HomeMy WebLinkAboutRIDGEWOOD HILLS FIFTH FILING - PDP190018 - SUBMITTAL DOCUMENTS - ROUND 4 - ARCHITECTURAL DETAILSW/D
W/D
REF. DW
REF.
DW
W/D
W/D
REF. DW
REF.
DW
DW REF.
W/D
DW
REF.
W/D
W/D
W/D
DW
REF. REF.
DW
1 2 3 4 5 6 7 8 9
502 SF
SMALL 1
BED.
898 SF
MEDIUM
2 BED.
377 SF
STUDIO
551 SF
MEDIUM
1 BED.
551 SF
MEDIUM
1 BED.
502 SF
SMALL 1
BED.
1,460 SF
SMALL 2
BED.
?
?
A
B
C
D
101'-8"
Redundant Room
SMALL 2
BED.
MECH.
H2O
62'-0"
MECH.
N
3'-11 7/8"
Sheet
Sheet Name
Checked By:
REF.
DW
REF.
DW
W/D
W/D
REF. DW
W/D
W/D
REF. DW
UP
DW REF.
W/D
DW
REF.
W/D
W/D
W/D
DW
REF.
DW
REF.
1 2 3 4 5 6 7 8 9
502 SF
SMALL 1
BED.
502 SF
SMALL 1
BED.
898 SF
MEDIUM
2 BED.
551 SF
MEDIUM
1 BED.
A
B
C
D
4'-0"
655 SF
LARGE 1
BED.
377 SF
STUDIO
1,460 SF
SMALL 2
BED.
Redundant Room
SMALL 2
BED.
6"
N
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
REF.
DW
REF.
DW
W/D
W/D
REF. DW
W/D
W/D
REF. DW
DW
REF.
W/D
DW
REF.
W/D
W/D
W/D
DW
REF.
DW
REF.
1 2 3 4 5 6 7 8 9
A
B
C
D
1,007 SF
SMALL 1
BED.
Redundant Room
SMALL 1
BED.
551 SF
MEDIUM
1 BED.
655 SF
LARGE 1
BED.
SMALL 2
BED.
SMALL 2
BED.
STUDIO
MEDIUM
2 BED.
62'-0"
101'-8"
N
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
3
12
ARCHITECTURAL GRADE
METAL PANEL - ACCENT 01
COMPOSITE
WOOD SCREEN
ADHERED
MASONRY, TYP.
STUCCO - ACCENT 02
VINYL
WINDOW, TYP.
LAP SIDING - BODY 01, TYP.
METAL RAILING -
TRIM 01, TYP.
LAP SIDING - BODY 02
METAL PARAPET CAP - TRIM 01, TYP.
1X4 STUCCO TRIM -
TRIM 01, TYP.
WALL-MOUNTED
HVAC UNIT, TYP.
5/4 HARDBOARD
TRIM - TRIM 01, TYP.
2
12
PAINTED STEEL AWNING - TRIM 02
ALUMINUM STOREFRONT
OVERALL BUILDING HEIGHT
40'-0"
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
3:12
ARCHITECTURAL
GRADE METAL
PANEL - ACCENT 01
METAL RAILING - TRIM 01, TYP.
LAP SIDING - BODY 01, TYP.
ADHERED
MASONRY, TYP.
STUCCO - ACCENT 02
VINYL
WINDOW, TYP.
STANDING SEAM
METAL ROOF
COMPOSITE WOOD SCREEN
2X12 FASCIA
BOARD - TRIM 01
UTILITY METERS, RE: CIVIL
1X4 STUCCO TRIM -
TRIM 01, TYP.
PAINTED WOOD
CORBELS - TRIM 01
OVERALL BUILDING HEIGHT
40'-0"
METAL PARAPET
W/D
REF.
DW
W/D
DW
W/D W/D REF.
DW
REF.
DW
REF.
W/D
DW
W/D REF.
W/D
REF.
DW
DW
REF. W/D
W/D
W/D
REF.
DW
REF. DW
W/D
REF.
DW
W/D
DW
REF.
DW
W/D REF.
DW
REF.
DW
REF.
W/D
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
375 SF
END
STUDIO
666 SF
LARGE 1
BED.
562 SF
MEDIUM
1 BED.
376 SF
STUDIO
999 SF
LARGE 2
BED.
666 SF
LARGE 1
BED.
1,001 SF
LARGE 2
BED.
1,000 SF
LARGE 2
BED.
W/D
REF.
DW
W/D
REF.
DW
DW
REF.
W/D
DW
REF. W/D
W/D
W/D W/D
DW
W/D REF.
DW
W/D REF.
REF.
DW
W/D
W/D
W/D
DW
REF.
DW
REF.
W/D
DW
REF.
DW
REF.
REF. DW
DW
REF.
W/D
DW
REF.
W/D
DW
REF.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
375 SF
END
STUDIO
1,000 SF
LARGE 2
BED.
989 SF
LARGE 2
BED.
1,002 SF
LARGE 2
BED.
1,000 SF
LARGE 2
BED.
1,000 SF
LARGE 2
BED.
666 SF
W/D
REF.
DW
W/D
REF.
DW
W/D
W/D W/D W/D W/D W/D
W/D
W/D W/D
W/D
W/D
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
375 SF
END
STUDIO
375 SF
END
STUDIO
727 SF
SMALL 2
BED.
1,001 SF
LARGE 2
BED.
998 SF
LARGE 2
BED.
1,000 SF
LARGE 2
BED.
1,061 SF
3 BED 666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
2
12
OVERALL BUILDING HEIGHT
40'-0"
LAP SIDING - BODY 02
VERTICAL SIDING -
BODY 03, TYP.
METAL PANEL - ACCENT 01, TYP.
COMPOSITE WOOD SCREEN
ADHERED
MASONRY,
TYP.
STUCCO - ACCENT 02
STANDING SEAM METAL ROOF
5/4 HARDBOARD
TRIM - TRIM 01, TYP.
LAP SIDING - BODY 01, TYP.
METAL RAILING - TRIM 01, TYP.
PAINTED WOOD CORBELS - TRIM 01
METAL PARAPET CAP - TRIM 01, TYP.
WALL-
MOUNTED
HVAC UNIT,
TYP.
VINYL
WINDOW, TYP.
1X4 STUCCO
TRIM - TRIM
01, TYP.
UTILITY METERS,
RE: CIVIL
BODY 01
BODY 02
BODY 03
ACCENT 01
ACCENT 02
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
AGED COPPER (CMG METALS)
CASCADE WHITE (BM 2127-70)
CORONADO PROLEDGE - HURON
COMPOSITE WOOD TREX - SPICED RUM
* ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS
OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
ARCHITECTURAL GRADE
METAL PANEL
LAP SIDING
LAP SIDING
VERTICAL SIDING
STUCCO
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
OVERALL BUILDING HEIGHT
39'-7"
LAP SIDING - BODY 02
VERTICAL SIDING -
BODY 03, TYP.
METAL PANEL - ACCENT 01 COMPOSITE WOOD SCREEN
ADHERED
MASONRY, TYP.
STUCCO - ACCENT 02
STANDING SEAM METAL ROOF
VINYL
WINDOW, TYP.
LAP SIDING - BODY 01, TYP.
METAL PARAPET
5/4 HARDBOARD CAP - TRIM 01
TRIM - TRIM 01, TYP.
METAL RAILING - TRIM 01, TYP.
PAINTED WOOD CORBELS - TRIM 01
1X4 STUCCO TRIM -
TRIM 01, TYP.
WALL-MOUNTED
HVAC UNIT, TYP.
2X12 FASCIA BOARD -
TRIM 01, TYP.
PAINTED STEEL
AWNING - TRIM 01, TYP.
UTILITY METERS,
RE: CIVIL
BODY 01
BODY 02
BODY 03
ACCENT 01
ACCENT 02
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
AGED COPPER (CMG METALS)
CASCADE WHITE (BM 2127-70)
CORONADO PROLEDGE - HURON
COMPOSITE WOOD TREX - SPICED RUM
* ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS
OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
ARCHITECTURAL GRADE
METAL PANEL
LAP SIDING
LAP SIDING
VERTICAL SIDING
STUCCO
1ST LEVEL
100'-0"
2ND LEVEL
W/D
W/D
DW REF.
REF.
DW
W/D
DW
REF.
W/D
W/D
DW REF.
REF.
DW
W/D
DW
W/D REF.
DW
REF.
W/D
DW
REF.
DW
REF.
W/D
W/D
DW
REF. W/D
DW
REF.
W/D
DW
REF.
W/D
DW
REF. W/D
DW
REF.
W/D
DW
W/D REF.
DW
REF.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
27'-6" 7'-0" 27'-6"
4'-0" 64'-4" 4'-0"
12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8
1/2"
551 SF
MEDIUM
1 BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
W/D
W/D
REF.
DW
DW
REF.
REF.
DW
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF. W/D
W/D W/D W/D
W/D
W/D W/D
W/D W/D
W/D
W/D
DW REF.
W/D
W/D
DW REF.
DW
REF.
W/D
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
27'-6" 7'-0" 27'-6"
68'-4" 4'-0"
4'-0" 216'-0 1/2"
12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8
1/2"
502 SF
SMALL 1
BED.
502 SF
SMALL 1
BED.
551 SF
MEDIUM
1 BED.
W/D
W/D
W/D
W/D W/D W/D
W/D
W/D W/D
W/D W/D
W/D
W/D
DW REF.
W/D
W/D
DW REF.
W/D REF.
DW
DW
REF.
REF.
DW
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
DW
REF.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A
B
C
D
502 SF
SMALL 1
BED.
502 SF
SMALL 1
BED.
551 SF
MEDIUM
1 BED.
551 SF
MEDIUM
1 BED.
1,332 SF
LARGE 1
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
VERTICAL SIDING - BODY 03
ADHERED MASONRY, TYP.
COMPOSITE
WOOD SCREEN
ADHERED
MASONRY, TYP.
STUCCO - ACCENT 02
1X4 STUCCO TRIM -
TRIM 01, TYP.
METAL PANEL -
ACCENT 01
METAL RAILING -
TRIM 02, TYP.
LAP SIDING -
BODY 01
METAL PARAPET
CAP - TRIM 01, TYP.
OVERALL BUILDING HEIGHT
40'-0"
WALL-MOUNTED
HVAC UNIT, TYP.
VINYL
WINDOW, TYP.
PAINTED WOOD
CORBELS - TRIM 01, TYP.
STANDING SEAM
METAL ROOF
2X12 FASCIA BOARD -
TRIM 01, TYP.
PAINTED STEEL
AWNING - TRIM 02
2X4 STUCCO TRIM -
TRIM 02
5/4 HARDBOARD
TRIM - TRIM 01, TYP.
2
12
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
VERTICAL
SIDING - BODY 03
ADHERED
MASONRY, TYP.
VINYL
WINDOW, TYP.
5/4 HARDBOARD
TRIM - TRIM 01
STANDING SEAM
METAL ROOF
1X4 STUCCO TRIM -
TRIM 01, TYP.
METAL PANEL - ACCENT 01
STUCCO - ACCENT 02
OVERALL BUILDING HEIGHT
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
METAL PANEL - ACCENT 01
COMPOSITE WOOD SCREEN
ADHERED
MASONRY, TYP.
STUCCO - ACCENT 02
VINYL
WINDOW, TYP.
LAP SIDING -
BODY 01, TYP.
METAL RAILING - TRIM 01, TYP.
LAP SIDING - BODY 02
METAL PARAPET CAP - TRIM 01, TYP.
METAL PANEL -
ACCENT 01
1X4 STUCCO TRIM -
TRIM 01, TYP.
WALL-MOUNTED
HVAC UNIT, TYP.
5/4 HARDBOARD
TRIM - TRIM 01, TYP.
PAINTED WOOD CORBELS - TRIM 01, TYP.
2X12 FASCIA BOARD - TRIM 01, TYP.
STANDING SEAM METAL ROOF
OVERALL BUILDING HEIGHT
40'-0"
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
VERTICAL
SIDING - BODY 03
METAL RAILING - TRIM 01, TYP.
LAP SIDING - BODY 01, TYP.
ADHERED
MASONRY, TYP.
STUCCO - ACCENT 02
VINYL
WINDOW, TYP.
STANDING SEAM
METAL ROOF
METAL PANEL - ACCENT 01
COMPOSITE WOOD SCREEN
2X12 FASCIA
BOARD - TRIM 01
UTILITY METERS, RE: CIVIL
5/4 HARDBOARD
TRIM - TRIM 01, TYP.
PAINTED WOOD
CORBELS - TRIM 01
OVERALL BUILDING HEIGHT
40'-0"
BODY 01
BODY 02
BODY 03
ACCENT 01
ACCENT 02
FITNESS
ENTRY
MECH
GAME
ROOM
KITCHEN
GATHERING
ROOM
MEN'S WOMEN'S
MECH JANITOR
STORAGE LEASING
OFFICE
BUSINESS
CENTER
47'-2"
20'-10 1/2" 12'-2" 11'-7 1/2"
POOL
EQUIP.
CORRIDOR
86'-3 1/2"
1'-6" 13'-2 1/2" 28'-0 1/2" 18'-0" 25'-6 1/2"
17'-3 1/2" 13'-2 1/2"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
CLUBHOUSE PLAN
A1.60
3/16" = 1'-0"
1
FIRST FLOOR
N
1ST LEVEL
100'-0"
OVERALL BUILDING HEIGHT
20'-10 3/4"
1
12
1
12
LAP SIDING - BODY 01
STANDING SEAM METAL ROOF
2X12 FASCIA BOARD - TRIM 01
PAINTED WOOD CORBELS - TRIM 01
ALUMINUM STOREFRONT
PAINTED STEEL
AWNING - TRIM 01, TYP.
LAP SIDING - BODY 02
ADHERED MASONRY, TYP. METAL PANEL - ACCENT 01, TYP.
1X4 STUCCO TRIM
BODY 01
BODY 02
BODY 03
ACCENT 01
ACCENT 02
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
AGED COPPER (CMG METALS)
CASCADE WHITE (BM 2127-70)
CORONADO PROLEDGE - HURON
COMPOSITE WOOD TREX - SPICED RUM
• ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR
EQUIVALENT, SUBJECT TO CITY APPROVAL.
• ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL,
AND DARK SKY COMPLIANT.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
ARCHITECTURAL GRADE
METAL PANEL
LAP SIDING
LAP SIDING
VERTICAL SIDING
STUCCO
1ST LEVEL
100'-0"
1
12
1
12
1
12
LAP SIDING - BODY 01
STANDING SEAM
METAL ROOF
LAP SIDING - BODY 02
ALUMINUM
STOREFRONT
METAL PANEL -
1ST LEVEL
100'-0"
OVERALL BUILDING HEIGHT
20'-10 3/4"
1:12
1:12
METAL PANEL - ACCENT 01
2X12 FASCIA BOARD - TRIM 01
ALUMINUM STOREFRONT
VERTICAL SIDING -
BODY 03
ADHERED
MASONRY,
TYP.
1X4 STUCCO TRIM
VINYL WINDOW, TYP.
LAP SIDING - BODY 01
STANDING SEAM METAL ROOF
PAINTED WOOD CORBELS - TRIM 01
BODY 01
BODY 02
BODY 03
ACCENT 01
ACCENT 02
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
AGED COPPER (CMG METALS)
CASCADE WHITE (BM 2127-70)
CORONADO PROLEDGE - HURON
COMPOSITE WOOD TREX - SPICED RUM
• ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS OF DESIGN, OR
EQUIVALENT, SUBJECT TO CITY APPROVAL.
• ALL BUILDING MOUNTED LIGHTING SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL,
AND DARK SKY COMPLIANT.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
ARCHITECTURAL GRADE
METAL PANEL
LAP SIDING
LAP SIDING
VERTICAL SIDING
STUCCO
1ST LEVEL
100'-0"
1
12
1:12
1
12
LAP SIDING -
BODY 01
VERTICAL SIDING -
BODY 03, TYP.
STANDING SEAM
METAL ROOF
2X12 FASCIA BOARD -
1a 2a 3a 4a 5a 6a
A
B
21'-8" 2'-0"
10'-10" 10'-4 1/2" 10'-4 1/2" 10'-4 1/2" 10'-10"
FRAME WALL
CENTERED ON
CONCRETE CURB
BELOW
3 1/2" 5'-6" 5'-0 1/2" 3 1/2" 5'-0 1/2" 5'-0 1/2" 3 1/2" 5'-0 1/2" 5'-0 1/2" 3 1/2" 5'-0 1/2" 5'-0 1/2" 3 1/2" 5'-0 1/2" 5'-2 1/2" 3 1/2"
31'-10 1/2" 20'-11"
52'-9 1/2"
2'-0"
TYPICAL TOP OF CURB
ELEVATION AT
PERIMETER AND
DIVIDING WALLS (6"
ABOVE TOP OF SLAB
ELEVATION AT OHD)
TYPICAL TOP OF
SLAB ELEVATION
AT BACK OF
GARAGE (2" BELOW
TOP OF CURB)
TYPICAL TOP OF SLAB ELEVATION AT
FRONT OF GARAGE/OHD (6" BELOW
TOP OF CURB).
REFER TO CIVIL GRADING FOR USGS
ELEVATIONS AND FINISH FLOOR
ELEVATIONS RELATIVE TO 100'-0" (FFE
= 100'-0", TYP.)
RE: CIVIL GRADING AND
STRUCTURAL FOUNDATION
PLANS FOR SLAB/CURB
STEPPING LOCATIONS AND
ELEVATIONS.
*THIS PLAN SHOWN WITHOUT
STEPS RELATIVE TO 100'-0".
STEPS AT FFE RESULT IN
STEPS AT TOP OF CURB,
WALLS, ROOF, ETC.
SLAB SLOPED TO DRAIN
TOWARDS OVERHEAD
DOORS. RE: SPOT
ELEVATIONS
(APPROXIMATELY
1/4"/1'-0" SLOPE), TYP.
1a 2a 3a 4a 5a 6a
A
B
52'-9 1/2"
1'-10 7/8" 21'-9 5/8"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
ROOF PLAN NOTES
• REFER TO GENERAL NOTES FOR ADDITIONAL
INFORMATION NOT SHOWN OR NOTED ON PLANS.
• ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM
FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS.
ALL SOFFITS ARE TO BE FLAT, U.N.O.
• ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER
THE SUPERVISION OF A COLORADO LICENSED
STRUCTURAL ENGINEER.
• ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR
OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES.
PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO
CONNECT ROOF AREAS.
• PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO
PROVIDE ATTIC VENTILATION AS REQUIRED PER 2015 IBC
SECTION 1203. RE: ROOF VENTING NOTES AND
CALCULATIONS.
• WATERPROOFING OF OPENINGS AT THE ROOF, AROUND
VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE
WATER TIGHT PER 2015 IPC SECTION 305.5.
• THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES
AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE
WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED
PER 2015 IPC SECTION 315. WHERE APPLICABLE,
PENETRATIONS IN FIRE-RATED ASSEMBLIES SHALL BE
SEALED IN ACCORDANCE WITH 2015 IBC SECTION 714.
• PIPES AND VENTS SHALL BE PAINTED TO MATCH
ADJACENT MATERIALS.
2015 INTERNATIONAL BUILDING CODE
• ROOF ASSEMBLIES PER 2015 IBC CHAPTER 1501:
ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER
PROTECTION PER 2015 IBC SECTION 1503 AND ROOF
COVERINGS PER SECTION 1507.
RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION.
• CRICKETS AND SADDLES SHALL BE INSTALLED AT THE
REQUIRED LOCATIONS PER 2015 IBC SECTION 1503.6.
CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL
OR OF THE SAME MATERIAL AS THE ROOF COVERING.
PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE
TO THE CRICKET OR SADDLE SLOPE.
• LOW SLOPE ROOFS - ASPHALT SHINGLES:
ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF
SLOPES OF 2:12 OR GREATER.
DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF
SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2015 IBC
SECTION 1507.2.8.
• AN ICE BARRIER SHALL BE INSTALLED AT EAVES,
EXTENDING FROM THE LOWEST EDGE TO A POINT AT
LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2015
IBC SECTION 1507.2.8.2 OR AS REQUIRED BY LOCAL
AMENDMENTS.
• METAL ROOF PANELS:
THE INSTALLATION, ATTACHMENT, AND UNDERLAYMENT
REQUIREMENTS OF METAL ROOF PANELS SHALL COMPLY
WITH 2015 IBC SECTION 1507.4.
• ROOF DRAINAGE PER 2015 IPC SECTION 1106:
SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER
BUILDER'S SPECIFICATION, SHALL BE IN COMPLIANCE WITH
SECTION 1106 BASED ON THE RAINFALL RATE AND
21'-2 1/2" 10'-4 1/2" 10'-4 1/2" 18'-1 1/2"
ACCESS AISLE
8'-0"
VAN PARKING STALL
8'-0"
C
D
1b 2b 3b 4b 5b 6b
10'-10" 10'-4 1/2" 10'-4 1/2" 10'-4 1/2" 18'-1 1/2"
10'-10" 10'-4 1/2" 10'-4 1/2" 10'-4 1/2" 18'-1 1/2"
60'-1"
21'-8"
RE: CIVIL GRADING AND
STRUCTURAL FOUNDATION
PLANS FOR SLAB/CURB
STEPPING LOCATIONS AND
ELEVATIONS.
*THIS PLAN SHOWN WITHOUT
STEPS RELATIVE TO 100'-0".
STEPS AT FFE RESULT IN
STEPS AT TOP OF CURB,
WALLS, ROOF, ETC.
TYPICAL TOP OF CURB
ELEVATION AT
PERIMETER AND
DIVIDING WALLS (6"
ABOVE TOP OF SLAB
ELEVATION AT OHD)
TYPICAL TOP OF
SLAB ELEVATION
AT BACK OF
GARAGE (2" BELOW
TOP OF CURB)
TYPICAL TOP OF SLAB ELEVATION
AT FRONT OF GARAGE/OHD (6"
BELOW TOP OF CURB).
REFER TO CIVIL GRADING FOR
USGS ELEVATIONS AND FINISH
FLOOR ELEVATIONS RELATIVE TO
100'-0" (FFE = 100'-0", TYP.)
SLAB SLOPED TO DRAIN
TOWARDS OVERHEAD
DOORS. RE: SPOT
ELEVATIONS
(APPROXIMATELY
1/4"/1'-0" SLOPE), TYP.
C
D
1b 2b 3b 4b 5b 6b
60'-1"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
ROOF PLAN NOTES
• REFER TO GENERAL NOTES FOR ADDITIONAL
INFORMATION NOT SHOWN OR NOTED ON PLANS.
• ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM
FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS.
ALL SOFFITS ARE TO BE FLAT, U.N.O.
• ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER
THE SUPERVISION OF A COLORADO LICENSED
STRUCTURAL ENGINEER.
• ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR
OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES.
PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO
CONNECT ROOF AREAS.
• PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO
PROVIDE ATTIC VENTILATION AS REQUIRED PER 2015 IBC
SECTION 1203. RE: ROOF VENTING NOTES AND
CALCULATIONS.
• WATERPROOFING OF OPENINGS AT THE ROOF, AROUND
VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE
WATER TIGHT PER 2015 IPC SECTION 305.5.
• THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES
AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE
WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED
PER 2015 IPC SECTION 315. WHERE APPLICABLE,
PENETRATIONS IN FIRE-RATED ASSEMBLIES SHALL BE
SEALED IN ACCORDANCE WITH 2015 IBC SECTION 714.
• PIPES AND VENTS SHALL BE PAINTED TO MATCH
ADJACENT MATERIALS.
2015 INTERNATIONAL BUILDING CODE
• ROOF ASSEMBLIES PER 2015 IBC CHAPTER 1501:
ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER
PROTECTION PER 2015 IBC SECTION 1503 AND ROOF
COVERINGS PER SECTION 1507.
RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION.
• CRICKETS AND SADDLES SHALL BE INSTALLED AT THE
REQUIRED LOCATIONS PER 2015 IBC SECTION 1503.6.
CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL
OR OF THE SAME MATERIAL AS THE ROOF COVERING.
PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE
TO THE CRICKET OR SADDLE SLOPE.
• LOW SLOPE ROOFS - ASPHALT SHINGLES:
ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF
SLOPES OF 2:12 OR GREATER.
DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF
SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2015 IBC
SECTION 1507.2.8.
• AN ICE BARRIER SHALL BE INSTALLED AT EAVES,
EXTENDING FROM THE LOWEST EDGE TO A POINT AT
LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2015
IBC SECTION 1507.2.8.2 OR AS REQUIRED BY LOCAL
AMENDMENTS.
• METAL ROOF PANELS:
THE INSTALLATION, ATTACHMENT, AND UNDERLAYMENT
REQUIREMENTS OF METAL ROOF PANELS SHALL COMPLY
WITH 2015 IBC SECTION 1507.4.
• ROOF DRAINAGE PER 2015 IPC SECTION 1106:
SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER
BUILDER'S SPECIFICATION, SHALL BE IN COMPLIANCE WITH
SECTION 1106 BASED ON THE RAINFALL RATE AND
21'-8"
1c 2c 3c 4c 5c
E
F
10'-10" 20'-9" 10'-10"
10'-10" 10'-4 1/2" 10'-4 1/2" 10'-10"
42'-5"
TYPICAL TOP OF CURB
ELEVATION AT
PERIMETER AND
DIVIDING WALLS (6"
ABOVE TOP OF SLAB
ELEVATION AT OHD)
TYPICAL TOP OF
SLAB ELEVATION
AT BACK OF
GARAGE (2" BELOW
TOP OF CURB)
TYPICAL TOP OF SLAB ELEVATION
AT FRONT OF GARAGE/OHD (6"
BELOW TOP OF CURB).
REFER TO CIVIL GRADING FOR
USGS ELEVATIONS AND FINISH
FLOOR ELEVATIONS RELATIVE TO
100'-0" (FFE = 100'-0", TYP.)
RE: CIVIL GRADING AND
STRUCTURAL FOUNDATION
PLANS FOR SLAB/CURB
STEPPING LOCATIONS AND
ELEVATIONS.
*THIS PLAN SHOWN WITHOUT
STEPS RELATIVE TO 100'-0".
STEPS AT FFE RESULT IN
STEPS AT TOP OF CURB,
WALLS, ROOF, ETC.
SLAB SLOPED TO DRAIN
TOWARDS OVERHEAD
DOORS. RE: SPOT
ELEVATIONS
(APPROXIMATELY
1/4"/1'-0" SLOPE), TYP.
1c 2c 3c 4c 5c
E
F
42'-5"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE C PLANS
1/4" = 1'-0" A1.74
ROOF PLAN NOTES
• REFER TO GENERAL NOTES FOR ADDITIONAL
INFORMATION NOT SHOWN OR NOTED ON PLANS.
• ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM
FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS.
ALL SOFFITS ARE TO BE FLAT, U.N.O.
• ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER
THE SUPERVISION OF A COLORADO LICENSED
STRUCTURAL ENGINEER.
• ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR
OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES.
PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO
CONNECT ROOF AREAS.
• PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO
PROVIDE ATTIC VENTILATION AS REQUIRED PER 2015 IBC
SECTION 1203. RE: ROOF VENTING NOTES AND
CALCULATIONS.
• WATERPROOFING OF OPENINGS AT THE ROOF, AROUND
VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE
WATER TIGHT PER 2015 IPC SECTION 305.5.
• THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES
AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE
WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED
PER 2015 IPC SECTION 315. WHERE APPLICABLE,
PENETRATIONS IN FIRE-RATED ASSEMBLIES SHALL BE
SEALED IN ACCORDANCE WITH 2015 IBC SECTION 714.
• PIPES AND VENTS SHALL BE PAINTED TO MATCH
ADJACENT MATERIALS.
2015 INTERNATIONAL BUILDING CODE
• ROOF ASSEMBLIES PER 2015 IBC CHAPTER 1501:
ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER
PROTECTION PER 2015 IBC SECTION 1503 AND ROOF
COVERINGS PER SECTION 1507.
RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION.
• CRICKETS AND SADDLES SHALL BE INSTALLED AT THE
REQUIRED LOCATIONS PER 2015 IBC SECTION 1503.6.
CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL
OR OF THE SAME MATERIAL AS THE ROOF COVERING.
PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE
TO THE CRICKET OR SADDLE SLOPE.
• LOW SLOPE ROOFS - ASPHALT SHINGLES:
ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF
SLOPES OF 2:12 OR GREATER.
DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF
SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2015 IBC
SECTION 1507.2.8.
• AN ICE BARRIER SHALL BE INSTALLED AT EAVES,
EXTENDING FROM THE LOWEST EDGE TO A POINT AT
LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2015
IBC SECTION 1507.2.8.2 OR AS REQUIRED BY LOCAL
AMENDMENTS.
• METAL ROOF PANELS:
THE INSTALLATION, ATTACHMENT, AND UNDERLAYMENT
REQUIREMENTS OF METAL ROOF PANELS SHALL COMPLY
WITH 2015 IBC SECTION 1507.4.
• ROOF DRAINAGE PER 2015 IPC SECTION 1106:
SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER
BUILDER'S SPECIFICATION, SHALL BE IN COMPLIANCE WITH
SECTION 1106 BASED ON THE RAINFALL RATE AND
G
H
1d 2d 3d 4d 5d
47'-8 1/2"
21'-8"
10'-10" 10'-4 1/2" 10'-4 1/2" 16'-1 1/2"
ACCESS AISLE
5'-0"
PARKING STALL
8'-0"
10'-10" 10'-4 1/2" 10'-4 1/2" 16'-1 1/2"
47'-8 1/2"
G
H
1d 2d 3d 4d 5d
47'-8 1/2"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE D PLANS
1/4" = 1'-0" A1.76
1
GARAGE D - 1ST LEVEL
1/4" = 1'-0"
2
GARAGE D - SLAB PLAN
G
H
1d 2d 3d 4d 5d
ROOF PLAN NOTES
• REFER TO GENERAL NOTES FOR ADDITIONAL
INFORMATION NOT SHOWN OR NOTED ON PLANS.
• ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM
FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS.
ALL SOFFITS ARE TO BE FLAT, U.N.O.
• ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER
THE SUPERVISION OF A COLORADO LICENSED
STRUCTURAL ENGINEER.
• ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR
OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES.
PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO
CONNECT ROOF AREAS.
• PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO
PROVIDE ATTIC VENTILATION AS REQUIRED PER 2015 IBC
SECTION 1203. RE: ROOF VENTING NOTES AND
CALCULATIONS.
• WATERPROOFING OF OPENINGS AT THE ROOF, AROUND
VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE
WATER TIGHT PER 2015 IPC SECTION 305.5.
• THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES
AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE
WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED
PER 2015 IPC SECTION 315. WHERE APPLICABLE,
PENETRATIONS IN FIRE-RATED ASSEMBLIES SHALL BE
SEALED IN ACCORDANCE WITH 2015 IBC SECTION 714.
• PIPES AND VENTS SHALL BE PAINTED TO MATCH
ADJACENT MATERIALS.
2015 INTERNATIONAL BUILDING CODE
• ROOF ASSEMBLIES PER 2015 IBC CHAPTER 1501:
ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER
PROTECTION PER 2015 IBC SECTION 1503 AND ROOF
COVERINGS PER SECTION 1507.
RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION.
• CRICKETS AND SADDLES SHALL BE INSTALLED AT THE
REQUIRED LOCATIONS PER 2015 IBC SECTION 1503.6.
CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL
OR OF THE SAME MATERIAL AS THE ROOF COVERING.
PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE
TO THE CRICKET OR SADDLE SLOPE.
• LOW SLOPE ROOFS - ASPHALT SHINGLES:
ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF
SLOPES OF 2:12 OR GREATER.
DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF
SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2015 IBC
SECTION 1507.2.8.
• AN ICE BARRIER SHALL BE INSTALLED AT EAVES,
EXTENDING FROM THE LOWEST EDGE TO A POINT AT
LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2015
IBC SECTION 1507.2.8.2 OR AS REQUIRED BY LOCAL
AMENDMENTS.
• METAL ROOF PANELS:
THE INSTALLATION, ATTACHMENT, AND UNDERLAYMENT
REQUIREMENTS OF METAL ROOF PANELS SHALL COMPLY
WITH 2015 IBC SECTION 1507.4.
• ROOF DRAINAGE PER 2015 IPC SECTION 1106:
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 02
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
OVERALL BUILDING HEIGHT
13'-1 1/4"
COMPOSITION
ROOF SHINGLES
2:12
8'-0" OVERHEAD
DOOR - TRIM 01
LAP SIDING -
BODY 01
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
COMPOSITION
ROOF SHINGLES
LAP SIDING -
BODY 01
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
LAP SIDING - TRIM 01
BODY 02
COMPOSITE
WOOD SIDING
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 01
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
2
12
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 02
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
2
12
BODY 01
BODY 02
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 02
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
COMPOSITION
ROOF SHINGLES
8'-0" OVERHEAD
DOOR - TRIM 01
*ALL GARAGES TO MATCH
MATERIALS AND COLORS, TYP.
LAP SIDING - BODY 01
OVERALL BUILDING HEIGHT
13'-1 1/4"
2:12
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 02
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
2
12 2
12
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 01
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
2
12
2
12
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
COMPOSITION
ROOF SHINGLES
LAP SIDING -
BODY 01
LAP SIDING - BODY 02
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 02
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
8'-0" OVERHEAD
DOOR - TRIM 01
*ALL GARAGES TO MATCH
MATERIALS AND COLORS, TYP.
COMPOSITION
ROOF SHINGLES
LAP SIDING - BODY 02
OVERALL BUILDING HEIGHT
13'-1 1/4"
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 02
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
2
12
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 01
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
2
12
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 01
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
COMPOSITION
ROOF SHINGLES
LAP SIDING - BODY 02
2:12
BODY 01
BODY 02
BODY 03
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
*ALL GARAGES TO MATCH
MATERIALS AND COLORS, TYP.
COMPOSITION
ROOF SHINGLES
LAP SIDING -
BODY 02
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
LAP SIDING - BODY 01
OVERALL BUILDING HEIGHT
13'-1 1/4"
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 02
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
2
12
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
LAP SIDING -
BODY 01
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
2
12
1ST LEVEL
100'-0"
T.O. CURB
100'-6"
COMPOSITION
ROOF SHINGLES
LAP SIDING -
BODY 01
ADHERED MASONRY -
STONE, TYP.
FASCIA BOARD -
TRIM 01
LAP SIDING - BODY 02
2:12
BODY 01
BODY 02
BODY 03
TRIM 01
COLOR (MANUF.) COMMENTS
STONE: CORONADO: PROLEDGE - OAKBROOK
COMPOSITE WOOD: TREX - COASTAL BLUFF
BODY 01: BM(AC-38): NORTH HAMPTON BEIGE
BODY 02: BM(2126-40): SWEATSHIRT GRAY
ACCENT 02: BM(2127-70): CASCADE WHITE
ACCENT 01: CMG METALS: ROYAL BLUE
TRIM 01: BM(2134-10): NIGHT HORIZON
BODY 03: BM(CSP-90): COACHMAN'S CAPE
303.455.4437
5975 S. QUEBEC ST., STE. 250
CENTENNIAL, CO 80111
APARTMENT COLOR
SCHEME 1
RIDGEWOOD HILLS
-
JUNE 03, 2020
STONE: CORONADO: PROLEDGE - HURON
WOOD: TREX: SPICED RUM
ACCENT 01: CMG METALS: VINTAGE
BODY 01: BM(AC-38): NORTH HAMPTON BEIGE BODY 02: BM(AF-560): FLINT
TRIM 01: BM(2134-10): NIGHT HORIZON
BODY 03: BM(CSP-90): COACHMAN'S CAPE
ACCENT 02: BM(2127-70): CASCADE WHITE
303.455.4437
5975 S. QUEBEC ST., STE. 250
CENTENNIAL, CO 80111
APARTMENT COLOR
SCHEME 2
RIDGEWOOD HILLS
--
JUNE 03, 2020
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
CORONADO PROLEDGE - HURON
COMPOSITE WOOD TREX - SPICED RUM
* ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS
OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
LAP SIDING
LAP SIDING
VERTICAL SIDING
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING
SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND
DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE D
ELEVATIONS
1/4" = 1'-0" A3.73
1
GARAGE D - FRONT ELEVATION
1/4" = 1'-0"
2
GARAGE D - RIGHT SIDE ELEVATION
1/4" = 1'-0"
3
GARAGE D - LEFT SIDE ELEVATION
1/4" = 1'-0"
4
GARAGE D - REAR ELEVATION
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
CORONADO PROLEDGE - HURON
COMPOSITE WOOD TREX - SPICED RUM
* ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS
OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
LAP SIDING
LAP SIDING
VERTICAL SIDING
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING
SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND
DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE C
ELEVATIONS
1/4" = 1'-0" A3.72
1
GARAGE C - FRONT ELEVATION
1/4" = 1'-0"
2
GARAGE C - RIGHT SIDE ELEVATION
1/4" = 1'-0"
3
GARAGE C - LEFT SIDE ELEVATION
1/4" = 1'-0"
4
GARAGE C - REAR ELEVATION
COMPOSITE
WOOD SIDING
2:12
BODY 01
BODY 02
BODY 03
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
CORONADO PROLEDGE - HURON
COMPOSITE WOOD TREX - SPICED RUM
* ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS
OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
LAP SIDING
LAP SIDING
VERTICAL SIDING
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING
SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND
DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE B
ELEVATIONS
1/4" = 1'-0" A3.71
1
GARAGE B - FRONT ELEVATION
1/4" = 1'-0"
2
GARAGE B RIGHT SIDE ELEVATION
1/4" = 1'-0"
3
GARAGE B LEFT SIDE ELEVATION
1/4" = 1'-0"
4
GARAGE B REAR ELEVATION
BODY 03
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
CORONADO PROLEDGE - HURON
COMPOSITE WOOD TREX - SPICED RUM
* ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS
OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
LAP SIDING
LAP SIDING
VERTICAL SIDING
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING
SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND
DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE A
ELEVATIONS
1/4" = 1'-0" A3.70
1
GARAGE A - FRONT ELEVATION
1/4" = 1'-0"
4
GARAGE A - REAR ELEVATION
1/4" = 1'-0"
3
GARAGE A - LEFT SIDE ELEVATION
1/4" = 1'-0"
2
GARAGE A - RIGHT SIDE ELEVATION
SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER
BUILDER'S SPECIFICATION, SHALL BE IN COMPLIANCE WITH
SECTION 1106 BASED ON THE RAINFALL RATE AND
CALCULATED AREA BEING DRAINED.
WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS
SHALL BE PROVIDED PER SECTION 1108.
• SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED
FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE
ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0"
AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS
REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO
THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS
FOR DETAILS AND LOCATIONS.
• DRAFTSTOPPING SHALL BE PROVIDED IN ATTICS AND
CONCEALED ROOF SPACES PER 2015 IBC SECTION 718.4.2.
INSTALL IN LOCATIONS AS SHOWN IN PLAN; IN LINE WITH
DWELLING UNIT SEPARATION WALLS, CORRIDORS, AND
SUBDIVIDING THE ATTIC SPACE INTO AREAS NOT
EXCEEDING 3,000 SQUARE FEET OR ABOVE EVERY TWO
DWELLING UNITS, WHICHEVER IS SMALLER. OPENINGS IN
DRAFTSTOPS SHALL BE PROTECTED BY SELF-CLOSING
DOORS PER CODE.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE D ROOF
PLAN
1/4" = 1'-0" A1.77
1
GARAGE D - ROOF PLAN
CALCULATED AREA BEING DRAINED.
WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS
SHALL BE PROVIDED PER SECTION 1108.
• SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED
FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE
ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0"
AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS
REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO
THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS
FOR DETAILS AND LOCATIONS.
• DRAFTSTOPPING SHALL BE PROVIDED IN ATTICS AND
CONCEALED ROOF SPACES PER 2015 IBC SECTION 718.4.2.
INSTALL IN LOCATIONS AS SHOWN IN PLAN; IN LINE WITH
DWELLING UNIT SEPARATION WALLS, CORRIDORS, AND
SUBDIVIDING THE ATTIC SPACE INTO AREAS NOT
EXCEEDING 3,000 SQUARE FEET OR ABOVE EVERY TWO
DWELLING UNITS, WHICHEVER IS SMALLER. OPENINGS IN
DRAFTSTOPS SHALL BE PROTECTED BY SELF-CLOSING
DOORS PER CODE.
1c 2c 3c 4c 5c
E
F
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE C ROOF
PLAN
1/4" = 1'-0" A1.75
1
GARAGE C - ROOF PLAN
1
GARAGE C - 1ST LEVEL
1/4" = 1'-0"
2
GARAGE C - SLAB PLAN
CALCULATED AREA BEING DRAINED.
WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS
SHALL BE PROVIDED PER SECTION 1108.
• SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED
FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE
ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0"
AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS
REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO
THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS
FOR DETAILS AND LOCATIONS.
• DRAFTSTOPPING SHALL BE PROVIDED IN ATTICS AND
CONCEALED ROOF SPACES PER 2015 IBC SECTION 718.4.2.
INSTALL IN LOCATIONS AS SHOWN IN PLAN; IN LINE WITH
DWELLING UNIT SEPARATION WALLS, CORRIDORS, AND
SUBDIVIDING THE ATTIC SPACE INTO AREAS NOT
EXCEEDING 3,000 SQUARE FEET OR ABOVE EVERY TWO
DWELLING UNITS, WHICHEVER IS SMALLER. OPENINGS IN
DRAFTSTOPS SHALL BE PROTECTED BY SELF-CLOSING
DOORS PER CODE.
C
D
1b 2b 3b 4b 5b 6b
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE B ROOF
PLAN
1/4" = 1'-0" A1.73
1
GARAGE B - ROOF PLAN
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE B PLANS
1/4" = 1'-0" A1.72
1
GARAGE B - 1ST LEVEL
1/4" = 1'-0"
2
GARAGE B - SLAB PLAN
CALCULATED AREA BEING DRAINED.
WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS
SHALL BE PROVIDED PER SECTION 1108.
• SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED
FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE
ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0"
AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS
REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO
THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS
FOR DETAILS AND LOCATIONS.
• DRAFTSTOPPING SHALL BE PROVIDED IN ATTICS AND
CONCEALED ROOF SPACES PER 2015 IBC SECTION 718.4.2.
INSTALL IN LOCATIONS AS SHOWN IN PLAN; IN LINE WITH
DWELLING UNIT SEPARATION WALLS, CORRIDORS, AND
SUBDIVIDING THE ATTIC SPACE INTO AREAS NOT
EXCEEDING 3,000 SQUARE FEET OR ABOVE EVERY TWO
DWELLING UNITS, WHICHEVER IS SMALLER. OPENINGS IN
DRAFTSTOPS SHALL BE PROTECTED BY SELF-CLOSING
DOORS PER CODE.
1a 2a 3a 4a 5a 6a
A
B
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE A ROOF
PLAN
A1.71
1/4" = 1'-0"
2
GARAGE A - ROOF PLAN
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
GARAGE A PLANS
1/4" = 1'-0" A1.70
1
GARAGE A - 1ST LEVEL
1/4" = 1'-0"
2
GARAGE A - SLAB PLAN
TRIM 01, TYP.
ALUMINUM
STOREFRONT
METAL TRELLIS -
TRIM 01
OVERALL BUILDING HEIGHT
20'-10 3/4"
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED
LIGHTING SHALL BE FULLY SHIELDED, DOWN
DIRECTIONAL, AND DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
CLUBHOUSE
ELEVATIONS
1/4" = 1'-0" A2.61
1
SOUTH ELEVATION (POOL ENTRY)
3
SOUTH WEST PERSPECTIVE
1/4" = 1'-0"
2
WEST ELEVATION
ACCENT 01
2X12 FASCIA
BOARD
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED
LIGHTING SHALL BE FULLY SHIELDED, DOWN
DIRECTIONAL, AND DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
CLUBHOUSE
ELEVATIONS
1/4" = 1'-0" A2.60
1
NORTH ELEVATION (MAIN ENTRY)
1/4" = 1'-0"
2
EAST ELEVATION
3
NORTH EAST PERSPECTIVE
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
ROYAL BLUE (CMG METALS)
CASCADE WHITE (BM 2127-70)
CORONADO PROLEDGE - OAKBROOK
COMPOSITE WOOD TREX - COASTAL BLUFF
* ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS
OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
ARCHITECTURAL GRADE
METAL PANEL
LAP SIDING
LAP SIDING
VERTICAL SIDING
STUCCO
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING
SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND
DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-48
ELEVATIONS
A2.51
1/8" = 1'-0"
3
SOUTH ELEVATION
1/8" = 1'-0"
1
EAST ELEVATION
2
SOUTH - EAST - BUILDING PERSPECTIVE
40'-0"
BODY 01
BODY 02
BODY 03
ACCENT 01
ACCENT 02
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
ROYAL BLUE (CMG METALS)
CASCADE WHITE (BM 2127-70)
CORONADO PROLEDGE - OAKBROOK
COMPOSITE WOOD TREX - COASTAL BLUFF
* ALL MATERIALS AND COLORS SHOWN ARE PROPOSED BASIS
OF DESIGN, OR EQUIVALENT, SUBJECT TO CITY APPROVAL.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
ARCHITECTURAL GRADE
METAL PANEL
LAP SIDING
LAP SIDING
VERTICAL SIDING
STUCCO
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING
SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND
DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-48
ELEVATIONS
A2.50
1/8" = 1'-0"
3
NORTH ELEVATION
1/8" = 1'-0"
1
WEST ELEVATION
2
NORTH - WEST BUILDING PERSPECTIVE
BED.
Redundant Room
LARGE 1
BED.
659 SF
LARGE 1
BED.
1,332 SF
LARGE 1
BED.
Redundant Room
LARGE 1
BED.
666 SF
LARGE 1
BED.
Redundant Room
LARGE 1
BED.
1,332 SF
LARGE 1
BED.
666 SF
LARGE 1
1,068 SF BED.
3 BED
730 SF
SMALL 2
BED.
1,004 SF
LARGE 2
BED.
N
27'-6" 7'-0" 27'-6"
68'-4" 4'-0"
4'-0" 216'-0 1/2"
12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8
1/2"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-48 -
THIRD LEVEL
BUILDING PLAN
A1.52
1/8" = 1'-0"
1
THIRD FLOOR
551 SF
MEDIUM
1 BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
1,068 SF BED.
3 BED
730 SF
SMALL 2
BED.
1,003 SF
LARGE 2
BED.
N
1'-2"
1'-2"
1'-0"
1'-2"
1'-2"
1'-2" 1'-2"
1'-2"
1'-2"
1'-2"
4'-1 3/4"
4'-6 1/2"
3'-2 1/2"1'-6"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-48 -
SECOND LEVEL
BUILDING PLAN
A1.51
1/8" = 1'-0"
1
SECOND FLOOR
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
655 SF
LARGE 1
BED.
666 SF
LARGE 1
BED.
551 SF
MEDIUM
1 BED.
502 SF
SMALL 1
BED.
676 SF
LARGE 1
BED.
1,014 SF
LARGE 2
BED.
666 SF
LARGE 1
BED.
502 SF
SMALL 1
BED.
MECH
H2O
220'-0 1/2" 7'-0"
N
5'-10 1/2"
2'-5"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-48 -
FIRST LEVEL
BUILDING PLAN
A1.50
1/8" = 1'-0"
1
FIRST FLOOR
3RD LEVEL
2
12
OVERALL BUILDING HEIGHT
40'-0"
STANDING SEAM METAL ROOF
VERTICAL SIDING - BODY 03, TYP.
PAINTED WOOD CORBELS - TRIM 01
2X12 FASCIA BOARD - TRIM 01, TYP.
METAL PANEL - ACCENT 01, TYP.
COMPOSITE WOOD SCREEN
STUCCO - ACCENT 02
METAL RAILING - TRIM 01, TYP.
LAP SIDING -
BODY 02
ADHERED
MASONRY, TYP.
VINYL
WINDOW, TYP.
5/4 HARDBOARD
TRIM - TRIM 01, TYP.
1X4 STUCCO TRIM -
TRIM 01, TYP.
UTILITY METERS,
RE: CIVIL
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING
SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND
DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-42
ELEVATIONS
1/8" = 1'-0" A2.41
1
SOUTH ELEVATION
3
SOUTH - EAST BUILDING PERSPECTIVE
1/8" = 1'-0"
2
EAST ELEVATION
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
LAP SIDING -
BODY 02
ADHERED
MASONRY, TYP.
VINYL
WINDOW, TYP.
METAL PANEL - ACCENT 01
METAL PARAPET
CAP - TRIM 01
PAINTED WOOD
CORBELS - TRIM 01, TYP.
5/4 HARDBOARD
TRIM - TRIM 01
STANDING SEAM METAL ROOF
VERTICAL SIDING -
BODY 03
1X4 STUCCO TRIM -
TRIM 01, TYP.
OVERALL BUILDING HEIGHT
40'-0"
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING
SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND
DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-42
ELEVATIONS
1/8" = 1'-0" A2.40
1
NORTH ELEVATION
3
NORTH - WEST BUILDING PERSPECTIVE
1/8" = 1'-0"
2
WEST ELEVATION
1,000 SF
LARGE 2
BED.
1,002 SF
LARGE 2
BED.
989 SF
LARGE 2
BED.
1,000 SF
LARGE 2
BED.
216'-0 1/2"
12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8
1/2"
N
D
C
B
A
1'-2" 27'-6" 7'-0" 27'-6" 1'-2"
1'-2"
1'-2"
1'-2"
1'-2"
1'-2" 1'-2"
1'-2"
1'-2"
1'-2" 1'-2"
1'-2"
1'-2"
1'-2"
1'-2" 1'-2" 1'-2"
1'-2" 1'-2"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-42 -
THIRD LEVEL
BUILDING PLAN
A1.42
1/8" = 1'-0"
1
THIRD FLOOR
LARGE 1
BED.
666 SF
LARGE 1
BED.
562 SF
MEDIUM
1 BED.
473 SF
LARGE
STUDIO
376 SF
STUDIO
1,788 SF
SMALL 2
BED.
Redundant Room
3 BED
375 SF
END
STUDIO
3'-10" 64'-4" 3'-10"
12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8
1/2"
220'-0 1/2"
666 SF
LARGE 1
BED.
N
D
C
B
A
1 1/2"
1'-2"
1'-2"
1'-2"
1'-2"
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-42 -
SECOND LEVEL
BUILDING PLAN
A1.41
1/8" = 1'-0"
1
SECOND FLOOR
1,000 SF
LARGE 2
BED.
477 SF
LARGE
STUDIO
1,001 SF
LARGE 2
BED.
1,000 SF
LARGE 2
BED.
1,001 SF
LARGE 2
BED.
3'-10" 64'-4" 3'-10"
375 SF
END
STUDIO
H20
224'-6 1/2"
12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8 1/2" 12'-8
1/2"
MECH
N
D
C
B
A
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BUILDING A-42 -
FIRST LEVEL
BUILDING PLAN
A1.40
1/8" = 1'-0"
1
FIRST FLOOR
CAP - TRIM 01, TYP.
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
UTILITY METERS, RE: CIVIL
METAL RAILINGS - TRIM 01, TYP.
ARCHITECTURAL
GRADE METAL
PANEL - ACCENT 01
METAL RAILING - TRIM 01, TYP.
LAP SIDING - BODY 01, TYP.
ADHERED
MASONRY, TYP.
STUCCO - ACCENT 02
VINYL
WINDOW, TYP.
STANDING SEAM
METAL ROOF
COMPOSITE WOOD SCREEN
2X12 FASCIA
BOARD - TRIM 01
1X4 STUCCO TRIM -
TRIM 01, TYP.
PAINTED WOOD
CORBELS - TRIM 01
METAL PARAPET
CAP - TRIM 01, TYP.
OVERALL BUILDING HEIGHT
40'-0"
1ST LEVEL
100'-0"
2ND LEVEL
3RD LEVEL
VERTICAL
SIDING - BODY 03
COMPOSITE
WOOD SCREEN
ADHERED
MASONRY, TYP.
STUCCO - ACCENT 02
1X4 STUCCO TRIM -
TRIM 01, TYP.
ARCHITECTURAL GRADE
METAL PANEL - ACCENT 01 METAL RAILING -
TRIM 02, TYP.
LAP SIDING - BODY 01
METAL PARAPET
CAP - TRIM 01, TYP.
WALL-MOUNTED
HVAC UNIT, TYP.
VINYL
WINDOW, TYP.
PAINTED WOOD
CORBELS - TRIM
01, TYP.
STANDING SEAM
METAL ROOF
2X12 FASCIA
BOARD -
TRIM 01, TYP.
PAINTED STEEL AWNING - TRIM 02
5/4 HARDBOARD
TRIM - TRIM 01, TYP.
ALUMINUM STOREFRONT
OVERALL BUILDING HEIGHT
40'-0"
2
12
BODY 01
BODY 02
BODY 03
ACCENT 01
ACCENT 02
TRIM 01
COLOR (MANUF.) COMMENTS
STONE
EXTERIOR FINISH MATERIAL SCHEDULE
NORTH HAMPTON BEIGE (BM AC-38)
SWEATSHIRT GRAY (BM 2126-40)
AGED COPPER (CMG METALS)
CASCADE WHITE (BM 2127-70)
CORONADO PROLEDGE - HURON
COMPOSITE WOOD TREX - SPICED RUM
* ALL MATERIALS AND COLORS
SHOWN ARE PROPOSED BASIS
OF DESIGN, OR EQUIVALENT,
SUBJECT TO CITY APPROVAL.
NIGHT HORIZON (BM 2134-10)
COACHMAN'S CAPE (BM CSP-90)
ARCHITECTURAL GRADE
METAL PANEL
LAP SIDING
LAP SIDING
VERTICAL SIDING
STUCCO
EXTERIOR BUILDING LIGHTS:
LIGHTS, ONCE SPECIFIED, WILL COMPLY WITH ALL
REQUIREMENTS. ALL BUILDING MOUNTED LIGHTING
SHALL BE FULLY SHIELDED, DOWN DIRECTIONAL, AND
DARK SKY COMPLIANT.
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BLDG A-24
ELEVATIONS
A2.30
1/8" = 1'-0"
6
SOUTH - EAST ELEVATION
1/8" = 1'-0"
5
SOUTH-WEST ELEVATION
1/8" = 1'-0"
3
NORTH-EAST ELEVATION
1/8" = 1'-0"
4
NORTH-WEST ELEVATION
2
NORTH PERSPECTIVE
1
SOUTH PERSPECTIVE
NOT FOR
CONSTRUCTION
BLDG A-24 THIRD
LEVEL BUILDING
PLAN
A1.32
1/8" = 1'-0"
1
THIRD FLOOR
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BLDG A-24
SECOND LEVEL
BUILDING PLAN
A1.31
1/8" = 1'-0"
1
SECOND FLOOR
Drawn By:
Date:
Ridgewood Hills Fifth Filing
CW
DA
JUNE 03, 2020
PDP SUBMITTAL
REV. COMMENT DATE
NOT FOR
CONSTRUCTION
BLDG A-24 FIRST
LEVEL BUILDING
PLAN
A1.30
1/8" = 1'-0"
1
FIRST FLOOR