Loading...
HomeMy WebLinkAboutVOA SENIOR RESIDENCES - FDP200015 - SUBMITTAL DOCUMENTS - ROUND 3 - ELEVATIONSLEVEL 1 100' - 0" LEVEL 2 111' - 6" LEVEL 3 122' - 4" T/ ROOF 139' - 10" PROPERTY LINE PROPERTY LINE 40'-10" F.S.D. 266'-8" 53'-11" F.S.D. 26.03 5.21 4.03 6.32 4.01 7.08 6.31 4.05 8.03 4.06 8.05 4.04 6.28 6.30 7.33 7.18 6.31 5.06 23.01 6.32 6.30 23.01 4.02 4.01 8.02 5.21 4.03 4.07 8.05 6.30 5.06 6.29 39'-10" 11'-6" 10'-10" 17'-6" 5.21 LEVEL 1 100' - 0" LEVEL 2 111' - 6" LEVEL 3 122' - 4" T/ ROOF 139' - 10" PROPERTY LINE 127'-1" F.S.D. 130'-8" 28'-4" PROPERTY LINE 8.02 8.03 4.03 LEVEL 1 100' - 0" LEVEL 2 111' - 6" LEVEL 3 122' - 4" T/ ROOF 139' - 10" PROPERTY LINE PROPERTY LINE 53'-11" F.S.D. 266'-8" 40'-10" F.S.D. 5.21 4.01 4.07 5.21 7.08 4.03 8.03 4.05 6.32 6.28 6.29 6.31 6.30 7.33 23.01 23.03 7.18 8.11 8.02 5.21 10.02 4.02 4.01 6.30 5.06 26.03 8.06 14.02 6.30 23.01 6.19 6.19 4.06 4.04 39'-10" 11'-6" 10'-10" 17'-6" LEVEL 1 100' - 0" LEVEL 2 111' - 6" LEVEL 3 122' - 4" T/ ROOF 139' - 10" PROPERTY LINE 41'-6" F.S.D. 58'-0" 4.03 4.05 8.03 4.01 FACP 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.1 0.1 0.1 0.2 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.6 0.6 0.6 0.4 0.3 0.2 0.6 1.0 0.9 0.5 0.3 0.8 1.3 1.1 0.9 0.5 0.6 0.4 0.2 0.1 0.1 0.0 SINGLE OR DOUBLE HEAD LUMINAIRE GROUNDING STUD WITH #8 CU GROUNDING WIRE TO REBAR 3 FIXTURE TYPE SE1 NO SCALE 8'-0" 2'-6" 24" #3 TIES 3" FROM TOP TOP OF FINISH GRADE. CONDUIT RISER, QUANTITY AS REQ'D. #3 HORIZ. BARS @ 12" O.C. 8#7, or 6#8 VERT BARS 1 #10 STRANDED TO LIGHTING FIXTURE 4" X 8" HANDHOLE IN LINE FUSE HOLDER 17'-6" 2 SE5 PEDESTRIAN POLE BASE DETAIL NO SCALE GROUNDING STUD WITH #8 CU GROUNDING WIRE TO REBAR 96" 4" 24" POLE SHAFT ANCHOR BOLT COVER 1 #10 STRANDED TO LIGHTING FIXTURE 4" X 8" HANDHOLE IN LINE FUSE HOLDER TOP OF FINISH GRADE. #3 TIES 3" FROM TOP CONDUIT RISER, QUANTITY AS REQ'D. #3 HORIZ. BARS @ 12" O.C. 8#7, or 6#8 VERT BARS BASE DEPTH SHALL BE FIELD VERIFIED WITH STRUCTURAL/CIVIL ENGINEER BASE ON ONSITE SOIL CONDITIONS AND FIXTURE ASSEMBLY EPA RATING. 11'-8" 4 FIXTURE TYPE SE2 NO SCALE 5 FIXTURE TYPE SE3 NO SCALE 6 *Site wall shown transparent for clarity 5 FDP 2 2020/10/14 ORIGINAL SIZE 24X36 ISSUED No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE 1 PDP 2019/2/27 2 PDP 2 2019/4/3 3 P & Z REVISIONS 2019/4/29 4 FDP 2020/8/5 5 FDP 2 2020/10/14 6 MYLARS 2020/11/17 5 FDP 2 2020/10/14 ORIGINAL SIZE 24X36 ISSUED No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE 1 PDP 2019/2/27 2 PDP 2 2019/4/3 3 P & Z REVISIONS 2019/4/29 4 FDP 2020/8/5 5 FDP 2 2020/10/14 6 MYLARS 2020/11/17 FD 4 12 5 12 3'-6" WIDE HM DOOR (4) 4 YARD TRASH AND RECYCLING DUMPSTERS SHOWN (2 EACH) OVERHEAD EXTERIOR DOOR FLOOR DRAIN 4'-11" 19'-4 1/2" 11'-7" 5'-4 1/2" TRASH CHUTE ABOVE RECYCLING CHUTE ABOVE TRASH RECYCLING JAN. 123 DUMPSTER ROOM 122 EAST SHAFT 148 EAST HALL 121 EXTERIOR CONCRETE WALK 16'-11 1/2" 4 12 5 12 14'-8 1/2" 9'-7" 5'-1" 4'-5 1/2" TRASH CHUTE ACCESS DOOR RECYCLE CHUTE ACCESS DOOR ELECT. 223 EAST SHAFT 234 EAST HALL 221 TRASH CHUTES 222 3'-8 1/4" 5'-10 3/4" LEVEL 1 100' - 0" LEVEL 2 111' - 6" LEVEL 3 122' - 4" 16'-11 1/2" 5'-6" TRASH AND RECYCLING CHUTE ACCESS DOORS OVERHEAD EXTERIOR DOOR (4) 4 YARD DUMPSTER 3'-8 1/4" TRUSS BEARING 131' - 6" UNIT 2.1 D W HANGING BICYCLE STORAGE IN EACH RESIDENTIAL UNIT UNIT 1.1 109 INTERIOR BICYCLE STORAGE: (4) INVERTED U-RACKS EAST ENTRY 117 WATER ENTRY 119 ELECTRICAL 120 EAST HALL 121 LEVEL 1 100' - 0" BRICK SITE WALL W/ CONCRETE CAP IN THE COURTYARD FOR ACOUSTIC MITIGATION FROM DRAKE & TRAIN TRACKS. RE: LANDSCAPE PLAN 8'-4" ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION PROJECT No.: DRAWN: DRAWING NUMBER: REVIEWED: OF 13 LAND PLANNER RIPLEY DESIGN INC. 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 OWNER VOLUNTEERS OF AMERICA 2660 Larimer Street Denver, CO 80205 p. 303.297.0408 ARCHITECT SHOPWORKS ARCHITECTURE 301 W. 45th Avenue Denver, CO 80216 p. 303.433.4094 ENGINEER JVA INC. CONSULTING ENGINEERS 213 Linden Street, Suite 200 Fort Collins, CO 80524 p. 970.225.9099 SEAL: 0 05 10 20 NORTH SCALE: 1" = 10'-0" ORIGINAL SIZE 24X36 ISSUED No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE PROJECT DEVELOPMENT PLAN FORT COLLINS, CO PREPARED BY: ELECTRICAL ENGINEER MV CONSULTING 4640 Pecos Street, Unit F Denver, CO 80211 p. 303.325.3271 1 PDP 2019/2/27 2 PDP 2 2019/4/3 3 P & Z REVISIONS 2019/4/29 4 FDP 2020/8/5 5 FDP 2 2020/10/14 AP ARCHITECTURAL DETAILS 13 17033 VOA SENIOR RESIDENCES 1 1/4" = 1'-0" TYPICAL UNIT BICYCLE STORAGE 2 1/4" = 1'-0" EAST ENTRY BICYCLE STORAGE 3 1/4" = 1'-0" SITE WALL ELEVATION 6 MYLARS 2020/11/17 320 UNIT 2.1 220 DUMPSTER ROOM 122 TRASH CHUTES 222 TRASH CHUTES 322 EAST STAIR 131 1 HR RATED TRASH CHUTE SHAFT 11'-6" 10'-10" 9'-2" LEVEL 1 100' - 0" LEVEL 2 111' - 6" LEVEL 3 122' - 4" 19'-4 1/2" 9'-7" TRASH & RECYCLING CHUTES (4) 4 YARD DUMPSTERS DUMPSTER ROOM 122 TRASH CHUTES 222 TRASH CHUTES 322 TRUSS BEARING 131' - 6" ELECT. 223 ELECT 323 EAST SHAFT 148 EAST SHAFT 336 EAST SHAFT 234 1 HR RATED DUMPSTER ROOM & SHAFT 11'-6" 10'-10" 9'-2" ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION PROJECT No.: DRAWN: DRAWING NUMBER: REVIEWED: OF 13 LAND PLANNER RIPLEY DESIGN INC. 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 OWNER VOLUNTEERS OF AMERICA 2660 Larimer Street Denver, CO 80205 p. 303.297.0408 ARCHITECT SHOPWORKS ARCHITECTURE 301 W. 45th Avenue Denver, CO 80216 p. 303.433.4094 ENGINEER JVA INC. CONSULTING ENGINEERS 213 Linden Street, Suite 200 Fort Collins, CO 80524 p. 970.225.9099 SEAL: 0 05 10 20 NORTH SCALE: 1" = 10'-0" ORIGINAL SIZE 24X36 ISSUED No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE PROJECT DEVELOPMENT PLAN FORT COLLINS, CO PREPARED BY: ELECTRICAL ENGINEER MV CONSULTING 4640 Pecos Street, Unit F Denver, CO 80211 p. 303.325.3271 1 PDP 2019/2/27 2 PDP 2 2019/4/3 3 P & Z REVISIONS 2019/4/29 4 FDP 2020/8/5 5 FDP 2 2020/10/14 AP TRASH AND RECYCLE DETAILS 12 17033 VOA SENIOR RESIDENCES 1 1/4" = 1'-0" LEVEL 1 DUMPSTER ROOM PLAN 2 1/4" = 1'-0" LEVEL 2&3 TRASH CHUTE ACCESS 4 1/4" = 1'-0" TRASH CHUTE SECTION FACING NORTH 5 1/4" = 1'-0" TRASH CHUTE SECTION FACING EAST 6 MYLARS 2020/11/17 FIXTURE TYPE SE4 NO SCALE 7 FIXTURE TYPE SE5,SE5A NO SCALE 1 SE2 PARKING POLE BASE DETAIL NO SCALE Schedule Symbol Label Manufacturer Catalog Number Description Lamp Number Lamps Lumens Per Lamp Light Loss Factor Wattage SE1 1 4207 1 38 SE2 1 9410 1 108 SE3 1 1339 1 14.4 SE4 1 1292 0.75 13.9 SE5 1 5573 1 70 SE5A 1 5244 1 70 SE7 Kelvix 890 0.3 1.1 LED 4000K 6 " APERTURE RECESSED DOWNLIGHT LED PEDESTRIAN POLE LED FULL CUT OFF TYPE FORWARD THROW OPTICS 12'-0" AFG PEDESTRIAN POLE LIGHT LED FULL CUT OFF TYPE 5 OPTICS 12'-0" AFG LSI INDUSTRIES, INC LSI INDUSTRIES, INC LSI INDUSTRIES, INC LSI INDUSTRIES, INC LSI INDUSTRIES, INC LSI INDUSTRIES, INC XWM-FT-LED-04-30 XENM3-SA-3-LED-64- HO-CW CYL6-S-14-LED-40-BK-HZ L6-13-LED-30-62-TR6R- HZ-WH XENM3-PT-FT-LED-SS- CW XENM3-PT-5-LED-SS-CW WALL MOUNT LED FULL CUT OFF FORWARD THROW OPTICS 12'-0" AFG ARCHITECTURAL AREA LIGHT LED FULL CUT OFF TYPE 3 OPTICS 20'-0" AFG 6 " APERTURE WALL MOUNT CYLINDER DOWNLIGHT 10'-0" AFG SE6 GROUNG MOUNTED LED FLOOD LIGHT 1 705 1 10 (FLAG POLES) EXCELSIOR LIGHTING FA-1L BZ LED 3000K LED 5000K LED 3000K LED 5000K LED 5000K LED 3000K SX-30K-300-24V HORIZONTAL BENDING LINEAR LED RUBBER COATED OUTDOOR RATED TAPE LIGHT. MOUNTED UNDER BENCH LED 3000K 1 8 FIXTURE TYPE SE6 NO SCALE 9 FIXTURE TYPE SE7 NO SCALE 9 OF 13 SITE LIGHTING DETAILS PROJECT No.: DRAWN: DRAWING NUMBER: REVIEWED: LAND PLANNER RIPLEY DESIGN INC. 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 OWNER VOLUNTEERS OF AMERICA 2660 Larimer Street Denver, CO 80205 p. 303.297.0408 ARCHITECT SHOPWORKS ARCHITECTURE 301 W. 45th Avenue Denver, CO 80216 p. 303.433.4094 ENGINEER JVA INC. CONSULTING ENGINEERS 213 Linden Street, Suite 200 Fort Collins, CO 80524 p. 970.225.9099 SEAL: 0 05 10 20 NORTH SCALE: 1" = 10'-0" ORIGINAL SIZE 24X36 ISSUED No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE PROJECT DEVELOPMENT PLAN FORT COLLINS, CO PREPARED BY: ELECTRICAL ENGINEER MV CONSULTING 4640 Pecos Street, Unit F Denver, CO 80211 p. 303.325.3271 1 PDP 2019/2/27 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION JJK MTV 2019-011-00 VOA SENIOR RESIDENCES C:\Users\kevin\appdata\local\temp\AcPublish_11552\PH-SITE LIGHTING DETAILS.dwg Kevin 10.14.20 10:41 am 2 PDP 2 2019/4/3 3 FDP 2020/8/5 5 FDP2 2020/10/14 6 MYLARS 2020/11/17 0.0 0.0 0.0 0.0 0.1 0.7 5.7 6.7 6.8 6.7 1.2 0.5 0.9 4.7 6.6 4.2 1.6 0.8 2.1 3.7 3.9 4.8 3.9 3.5 2.3 1.1 0.6 0.3 0.0 0.0 0.0 0.0 0.1 0.7 0.7 1.2 3.1 3.1 4.1 1.4 0.8 1.6 5.3 5.4 4.1 1.9 4.4 5.3 5.4 6.5 5.3 4.8 3.4 1.4 0.7 0.3 0.0 0.1 0.1 0.1 0.7 6.0 6.4 4.7 2.6 4.4 1.4 0.8 1.3 2.1 2.0 2.0 2.0 4.1 7.4 6.2 5.4 5.0 3.8 4.2 3.2 1.5 0.8 0.4 0.1 0.1 0.2 0.3 3.6 7.6 3.4 3.5 2.2 1.5 2.0 1.0 0.6 0.7 0.8 0.8 1.4 2.6 3.6 4.8 5.0 3.4 2.6 1.9 1.9 1.5 1.0 0.5 0.3 0.1 0.2 0.5 0.7 2.9 1.5 2.2 2.9 2.4 2.0 1.4 1.2 0.8 0.7 0.3 0.2 0.1 0.3 0.9 1.9 3.4 0.6 0.8 1.9 2.6 2.8 1.9 1.4 1.0 0.8 0.2 0.1 0.1 0.4 1.1 3.5 6.2 0.3 0.6 2.5 4.4 4.5 2.6 2.3 1.9 1.4 0.3 0.1 0.1 0.4 1.1 3.5 3.7 2.8 0.2 0.5 4.0 6.0 5.2 3.1 4.0 4.1 2.7 0.4 0.1 0.1 0.3 0.9 1.8 1.8 1.6 0.1 0.3 3.6 5.3 4.0 3.1 4.6 5.7 4.1 0.5 0.1 0.1 0.2 0.5 0.6 0.7 0.6 5.5 0.1 1.8 3.9 5.0 4.9 2.9 3.5 4.5 3.2 0.2 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.0 0.0 6.6 1.0 4.4 3.8 3.7 3.6 4.1 4.0 3.0 4.5 5.1 3.6 0.5 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 6.0 5.5 5.0 4.0 5.8 4.1 2.7 2.0 2.2 2.3 3.7 3.7 2.5 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.6 3.1 4.1 5.9 3.1 2.2 1.4 1.1 1.4 1.6 2.0 1.7 1.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.9 2.0 4.0 3.7 2.1 0.9 0.8 0.7 1.0 1.2 1.2 1.1 0.7 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 1.5 2.3 1.9 1.1 0.6 0.6 0.7 0.9 1.2 1.1 0.9 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 1.2 1.5 1.7 1.1 0.6 0.4 0.6 1.2 1.8 1.6 1.2 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 1.2 2.6 2.9 1.7 0.7 0.4 0.6 1.6 3.6 3.6 2.0 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.5 1.7 4.0 4.8 2.1 0.8 0.5 0.6 1.9 4.5 4.5 3.1 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.6 0.4 2.4 6.5 5.4 2.4 1.0 0.6 0.7 1.7 3.0 4.3 1.8 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.7 4.1 0.4 2.4 6.5 5.4 2.6 1.3 1.0 1.0 2.0 4.6 5.2 3.5 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.6 3.9 0.4 1.6 4.0 4.9 2.6 1.9 1.8 1.5 1.9 3.9 3.8 2.1 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.2 1.0 2.5 3.1 2.5 2.9 3.8 3.3 1.9 2.0 1.7 1.1 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.8 1.4 1.9 2.0 3.3 5.3 4.2 1.4 1.1 0.7 0.6 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1.4 1.5 1.9 2.0 3.2 4.1 4.5 0.9 0.6 0.3 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 2.5 2.1 2.7 2.7 3.8 6.0 5.7 1.2 0.5 0.2 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.5 2.9 4.1 4.8 3.5 3.5 4.8 3.8 1.0 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 2.8 5.6 6.0 4.0 2.9 2.9 2.0 0.8 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 1.4 4.5 3.9 3.5 2.5 2.5 1.6 0.8 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.8 4.4 5.5 3.8 3.2 3.7 2.9 1.0 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.4 0.8 6.1 0.2 0.8 3.3 4.2 3.4 3.6 5.2 3.9 1.2 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.6 1.2 1.6 7.1 0.0 0.1 0.5 1.5 2.2 2.5 3.6 5.3 5.5 1.1 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 1.1 2.9 4.0 7.7 5.5 4.2 2.7 0.1 0.1 0.4 1.3 1.9 2.4 3.9 6.1 6.3 1.0 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.6 1.3 3.2 2.5 4.2 1.5 0.5 0.2 0.1 0.1 0.5 1.9 2.7 3.1 3.5 4.8 3.7 0.8 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.8 1.6 2.1 3.6 3.3 3.0 1.3 0.4 0.2 0.1 0.1 0.5 3.2 4.6 4.4 3.0 2.8 1.9 0.6 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 1.2 3.5 3.0 4.7 2.0 1.2 0.7 0.3 0.1 0.1 0.2 0.6 4.9 6.6 4.7 2.2 1.4 0.8 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 1.1 3.8 2.0 4.9 1.4 0.6 0.3 0.2 0.1 0.1 0.1 0.5 4.5 5.8 4.0 1.6 0.8 0.4 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 1.0 2.4 2.2 2.7 1.1 0.4 0.2 0.1 0.1 0.0 0.1 0.5 3.4 4.6 3.9 1.5 0.6 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 0.9 0.7 0.9 0.6 0.3 0.1 0.1 0.0 0.0 0.1 0.4 2.3 3.1 2.9 1.2 0.5 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.2 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.2 1.1 1.3 1.3 0.8 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 1 E-4 SITE PHOTOMETRIC PLAN 1" = 20'-0" GENERAL NOTES 1. ANY PROPOSED LIGHT FIXTURES INSTALLED ON PRIVATE PROPERTY, ADJACENT TO THE PUBLIC ROW, SHALL BE ORIENTED IN SUCH A MANNER OR LIMITED IN LUMEN OUTPUT TO PREVENT GLARE PROBLEMS AND SHALL NOT EXCEED NATIONAL I.E.S. LIGHTING STANDARDS FOR DISABILITY GLARE. EXISTING SITE POLE SHOWN FOR REFERENCE LUMEN OUTPUT NOT INCLUDED IN CALCULATION. EXISTING SITE POLE SHOWN FOR REFERENCE LUMEN OUTPUT NOT INCLUDED IN CALCULATION. SE1 SE1 SE2 SE2 SE2 SE5 SE4 SE4 SE4 SE4 SE4 SE4 SE1 SE2 SE2 SE2 SE5A SE5A SE2 SE2 SE2 SE4 SE5A SE5 SE4 SE4 SE2 EXISTING SITE POLE SHOWN FOR REFERENCE LUMEN OUTPUT NOT INCLUDED IN CALCULATION. SE4 SE4 SE4 SE4 SE7 SE6 SE6 SE6 Statistics Description Symbol Avg Max Min Max/Min Avg/Min Calc Zone #1 1.4 fc 7.7 fc 0.0 fc N/A N/A NEW SITE POLE ADDED AS REQUESTED AND IS SHOWN FOR REFERENCE LUMEN OUTPUT NOT INCLUDED IN CALCULATION. SE1 DETAIL NOTES 1 PER THE FEDERAL FLAG CODE, UPLIGHTING OF THE FLAG IS REQUIRED WHEN THE FLAG IS FLOWN AT NIGHT. 2 FIXTURE IS LOCATED AT THE BOTTOM OF THE SEAT CAP AND POINTING DOWN. 1 1 1 2 8 OF 13 SITE PHOTOMETRIC PLAN PROJECT No.: DRAWN: DRAWING NUMBER: REVIEWED: LAND PLANNER RIPLEY DESIGN INC. 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 OWNER VOLUNTEERS OF AMERICA 2660 Larimer Street Denver, CO 80205 p. 303.297.0408 ARCHITECT SHOPWORKS ARCHITECTURE 301 W. 45th Avenue Denver, CO 80216 p. 303.433.4094 ENGINEER JVA INC. CONSULTING ENGINEERS 213 Linden Street, Suite 200 Fort Collins, CO 80524 p. 970.225.9099 SEAL: 0 05 10 20 NORTH SCALE: 1" = 10'-0" ORIGINAL SIZE 24X36 ISSUED No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE PROJECT DEVELOPMENT PLAN FORT COLLINS, CO PREPARED BY: ELECTRICAL ENGINEER MV CONSULTING 4640 Pecos Street, Unit F Denver, CO 80211 p. 303.325.3271 1 PDP 2019/2/27 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION JJK MTV 2019-011-00 VOA SENIOR RESIDENCES C:\Users\kevin\appdata\local\temp\AcPublish_11552\PH-PHOTOMETRIC.dwg Kevin 10.14.20 10:41 am 2 PDP 2 2019/4/3 3 FDP 2020/8/5 5 FDP2 2020/10/14 6 MYLARS 2020/11/17 6.32 6.29 6.31 7.08 6.30 7.33 14.02 6.28 6.32 6.29 23.01 26.03 8.05 4.03 8.02 5.21 5.21 6.31 5.06 6.32 4.02 7.08 6.28 39'-10" 11'-6" 10'-10" 17'-6" 169'-7" TO PROPERTY LINE 10.02 ELEVATIONS MATERIAL LEGEND BRICK VENEER, NORMAN PAINTED CEMENT BOARD TRIM CEMENT BOARD LAP SIDING 6" EXPOSURE STANDING SEAM METAL ROOF ASPHALT SHINGLE ROOF CEMENT BOARD PANEL COLORED TPO ROOF ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION PROJECT No.: DRAWN: DRAWING NUMBER: REVIEWED: OF 13 LAND PLANNER RIPLEY DESIGN INC. 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 OWNER VOLUNTEERS OF AMERICA 2660 Larimer Street Denver, CO 80205 p. 303.297.0408 ARCHITECT SHOPWORKS ARCHITECTURE 301 W. 45th Avenue Denver, CO 80216 p. 303.433.4094 ENGINEER JVA INC. CONSULTING ENGINEERS 213 Linden Street, Suite 200 Fort Collins, CO 80524 p. 970.225.9099 SEAL: 0 05 10 20 NORTH SCALE: 1" = 10'-0" ORIGINAL SIZE 24X36 ISSUED No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE PROJECT DEVELOPMENT PLAN FORT COLLINS, CO PREPARED BY: ELECTRICAL ENGINEER MV CONSULTING 4640 Pecos Street, Unit F Denver, CO 80211 p. 303.325.3271 1 PDP 2019/2/27 2 PDP 2 2019/4/3 3 P & Z REVISIONS 2019/4/29 4 FDP 2020/8/5 5 FDP 2 2020/10/14 AP BUILDING ELEVATIONS 7 EP 17033 VOA SENIOR RESIDENCES 1 1/16" = 1'-0" North Elevation 2 1/16" = 1'-0" East Elevation FLAGNOTES 4.01 BRICK SOLDIER COURSE 4.02 4" NORMAN BRICK VENEER, COLOR #1 4.03 4" NORMAN BRICK VENEER, COLOR #2 4.04 4" NORMAN BRICK VENEER, COLOR #3 4.05 BRICK ROWLOCK WINDOW SILL 4.06 RECESSED BRICK FACADE DETAIL 4.07 BRICK SITE WALL FOR COURTYARD ACOUSTIC MITIGATION 5.06 FABRICATED PREFINISHED 20-GA. STEEL GUTTER & DOWNSPOUT 5.21 STANDING SEAM METAL ROOF 6.19 EXTERIOR DOUGLAS FIR GLULAM COLUMN, STAINED AND SEALED, RE: STRUCTURAL 6.28 1X4 FIELD PAINTED CEMENT BOARD TRIM 6.29 1X6 FIELD PAINTED CEMENT BOARD TRIM 6.30 FIELD PAINTED CEMENT BOARD 6.31 FIELD PAINTED CEMENT BOARD FASCIA 6.32 FIELD PAINTED 6" CEMENT BOARD LAP SIDING 7.08 ASPHALT SHINGLE SLOPED ROOF 7.18 COLORED TPO ROOFING, MEDIUM BRONZE 7.33 PREFINISHED, CONTINUOUS 24 GA METAL PARAPET WALL COPING, COUNTER FLASHING & CLEAT 8.02 FIBER COMPOSITE WINDOW @ NON-RESIDENTIAL SPACES, B.O.D.: ANDERSEN 100 SERIES 8.03 VINYL WINDOW, TYP. @ RESIDENTIAL UNITS 8.05 INSULATED HOLLOW METAL FRAME DOOR IN HM FRAME @ EXTERIOR DOORS 8.06 OVERHEAD SECTIONAL EXTERIOR DOOR 8.11 AUTOMATIC SLIDING DOOR @ ENTRY VESTIBULE 10.02 METAL BUILDING SIGNAGE 14.02 TRASH & RECYCLE CHUTES 23.01 MECHANICAL EQUIPMENT ON FACTORY CURB & 6" CONCRETE PAD, RE: MECHANICAL 23.03 CONDENSING UNITS ON NEOPRENE PAD, ON 2X FRAMED PLATFORM W/ LINESETS, RE: MECHANICAL 26.03 ELECTRIC METERS, RE: ELECTRICAL 6 MYLARS 2020/11/17 5.21 6.19 5.21 6.31 4.01 8.05 23.01 6.30 7.08 6.32 5.06 4.05 4.06 6.28 6.29 39'-10" 11'-6" 10'-10" 17'-6" 7.18 4.02 4.01 4.04 ELEVATIONS MATERIAL LEGEND BRICK VENEER, NORMAN PAINTED CEMENT BOARD TRIM CEMENT BOARD LAP SIDING 6" EXPOSURE STANDING SEAM METAL ROOF ASPHALT SHINGLE ROOF CEMENT BOARD PANEL COLORED TPO ROOF ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION PROJECT No.: DRAWN: DRAWING NUMBER: REVIEWED: OF 13 LAND PLANNER RIPLEY DESIGN INC. 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 OWNER VOLUNTEERS OF AMERICA 2660 Larimer Street Denver, CO 80205 p. 303.297.0408 ARCHITECT SHOPWORKS ARCHITECTURE 301 W. 45th Avenue Denver, CO 80216 p. 303.433.4094 ENGINEER JVA INC. CONSULTING ENGINEERS 213 Linden Street, Suite 200 Fort Collins, CO 80524 p. 970.225.9099 SEAL: 0 05 10 20 NORTH SCALE: 1" = 10'-0" ORIGINAL SIZE 24X36 ISSUED No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE PROJECT DEVELOPMENT PLAN FORT COLLINS, CO PREPARED BY: ELECTRICAL ENGINEER MV CONSULTING 4640 Pecos Street, Unit F Denver, CO 80211 p. 303.325.3271 1 PDP 2019/2/27 2 PDP 2 2019/4/3 3 P & Z REVISIONS 2019/4/29 4 FDP 2020/8/5 5 FDP 2 2020/10/14 AP BUILDING ELEVATIONS 6 EP 17033 VOA SENIOR RESIDENCES 1 1/16" = 1'-0" South Elevation 2 1/16" = 1'-0" West Elevation FLAGNOTES 4.01 BRICK SOLDIER COURSE 4.02 4" NORMAN BRICK VENEER, COLOR #1 4.03 4" NORMAN BRICK VENEER, COLOR #2 4.04 4" NORMAN BRICK VENEER, COLOR #3 4.05 BRICK ROWLOCK WINDOW SILL 4.06 RECESSED BRICK FACADE DETAIL 4.07 BRICK SITE WALL FOR COURTYARD ACOUSTIC MITIGATION 5.06 FABRICATED PREFINISHED 20-GA. STEEL GUTTER & DOWNSPOUT 5.21 STANDING SEAM METAL ROOF 6.19 EXTERIOR DOUGLAS FIR GLULAM COLUMN, STAINED AND SEALED, RE: STRUCTURAL 6.28 1X4 FIELD PAINTED CEMENT BOARD TRIM 6.29 1X6 FIELD PAINTED CEMENT BOARD TRIM 6.30 FIELD PAINTED CEMENT BOARD 6.31 FIELD PAINTED CEMENT BOARD FASCIA 6.32 FIELD PAINTED 6" CEMENT BOARD LAP SIDING 7.08 ASPHALT SHINGLE SLOPED ROOF 7.18 COLORED TPO ROOFING, MEDIUM BRONZE 7.33 PREFINISHED, CONTINUOUS 24 GA METAL PARAPET WALL COPING, COUNTER FLASHING & CLEAT 8.02 FIBER COMPOSITE WINDOW @ NON-RESIDENTIAL SPACES, B.O.D.: ANDERSEN 100 SERIES 8.03 VINYL WINDOW, TYP. @ RESIDENTIAL UNITS 8.05 INSULATED HOLLOW METAL FRAME DOOR IN HM FRAME @ EXTERIOR DOORS 23.01 MECHANICAL EQUIPMENT ON FACTORY CURB & 6" CONCRETE PAD, RE: MECHANICAL 26.03 ELECTRIC METERS, RE: ELECTRICAL 6 MYLARS 2020/11/17