Loading...
HomeMy WebLinkAboutEAST PARK DISTRICT MAINTENANCE FACILITY - MJA200003 - SUBMITTAL DOCUMENTS - ROUND 2 - SITE PLANPROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: ... NOV. 2020 MAJOR AMENDMENT SUBMITTAL EAST PARK SISTRICT MAINTENANCE FACILITY FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES OR 534-6700 Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development CITY OF FORT COLLINS FORT COLLINS, COLORADO EAST PARK DISTRICT MAINTENANCE FACILITY MAJOR AMENDMENT SUBMITTAL CK KF KF REVIEW SET NOT FOR CONSTRUCTION East Park District Maintenance Facility Major Amendment Submittal 2982 Environmental Drive Fort Collins, Colorado 80525 Schedule of Drawings C001 - Site Plan Cover Sheet LS101 - Overall Site Plan Legal Description Vicinity Map Scale NTS 1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT SS S S 36" SS 36" SS 36" SS 36" SS 36" SS 36" SS 36" SS 36" SS 36" SS 36" SS 36" SS BIKE PARKING FOR (10) BIKES -SEE DETAIL - A/LS101 TRASH/RECYCLING - SEE DETAIL - B/LS101 EDGE WETLAND AREA TOP OF BANK UD UD UD UD UD UD E E E E F W S X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X TF (17) ADDITIONAL STAFF PARKING TECHNICIAN STORAGE SHEDS LANSCAPE MATERIAL GANG MOW TRUCK W/ TRAILER LARGE MOWER TRIM MOW TRUCK W/ TRAILER TRIM MOW TRUCK W/ TRAILER TRIPLE AXEL TRAILER DUMP TRUCK BACKHOE TRIM MOWER SCISSOR LIFT & TRAILER PLAYGROUND TRAILER TOOL CAT DUMPSTER GRAPPLE SKIDSTEER CHIP TRUCK & CHIPPER 3-SIDED SHED TRIM MOWER RECYCLE BINS LANSCAPE MATERIAL TECHNICIAN TECHNICIAN TECHNICIAN SEASONAL SEASONAL SEASONAL CONCRETE SIDEWALK 6'-0" 7'-0" 6'-0" 13'-0" BUILDING REFER TO ARCH DRAWINGS DETENTION (3) ADDITIONAL STAFF PARKING PLOW BLADES SNOW BROOMS COMPACTING DUMPSTER PICNIC TABLE STORAGE PORTABLE BIKE RACKS FUELING CREW CHIEF TECHNICIAN FORESTRY DETENTION PROPOSED NATURAL HABITAT BUFFER ZONE PROPOSED NATURAL HABITAT BUFFER ZONE 100' WETLAND BUFFER 100' WETLAND BUFFER EDGE WETLAND AREA TOP OF BANK 100' WETLAND BUFFER TRASH/RECYCLING BIKE RACKS LIGHTING FENCING PARK PROPERTY BOUNDARY PROPOSED GRADING CONTOUR EXISTING CONTOUR EXISTING TREES LEGEND CONCRETE PAVING RE: CIVIL GRAVEL PARKING RE: CIVIL SQUEEGEE GRAVEL (COLOR TBD) ASPHALT PAVING RE: CIVIL X NOTES: 1. THIS PROPERTY IS LOCATED IN THE FEMA REGULATED, 500YEAR POUDRE RIVER FLOODPLAIN. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. 2. ESSENTIAL SERVICES CRITICAL FACILITIES AND AT RISK POPULATION CRITICAL FACILITIES ARE PROHIBITED IN THE 500YEAR FLOODPLAIN. SCALE: TRASH & RECYCLING NTS STANDARD CITY OF FORT COLLINS PARK DEPARTMENT RECEPTACLES B SCALE: BIKE RACK NTS INSTALL PER MANUFACTURERS SPECIFICATIONS A PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: ... NOV. 2020 MAJOR AMENDMENT SUBMITTAL EAST PARK SISTRICT MAINTENANCE FACILITY FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES OR 534-6700 Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development CITY OF FORT COLLINS FORT COLLINS, COLORADO EAST PARK DISTRICT MAINTENANCE FACILITY MAJOR AMENDMENT SUBMITTAL CK KF KF REVIEW SET NOT FOR CONSTRUCTION SCALE: 1"=30'-0" A OVERALL SITE PLAN OVERALL SITE PLAN LS101 1"=30'-0" COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 7. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 8. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 9. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 10. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 11. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS ASSOCIATION. THE PROPERTY OWNERS ASSOCIATION IS PESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 12. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 13. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 14. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY_ FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_ INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. OWNER'S CERTIFICATION THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNER'S OF THE REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. OWNER (SIGNED) DATE OWNER (SIGNED) DATE (STATE OF ) ( )SS (COUNTY OF ) SUBSCRIBED AND SWORN TO BE BEFORE THIS DAY OF 20 , BY WITNESS MY HAND AND OFFICIAL SEAL. NOTARY PUBLIC ADDRESS MY COMMISSION EXPIRES COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES DIRECTOR APPROVED BY THE CURRENT COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES DIRECTOR OF THE CITY OF FORT COLLINS, COLORADO, THIS OF , 20 . COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES DIRECTOR Land Use Table Existing Zoning Urban Estates Proposed Uses Business and Light Use Maintenance Facility Maximum Building Height Permitted 3 Stories Maximum Building Height Proposed 29'-4 1/2" Tall Gross Site Area 3.6 AC 156,816 SF Estimated Floor Area .14 AC 6,000 SF Floor Area Ratio .039 Public ROW .17 AC 7,547 SF Net Site Area 3.46 AC 150,718 SF Overall Land Use Data: Building Coverage (Appx) .14 AC 6,000 SF 4% Parking & Drives (Appx) .32 AC 13,878 SF 9% Public ROW .17 AC 7,547 SF 5% Open Space/Landscape Area 2.97 AC 129,391 SF 82% Active Recreational Use 0 AC 0 SF 0% Total 3.6 AC 156,816 SF 100% Parking Requirements: Ratios: 0.1/Person - 0.3/Person (Outdoor Recreation) Provided Off-Street (Recreational) 16 2 ADA Total 18 Bicycle Parking: Ratios: 1/2,000 SF (Min. 4) Required Provided Recreational 4 Fixed 4 Fixed 0 Enclosed 0 Enclosed Total 4 4 SITE PLAN NOTES Tract I, Bucking Horse Filing Two, City of Fort Collins, County of Larimer, State of Colorado SITE PLAN COVER SHEET C001 - SITE