Loading...
HomeMy WebLinkAboutFCLWD GOLDEN CURRANT WATER LINE - SPA200002 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANS1" = N/A 1" = N/A D:\CIVILWORX DROPBOX\CIVILWORX\PROJECTS\C18015 - FCLWD GOLDEN CURRANT\C18015 - FCLWD GOLDEN CURRANT - CADD\CP\CX.XX_COVER SHEET.DWG CX.XX_COVER SHEET ## ## CS01 GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 VICINITY MAP PROJECT TEAM 1" = 500' PROJECT SITE GOLDEN CURRANT WATER LINE FORT COLLINS LOVELAND WATER DISTRICT, LARIMER COUNTY, COLORADO. PUBLIC IMPROVEMENT CONSTRUCTION PLANS CIVIL ENGINEER CIVILWORX, LLC 4025 AUTOMATION WAY, SUITE B2 FORT COLLINS, CO 80525 OFFICE PHONE: 970-698-6046 CONTACT: AUSTIN SNOW, PE CELL PHONE: 970-825-9740 OWNER FORT COLLINS LOVELAND WATER DISTRICT 5150 SNEAD DRIVE FORT COLLINS, CO 80525 OFFICE PHONE 970-226-3104 CONTACT: CHRIS PLETCHER, PE CELL PHONE: 970-218-5546 SURVEYOR WASHBURN LAND SURVEYING, LLC 4025 AUTOMATION WAY SUITE C4 SOUTH FORT COLLINS, CO 80526 1" = N/A 1" = N/A D:\CIVILWORX DROPBOX\CIVILWORX\PROJECTS\C18015 - FCLWD GOLDEN CURRANT\C18015 - FCLWD GOLDEN CURRANT - CADD\CP\GN.XX_GENERAL NOTES.DWG GN.XX_GENERAL NOTES ## ## GN01 GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1" = N/A 9/11/2020 8:37:37 AM D:\CIVILWORX DROPBOX\CIVILWORX\PROJECTS\C18015 - FCLWD GOLDEN CURRANT\C18015 - FCLWD GOLDEN CURRANT - CADD\CP\GN.XX_GENERAL NOTES.DWG GN.XX_GENERAL NOTES ## ## GN01 GENERAL NOTES LARIMER COUNTY URBAN AREA ROAD STANDARDS - GENERAL NOTES (4/1/2017) ("DEVELOPER" SHALL REFER TO THE GENERAL CONTRACTOR FOR FORT COLLINS LOVELAND WATER DISTRICT) GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the Local Entity. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the Local Entity Engineer. Use of these plans after the expiration date will require a new review and approval process by the Local Entity prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the Local Entity, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the Local Entity Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted GOLDEN CURRANT BLVD S OVERLAND TRAIL REMOVE AND REPLACE EXISTING ASPHALT FOR ABANDONMENT OF EXISTING 16" WL SEE SHEET AB01 WOODROSE CT WHEATGRASS CT W PROSPECT RD BANYAN DR S OVERLAND TRAIL REMOVE AND REPLACE EXISTING CONCRETE PAN REMOVE AND REPLACE EXISTING CONCRETE TRAIL REMOVE AND REPLACE EXISTING GRASS / SOD REMOVE AND REPLACE EXISTING CONCRETE SIDEWALK REMOVE AND REPLACE EXISTING CONCRETE SIDEWALK REMOVE AND REPLACE EXISTING CONCRETE CURB AND GUTTER REMOVE AND REPLACE EXISTING CONCRETE CURB AND GUTTER REMOVE AND REPLACE CONCRETE CROSSPAN REMOVE AND REPLACE EXISTING ASPHALT REMOVE AND REPLACE EXISTING ASPHALT REMOVE AND REPLACE EXISTING FENCE REMOVE AND REPLACE EXISTING STORM PIPE REMOVE AND REPLACE EXISTING TREE REMOVE AND REPLACE EXISTING TREES REMOVE AND REPLACE EXISTING ASPHALT FOR ABANDONMENT OF EXISTING 16" WL SEE SHEET AB01 PROPOSED 20" FCLWD WATER LINE 1" = 30' N/A RM01 0 30' 60' SCALE: 1" = 30' 15' DEMOLITION AND REMOVALS PLAN N GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible PROPOSED PIPE ALIGNMENT LIES WITHIN EXTENTS OF ACCESS ROAD IN THIS AREA ACCESS ROAD TO BE EXCAVATED AND REPAIRED FOR PIPE INSTALLATION AS NECESSARY SPRUCE DR SPRUCE DR REMOVE AND REPLACE EXISTING TREE 1" = 30' N/A RM02 DEMOLITION AND REMOVALS PLAN GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, PAVEMENT, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. CURB, GUTTER, SIDEWALK, AND CONCRETE PANS SHALL BE REMOVED TO THE NEAREST JOINT. 4. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING 0 100' 200' SCALE: 1" = 100' 50' N CITY OF FORT COLLINS MAXWELL NATURAL AREA PONDS AT OVERLAND TRAIL HOA OPEN SPACE CITY OF FORT COLLINS WATER TANK FCLWD WATER TANKS TREES TO BE PROTECTED PROPOSED FCLWD 20" WATERLINE PROPOSED FCLWD 20" WATERLINE FCLWD TANK ACCESS ROAD DIXON CANAL AND ACCESS ROAD CROSSING GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 EROSION CONTROL PLAN EC01 N/A 1" = 100' 5 GOLDEN CURRANT BLVD CATALPA CT CITY OF FORT COLLINS TANK ACCESS ROAD CONSTRUCTION DISTURBANCE MUST BE CONTAINED WITHIN THE 50' CONSTRUCTION EASEMENT. ACCESS TO THE TANK TO BE MAINTAINED AT ALL TIMES. 0 100' 200' SCALE: 1" = 100' 50' N PONDS AT OVERLAND TRAIL HOA OPEN SPACE PROPOSED FCLWD 20" WATERLINE PONDS AT OVERLAND TRAIL DETENTION POND BANYAN DRIVE WEST PROSPECT ROAD OVERLAND TRAIL GOLDEN CURRANT BLVD. GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 EROSION CONTROL PLAN EC02 N/A 1" = 100' 6 BANYAN DRIVE REEDGRASS CT. HONEYSUCKLE CT. GOLDEN CURRANT CT. 1. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE FIELD CONDITIONS ARE AS SHOWN IN THE DRAWINGS. IF THE CONTRACTOR FINDS DISCREPANCIES THE CONTRACTOR SHALL CONTACT THE ENGINEER. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR NECESSARY TEMPORARY RE-VEGETATION DURING CONSTRUCTION AND THROUGH SUBSTANTIAL COMPLETION. 0 180' 360' SCALE: 1" = 180' 90' N GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 OVERALL UTILITY PLAN UT01 N/A 1" = 180' 7 LEGEND MAPPING / SITE PROPERTY BOUNDARY RIGHT-OF-WAY LOT LINES EASEMENTS CENTER LINE CURB AND GUTTER EXISTING CONTOURS PROPOSED CONTOURS EXISTING UTILITIES WATER LINE MAIN SANITARY SEWER MAIN STORM DRAIN PIPE SANITARY SEWER MANHOLE STORM DRAIN MANHOLE OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE PROPOSED UTILITIES SANITARY SEWER MAIN SANITARY SERVICE 0 100' 200' SCALE: 1" = 100' 50' N CITY OF FORT COLLINS MAXWELL NATURAL AREA PONDS AT OVERLAND TRAIL HOA OPEN SPACE CITY OF FORT COLLINS WATER TANK FCLWD WATER TANKS TREES TO BE PROTECTED EXISTING COFC 24" WATERLINE PROPOSED FCLWD 20" WATERLINE EXISTING FCLWD 16" WATERLINE (TO BE ABANDONED, SEE SHEET AB01) PROPOSED FCLWD 20" WATERLINE EXISTING COFC 24" WATERLINE OVERHEAD ELECTRIC LINES FCLWD TANK ACCESS ROAD DIXON CANAL AND ACCESS ROAD CROSSING EXISTING FCLWD 8" WATERLINE (TO BE ABANDONED, SEE SHEET AB01) GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 UTILITY PLAN UT02 N/A 1" = 100' 8 GOLDEN CURRANT BLVD 20"X8" TEE 0 100' 200' SCALE: 1" = 100' 50' N PONDS AT OVERLAND TRAIL HOA OPEN SPACE PROPOSED FCLWD 20" WATERLINE EXISTING COFC 24" WATERLINE 20' EASEMENT PONDS AT OVERLAND TRAIL DETENTION POND PROPOSED FCLWD 20" WATERLINE BANYAN DRIVE WEST PROSPECT ROAD OVERLAND TRAIL GOLDEN CURRANT BLVD. EXISTING FCLWD 36" TRANSMISSION MAIN EXISTING FCLWD 20" TRANSMISSION MAIN EXISTING FCLWD 16" WATERLINE (TO BE ABANDONED SEE SHEET AB01) GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 UTILITY PLAN UT03 N/A 1" = 100' 9 20" x 0.75" CC SADDLE FOR 0.75" PEX-A SERVICE LINE REPLACE METER PIT BANYAN DRIVE REEDGRASS CT. 0 150' 300' SCALE: 1" = 150' 75' N BANYAN DRIVE OVERLAND TRAIL GOLDEN CURRANT BLVD. GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 OVERALL SHEET INDEX OA01 N/A 1" = 100' 10 SEE SHEET WT01 SEE SHEET WT02 SEE SHEET WT03 SEE SHEET WT04 SEE SHEET WT05 SEE SHEET WT06 SEE SHEET WT07 WOODROSE W PROSPECT RD BANYAN DR S OVERLAND TRAIL BANYAN DR 8" FCLWD WATER LINE TO BE ABANDONED EXISTING COFC STORM SEWER EXISTING COFC STORM SEWER EXISTING COFC STORM SEWER EXISTING COFC 24" WATER LINE STA: 18+19.52 11.25° BEND N. 1450297.56 E. 3101785.05 STA: 17+85.90 11.25° BEND N. 1450291.42 E. 3101818.11 STA: 17+05.51 22.5° AND 45° BENDS N. 1450293.72 E. 3101898.46 STA: 16+69.31 11.25° BEND N. 1450328.86 E. 3101907.12 STA: 15+34.91 90° BEND N. 1450452.15 E. 3101960.65 STA: 13+28.69 11.25° AND 22.5° BENDS N. 1450375.25 E. 3102151.99 STA: 12+25.45 22.5° BEND N. 1450393.61 E. 3102253.58 STA: 11+59.44 11.25° AND 22.5° BENDS N. 1450432.05 E. 3102307.25 STA: 11+55.15 AIR/VACUUM VALVE N. 1450432.00 E. 3102311.54 STA: 15+16.91 BLOWOFF N. 1450445.44 E. 3101977.35 STA 10+00.00 BEGIN CONSTRUCTION CUT IN 36"x20" TEE 18+00 19+00 22+00 21+00 20+00 25+00 24+00 23+00 BANYAN DR PROPOSED 3/4" - PEX-A WATER SERVICE 111 FT 8" FCLWD WATER LINE TO BE ABANDONED REPLACE METER PIT CUT AND REPAIR GRAVEL ROAD OHE CROSSING EXISTING 24" COFC WATERLINE STA: 18+19.52 11.25° BEND N. 1450297.56 E. 3101785.05 STA: 17+85.90 11.25° BEND N. 1450291.42 E. 3101818.11 STA: 24+03.94 3 4" PEX-A SERVICE CONNECTION VIA 20" x 3 4" SADDLE N. 1450252.00 E. 3101202.41 S79°28'35"E 33.62' N88°21'51"E 80.39' 18+00 19+00 22+00 21+00 20+00 25+00 24+00 23+00 20" WATERLINE PROFILE 5115 5120 5125 5130 5135 5140 5145 5150 5155 5160 5165 5115 5120 5125 5130 5135 5140 5145 5150 5155 27+00 26+00 29+00 28+00 31+00 30+00 33+00 32+00 SPRUCE DR 8" WATER LINE TO BE ABANDONED IN PLACE SEE SHEET AB-01 8" WATER LINE TO BE ABANDONED IN PLACE SEE SHEET AB-01 EXISTING 24" COFC WATERLINE EXISTING 24" COFC WATERLINE N85°31'42"E 2152.29' 27+00 26+00 29+00 28+00 31+00 30+00 33+00 32+00 20'' WATERLINE PROFILE 5150 5155 5160 5165 5170 5175 5180 5185 5190 5195 5200 5150 5155 5160 5165 5170 5175 5180 5185 5190 5195 5200 33+50 33+00 32+50 32+00 31+50 31+00 30+50 30+00 29+50 29+00 28+50 28+00 27+50 27+00 26+50 26+00 25+50 20" PVC WATERLINE 5' MIN BURY DEPTH EXISTING GROUND AT PIPE CENTERLINE STA = 25+97.34 TOP = 5155.91' VERTICALLY DEFLECT PIPE 1.2° TOTAL ACROSS NEAREST (2) JOINTS STA = 29+18.86 TOP = 5171.21' VERTICALLY DEFLECT PIPE 1.2° TOTAL ACROSS NEAREST (2) JOINTS STA = 31+61.01 TOP = 5178.59' VERTICALLY DEFLECT PIPE 3° TOTAL ACROSS NEAREST (3) JOINTS 35+00 34+00 33+00 39+00 38+00 37+00 36+00 40+00 41+00 42+00 SPRUCE DR CONNECT REDUCER TO 100 LF OF 6" PVC 8" WATER LINE TO BE ABANDONED IN PLACE SEE SHEET AB-01 CONNECT TO EXISTING 6" PIPE WITH 6" SLEEVE CUT AND CAP EXISTING 8" WL ABANDON IN PLACE EXISTING 24" COFC WATERLINE FIELD VERIFY DEPTH OF EXISTING 24" COFC WATERLINE DEFLECT OR LOWER 6" PVC WATERLINE IF NECESSARY STA: 39+71.70 45° BEND N. 1450129.94 E. 3099639.40 STA: 35+05.55 20"x8" TEE WITH 8" GATE VALVE (S) FOLLOWED BY 8" TO 6" REDUCER 20" BFV (E & W) N. 1450166.11 E. 3100104.15 STA: 34+16.31 AIR/VACCUM VALVE N. 1450173.41 E. 3100193.09 STA: 40+19.47 22.5° BEND N. 1450160.74 E. 3099603.11 STA: 40+32.18 AIR/VACCUM VALVE N. 1450172.01 E. 3099597.23 STA: 42+30.07 11.25° BEND N. 1450367.67 E. 3099573.87 STA: 40+44.47 22.5° BEND N. 1450182.92 E. 3099591.57 S5°28'21"E 185.63' S27°28'26"E 25.00' S49°28'27"E 47.63' STA: 35+80.91 BLOWOFF N. 1450160.22 E. 3100029.03 5200 5205 5210 5215 5220 5225 5230 5235 5240 5245 5250 5200 5205 5210 5215 5220 5225 5230 5235 5240 5245 5250 49+50 49+00 48+50 48+00 47+50 47+00 46+50 46+00 45+50 45+00 44+50 44+00 43+50 43+00 42+50 42+00 41+50 20" PVC WATERLINE 5' MIN BURY DEPTH EXISTING GROUND AT PIPE CENTERLINE JOINT RESTRAINT STA 42+25 TO STA 45+07 JOINT RESTRAINT STA 47+44 TO STA 48+94 24" CITY WATERLINE APPROX 4' BELOW GRADE (FIELD VERIFY) MAINTAIN 12" SEPARATION FROM B.O.P. STA = 47+63.24 TOP = 5232.33' VERTICALLY DEFLECT PIPE 2° TOTAL ACROSS NEAREST (2) JOINTS STA = 43+65.92 TOP = 5207.95' VERTICALLY DEFLECT PIPE 3.4° TOTAL ACROSS NEAREST (4) JOINTS STA = 46+09.69 TOP = 5220.45' VERTICALLY DEFLECT PIPE UNDER EXISTING CITY OF FORT COLLINS PIPE APPROX 1.5° TOTAL ACROSS NEAREST (2) JOINTS BEGIN 2° TOTAL DEFLECTION ACROSS NEXT (2) JOINTS AFTER STA 47+25 BEGIN 1.5° TOTAL DEFLECTION ACROSS NEXT (2) JOINTS AFTER STA 45+75 BEGIN 3.4° TOTAL DEFLECTION ACROSS NEXT (4) JOINTS AFTER STA 43+25 20'' WATERLINE PROFILE 5250 5255 5260 5265 5270 5275 5280 5285 5290 5295 5300 5250 5255 5260 5265 5270 5275 5280 5285 5290 5295 5300 57+00 56+50 56+00 55+50 55+00 54+50 54+00 53+50 53+00 52+50 52+00 51+50 51+00 50+50 50+00 49+50 20" PVC WATERLINE EXISTING GROUND AT PIPE CENTERLINE 5' MIN BURY DEPTH JOINT RESTRAINT STA 50+33 TO STA 50+54 JOINT RESTRAINT STA 51+37 TO STA 51+58 JOINT RESTRAINT STA 52+54 TO STA 53+42 JOINT RESTRAINT STA 55+41 TO STA 55+74 STA = 51+17.45 TOP = 5271.69' VERTICALLY DEFLECT PIPE 6.3° TOTAL ACROSS NEAREST (7) JOINTS STA = 53+10.12 TOP = 5272.12' VERTICALLY DEFLECT PIPE 5° TOTAL ACROSS NEAREST (5) JOINTS STA = 54+08.53 TOP = 5280.95' VERTICALLY DEFLECT PIPE 3.7° TOTAL ACROSS NEAREST (4) JOINTS STA = 54+99.42 TOP = 5283.23' VERTICALLY DEFLECT PIPE 1.3° TOTAL ACROSS NEAREST (2) JOINTS STA = 55+55.43 TOP = 5285.86' VERTICALLY DEFLECT PIPE 5.9° TOTAL ACROSS NEAREST (6) JOINTS 3" COMBINATION AIR/VACUUM VALVE @ STA 55+55.25 STA = 56+82.11 TOP = 5278.77' 55+00 56+00 57+00 58+00 59+00 60+00 61+00 62+00 62+62 N23°19'20.13"W 35.26' STA: 55+55.25 AIR/VACCUM VALVE N. 1451135.69 E. 3098774.38 STA: 61+89.05 AIR/VACCUM VALVE N. 1451418.41 E. 3098305.69 STA: 56+82.92 BLOWOFF N. 1451242.37 E. 3098705.24 STA: 55+69.18 11.25° BEND N. 1451146.36 E. 3098765.43 STA: 56+49.58 11.25° BEND N. 1451216.76 E. 3098726.59 STA: 57+52.09 22.5° BEND N. 1451295.54 E. 3098661.02 STA: 59+10.50 45° BEND N. 1451430.72 E. 3098583.97 STA: 62+08.59 22.5° BEND N. 1451417.49 E. 3098286.17 STA: 62+27.02 45° BEND N. 1451422.44 E. 3098268.41 STA: 62+62.28 CONNECT TO EXISTING 16" WATER LINE VIA 20"x16" REDUCER AFTER NEW LINE HAS BEEN TESTED AND ACCEPTED N. 1451454.82 E. 3098254.45 STA: 62+60.41 20"x16" REDUCER N. 1451453.10 E. 3098255.19 STA: 62+01.05 20" BFV CUT AND CAP EXISTING 16" WL AFTER TIE IN OF NEW 20" WL EXISTING 16" WL TO BE FLASH-FILLED PRIOR TO BEING CAPPED FOR ABANDONMENT GOLDEN CURRANT BLVD S OVERLAND TRAIL CUT 36" MIN. OF EXISTING 16" WL AT CROSS CONNECTION IN OVERLAND TRAIL AND PLUG (CONCRETE) EXISTING 16" WL TO BE FLASH-FILLED PRIOR TO PLUG REMOVE 16" VALVE RESTRAINED PLUG ON TEE/CROSS AT CONNECTION SPRUCE DR REMOVE TEE 24" MIN. OF EXISTING 8" WL AT CONNECTION AND PLUG RE-CONNECT 6" SERVICE LINE WITH 6" SLEEVE W PROSPECT RD S OVERLAND TRAIL CUT 24" MIN. OF EXISTING 8" WL AT CROSS CONNECTION IN OVERLAND TRAIL AND CAP. REMOVE 8" VALVE RESTRAINED PLUG ON TEE/CROSS AT CONNECTION 1" = 30'' AB01 ABANDONMENT PLAN GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, PAVEMENT, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, 1" = N/A 1" = N/A CD_CONSTRUCTION DETAILS ## ## DT01 GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1" = N/A 9/11/2020 9:42:50 AM D:\CIVILWORX DROPBOX\CIVILWORX\PROJECTS\C18015 - FCLWD GOLDEN CURRANT\C18015 - FCLWD GOLDEN CURRANT - CADD\CP\CD_CONSTRUCTION DETAILS.DWG CD_CONSTRUCTION DETAILS ## ## DT01 CONSTRUCTION DETAILS 2" VENT PIPE 4' MIN. 2" PIPE SCREEN 19 1" = N/A 9/11/2020 9:43:08 AM D:\CIVILWORX DROPBOX\CIVILWORX\PROJECTS\C18015 - FCLWD GOLDEN CURRANT\C18015 - FCLWD GOLDEN CURRANT - CADD\CP\CD_CONSTRUCTION DETAILS.DWG CD_CONSTRUCTION DETAILS ## ## DT02 CONSTRUCTION DETAILS 1" = N/A 1" = N/A CD_CONSTRUCTION DETAILS ## ## DT02 GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 20 AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 4. CONTRACTOR SHALL COORDINATE ALL NECESSARY APPROVALS, PERMISSIONS, AND PERMITTING FOR WORK WITHIN ROADWAYS (E.G. TRAFFIC CONTROL, ROAD CLOSURES, ETC.) LEGEND NOTES LOT LINES EASEMENT LINES CENTERLINE EXISTING MAPPING AND SITE CURB AND GUTTER INTERMEDIATE CONTOUR INDEX CONTOUR EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. WATER VALVE FIRE HYDRANT ELECTRIC POLE WATER / SANITARY PLUG WATER METER WATER VAULT FENCE PROPERTY BOUNDARY RIGHT-OF-WAY 5078 5080 EXISTING WATER LINES TO BE ABANDONED ABANDONMENTS ELECTRIC LINE OVERHEAD ELECTRIC LINE FIBER, GAS, ELECTRIC, OR TELEPHONE PEDESTALS 0' U.S. SURVEY FEET SCALE: 1" = 30' 15' 30' 60' EXISTING 8' FCLWD WATER LINE OFF SPRUCE DRIVE - WEST SIDE EXISTING 16' FCLWD GOLDEN CURRANT WATER LINE - EAST SIDE EXISTING 8' FCLWD WATER LINE OFF SPRUCE DRIVE - EAST SIDE EXISTING 16' FCLWD GOLDEN CURRANT WATER LINE - WEST SIDE N/A 18 N. 1451418.26 E. 3098293.69 STA: 58+25.64 22.5° BEND N. 1451365.55 E. 3098638.43 STA: 62+35.49 SAMPLE STATION N. 1451430.23 E. 3098265.06 S74°17'40"E 18.47' N87°28'28"E 298.09' S39°53'13"E 84.93' S17°53'13"E 73.61' S39°46'29"E 102.46' S28°53'08"E 80.41' 55+00 56+00 57+00 58+00 59+00 60+00 61+00 62+00 62+62 20'' WATERLINE PROFILE 5275 5280 5285 5290 5295 5300 5305 5310 5315 5320 5325 5330 5335 5275 5280 5285 5290 5295 5300 5305 5310 5315 5320 5325 5330 5335 62+75 62+50 62+00 61+50 61+00 60+50 60+00 59+50 59+00 58+50 58+00 57+50 57+00 20" PVC WATERLINE 5' MIN BURY DEPTH EXISTING GROUND AT PIPE CENTERLINE JOINT RESTRAINT STA 60+65 TO STA 62+62.28 JOINT RESTRAINT STA 57+42 TO STA 57+63 STA = 58+00.88 TOP = 5278.88' VERTICALLY DEFLECT PIPE 2.9° TOTAL ACROSS NEAREST (3) JOINTS STA = 59+03.31 TOP = 5284.02' VERTICALLY DEFLECT PIPE 4° TOTAL ACROSS NEAREST (4) JOINTS STA = 60+20.01 TOP = 5297.85' VERTICALLY DEFLECT PIPE 2.70° TOTAL ACROSS NEAREST (4) JOINTS STA = 62+08.96 TOP = 5329.08' 11.25° VERTICAL BEND FITTING STA = 61+89.05 TOP = 5325.79' 3" COMBINATION AIR/VACUUM VALVE STA = 62+62.28 TOP = 5329.44' MAKE CONNECTION AT EXISTING PIPING BEGIN 2.9° TOTAL DEFLECTION ACROSS NEXT (3) JOINTS AFTER STA 57+50 BEGIN 4° TOTAL DEFLECTION ACROSS NEXT (4) JOINTS AFTER STA 58+50 BEGIN 2.9° TOTAL DEFLECTION ACROSS NEXT (3) JOINTS AFTER STA 59+75 STA = 62+60.41 TOP = 5329.42' 20"X16" REDUCER STA = 57+52.09 TOP = 5278.84' 22.5° HORIZONTAL BEND STA = 58+25.64 TOP = 5280.13' 22.5° HORIZONTAL BEND STA = 59+10.50 TOP = 5284.87' 45° HORIZONTAL BEND STA = 62+08.59 TOP = 5329.02' 11.25° HORIZONTAL BEND VERTICALLY DEFLECT 1° IN EACH FITTING (2°) STA = 62+27.02 TOP = 5329.20' 45° HORIZONTAL BEND STA = 62+01.05 TOP = 5327.78' 20" BFV STA = 62+35.49 TOP = 5329.26' SAMPLE STATION JOINT RESTRAINT JOINT RESTRAINT STA 58+15 TO STA 58+36 STA 58+90 TO STA 59+31 1" = 5' WT07 0 30' 60' SCALE: 1" = 30' 15' WATERLINE PLAN & PROFILE N GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. BURY DEPTH ON WATERLINE SHALL BE 5' TO FINISHED GRADE UNLESS OTHERWISE DEPICTED IN THESE DRAWINGS. 2. PRESSURE TEST AND DISINFECT NEW WATERLINE BEFORE CONNECTING TO EXISTING PIPING. 3. FITTINGS ADJACENT TO ONE ANOTHER SHALL BE CONNECTED VIA FOSTER ADAPTER. LEGEND NOTES FIRE HYDRANT WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER MH SANITARY SEWER MH OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE MATCHLINE STA: 57+00 SEE SHEET WT06 20" WATERLINE PROFILE 1" = 30' 17 VERTICALLY DEFLECT PIPE 3.3° TOTAL ACROSS NEAREST (4) JOINTS BLOWOFF VALVE AT LOW POINT BEGIN 3.3° TOTAL DEFLECTION ACROSS NEXT (4) JOINTS AFTER STA 56+50 BEGIN 1.3° TOTAL DEFLECTION ACROSS NEXT (2) JOINTS AFTER STA 54+75 BEGIN 5° TOTAL DEFLECTION ACROSS NEXT (5) JOINTS AFTER STA 52+50 BEGIN 3.7° TOTAL DEFLECTION ACROSS NEXT (4) JOINTS AFTER STA 53+50 BEGIN 6.3° TOTAL DEFLECTION ACROSS NEXT (7) JOINTS AFTER STA 50+25 STA = 50+43.67 TOP = 5263.50' 22.5° HORIZONTAL BEND STA = 51+47.69 TOP = 5271.76' 22.5° HORIZONTAL BEND STA = 52+59.78 TOP = 5272.01' 11.25° HORIZONTAL BEND STA = 52+82.76 TOP = 5272.06' 11.25° HORIZONTAL BEND STA = 53+36.34 TOP = 5274.47' 11.25° HORIZONTAL BEND STA = 56+49.58 TOP = 5280.59' 11.25° HORIZONTAL BEND STA = 55+69.18 TOP = 5285.09' 11.25° HORIZONTAL BEND JOINT RESTRAINT STA 56+45 TO STA 56+55 BEGIN 5.9° TOTAL DEFLECTION ACROSS NEXT (6) JOINTS AFTER STA 55+00 50+00 49+00 51+00 52+00 53+00 55+00 54+00 56+00 57+00 STA: 55+55.25 AIR/VACCUM VALVE N. 1451135.69 E. 3098774.38 STA: 56+82.92 BLOWOFF N. 1451242.37 E. 3098705.24 STA: 48+88.92 11.25° BEND N. 1450549.94 E. 3099060.53 STA: 50+43.67 22.5° BEND N. 1450696.88 E. 3099011.95 STA: 51+47.69 22.5° BEND N. 1450787.58 E. 3098961.06 STA: 52+59.78 11.25° BEND N. 1450898.87 E. 3098947.64 STA: 52+82.76 11.25° BEND N. 1450920.75 E. 3098940.59 STA: 55+69.18 11.25° BEND N. 1451146.36 E. 3098765.43 STA: 56+49.58 11.25° BEND N. 1451216.76 E. 3098726.59 STA: 53+36.34 11.25° BEND N. 1450967.68 E. 3098914.71 S39°46'29"E 102.46' S28°53'08"E 80.41' S39°52'34"E 232.83' S28°52'34"E 53.59' S17°52'34"E 22.99' S6°52'34"E 112.09' S29°17'39"E 104.01' S18°17'39"E 154.76' S29°17'39"E 51.80' 50+00 49+00 51+00 52+00 53+00 55+00 54+00 56+00 57+00 1" = 5' WT06 0 ##' ##' SCALE: 1" = ##' ##' WATERLINE PLAN & PROFILE N GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. BURY DEPTH ON WATERLINE SHALL BE 5' TO FINISHED GRADE UNLESS OTHERWISE DEPICTED IN THESE DRAWINGS. 2. PRESSURE TEST AND DISINFECT NEW WATERLINE BEFORE CONNECTING TO EXISTING PIPING. 3. FITTINGS ADJACENT TO ONE ANOTHER SHALL BE CONNECTED VIA FOSTER ADAPTER. LEGEND NOTES FIRE HYDRANT WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER MH SANITARY SEWER MH OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE 20" WATERLINE PROFILE SEE SHEET WT05 MATCHLINE 57+00 MATCHLINE STA: 49+50 SEE SHEET WT07 1" = 30' 16 STA = 43+72.83 TOP = 5208.30' APPROXIMATE PHASE 1 / PHASE 2 BOUNDARY STA = 42+30.07 TOP = 5209.01' 11.25° HORIZONTAL BEND STA = 43+60.04 TOP = 5207.99' 90° HORIZONTAL BEND STA = 47+54.12 TOP = 5231.63' 22.5° HORIZONTAL BEND STA = 47+84.43 TOP = 5234.69' 22.5° HORIZONTAL BEND STA = 48+37.11 TOP = 5240.54' 22.5° HORIZONTAL BEND STA = 48+88.92 TOP = 5246.30' 11.25° HORIZONTAL BEND STA = 43+62.57 TOP = 5207.97' BLOWOFF STA = 43+70.39 TOP = 5208.18' 20" BFV STA = 44+25.62 TOP = 5211.01' DIXON CANAL CROSSING STA = 43+10.09 TOP = 5208.38' 45° HORIZONTAL BEND 42+00 43+00 45+00 44+00 47+00 46+00 48+00 49+00 STA: 43+60.06 90° BEND N. 1450494.49 E. 3099548.07 STA: 47+54.12 22.5° BEND N. 1450462.15 E. 3099155.38 STA: 47+84.43 22.5° BEND N. 1450471.27 E. 3099126.52 STA: 48+37.11 22.5° BEND N. 1450504.76 E. 3099085.88 STA: 48+88.92 11.25° BEND N. 1450549.94 E. 3099060.53 STA: 42+30.07 11.25° BEND N. 1450367.67 E. 3099573.87 STA: 43+10.09 45° BEND N. 1450444.70 E. 3099552.19 S29°17'39"E 51.80' S50°30'20"E 52.71' S72°28'15"E 30.28' N85°16'22"E 393.98' S4°43'38"E 50.00' S15°43'38"E 79.99' S5°28'21"E 185.63' 42+00 43+00 45+00 44+00 47+00 46+00 48+00 49+00 STA: 43+62.55 BLOWOFF N. 1450494.29 E. 3099545.58 STA: 43+70.40 20" BFV N. 1450493.63 E. 3099537.76 STA: 44+28.74 APPROXIMATE CROSSING DIXON CANAL N. 1450488.83 E. 3099479.62 1" = 5' WT05 WATERLINE PLAN & PROFILE N GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. BURY DEPTH ON WATERLINE SHALL BE 5' TO FINISHED GRADE UNLESS OTHERWISE DEPICTED IN THESE DRAWINGS. 2. PRESSURE TEST AND DISINFECT NEW WATERLINE BEFORE CONNECTING TO EXISTING PIPING. 3. FITTINGS ADJACENT TO ONE ANOTHER SHALL BE CONNECTED VIA FOSTER ADAPTER. LEGEND NOTES FIRE HYDRANT WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER MH SANITARY SEWER MH OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE 20" WATERLINE PROFILE SEE SHEET WT06 MATCHLINE 49+50 MATCHLINE STA: 41+50 SEE SHEET WT04 0' U.S. SURVEY FEET SCALE: 1" = 30' 15' 30' 60' 1" = 30' 15 35+00 34+00 33+00 39+00 38+00 37+00 36+00 40+00 41+00 42+00 5185 5190 5195 5200 5205 5210 5215 5220 5185 5190 5195 5200 5205 5210 5215 5220 41+50 41+00 40+50 40+00 39+50 39+00 38+50 38+00 37+50 37+00 36+50 36+00 35+50 35+00 34+50 34+00 33+50 20" PVC WATERLINE 5' MIN BURY DEPTH EXISTING GROUND AT PIPE CENTERLINE JOINT RESTRAINT STA 39+51 TO STA 40+65 STA = 37+52.20 TOP. = 5200.68' VERTICALLY DEFLECT PIPE 1.6° TOTAL ACROSS NEAREST (3) JOINTS STA = 40+32.87 TOP = 5210.55' VERTICALLY DEFLECT PIPE 2.5° TOTAL ACROSS NEAREST (3) JOINTS STA = 34+16.31 TOP = 5202.50' VERTICALLY DEFLECT PIPE 7° TOTAL ACROSS NEAREST (7) JOINTS 3" COMBINATION AIR/VACUUM VALVE @ HIGH POINT STA = 35+80.68 TOP = 5199.25' VERTICALLY DEFLECT PIPE 1.7° TOTAL ACROSS NEAREST (2) JOINTS BLOWOFF VALVE AT LOW POINT BEGIN 2.5° TOTAL DEFLECTION ACROSS NEXT (3) JOINTS AFTER STA 40+00 BEGIN 1.6° TOTAL DEFLECTION ACROSS NEXT (2) JOINTS AFTER STA 37+25 BEGIN 1.7° TOTAL DEFLECTION ACROSS NEXT (2) JOINTS AFTER STA 35+50 BEGIN 7° TOTAL DEFLECTION ACROSS NEXT (7) JOINTS AFTER STA 33+50 STA = 39+71.70 TOP. = 5208.39' 45° HORIZONTAL BEND STA = 40+32.18 TOP. = 5210.52' AIR/VACCUM VALVE STA = 40+44.47 TOP. = 5210.46' 22.5° HORIZONTAL BEND STA = 35+05.55 TOP = 5200.73' 20" X 8" TEE 20 BFV (E & W) STA = 40+19.47 TOP. = 5210.07' 45° HORIZONTAL BEND JOINT RESTRAINT STA 33+68 TO STA 36+46 1" = 5' WT04 0 30' 60' SCALE: 1" = 30' 15' WATERLINE PLAN & PROFILE N GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. BURY DEPTH ON WATERLINE SHALL BE 5' TO FINISHED GRADE UNLESS OTHERWISE DEPICTED IN THESE DRAWINGS. 2. PRESSURE TEST AND DISINFECT NEW WATERLINE BEFORE CONNECTING TO EXISTING PIPING. 3. FITTINGS ADJACENT TO ONE ANOTHER SHALL BE CONNECTED VIA FOSTER ADAPTER. LEGEND NOTES FIRE HYDRANT WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER MH SANITARY SEWER MH OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE 20" WATERLINE PROFILE SEE SHEET WT05 MATCHLINE STA: 41+50 MATCHLINE STA: 33+50 SEE SHEET WT03 1" = 30' 14 STA = 32+64.91 TOP = 5187.13' VERTICALLY DEFLECT PIPE 1.2° TOTAL ACROSS NEAREST (2) JOINTS STA = 27+50.48 TOP = 5162.69' VERTICALLY DEFLECT PIPE 0.4° TOTAL ACROSS NEAREST (1) JOINT BEGIN 3° TOTAL DEFLECTION ACROSS NEXT (3) JOINTS AFTER STA 31+25 BEGIN 1.2° TOTAL DEFLECTION ACROSS NEXT (2) JOINTS AFTER STA 29+00 BEGIN 0.4° TOTAL DEFLECTION ACROSS NEXT (1) JOINT AFTER STA 27+25 BEGIN 1.2° TOTAL DEFLECTION ACROSS NEXT (2) JOINTS AFTER STA 25+75 BEGIN 1.2° TOTAL DEFLECTION ACROSS NEXT (2) JOINTS AFTER STA 32+25 1" = 5' WT03 0 30' 60' SCALE: 1" = 30' 15' WATERLINE PLAN & PROFILE N GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. BURY DEPTH ON WATERLINE SHALL BE 5' TO FINISHED GRADE UNLESS OTHERWISE DEPICTED IN THESE DRAWINGS. 2. PRESSURE TEST AND DISINFECT NEW WATERLINE BEFORE CONNECTING TO EXISTING PIPING. 3. FITTINGS ADJACENT TO ONE ANOTHER SHALL BE CONNECTED VIA FOSTER ADAPTER. LEGEND NOTES FIRE HYDRANT WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER MH SANITARY SEWER MH OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE 20" WATERLINE PROFILE SEE SHEET WT04 MATCHLINE STA:33+50 MATCHLINE STA: 25+50 SEE SHEET WT02 1" = 30' 13 5160 5165 25+50 25+00 24+50 24+00 23+50 23+00 22+50 22+00 21+50 21+00 20+50 20+00 19+50 19+00 18+50 18+00 17+50 20" PVC WATERLINE 5' MIN BURY DEPTH EXISTING GROUND AT PIPE CENTERLINE JOINT RESTRAINT STA 16+64 TO STA 18+40 STA = 18+25.13 TOP = 5123.75' 11.25° VERTICAL BEND FITTING STA = 21+57.33 TOP = 5132.04' VERTICALLY DEFLECT PIPE 1° TOTAL ACROSS NEAREST (2) JOINTS STA = 18+88.74 TOP = 5124.52' VERTICALLY DEFLECT PIPE 1° TOTAL ACROSS NEAREST (2) JOINTS STA = 18+04.33 TOP = 5119.33' 11.25° VERTICAL BEND FITTING STA = 23+82.53 TOP = 5142.10' VERTICALLY DEFLECT PIPE 1.1° TOTAL ACROSS NEAREST (2) JOINTS BEGIN 1° TOTAL DEFLECTION ACROSS NEXT (1) JOINT AFTER STA 21+50 BEGIN 1.1° TOTAL DEFLECTION ACROSS NEXT (2) JOINTS AFTER STA 23+50 BEGIN 1° TOTAL DEFLECTION ACROSS NEXT (1) JOINT AFTER STA 18+75 STA = 17+85.90 TOP = 5119.28' 11.25° HORIZONTAL BEND STA = 18+19.49 TOP = 5122.54' 11.25° HORIZONTAL BEND STA = 24+03.94 TOP = 5143.48' SERVICE CONNECTION 1" = 5' WT02 0 30' 60' SCALE: 1" = 30' 15' WATERLINE PLAN & PROFILE N GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. BURY DEPTH ON WATERLINE SHALL BE 5' TO FINISHED GRADE UNLESS OTHERWISE DEPICTED IN THESE DRAWINGS. 2. PRESSURE TEST AND DISINFECT NEW WATERLINE BEFORE CONNECTING TO EXISTING PIPING. 3. FITTINGS ADJACENT TO ONE ANOTHER SHALL BE CONNECTED VIA FOSTER ADAPTER. LEGEND NOTES FIRE HYDRANT WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER MH SANITARY SEWER MH OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE 20" WATERLINE PROFILE SEE SHEET WT03 MATCHLINE STA: 25+50 MATCHLINE STA: 17+50 SEE SHEET WT01 1" = 30' 12 INSTALL 20" BFV @ STA 10+05 CLOSE UPON INSTALL SO 36" MAIN CAN BE PUT BACK IN SERVICE N. 1450430.33 E. 3102466.66 STA: 9+50.00 BEGIN ALIGNMENT N. 1450429.79 E. 3102516.67 S79°28'35"E 33.62' N88°21'51"E 80.39' N13°50'50"E 36.20' N23°27'59"E 134.41' S68°06'19"E 206.22' N79°45'24"E 103.24' N54°23'15"E 66.01' S89°22'59"E 159.43' 9+50 10+00 11+00 12+00 13+00 15+00 14+00 16+00 17+00 18+00 20" WATERLINE PROFILE 5100 5105 5110 5115 5120 5125 5130 5135 5140 5145 5150 5100 5105 5110 5115 5120 5125 5130 5135 5140 5145 5150 17+50 17+00 16+50 16+00 15+50 15+00 14+50 14+00 13+50 13+00 12+50 12+00 11+50 11+00 10+50 10+00 9+50 STORMDRAIN CROSSING 18" RCP @ BOP 5124' REMOVE AND REPLACE TO INSTALL WL COMCAST AND FC ELECTRIC 45" BELOW GRADE 12" DIP COFC WATER APPROX 71" BELOW GRADE 5-2", 1-4" WHITE PVC ELEC 35" BELOW GRADE GAS LINE DEPTH AND SIZE UNK FC SANITARY SEWER APPROX INV 5114.24 FT PLASTIC GAS LINE 31" BELOW GRADE COMCAST 14" BELOW GRADE 2-2" ELEC CONDUIT 20" BELOW GRADE CONDUIT AND DIRECT BURY 31" BELOW GRADE 1-4", 3-2" COMCAST/A/V 36" BELOW GRADE 5' MIN BURY DEPTH EXISTING GROUND AT PIPE CENTERLINE 20" PVC WATERLINE 2' CONCRETE PAN JOINT RESTRAINT STA 10+00 TO STA 11+76 JOINT RESTRAINT STA 12+25 TO STA 12+36 JOINT RESTRAINT STA 13+13 TO STA 13+44 JOINT RESTRAINT STA 14+86 TO STA 15+83 JOINT RESTRAINT STA 16+64 TO STA 18+40 MIN 18" SEPARATION STA = 10+00.00 TOP. = 5110.60' CONNECT TO FCLWD WATER LINE WITH 36" X 20" TEE STA = 11+55.15 TOP = 5117.61' 11.25° VERTICAL BEND FITTING COMBINATION AIR/VACUUM VALVE IMMEDIATELY UPSTREAM OF FITTING STA = 11+28.76 TOP = 5112.59' 11.25° VERTICAL BEND FITTING STA = 11+59.56 TOP = 5117.62' 11.25° AND 22.5° HORIZONTAL BENDS STA = 12+25.45 TOP = 5117.80' 22.5° HORIZONTAL BEND STA = 13+28.69 TOP = 5118.07' 11.25° AND 22.5° HORIZONTAL BENDS STA = 15+34.91 TOP = 5118.62' 90° HORIZONTAL BEND STA = 16+69.31 TOP = 5118.98' 11.25° HORIZONTAL BEND STA = 17+05.51 TOP = 5119.07' 22.5° AND 45° HORIZONTAL BENDS STA = 12+96.02 TOP = 5117.99' SAMPLE STATION 1" = 5' WT01 0 30' 60' SCALE: 1" = 30' 15' WATERLINE PLAN & PROFILE N GOLDEN CURRANT WATERLINE REPLACEMENT PREPARED FOR: JOB NUMBER SHEET NUMBER OF SHEETS DATE SUBMITTED: The engineer preparing these plans will not be responsible for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. BURY DEPTH ON WATERLINE SHALL BE 5' TO FINISHED GRADE UNLESS OTHERWISE DEPICTED IN THESE DRAWINGS. 2. PRESSURE TEST AND DISINFECT NEW WATERLINE BEFORE CONNECTING TO EXISTING PIPING. 3. FITTINGS ADJACENT TO ONE ANOTHER SHALL BE CONNECTED VIA FOSTER ADAPTER. LEGEND NOTES FIRE HYDRANT WATER LINE BENDS THRUST BLOCK GATE VALVE PROPOSED UTILITIES 8" WATER LINE WATER SERVICE EXISTING UTILITIES WATER LINE SANITARY SEWER STORM DRAIN PIPE SANITARY SEWER MH SANITARY SEWER MH OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE 20" WATERLINE PROFILE SEE SHEET WT02 MATCHLINE STA: 17+50 1" = 30' 11 HONEYSUCKLE CT. GOLDEN CURRANT CT. PROPOSED FCLWD 20' WATERLINE EASEMENT LEGEND MAPPING / SITE PROPERTY BOUNDARY RIGHT-OF-WAY LOT LINES EASEMENTS CENTER LINE CURB AND GUTTER EXISTING CONTOURS PROPOSED CONTOURS EXISTING UTILITIES WATER LINE MAIN SANITARY SEWER MAIN STORM DRAIN PIPE SANITARY SEWER MANHOLE STORM DRAIN MANHOLE OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE PROPOSED UTILITIES SANITARY SEWER MAIN SANITARY SERVICE SANITARY SEWER MANHOLE WATER LINE MAIN WATER SERVICE FIRE HYDRANT WATER LINE FITTINGS THRUST BLOCK GATE VALVE STORM DRAIN PIPE STORM DRAIN MANHOLE STORM DRAIN INLET FLARED END SECTON RIPRAP 1. MINIMUM HORIZONTAL EDGE TO EDGE SEPARATION BETWEEN SANITARY & WATERLINES IS 10 FEET. 2. WATER MAINS CROSSING OVER A SANITARY OR STORM SEWER SHALL MAINTAIN AN 18" VERTICAL EDGE TO EDGE CLEARANCE. WATER MAINS CLOSER THAN 18" OR UNDER SEWERS SHALL BE DISCUSSED WITH THE ENGINEER. 3. MINIMUM COVER ON WATERLINES IS 5.0 FEET UNLESS OTHERWISE SHOWN ON THIS PLAN. 4. ALL EXISTING UTILITIES TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTES PROPOSED FCLWD 50' TEMPORARY CONSTRUCTION EASEMENT EXISTING FCLWD 8" WATERLINE (TO BE ABANDONED, SEE SHEET AB01) CONNECT TO EXISTING 36" FCLWD WATER MAIN SOUTH - 8" GATE VALVE AND 8"X6" REDUCER. INSTALL 199 LF OF 6" PVC PIPE TO CONNECT TO 6" LINE WITH 6" TRANSITION COUPLER CATALPA CT CROSSING UNDER FORT COLLINS 24" WATERLINE CITY OF FORT COLLINS TANK ACCESS ROAD PROPOSED FCLWD 20' WATERLINE EASEMENT EXISTING FCLWD 16" WATERLINE (TO BE ABANDONED, SEE SHEET AB01) CONSTRUCTION DISTURBANCE MUST BE CONTAINED WITHIN THE 50' CONSTRUCTION EASEMENT. ACCESS TO THE TANK TO BE MAINTAINED AT ALL TIMES. LEGEND MAPPING / SITE PROPERTY BOUNDARY RIGHT-OF-WAY LOT LINES EASEMENTS CENTER LINE CURB AND GUTTER EXISTING CONTOURS PROPOSED CONTOURS EXISTING UTILITIES WATER LINE MAIN SANITARY SEWER MAIN STORM DRAIN PIPE SANITARY SEWER MANHOLE STORM DRAIN MANHOLE OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE PROPOSED UTILITIES SANITARY SEWER MAIN SANITARY SERVICE SANITARY SEWER MANHOLE WATER LINE MAIN WATER SERVICE FIRE HYDRANT WATER LINE FITTINGS THRUST BLOCK GATE VALVE STORM DRAIN PIPE STORM DRAIN MANHOLE STORM DRAIN INLET FLARED END SECTON RIPRAP 1. MINIMUM HORIZONTAL EDGE TO EDGE SEPARATION BETWEEN SANITARY & WATERLINES IS 10 FEET. 2. WATER MAINS CROSSING OVER A SANITARY OR STORM SEWER SHALL MAINTAIN AN 18" VERTICAL EDGE TO EDGE CLEARANCE. WATER MAINS CLOSER THAN 18" OR UNDER SEWERS SHALL BE DISCUSSED WITH THE ENGINEER. 3. MINIMUM COVER ON WATERLINES IS 5.0 FEET UNLESS OTHERWISE SHOWN ON THIS PLAN. 4. ALL EXISTING UTILITIES TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTES PROPOSED 20' EASEMENT PROPOSED 20' EASEMENT PROPOSED FCLWD 50' TEMPORARY CONSTRUCTION EASEMENT PROPOSED 20' EASEMENT PROPOSED 50' CONSTRUCTION EASEMENT OHE FORT COLLINS NATURAL AREA / HOA OPEN SPACE PROPERTY BOUNDARY WEST SIDE OF PROPOSED CONSTRUCTION EASEMENT FOLLOWS PROPERTY BOUNDARY IN THIS AREA EXISTING FCLWD EASEMENT SANITARY SEWER MANHOLE WATER LINE MAIN WATER SERVICE FIRE HYDRANT WATER LINE FITTINGS THRUST BLOCK GATE VALVE STORM DRAIN PIPE STORM DRAIN MANHOLE STORM DRAIN INLET FLARED END SECTON RIPRAP 1. MINIMUM HORIZONTAL EDGE TO EDGE SEPARATION BETWEEN SANITARY & WATERLINES IS 10 FEET. 2. WATER MAINS CROSSING OVER A SANITARY OR STORM SEWER SHALL MAINTAIN AN 18" VERTICAL EDGE TO EDGE CLEARANCE. WATER MAINS CLOSER THAN 18" OR UNDER SEWERS SHALL BE DISCUSSED WITH THE ENGINEER. 3. MINIMUM COVER ON WATERLINES IS 5.0 FEET UNLESS OTHERWISE SHOWN ON THIS PLAN. 4. ALL EXISTING UTILITIES TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTES SEE SHEET UT02 SEE SHEET UT03 GOLDEN CURRANT BLVD CATALPA CT HONEYSUCKLE CT REEDGRASS CT WEST PROSPECT ROAD GOLDEN CURRANT CT BANYAN DRIVE OVERLAND TRAIL LEGEND MAPPING / SITE PROPERTY BOUNDARY RIGHT-OF-WAY LOT LINES EASEMENTS CENTER LINE CURB AND GUTTER EXISTING CONTOURS PROPOSED CONTOURS EXISTING UTILITIES WATER LINE MAIN SANITARY SEWER MAIN STORM DRAIN PIPE SANITARY SEWER MANHOLE STORM DRAIN MANHOLE OVERHEAD ELECTRIC GAS LINE ELECTRIC LINE PROPOSED UTILITIES SANITARY SEWER MAIN SANITARY SERVICE SANITARY SEWER MANHOLE WATER LINE MAIN WATER SERVICE FIRE HYDRANT WATER LINE FITTINGS THRUST BLOCK GATE VALVE STORM DRAIN PIPE STORM DRAIN MANHOLE STORM DRAIN INLET FLARED END SECTON RIPRAP 1. MINIMUM HORIZONTAL EDGE TO EDGE SEPARATION BETWEEN SANITARY & WATERLINES IS 10 FEET. 2. WATER MAINS CROSSING OVER A SANITARY OR STORM SEWER SHALL MAINTAIN AN 18" VERTICAL EDGE TO EDGE CLEARANCE. WATER MAINS CLOSER THAN 18" OR UNDER SEWERS SHALL BE DISCUSSED WITH THE ENGINEER. 3. MINIMUM COVER ON WATERLINES IS 5.0 FEET UNLESS OTHERWISE SHOWN ON THIS PLAN. 4. ALL EXISTING UTILITIES TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTES 3. EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 4. IN ADDITION TO THE EROSION CONTROL MEASURES SHOWN ON THIS DRAWING, THE CONTRACTOR SHALL COMPLETE, COORDINATE WITH, AND UPDATE AS REQUIRED, THE STORMWATER POLLUTION PREVENTION PLAN (SWPP) FOR THIS PROJECT. 5. ANY AREAS USED FOR STOCKPILING AND/OR STAGING SHOULD ALSO HAVE SEDIMENT AND EROSION CONTROL MEASURES AS NECESSARY. THESE AREAS SHOULD BE LOCATED AT LEAST 100' AWAY FROM DRAINAGE WAYS. THE SWMP SHOULD BE UPDATED TO SHOW THESE AREAS AND SEDIMENT AND EROSION CONTROL ITEMS. THE ITEMS MAY INCLUDE BUT ARE NOT LIMITED TO VEHICLE TRACKING CONTROL, SILT FENCE, CONSTRUCTION FENCE, CONCRETE WASHOUT, AND SEDIMENT TRAP. 6. CONTRACTOR SHALL REMOVE ALL SEDIMENT, MUD, CONSTRUCTION DEBRIS, OR OTHER POTENTIAL POLLUTANTS THAT MAY HAVE BEEN DISCHARGED TO OR, ACCUMULATE IN, THE FLOW LINES AND PUBLIC RIGHTS-OF-WAY OF THE CITY, AS A RESULT OF CONSTRUCTION ACTIVITIES ASSOCIATED WITH THIS DEVELOPMENT OR CONSTRUCTION PROJECT. SAID REMOVAL SHALL BE CONDUCTED DAILY, AS MAY BE REQUIRED. SUCH MATERIALS SHALL BE PREVENTED FROM ENTERING THE STORM SEWER. NOTES LEGEND MAPPING / SITE PROPERTY BOUNDARY RIGHT-OF-WAY LOT LINES EASEMENTS CENTER LINE CURB AND GUTTER EXISTING CONTOURS PROPOSED CONTOURS STORM DRAIN PIPE STORM INLET SILT FENCE SLOPE PROTECTION VEHICLE TRACKING CONTROL PAD WATTLE DIKE ROCK SOCK TEMPORARY SEDIMENT INLET PROTECTION TURF REINFORCEMENT MAT EROSION 1. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE FIELD CONDITIONS ARE AS SHOWN IN THE DRAWINGS. IF THE CONTRACTOR FINDS DISCREPANCIES THE CONTRACTOR SHALL CONTACT THE ENGINEER. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR NECESSARY TEMPORARY RE-VEGETATION DURING CONSTRUCTION AND THROUGH SUBSTANTIAL COMPLETION. 3. EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 4. IN ADDITION TO THE EROSION CONTROL MEASURES SHOWN ON THIS DRAWING, THE CONTRACTOR SHALL COMPLETE, COORDINATE WITH, AND UPDATE AS REQUIRED, THE STORMWATER POLLUTION PREVENTION PLAN (SWPP) FOR THIS PROJECT. 5. ANY AREAS USED FOR STOCKPILING AND/OR STAGING SHOULD ALSO HAVE SEDIMENT AND EROSION CONTROL MEASURES AS NECESSARY. THESE AREAS SHOULD BE LOCATED AT LEAST 100' AWAY FROM DRAINAGE WAYS. THE SWMP SHOULD BE UPDATED TO SHOW THESE AREAS AND SEDIMENT AND EROSION CONTROL ITEMS. THE ITEMS MAY INCLUDE BUT ARE NOT LIMITED TO VEHICLE TRACKING CONTROL, SILT FENCE, CONSTRUCTION FENCE, CONCRETE WASHOUT, AND SEDIMENT TRAP. 6. CONTRACTOR SHALL REMOVE ALL SEDIMENT, MUD, CONSTRUCTION DEBRIS, OR OTHER POTENTIAL POLLUTANTS THAT MAY HAVE BEEN DISCHARGED TO OR, ACCUMULATE IN, THE FLOW LINES AND PUBLIC RIGHTS-OF-WAY OF THE CITY, AS A RESULT OF CONSTRUCTION ACTIVITIES ASSOCIATED WITH THIS DEVELOPMENT OR CONSTRUCTION PROJECT. SAID REMOVAL SHALL BE CONDUCTED DAILY, AS MAY BE REQUIRED. SUCH MATERIALS SHALL BE PREVENTED FROM ENTERING THE STORM SEWER. NOTES LEGEND MAPPING / SITE PROPERTY BOUNDARY RIGHT-OF-WAY LOT LINES EASEMENTS CENTER LINE CURB AND GUTTER EXISTING CONTOURS PROPOSED CONTOURS STORM DRAIN PIPE STORM INLET SILT FENCE SLOPE PROTECTION VEHICLE TRACKING CONTROL PAD WATTLE DIKE ROCK SOCK TEMPORARY SEDIMENT INLET PROTECTION TURF REINFORCEMENT MAT EROSION INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 5. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS AND PONDS AT OVERLAND TRAIL HOA (ON-SITE MANAGEMENT: (970) 282-8281) PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 6. LIMITS OF DISTURBANCE ARE ASSUMED TO BE UP TO APPROXIMATELY 25-FEET TO EITHER SIDE OF THE PROPOSED UTILITY ALIGNMENT UNLESS OTHERWISE SHOWN ON THESE PLANS. 7. AREAS WITHIN LIMIT OF DISTURBANCE WITHOUT SPECIFIC REMOVAL/REPLACEMENT DIRECTIONS SHALL BE RE-SEEDED WITH SEED MIX AS DIRECTED IN GENERAL NOTES. LEGEND NOTES LOT LINES EASEMENT LINES CENTERLINE EXISTING MAPPING AND SITE CURB AND GUTTER INTERMEDIATE CONTOUR INDEX CONTOUR EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. WATER VALVE FIRE HYDRANT ELECTRIC POLE WATER / SANITARY PLUG WATER METER WATER VAULT FENCE PROPERTY BOUNDARY RIGHT-OF-WAY 5078 5080 REMOVE & DISPOSE OF EXISTING CONCRETE DITCH REMOVE EXISTING CURB & GUTTER & SIDEWALK SAWCUT LINE REMOVE EXISTING ASPHALT LIMITS OF DISTURBANCE REMOVALS ELECTRIC LINE OVERHEAD ELECTRIC LINE FIBER, GAS, ELECTRIC, OR TELEPHONE PEDESTALS REMOVE EXISTING CONCRETE REMOVE AND REPLACE EXISTING GRASS / SOD REMOVE AND REPLACE EXISTING UTILITY PIPING REMOVE AND REPLACE EXISTING TREE REMOVE AND REPLACE DIRT ROAD AND PATH N N 0 30' 60' SCALE: 1" = 30' 15' 4 for, or liable for, unauthorized changes to or uses of these plans. All changes to the plans must be in writing and must be approved by the preparer of these plans. NO. BY DATE CAUTION REVISIONS: VERTICAL: HORIZONTAL: SCALE PROJ. MGR: DRAWING NAME: PATH: DATE: TIME: DESIGNER: FCLWD 09/11/2020 C18015 20 4025 Automation Way Suite B2 Fort Collins, CO 80525 (970) 698-6046 9/11/20 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, PAVEMENT, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. CURB, GUTTER, SIDEWALK, AND CONCRETE PANS SHALL BE REMOVED TO THE NEAREST JOINT. 4. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 5. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS AND PONDS AT OVERLAND TRAIL HOA (ON-SITE MANAGEMENT: (970) 282-8281) PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 6. LIMITS OF DISTURBANCE ARE ASSUMED TO BE UP TO APPROXIMATELY 25-FEET TO EITHER SIDE OF THE PROPOSED UTILITY ALIGNMENT UNLESS OTHERWISE SHOWN ON THESE PLANS. 7. AREAS WITHIN LIMIT OF DISTURBANCE WITHOUT SPECIFIC REMOVAL/REPLACEMENT DIRECTIONS SHALL BE RE-SEEDED WITH SEED MIX AS DIRECTED IN GENERAL NOTES. LEGEND NOTES LOT LINES EASEMENT LINES CENTERLINE EXISTING MAPPING AND SITE CURB AND GUTTER INTERMEDIATE CONTOUR INDEX CONTOUR EXISTING UTILITIES WATER LINE SANITARY SEWER W SS STORM DRAIN PIPE SANITARY SEWER M.H. STORM SEWER M.H. WATER VALVE FIRE HYDRANT ELECTRIC POLE WATER / SANITARY PLUG WATER METER WATER VAULT FENCE PROPERTY BOUNDARY RIGHT-OF-WAY 5078 5080 REMOVE & DISPOSE OF EXISTING CONCRETE DITCH REMOVE EXISTING CURB & GUTTER & SIDEWALK SAWCUT LINE REMOVE EXISTING ASPHALT LIMITS OF DISTURBANCE REMOVALS ELECTRIC LINE OVERHEAD ELECTRIC LINE FIBER, GAS, ELECTRIC, OR TELEPHONE PEDESTALS REMOVE EXISTING CONCRETE REMOVE AND REPLACE EXISTING GRASS / SOD REMOVE AND REPLACE EXISTING UTILITY PIPING REMOVE AND REPLACE EXISTING TREE REMOVE AND REPLACE DIRT ROAD AND PATH 3 by law, the engineer hereby agrees to hold harmless and indemnify the Local Entity, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All sanitary sewer, storm sewer, and water line construction, as well as power and other “dry” utility installations, shall conform to the Local Entity standards and specifications current at the date of approval of the plans by the Local Entity Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Engineer shall contact the Utility Notification Center of Colorado (UNCC) at 1- 800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the Local Entity prior to beginning construction. 10. The Developer shall coordinate and cooperate with the Local Entity, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The Local Entity shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the Local Entity, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The Local Entity shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the Local Entity failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the final drainage and erosion control study, if applicable, shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the Local Entity street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the Local Entity Engineering Inspector (Fort Collins - 221-6605) and the Local Entity Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the Local Entity Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the Local Entity reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right- of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the Local Entity's default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the Local Entity Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the Local Entity inspector. The engineer or surveyor must certify in a letter to the Local Entity that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the Local Entity before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County FloodPlain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact Local Entity Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor; however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the Local Entity Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the Local Entity. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the Local Entity Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Local Entity's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the Local Entity Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: Benchmarks--Local Entity survey. B.M.Number 32-92,Elev.=5119.42 NAVD88, Description COFCBM: NORTHEAST CORNER OF LAKE ST. AND OVERLANDTRAIL, IN THE EAST HEADWALL OF THE BRIDGE OVER THE PLEASANT VALLEY AND LAKE CANAL. GENERAL NOTES CONTINUED 41. All stationing is based on centerline of the pipe unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Local Entity Construction Inspector before any cuts are made. Patching shall be done in accordance with the Local Entity Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Local Entity Engineer and/or the Local Entity Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all “T” intersections. 46. After acceptance by the Local Entity, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The Local Entity shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: (list). N/A 48. Approved Variances are listed as follows: (Plan set must have a list of all applicable variances for the project). N/A CITY OF FORT COLLINS GRADING AND EROSION CONTROL NOTES 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights- of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the Local Entity. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall clean up any inadvertent deposited material immediately and make sure streets are free of all materials by the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the Local Entity or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. To ensure that sediment does not move off of individual lots one or more of the following sediment/erosion control BMPs shall be installed and maintained until the lots are sufficiently stabilized, as determined by the erosion control inspector, (Within Loveland GMA and City Limits Only). a. Below all gutter downspouts. b. Out to drainage swales. c. Along lot perimeter. d. Other locations, if needed. 16. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City/County. 17. A vehicle tracking control pad shall be installed when needed for construction equipment, including but not limited to personal vehicles exiting existing roadways. No earthen materials, i.e. stone, dirt, etc. shall be placed in the curb & gutter or roadway as a ramp to access temporary stockpiles, staging areas, construction materials, concrete washout areas, and/or building sites. SEED MIX 1. The city of Fort Collins' upland native seed mix should be used for this site. The seed mix details can be found on page DT02 of this plan set. FORT COLLINS LOVELAND WATER DISTRICT NOTES 1. This project shall be constructed to the most current edition (June 2010, revision 2.0) of the Fort Collins-Loveland Water District Standards and Specifications unless indicated otherwise on these plans. 2. Waterlines should have 5 to 6 ft of cover unless otherwise noted on the construction plans. 3. Waterlines should have 18 inches vertical separation from all other utilities. If 18" of clearance is not possible, contact the district engineer to discuss alternatives. 4. Maximum deflection of 20-foot lengths of of 20" C900 PVC pipe shall be approximately 4.2" (1.0 degrees) at the joint. 5. Individual lengths of 20" C900 PVC pipe shall not be longitudinally bent (i.e. no barrel bending). 6. All waterlines shall be installed with tracer wire. 7. Contractor shall grade the project through substantial completion, including trench backfill and designed finished grade. 8. Contractor is responsible for any necessary temporary re-vegetation during construction and through substantial completion. 2 OFFICE PHONE: 970-232-9645 CONTACT: CHAD WASHBURN, PLS CELL PHONE: 970-685-8836 PROJECT TEAM PROSPECT RD OVERLAND TRAIL PROFESSIONAL ENGINEER CERTIFICATION THESE CONSTRUCTION PLANS FOR THE FORT COLLINS LOVELAND WATER DISTRICT - GOLDEN CURRANT WATER LINE WERE PREPARED BY ME (OR UNDER MY DIRECT SUPERVISION) IN ACCORDANCE WITH THE REQUIREMENTS OF THE ROAD STANDARDS AND THE STORMWATER DESIGN STANDARDS FOR LARIMER COUNTY, AND THE FORT COLLINS LOVELAND WATER DISTRICT DESIGN CRITERIA. AUSTIN SNOW, PE CIVILWORX, LLC REQUIRED PERMITS BY CONTRACTOR CITY OF FORT COLLINS NATURAL AREAS - RIGHT OF WAY CONSTRUCTION PERMIT CITY OF FORT COLLINS ENGINEERING - TRAFFIC CONTROL PLAN COLORADO DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT - CONSTRUCTION DEWATERING PERMIT - PERMIT FOR STORMWATER DISCHARGE FORT COLLINS-LOVELAND WATER DISTRICT - PRE-CONSTRUCTION MEETING CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. Call before you dig. R 1" = N/A 9/11/2020 8:11:51 AM D:\CIVILWORX DROPBOX\CIVILWORX\PROJECTS\C18015 - FCLWD GOLDEN CURRANT\C18015 - FCLWD GOLDEN CURRANT - CADD\CP\CX.XX_COVER SHEET.DWG CX.XX_COVER SHEET ## ## CS01 COVER SHEET ELIZABETH ST All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT 1 10/16/20