HomeMy WebLinkAboutFIRE STATION NO 10 PUD PRELIMINARY AND FINAL - 58 92 - CORRESPONDENCE - RESPONSE TO STAFF REVIEW COMMENTSNovember 25, 1992
City of Fort Collins
Planning Department
Attn: Steve Olt
P.O. Box 580
Fort Collins, CO 80522
Dear Steve:
VAUGHT
FRYE
architects
Thank you for your comments on our preliminary/final submittal of the Fire Station 10 P.U.D..
The following response corresponds numerically to the comments contained in your letter
dated November 13, 1992.
1. O.K.
2. Based on our calculations, we would prefer to locate the transformer at the current
southwest location close to the electric room. This would avoid excessive cost on the
secondary side, which is estimated to be seven times the cost of the primary charge.
3. The sand/oil separator will be connected to the sanitary sewer
4. All drainage and erosion control studies have been submitted to date.
5. RBD has updated the drawings.
6. The Austrian pines will be replaced by Honeylocust trees.
7. This has been changed on the Landscape Plan.
8. This has been changed on the Landscape Plan.
9. Poudre Fire Authority will not allow any planting that will interfere with emergency access.
10. Additional planting has been added to the Landscape Plan.
11. O.K.
12. The Elevations have been changed to add building material colors. The maximum
building height is noted in General Note #3 on the Site Plan.
13. Please see attached cut sheets on site lighting. The I.D. sign will be constructed of
stucco and brick to match the building and will be ground lit.
Please let us know if you have any further issues regarding this project.
Sincerely,
Ca,�h, y ma.t{uo
Cathy Mathis
cc: Gene Chantler
Steve White
land planning • architecture
1113 Stoney Hill Drive • Fort Collins, Colorado 80525 • 303-224-1191 • FAX 303-224-1662
n
Annapolis
Square
Product
Information
1. Series Code
AS
2. Bollard Height
30
36
42 — standard
48
3. Diffuser Code
G — Clear Smooth Polycarbonate
(Note for lamps wet 100 walls. a Teflon- enclosure with
expanded metal holder Is furnished)
4. Bollard Options Code
BB — 90' of Louvers Removed
DID — Uplight — Clear Tempered
Glass in Top Cap
CL — Cast Aluminum Louvers
EE — Rings for Chain Support
FF — 900 Internal Shield
GG — 180' Internal Shield
PC — Photoelectric Control
Q — Single Weatherproof
Receptacle
T — Duplex Weatherproof
Receptacle
GFT — Duplex Ground Fault
Receptacle
N — Options Not Required
42•
top uap
cast aluminum
Louver
Alignment Rod
Diffuser
dear poly -
carbonate
.Louver
high -impact
polycarbonate
Lamp
(by others)
Housing
extruded aluminum
8" Sq. x .188' wall
Internal
Tie Rod (2)
Ballast
Components
. Anchor Bolts (4)
Wx18"on
4.5' bolt circle
Wattage: Up to 150 watts for incan-
descent lamps; up to 175 watts for
HID
Bollard size: 8° x 8" x .188" thick wall
Heights: 42" overall -standard; also
available at 30", 36", and 48"
Special features: Full perimeter
polycarbonate louvers shield the light
source and direct light downward in a
circular pattern • Cast aluminum top
cap is sealed and secured with
tamper -proof screw • Interior tie -rod
construction increases strength and
eliminates external fasteners • Lou-
vers available with sections removed
to expose diffuser 90' • Clear tem-
pered glass lens in cast aluminum top
cap available for uplight • Electrostat-
ically applied finishes available in a
wide range of colors
For how -to -order instructions,
see fold -out p.12.
6
O ) l
i) �