HomeMy WebLinkAbout1605 PETERSON PLACE CARRIAGE HOUSE - FDP200023 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSPETERSON STREET
PETERS0N PLACE
SOUTH COLLEGE AVENUE
WEST PROSPECT ROAD
REMINGTON STREET
MATTHEW STREET
WEST LAKE STREET
UNIVERSITY OF ARTS
COLORADO STATE
COURT
PROSPECT
PETERSON STREET
PARKER STREET
EAST PROSPECT ROAD
EAST LAKE STREET
WHEDBEE STREET
PREPARED FOR:
JOB NUMBER
SHEET NUMBER
OF SHEETS
DATE SUBMITTED:
The engineer preparing these plans will not be responsible
for, or liable for, unauthorized changes to or uses of these
plans. All changes to the plans must be in writing and
must be approved by the preparer of these plans.
NO. BY DATE
CAUTION
REVISIONS:
VERTICAL:
HORIZONTAL:
SCALE
4025 Automation Way
Suite B2
Fort Collins, CO 80525
(970) 698-6046
CivilWorxeng.com
1605 PETERSON PLACE - CARRIAGE HOUSE
C20030
S. CORROUGH 10/14/2020
05
PRELIMINARY
NOT FOR
CONSTRUCTION
N
S
W E
PRELIMINARY ENGINEERING PLANS FOR
1605 PETERSON PLACE
LOT 3, BLOCK 1, GRAY-STRECKER SUBDIVISION
(PARCEL #9724210003, NW 1/4 OF SECTION 24, T07N, R69W)
VICINITY MAP
SCALE: 1" = 250'
OWNER / APPLICANT
CORROUGH SHANNON M TRUST
1605 PETERSON PL.
FORT COLLINS, CO 805251030
PHONE: (970) 212-6730
CONTACT: SHANNON CORROUGH
CIVIL ENGINEER
CIVILWORX, LLC
S89°57'20"W 149.00'
N89°57'20"E 149.00'
S00°02'40"E 75.00'
N00°02'40"W 75.00'
EXISTING FENCE LINES TO BE
REMOVED AS NECESSARY FOR
HOME CONSTRUCTION.
REMOVE PAVERS FOR
CONSTRUCTION, REPLACE AT
OWNERS PREFERENCE
FOLLOWING SANITARY
SERVICE INSTALLATION
REMOVE APPROX. 24 LF
OF EXISTING FENCING
AS NEEDED FOR DRIVEWAY
EXISTING PLANTER BOXES,
FENCES, TREES, AND SHRUBS TO
BE REMOVED (AND POTENTIALLY
REPLANTED) AS NECESSARY FOR
PROPOSED GRADING AND UTILITY
TRENCHES.
PREPARED FOR:
JOB NUMBER
SHEET NUMBER
OF SHEETS
DATE SUBMITTED:
The engineer preparing these plans will not be responsible
for, or liable for, unauthorized changes to or uses of these
plans. All changes to the plans must be in writing and
must be approved by the preparer of these plans.
NO. BY DATE
CAUTION
REVISIONS:
VERTICAL:
HORIZONTAL:
SCALE
4025 Automation Way
Suite B2
Fort Collins, CO 80525
(970) 698-6046
CivilWorxeng.com
1605 PETERSON PLACE - CARRIAGE HOUSE
C20030
S. CORROUGH 10/14/2020
05
PRELIMINARY
NOT FOR
CONSTRUCTION
0 10' 20'
SCALE: 1" = 10'
5'
EXISTING CONDITIONS
EX01
N/A
1" = 10'
XX
LEGEND
MAPPING / SITE
PROPERTY BOUNDARY
CURB AND GUTTER
EX-W
12.1%
EX-E
23.9%
0.9%
3.1%
1.5%
2.8%
3.4%
6.8%
2.1%
3.5%
16.4%
14.0%
2.5%
14.4%
0.9%
10.8%
0.9%
3.9%
6.2%
DP
DP
PREPARED FOR:
JOB NUMBER
SHEET NUMBER
OF SHEETS
DATE SUBMITTED:
The engineer preparing these plans will not be responsible
for, or liable for, unauthorized changes to or uses of these
plans. All changes to the plans must be in writing and
must be approved by the preparer of these plans.
NO. BY DATE
CAUTION
REVISIONS:
VERTICAL:
HORIZONTAL:
SCALE
4025 Automation Way
Suite B2
Fort Collins, CO 80525
(970) 698-6046
CivilWorxeng.com
1605 PETERSON PLACE - CARRIAGE HOUSE
C20030
S. CORROUGH 10/14/2020
05
PRELIMINARY
NOT FOR
CONSTRUCTION
0 10' 20'
SCALE: 1" = 10'
5'
EXISTING DRAINAGE MAP
EXDN01
N/A
1" = 10'
XX
NOTES
1. THE CONTRACTOR IS RESPONSIBLE FOR
ONE STORY
CARRIAGE
912.0 SF
EROSION PROTECTION
MEASURES TO REMAIN IN PLACE
UNTIL DISTURBED SOILS ARE
RE-VEGETATED OR LANDSCAPED
ROWS OF TALL NATIVE GRASSES
TO BE INSTALLED WITH FINAL
LANDSCAPING TO HELP WITH
STORMWATER FLOWS
PROPOSED DRAINAGE SWALE
PROPOSED SILT FENCE
ALL GUTTERS AND
DOWNSPOUTS TO DIRECT
FLOWS TOWARDS SWALE
23.5%
32.1%
9.5%
11.0%
5.0%
28.1%
NO WORK TO
SOUTH OF THIS
CONSTRUCTION
BOUNDARY
SOUTH LIMIT OF
CONSTRUCTION
PR-W
17.8%
PR-E
32.2%
DP
DP
6.4'
16.3'
10'
97.72
95.57
99.15
5' 5'
WD
SF
SF
SF
TOF=5001.06
97.01
96.02
98.29
98.51
26.9'
8'
8'
24.6%
7.4%
6.3%
12.5%
27.8%
30.0%
13.7%
3/4" WATER SERVICE
COPPER, MUNICIPEX, OR EQUIV.
PROPOSED 4" SANITARY SEWER SERVICE
SDR 35 PVC, OR EQUIVALENT
SLOPED AT 2.0% (MIN)
ONE STORY
CARRIAGE
912.0 SF
10'
6'
CONTRACTOR TO VERIFY
LOCATION OF EXISTING WATER
SERVICE LINE UPSTREAM FROM
THE VALVE, CUT IN 3/4" TEE
WITH CURB STOP ON NEW LINE
WYE INTO EXISTING
SANITARY LINE
CAUTION
UNDERGROUND ELECTRIC
CROSSING ANTICIPATED
CONTRACTOR TO REFRESH
LOCATES PRIOR TO
CONSTRUCTION
PREPARED FOR:
JOB NUMBER
SHEET NUMBER
OF SHEETS
DATE SUBMITTED:
The engineer preparing these plans will not be responsible
for, or liable for, unauthorized changes to or uses of these
plans. All changes to the plans must be in writing and
must be approved by the preparer of these plans.
NO. BY DATE
CAUTION
REVISIONS:
VERTICAL:
HORIZONTAL:
SCALE
4025 Automation Way
Suite B2
Fort Collins, CO 80525
(970) 698-6046
CivilWorxeng.com
1605 PETERSON PLACE - CARRIAGE HOUSE
C20030
S. CORROUGH 10/14/2020
05
PRELIMINARY
NOT FOR
CONSTRUCTION
PROPOSED UTILITIES
WATER SERVICE
SANITARY SERVICE
LEGEND
EXISTING UTILITIES
WATER LINE
SANITARY LINE
OVERHEAD ELECTRICAL
UNDERGROUND
ELECTRICAL
PREPARED FOR:
JOB NUMBER
SHEET NUMBER
OF SHEETS
DATE SUBMITTED:
The engineer preparing these plans will not be responsible
for, or liable for, unauthorized changes to or uses of these
plans. All changes to the plans must be in writing and
must be approved by the preparer of these plans.
NO. BY DATE
CAUTION
REVISIONS:
VERTICAL:
HORIZONTAL:
SCALE
4025 Automation Way
Suite B2
Fort Collins, CO 80525
(970) 698-6046
CivilWorxeng.com
1605 PETERSON PLACE - CARRIAGE HOUSE
C20030
S. CORROUGH 10/14/2020
05
PRELIMINARY
NOT FOR
CONSTRUCTION
CONSTRUCITON DETAILS
DT01
1" = X'
1" = XX'
XX
WATER SERVICE DETAIL MODIFICATION
SANITARY SERVICE CONNECTION
DETAIL MODIFICATION
TO EXISTING DUPLEX
TO EXISTING SANITARY MAIN CONNECTION
ELECTRICAL BOX/
METER
TELEPHONE BOX
WATER SHUTOFF/
METER
IRRIGATION VALVE
FIBREOPTIC BOX
STREET LIGHT
GAS METER
AC-UNIT
NOTES
1. EXISTING UNDERGROUND AND OVERHEAD
PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE
INDICATED ACCORDING TO THE BEST
INFORMATION AVAILABLE TO THE ENGINEER.
2. THE CONTRACTOR SHALL PROTECT ALL
EXISTING FEATURES THAT ARE NOT TO BE
REMOVED ADJACENT TO THE CONSTRUCTION
AREA INCLUDING, BUT NOT LIMITED TO,
PAVEMENT, PRIVATE FENCES, ABOVE GROUND
OR UNDERGROUND UTILITIES, STRUCTURES,
AND UNDERGROUND FOUNDATIONS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ANY
DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE,
OFF-SITE, PUBLIC OR PRIVATE FACILITY OR
FEATURE AS A RESULT OF THE CONSTRUCTION
PROCESS FOR THIS PROJECT.
3. CONTRACTOR SHALL COORDINATE ALL
CONSTRUCTION ITEMS IMPACTING ADJACENT
PROPERTIES WITH THE PROPERTY OWNERS
PRIOR TO BEGINNING ANY CONSTRUCTION
ACTIVITIES.
MAPPING / SITE
PROPERTY BOUNDARY
PROPOSED EDGE OF
CONCRETE
EXISTING CURB AND
GUTTER
EXISTING FENCE
EXISTING GRAVEL
EXISTING PAVERS
EXISTING CONCRETE
0 10' 20'
SCALE: 1" = 10'
5'
UTILITY PLAN
UT01
N/A
1" = 10'
XX
PREPARED FOR:
JOB NUMBER
SHEET NUMBER
OF SHEETS
DATE SUBMITTED:
The engineer preparing these plans will not be responsible
for, or liable for, unauthorized changes to or uses of these
plans. All changes to the plans must be in writing and
must be approved by the preparer of these plans.
NO. BY DATE
CAUTION
REVISIONS:
VERTICAL:
HORIZONTAL:
SCALE
4025 Automation Way
Suite B2
Fort Collins, CO 80525
(970) 698-6046
CivilWorxeng.com
1605 PETERSON PLACE - CARRIAGE HOUSE
C20030
S. CORROUGH 10/14/2020
05
PRELIMINARY
NOT FOR
CONSTRUCTION
0 10' 20'
SCALE: 1" = 10'
5'
DETAILED GRADING PLAN
GR01
N/A
1" = 10'
XX
NOTES
1. SPOT ELEVATIONS ARE TO FINISHED
SURFACE, CONSULT LANDSCAPER FOR
MINIMUM TOPSOIL DEPTH OR AMENDMENT
PRIOR TO SEEDING.
2. THE CONTRACTOR IS RESPONSIBLE FOR
VERIFYING THE FIELD CONDITIONS ARE AS
SHOWN IN THE DRAWINGS. IF THE
CONTRACTOR FINDS DISCREPANCIES THE
CONTRACTOR SHALL CONTACT THE
ENGINEER.
3. TOP OF FOUNDATION ELEVATIONS SHOWN
ARE RECOMMENDED ELEVATIONS AND ARE
FOR INFORMATION ONLY. THEY ARE NOT
MEANT NOR DO THEY REPLACE BUILDERS
PLOT PLANS.
4. ALL DISTURBED AREAS NOT PAVED SHALL BE
RE-VEGETATED.
5. THE CONTRACTOR IS RESPONSIBLE FOR
VERIFYING THE FIELD CONDITIONS ARE AS
SHOWN IN THE DRAWINGS. IF THE
CONTRACTOR FINDS DISCREPANCIES THE
CONTRACTOR SHALL CONTACT THE
ENGINEER.
6. ALL DISTURBED AREAS SHALL BE
REVEGETATED OR LANDSCAPED PER OWNER
(OR REPRESENTATIVE LANDSCAPER'S)
DIRECTION
7. EROSION CONTROL PRACTICES, SITE
PROTECTION, AND REVEGETATION METHODS
SHALL FOLLOW CITY REGULATIONS.
LEGEND
MAPPING / SITE
PROPERTY BOUNDARY
PROPOSED EDGE OF
CONCRETE
PROPOSED CONTOURS
EXISTING CURB AND
GUTTER
EXISTING CONTOURS
EXISTING FENCE
EXISTING GRAVEL
EXISTING PAVERS
EXISTING CONCRETE
GRADING
EROSION CONTROL
LIMITS OF DISTURBANCE
SILT FENCE
WATTLE DIKE
DP
PR-E
BASIN BOUNDARY
DESIGN POINT
BASIN LABEL
MAJOR COEFFICENT
BASIN AREA
FLOW DIRECTION
PROPOSED GRASSES
DRAINAGE SWALE
PR-E
0.24 32.2%
2.4%
WD
SF
TABULATIONS:
PROPOSED CONDITIONS DRAINAGE
SURFACE TYPE AREA (FT^2)
PERCENT
IMPERVIOUS (%)
COMPOSITE
IMPERVIOUS
PROPOSED DRAINAGE
TOTAL AREA 11,175 31.4% 3509
ASPHALT, CONCRETE 676 100% 676
ROOFTOP 1956 90% 1760
GRAVEL 1977 40% 791
PAVERS 396 40% 159
LAWN, LANDSCAPING 6194 2% 123
VERIFYING THE FIELD CONDITIONS ARE AS
SHOWN IN THE DRAWINGS. IF THE
CONTRACTOR FINDS DISCREPANCIES THE
CONTRACTOR SHALL CONTACT THE
ENGINEER.
D-101
GRADING
BASIN BOUNDARY
DESIGN POINT
BASIN LABEL
MAJOR COEFFICENT
BASIN AREA
FLOW DIRECTION
EX-E
0.25 23.9%
LEGEND
MAPPING / SITE
PROPERTY BOUNDARY
CURB AND GUTTER
EXISTING CONTOURS
FENCE
GRAVEL
PAVERS
CONCRETE
2.4%
EXISTING CONTOURS
FENCE
GRAVEL
PAVERS
CONCRETE
UTILITIES
WATER LINE
SANITARY LINE
OVERHEAD ELECTRICAL
UNDERGROUND
ELECTRICAL
ELECTRICAL BOX/
METER
TELEPHONE BOX
WATER SHUTOFF/
METER
IRRIGATION VALVE
FIBREOPTIC BOX
STREET LIGHT
GAS METER
AC-UNIT
NOTES
1. EXISTING UNDERGROUND AND OVERHEAD
PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE
INDICATED ACCORDING TO THE BEST
INFORMATION AVAILABLE TO THE ENGINEER.
2. THE CONTRACTOR SHALL PROTECT ALL
EXISTING FEATURES THAT ARE NOT TO BE
REMOVED ADJACENT TO THE CONSTRUCTION
AREA INCLUDING, BUT NOT LIMITED TO,
PAVEMENT, PRIVATE FENCES, ABOVE GROUND
OR UNDERGROUND UTILITIES, STRUCTURES,
AND UNDERGROUND FOUNDATIONS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ANY
DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE,
OFF-SITE, PUBLIC OR PRIVATE FACILITY OR
FEATURE AS A RESULT OF THE CONSTRUCTION
PROCESS FOR THIS PROJECT.
3. CONTRACTOR SHALL COORDINATE ALL
CONSTRUCTION ITEMS IMPACTING ADJACENT
PROPERTIES WITH THE PROPERTY OWNERS
PRIOR TO BEGINNING ANY CONSTRUCTION
ACTIVITIES.
DEMOLITION
FENCE REMOVAL
PLANTER BOX REMOVAL
SURFACE TYPE AREA (FT^2)
PERCENT
IMPERVIOUS (%)
COMPOSITE
IMPERVIOUS
EXISTING DRAINAGE
TOTAL AREA 11,175 23.4% 2618
ASPHALT, CONCRETE 676 100% 676
ROOFTOP 1044 90% 939
GRAVEL 1744 40% 698
PAVERS 396 40% 159
LAWN, LANDSCAPING 7315 2% 146
TABULATIONS:
EXISTING CONDITIONS DRAINAGE
4025 AUTOMATION WAY, SUITE B2
FORT COLLINS, CO 80525
PHONE: (970) 698-6046
CONTACT: SCOTT NESBITT
SURVEYOR
MAJESTIC SURVEYING
111 VALLEY DRIVE #104
WINDSOR, CO 80550
PHONE: (970) 443-0882
CONTACT: STEVEN PARKS
PROJECT TEAM
PROJECT COORDINATES
PROJECT VERTICAL DATUM:
CITY OF FORT COLLINS VERTICAL BENCHMARK C-322
ELEVATION = 4990.33 (NAVD88 VERTICAL DATUM)
PROJECT HORIZONTAL DATUM:
MODIFIED NAD83/2011 COLORADO STATE PLANE
COORDINATE SYSTEM, NORTH ZONE
SCALE FACTOR 1.0002644699258 (0.999735650)
Notes:
1. UNDERGROUND UTILITY LOCATES PROVIDED BY PRIMO LOCATING SERVICES, LLC.
2. THIS IS NOT A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLAT.
ALL LOT LINES, RIGHT OF WAY AND EASEMENT LINES ARE TO BE CONSIDERED APPROXIMATE.
3. ALL CONTROL SHOWN SHALL BE VERIFIED BY THE CONTRACTOR
BEFORE ANY CONSTRUCTION OR OTHER IMPROVEMENTS
SITE
PROJECT
COVER SHEET
CV01
N/A
1" = 250'
1
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
Call before you dig.
R
Drawing Index
Sheet Number Sheet Title
GENERAL INFORMATION
CV01 COVER SHEET
CIVIL
EX01 EXISTING CONDITIONS
EXDN01 EXISTING DRAINAGE MAP
GR01 DETAILED GRADING PLAN
UT01 UTILITY PLAN
CIVIL DETAILS
DT01 CONSTRUCITON DETAILS