Loading...
HomeMy WebLinkAboutCOUNTRY CLUB RESERVE - FDP180030 - DOCUMENT MARKUPS - ROUND 5 - STREET RELATED DOCUMENT5070 5075 5080 5085 5090 5095 5070 5075 5080 5085 5090 5095 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 -2.20% 2.20% -2.50% -2.00% -0.60% 2.00% 0.60% PVI STA = 10+00.00 PVI ELEV = 5083.73 PVI STA = 10+13.83 PVI ELEV = 5083.42 PVI STA = 18+35.68 PVI ELEV = 5076.71 PVI STA = 18+18.85 PVI ELEV = 5076.29 PVI STA = 10+16.83 PVI ELEV = 5083.31 PVI STA = 10+19.83 PVI ELEV = 5083.42 PVI STA = 18+15.85 PVI ELEV = 5076.40 50.0' VC PVI STA = 10+69.83 PVI ELEV = 5084.42 BVCS: 10+44.83 BVCE: 5083.92 EVCS: 10+94.83 EVCE: 5084.57 A.D. = 1.40 K = 35.71 95.0' VC HP ELEV = 5084.78 HP STA = 11+37.55 PVI STA = 11+66.66 PVI ELEV = 5085.01 BVCS: 11+19.16 BVCE: 5084.72 EVCS: 12+14.16 EVCE: 5083.82 A.D. = 3.10 K = 30.65 50.0' VC PVI STA = 17+65.85 PVI ELEV = 5077.40 BVCS: 17+40.85 BVCE: 5077.55 EVCS: 17+90.85 WINGED FOOT DR. SEE SHEET R3 CARNOUSTIE DR. SEE SHEET R5 ROYAL TROON AVE. P P WINGED FOOT DR. SEE SHEET R3 30' - 53' R.O.W 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 7 LOT 6 LOT 5 LOT 8 LOT 10 LOT 9 LOT 11 LOT 13 LOT 13 LOT 14 LOT 22 LOT 21 LOT 12 LOT 23 LOT 20 LOT 5 LOT 4 LOT 2 LOT 3 TRACT E ACCESS & DRAINAGE EASEMENT BLOCK 6 BLOCK 5 BLOCK 9 LOT 3 LOT 4 LOT 2 LOT 1 LOT 12 LOT 11 BLOCK 10 6' PAN R20' R20' R20' R20' 6' UTILITY EASEMENT (TYP.) 5' DRAINAGE AND GRADING EASEMENT (TYP.) 10' MID-BLOCK PAN 31" DRIVE-OVER CURB AND GUTTER 5065 5070 5075 5080 5085 5090 5065 5070 5075 5080 5085 5090 23+50 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 32+50 5075.82 5075.59 5076.22 5076.82 5077.42 5078.02 5079.86 5083.35 5076.04 5075.54 5075.14 5075.25 5075.77 5075.92 5076.07 5076.37 5076.52 5076.67 5076.97 5077.12 5077.27 5077.57 5077.72 5077.87 5078.21 5078.58 5079.13 5080.73 5081.60 5082.48 5084.23 5085.10 5085.83 2.20% 3.50% -0.90% 0.60% PVI STA = 31+77.42 PVI ELEV = 5085.88 PVI STA = 31+63.58 PVI ELEV = 5085.58 PVI STA = 24+59.27 PVI ELEV = 5074.94 50.0' VC PVI STA = 24+29.26 PVI ELEV = 5075.55 BVCS: 24+04.26 BVCE: 5075.78 EVCS: 24+54.26 EVCE: 5075.05 A.D. = 1.10 K = 45.45 50.0' VC PVI STA = 24+89.28 PVI ELEV = 5075.55 BVCS: 24+64.28 BVCE: 5075.05 EVCS: 25+14.28 EVCE: 5075.70 A.D. = 1.40 K = 35.71 100.0' VC PVI STA = 29+57.42 PVI ELEV = 5078.36 BCVS: 29+07.42 BVCE: 5078.06 ECVS: 30+07.42 EVCE: 5080.11 A.D. = 2.90 K = 34.48 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 2.20% 3.50% -0.90% 0.60% 5065 5070 5075 5080 5085 5090 5065 5070 5075 5080 5085 5090 23+50 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 32+50 5075.23 5074.91 5075.64 5076.24 5076.86 5077.45 5078.67 5081.91 5075.36 5075.11 5074.98 5074.86 5075.11 5075.31 5075.49 5075.79 5075.94 5076.09 5076.39 5076.55 5076.71 5077.01 5077.16 5077.31 5077.60 5077.80 5078.15 5079.34 5080.16 5081.04 5082.82 5083.91 -1.14% 0.50% 0.80% 0.80% 0.60% 0.62% 0.59% 3.30% 3.50% 3.90% 4.30% 4.50% 4.70% -0.80% -0.50% -1.29% PVI STA = 23+68.39 PVI ELEV = 5075.41 PVI STA = 25+00.25 PVI ELEV = 5074.91 PVI STA = 25+55.60 PVI ELEV = 5075.35 PVI STA = 25+65.61 PVI ELEV = 5075.43 PVI STA = 27+06.12 PVI ELEV = 5076.28 PVI STA = 28+16.35 PVI ELEV = 5076.96 PVI STA = 30+44.06 PVI ELEV = 5079.96 PVI STA = 31+17.70 PVI ELEV = 5082.53 PVI STA = 31+27.70 PVI ELEV = 5082.92 PVI STA = 31+37.70 PVI ELEV = 5083.35 PVI STA = 31+66.12 PVI ELEV = 5084.63 PVI STA = 31+71.53 PVI ELEV = 5084.89 PVI STA = 23+75.51 PVI ELEV = 5075.36 PVI STA = 24+82.44 PVI ELEV = 5074.82 PVI STA = 23+64.11 PVI ELEV = 5075.46 106.0' VC PVI STA = 29+83.09 PVI ELEV = 5077.94 BCVS: 29+30.09 BVCE: 5077.63 ECVS: 30+36.09 EVCE: 5079.69 A.D. = 2.71 K = 39.04 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 5065 5070 5075 5080 5085 5090 5065 5070 5075 5080 5085 5090 23+50 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 32+50 5075.47 5075.27 5075.87 5076.46 5077.05 5077.65 5079.96 5083.56 5075.73 5075.19 5075.02 5075.14 5075.42 5075.57 5075.72 5076.02 5076.17 5076.32 5076.61 5076.75 5076.90 5077.20 5077.35 5077.50 5077.94 5078.42 5079.09 5080.83 5081.71 5082.59 5084.54 -0.90% -1.20% 3.90% -1.20% -0.90% 0.50% 3.72% 3.50% 0.64% 0.60% 0.58% 0.60% 0.60% PVI STA = 24+48.73 PVI ELEV = 5075.01 PVI STA = 24+38.69 PVI ELEV = 5075.06 PVI STA = 24+21.52 PVI ELEV = 5075.22 PVI STA = 31+27.47 PVI ELEV = 5084.63 PVI STA = 23+96.95 PVI ELEV = 5075.51 PVI STA = 23+90.92 PVI ELEV = 5075.58 PVI STA = 24+52.54 PVI ELEV = 5075.03 PVI STA = 24+97.05 PVI ELEV = 5075.25 PVI STA = 29+99.99 PVI ELEV = 5079.96 PVI STA = 30+73.64 PVI ELEV = 5082.53 PVI STA = 28+89.12 PVI ELEV = 5077.58 PVI STA = 27+92.13 PVI ELEV = 5077.00 PVI STA = 25+27.11 PVI ELEV = 5075.43 PVI STA = 26+40.31 PVI ELEV = 5076.11 99.4' VC PVI STA = 29+45.92 PVI ELEV = 5077.94 BCVS: 28+96.23 BVCE: 5077.63 ECVS: 29+95.62 EVCE: 5079.79 A.D. = 3.09 K = 32.22 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND EXISTING RIGHT-OF-WAY SIGN LEGEND: PROPOSED STORM SEWER PROPOSED STREET LIGHT / / / / / / / / PROPOSED CURB & GUTTER EXISTING EDGE OF ASPHALT PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. SEE SHEETS INT1 - INT4 FOR INTERSECTION DETAILS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE ST STOP R1-1 D3 STREET NAME 6"x30' 30"x30' P P PROPOSED STOP SIGN WITH STREET NAME SIGNS PROPOSED SIGN LEGEND: PROPOSED CENTERLINE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER Sheet of 73 COUNTRY CLUB RESERVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION BID SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com KEYMAP DOUGLAS RD TURNBERRY RD CENTERLINE ROYAL TROON AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) R8 PLAN AND PROFILE ROYAL TROON AVENUE 49 ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LINE MATCH STA 23+50 LEFT FLOWLINE ROYAL TROON AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R7 STA 23+50 RIGHT FLOWLINE ROYAL TROON AVENUE SCALE : 1" = 40' (H) 1" = 5' (V) R6 R8 R7 Line Over Text Line Over Text 7/21/2020 EVCE: 5076.90 A.D. = 1.40 K = 35.71 75.0' VC PVI STA = 13+77.55 PVI ELEV = 5079.73 BCVS: 13+40.05 BVCE: 5080.67 ECVS: 14+15.05 EVCE: 5079.51 A.D. = 1.90 K = 39.47 PROPOSED GRADE EXISTING GROUND 5083.73 5083.53 5084.02 5084.40 5084.61 5084.75 5084.75 5084.55 5084.14 5083.55 5082.92 5082.30 5081.67 5081.05 5080.43 5079.95 5079.63 5079.45 5079.30 5079.15 5079.00 5078.85 5078.70 5078.55 5078.40 5078.25 5078.10 5077.95 5077.80 5077.65 5077.49 5077.19 5076.72 5076.47 PROPOSED GRADE EXISTING GROUND WINGED FOOT DR. SEE SHEET R2 ROYAL TROON AVE. SEE SHEET R8 30'  -  4.5' SIDEWALK CARNOUSTIE DR. 4.5' SIDEWALK 53' ROW WINGED FOOT DR. SEE SHEET R2 P P 9' UTILITY EASEMENT 9' UTILITY EASEMENT R20' R20' R20' R20' ROYAL TROON AVE. SEE SHEET R8 5' DRAINAGE AND GRADING EASEMENT (TYP.) 6' UTILITY EASEMENT (TYP.) LOT 19 LOT 18 LOT 16 LOT 13 LOT 14 LOT 17 LOT 15 LOT 13 LOT 17 LOT 15 LOT 19 LOT 21 LOT 18 LOT 16 LOT 20 LOT 14 LOT 1 LOT 7 LOT 8 LOT 4 LOT 3 LOT 2 LOT 5 LOT 4 LOT 6 BLOCK 10 BLOCK 10 BLOCK 9 31" DRIVE-OVER CURB AND GUTTER 31" DRIVE-OVER CURB AND GUTTER 5070 5075 5080 5085 5090 5095 5070 5075 5080 5085 5090 5095 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 PROPOSED GRADE EXISTING GROUND 5083.30 5083.69 5083.98 5084.20 5084.35 5084.29 5083.98 5083.43 5082.78 5082.16 5081.53 5080.90 5080.28 5079.73 5079.33 5079.10 5078.95 5078.80 5078.64 5078.49 5078.33 5078.18 5078.02 5077.87 5077.71 5077.56 5077.41 5077.26 5077.11 5076.93 5076.68 -0.60% -0.60% -0.60% -0.62% -2.75% -2.50% 0.66% 1.00% 1.00% 1.80% 1.40% -1.00% -1.40% PVI STA = 10+16.83 PVI ELEV = 5083.15 PVI STA = 10+35.00 PVI ELEV = 5083.48 PVI STA = 10+61.05 PVI ELEV = 5083.84 PVI STA = 10+70.54 PVI ELEV = 5083.94 PVI STA = 10+92.62 PVI ELEV = 5084.16 PVI STA = 12+09.89 PVI ELEV = 5083.16 PVI STA = 14+55.60 PVI ELEV = 5078.76 PVI STA = 16+68.35 PVI ELEV = 5077.45 PVI STA = 17+20.33 PVI ELEV = 5077.13 PVI STA = 17+43.15 PVI ELEV = 5077.00 PVI STA = 17+81.58 PVI ELEV = 5076.61 PVI STA = 17+98.60 PVI ELEV = 5076.38 86.4' VC HP ELEV = 5084.36 HP STA = 11+31.50 PVI STA = 11+57.92 PVI ELEV = 5084.59 BVCS: 11+14.74 BVCE: 5084.30 EVCS: 12+01.11 EVCE: 5083.40 A.D. = 3.42 K = 25.27 75.0' VC PVI STA = 13+63.61 PVI ELEV = 5079.31 BCVS: 13+26.11 BVCE: 5080.25 ECVS: 14+01.11 EVCE: 5079.09 A.D. = 1.90 K = 39.47 PROPOSED GRADE EXISTING GROUND 5070 5075 5080 5085 5090 5095 5070 5075 5080 5085 5090 5095 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 5083.59 5083.83 5084.03 5084.17 5084.31 5084.35 5084.22 5083.92 5083.45 5082.85 5082.23 5081.60 5080.98 5080.35 5079.78 5079.37 5079.12 5078.96 5078.81 5078.67 5078.52 5078.38 5078.23 5078.08 5077.94 5077.79 5077.65 5077.50 5077.35 5077.20 5077.02 5076.77 5076.49 -2.00% 0.55% 1.04% -1.00% -2.29% -2.50% 0.90% 0.55% -0.60% -0.58% -0.60% -0.80% PVI STA = 10+16.83 PVI ELEV = 5083.50 PVI STA = 10+34.97 PVI ELEV = 5083.69 PVI STA = 10+70.55 PVI ELEV = 5084.01 PVI STA = 10+97.04 PVI ELEV = 5084.16 PVI STA = 12+37.76 PVI ELEV = 5083.16 PVI STA = 14+83.47 PVI ELEV = 5078.76 PVI STA = 17+09.38 PVI ELEV = 5077.45 PVI STA = 17+61.36 PVI ELEV = 5077.13 PVI STA = 17+74.37 PVI ELEV = 5077.03 PVI STA = 18+21.74 PVI ELEV = 5076.56 PVI STA = 18+39.56 PVI ELEV = 5076.20 103.6' VC HP ELEV = 5084.36 HP STA = 11+43.65 PVI STA = 11+75.40 PVI ELEV = 5084.59 BVCS: 11+23.58 BVCE: 5084.30 EVCS: 12+27.21 EVCE: 5083.40 A.D. = 2.84 K = 36.44 75.0' VC PVI STA = 13+91.48 PVI ELEV = 5079.31 BCVS: 13+53.98 BVCE: 5080.25 ECVS: 14+28.98 EVCE: 5079.09 A.D. = 1.90 K = 39.47 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND Sheet of 73 COUNTRY CLUB RESERVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION BID SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com KEYMAP DOUGLAS RD TURNBERRY RD EXISTING RIGHT-OF-WAY SIGN LEGEND: PROPOSED STORM SEWER PROPOSED STREET LIGHT / / / / / / / / PROPOSED CURB & GUTTER EXISTING EDGE OF ASPHALT PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. SEE SHEETS INT1 - INT4 FOR INTERSECTION DETAILS. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE ST STOP R1-1 D3 STREET NAME 6"x30' 30"x30' P P PROPOSED STOP SIGN WITH STREET NAME SIGNS PROPOSED SIGN LEGEND: PROPOSED CENTERLINE PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING STORM SEWER CENTERLINE CARNOUSTIE DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) R5 PLAN AND PROFILE CARNOUSTIE DRIVE 46 NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R R5 LEFT FLOWLINE CARNOUSTIE DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE CARNOUSTIE DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) Line Over Text 7/21/2020