HomeMy WebLinkAboutCITY UTILITIES SERVICE CENTER PUD FINAL - 16 90A - REPORTS - CITIZEN COMMUNICATIONA. P. SCOTT POST OFFICE BOX 1228 PACIFIC PALISADES. CALIFORNIA 90272 930 N. Shields Fbrt Collins 3- Planning and Zoning Board City of Fort Collins Y June 8, 1990 Thank you for your courtesy in allowing me to speak in regards to the exterior lighting for the addition to the City maintainance yard on Wood Street. Shortly after the Board meeting Mr. Jack Gionolia and Mr. Ken Mannon contacted me. We met and discussed the propossed as well as the existing lighting in both City yards located on Wood Street. The result of this meeting, as well as discussion during previous meetings was that they will try to mitigate the impact of the lighting on my property by several means. These will include possible replacement of fixtures, possibly turning off some of the lights, possibly shrouding some lights as well as constructing a berm and landscaping which will help control low level light as well as noise. I realize that some lighting is thought to be necessary but through the efforts of Messrs. Mannon and Gionolia my property will surely be less impacted. I thank these gentlemen as well as the members of the Board for your continued efforts and concern. Respectfully, t OVS 50-25WATT FLAT GLASS ROADWAY LIGHTING OVS Flat Glass Roadway fixtures feature a heat and impact resistant flat lens that reduces side brightness and glare. It provides cut-off of uplight to minimize "sky -light -pollution:' These units are ideal for lighting roadways, residential neighbor- hoods, and parking areas as well as large site lighting. The OVS Flat Glass units fulfill today's demands for performance and appearance. Design Features • Removable Flat Glass—OVS heat and impact resistant Flat Glass cover can be easily removed for cleaning without tools. • Die -Cast Aluminum Housing —Consists of a top housing and a hinged, one-piece globe ring/ access door. • Die -Cast Two -Position Latch-2-position safety latch is specially designed to be opened with the gloved hand. • Filtered Optical System —A dacron-polyester, non -wicking, filtering gasket is positively held in place on the reflector. • Four-bolt/Two-bracket Slipfitter—An enclosed slipfitterwith 2 non -corrosive brackets and a 4-bolt mounting assembly provides positive attachment and easy leveling on 1'/," or 2" mounting arms. How to Specify: Roadway fixture is to be constructed of a die- cast aluminum upper housing and a one-piece bottom door/ globe ring, hinged at the back and latched on the street side with a die-cast aluminum 2-position latch. The fixture shall attach to either a 1'/," or 2" mast arm with a 4-bolt. 2-bracket mounting arrangement that will provide ease in leveling with positive holding against severe impact or vibration. Afactory-installed birdguard shall fit snugly around either a 1 Y,," or 2" mounting tenon. The optical system shall be sealed with a non -wicking, breathing and filtering gasket of dacron-polyester, die -cut and overlaid A CROUSE-HINDS LIGHTING • Fixed -in -place Birdguard—A factory -installed plastic birdguard fits tightly around the 1 X" or 2" mounting arm. It is designed to keep out wasps as well as birds. • Floating Anodized Aluminum Reflector —The reflector is hydroformed of high quality reflector aluminum and anodized to provide ease of clean- ing and continued performance. The reflector is spring -mounted and''floats" into a sealed position as the door is closed. • Encapsulated Starters —The critical components of the High Pressure Sodium starter are safely encapsulated in an epoxy compound protecting them from mechanical and environmental abuse. • Porcelain Terminal Block —The low resistance "tunnel -type" compression terminals are electro- plated for use with either copper or aluminum supply leads. These "tunnel -type" terminals are mounted on a solid, glazed porcelain terminal block which resists dirt accumulation and "voltage tracking:' • Swing -Down Ballast Assembly —A removable power pack is available as an option. This provides a quick -disconnect and easy removal of the power "bridge" to reduce weight at installation and for quick replacement should maintenance be required. to eliminate voids that occur with butt -joining. Gaskets to be cemented full perimeter to the reflector seat with no metallic clips or fasteners. Lens shall be flat glass heat- and impact -resistant. The unit shall be prewired to a porcelain terminal block with "tunnel -type" compression terminals to accept incoming supply lines. Photocontrol receptacles where required shall be provided with a stop to prevent rotation beyond 3500 and shall be UL approved. Starting aids where required shall be fully encapsulated to protect the components against physical damage and attack by adverse atmospheric conditions. VICKSBURG, MISSISSIPPI 39180 KI Glendale':-:, A" 4r' r T" 4 L l ♦ i Al I ' 9 • V 4�" Poles are made from a single piece of hot -rolled resulting in increased strength and a smooth steel, having only one longitudinal weld. Pales weld. Rate of taper:.10" per foot. Pole shafts are made in the round, and then cold -rolled over have four radiused corners. a mandrel to obtain the square cross-section, STS01 10.0' 48.0 4.75x3.75" 11 go P 13.50" 4.50" 4.25" 75xIW" 11.00" 2.75" STS02 12.5 41.8 5.00x3.75 11 P 13.50 4.50 4.50 .75xl6x2 11.00 2.75 STS03 15.0 32.6 5.50675 11 P 13.50 4.50 4.75 .75x16x2 11.00 2.75 STS24 20.0 30.1 6.250.75 11 P 13.50 4.50 4.75 .75x16x1 10.75 3.50 STS25 25.0 21.5 6.256.75 11 P 13.50 4.50 5.25 1x36x4 12.00 3.75 STS26 30.0 18.5 7.006.75 11 P 13.50 4.50 5.75 436x4 12.50 3.75 STS27 35.0 13.1 7.000.15 11 P 13.50 1 4.50 6.25 106x4 13.00 3.75 STS28 39.0 13.8 7.15z3.75 11 P 13.50 4.50 6.75 10z4 13.50 3.75 Pole Options 0- Single Weatherproof Receptacle T- Duplex Weatherproof Receptacle GFO -Single Ground Fault Receptacle GFT- Duplex Ground Fault Receptacle Poles are made from a single piece of welded tubing of hot -rolled steel. The single [ongitudi- nai weld is of highest quality, and invisible in 4 F � C Qo .2 4o Z 3 c 4o Ma 30,E Oc the finished pole. Pole shafts have four rodi- used comers. C� ti0 CC J C .COS ~ :? SSS01 6.0' 28.9 3.0" 11 go P 9.00" 3.50" 1.50" .62xIW" 7.00" 2.75" SSS02 7.5 22.7 3.0 11 P 9.00 3.50 2.50 .62xI6z2 1 7.00 1.15 SSS05 7.5 37-5 4.0 11 P 9.00 3.50 3.50 .75xI6x2 9.19 3.00 SSS03 10.0 16.2 3.0 11 P 9.00 3.50 2.50 .62xI6x2 7.00 2.75 SSS06 10.0 27.1 4.0 11 P 9.00 3.50 3.50 .75xI6x2 9.19 3.00 SSSO4 12.5 12.2 3.0 11 P 9.00 3.50 2.50 .62xI6x2 7.00 2.75 SSS07 12.5 20.6 4.0 11 P 9.00 3.50 3.50 .75xI6x2 9.19 3,00 SSS08 15.0 12.1 4.0 11 P 9.00 3.50 3.50 .75x16x2 9.19 3.00 SSSII 15.0 35.8 5.0 7 P 10.00 3.50 4.50 .75x16x1 11.00 3.00 SSS09 17.5 9.2 4.0 11 P 9.00 ISO 3.50 .75xl6x2 9.19 3.00 SSS12 17.5 29.3 5.0 7 P 10.00 3.50 4.SO .15xl6x2 11.00 3.00 SSSIO 20.0 6.9 CO 11 P 1 10.00 3.50 3.50 .75x16x2 11.00 3.00 SSSi3 10.0 24.1 5.0 7 P 10.00 3.50 4.50 1 75x16x2 11.00 3.00 SSS15 20.0 32 4 1 6.0 7 P 13.50 4.50 5.50 1 1x36x4 14.50 4.00 SSS14 25.0 16.6 5.0 7 P 10.00 3.50 4.50 .75x32x4 11.00 3.00 SSS16 25.0 22.6 6.0 7 P 13.50 4.50 5.50 1z36x4 14.50 4.00 SSS20 30.0 9.8 5.0 7 P 10.00 3.50 4.50 ISx32z4 11.00 3.00 SSS17 30 113.1 6.0 7 P 13.50 4.50 S.SO 1x36x4 14.50 4.00 Pole Options 0- Single Weatherproof Receptacle T- Duplex Weatherproof Receptacle GFO -Single Ground Fault Receptacle GFT- Duplex Ground Fault Receptacle Addifional Wind toad Rafings on pages 18 & 19. Square Tapered Steel Style STS 13 Square Straight Steel Style SSS 0 1 2 3 4 I5 5 4 3 2 1 0 1 2 3 4 5 A C D E F G H I J K L Lj IL LIR'n ff AFA EN 0 ENNEWMEMENE 400 W Metal Halide Phoometroic t Type VS Vertical Square Data A C D E F G H I J K L Is AikltilLimill ILI M �.ffi =M W-Woom 0 ME EMMUM 'NEON 0 1 2 3 4 5 I5 4 3 2 1 0 1 2 3 4 5 0.5 0 0.4 002 N c nU U 0.1 V 0 1 2 3 4 5 Street Width / Mounting Height STREET SIDE HOUSE SIDE _. _= o= a uo 8;4 Footcandle Values for the Following Curves A B I C I D I E F I G I H I I I I/J J K L I 1 8.5 7.1 4.4 2.8 1.8 1.1 1 .71 .44 .36 .28 .18 .11 24 18 2 17 14 8.9 5.6 3.6 2.2 1.4 .89 .71 .56 .36 .22 4.7 4 1 6.8 5.8 3.6 2.31.4 .90 .58 36 .29 .23 .14 .09 1.9 20 2 14 12 7.2 4.5 2.9 1.8 12 1 .7 .59 .45 .29 .18 3.8 4 1 4.4 3.7 2.3 1.4 .92 .58 .37 .23 .18 .14 .09, .06 1.2 5 2 8.8 7.4 4.6 2.911.8 1.2 .74 .46 .37 .29 .18 .12 2.5 4 1 3.0 2.6 1.6 1.0 .64 .40 .26 .16 .13 .10 .061 04 .85 0 2 6.1 5.1 3.2 2.0 1.3 .80 .51 .32 .26 .20 .13 .08 1.7 4 12 10 6.4 4.0 2.6 1.6 1.0 .64 .51 .40 .261 .16 3.4 1 5 2 4A 3.8 2.4 1.5 .94 .58 .38 .24 .18 .15 .091i .06 1.2 4 8.9 7.5 4.7 2.9 1.9 1.2 .75 67 .38 .29 .19i .12 2.5 1 40 2 4 6.8 5.7 3.6 2.2 1.4 .90 .17 .36 .28 .22 .14 .09 1.9 1 45 2 4 5.4 4.5 2.8 1.8 1.1 .70 .45 .28 .22 .18 11i .07 1.5 1 I 50 2 J443.7 4 2.3 1.4 .92 .58 .37 .23 .18 .14 .09 .06 1.2 Footcandles Per 1000 Lamp Lumens 0 1 076 .061 .040 025 .016 . .0064 OOaO 0002 .0025 001 001 1k APPROXIMATE AVERAGE INITIAL FOOTCANOLES Single Units-6 MH x 6 MH Spacing Multiple Units-6 MH x 6 MH Spacing