October 08, 2013
Dennis Messner
Dennis R. Messner, P.E.
1355 N. Cleveland Ave., Ste #1
Loveland, CO 80537
RE: Whitman Storage Facility II and Addition of a Permitted Use, PDP130031, Round Number 1
Community Development and
Neighborhood services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224 6134 - fax
fcgov. com/developmentreview
Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of
the above referenced project. If you have questions about any comments, you may contact the individual
commenter or direct your questions through the Project Planner, Kiana Carter, at or kcarter.
Comment Summary:
Department: Current Planning
Contact: Lindsay Ex, 970.224-6143, lex(@fcgov.com
Topic: General
Comment Number: 8
Comment Originated: 10/08/2013
10/08/2013: Illustrations would be helpful to show existing conditions vs. proposed and how it meets
the criteria of the APU. I would also suggest including a context map within the revised APU submittal
that shows surrounding uses. I would also revise the request to directly align with the requirements of
the APU criteria outlined in Section 1.3.4 of the Land Use Code.
Contact: Noah Beals, 970.416-2313, nbealscDfcgov.com
Topic: General
Comment Number: 1
Comment Originated: 09/20/2013
09/20/2013: The application is confusing, it appears that the previous APU was cut and pasted into this
APU request. Some things that were necessary with the previous application are not necessary with
this one and some things needed with this one are not included. Please revise the submittal to
update it with the current proposal.
Comment Number: 2 Comment Originated: 09/20/2013
09/20/2013: The site plan and landscape plan should clearly delineate what is existing and what are
the proposed improvements.
Comment Number: 3 Comment Originated: 09/20/2013
09/20/2013: The elevations should only include the items that are being proposed and not what
already is approved and existing.
Page 1 of 7
Comment Number: 4 Comment Originated: 09/20/2013
09/20/2013: The Fencing and Landscaping that was approved for the first APU should be the starting
point for the proposal of the required screening for the area of the new APU.
Land Use Code (LUC) section 3.2.1(E)(6) Screening for areas of low visual interest such as open
storage is required. This screening shall be established on all sides.
Land Use Code (LUC) section 3.2.1
Comment Number: 5 Comment Originated: 09/20/2013
09/20/2013: LUC 3.2.1(D) Full tree stocking is required in landscape areas within 50 of a structure.
The fence should include more articulation on all sides and such articulation should be big enough to
accommodate tree stocking.
Comment Number: 6 Comment Originated: 09/20/2013
09/20/2013: The landscape plan will need to include details of the size of the plantings at time of
installation.
Comment Number: 7 Comment Originated: 09/20/2013
09/20/2013: LUC 3.8.11(B) Chain -Link is prohibited to be used for required screening.
Department: Engineering Development Review
Contact: Sheri Langenberger, 970.221-6573, slangenberger@fcgov.com
Topic: General
Comment Number: 1
Comment Originated: 09/16/2013
09/16/2013: The project owes an additonal $905 for the PDP TDRFees. Per the site plan the site is
6.82 acres not 3.2 as indicated on the application.
Contact: Tyler Siegmund, 970.221.6501, tsiegmund(a?fcgov.com
Topic: General
Comment Number: 2 Comment Originated: 10/01/2013
10/01/2013: It appears the utility and drainage easements referenced on the site and grading plans
are existing. Do any additional easements need to be dedicated as part of this project for the
detention ponds ect? There is a process to dedicate easements by separate document. Please
contact me for information about dedicating easements by separate document or visit
http://www.fcgov.com/engineering/devrev.php. for additional information.
Comment Number: 3 Comment Originated: 10/01/2013
10101/2013: All of the notes on the site plan are outdated and should reflect the existing conditions on
the site. It appears the notes reflect the original submittal for Whitman Storage Facility. Please update
the notes to reflect Whitman Storage Facility ll.
Page 2 of 7
Comment Number: 4
Comment Originated: 10/01/2013
10/01/2013: Per the existing Development Agreement for Whitman Storage, section D.3 identifies the
developers responsibility for construction of the local street portion of the public streets adjacent to the
property, prior to the issuance of the first building permit. The developers responsibility for Aaron St
and Cherylen St at the rear of the property still remain but will not be built or designed as part of this
project approval. A new development agreement will need to be recorded as part of this project to
identify the developers responsibility of the public streets adjacent to the site but design and
construction of the public streets will be delayed until such time as the City deems the improvements
necessary or with additional changes to the property that will require issuance of a building permit.
Comment Number: 5 Comment Originated: 10/01/2013
10/01/2013: Please update note #19 on the Cover Sheet to reference Whitman Storage Facility II
dated August 2013.
Comment Number: 6
Comment Originated: 10/01/2013
10/01/2013: Please revise note #48 on the Cover Sheet- there are no requested or approved
variances as part of this project- Whitman Storage Facility II.
Department: Environmental Planning
Contact: Lindsay Ex, 970-224-6143, lex(a.fcgov.com
Topic: General
Comment Number: 1
Comment Originated: 10/01/2013
10/01/2013: An Ecological Characterization Study, in accordance with the requirements of Section
3.4.1 of the Land Use Code, was not submitted with this PDP - please submit the required ECS (as
outlined in my conceptual review comments).
In addition to the typical requirements outlined in Section 3.4.1 of the Land Use Code, the ECS should
address the wetland that was filled (0.365 acres), how the wetland will be mitigated for, the concurrence
of the Army Corps of Engineers of the findings (in written form, email or letter), and the
grading/landscaping required to achieve the ecological goals of the filled wetland.
Comment Number: 2
Comment Originated: 10/01/2013
10/01/2013: The current grading and landscape plan for the wetland is insufficient -the wetland grading
and proposed plant material will need to be determined after the ECS has been submitted.
Comment Number: 3
Comment Originated: 10/01/2013
10/01/2013: Is there lighting proposed in the storage area? If so, none can spillover into the wetland
area or the buffer around the wetland.
Comment Number: 4
Comment Originated: 10/01/2013
10/01/2013: A wetland mitigation and monitoring plan will need to be submitted at the time of final
plans. with a security, e.g., an escrow or bond, to ensure that the mitigation will be accomplished.
Comment Number: 5
Comment Originated: 10/01/2013
10/01/2013: How will adverse impacts, e.g., from fuel spills, be addressed on the site so as not to
impact the Prairie Dog Meadows Natural Area?
Department: Forestry
Contact: Tim Buchanan, 970.221.6361, tbuchanan aMcgov.com
Topic: Landscape Plans
Page 3 of 7
Comment Number: 1 Comment Originated: 10/08/2013
10/08/2013:
Street Tree comments:
Please use Greenspire Linden in place of Redmond Linden along Skyway.
The first street tree west of the curb cut is too close to the curb cut.
Are the gaps in the row of street trees for street lights? If they are then show locations of street lights. If
not provide a continuous row of street trees.
Comment Number: 2 Comment Originated: 10/08/2013
10/0812013:
Planting note number 2 could be changed to as follows.
Turf areas at street to be irrigated with automatic pop-up irrigation. Trees and shrubs to be irrigated with
low volume drip system.
Comment Number: 3
10108/2013:
Plant List Comments:
Comment Originated: 10/08/2013
There are three Blue spruce shown on the plans but only two listed in the plant list.
The Rocky Mountain Junipers are trees. Place them in the Evergreen tree category on the Plant List.
Comment Number: 4 Comment Originated: 10/08/2013
10/08/2013:
Please set up an on -site meeting with the City Forester to review existing trees to be retained.
Significant trees should be identified as to species size and condition.
Department: Light And Power
Contact: Doug Martine, 970.224-6152, dmartine(aVcgov.com
Topic: General
Comment Number: 1 Comment Originated: 09/19/2013
09/19/2013: Electric development charges will apply for all additional site being developed, plus for
any new or additional power requirements. Please coordinate with Light & Power Engineering at
(970)221-6700.
Department: PFA
Contact: Jim Lynxwiler, 970.416.2869, jlynxwiler(cD.poudre-fire.org
Topic: General
Page 4 of 7
Comment Number: 1
Comment Originated: 10/01/2013
10/01/2013: FIRE LANES
The proposed RV storage building remains out of fire access. It is not clear if the proposed fire lane
will provide access to all portions of the outdoor storage area. Further access details are requested
including vehicle turn around and bridge load limits.
O6 IFC 503.1.1: Fire Lanes shall be provided to within 150' of all portions of the building, as measured
by an approved route around the exterior of the building. When fire lanes cannot be provided, the fire
code official Is authorized to increase the dimension of 150 feet if the building is equipped throughout
with an approved, automatic fire -sprinkler system.
Comment Number: 2
10/01/2013: GENERAL FIRE LANE SPECIFICATIONS
Comment Originated: 10/01/2013
> Shall be designated on the plat as an Emergency Access Easement.
> Shall be designed as a flat, hard, all-weather driving surface capable of supporting 40 tons. Road
base (meeting minimum loads of 40 ton) is approved for outside storage areas.
> Dead-end fire access roads in excess of 150 feet in length shall be provided with an approved area
for turning around fire apparatus.
> Bridges shall be rated to carry fire apparatus. The load limits shall be posted on the bridge.
> Shall be visible by painting and/or signage, and maintained unobstructed at all times.
2006 International Fire Code 503.2.3, 503.2.4, 503.2.5, 503.3, 503.4 and Appendix D; FCLUC
3.6.2(B)2006 and Local Amendments.
Comment Number: 3
10/01/2013: SECURITY GATES
Comment Originated: 10/01/2013
06 IFC 503.6: The installation of security gates across a fire apparatus access road shall be approved
by the fire chief. Where security gates are installed, they shall have an approved means of emergency
operation. The security gates and the emergency operation shall be maintained operational at all
times.
Comment Number: 4 Comment Originated: 10/01/2013
10/01/2013: VEHICLE STORAGE
Buildings used for indoor storage of vehicles to be built in accordance with the IBC.
Comment Number: 5 Comment Originated: 10/01/2013
10/01/2013: PREMISE IDENTIFICATION
O6 IFC 505.1: New and existing buildings shall be plainly identified. Address numbers shall be visible
from the street fronting the property, plainly visible, and posted with a minimum of six-inch numerals on
a contrasting background.
Department: Stormwater Engineering
Contact: Wes Lamarque, 970.416.2418, wlamargueMcaov.com
Topic: Erosion Control
Page 5 of 7
Comment Number: 1 Comment Originated: 10/04/2013
09/17/2013: The site disturbs more than 10,000 sq-ft, therefore Erosion and Sediment Control Materials
need to be submitted for FDP. The erosion control requirements are in the Stormwater Design Criteria
under the Amendments of Volume 3 Chapter 7 Section 1.3.3. (Requirements added to the packet of
Materials from Stormwater) Current Erosion Control Materials Submitted does not meet requirements.
Please submit; Erosion Control Plan, Erosion Control Report, and an Escrow / Security Calculation. If
you need clarification concerning this section, or if there are any questions please contact Jesse
Schlam 970-218-2932 or email @ jschlam@fcgov.com
Topic: General
Comment Number: 2 Comment Originated: 10/04/2013
10/04/2013: The storm sewer along the north side of the property is very shallow and currently
damaged. This conveyance, which is required to convey 87 cfs needs to be improved to City
standards.
Comment Number: 3 Comment Originated: 10/04/2013
10/04/2013: Please include forebays in the drainage and detention design. Please coordinate with
the City on the design of these forebays.
Comment Number: 3 Comment Originated: 10/04/2013
10/04/2013: Please discuss the drainage of off -site basin 2 and how it is conveyed through the site in
the text of the drainage report.
Department: Technical Services
Contact: Jeff County, 970.221-6588, icounty(o)fcgov.com
Topic: Building Elevations
Comment Number: 1 Comment Originated: 10/02/2013
10102/2013: No comments.
Topic: Construction Drawings
Comment Number: 2 Comment Originated: 10/02/2013
10/02/2013: The titles of sheets 4 & 5 shown in the index on sheet 1, do not match the titles on each of
those sheets. See redlines.
Comment Number: 3 Comment Originated: 10/02/2013
10/02/2013: Benchmark 48-94 is no longer in the Vertical Control Network. Please replace it with
another benchmark.
Comment Number: 4 Comment Originated: 10/02/2013
10/02/2013: There are line over text issues on sheets 2, 3, 4 & 5. See redlines.
Comment Number: 5 Comment Originated: 10/02/2013
10/02/2013: There is text that needs to be rotated 180 degrees on sheets 2, 3, 4 & 5. Text should be
read from the bottom and/or the right side of the plan sheets. See redlines.
Comment Number: 6 Comment Originated: 10/02/2013
10/02/2013: There are text over text issues on sheet 3. See redlines.
Topic: Landscape Plans
Comment Number: 7 Comment Originated: 10/02/2013
10/0212013: There are line over text issues on sheets 2, 4 & 5. See redlines.
Page 6 of 7
Comment Number: 8
Comment Originated: 10/02/2013
10/02/2013: There is text that needs to be rotated 180 degrees on sheet 4. Text should be read from
the bottom and/or the right side of the plan sheets. See redlines.
Topic: Site Plan
Comment Number: 9 Comment Originated: 10/02/2013
10/02/2013: There are line over text issues on sheet 1. See redlines.
Comment Number: 10 Comment Originated: 10/02/2013
10/02/2013: There is text that needs to be rotated 180 degrees on sheet 1. Text should be read from
the bottom and/or the right side of the plan sheets. See redlines.
Department: Zoning
Contact: Peter Barnes, 970.416-2355, pbarnes(dfcgov.com
Topic: General
Comment Number: 1 Comment Originated: 09/20/2013
09/20/2013: The request for an addition of permitted use to this CL zoned property requires a Type 2
review.
Comment Number: 5
Comment Originated: 09/20/2013
09/20/2013: Clearly label Sheets 2 and 3 as Existing Development. Delineate and label on Sheet 1
the portion that is the existing, approved development to be amended.
Topic: Site Plan
Comment Number: 2
Comment Originated: 09/20/2013
09/20/2013: The site plan, Sheet 1, indicates that the use of Lot 3 of the existing Whitman Storage
Facility development plan (the previously approved plan) is for RV's, Boats, Vehicle and Truck
Storage. The actual approved use of that lot was just for RV's. Boats, and truck storage. It didn't
include 'vehicles'. If storage of vehicles such as cars is intended to be added as an allowed use on
the existing development, that needs to be clearly stated in the narrative and on the amended
development plan.
Comment Number: 3 Comment Originated: 09/20/2013
09/20/2013: The 9' tall solid metal fence should be installed along the south side of the lot for
screening instead of the proposed 8' tall chain link fence. Residential development exists adjacent
(nearby) to the south side of the development. Also, it looks like the 9' tall metal screen fence along
the east lot line is proposed for only about 1/2 of the length of the east lot line. An 8' tall chain link
fence is proposed for the other half of the east lot line. Since the outdoor storage area is required to
be screened from view per Section 3.5.1(I) of the Land Use Code, the chain link fence is not an
acceptable screen and the solid metal fence should be extended along the east lot line.
Comment Number: 4 Comment Originated: 09/20/2013
09/20/2013: Indicate the surface material for the storage lot on the plan.
Page 7 of 7