYP. UTILITY METERS, RE: CIVIL EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-42 ELEVATIONS 1/8" = 1'-0" A2.41 1 SOUTH ELEVATION 3 SOUTH - EAST BUILDING PERSPECTIVE 1/8" = 1'-0" 2 EAST ELEVATION 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL LAP SIDING - BODY 02 ADHERED MASONRY, TYP. VINYL WINDOW, TYP. METAL PANEL - ACCENT 01 METAL PARAPET CAP - TRIM 01 PAINTED WOOD CORBELS - TRIM 01, TYP. 5/4 HARDBOARD TRIM - TRIM 01 STANDING SEAM METAL ROOF VERTICAL SIDING - BODY 03 1X4 STUCCO TRIM - TRIM 01, TYP. OVERALL BUILDING HEIGHT 40'-0" EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-42 ELEVATIONS 1/8" = 1'-0" A2.40 1 NORTH ELEVATION 3 NORTH - WEST BUILDING PERSPECTIVE 1/8" = 1'-0" 2 WEST ELEVATION 1,000 SF LARGE 2 BED. 1,002 SF LARGE 2 BED. 989 SF LARGE 2 BED. 1,000 SF LARGE 2 BED. 216'-0 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" N D C B A 1'-2" 27'-6" 7'-0" 27'-6" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-42 - THIRD LEVEL BUILDING PLAN A1.42 1/8" = 1'-0" 1 THIRD FLOOR LARGE 1 BED. 666 SF LARGE 1 BED. 562 SF MEDIUM 1 BED. 473 SF LARGE STUDIO 376 SF STUDIO 1,788 SF SMALL 2 BED. Redundant Room 3 BED 375 SF END STUDIO 3'-10" 64'-4" 3'-10" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 220'-0 1/2" 666 SF LARGE 1 BED. N D C B A 1 1/2" 1'-2" 1'-2" 1'-2" 1'-2" Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-42 - SECOND LEVEL BUILDING PLAN A1.41 1/8" = 1'-0" 1 SECOND FLOOR 1,000 SF LARGE 2 BED. 477 SF LARGE STUDIO 1,001 SF LARGE 2 BED. 1,000 SF LARGE 2 BED. 1,001 SF LARGE 2 BED. 3'-10" 64'-4" 3'-10" 375 SF END STUDIO H20 224'-6 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" MECH N D C B A Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BUILDING A-42 - FIRST LEVEL BUILDING PLAN A1.40 1/8" = 1'-0" 1 FIRST FLOOR CAP - TRIM 01, TYP. 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL UTILITY METERS, RE: CIVIL METAL RAILINGS - TRIM 01, TYP. ARCHITECTURAL GRADE METAL PANEL - ACCENT 01 METAL RAILING - TRIM 01, TYP. LAP SIDING - BODY 01, TYP. ADHERED MASONRY, TYP. STUCCO - ACCENT 02 VINYL WINDOW, TYP. STANDING SEAM METAL ROOF COMPOSITE WOOD SCREEN 2X12 FASCIA BOARD - TRIM 01 1X4 STUCCO TRIM - TRIM 01, TYP. PAINTED WOOD CORBELS - TRIM 01 METAL PARAPET CAP - TRIM 01, TYP. OVERALL BUILDING HEIGHT 40'-0" 1ST LEVEL 100'-0" 2ND LEVEL 3RD LEVEL VERTICAL SIDING - BODY 03 COMPOSITE WOOD SCREEN ADHERED MASONRY, TYP. STUCCO - ACCENT 02 1X4 STUCCO TRIM - TRIM 01, TYP. ARCHITECTURAL GRADE METAL PANEL - ACCENT 01 METAL RAILING - TRIM 02, TYP. LAP SIDING - BODY 01 METAL PARAPET CAP - TRIM 01, TYP. WALL-MOUNTED HVAC UNIT, TYP. VINYL WINDOW, TYP. PAINTED WOOD CORBELS - TRIM 01, TYP. STANDING SEAM METAL ROOF 2X12 FASCIA BOARD - TRIM 01, TYP. PAINTED STEEL AWNING - TRIM 02 5/4 HARDBOARD TRIM - TRIM 01, TYP. ALUMINUM STOREFRONT OVERALL BUILDING HEIGHT 40'-0" 2 12 BODY 01 BODY 02 BODY 03 ACCENT 01 ACCENT 02 TRIM 01 COLOR (MANUF.) COMMENTS STONE EXTERIOR FINISH MATERIAL SCHEDULE NORTH HAMPTON BEIGE (BM AC-38) SWEATSHIRT GRAY (BM 2126-40) AGED COPPER (CMG METALS) CASCADE WHITE (BM 2127-70) CORONADO PROLEDGE - HURON COMPOSITE WOOD TREX - SPICED RUM * ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL. NIGHT HORIZON (BM 2134-10) COACHMAN'S CAPE (BM CSP-90) ARCHITECTURAL GRADE METAL PANEL LAP SIDING LAP SIDING VERTICAL SIDING STUCCO EXTERIOR BUILDING LIGHTS: LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND DARK SKY COMPLIANT. Sheet Sheet Name Checked By: Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BLDG A-24 ELEVATIONS A2.30 1/8" = 1'-0" 6 SOUTH - EAST ELEVATION 1/8" = 1'-0" 5 SOUTH-WEST ELEVATION 1/8" = 1'-0" 3 NORTH-EAST ELEVATION 1/8" = 1'-0" 4 NORTH-WEST ELEVATION 2 NORTH PERSPECTIVE 1 SOUTH PERSPECTIVE NOT FOR CONSTRUCTION BLDG A-24 THIRD LEVEL BUILDING PLAN A1.32 1/8" = 1'-0" 1 THIRD FLOOR DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BLDG A-24 SECOND LEVEL BUILDING PLAN A1.31 1/8" = 1'-0" 1 SECOND FLOOR Drawn By: Date: Ridgewood Hills Fifth Filing CW DA JUNE 03, 2020 PDP SUBMITTAL REV. COMMENT DATE NOT FOR CONSTRUCTION BLDG A-24 FIRST LEVEL BUILDING PLAN A1.30 1/8" = 1'-0" 1 FIRST FLOOR