HomeMy WebLinkAboutONE PROSPECT PUD PRELIMINARY - 17 90 - CORRESPONDENCE - CORRESPONDENCE-CONCEPTUAL REVIEWDeveldeent Services
Planning Department
April 10, 1990
W.W. Reynolds Company
c/o Eldon Ward
Cityscape Urban Design
3030 South College Avenue
Fort Collins, CO 80525
Dear Eldon:
For your information, attached is a copy of the Staff's comments concerning
Prospect Park East, Lots 1,2„ 13-16 which was presented before the Conceptual
Review Team on April 9, 1990.
The comments are offered informally by Staff to assist you in preparing the
detailed components of the project application. Modifications and additions to
these comments may be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in
the review process, please feel free to call me at 221-6750.
Sincerely,
Ted Shepard
Project Planner
TS/gjt
Attachment
xc: Tom Peterson, Director of Planning
Mike Herzig, Development Coordinator
Kerrie Ashbeck, Civil Engineer I
Project Planner
File
300 LaPorte Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750
CONCEPTUAL REVIEW STAFF COMMENTS
MEETING DATE: April 9, 1990
ITEM: Prospect Park East, Lots 1,2, 13 - 16
APPLICANT:
W.W. Reynolds Company, c/o Eldon Ward, Cityscape Urban Design, 3030 South
College Ave., Suite 200, Fort Collins, CO. 80525.
LAND USE DATA:
Request for P.U.D. for two buildings totalling 89,600 square feet on
approximately 7.5 acres, located at the southeast corner of East Prospect Road
and Specht Point Road.
COMMENTS:
1. The City Light and Power Department has three phase electrical power
available on all sides except Prospect Road. Please be aware that there is
a buried electrical duct bank along the Prospect Road frontage.
2. According to Light and Power Department records, the first half of the
development charges have already been paid on this property. This
payment was $20,560 made in November of 1984. The second half is due
before the system is energized.
3, Any modifications or alterations to existing Light and Power facilities will
be at the developer's expense.
4. Water mains are available all around the site. There are a combination of
water services and fire lines available to the site. Any combination of
taps may be used for water service or irrigation. Any services not used
must be abandoned at the main.
5. The sewer main presents a unique problem. There must be adequate
clearance for the sewer main that bisects the property from Prospect
Parkway to Specht Point Road, Although the Water Department typically
requires a 20 foot easement for a sewer line, this distance must be
sufficient to use equipment, store dirt, and do whatever is necessary to
repair a busted line. All this must be accomplished without damaging
foundations for which the City could be liable. Please verify the depth of
this line. If it is somewhat shallow, 20 feet may work. If it is deep; 20
feet may not. work.
6. The site is in an area classified by F.E.M.A. as 'overflow". This means
that first floor elevations must be 18 inches above the height of the base
flood elevation. The Drainage Report must account for offsite flows.
Plant material may be allowed in the drainage channels but should not be
massive so that they restrict storm flows.
7. Sidewalks, curbs, and gutters must be installed along all frontages. Since
there is an existing utility plan, this plan may either be revised or a new
plan submitted. Such plan shall show water and sewer modifications,
sidewalks, driveway modifications, street patches, or overlays.
8. The replat will be very simple to review if accompanied by a P.U.D. Be
sure to use appropriate language to vacate unused easements. All new
easements must be dedicated.
9. The Poudre Fire Authority cautions that any floor areas containing more
than 5,000 square feet must be equipped with a fire sprinkler system.
When determining fire access, Prospect koad cannot be used as this is an
arterial street. The parking lot may be used for access if there are the
minimum required turning radii for fire equipment. Since "flex space"
may be subject to change due to tenant demands, it is suggested that the
buildings be equipped with fire sprinklers at the time of construction.
10. The site plan should indicate bicycle, motorcycle, and handicap parking.
11. The interior parking areas should be landscaped with approximately 6% of
the total paved area.
12. Please confirm with Matt Bakery City Engineer, at 221-6605 regarding the
classification for the Street Oversizing Fee.
13. Any combined preliminary and final P.U.D. submittal must be accompanied
by a complete set of plans satisfying the requirements of both the
Planning and Engineering departments. Failure to supply complete plans
may result in splitting the submittal and placing only the preliminary on
the hearing until final plans have been submitted and reviewed.