Loading...
HomeMy WebLinkAboutMAGNOLIA DWELLINGS - PDP200018 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTPRELIMINARY DRAINAGE REPORT FOR 335 East Magnolia Street Prepared by: Highland Development Services 6355 Fairgrounds Ave, Suite 100 Windsor, Colorado 80550 Phone: 970.674.7550 Prepared for: Forge + Bow Dwellings 116 N. College Ave Fort Collins, CO 80524 November 4, 2020 Job Number 20-1021-00 Highland Development Services, Inc. 6355 Fairgrounds Avenue, Suite 100 | Windsor, CO 80550 | 970.674.7550 November 4, 2020 Mr. Matt Simpson Fort Collins Utilities 700 Wood Street Fort Collins, CO 80522 RE: Preliminary Drainage Report for 335 East Magnolia Street Dear Matt, We are pleased to submit for your review, the Preliminary Drainage Report for the 335 East Magnolia multi-family redevelopment project. This report describes the drainage design intent to be in accordance with the City of Fort Collins Stormwater Criteria Manual. We appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. Sincerely, Highland Development Services Dan T. Egger, EI Jason T. Claeys, P.E., LEED AP Page i TABLE OF CONTENTS Table of Contents ............................................................................................................................. i Engineer Certification ......................................................................................................................ii General Description and Location .................................................................................................. 1 Site Description and Location ...................................................................................................... 1 Site Soils ....................................................................................................................................... 1 Storm Drainage Criteria .................................................................................................................. 3 Hydrologic Criteria ....................................................................................................................... 3 Hydraulic Criteria ......................................................................................................................... 3 Drainage Basins ............................................................................................................................... 4 Drainage Facility Design .................................................................................................................. 5 Drainage Conveyance Design ...................................................................................................... 5 Low Impact Development ............................................................................................................... 6 Stormwater Pollution Prevention ................................................................................................... 8 Conclusions ..................................................................................................................................... 9 References .................................................................................................................................... 10 Appendix ....................................................................................................................................... 11 Appendix A – Site Descriptions, Characteristics, & References .................................................. A Appendix B – Rational Calculations ............................................................................................. B Appendix C – Low Impact Development Calculations ................................................................. C Page ii ENGINEER CERTIFICATION I hereby certify that this report (plan) for the preliminary drainage design of 335 East Magnolia Street was prepared by me (or under my direct supervision) in accordance with the provisions of the City of Fort Collins Stormwater Criteria Manual and Construction of Public and Private Improvements for the Responsible Parties thereof. I understand that the City of Fort Collins does not and shall not assume liability for drainage facilities designed by others. ________________________________________ Jason T. Claeys, PE Registered Professional Engineer State of Colorado No. 42122 Page 1 GENERAL DESCRIPTION AND LOCATION SITE DESCRIPTION AND LOCATION 335 E. Magnolia Street is located in the Southeast Quarter and Southwest Quarter of Section 12, Township 7 North, Range 69 West of the Sixth Principal Meridian, City of Fort Collins, County of Larimer, within the State of Colorado. The property is the west half of Lot 1, Block 144 of the original Fort Collins plat, dated January 16, 1873. The site is bounded by private residential lots to the west and east, the alleyway to the south, and Magnolia Street to the north. The project site totals approximately 0.22 acres and is currently a single-family residential lot. The existing structures include a single-family residential home and a garden shed. The site is located within the Old Town Drainage Basin, which provides standard water quality for the site. The site generally slopes from the southwest to the northeast. A 2 ft tall retaining wall lies approximately 50 ft north of the alley right-of-way and steps down from south to north. The site grade south of the wall is approximately 3.5% and is approximately 2.0% north of the wall. Storm runoff via overland flow is conveyed through the site to Magnolia Street. The existing site is approximately 24.1% impervious. No wetlands are located within the area of proposed development. Offsite drainage is also conveyed through the existing site. Approximately 0.58 acres of offsite drainage area is conveyed along the western property line. It is assumed that this offsite basin is 25.3% impervious. It is anticipated that the proposed improvements will adequately convey the offsite runoff to Magnolia Street as it has historically. The project site is located within FEMA Zone X, Area of minimal flood hazard, per FEMA Flood Insurance Rate Panel 08069C0979H, effective 5/2/2012. FEMA Firmette is included in Appendix A. The existing single-family building is proposed to be removed and the site redeveloped with a four-unit, multi-family residential building. The proposed redevelopment also includes alley improvements, a parking area with access from the alley, and associated pedestrian walkways. Low impact development techniques are proposed to provide the stormwater quality enhancement requirements. SITE SOILS The 335 E. Magnolia Street site consists primarily of Fort Collins loam and Satanta loam and are classified as Type C hydrologic group, respectively. According to USDA/Natural Resource Page 2 Conservation Group, Type C soils a have slow infiltration rate when thoroughly wet. These soils consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils also have a slow rate of water transmission. Per the “Geotechnical Subsurface Exploration, Proposed Multi-Family Residence”, prepared by Earth Engineering Company, Inc. dated May 19, 2020: “Brown to reddish brown sandy lean clay soils were encountered at the surface at the boring locations. The sandy lean clay soils encountered in the borings were medium stiff to very stiff in consistency and exhibited a low potential for swelling with variation in moisture content at current moisture/density conditions. The moderately plastic sandy lean clay soils were underlain by brown sand and gravel materials at a depth of approximately 12 and 16 feet below present site grades at borings B-1 and B-2, respectively. The essentially granular materials were very dense in consistency, contained cobbles and extended to the bottom of the borings at a depth of approximately 20 and 25½ feet below present site grades.” Groundwater was also observed during the subsurface soil exploration: “At the time of drilling, free water was observed at a depth of approximately 16 and 19 feet below present site grades in the borings completed on this property. Approximately 48 hours after drilling, free water was observed at a depth of approximately 14½ and 18 feet below present site grades at borings B-1 and B-2, respectively.” Page 3 STORM DRAINAGE CRITERIA This final drainage report was prepared to meet or exceed the City of Fort Collins Stormwater Criteria Manual. The Criteria Manual and amendments to the Urban Drainage Flood Control District’s (UDFCD) Drainage Criteria Manual (USDCM) Volumes 1, 2 and 3 were referenced as guidelines for this design. HYDROLOGIC CRITERIA The rational method was performed to calculate the peak runoff rates for each basin. Percent imperviousness and runoff coefficients were calculated for each basin using the surface characteristics of each basin. The time of concentration was calculated using City of Fort Collins initial time of concentration and the intensity was calculated using the corresponding storm rainfall depth and the City of Fort Collins’ Intensity-Duration-Frequency Curve. HYDRAULIC CRITERIA The final storm drainage system will be designed to convey the minor and major storm events through the combination of storm sewer pipes and drain pans/channels. The Autodesk Hydraflow will be used to analyze the drainage system on the site. Page 4 DRAINAGE BASINS The 335 East Magnolia Steet developed drainage basins are delineated by areas draining through the site. The site is broken into 3 main drainage systems: Drainage Basin D1: Drainage Basin D1 pertains to the improvements on the site, which has an approximate area of 0.20 acres and is approximately 63.6% impervious. The improvements include the entire condominium building and the sidewalk on the east side of the building, as well as the parking lot and bike shed. Drainage Basin D2: Drainage Basin D2 pertains to the improvements on the site, which has an approximate area of 0.02 acres and is approximately 52.8% impervious. This area consists of the landscaping and sidewalk on the west side of the proposed building that drains to the proposed channel on the west property line. Drainage Basin OS1: Drainage Basin OS1 pertains to the existing drainage that flows through the site from the lot to the west and the lots to the south that currently drain across the alleyway and onto the site. This drainage system has an approximate area of 0.58 acres and is approximately 25.3% impervious. Page 5 DRAINAGE FACILITY DESIGN DRAINAGE CONVEYANCE DESIGN Storm infrastructure to convey runoff will include drain pans/channels and storm sewer pipes. Stormwater detention is not required for the site because the increase to impervious area on the site is less than 5,000 square feet. Water quality treatment for 50% of the site is provided by the Udall Natural Area water treatment facility. The remaining treatment must be provided by Low Impact Development (LID) methods. Drainage Basin D1: Drainage Basin D1 pertains to the improvements on the site, which has an approximate area of 0.20 acres. The proposed improvements will utilize a system of roof drains, area inlets, and storm drains to convey drainage to the proposed LID facility and then outlet to an existing 12” clay storm pipe in Magnolia Street. Drainage Basin D2: Drainage Basin D2 pertains to the improvements on the site, which has an approximate area of 0.02 acres. This system will intercept drainage from the western portion of the proposed lot. The area consists of landscaping and a sidewalk and is not able to be conveyed to the Stormtech chambers. Instead, drainage will sheet flow to the proposed concrete channel that runs the entire length of the western property line and drains into Magnolia Street. Drainage Basin OS1: Drainage Basin OS1 pertains to the existing drainage that flows through the site. This system will intercept drainage from the lot to the west and the lots to the south that currently drain across the alleyway and onto the site. The proposed improvements will include a concrete channel that runs the entire length of the western property line and drains into Magnolia Street. Page 6 LOW IMPACT DEVELOPMENT The City of Fort Collins updated the Low Impact Development ordinance in 2016 (Ordinance No. 007, 2016) to require: • Treat at least 75% of any newly developed or redeveloped impervious area using one or a combination of LID techniques, or • Treat at least 50% of any newly developed or redeveloped impervious area using one or a combination of LID techniques when 25% of private driveable surfaces are permeable. To satisfy the required implementation of Low Impact Development (LID) techniques, below grade filtration chambers (such as ADS StormTech chamber system) are proposed to be utilized. For the purposes of water quality, all chambers will be isolator rows with filter fabric placed along the bottom of all the chambers. Other LID techniques were explored, but due to the limited space available on-site filtration chambers were the most feasible means for additional water quality enhancement. Pavers within the parking area did not treat enough contributing area to justify their use. It is anticipated that the filtration chambers will include an impermeable liner due to the proximity to the proposed and neighboring structures. Sediment will be captured within the chambers prior to being released. The chambers will be accessible to remove sediments. Standard water quality is provided regionally off site. A Standard Operations Procedure will be provided at final design to assist in ensuring that these BMPs will adequately perform over time. Below is a description of the 4-step process for selecting structural BMPs: Urban Drainage and Flood Control District (UDFCD) recommends a Four Step Process for receiving water protection that focuses on reducing runoff volumes, treating the water quality capture volume (WQCV), stabilizing drainageways and implementing long-term source controls. The Four Step Process applies to the management of smaller, frequently occurring events. Step 1: Employ Runoff Reduction Practices To reduce runoff peaks, volumes, and pollutant loads from urbanizing areas, implement Low Impact Development (LID) strategies, including Minimizing Directly Connected Impervious Areas (MDCIA). Captured runoff from strategic areas are routed through below grade filtration chambers. Filtration chambers will slow and filter runoff prior to being released into the adjacent storm drain system. Page 7 Step 2: Implement BMPs that Provide a Water Quality Capture Volume with Slow Release The filtration chambers are designed to provide water quality capture volume per Urban Drainage’s recommendations and calculations. The captured runoff is designed for a 12-hr drain time. Step 3: Stabilize Drainageways Natural Drainageways are subject to bed and bank erosion due to increases in frequency, duration, rate and volume of runoff during and following development. Because the site will drain to an existing storm system, bank stabilization is unnecessary with this project. Step 4: Implement Site Specific and Other Source Control BMPs Proactively controlling pollutants at their source by preventing pollution rather than removing contaminants once they have entered the stormwater system or receiving waters is important when protecting storm systems and receiving waters. This can be accomplished through site specific needs such as construction site runoff control, post-construction runoff control and pollution prevention / good housekeeping. It will be the responsibility of the contractor to develop a procedural best management practice for the site. All calculations are attached for reference. Page 8 STORMWATER POLLUTION PREVENTION Erosion and sedimentation will be controlled on-site by use of sediment control logs, inlet protection, and a gravel construction entrance. The measures are designed to limit the overall sediment yield increase due to construction as required by the City of Fort Collins. During overlot and final grading the soil will be roughened and furrowed perpendicular to the prevailing winds. During the performance of the work required by these specifications or any operations appurtenant thereto, whether on right-of-way provided by the City or elsewhere, the contractor shall furnish all labor, equipment, materials, and means required. The Contractor shall carry out proper efficient measures wherever and as necessary to reduce dust nuisance, and to prevent dust nuisance that has originated from his operations from damaging crops, orchards, cultivated fields, and dwellings, or causing nuisance to persons. The Contractor will be held liable for any damage resulting from dust originating from his operations under these specifications on right-of-way or elsewhere. It is unlawful to track or cause to be tracked mud or other debris onto public streets or rights- of-way. Wherever construction vehicles access routes or intersect paved public roads, previsions must be made to minimize the transport of sediment by runoff or vehicles tracking onto the paved surface. Stabilized construction entrances are required with base material consisting of 6” coarse aggregate. The contractor will be responsible for clearing mud tracked onto public streets on a daily basis. All temporary and permanent erosion and sediment control practices must be maintained and repaired as needed to assure continued performance of their intended function. Maintenance is the responsibility of the contractor. All disturbed areas must be seeded and mulched within 30 days of project start. Vegetation shall not be considered established until a ground cover is achieved which is demonstrated to be mature enough to control soil erosion to the satisfaction of the Town Inspector and to survive severe weather condition. Page 9 CONCLUSIONS This Preliminary Drainage Report for 335 East Magnolia Street has been prepared to comply with the stormwater criteria set by the City of Fort Collins. The proposed drainage system will be designed to convey the developed peak storm water runoff through the site to the existing storm system. Drainage conveyance systems will be designed to convey drainage to existing roadways and collect onsite drainage and treat it in accordance with LID before discharging it into the existing storm drain system. Additionally, the drainage system will improve existing offsite conditions and protect the proposed building and neighboring lots by establishing conveyance to Magnolia Street and Peterson Street. This preliminary drainage report anticipates the implementation of best management practices for erosion control, temporary and permanent, and on-site construction facilities. It can therefore be concluded that development of 335 East Magnolia Street will comply with the storm water jurisdictional criteria and the approved City of Fort Collins Stormwater Criteria Manual and will not adversely affect the adjacent properties, streets, storm drain system and/or detention/water quality facilities. Page 10 REFERENCES 1. Urban Storm Drainage Criteria Manual (Volumes 1, 2, and 3), Urban Drainage and Flood Control District, June 2001, Revised January 2016. 2. Storm Drainage Criteria Manual and Construction Standards, City of Fort Collins Storm Water Utility, City of Fort Collins, Colorado, Updated January, 1997 with 2012 amendments. 3. Fort Collins Stormwater Criteria Manual, Fort Collins Utilities, City of Fort Collins, Colorado, Dated December 2018, Adopted January 2019. 4. “Hydrologic Group Rating for Larimer County Area, Colorado”, USDA-Natural Resources Conservation Service, National Cooperative Soil Survey. Web Soil Survey URL: http://websoilsurvey.nrcs.usda.gov. [9/28/2020] 5. “Geotechnical Subsurface Exploration, Proposed Multi-Family Residence 335 East Magnolia Street”, prepared by Earth Engineering Consultants, LLC, Dated May 19, 2020 6. “Flood Insurance Rate Map, Larimer County, Colorado – Map Number 08069C0979H”, Federal Emergency Management Agency, Map Revised May 2, 2012. Page 11 APPENDIX Appendix A – Site Descriptions, Characteristics, & References Appendix B – Rational Calculations Appendix C – Low Impact Development Calculations Appendix A APPENDIX A – SITE DESCRIPTIONS, CHARACTERISTICS, & REFERENCES PROJECT SITE PETERSON STREET E. MAGNOLIA STREET E. MULBERRY STREET WHEDBEE STREET MATHEWS STREET REMINGTON STREET OLIVE STREET Vicinity Map Scale: 1" = 250' PROJECT DATUM: NAVD 88 CITY OF FORT COLLINS BENCHMARK NO. 29-97: NORTHEAST CORNER OF MULBERRY ST. AND WHEDBEE ST., ON A CONCRETE TRAFFIC SIGNAL BASE ELEV = 4978.01 CITY OF FORT COLLINS BENCHMARK NO. 6-00: ON A CATCH BASIN AT THE NORTHWEST CORNER OF MULBERRY ST. AND COLLEGE AVE. ELEV = 4993.85 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR TO CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD 29 UNADJUSTED (PRIOR TO CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATIONS SHOULD BE USED: NGVD29 UNADJUSTED (PRIOR TO CITY OF FORT COLLINS DATUM) = 4978.01 (NAVD88 DATUM) - 3.18 NGVD29 UNADJUSTED (PRIOR TO CITY OF FORT COLLINS DATUM) = 4993.85 (NAVD88 DATUM) - 3.17 N W E S Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 9/28/2020 Page 1 of 4 4492380 4492390 4492400 4492410 4492420 4492430 4492440 4492450 4492380 4492390 4492400 4492410 4492420 4492430 4492440 4492450 493850 493860 493870 493880 493890 493900 493850 493860 493870 493880 493890 493900 40° 34' 58'' N 105° 4' 21'' W 40° 34' 58'' N 105° 4' 19'' W 40° 34' 55'' N 105° 4' 21'' W 40° 34' 55'' N 105° 4' 19'' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 15 30 60 90 Feet 0 5 10 20 30 Meters Map Scale: 1:390 if printed on A portrait (8.5" x 11") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A A/D B B/D C C/D D Not rated or not available Soil Rating Points A A/D B B/D C C/D D Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as Hydrologic Soil Group Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 35 Fort Collins loam, 0 to 3 percent slopes C 0.2 74.9% 94 Satanta loam, 0 to 1 percent slopes C 0.1 25.1% Totals for Area of Interest 0.2 100.0% Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 9/28/2020 Page 3 of 4 Component Percent Cutoff: None Specified Tie-break Rule: Higher Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 9/28/2020 Page 4 of 4 USGS The National Map: Orthoimagery. Data refreshed April 2020 National Flood Hazard Layer FIRMette 0 250 500 1,000 1,500 2,000 Feet Ü SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT SPECIAL FLOOD HAZARD AREAS Without Base Flood Elevation (BFE) Zone A, V, A99 With BFE or DepthZone AE, AO, AH, VE, AR Regulatory Floodway 0.2% Annual Chance Flood Hazard, Areas of 1% annual chance flood with average depth less than one foot or with drainage areas of less than one square mileZone X Future Conditions 1% Annual Chance Flood HazardZone X Area with Reduced Flood Risk due to Levee. See Notes.Zone X Area with Flood Risk due to LeveeZone D NO SCREENArea of Minimal Flood Hazard Zone X Area of Undetermined Flood HazardZone D Channel, Culvert, or Storm Sewer Levee, Dike, or Floodwall Cross Sections with 1% Annual Chance 17.5 Water Surface Elevation Coastal Transect Coastal Transect Baseline Profile Baseline Hydrographic Feature Base Flood Elevation Line (BFE) Effective LOMRs Limit of Study Jurisdiction Boundary Digital Data Available No Digital Data Available Unmapped This map complies with FEMA's standards for the use of digital flood maps if it is not void as described below. The basemap shown complies with FEMA's basemap accuracy standards The flood hazard information is derived directly from the authoritative NFHL web services provided by FEMA. This map was exported on 10/14/2020 at 11:26 AM and does not reflect changes or amendments subsequent to this date and time. The NFHL and effective information may change or become superseded by new data over time. This map image is void if the one or more of the following map elements do not appear: basemap imagery, flood zone labels, legend, scale bar, map creation date, community identifiers, FIRM panel number, and FIRM effective date. Map images for unmapped and unmodernized areas cannot be used for regulatory purposes. Legend OTHER AREAS OF FLOOD HAZARD OTHER AREAS GENERAL STRUCTURES Appendix B APPENDIX B – RATIONAL CALCULATIONS Design Engineer: Design Firm: Project Number: Date: % Impervious Runoff Coefficient C Return Period Frequency Adjustment Factor (Cf) 100% 0.95 2-year to 10-year 1.00 90% 0.95 100-year 1.25 90% 0.95 40% 0.50 0% 0.25 C2 to C10 C100 H1 9,492 0.218 0 1,376 321 1,911 5,884 24.1% 0.43 0.53 OS1 25,058 0.575 0 3,350 0 8,333 13,375 25.3% 0.43 0.53 D1 8,675 0.199 2,035 3,113 758 0 2,769 63.6% 0.73 0.91 D2 817 0.019 0 479 0 0 338 52.8% 0.66 0.83 D total 9,492 0.218 0 3,592 758 0 5,142 41.2% 0.57 0.71 Apaved COMPOSITE (sq feet) Aroof (sq feet) Awalk (sq feet) Agravel/pavers (sq feet) Alawn (sq feet) Lawns (Heavy, 2-7% Slope) Sub-basin Designation Atotal (sq feet) Atotal (acres) Weighted % Impervious Paved Roof Walks Runoff Coefficients and Frequency Adjustment Factors for City of Fort Collins - Storm Water Criteria Manual Gravel/Pavers % Impervious values from Table RO-11 in the Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual D.Egger 20-1021-00 November 4, 2020 Land Use 335 E. Magnolia Street DEVELOPED IMPERVIOUS AREA CALCULATION DESIGN CRITERIA: Design Engineer: Design Firm: Project Number: Date: EQUATIONS: -Equation 6-2 -Equation 6-4 -Urbanized Check Equation 6-5 - CoFC Overland Flow CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins Time of Concentration (2-yr to 10-yr) Type of Travel Surface Cv H1 H1 24.1% 0.43 0.218 74 0.0340 7.22 136 0.0200 Lawns 7 0.99 2.29 9.51 0.0249 15.62 9.51 OS1 OS1 25.3% 0.43 0.575 203 0.0250 13.22 189 0.0320 Paved Areas 20 3.58 0.88 14.10 0.0284 16.35 14.10 D1 D1 63.6% 0.73 0.199 58 0.0500 3.11 176 0.0100 Paved Areas 20 2.00 1.47 5.00 0.0199 9.47 5.00 D2 D2 52.8% 0.66 0.019 5 0.1000 0.85 121 0.0100 Paved Areas 20 2.00 1.01 5.00 0.0136 10.82 5.00 OVERALL SLOPE (ft/ft) tc (min) SLOPE (ft/ft) ti (min) LENGTH (ft) SLOPE (ft/ft) Table RO-2 VELOCITY (ft/s) LENGTH (ft) DESIGN CRITERIA: Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual Overland Flow Equations for City of Fort Collins - Storm Water Criteria Manual SUB-BASIN DATA INITIAL/OVERLAND TIME (ti) TRAVEL TIME (tt) tc =ti +tt (min) Urban Check Final tc (min) DESIGN POINT Sub-basin % Impervious C2-10 AREA (acres) tt (min) Design Engineer: Design Firm: Project Number: Date: EQUATIONS: -Equation 6-2 -Equation 6-4 -Urbanized Check Equation 6-5 - CoFC Overland Flow CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins Time of Concentration (100-yr) Type of Travel Surface Cv H1 H1 24.1% 0.53 0.218 74 0.0340 6.08 136 0.0200 Lawns 7 0.99 2.29 8.37 0.0249 15.62 8.37 OS1 OS1 25.3% 0.53 0.575 203 0.0250 11.12 189 0.0320 Paved Areas 20 3.58 0.88 12.00 0.0284 16.35 12.00 D1 D1 63.6% 0.91 0.199 58 0.0500 1.60 176 0.0100 Paved Areas 20 2.00 1.47 5.00 0.0199 9.47 5.00 D2 D2 52.8% 0.83 0.019 5 0.1000 0.53 121 0.0100 Paved Areas 20 2.00 1.01 5.00 0.0136 10.82 5.00 OVERALL SLOPE (ft/ft) tc (min) SLOPE (ft/ft) ti (min) LENGTH (ft) SLOPE (ft/ft) Table RO-2 VELOCITY (ft/s) LENGTH (ft) DESIGN CRITERIA: Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual Overland Flow Equations for City of Fort Collins - Storm Water Criteria Manual SUB-BASIN DATA INITIAL/OVERLAND TIME (ti) TRAVEL TIME (tt) tc =ti +tt (min) Urban Check Final tc (min) DESIGN POINT Sub-basin % Impervious C100 AREA (acres) tt (min) Design Engineer: Design Firm: Project Number: Date: EQUATIONS: I = rainfall intensity (in/hr) Q n = n -yr peak discharge (cfs) P 1 = one-hour point rainfall depth (in) C n = n -yr runoff coefficient t c = time of concentration (min) I n = n -yr rainfall intensity (in/hr) P 1-2yr = 0.82 in A n = Basin drainage area (ac) P 1-10yr = 1.40 in P 1-100yr = 2.86 in BASIN SUMMARY: tc (min) Runoff Coeff (C2-10) C(A) (acres) Intensity (in/hr) Q (ft3/s) tc (min) Runoff Coeff (C2-10) C(A) (acres) Intensity (in/hr) Q (ft3/s) tc (min) Runoff Coeff. (C100) C(A) (acres) Intensity (in/hr) Q (ft3/s) H1 H1 0.218 9.51 0.43 0.09 2.26 0.21 9.51 0.43 0.09 3.86 0.36 8.37 0.53 0.12 8.26 0.96 OS1 OS1 0.575 14.10 0.43 0.25 1.91 0.47 14.10 0.43 0.25 3.26 0.80 12.00 0.53 0.31 7.16 2.20 D1 D1 0.199 5.00 0.73 0.14 2.85 0.41 5.00 0.73 0.14 4.87 0.70 5.00 0.91 0.18 9.95 1.80 D2 D2 0.019 5.00 0.66 0.01 2.85 0.04 5.00 0.66 0.01 4.87 0.06 5.00 0.83 0.02 9.95 0.15 10-yr Peak Runoff 100-yr Peak Runoff 335 E. Magnolia Street DEVELOPED PEAK RUNOFF Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual DESIGN CRITERIA: Design Point Sub-basin Area (acres) D.Egger Highland Development Services 20-1021-00 October 15, 2019 2-yr Peak Runoff Q n = C n I n A n (0.786651) 1 ( 10 ) 28 . 5 t c P I + = 20-1021-00 Rational Calcs.xlsx Page 4 of 4 Highland Development Services Appendix C APPENDIX C – LOW IMPACT DEVELOPMENT CALCULATIONS Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA Low Impact Development Summary Sq-Ft Acres Impervious Area (sq-ft) % of Impervious Area Requiring Treatment Impervious Area Requiring Treatment 9,492 0.22 6,385 75% 4,789 LID Facility Contributing Basins Area Drainage to LID (sq-ft) % Impervious Impervious Area Treated (sq-ft) WQCV12-hr (watershed inches) WQCV12-hr (cu-ft) Treatment Method D1 D1 8,675 63.6% 5,906 0.20 144 Storm Chamber 4,789 5,906 123.3% Area (sq-ft) Area (acres) Treatment Ratio 8,675 0.20 91.4% 817 0.02 8.6% 9,492 0.22 335 E. Magnolia Street Low Impact Development Total % Required Treatment Development Area Breakdown City of Fort Collins - Ordinance No. 007, 2016 - Treat at least 75% of any newly developed or redeveloped impervious area using one or a combination of LID techniques, or - Treat at least 50% of any newly developed or redeveloped impervious area using one or a combination of LID techniques when 25% of private driveable surfaces are permeable. Impervious Area Treated (sq-ft) Impervious Area Required for LID Treatment (sq-ft) LID Treatment Summary LID Treatment Areas D.Egger Highland Development Services 20-1021-00 November 4, 2020 Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised January 2016) Description Total Redeveloped Area Allowed Filter Fabric Flow Rate a (cfs) 0.35 gpm/sq-ft SC-106LP 14 10 6 6 85.4 25 12 14.8 0.012 6.9 15.0 SC-310 18 8 6 6 85.4 34 16 20.2 0.016 14.7 31.0 SC-740 18 8 6 6 85.4 51 30 30.2 0.024 45.9 74.9 DC-780 18 12 6 9 85.4 51 30 30.2 0.024 46.2 78.4 MC-3500 24 8 12 9 90 77 45 48.1 0.038 109.9 178.9 14.9 46 MC-4500 24 7 12 9 52 100 60 36.1 0.028 106.5 162.6 35.7 108.7 LID Facility Chamber Type Total Release Rate f (cfs) WQ Flow g (cfs) Req'd Storage Volume h (cu-ft) Minimum No. of Chambers i Chamber Storage j (cu-ft) No. of Endcaps k Endcap Storage l (cu-ft) Total Chamber Volume m (cu-ft) Total Installed System Volume n (cu-ft) WQCV12-hr (cu-ft) D1 SC-310 0.07 0.21 62 4 62 12 0 62 205 144 Negligible Endcap Volume d (cu-ft) Min Installed Endcap/Aggregate Volume DESIGN CRITERIA 0.73 1.00 0.73 ft3 acre-ft 0.20 acres 62 0.00 0.07 cfs Time (min) 1/2 2-yr Intensity (I , in/hr) Q100 (cfs) Accumulative Runoff Volume (ft3) Accumulative Release Volume (ft3) Detained Volume (ft3) Detained Volume (acre-ft) 0 0.000 0.00 0 0 0 0.00 5 1.425 0.21 62 20 42 0.00 10 1.105 0.16 96 40 56 0.00 15 0.935 0.14 122 60 62 0.00 20 0.805 0.12 140 80 60 0.00 25 0.715 0.10 156 100 56 0.00 30 0.650 0.09 170 120 50 0.00 35 0.585 0.09 179 140 39 0.00 40 0.535 0.08 187 160 27 0.00 45 0.495 0.07 194 180 14 0.00 50 0.460 0.07 201 200 1 0.00 55 0.435 0.06 209 220 -11 0.00 60 0.410 0.06 215 240 -25 0.00 November 4, 2020 Design Engineer: Design Firm: Project Number: Date: 335 E. Magnolia Street WQ Treatment Volume - FAA Method D.Egger Highland Development Services 20-1021-00 Adjusted Runoff Coefficient (CC f ) Area (A ) Allowed Release Rate - City of Fort Collins - Storm Water Criteria Manual - City of Fort Collins accepts 1/2 of the 2-yr runoff as the WQ inflow rate WQ Treatment Volume Calculation - D1 Filtration Chamber Runoff Coefficient (C ) Frequency Factor (C f ) Required Detention User Inputs Chamber Model: SC-310 Outlet Control Structure: Yes Project Name: 335 E. Magnolia St Engineer: N/A Project Location: Measurement Type: Imperial Required Storage Volume: 144 cubic ft. Stone Porosity: 40% Stone Foundation Depth: 6 in. Stone Above Chambers: 6 in. Average Cover Over Chambers: 18 in. Design Constraint Dimensions: (15 ft. x 30 ft.) Results System Volume and Bed Size Installed Storage Volume: 205.05 cubic ft. Storage Volume Per Chamber: 14.70 cubic ft. Number Of Chambers Required: 4 Number Of End Caps Required: 4 Chamber Rows: 2 Maximum Length: 20.75 ft. Maximum Width: 8.77 ft. Approx. Bed Size Required: 181.90 square ft. System Components Amount Of Stone Required: 13.54 cubic yards Volume Of Excavation (Not Including Fill): 15.72 cubic yards e (cu-ft) Negligible Negligible Negligible Min Installed Chamber/Aggregate Volume c (cu-ft) 335 E. Magnolia Street Low Impact Development StormTech Chamber Configuration Summary StormTech Chamber Data Design Engineer: Design Firm: Project Number: Date: Length (in) Width (in) Height (in) Floor Area (sq-ft) Chamber Volume b (cu-ft) Min Aggregate Base (in) Min Aggregate Cover (in) Max Cover (ft) Min Cover (in) Chamber Model D.Egger Highland Development Services 20-1021-00 November 4, 2020 Note: a. Release rate per chamber, limited by flow through geotextile with accumulated sediment. City acceptable flow rates determined to be approximately 1/2 of the Nov-07 Qmax from Figure 17 of the "Final Report on Field Verification Testing of the StormTech Isoloator Row Treatement Unit", prepard by the University of New Hamphire Stormwater Center, dated Setpember 2010. b. Volume within chamber only, not accounting for void spaces in surrounding aggregate. c. Volume includes chamber and void spaces (40%) in surrounding aggregate, per chamber unit. d. Volume within endcap only, not accounting for void spaces in surrounding aggregate. e. Volume includes endcap and void spaces (40%) in surrounding aggregate, per chamber unit. f. Release rate per chamber times number of chambers. This is used as the allowed release rate for the FAA calculations. g. WQ flow, equal to 1/2 of the 2-yr peak runoff rate, referenced to size flow control structure. h. Required detention volume determined using the FAA Method based on the acceptable release rate of sediment accumulated filter fabric of the chambers and the 1/2 of the 2yr in flow rate. i. Number of chambers required to provide required FAA storage volume stored within the chamber and endcaps only (no aggregate storage). j. Total volume provided in chambers only (no aggregate storage). k. Number of endcaps based on desired chamber layout. Total Improvement Area Water Quality Area Treatment Summary Description Total Area Treated by LID Total Area unable to be Treated October 9, 2020 335 E. Magnolia Street DEVELOPED TIME OF CONCENTRATION D.Egger 20-1021-00 Highland Development Services t c = t i + t t 0 . 5 V = C v S w V L tt 60 = �� � 18 � 15� � � 60 24� � 12 � �� � 1.87�1.1 � �� �� � � � � 20-1021-00 Rational Calcs.xlsx Page 3 of 4 Highland Development Services October 9, 2020 335 E. Magnolia Street DEVELOPED TIME OF CONCENTRATION D.Egger 20-1021-00 Highland Development Services t c = t i + t t 0 . 5 V = C v S w V L tt 60 = �� � 18 � 15� � � 60 24� � 12 � �� � 1.87�1.1 � �� �� � � � � 20-1021-00 Rational Calcs.xlsx Page 2 of 4 Highland Development Services Fort Collins Amendments to the Urban Drainage and Flood Control District Criteria Manual BASINS: Highland Development Services 20-1021-00 Rational Calcs.xlsx Page 1 of 4 Highland Development Services OTHER FEATURES MAP PANELS 8 B 20.2 The pin displayed on the map is an approximate point selected by the user and does not represent an authoritative property location. 1:6,000 105°4'39"W 40°35'11"N 105°4'2"W 40°34'44"N PROJECT SITE E. MULBERRY ST. E. MAGNOLIA ST. PETERSON ST. of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 15, Jun 9, 2020 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Aug 11, 2018—Aug 12, 2018 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 9/28/2020 Page 2 of 4