HomeMy WebLinkAboutBURNS RANCH AT QUAIL RIDGE AMENDED RF SITE PLAN - 23 90D - CORRESPONDENCE - STAFF'S PROJECT COMMENTSr
Commilty Planning and Environment rvices 1e
Planning Department
February 19, 1993
Eldon Ward
c/o Cityscape Urban Design
3555 Stanford Road Suite 105
Fort Collins, CO 80525
Dear Mr. Ward,
City Staff has reviewed your submittal for Burns Ranch at Quail
Ridge Amended RF Cluster Plan and offers the following written
comments:
1. Minimum setbacks in an RF cluster- plan cannot vary from those
required in the RL District, without a variance from the ZBA,
Zoning Board of Appeals. Therefore any reference to setbacks
should state exactly what the RL Zone allows.
2. Show the tracts on the Landscape/Site Plan. They should
correspond to the tracts on the plat. Place a note on the
plat and site plan explaining the purpose of the tracts.
3. The City will not accept Tract B as open space.
4. Obtain permission from WAPA for trail access across their
easement prior to final approval and public use of the
easement prior to the City accepting the open space. Please
provide a letter for the files to this effect.
5. The City Forester will review the proposed landscaping in the
open space tracts and his comments will be forwarded to you.
6. Phase 2 exceeds the 660' distance for a dead-end cul-de-sac.
The proposed emergency access road has been discussed and
would only be allowed to function as emergency access if it is
maintained year round and meets all other access road
criteria.
7. Parks and Recreation is interested in sharing the cost of a
trail/emergency access road from Overland Trail to the
Pineview Open Space area if an alignment can be agreed upon.
8. There should be a note on the plans stating that houses in the
second filing must have automatic fire sprinkler systems
installed prior to certificate of occupancy, or that an access
road will be constructed prior to the issuance of any building
permits. The District requires a separate 1" tap for fire
sprinkler systems.
281 North Colle-e AVenue • l'.Q. Box DSO • Fort Collins, Co 50_:;'..=-0 S0 (1031 221-67;0
0 0
9: Please refer to the attached comments from US West.
10. Refer to the Utility Plans for comments from the Water and
Wastewater Utility.
11. Planting of trees in the open space tracts on Nesbit Court and
the at the south end of Skimmerhorn Street needs to be
coordinated with Public Service Company. Maintain a minimum
clearance of 4' between trees and gas main installations..
12. The Utility Plan does not show water service locations for
each lot. Location of water services will need to be
coordinated with Light and Power before water installation.
The developer should contact Light and Power if three phase
power is required.
13. Columbine CableVision would like to have Tracts A, B, C (on
the plat) changed to Open Space and Utility Easements. If you
have questions about this request, please contact Dennis
Greenwalt at Columbine CableVision. Easements across the open
space areas to connect the back yard easements may satisfy
their concerns.
14. Columbine CableVision would also like to see the homes wired
in a Home Run System with cable meeting Columbine's standards.
15. Sidewalk is required on both sides of the public streets. •Lot
sizes and configuration do not meet the City's rural street
standard criteria. The lots in phase 1 were configured in
such a way that sidewalks on 1 side, etGe2o!/ouee�.
16. Nesbit Court should be designed to carry 2% slope further
back. You can go to 8% street slope if necessary.
17. Please provide a pavement design and reference soils report.
18. We will double check note #4 with Light and Power.
v,
19. How was the south line of the N..E. 1/4 (the south line of the
plat) determined on the plat?
20. The triangular piece of right-of-way at the northeast corner
of the property will have to be platted with the.2nd filing.
In order to put a sign on the tract it will have to be
platted. A note should be added to the plans to discuss
maintenance and ownership of this tract (is this entire tract
public ROW).
21. Final drainage comments will be sent under separate cover.
This concludes staff comments at this time. In order to stay on
schedule for the March 22, 1993 Planning and Zoning Board hearing,
please note the following deadlines:
0 0
Plan revisions are due March 3, 1993 by 12:06 noon.
PMT's, colored renderings, and 10 prints are due March 15.
Final mylars and other documents are due March 18th by 12:00.
Please be aware that the development agreement and utility
Plans for Planned Unit Developments (PUD's):must be signed
prior to the Planning and Zoning Board Hearing. If not, a
condition will be placed on the project giving you 30 days to
finalize the plans and agreement, after which time, you must
submit a request for an extension from the Planning and Zoning
Board.
If you have any questions about these comments or would like to
schedule a time to meet to discuss them, please contact me at 22.1-
6750.
Sincerely,
Kirsten Whetstone
Project Planner
cc Kerrie Ashbeck, Engineering
RBD Engineering
PROJECT
COMMENT SHEET
DATE: 1 Feb 1993 DEPARTMENT:
ENT:
ITEM: 23-90D BURNS RANCH AT QUAIL RIDGE AMENDED/2ND
Please respond to this project by Friday, February 12,1993
Planner: Kirsten Whetstone
Note: This is an RF site plan review, with a final subdivision plat.
No Problems
_ Problems or Concerns (see below)
Review of these plans should not be construed as a commitment
that telephone facilities sufficient to serve this project are
presently available. U S WEST will provide telephone service in
accordance with the rates and tariffs on file with the Colorado
Public Utilities Commission.
Telephone facilities generally occupy rear lot utility easements,
which must be located on terrain which permits trenching
operations. U S WEST would require an easement across Tract C
between the rear corners of Lots 2 & 3, across Tract B from the
southwest corner of Lot 26 to the northeast corner of Lot 24, and
across Tract A from the northwest corner of Lot 17 to a point
straight west on the east property line of Lot 19.
The developer is responsible for provision of all trench and
street crossings for telephone facilities within the project, and
the developer pays up front construction costs for facilities
within the development.
Any relocation of existing telephone facilities required by these
plans will be paid for by the developer.
Date: Signature.�
CHE REVISIONS REQUIRED: PLAT
❑ SITE
❑ LANDSCAPE
❑ UTILITY
DEVELOPMENT SERVICES 291 NORTH COLLEGE P.OXOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221fi750
PLANNING DEPARTMENT