Loading...
HomeMy WebLinkAboutTHE QUARRY BY WATERMARK - PDP200019 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSPROSPECT ROAD SHIELDS STREET LAKE STREET PITKIN STREET STUART STREET HOBBIT ST. SHEELY DR. HILL POND RD. CONNECTOR LOCAL STREET SECTION MODIFIED - (HOBBIT STREET) EX. 8' PARKING LANE 10' TRAVEL LANE EX. 10' TRAVEL LANE EXISTING DRIVE-OVER CURB & GUTTER VERTICAL CURB & GUTTER 57' ROW EX . 9' UTIL. ESMT. 9' UTIL. ESMT. 4.5' WALK EX. 6' PKWY. 36' - 6' PKWY. EX. 4.5' WALK 8' PARKING LANE CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NOVEMBER 2020 UTILITY PLANS FOR CONTACT INFORMATION PROJECT TEAM: Ripley Design, Inc. 419 Canyon Avenue, Suite 200 Fort Collins, CO. 80521 (970) 224-5828 Watermark Residential 111 Monument Circle, Suite 1500 Indianapolis, IN. 46204 (317) 853-5459 UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER Northern Engineering Services, Inc. Danny Weber, PE 301 North Howes Street, Suite 100 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All sanitary sewer, storm sewer and water line construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage V.P. CABLE F.O. H Y D VAULT ELEC VAULT ELEC VAULT ELEC T E S S MH S S S S S S T S H2O TRAFFIC VAULT T S VAULT ELEC S VAULT ELEC VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR ELEC CONTROL IRR CONTROL IRR IRR W V.P. CONTROL IRR CONTROL IRR CONTROL IRR S CONTROL IRR CONTROL IRR CONTROL MH / / / / / / / / X X X X X X X X X X X X X X X X X MH MM M H / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X MCCOY JOHN H/SHERRY P 1900 S SHIELDS ST 6' SIDEWALK 5' SIDEWALK 6' SIDEWALK 6.5' SIDEWALK 6' SIDEWALK V.P. CABLE F.O. H Y D VAULT ELEC VAULT ELEC VAULT ELEC T E S S MH S S S S S S T S H2O TRAFFIC VAULT T S VAULT ELEC S VAULT ELEC VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR ELEC CONTROL IRR CONTROL IRR IRR W V.P. CONTROL IRR CONTROL IRR CONTROL IRR S CONTROL IRR CONTROL IRR CONTROL IRR CONTROL H Y D VAULT ELEC S S S S S T RAFFIC VAULT T S VAULT ELEC S VAULT ELEC VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR ELEC CONTROL IRR CONTROL IRR IRR W V.P. CONTROL IRR CONTROL IRR CONTROL IRR S CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR H Y D S S 15" SS 15" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS V.P. S S MH S S 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS X X X X X X X X X X X X X X X X X X X X FDC F UD E E E E UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD SS W W W W S S UD UD UD CABLE F.O. VAULT ELEC VAULT ELEC T E T S H2O TRAFFIC VAULT T S VAULT ELEC CONTROL IRR CONTROL IRR IRR W V.P. / / / / / / / / / / / / / / / / G G G G E E FO FO E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X X X X X X X UD UD UD UD UD UD UD UD ELEC X X X X X X X X X X X X X WINNE GRANT R/JOHNELLE S 1821 WALLENBERG DR ERIKSEN CHRISTOPHER M 1825 WALLENBERG DR MCCOY JOHN H/SHERRY P 1900 S SHIELDS ST 6' SIDEWALK UD UD UD UD F W 6' SIDEWALK PROPOSED STORM DRAIN PROPOSED RAIN GARDEN PROPOSED STORM DRAIN EXISTING 6" CMP STORM DRAIN EXISTING UNDERDRAIN 26' EMERGENCY ACCESS EASEMENT SPRING CREEK EXISTING SPRING CREEK TRAIL RAIN GARDEN BIOMEDIA AREA PROPOSED 4' SIDEWALK CULVERT TRACT B FEMA 100-YR T MH / / / / / / / / X X X X X X X X X X X X X UD S S UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD D D MH M M MH / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X UD UD UD UD / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 29' HALF ROW 6' SIDEWALK 5' SIDEWALK 6' SIDEWALK 6.5' SIDEWALK 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK 9' SIDEWALK 9' SIDEWALK 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK 4.5' SIDEWALK S SHIELDS ST. HOBBIT ST. 4.5' SIDEWALK 5' SIDEWALK 9' SIDEWALK 16.68 16.72 15.03 14.50 17.86 17.61 17.94 18.15 17.96 17.66 17.82 17.24 17.06 17.49 17.49 16.65 16.60 16.04 MH X X X X X X X X X X X X X X X X X X X X UD E E E E UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD SS S S UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH MM M H X X X X X CABLE T / / / / / / / / / / / / / / / / FO FO D D / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ST ST ST ST ST ST ST ST ST ST ST ST ST HILL POND CONDOMINIUMS 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK 13.88 15.09 16.32 16.01 16.53 16.60 17.30 16.33 16.39 16.14 15.67 15.46 14.81 FFE=17.73 FFE=17.74 17.73 17.73 16.60 17.07 17.07 17.76 17.73 2.0% 2.5% 2.0% 1.1% 0.5% X X X X X X X UD UD UD UD UD UD UD UD X X X X X X X X X X X X X WINNE GRANT R/JOHNELLE S 1821 WALLENBERG DR ERIKSEN CHRISTOPHER M 1825 WALLENBERG DR MCCOY JOHN H/SHERRY P 1900 S SHIELDS ST 6' SIDEWALK UD UD UD UD 13.88 15.09 13.10 12.07 11.55 12.43 FFE=14.99 EXISTING SPRING CREEK TRAIL EXISTING FEMA 100-YR HIGH RISK FLOOD PLAIN 14.32 14.32 14.32 14.32 1.7% 2.0% 2.0% 2.1% PROPOSED 4' CONCRETE PAN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED CABLE F.O. MH / / / / / / / / T T T T T T T T T T / / / / / / / / S UD UD S S D F.O. MH M M MH / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ST ST ST ST ST ST / / / / / / / / S UD UD h-a1 h-b2 h-b1 h-c1 h-d1 2.53 ac. H-B1 1.01 ac. H-A1 3.92 ac. CABLE F.O. MH / / / / / / / / T T T T T T T T T T / / / / / / / / S UD UD S S D F.O. MH M M MH / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ST ST ST ST ST ST UD UD UD UD / / / / / / / / S UD UD LOT 1 TRACT B TRACT A LOT 2 RAIN GARDEN A RAIN GARDEN B UD UD UD UD MH / / / / / / / / X X X X X X X X X X X X X UD E E UD UD UD UD UD UD UD UD UD UD UD UD S S UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD D D MH M M MH / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 EC2 DETAILS EROSION CONTROL 18 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R CONCRETE WASHOUT AREA CWA 2 3 ROCK SOCK DETAIL ROCK SOCK SECTION ROCK SOCK PLAN ROCK SOCK JOINTING GRADATION TABLE SIEVE SIZE MASS PERCENT PASSING SQUARE MESH SIEVES NO. 4 2" 100 1-1/2" 90-100 1" 20-55 3/4" 0-15 3/8" 0-5 MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE, ALL SIDES RS VEHICLE CONTROL TRACKING PAD VTC 4 CURB INLET PROTECTION IP 7 5 SILT FENCE AT PIPE OUTLET AREAS OF STREAMS AND DRAINAGE CHANNELS - DETAIL A IN DIVERSION DITCH OR SMALL DITCH DRAINAGE WAY - DETAIL B OUTSIDE OF STREAMS AND DRAINAGE CHANNELS - DETAIL C ANCHOR DETAILS PERIMETER ANCHOR TRENCH JOINT ANCHOR TRENCH INTERMEDIATE ANCHOR TRENCH OVERLAPPING JOINT WOOD STAKE DETAIL MINIMUM THICKNESS 1" USE 2x4 MATERIAL FOR STAKES JOINT ANCHOR TRENCH, TYP. PERIMETER ANCHOR TRENCH, TYP. TOP OF CHANNEL BANK TYPE OF BLANKET AS INDICATED IN PLAN VIEW, IN ALL DISTURBED AREAS OF STREAMS AND DRAINAGE CHANNELS TO DEPTH "D" ABOVE CHANNEL INVERT. BLANKET SHALL GENERALLY BE ORIENTED PARALLEL TO FLOW DIRECTION. STAKING PATTERN SHALL MATCH BLANKET TYPE. UNDISTURBED SOIL TYPE OF BLANKET, PER MANUFACTURER SPEC. OR TYPE 2 OR 3 STAKING INDICATED IN PLAN VIEW (MATCH SPECIFIED BLANKET TYPE) SEE THE STAKING PATTERNS DETAIL ON NEXT SHEET PERIMETER ANCHOR TRENCH, TYP. JOINT ANCHOR TRENCH, TYP. COMPACTED SUBGRADE 1 >3 THE BLANKET SHALL BE EXTENDED TO THE TOP OF CHANNEL "D" 6" TOPSOIL "M" OVERLAPPING JOINT, SEE DETAIL ON THIS SHEET STAGGER OVERLAPS PERIMETER ANCHOR TRENCH SEE DETAIL ON THIS SHEET PER MANUFACTURER SPEC. OR TYPE 1 STAKING SEE THE STAKING PATTERN DETAIL ON NEXT SHEET BLANKET SHALL BE 100% STRAW MIN. DIVERSION DITCH TYPICALLY AT TOP OF SLOPE 6" TOPSOIL 6" MIN. (TYP.) 3" MIN. (TYP.) SINGLE EDGE EROSION CONTROL BLANKET (TYP.) COMPACTED BACKFILL (TYP.) STAKE (TYP.) TWO EDGES OF TWO ADJACENT ROLLS LOOP FROM MIDDLE OF ROLL FLOW 6" 3" MIN. 12" MIN. STAKING PATTERNS SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION. IF NO MANUFACTURER'S SPECIFICATION IS AVAILABLE USE THE ACCEPTABLE STAKING PATTERN (AS SHOWN ABOVE) PERIMETER ANCHOR TRENCH OR JOINT ANCHOR TRENCH, TYP. STRAW-COCONUT COCONUT OR EXCELSIOR STRAW ROLL WIDTH "W" (TYP.) 6' 3' 1/2 "W" 1/2 "W" 1/2 "W" 1/2 "W" 1/2 "W" 4' 3' 2' ECB EROSION CONTROL BLANKET TYPE TYPE STRAW* STRAW-COCONUT EXCELSIOR COCONUT CONTENT - 30% MIN. - STRAW CONTENT 100% - NETTING MIN. DOUBLE/NATURAL 100% - - EXCELSIOR CONTENT COCONUT 100% - - * FOR OUTSIDE OF STREAMS AND DRAINAGE CHANNELS DOUBLE/NATURAL DOUBLE/NATURAL DOUBLE/NATURAL 70% MAX. 8 EROSION CONTROL BLANKET SF 1 OUTLET PROTECTION A A PLAN VIEW SECTION A-A 2:1 OP WQCV PLANTED RIPRAP INSTALLATION RP 6 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X ST ST ST ST ST ST ST WINNE GRANT R/JOHNELLE S 1821 WALLENBERG DR ERIKSEN CHRISTOPHER M 1825 WALLENBERG DR MCCOY JOHN H/SHERRY P 1900 S SHIELDS ST HILL POND CONDOMINIUMS 1S 1S 1S 1S PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 6' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED OUTFALL PIPE PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP IP OP SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF RS SF PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED STORM DRAIN RS RS RS RS RS RS RS RS RS PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN RS VTC VTC RS IP PROPOSED OUTLET STRUCTURE SF PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE CWA LOT 1 TRACT B TRACT A LOT 2 LOT 1 LOT 1 FEMA 100-YR HIGH RISK FLOOD FRINGE CITY OF FORT COLLINS 100-YR FLOODPLAIN SPRING CREEK CANAL IMPORTATION RP RP RP RP RP RP RP IP PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN RAIN GARDEN BIOMEDIA AREA RAIN GARDEN BIOMEDIA AREA PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' SIDEWALK CULVERT HOBBIT ST HOBBIT ST EXISTING SIDEWALK EXISTING SIDEWALK Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 EC1 PLAN EROSION CONTROL 17 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 60 FEET 60 60 120 180 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPOSED STORM INLET TEMPORARY BMP'S SEEDING AND MULCHING MU CONCRETE WASHOUT AREA CWA ROCK SOCK RS OUTLET PROTECTION OP SILT FENCE SF SF 1. THE LOCATION OF EROSION CONTROL MEASURES HAS BEEN SHOWN FOR REFERENCE ONLY. THE CONTRACTOR MAY ALTER THE NUMBER OR LOCATION OF THE EROSION CONTROL MEASURES AS REQUIRED. 2. ALL OFF-SITE AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESEEDED WITH A DRYLAND SEED MIX, AS SPECIFIED IN THE CITY OF LOVELAND STORMWATER SPECIFICATION SECTION 02377, PART 3, TABLE 1. 3. TOTAL DISTURBED AREA OF CONSTRUCTION = 5.91 ACRES 4. SWMP ADMINISTRATOR: Person ________________________________ Company ________________________________ Address ________________________________ Phone ________________________________ 5. CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. GENERAL NOTES: 1. IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY AS A GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF BEST MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR DIFFERENT BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY DURING CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS REQUIRED BY LOCAL AUTHORITIES. 2. THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH, GRAPHICAL SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY NECESSARILY SHOWN IN THEIR EXACT LOCATION. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY, STATE DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING AUTHORITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR PERMIT HOLDER) TO ENSURE EROSION CONTROL MEASURES ARE PROPERLY MAINTAINED AND FOLLOWED. 4. CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL MEASURES ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL OF SITE STABILIZATION. 5. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR ALL STORMWATER FACILITIES UNTIL SITE IS FULLY STABILIZED. 6. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL CONNECTION IS ESTABLISHED WITH DOWNSPOUT. 7. INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN WATTLES FOR BARE SOIL, GRAVEL SOCKS FOR PAVEMENT, ETC.) 8. CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES, PARTICULARLY THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO MULCHING, EROSION MATS, TEMPORARY IRRIGATION, AND ADDITIONAL WATTLES OR SILT FENCING MAY BE NECESSARY TO ESTABLISH VEGETATIVE COVER AND STABILIZE THE SLOPE. 9. ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE NECESSARY TO INSURE THAT EACH BUILDING PAD IS STABILIZED THROUGHOUT CONSTRUCTION. AT NO TIME SHALL SEDIMENT BE ALLOWED TO CROSS THE PUBLIC SIDEWALKS. 10. CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION FOR AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR SILT FENCE FOR BARE SOIL, SAND BAGS OR GRAVEL SOCKS FOR PAVEMENT, ETC.) 11. FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100) FEET FROM NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE WAY OR MANMADE DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL SPILL TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. 12. CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE SANITATION UNITS (CONSTRUCTION TOILETS) SHALL BE LOCATED AT LEAST FIFTY (50) FEET FROM ANY STORMWATER INLET, WETLAND, OR DRAINAGE WAY. SAID FACILITIES MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND CONSTRUCTION TOILETS SHALL BE STAKED DOWN. 13. THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH THE CITY'S CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN WINDS ARE OF SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH, IN THE INSPECTOR'S OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND WELFARE. 14. WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER MONTHS) INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS WILL BE TREATED WITH MULCH AND MULCH TACKIFIER OR OTHER MATERIALS APPROVED BY EROSION CONTROL STAFF TO PREVENT EROSION. 15. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING, REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION METHODS. 17. SLOPE PROTECTION SHALL BE PROVIDED FOR DISTURBED AREAS STEEPER THAN 6:1. SLOPE PROTECTION CAN BE ACCOMPLISHED THROUGH SLOPE TERRACING USING A TRACKED VEHICLE, WINDROWING, HYDROMULCHING, EROSION CONTROL FABRIC, OR ANY METHOD AS APPROVED BY THE ENGINEER OR INSPECTOR. EROSION CONTROL NOTES: INLET PROTECTION IP VEHICLE TRACKING CONTROL PAD VTC TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION Project: LANDMARK APARTMENTS EXPANSION CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING BEST MANAGEMENT PRACTICES (BMPS) STRUCTURAL "INSTALLATION" Silt Fence Barriers * Flow Barriers (Wattles) * Inlet Filter Bags * Vegetative Temporary Seeding Planting Mulching / Sealant Permanent Seeding Planting Sod Installation Rolled Products : Netting / Blankets / Mats Contour Furrows (Ripping / Disking) Rock Bags * UTILITIES INSTALLATION FLAT WORK INSTALLATION VERTICAL INSTALLATION LANDSCAPE DEMOBILIZATION Vehicle Tracking Pad * * All Temporary BMPs to be Removed once Construction is Complete Any prior inlets that could use protecting Any prior inlets that could use protecting Anytime the site will sit dormant longer than 30 Days Anytime the site will sit dormant longer than 30 Days Anytime the site will sit dormant longer than 30 Days EXISTING DRAINAGE DITCH (DITCH C) WATER QUALITY POND D 2.09 ac. A1 1.98 ac. D1 0.06 ac. D2 0.69 ac. B1 2.22 ac. A2 0.45 ac. B2 0.62 ac. A3 1.22 ac. B6 0.48 ac. B5 0.29 ac. B4 3.14 ac. B3 0.46 ac. C1 0.16 ac. C2 0.33 ac. B10 0.07 ac. B7 0.01 ac. B8 0.16 ac. B9 0.47 ac. OS3 3.38 ac. E1 1.38 ac. E2 0.48 ac. OS1 1.80 ac. OS2 0.18 ac. F2 0.04 ac. F1 a3 d1 a1 b1 b2 b4 a2 ? b5 b7 ? b9 b10 b3 c1 d2 os2 os3 e1 e2 os1 b8 c2 CITY OF FORT COLLINS 100-YR FLOODWAY S SHIELDS ST. HOBBIT ST. WALLENBERG DR. FEMA 100-YR HIGH RISK FLOOD FRINGE CITY OF FORT COLLINS 100-YR FLOODPLAIN EXISTING SPRING CREEK TRAIL SPRING CREEK EXISTING SIDEWALK EXISTING 8' TRAIL CANAL IMPORTATION WINNE GRANT R/JOHNELLE S 1821 WALLENBERG DR ERIKSEN CHRISTOPHER M 1825 WALLENBERG DR MCCOY JOHN H/SHERRY P 1900 S SHIELDS ST HILL POND CONDOMINIUMS SPRING CREEK FEMA FLOODWAY f2 f1 PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED OUTFALL PIPE PROPOSED STORM DRAIN PROPOSED OUTLET STRUCTURE INTERMILL LAND SURVEYING, INC. NORTHERN ENGINEERING SERVICES, INC. COMPANY PROJECT NO. P-11-6963 COMPANY PROJECT NO. 838-016 DATE: APRIL 2011 DATE: JULY 2015 KING SURVEYORS COMPANY PROJECT NO. 20190806 DATE: JANUARY 2020 PROJECT DATUM: NAVD88 BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL. ELEVATION: 5025.67 BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER AVENUE, ON A WATER VALVE PIT. ELEVATION: 5010.65 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'. BASIS OF BEARINGS WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01' 50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING. Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 1 1 NOTES: 1. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION 2. ALL ELEVATIONS DEPICTED IN PLAN VIEW AND BENCHMARKS LISTED HEREON ARE PER THE CITY OF FORT COLLINS VERTICAL CONTROL DATUM (NAVD 88). 3. ANY ITEMS LOCATED IN THE FLOODWAY THAT CAN FLOAT (E.G., PICNIC TABLES, BIKE RACKS, ETC.) MUST BE ANCHORED. 4. NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT. LANDSCAPING SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE FLOODWAY. 5. REFER TO THE PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT FOR THE QUARRY BY WATERMARK, DATED NOVEMBER 10, 2020 BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. 6. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, REMODELING OF EXISTING STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE 100YEAR FLOODPLAIN LIMITS. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. A LEGEND: NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 DR1 DRAINAGE PLAN 16 KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST CROSS-SECTION (CSL) XS#: 2446 FIELD SURVEY BY: CORRECTED EFFECTIVE BASE FLOOD ELEVATION (BFE) ELEVATION NAVD 88 5003 (NAVD88) BENCHMARK FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner H-B2 0.74 ac. H-C1 0.16 ac. h-a2 H-A2 0.17 ac. H-D1 os2 os3 1.80 ac. OS2 0.47 ac. OS3 0.44 ac. H-B3 h-b3 h-c2 5.47 ac. H-C2 3.38 ac. H-E1 1.38 ac. H-E2 h-e1 h-e2 0.48 ac. OS1 os1 0.04 ac. H-F1 h-f1 h-f2 0.18 ac. H-F2 S SHIELDS ST. HOBBIT ST. WALLENBERG DR. FEMA 100-YR HIGH RISK FLOOD FRINGE CITY OF FORT COLLINS 100-YR FLOODPLAIN EXISTING SPRING CREEK TRAIL SPRING CREEK EXISTING SIDEWALK EXISTING 8' TRAIL CANAL IMPORTATION WINNE GRANT R/JOHNELLE S 1821 WALLENBERG DR ERIKSEN CHRISTOPHER M 1825 WALLENBERG DR MCCOY JOHN H/SHERRY P 1900 S SHIELDS ST HILL POND CONDOMINIUMS Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 LEGEND: NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 H1 PLAN HISTORIC DRAINAGE 15 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST INTERMILL LAND SURVEYING, INC. NORTHERN ENGINEERING SERVICES, INC. COMPANY PROJECT NO. P-11-6963 COMPANY PROJECT NO. 838-016 DATE: APRIL 2011 DATE: JULY 2015 KING SURVEYORS COMPANY PROJECT NO. 20190806 DATE: JANUARY 2020 PROJECT DATUM: NAVD88 BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL. ELEVATION: 5025.67 BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER AVENUE, ON A WATER VALVE PIT. ELEVATION: 5010.65 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'. BASIS OF BEARINGS WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01' 50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING. PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 1 1 NOTES: 1. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION 2. ALL ELEVATIONS DEPICTED IN PLAN VIEW AND BENCHMARKS LISTED HEREON ARE PER THE CITY OF FORT COLLINS VERTICAL CONTROL DATUM (NAVD 88). 3. ANY ITEMS LOCATED IN THE FLOODWAY THAT CAN FLOAT (E.G., PICNIC TABLES, BIKE RACKS, ETC.) MUST BE ANCHORED. 4. NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT. LANDSCAPING SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE FLOODWAY. 5. REFER TO THE PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT FOR THE QUARRY BY WATERMARK, DATED NOVEMBER 10, 2020 BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. 6. THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, REMODELING OF EXISTING STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE 100YEAR FLOODPLAIN LIMITS. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. A CROSS-SECTION (CSL) XS#: 2446 FIELD SURVEY BY: CORRECTED EFFECTIVE BASE FLOOD ELEVATION (BFE) ELEVATION NAVD 88 5003 (NAVD88) BENCHMARK FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R AREA DRAIN PROPOSED RAIN GARDEN SPRING CREEK TRACT B EXISTING 8' TRAIL RAIN GARDEN BIOMEDIA AREA PROPOSED 4' SIDEWALK CULVERT CANAL IMPORTATION TRACT A NATURAL AREA BUFFER LOT 1 Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 G4 GRADING PLAN 14 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET 2.0% (47.45) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LEGEND: PROPOSED GRADE BREAK KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST G1 G2 G3 G4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET G2 SEE SHEET G3 2.1% 0.6% 1.9% 2.0% 1.6% 0.5% 2.0% 2.0% PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED OUTFALL PIPE PROPOSED 2' CONCRETE PAN PROPOSED AREA DRAIN EXISTING 26" STORM DRAIN EXISTING 30" STORM DRAIN PROPOSED OUTLET STRUCTURE S SHIELDS ST LOT 2 LOT 1 SPRING CREEK PROPOSED 4' SIDEWALK CULVERT EXISTING SPRING CREEK TRAIL EXISTING SIDEWALK EXISTING SIDEWALK TRACT B 6' SIDEWALK 0.6% NATURAL AREA BUFFER LOT 1 PROPOSED SIDEWALK CHASE KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 G3 GRADING PLAN 13 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET 2.0% (47.45) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LEGEND: PROPOSED GRADE BREAK G1 G2 G3 G4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET G1 SEE SHEET G4 X X X X X X X X X X X X X X X X WINNE GRANT R/JOHNELLE S 1821 WALLENBERG DR 9' SIDEWALK 6' SIDEWALK 9' SIDEWALK 9' SIDEWALK 9' SIDEWALK 6' SIDEWALK 6' SIDEWALK 7' SIDEWALK 7' SIDEWALK 6' SIDEWALK 5' SIDEWALK 5' SIDEWALK 7' SIDEWALK 6' SIDEWALK UD UD UD UD UD UD UD 14.03 13.19 15.03 14.50 15.24 13.88 15.09 13.10 12.18 14.25 13.94 13.89 13.33 13.76 13.73 14.24 13.76 13.03 12.84 12.70 12.56 12.47 12.07 11.55 12.43 13.62 13.13 13.18 13.66 12.45 14.09 15.00 14.63 13.86 13.93 14.51 15.15 15.20 14.54 12.45 12.49 12.82 12.47 12.08 12.54 13.39 12.93 13.48 14.70 14.64 14.62 12.37 12.47 13.26 13.20 13.39 13.08 12.74 FFE=16.33 FFE=14.75 FFE=14.40 FFE=14.40 FFE=14.75 FFE=14.75 FFE=14.00 FFE=14.00 FFE=13.66 FFE=13.66 FFE=14.25 FFE=14.25 FFE=14.99 14.09 14.09 14.09 14.09 15.66 15.66 16.00 16.00 14.32 14.32 14.32 14.32 13.58 13.00 13.00 13.33 13.33 13.73 13.72 14.08 14.08 4' SIDEWALK 4' SIDEWALK 5' SIDEWALK 2.0% 1.5% 0.5% 2.0% 0.6% 1.5% 0.5% 1.1% 2.0% 2.0% 0.5% 2.0% 2.0% 0.5% 0.5% 0.5% 1.7% 2.0% 2.0% 0.9% 1.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.1% 0.5% 0.5% 0.5% 0.5% 0.5% 1.0% 0.5% 1.0% PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED AREA DRAIN PROPOSED AREA DRAIN 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 5' SIDEWALK 4' SIDEWALK PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN 26' EMERGENCY ACCESS EASEMENT TRACT A LOT 1 EXISTING 8' TRAIL RAIN GARDEN BIOMEDIA AREA PROPOSED 4' SIDEWALK CULVERT 33' WATER EASEMENT (13.73) (13.21) CANAL IMPORTATION HOBBIT ST WALLENBERG DR PROPOSED STORM DRAIN 0.5% NATURAL AREA BUFFER NATURAL AREA BUFFER 13.22 0.5% LOT 1 LOT 1 LOT 1 48' SANITARY SEWER EASEMENT KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 G2 GRADING PLAN 12 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET 2.0% (47.45) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LEGEND: PROPOSED GRADE BREAK G1 G2 G3 G4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET G4 SEE SHEET G1 16.00 15.62 15.54 15.24 13.88 15.09 16.32 16.01 16.81 17.26 17.74 17.99 16.90 17.10 16.27 16.07 15.22 15.15 14.09 17.38 16.79 16.41 15.62 14.72 14.58 15.00 14.63 13.86 13.93 14.51 15.15 15.20 14.54 15.38 15.54 15.58 16.12 16.17 16.51 17.82 17.01 16.92 15.97 16.80 17.21 16.74 17.46 13.26 13.20 13.39 FFE=16.25 FFE=16.33 FFE=19.00 FFE=18.50 FFE=16.50 FFE=17.73 18.06 15.66 15.66 15.66 15.66 15.75 15.75 15.75 15.75 17.83 17.83 17.83 17.83 FFE=18.50 18.50 18.50 18.50 18.50 17.23 17.73 17.73 17.73 18.00 18.00 18.50 18.00 16.00 16.00 16.00 16.00 17.73 2.0% 3.0% 4.0% 2.0% 1.0% 0.8% 0.8% 2.0% 2.0% 2.0% 0.8% 2.0% 0.8% 2.0% 0.6% 1.5% 0.8% 1.8% 1.8% 2.0% 2.0% 1.1% 1.0% 2.0% 0.5% 1.7% 1.8% 2.0% 0.8% 0.5% 0.5% 2.0% 2.0% 2.0% 2.0% 0.5% 0.5% 2.0% 2.0% 2.0% 2.0% 1.5% 0.5% 2.0% 0.6% 2.0% 2.5% 2.0% 1.1% 2.1% 1.2% 3.0% 3.2% 2.0% 1.5% 0.5% 0.5% 0.5% 1.0% 1.5% 1.0% 1.3% 1.2% PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED STORM DRAIN PROPOSED 2' CONCRETE PAN PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' CONCRETE PAN PROPOSED AREA DRAIN PROPOSED AREA DRAIN PROPOSED AREA DRAIN PROPOSED AREA DRAIN PROPOSED AREA DRAIN PROPOSED AREA DRAIN PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED AREA DRAIN PROPOSED AREA DRAIN PROPOSED AREA DRAIN PROPOSED AREA DRAIN PROPOSED AREA DRAIN 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 33' WATER EASEMENT 48' SANITARY SEWER EASEMENT LOT 1 LOT 1 EXISTING SIDEWALK (13.73) 5' SIDEWALK EXISTING SIDEWALK HOBBIT ST PROPOSED 30" VERTICAL CURB & GUTTER 2.0% 0.6% LOT 1 LOT 1 Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 G1 GRADING PLAN 11 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET 2.0% (47.45) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LEGEND: PROPOSED GRADE BREAK KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST G1 G2 G3 G4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET G3 SEE SHEET G2 X X X X X X X X X X X X X X ST ST ST ST ST ST ST ST WINNE GRANT R/JOHNELLE S 1821 WALLENBERG DR ERIKSEN CHRISTOPHER M 1825 WALLENBERG DR MCCOY JOHN H/SHERRY P 1900 S SHIELDS ST HILL POND CONDOMINIUMS UD UD UD UD S SHIELDS ST. HOBBIT ST. WALLENBERG DR. FEMA 100-YR HIGH RISK FLOOD FRINGE CITY OF FORT COLLINS 100-YR FLOODPLAIN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 6' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN EXISTING SPRING CREEK TRAIL PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED OUTFALL PIPE PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED STORM DRAIN PROPOSED RAIN GARDEN PROPOSED RAIN GARDEN PROPOSED OUTLET STRUCTURE PROPOSED DRAINAGE EASEMENT PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE LOT 1 TRACT B TRACT A LOT 2 SPRING CREEK RAIN GARDEN BIOMEDIA AREA RAIN GARDEN BIOMEDIA AREA PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' SIDEWALK CULVERT PROPOSED SIDEWALK CULVERT PROPOSED SIDEWALK CULVERT EXISTING SIDEWALK EXISTING 8' TRAIL PROPOSED LANDSCAPE WALL CANAL IMPORTATION KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 OG1 OVERALL GRADING PLAN 10 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET 2.0% (47.45) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LEGEND: PROPOSED GRADE BREAK City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner G1 G2 G3 G4 HIGH RISK FLOOD FRINGE CITY OF FORT COLLINS 100-YR FLOODPLAIN NATURAL AREA BUFFER PROPOSED 4' SIDEWALK CULVERT CANAL IMPORTATION LOT 1 FEMA 100-YR TRACT A HIGH RISK FLOOD FRINGE NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10. ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. EXISTING LOT LINE EASEMENT LINE PROPOSED SEWER SERVICE S PROPOSED WATER SERVICE W EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 U4 UTILITY PLAN 9 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST U1 U2 U3 U4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET U2 SEE SHEET U3 30" W 36" W 36" W 36" W 36" W 36" W 8" W 8" W D F.O. D S H2O ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ST ST ST ST ST ST ST ST ST ST ST ST SS SS SS ST HILL POND CONDOMINIUMS EXISTING 36" WATERLINE 6' SIDEWALK 6' SIDEWALK S S W F W W F S PROPOSED 8" PVC SANITARY SEWER PROPOSED 8" PVC WATER S SHIELDS ST. 6' SIDEWALK 26' FL-FL 60' FL-FL PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED 2' CONCRETE CHASE 26' EMERGENCY ACCESS EASEMENT EXISTING 26" STORM DRAIN EXISTING 30" STORM DRAIN EXISTING SPRING CREEK TRAIL PROPOSED FIRE HYDRANT PROPOSED 8" PVC SANITARY SEWER SPRING CREEK PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' SIDEWALK CULVERT LOT 2 LOT 1 NATURAL AREA BUFFER EXISTING 8" WATERLINE EXISTING 30" WATERLINE EXISTING SIDEWALK PROPOSED SANITARY SERVICE (TYP.) LOT 1 TRACT B FEMA 100-YR HIGH RISK FLOOD FRINGE CONNECT TO EXISTING WATERLINE EXISTING 18" CLAY SANITARY SEWER NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10. ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. EXISTING LOT LINE EASEMENT LINE PROPOSED SEWER SERVICE S PROPOSED WATER SERVICE W EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 U3 UTILITY PLAN 8 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST U1 U2 U3 U4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET U1 SEE SHEET U4 UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD S H Y D MH S H Y D MM M H 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X X X X X X X X X X X X X X X X X X X X X SS SS 30" W 30" W WINNE GRANT R/JOHNELLE S 1821 WALLENBERG DR 9' SIDEWALK 6' SIDEWALK 9' SIDEWALK 9' SIDEWALK 9' SIDEWALK 6' SIDEWALK 6' SIDEWALK 7' SIDEWALK 6' SIDEWALK 5' SIDEWALK 5' SIDEWALK 7' SIDEWALK 6' SIDEWALK S S S S S S S S S S S S S W W W W W W W W W W F F F F F F F F F F F UD UD W F UD UD UD UD UD F W PROPOSED 8" PVC SANITARY SEWER PROPOSED 8" PVC WATER PROPOSED 8" PVC SANITARY SEWER WALLENBERG DR. PROPOSED SANITARY SERVICE (TYP.) PROPOSED FIRE SERVICE (TYP.) PROPOSED WATER SERVICE (TYP.) CONNECT TO EXISTING 24" SANITARY SEWER 26' FL-FL 23' FL-FL 26' FL-FL 26' FL-FL 6' SIDEWALK 6' SIDEWALK 4' SIDEWALK 4' SIDEWALK 26' FL-FL PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED RAIN GARDEN PROPOSED STORM DRAIN PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT 7' SIDEWALK PROPOSED RAIN GARDEN 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 5' SIDEWALK 4' SIDEWALK 33' WATERLINE EASEMENT PROPOSED 8" PVC WATER RAIN GARDEN BIOMEDIA AREA PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' SIDEWALK CULVERT EXISTING 8' TRAIL TRACT A FEMA 100-YR HIGH RISK FLOOD FRINGE CITY OF FORT COLLINS 100-YR FLOODPLAIN NATURAL AREA BUFFER EXISTING 8" PVC WATER EXISTING UNDERDRAIN CANAL IMPORTATION CANAL IMPORTATION PROPOSED 8" PVC WATER CONNECT TO EXISTING WATERLINE PROPOSED 8" PVC WATER LOT 1 LOT 1 CONNECT TO EXISTING SANITARY SEWER MANHOLE EXISTING FH EXISTING FH EXISTING 30" WATERLINE CONNECT TO EXISTING WATERLINE CONNECT TO EXISTING WATERLINE NATURAL AREA BUFFER 5' SIDEWALK NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10. ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. EXISTING LOT LINE EASEMENT LINE PROPOSED SEWER SERVICE S PROPOSED WATER SERVICE W EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 U2 UTILITY PLAN 7 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST U1 U2 U3 U4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET U4 SEE SHEET U1 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T G G G G G G G G G G G G G G G G G G G G G W W E W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W W E E E E E E E 15" SS 30" W 36" W 36" W 36" W 36" W W W W UD UD UD UD W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W EXISTING 8" WATERLINE EXISTING 18" CLAY SANITARY SEWER EXISTING 12" WATERLINE EXISTING 12" WATERLINE EXISTING 36" WATERLINE EXISTING ELECTRIC VAULT (TYP.) 30' HALF ROW 6' SIDEWALK 5' SIDEWALK 6' SIDEWALK 6.5' SIDEWALK 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK 9' SIDEWALK 9' SIDEWALK 8' SIDEWALK 6' SIDEWALK 4.5' SIDEWALK S SHIELDS ST. HOBBIT ST. 4.5' SIDEWALK 5' SIDEWALK 9' SIDEWALK EXISTING 8" PVC SANITARY SEWER S S S S S S S W W W W W F W F F F F F F W F W S PROPOSED 8" PVC WATER EXISTING 15" SANITARY SEWER PROPOSED SANITARY SERVICE (TYP.) PROPOSED 8" PVC SANITARY SEWER PROPOSED FIRE SERVICE (TYP.) PROPOSED WATER SERVICE (TYP.) 26' FL-FL 23' FL-FL 6' SIDEWALK 26' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL EXISTING 30" WATERLINE PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN EXISTING 24" CLAY SANITARY SEWER 6' SIDEWALK PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 33' WATERLINE EASEMENT PROPOSED FIRE HYDRANT PROPOSED 8" PVC SANITARY SEWER PROPOSED 8" PVC WATER EXISTING SIDEWALK LOT 1 LOT 1 PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT EXISTING 8" PVC WATER EXISTING UNDERDRAIN EXISTING FIRE HYDRANT EXISTING SERVICES CONNECT TO EXISTING SANITARY SEWER MANHOLE CONNECT TO EXISTING WATERLINE 5' SIDEWALK NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10. ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. EXISTING LOT LINE EASEMENT LINE PROPOSED SEWER SERVICE S PROPOSED WATER SERVICE W EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 U1 UTILITY PLAN 6 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST U1 U2 U3 U4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET U3 SEE SHEET U2 IRR H Y D S S 15" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 8" SS 8" SS 8" SS 8" SS / / / / / / / / E E E E E E E E E E T T T T T T T T G G G G G G G G G G G W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W E FO E E E E E E E E E G G G G G G X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 36" W 36" W 36" W 8" W FDC F S UD E E E E E UD UD UD UD UD UD UD UD UD UD UD UD UD SS SS W W W S S UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD D F.O. D S H2O S H Y D MH S H Y D MM M H ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X X X X X X X X X X X X ST ST ST ST ST SS 30" W UD UD UD UD S SHIELDS ST. HOBBIT ST. WALLENBERG DR. FEMA 100-YR HIGH RISK FLOOD FRINGE EXISTING 21" CLAY SANITARY SEWER EXISTING 18" CLAY SANITARY SEWER PROPOSED 8" PVC WATER PROPOSED 8" PVC SANITARY SEWER EXISTING 12" WATERLINE EXISTING WATERLINE EXISTING 12" WATERLINE EXISTING 36" WATERLINE EXISTING ELECTRIC VAULT (TYP.) EXISTING 8" PVC SANITARY SEWER EXISTING 15" SANITARY SEWER EXISTING UNDERDRAIN 4' SANITARY MANHOLE (TYP.) PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED 8" PVC SANITARY 33' WATERLINE EASEMENT 48' SANITARY SEWER EASEMENT PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED FIRE HYDRANT PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED OUTFALL PIPE PROPOSED STORM DRAIN PROPOSED OUTLET STRUCTURE RAIN GARDEN BIOMEDIA AREA RAIN GARDEN BIOMEDIA AREA SPRING CREEK EXISTING 8' TRAIL EXISTING SPRING CREEK TRAIL NATURAL AREA BUFFER LOT 1 TRACT B TRACT A LOT 2 PROPOSED FIRE HYDRANT PROPOSED 2' CURB CUT CANAL IMPORTATION CONNECT TO EXISTING WATER LINE CONNECT TO EXISTING WATER LINE CONNECT TO EXISTING WATER LINE CONNECT TO EXISTING WATER LINE EXISTING FIRE HYDRANT PROPOSED 8" PVC WATER EXISTING FIRE HYDRANT CONNECT TO EXISTING SANITARY CONNECT TO EXISTING SANITARY CONNECT TO EXISTING SANITARY EXISTING FIRE HYDRANT CONNECT TO CONNECT TO EXISTING SANITARY EXISTING SANITARY EXISTING 26" STORM EXISTING 30" STORM EXISTING 18" CLAY SANITARY SEWER Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 OU1 OVERALL UTILITY PLAN 5 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 60 0 60 Feet 60 120 180 NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITIES SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ALL WATERLINES SHALL HAVE A 4.5'-5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10. ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. EXISTING LOT LINE EASEMENT LINE PROPOSED SEWER SERVICE S PROPOSED WATER SERVICE W EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST U1 U2 U3 U4 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK 5' SIDEWALK 6' SIDEWALK 9' SIDEWALK 9' SIDEWALK 6' SIDEWALK 6' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 5' SIDEWALK 9' SIDEWALK 9' SIDEWALK 9' SIDEWALK 6' SIDEWALK 6' SIDEWALK 7' SIDEWALK 4' SIDEWALK 4' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 6' SIDEWALK S SHIELDS ST. HOBBIT ST. WALLENBERG DR. 8' SIDEWALK 6' SIDEWALK 6' SIDEWALK 7' SIDEWALK 6' SIDEWALK 4' SIDEWALK EXISTING 8' TRAIL SPRING CREEK EXISTING SPRING CREEK TRAIL EXISTING SIDEWALK LOT 1 TRACT B TRACT A LOT 2 CANAL IMPORTATION 8.5' 8.5' 8' 8' 8' 17' 9' 8' 9' 9' 8' 9' 8' 9' 9' 9' 9' 9' 9' 9' 9' 9' 8.5' 9' 8.5' 8.5' 8.5' 8' 8' 8.5' 8.5' 8.5' 8.5' 8.5' 5' 8' 8.5' 8.5' 8.5' 17' 17' 17' 17' 17' 17' 17' 8.5' 8.5' 17' 17' 21' 17' 8.5' 8.5' 17' 17' 17' 8.5' 17' 8.5' 17' 17' 17' 8.5' 8.5' 8.5' 8.5' 8.5' 17' 17' 17' 14' 17' 15.5' 15.5' 17' 17' 17' 8.5' 17' 8.5' 8.5' 8.5' 8.5' 17' 16.5' 16.5' 17' 9' 9' 26' FL-FL 23' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL 26' FL-FL 60' FL-FL 20' FL-FL PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 6' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN EXISTING SIDEWALK CULVERT FEMA 100-YR HIGH RISK FLOOD FRINGE CITY OF FORT COLLINS 100-YR FLOODPLAIN PROPOSED 4' SIDEWALK CULVERT RAIN GARDEN BIOMEDIA AREA RAIN GARDEN BIOMEDIA AREA PROPOSED 4' SIDEWALK CULVERT NATURAL AREA BUFFER PROPOSED 2' CONCRETE PAN PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' SIDEWALK CULVERT FEMA 100-YR HIGH RISK FLOOD FRINGE PROPOSED 2' CURB CUT PROPOSED SIDEWALK CULVERT NATURAL AREA BUFFER 21' 21' PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN MATCH INTO EXISTING SIDEWALK, CURB, AND GUTTER 26' FL-FL 33' WATER EASEMENT PROPOSED PEDESTRIAN BRIDGE Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 PV1 PAVING PLAN 4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 EASEMENTS NOTES: 1. SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2. PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION MANUAL. 3. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 4. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5. ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK. 6. REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. PROPOSED VERTICAL CURB & GUTTER PROPERTY BOUNDARY EXISTING LOT LINE PROPOSED EDGE OF PAVEMENT / / / / / / / / ASPHALT PAVING PROPOSED OUTFALL VERTICAL CURB & GUTTER LEGEND: CONCRETE PAVING KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner IRR CONTROL IRR H Y D S S 15" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 18" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS / / / / / / / / E E E E E E E E E E T T T T T T T T G G G G G G G G G G G W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W E FO E E E E E E E E E G G G G G G X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 36" W 36" W 36" W 8" W F DC F S E E E E UD UD UD UD UD UD UD UD UD UD UD SS W W W S S UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD D F.O. D S H2O S H Y D MH S H Y D M M MH ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X X X X X X X X X X X X ST ST ST ST ST SS 30" W WINNE GRANT R/JOHNELLE S 1821 WALLENBERG DR ERIKSEN CHRISTOPHER M 1825 WALLENBERG DR MCCOY JOHN H/SHERRY P 1900 S SHIELDS ST HILL POND CONDOMINIUMS EXISTING 8" WATERLINE EXISTING 24" CLAY SANITARY SEWER EXISTING 18" CLAY SANITARY SEWER EXISTING 8" SANITARY SEWER TO BE RELOCATED EXISTING 12" WATERLINE EXISTING 24" CLAY SANITARY SEWER EXISTING 30" WATERLINE FEMA 100-YR HIGH RISK FLOOD FRINGE LANDMARK APARTMENTS TREES TO BE REMOVED (TYP.) EXISTING SPRING CREEK TRAIL S SHIELDS ST. HOBBIT ST. CITY OF FORT COLLINS 100-YR FLOODPLAIN FEMA 100-YR HIGH RISK FLOOD FRINGE EXISTING UNDERDRAIN EXISTING 40' ROW EXISTING 40' ROW WALLENBERG DR. EXISTING 5' SIDEWALK 36' FL-FL EXISTING 8" WATERLINE EXISTING FENCE EXISTING12" WATERLINE 40' UTILITY EASEMENT TO BE VACATED 24' UTILITY & ACCESS EASEMENT TO BE VACATED 28' UTILITY & ACCESS EASEMENT TO BE VACATED 28' UTILITY EASEMENT TO BE VACATED 15' UTILITY EASEMENT TO BE VACATED 40' UTILITY EASEMENT TO BE VACATED 20' UTILITY EASEMENT TO BE VACATED 10' UTILITY EASEMENT TO BE VACATED 8' UTILITY EASEMENT TO BE VACATED 20' DRAINAGE EASEMENT TO BE VACATED 20' UTILITY & ACCESS EASEMENT TO BE VACATED 8' UTILITY EASEMENT TO BE VACATED 15' UTILITY EASEMENT TO BE VACATED 40' UTILITY EASEMENT TO BE VACATED 8' UTILITY EASEMENT TO BE VACATED 8' UTILITY EASEMENT TO BE VACATED DRAINAGE EASEMENT REC. NO. 20200015504 20' UTILITY EASEMENT TO BE VACATED 120' DRAINAGE EASEMENT TO BE VACATED REC. NO. 87043454 25' TEMPORARY CONSTRUCTION EASEMENT TO BE VACATED REC. NO. 90019873 80' DRAINAGE EASEMENT TO BE VACATED REC. NO. 87043454 15' SLOPE EASEMENT TO BE VACATED REC. NO. 90019873 28' UTILITY & ACCESS EASEMENT TO BE VACATED EXISTING 8" SANITARY SEWER TO BE RELOCATED EXISTING UNDERDRAIN 54' ROW TO BE VACATED EXISTING ELECTRIC VAULT (TYP.) EXISTING 8' TRAIL EXISTING CANAL IMPORTATION SPRING CREEK EASEMENT TO BE VACATED Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 EX1 DEMOLITION PLAN EXISTING CONDITIONS & 3 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 1 inch = ft. 60 0 60 Feet 60 120 180 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. EXISTING OVERHEAD UTILITY OHE Intermill Land Surveying, Inc. Northern Engineering Services, Inc. Company Project No. P-11-6963 Company Project No. 838-016 Date: April 2011 Date: July 2015 King Surveyors Company Project No. 20190806 Date: January 2020 Earth Engineering Consultants, LLC Geotechnical Exploration Report Shields Mixed Use Development South of Hobbit Street, East of South Shields Street. Fort Collins, CO. EEC Project No. 1152075 KEYMAP CABLE F.O. T E MH 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS 24" SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W U D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD MH / / / / / / / / / / / / / / / / / / / / / / / / 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W 30" W X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST facilities in the development. 19. All recommendations of the Preliminary Drainage and Erosion Control Report for The Quarry by Watermark, dated November 10, 2020 by Northern Engineering Services, Inc. shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the City of Fort collins. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL. ELEVATION: 5025.67 BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER AVENUE, ON A WATER VALVE PIT. ELEVATION: 5010.65 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'. BASIS OF BEARINGS WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01' 50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Portions of the property are within FEMA Floodplain Zone AE, Fort Collins designated Floodplain and Fort Collins designated floodway. A Floodplain Use Permit is required for any development within the floodplain. See Grading Plan for detailed notes concerning construction within the floodplain and floodway. 49. Approved Variances are listed as follows: CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner CS2 CONSTRUCTION NOTES GENERAL AND 2 Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 Fort Collins, Colorado 80521 (970) 221-4158 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 ENGINEER ING N O R T H E RN ENGINEER ING N O R T H E RN PLANNER/ LANDSCAPE ARCHITECT I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: PROJECT LOCATION VICINITY MAP NORTH DEVELOPER/APPLICANT SITE ENGINEER SURVEYOR ORIGINAL FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: PROJECT BENCHMARKS: SHEET INDEX THE QUARRY BY WATERMARK City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner GAS----------------- Xcel Energy----------------------------- Al Ermer (970) 225-7869 ELECTRIC-------- City of Fort Collins Light & Power-- Luke Unruh (970) 416-2724 CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0245 TELECOM.--------Qwest Local Network------------------ Bill Johnson (970) 377-6401 WATER------------ City of Fort Collins Utilities----------- Matt Simpson (970) 416-2754 WASTEWATER--City of Fort Collins Utilities----------- Matt Simpson (970) 416-2754 STORMWATER- City of Fort Collins Utilities----------- Matt Simpson (970) 416-2754 Earth Engineering Consultants, LLC. "GEOTECHNICAL EXPLORATION REPORT SHIELDS MIXED USE DEVELOPMENT SOUTH OF HOBBIT STREET, EAST OF SOUTH SHIELDS STREET" Soilogic Project No. 1152075 Date: August 21, 2015 PROJECT DATUM: NAVD88 BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT ROAD AND SHIELDS STREET, ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL. ELEVATION: 5025.67 BENCHMARK 28-92 SOUTHWEST CORNER OF WEST PROSPECT ROAD AND CENTER AVENUE, ON A WATER VALVE PIT. ELEVATION: 5010.65 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'. BASIS OF BEARINGS WEST LINE OF THE NORTHWEST QUARTER OF SECTION 23 AS BEARING NORTH 00° 01' 50" EAST (ASSUMED BEARING), AND MONUMENTED AS SHOWN ON DRAWING. 1 CS1 COVER SHEET 2 CS2 GENERAL & CONSTRUCTION NOTES 3 EX1 EXISTING CONDITIONS & DEMOLITION PLAN 4 PV1 PAVING PLAN 5 OU1 OVERALL UTILITY PLAN 6-9 U1-U4 UTILITY PLAN 10 OG1 OVERALL GRADING PLAN 11-14 G1-G4 GRADING PLAN 15 H1 HISTORIC DRAINAGE PLAN 16 DR1 DRAINAGE PLAN 17 EC1 EROSION CONTROL PLAN 18 EC2 EROSION CONTROL DETAILS CS1 COVER SHEET 1 Sheet THE QUARRY BY WATERMARK These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 18 TYPICAL SECTIONS BEING A REPLAT OF LOTS 1-5, TRACT "A", TRACT "B", ALABASTER COURT, COROMANDEL CIRCLE AND STUART STREET, PULSE P.U.D. FILING ONE, LOCATED IN THE NORTHWEST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Intermill Land Surveying, Inc. Northern Engineering Services, Inc. Company Project No. P-11-6963 Company Project No. 838-016 Date: April 2011 Date: July 2015 King Surveyors Company Project No. 20190806 Date: January 2020