Loading...
HomeMy WebLinkAboutBROTHERS BBQ - FDP200021 - SUBMITTAL DOCUMENTS - ROUND 1 - PHOTOMETRIC PLANELECTRICAL SPECIFICATIONS GENERAL REQUIREMENTS DRAWINGS ARE DIAGRAMMATIC AND DO NOT INDICATE ALL FITTINGS, JUNCTION BOXES, ETC. REQUIRED. PROVIDE ALL REQUIRED EQUIPMENT, CONDUIT, FITTINGS, WIRING, BOXES, ETC. FOR A COMPLETE AND OPERATIONAL INSTALLATION. WORK AND EQUIPMENT SHALL COMPLY WITH STATE AND LOCALLY ADOPTED CODES AND STANDARDS, INCLUDING THE 2017 NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL CODES (I-CODES), AND LOCAL AMENDMENTS. ANYTHING DRAWN OR SPECIFIED SHALL NOT BE CONSTRUED TO CONFLICT WITH STATE AND LOCALLY ADOPTED CODES AND STANDARDS, INCLUDING THE NATIONAL ELECTRICAL CODE, WHICH GOVERNS THE INSTALLATION OF ANY ELECTRICAL WORK. ITEMS SHALL NOT BE INSTALLED IN CONFLICT WITH THE NEC. RESOLVE ANY AND ALL CONFLICTS PRIOR TO INSTALLATION. BECOME THOROUGHLY ACQUAINTED WITH THE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. EXAMINE ALL SERVICES, EQUIPMENT, AND EXISTING CONDITIONS, WHICH THIS WORK IS IN ANY WAY DEPENDENT UPON, AND BRING ANY DISCREPANCIES OR OMISSIONS FOUND IN THE DRAWINGS TO THE ELECTRICAL ENGINEER'S ATTENTION PRIOR TO SUBMITTING BID. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE. THE ARCHITECT AND ENGINEER SHALL HAVE THE RIGHT TO ADJUST THE LOCATION OF OUTLETS OR FIXTURES, WITHIN 10' OF THE SPECIFIED LOCATION, BEFORE THEY ARE INSTALLED AND WITHOUT ADDITIONAL COST. PROVIDE DRAWINGS TO LOCAL BUILDING AUTHORITY AND OBTAIN A PERMIT PRIOR TO STARTING ANY WORK. NOTIFY ELECTRICAL ENGINEER OF ANY CHANGES REQUESTED BY THE LOCAL BUILDING AUTHORITY IMMEDIATELY AND PRIOR TO STARTING WORK. VERIFY AND COMPLY WITH UTILITY COMPANY REQUIREMENTS. PROVIDE METERING, CONNECTION CABINETS, CT CABINETS, AND TRANSFORMER AND CONNECTION CABINET PADS PER LOCAL UTILITY COMPANY REQUIREMENTS. PROVIDE A REDLINED AS-BUILT SET OF ELECTRICAL DRAWINGS TO OWNER UPON COMPLETION OF WORK. ELECTRICAL WORK SHOWN LIGHT OR MARKED "E" IS EXISTING, SHOWN DARK IS NEW, AND SHOWN DASHED IS EXISTING TO BE REMOVED OR RELOCATED UNLESS OTHERWISE INDICATED. DASHING MAY ALSO INDICATE UNDER FLOOR OR UNDER GROUND CONDUIT. IF UNCLEAR, CONTACT ELECTRICAL ENGINEER FOR CLARIFICATION. EQUIPMENT, WIRING, AND DEVICES SHOWN ARE NEW UNLESS OTHERWISE NOTED. MAINTAIN CIRCUITING TO EXISTING EQUIPMENT AND DEVICES TO REMAIN. REFERENCE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. INSTALL EQUIPMENT AND DEVICES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. NOTIFY ELECTRICAL ENGINEER, PRIOR TO INSTALLING EQUIPMENT AND DEVICES, IF MANUFACTURER'S INSTALLATION INSTRUCTIONS CONFLICT WITH ELECTRICAL INFORMATION ON THE THESE DRAWINGS. ELECTRICALLY OPERATED EQUIPMENT SHOWN ON PLANS (ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL, CIVIL, EQUIPMENT SUPPLIER, SHOP DRAWINGS) AND NOT CIRCUITED ON THE ELECTRICAL PLANS, WILL REQUIRE ELECTRICAL SERVICE. CONTACT ELECTRICAL ENGINEER FOR CONNECTION REQUIREMENTS AND CLARIFICATION PRIOR TO BID. THE COST FOR THIS WORK SHALL BE INCLUDED IN THE BID. PROVIDE HANGERS AND SUPPORTS TO ADEQUATELY AND SECURELY SUPPORT ELECTRICAL SYSTEM COMPONENTS IN A NEAT AND WORKMANLIKE MANNER. MAINTAIN THE FIRE RATING OF THE ASSEMBLY (CEILING, WALL, OR FLOOR) IN WHICH EQUIPMENT, WIRING, AND DEVICES ARE TO BE INSTALLED. EQUIPMENT SHALL BE FULLY RATED FOR THE AMBIENT CONDITIONS (ELEVATION, TEMPERATURE, WIND LOAD, SOIL CONDITIONS, ETC) AT THE PROJECT LOCATION. KEEP PRODUCTS IN ORIGINAL MANUFACTURER'S PACKAGING AND PROTECT FROM DAMAGE UNTIL READY FOR INSTALLATION. PROVIDE PRODUCTS LISTED, CLASSIFIED, AND LABELED AS SUITABLE FOR THE PURPOSE INTENDED. UNLESS SPECIFICALLY INDICATED TO BE EXCLUDED, PROVIDE ALL REQUIRED CONDUIT, BOXES, WIRING, CONNECTORS, HARDWARE, SUPPORTS, TRIMS, ACCESSORIES, ETC. AS NECESSARY FOR COMPLETE AND OPERATIONAL SYSTEMS. SUBMITTALS AND SUBSTITUTIONS PROVIDE PRODUCT DATA SHEETS AND SHOP DRAWINGS FOR EQUIPMENT, FIXTURES, AND DEVICES M 400A3P 400FRN-R PANEL L1 #2 #2 #2 #6 WATER SERVICE BUILDING STEEL (IF AVAILABLE) GROUND ROD N G 2[(4-250kcmil AL, 1 #1 AL G)2 1/2"C] (400A) 2[(4-250kcmil AL)2 1/2"C] (400A) T UTILITY COMPANY PAD MOUNTED TRANSFORMER 208Y/120V, 3Ø, 4W SECONDARY 2[(4-250kcmil AL)2 1/2"C] (400A) LIGHTING FIXTURE SCHEDULE PREPARED BY KAZIN & ASSOCIATES DESCRIPTION OF LUMINAIRE BASIS OF DESIGN ID DESCRIPTION FINISH MOUNTING INFO MANUFACTURER CATALOG NUMBER LOAD (VA) VOLTAGE A 2' X 4' LAY-IN LED WITH A12 LENS & STEP DIMMER DRIVER WHITE RECESSED COLUMBIA LJT24-35VLG-FSA12EDU 59 120-277 B SEMI-RECESSED LED DOWNLIGHT WHITE 4" BOX PRESCOLITE LBSLEDA10L35K9WH 16.4 120 C CORD HUNG LED DOME PER ARCH CORD TMS LIGHTING CAL 1 12 100IN CRD 7W LED 120 D8 SURFACE MOUNTED 8' LED STRIP WHITE SURFACE COLUMBIA LCL8-35LW-EU 38 120-277 D4 SURFACE MOUNTED 4' LED STRIP WHITE SURFACE COLUMBIA LCL4-35LW-EU 19 120-277 F WALL BRACKET MOUNTED DOME WITH 17W 3000K LED LAMP PER ARCH WALL BRACKET TMS LIGHTING QS-2W O 17LED 120 17 120 G4 WALL MOUNTED FULL CUT-OFF 3000K LED AREA LIGHT WITH TYPE 4 DISTRIBUTION BLACK WALL +10' HUBBELL TRP1-12L-30-3K7-4-UNV-BL 30 120-277 G2 WALL MOUNTED FULL CUT-OFF 3000K LED AREA LIGHT WITH TYPE 2 DISTRIBUTION BLACK WALL +10' HUBBELL TRP1-12L-30-3K3-2-UNV-BL 30 120-277 NOTES: 1. FIXTURE SPECIFICATIONS REPRESENT THE ENGINEER'S UNDERSTANDING OF THE REQUIRED FIXTURES. FIXTURE SPECIFICATIONS SHALL BE REVIEWED AND APPROVED IN WRITING BY OWNER OR OWNER'S REPRESENTATIVE PRIOR TO ORDERING FIXTURES. NOTIFY ELECTRICAL ENGINEER OF ANY FIXTURE CHANGES PRIOR TO PURCHASING FIXTURES. 2. PROVIDED HANGERS, ADAPTERS, INSTALLATION KITS, PARTS AND PIECES TO INSTALL THE SPECIFIED FIXTURE IN THE LOCATIONS SHOWN ON THE PLAN. 3. UNLESS OTHERWISE INDICATED, PROVIDE COMPLETE LUMINAIRES INCLUDING LAMP(S) AND ALL SOCKETS, BALLASTS, REFLECTORS, LENSES, HOUSINGS AND OTHER COMPONENTS REQUIRED TO POSITION, ENERGIZE AND PROTECT THE LAMP AND DISTRIBUTE THE LIGHT. 4. UNLESS SPECIFICALLY INDICATED TO BE EXCLUDED, PROVIDE ALL REQUIRED CONDUIT, BOXES, WIRING, CONNECTORS, HARDWARE, SUPPORTS, TRIMS, ACCESSORIES, ETC. AS NECESSARY FOR A COMPLETE OPERATING SYSTEM. EXIT AND EMERGENCY LIGHTING FIXTURE SCHEDULE GAS METER & SERVICE RE: MECHANICAL DWGS 3 PHASE PAD MOUNT ELECTRICAL TRANSFORMER W/ BOLLARDS @ NE & SE CORNER ELECTRICAL METER & SERVICE UNDERGROUND ELECT. SERVICE 10'-0" ONSITE UTILITY EASEMENT FOR POWER AND LIGHT Sheet Number: E3 Description Date 2020/04/06 BROTHERS BBQ FORT COLLINS NATHAN HALL ARCHITECTURE, LLC nathanwhall@outlook.com 501 S Taft Hill Rd Fort Collins, CO 80521 Kazin & Associates, Inc. Village Square at Lone Tree 9364 Teddy Lane, Ste #101 Lone Tree, CO 80124 © 2020 Phone: 720-489-1609 Fax: 720-489-1611 Project #: 20097 Consulting Electrical Engineers Est. 1984 1 AS NOTED 2020/04/22 2 AS NOTED 2020/07/10 N I Z A K . M D I V A D R E E N I G N E L A N VESTIBULE 108 DINING ROOM 101 FOOD SERVICE AREA 102 STORAGE 103 FOOD COUNTER 104 KITCHEN 110 PREP AREA 105 STORAGE 112 MENS R.R. 107 WOMENS R.R. 109 MECH. /UTILITY 106 FRONT DINING PATIO 114 60" PASS SHELF DISHWASHING SODA DISPENSER POS TERMINAL WALK-IN COOLER 111 SMOKER PREP SINK SMOKER Gas Fryer Charbroiler, Gas, Countertop Gas Countertop Griddle DINING PATIO 113 30"X42" DINING TABLE 30"X42" DINING TABLE 30"X42" DINING TABLE Water Heater 30"X42" DINING TABLE 30"X42" DINING DINING PATIO 113 VESTIBULE 108 DINING ROOM 101 FOOD SERVICE AREA 102 STORAGE 103 FOOD COUNTER 104 KITCHEN 110 PREP AREA 105 STORAGE 112 MENS R.R. 107 WOMENS R.R. 109 MECH. /UTILITY 106 FRONT DINING PATIO 114 60" PASS SHELF DISHWASHING SODA DISPENSER POS TERMINAL WALK-IN COOLER 111 SMOKER PREP SINK SMOKER Gas Fryer Charbroiler, Gas, Countertop Gas Countertop Griddle DINING PATIO 113 30"X42" DINING TABLE 30"X42" DINING TABLE 30"X42" DINING TABLE Water Heater 30"X42" DINING TABLE G4 G4 G4 G4 G4 G4 G4 G4 G4 G2 G4 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.6 0.7 0.6 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.5 0.4 0.3 0.3 0.2 0.3 0.3 0.3 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.5 0.9 1.1 1.1 0.9 0.8 0.8 1.0 1.1 1.2 1.0 0.8 0.6 0.5 0.5 0.4 0.5 0.5 0.6 0.6 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 1.1 1.8 2.0 1.7 1.8 1.7 2.0 2.2 2.1 1.6 1.3 1.2 1.0 0.9 0.7 1.0 1.1 1.2 1.0 0.9 0.6 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 1.3 2.3 2.8 3.0 2.9 3.0 3.7 3.8 3.3 2.9 2.7 2.4 2.2 2.0 1.7 2.2 2.1 2.0 1.9 1.3 0.8 0.5 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 1.1 2.9 3.7 2.8 2.3 2.5 4.8 5.4 5.8 5.7 5.5 5.3 5.1 4.7 4.0 4.4 3.8 3.5 2.5 1.6 1.0 0.6 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.7 2.6 3.9 1.7 2.9 9.9 3.6 6.6 8.1 8.4 8.4 8.2 7.8 7.3 6.3 6.1 5.6 4.9 3.2 2.0 1.2 0.7 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.5 2.3 2.8 8.9 4.9 5.3 3.9 2.2 1.3 0.7 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.7 2.8 3.7 5.1 5.0 6.6 4.5 2.4 1.4 0.8 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.9 1.9 4.3 4.8 6.2 7.5 5.1 2.9 1.6 0.9 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.8 2.1 4.4 13.2 6.4 7.6 5.5 3.1 1.8 1.0 0.6 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.6 3.1 3.2 4.1 8.0 8.4 5.8 3.5 1.9 1.1 0.6 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.5 2.0 2.7 9.6 6.5 8.0 5.9 3.4 1.9 1.1 0.6 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.7 2.5 3.7 1.9 2.0 7.2 5.5 4.8 3.5 2.3 6.1 6.3 8.3 6.0 3.4 2.0 1.1 0.6 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 1.0 2.5 3.0 2.5 4.0 2.8 4.0 5.9 4.1 3.0 5.1 6.8 8.3 5.8 3.4 1.9 1.1 0.6 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 1.1 1.9 2.3 2.5 3.2 3.4 4.7 5.2 5.3 10.0 13.2 6.5 7.5 5.6 3.1 1.7 1.0 0.6 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 0.9 1.4 1.8 1.8 2.0 2.3 3.5 4.8 3.6 2.6 3.6 7.2 7.7 5.0 2.9 1.6 0.9 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.7 0.9 1.1 1.1 1.3 1.8 2.6 3.4 2.8 2.1 9.2 5.1 6.2 4.4 2.4 1.4 0.8 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.5 0.6 0.7 0.7 1.0 1.6 2.3 2.9 3.2 1.2 6.7 4.8 5.7 4.1 2.2 1.3 0.7 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.4 0.5 0.6 0.9 1.4 2.0 3.0 3.2 5.2 6.9 4.0 8.5 4.6 5.5 8.3 5.7 6.2 3.9 2.3 1.3 0.8 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.4 0.5 0.7 1.2 1.8 3.0 4.9 4.1 5.4 8.0 6.1 7.4 5.8 5.4 6.9 5.2 3.6 2.2 1.2 0.7 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.7 1.0 1.8 2.7 3.7 4.5 5.5 6.2 6.5 6.3 5.6 5.3 4.8 4.1 3.1 2.0 1.2 0.7 0.4 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.5 0.9 1.5 2.0 2.4 2.8 3.0 3.7 3.7 3.7 3.2 3.1 2.9 2.7 2.2 1.5 0.9 0.6 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.7 1.0 1.2 1.4 1.6 1.7 2.0 2.0 2.0 1.8 1.7 1.7 1.5 1.4 1.0 0.7 0.4 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.1 1.1 1.0 1.0 1.0 0.9 0.8 0.6 0.5 0.3 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 F F F F F G4 Sheet Number: E6 Description Date 2020/04/06 BROTHERS BBQ FORT COLLINS NATHAN HALL ARCHITECTURE, LLC nathanwhall@outlook.com 501 S Taft Hill Rd Fort Collins, CO 80521 Kazin & Associates, Inc. Village Square at Lone Tree 9364 Teddy Lane, Ste #101 Lone Tree, CO 80124 Sheet Number: E7 Description Date 2020/04/06 BROTHERS BBQ FORT COLLINS NATHAN HALL ARCHITECTURE, LLC nathanwhall@outlook.com 501 S Taft Hill Rd Fort Collins, CO 80521 Kazin & Associates, Inc. Village Square at Lone Tree 9364 Teddy Lane, Ste #101 Lone Tree, CO 80124 © 2020 Phone: 720-489-1609 Fax: 720-489-1611 Project #: 20097 Consulting Electrical Engineers Est. 1984 1 AS NOTED 2020/04/22 2 AS NOTED 2020/07/10 N I Z A K . M D I V A D R E E N I G N E L A N O I S S E F O R P 20747 O D A R O L O C L I C E N S E D NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY DAVID KAZIN. LIMITED TO ELECTRICAL. 7-10-20 © 2020 Phone: 720-489-1609 Fax: 720-489-1611 Project #: 20097 Consulting Electrical Engineers Est. 1984 1 AS NOTED 2020/04/22 2 AS NOTED 2020/07/10 N I Z A K . M D I V A D R E E N I G N E L A N O I S S E F O R P 20747 O D A R O L O C L I C E N S E D NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY DAVID KAZIN. LIMITED TO ELECTRICAL. 7-10-20 NORTH 1 SITE LIGHTING PHOTOMETRIC PLAN SCALE: 1/8" = 1'-0" 2 30"X42" DINING TABLE 30"X24" DINING TABLE 30"X42" DINING TABLE 30"X24" DINING TABLE 30"X24" DINING TABLE 30"X42" DINING TABLE 30"X24" DINING TABLE BEVERAGE COOLER/ MERCH- ANIDISER 24 25 3 3 Serving Counter, Hot Food, Electric 6 FULL HT. ALTO- SHAAM 4 Toaster 10 2 1 HOOD ABOVE HOOD ABOVE 14 D Cold Food / Sandwich Prep FULL HT. ALTO- SHAAM 4 28"x18" 2436 Bib Rack x5 32 5 2.1 1.1 33 45 POS TERMINAL 45 EXIT EXIT EXIT 15 43 44 TEA BREWER 1830 x4 FULL HT. ALTO- SHAAM 4 FULL HT. ALTO- SHAAM 4 OS OS OS 3 3 J A A A A A A A A A A B B B B B B B B B B B B B B B B B B B B B B B B C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C B B B a a a a a a a a a a a a b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b c c c d d d d d d d d d d D D D 3 3 3 3 OS D8 D8 D8 EF-4 EF-3 L1-2 L1-4 L1-6 L1-8 S T FOR LIGHTING CONTROL RELAY J J ON ROOF FOR SIGNS F F F F F G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G2 G4 B B B B B B D4 L1-8 L1-10 D4 Sheet Number: E5 Description Date 2020/04/06 BROTHERS BBQ FORT COLLINS NATHAN HALL ARCHITECTURE, LLC nathanwhall@outlook.com 501 S Taft Hill Rd Fort Collins, CO 80521 Kazin & Associates, Inc. Village Square at Lone Tree 9364 Teddy Lane, Ste #101 Lone Tree, CO 80124 © 2020 Phone: 720-489-1609 Fax: 720-489-1611 Project #: 20097 Consulting Electrical Engineers Est. 1984 1 AS NOTED 2020/04/22 2 AS NOTED 2020/07/10 N I Z A K . M D I V A D R E E N I G N E L A N O I S S E F O R P 20747 O D A R O L O C L I C E N S E D NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY DAVID KAZIN. LIMITED TO ELECTRICAL. 7-10-20 NORTH 1 LIGHTING PLAN SCALE: 1/4" = 1'-0" TABLE 30"X24" DINING TABLE 30"X42" DINING TABLE 30"X24" DINING TABLE 30"X24" DINING TABLE 30"X42" DINING TABLE 30"X24" DINING TABLE BEVERAGE COOLER/ MERCH- ANIDISER 24 25 3 3 Serving Counter, Hot Food, Electric 6 FULL HT. ALTO- SHAAM 4 Toaster 10 2 1 HOOD ABOVE HOOD ABOVE 14 D Cold Food / Sandwich Prep FULL HT. ALTO- SHAAM 4 28"x18" 2436 Bib Rack x5 32 5 2.1 1.1 33 45 POS TERMINAL 45 EXIT EXIT EXIT 15 43 44 TEA BREWER 1830 x4 FULL HT. ALTO- SHAAM 4 FULL HT. ALTO- SHAAM 4 ABOVE WINDOW ABOVE WINDOW ABOVE WINDOW ABOVE WINDOW ABOVE WINDOW ABOVE WINDOW ABOVE WINDOW L1-33 L1-31 L1-29 L1-35 L1-37 L1-27 L1-25 L1-5,7 L1-17,19 L1-49 L1-9,11 L1-13,15 L1 L1-1,3 L1-21 L1-23 L1-47 L1-52 EF-1 EF-2 J L1-45 L1-41,43 L1-62,64,66 L1-56,58,60 RTU-1 MAU-1 WP WP L1-68,70,72 L1-80,82,84 RTU-2 WP L1-74,76,78 WP GFI WP GFI L1-53,55 L1-54 L1-11,59 M CT Sheet Number: E4 Description Date 2020/04/06 BROTHERS BBQ FORT COLLINS NATHAN HALL ARCHITECTURE, LLC nathanwhall@outlook.com 501 S Taft Hill Rd Fort Collins, CO 80521 Kazin & Associates, Inc. Village Square at Lone Tree 9364 Teddy Lane, Ste #101 Lone Tree, CO 80124 © 2020 Phone: 720-489-1609 Fax: 720-489-1611 Project #: 20097 Consulting Electrical Engineers Est. 1984 1 AS NOTED 2020/04/22 2 AS NOTED 2020/07/10 N I Z A K . M D I V A D R E E N I G N E L A N O I S S E F O R P 20747 O D A R O L O C L I C E N S E D NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY DAVID KAZIN. LIMITED TO ELECTRICAL. 7-10-20 NORTH 1 POWER PLAN SCALE: 1/4" = 1'-0" 1 1 1 1 1 1 2 O I S S E F O R P 20747 O D A R O L O C L I C E N S E D NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY DAVID KAZIN. LIMITED TO ELECTRICAL. 7-10-20 NORTH 1 ELECTRICAL SITE PLAN SCALE: 1/8" = 1'-0" 2 DESCRIPTION OF LUMINAIRE LUMINAIRE SPECIFICATION SYMBOL DESCRIPTION FINISH MOUNTING INFO MANUFACTURER CATALOG NUMBER LAMP(S) VOLTAGE EXIT LIGHT (UNIVERSAL) WITH 90-MINUTE BATTERY WHITE SEE PLAN DUAL-LITE OR EQUAL EVE-U-G-W-E-I LED 120/277 INPUT EXIT/EM LIGHT (UNIVERSAL) WITH 90-MINUTE BATTERY WHITE SEE PLAN DUAL-LITE OR EQUAL EVC-U-G-W-D4-I LED + (2) 1W LED HEADS 120/277 INPUT EMERGENCY LIGHT WITH 90-MINUTE BATTERY WHITE SEE PLAN DUAL-LITE OR EQUAL EV-4-D-I-02L (2) 2W LED LAMPS 120/277 INPUT EXTERIOR EMERGENCY EGRESS LIGHT WITH 90-MINUTE BATTERY MATCH SURROUNDING SURFACE SEE PLAN DUAL-LITE OR EQUAL PG-(WHITE, DARK BRONZE, PLATINUM SILVER, BLACK)-HTR (2) LED BOARDS + HEATER (16W) 120/277 INPUT EXTERIOR REMOTE EMERGENCY EGRESS HEADS (POWERED BY INTERIOR EXIT/EM FIXTURE) MATCH SURROUNDING SURFACE SEE PLAN DUAL-LITE OR EQUAL EVO-D-(BLACK,WHITE) (FEED FROM EXIT/EM COMBO) (2) 3W LED EXIT/EM BATTERY EMWP WATTSTOPPER RT-200 TIME SWITCH MANUAL ON, TIME CLOCK OFF AT CLOSING TIME, SWEEP OFF EVERY TWO HOURS UNTIL 30 MINUTES BEFORE OPENING TIME. COORDINATE TIMES WITH OWNER. C L1-4 L1-2 120V L N 20A, ELECTRICALLY HELD LIGHTING RELAY IN NEMA 1 ENCLOSURE INTERIOR LIGHTING INTERIOR LIGHTING Sheet Number: E2 Description Date 2020/04/06 BROTHERS BBQ FORT COLLINS NATHAN HALL ARCHITECTURE, LLC nathanwhall@outlook.com 501 S Taft Hill Rd Fort Collins, CO 80521 Kazin & Associates, Inc. Village Square at Lone Tree 9364 Teddy Lane, Ste #101 Lone Tree, CO 80124 © 2020 Phone: 720-489-1609 Fax: 720-489-1611 Project #: 20097 Consulting Electrical Engineers Est. 1984 1 AS NOTED 2020/04/22 2 AS NOTED 2020/07/10 N I Z A K . M D I V A D R E E N I G N E L A N O I S S E F O R P 20747 O D A R O L O C L I C E N S E D NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY DAVID KAZIN. LIMITED TO ELECTRICAL. 7-10-20 1 ONE-LINE DIAGRAM NOT TO SCALE 2 LIGHTING CONTROL SCHEMATIC DIAGRAM NOT TO SCALE 1 1 1 1 1 1 2 TO ELECTRICAL ENGINEER PRIOR TO PURCHASING. REVIEW, STAMP AND INITIAL ALL ELECTRICAL SUBMITTALS AND SHOP DRAWINGS CERTIFYING THAT THE SUBMITTALS HAVE BEEN REVIEWED PRIOR TO SUBMITTING TO ELECTRICAL ENGINEER FOR REVIEW. EQUIPMENT AND FIXTURES SPECIFIED REPRESENT REQUIRED QUALITY AND PERFORMANCE. PROVIDE PRODUCT DATA SHEETS AND SHOP DRAWING OF PROPOSED SUBSTITUTIONS TO SPECIFIED EQUIPMENT TO ELECTRICAL ENGINEER FOR REVIEW. ELECTRICAL ENGINEER SHALL DETERMINE THE ACCEPTABILITY OF SUBSTITUTIONS TO SPECIFIED EQUIPMENT. REVIEW, STAMP AND INITIALED ALL ELECTRICAL SUBMITTALS AND SHOP DRAWINGS CERTIFYING THAT SUBMITTALS HAVE BEEN REVIEWED PRIOR TO SUBMITTING TO ELECTRICAL ENGINEER FOR REVIEW. SUBMITTALS AND SHOP DRAWINGS ARE TO INCLUDE THE FOLLOWING: KEY TO PLAN DESIGNATIONS, MANUFACTURER, MODEL NUMBER, DATA SHEETS, QUANTITIES, COLORS, LABELS, DIMENSIONS, INSTALLATION INSTRUCTIONS, AND ANY ADDITIONAL INFORMATION REQUIRED TO DETERMINE IF THE PRODUCT MEETS THE DESIGN INTENT. CONSTRUCTION PHASE REVIEW REQUIREMENTS INSTALL POWER, LIGHTING, COMMUNICATIONS AND SPECIAL SYSTEM (FIRE ALARM, SECURITY, BUILDING AUTOMATION, ETC) BOXES PRIOR TO RUNNING CABLE OR CONDUIT TO BOXES. ARRANGE FOR OWNER, ARCHITECT, AND ENGINEER TO REVIEW BOX LOCATIONS PRIOR TO RUNNING CABLE OR CONDUIT TO BOXES. ADJUST BOXES AS DIRECTED BY OWNER, ARCHITECT, AND ENGINEER. REQUESTS FOR MODIFICATIONS TO THE CONTRACT (CHANGE ORDERS) REQUESTS BY CONTRACTOR FOR ADDITION OR REDUCTION TO THE CONTRACT AMOUNT SHALL BE ACCOMPANIED BY THE FOLLOWING FOR EVALUATION BY THE OWNER AND ENGINEER: 1. ORIGIN AND DATE OF CLAIM 2. QUANTITIES OF PRODUCTS, LABOR, AND EQUIPMENT 3. DOLLAR AMOUNT OF TAXES, OVERHEAD, AND PROFIT 4. JUSTIFICATION FOR ANY CHANGE IN CONTRACT TIME 5. CREDIT AMOUNT FOR DELETIONS (WITH DOCUMENTATION) 6. DATES AND TIMES OF WORK PERFORMED, AND BY WHOM 7. TIME RECORDS AND WAGE RATES PAID 8. INVOICES AND RECEIPTS FOR PRODUCTS AND EQUIPMENT SUBMIT ALL DOCUMENTATION TO ENGINEER AND OWNER, AND OBTAIN WRITTEN APPROVAL PRIOR TO STARTING ANY WORK THAT AFFECTS THE CONTRACT AMOUNT OR COMPLETION DATE. EXISTING CONDITIONS THESE DRAWINGS CONTAIN INFORMATION REGARDING EXISTING CONDITIONS. THIS INFORMATION WAS COMPILED FROM EXISTING DRAWINGS, CASUAL FIELD OBSERVATIONS OR INFORMATION PROVIDED BY OTHERS. IN SOME CASES, ASSUMPTIONS WERE MADE WHEN FIELD OBSERVATIONS OR EXISTING DRAWINGS DID NOT PROVIDE NECESSARY INFORMATION (I.E. LOCKED DISCONNECTS, NO WIRE SIZE INDICATED, NAMEPLATE DATA MISSING, INACCURATE AS-BUILT DRAWINGS, ETC.). EXISTING CONDITIONS SHALL BE VERIFIED AND ALLOWED FOR PRIOR TO BID AND CONSTRUCTION. NOTIFY THE ELECTRICAL ENGINEER OF ANY DISCREPANCIES WITH THESE DRAWINGS IMMEDIATELY AND PRIOR TO COMMENCING ANY FURTHER WORK. COORDINATION THE ELECTRICAL DRAWINGS ARE ONLY ONE PART OF A COMPLETE SET OF CONSTRUCTION DOCUMENTS. EXAMINE THE ARCHITECTURAL, MECHANICAL, PLUMBING, AND CIVIL DRAWINGS PRIOR TO SUBMITTING BID AND STARTING WORK TO DETERMINE THE FULL EXTENT OF ELECTRICAL WORK REQUIRED. COORDINATE WORK WITH OTHER TRADES PRIOR TO ROUGH-IN. COORDINATION SHALL INCLUDE REVIEWING THE ARCHITECTURAL, MECHANICAL, PLUMBING, ETC. DRAWINGS AND SHOP DRAWINGS PRIOR TO BID AND CONSTRUCTION. OBTAIN AND REVIEW SHOP DRAWINGS, PRODUCT DATA, MANUFACTURER'S WIRING DIAGRAMS AND MANUFACTURER'S INSTRUCTIONS FOR EQUIPMENT PROVIDED BY OTHERS. THE FINAL LOCATION OF EQUIPMENT SHALL BE COORDINATED IN THE FIELD, PRIOR TO ROUGH-IN, TO MEET APPLICABLE LOCATION, HEIGHT AND CLEARANCE REQUIREMENTS. DEMOLITION DISCONNECT WIRING TO EQUIPMENT, DEVICES, AND FIXTURES TO BE REMOVED. REMOVE EQUIPMENT, WIRING, DEVICES AND CONDUIT NOT BEING USED. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS TO BE REMOVED. FIELD VERIFY EXISTING CONDITIONS TO DETERMINE EXTENT OF DEMOLITION WORK. REFERENCE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL PLANS FOR ADDITIONAL INFORMATION. DEMOLITION DRAWINGS ARE BASED ON CASUAL FIELD OBSERVATION AND EXISTING RECORD DOCUMENTS. DEMO PLANS ARE PROVIDED FOR REFERENCE ONLY. MAINTAIN THE ELECTRICAL SERVICE TO EXISTING EQUIPMENT AND DEVICES TO REMAIN. EXTEND EXISTING INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS. PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION. MAINTAINING EXISTING SERVICES MAINTAIN THE ELECTRICAL SERVICE TO EXISTING TENANTS AND AREAS. ANY SERVICE DISCONTINUITY SHALL BE COORDINATED AND APPROVED BY OWNER AND TENANTS PRIOR TO OUTAGE. IF REQUIRED, PROVIDE TEMPORARY POWER DURING OUTAGE. WIRING AND CONDUIT NEW WIRING SHALL BE THHN/THWN-2, 90°C INSULATED COPPER UNLESS OTHERWISE NOTED. ALUMINUM CONDUCTORS SHALL BE XHHW-2, INSULATED COMPACT STRAND. THE CONDUCTORS FOR 15A AND 20A BRANCH CIRCUITS SHALL BE #12 THHN/THWN-2, 90°C INSULATED COPPER. BRANCH-CIRCUIT CONDUCTORS GREATER THAN 20A SHALL BE AS INDICATED ON PLANS OR REQUIRED PER CODE. INCREASE CONDUCTOR SIZES AS REQUIRED TO LIMIT FEEDER VOLTAGE DROP TO 3%, BRANCH-CIRCUIT VOLTAGE DROP TO 3%, AND TOTAL VOLTAGE DROP (FEEDER + BRANCH-CIRCUIT) TO 5%. THE MAXIMUM NUMBER OF CONDUCTORS IN A CONDUIT FOR A 3Ø SYSTEM SHALL BE THREE (AØ, BØ, CØ), NOT INCLUDING NEUTRAL AND EQUIPMENT GROUNDING CONDUCTORS, UNLESS OTHERWISE INDICATED. CONDUIT SIZE SHALL BE BASED UPON NEC CHAPTER 9 AND ANNEX C. MORE THAN 3 CURRENT-CARRYING CONDUCTORS MAY BE INSTALLED IN A RACEWAY IF THE APPROPRIATE AMPACITY-DERATING FACTORS ARE APPLIED. THE MAXIMUM NUMBER OF CONDUCTORS IN A CONDUIT FOR A 1Ø SYSTEM SHALL BE TWO (AØ, BØ), NOT INCLUDING NEUTRAL AND EQUIPMENT GROUNDING CONDUCTORS UNLESS OTHERWISE INDICATED. CONDUIT SIZE SHALL BE BASED UPON NEC CHAPTER 9 AND ANNEX C. MORE THAN 3 CURRENT-CARRYING CONDUCTORS MAY BE INSTALLED IN A RACEWAY IF THE APPROPRIATE AMPACITY-DERATING FACTORS ARE APPLIED. PROVIDE A DEDICATED NEUTRAL FOR EACH LINE-TO-NEUTRAL CIRCUIT UNLESS A MULTI-POLE BREAKER, WHICH DISCONNECTS ALL PHASE CONDUCTORS THAT SHARE A NEUTRAL, IS PROVIDED (LISTED BREAKER-TIES ARE PERMITTED). PROVIDE AN INSULATED EQUIPMENT GROUNDING CONDUCTOR WITH ALL FEEDERS AND BRANCH-CIRCUIT WIRING. INCREASE CONDUIT SIZE AS REQUIRED TO ACCOMMODATE EQUIPMENT GROUNDING CONDUCTOR. PROVIDE ALL CONDUIT, FITTINGS, SUPPORTS, AND ACCESSORIES REQUIRED FOR A COMPLETE RACEWAY SYSTEM. CONDUIT SHALL BE CONCEALED IN WALLS, FLOOR OR CEILING IN FINISHED AREAS UNLESS OTHERWISE INDICATED. IN FINISHED AREAS, WHERE CONDUIT AND CABLE CAN NOT BE CONCEALED IN WALLS OR CEILINGS (I.E. EXISTING MASONRY CONSTRUCTION), PROVIDE WIREMOLD OR EQUAL SURFACE MOUNTED RACEWAY AS APPROVED BY ARCHITECT OR ENGINEER. UNLESS OTHERWISE INDICATED AND WHERE NOT OTHERWISE RESTRICTED, USE THE CONDUIT TYPES INDICATED BELOW FOR THE SPECIFIED APPLICATIONS. WHERE MORE THAN ONE LISTED APPLICATION APPLIES, COMPLY WITH THE MOST RESTRICTIVE REQUIREMENTS. WHERE CONDUIT TYPE FOR A PARTICULAR APPLICATION IS NOT SPECIFIED, USE GALVANIZED STEEL RIGID METAL CONDUIT. DO NOT USE CONDUIT AND ASSOCIATED FITTINGS FOR APPLICATIONS OTHER THAN AS PERMITTED BY NFPA 70 AND PRODUCT LISTING. REFERENCE THE NEC FOR ADDITIONAL APPLICATION REQUIREMENTS. APPLICATION TYPE OF CONDUIT IN CONCRETE OR MASONRY EMT, IMC, GRC, PVC OUTDOORS (ABOVE GRADE) EMT, IMC, GRC BRANCH CIRCUITS (EXPOSED) EMT, IMC, GRC INTERIOR BRANCH CIRCUITS (CONCEALED BEHIND DRYWALL) MC, EMT, IMC INTERIOR BRANCH CIRCUITS (ABOVE DROPPED CEILINGS) EMT, IMC SUPPLY TO DISTRIBUTION PANELS EMT, IMC, GRC, PVC UNDERGROUND PVC, IMC, GRC OVERHEAD SERVICE MAST GRC (2" MIN) CONNECTIONS TO LUMINAIRES ABOVE ACCESSIBLE CEILINGS: USE FLEXIBLE METAL CONDUIT. MAXIMUM LENGTH TO BE 6' UNLESS OTHERWISE INDICATED. WHERE MC CABLE IS PERMITTED TO BE USED, A 6' LENGTH IS PERMITTED TO BE EXPOSED ABOVE A DROPPED CEILING TO CONNECT THE ABOVE CEILING JUNCTION BOX TO THE DEVICES BEHIND DRYWALL. FINAL CONNECTIONS TO VIBRATING EQUIPMENT (MOTORS, TRANSFORMERS, ETC) SHALL BE MADE WITH FLEXIBLE METAL CONDUIT IN DRY LOCATIONS AND LIQUIDTIGHT FLEXIBLE METAL CONDUIT IN DAMP, WET, OR CORROSIVE LOCATIONS. MAXIMUM LENGTH TO BE 6' UNLESS OTHERWISE INDICATED. INSTALL RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS A MINIMUM OF 1" ABOVE ROOF SURFACE. PROVIDE PVC COATED GRC FOR ELBOWS IN PVC CONDUIT RUNS. ALL CONDUITS AND CABLES PASSING THROUGH RATED WALLS, FLOORS OR CEILINGS SHALL BE FIRE STOPPED WITH APPROVED FIRE BARRIER CAULK. INSTALL CAULK PER MANUFACTURE'S INSTRUCTIONS AND MAINTAIN THE RATING OF THE WALL, FLOOR, OR CEILING BEING PENETRATED. SERVICE CONDUCTORS: ROUTE OUTSIDE OF BUILDING OR STRUCTURE OTHER THAN AT THE POINT OF ENTRANCE TO CONNECT TO THE SERVICE DISCONNECTING MEANS. DEVICES DEVICE AND FACEPLATE COLOR SHALL BE AS SPECIFIED BY THE ARCHITECT OR TO MATCH EXISTING. COORDINATE FACEPLATE AND DEVICE COLORS WITH ARCHITECT, INTERIOR DESIGNER AND OWNER PRIOR TO PURCHASING AND INSTALLING DEVICES AND FACEPLATES. PROVIDE COMMERCIAL SPECIFICATION GRADE SWITCHES AND RECEPTACLES. PROVIDE DEVICES AS INDICATED BELOW: DEVICE MANUFACTURER MODEL NUMBER WALL OCCUPANCY SENSOR WATT STOPPER OR EQUAL DSW-301 3-WAY WALL OCC SENSOR WATT STOPPER OR EQUAL DSW-301 2-POLE WALL OCC SENSOR WATT STOPPER OR EQUAL DSW-302 WALL OCC WITH 0-10V DIMMING WATT STOPPER OR EQUAL DSW-311 3-WAY WALL OCC WITH 0-10V DIM WATT STOPPER OR EQUAL DSW-311 CEILING OCCUPANCY SENSOR WATT STOPPER OR EQUAL LMDC-100 CORNER OCCUPANCY SENSOR WATT STOPPER OR EQUAL LMDX-100 OCCUPANCY SENSOR CONTROL FUNCTION PER IECC (UNLESS OTHERWISE NOTED): PUBLIC CORRIDORS, STAIRWAYS, RESTROOMS: MANUAL ON, AUTO OFF WAREHOUSES: AUTO ON, AUTO OFF ALL OTHER LOCATIONS: MANUAL ON, AUTO OFF OCCUPANCY SENSOR LOCATION ADJUSTMENTS: LOCATIONS INDICATED ON PLANS ARE DIAGRAMMATIC AND ONLY INTENDED TO INDICATE WHICH ROOMS OR AREAS REQUIRE DEVICES. PROVIDE QUANTITY AND LOCATIONS AS REQUIRED FOR COMPLETE COVERAGE OF RESPECTIVE ROOM OR AREA BASED ON MANUFACTURER'S RECOMMENDATIONS FOR INSTALLED DEVICES. PHOTOCELL/PHOTOSENSOR LOCATION ADJUSTMENTS: LOCATIONS INDICATED ARE DIAGRAMMATIC AND ONLY INTENDED TO INDICATE WHICH ROOMS OR AREAS REQUIRE DEVICES. PROVIDE QUANTITY AND LOCATIONS AS REQUIRED FOR PROPER CONTROL OF RESPECTIVE ROOM OR AREA BASED ON MANUFACTURER'S RECOMMENDATIONS FOR INSTALLED DEVICES. DEMONSTRATE PROPER OPERATION OF LIGHTING CONTROL DEVICES TO OWNER, AND CORRECT DEFICIENCIES OR MAKE ADJUSTMENTS AS DIRECTED. GFCI PROTECTION FOR PERSONNEL PROTECTION: PROVIDE GFCI RECEPTACLE, FACELESS GFCI DEVICE FEEDING STANDARD RECEPTACLE, OR GFCI CIRCUIT-BREAKER. THE GROUND-FAULT CIRCUIT-INTERRUPTER SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION. NON-DWELLING UNIT GFCI PROTECTION: PROVIDE GFCI PROTECTION FOR 1Ø RECEPTACLES RATED 120V, 208V AND 240V, 50A OR LESS AND 3Ø RECEPTACLES RATED 208V AND 240V, 100A OR LESS FOR THE FOLLOWING: BATHROOMS, KITCHENS, ROOFTOPS, OUTDOORS, SINKS (WITHIN 6' OF TOP INSIDE EDGE OF SINK BOWL), ELECTRIC WATER COOLERS, INDOOR WET LOCATIONS, LOCKER ROOMS, CRAWL SPACES, UNFINISHED BASEMENTS, GARAGES, SERVICE BAYS, VEHICLE EXHIBITION HALLS AND SHOWROOMS, AND LOCATIONS INDICATED ON POWER PLAN OR REQUIRED PER THE NEC. GFCI PROTECTION: PROVIDE GFCI PROTECTION FOR 1Ø AND 3Ø APPLIANCES RATED 120V, 208V AND 240V, 60A OR LESS FOR THE FOLLOWING: PUBLIC USE AUTOMOTIVE VACUUM MACHINES, DRINKING WATER COOLERS, CORD-AND-PLUG HIGH PRESSURE SPRAY WASHING MACHINES, PUBLIC USE TIRE INFLATION MACHINES, VENDING MACHINES, AND LOCATIONS INDICATED ON POWER PLAN OR REQUIRED PER THE NEC. PROVIDE WEATHER-RESISTANT RECEPTACLES FOR RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS. PROVIDE HUBBELL RECEPTACLES WITH THE APPROPRIATE NEMA CONFIGURATION FOR RECEPTACLES SHOWN ON THE ELECTRICAL PLAN. PROVIDE 6' CORD AND PLUG FOR SPECIAL-PURPOSE RECEPTACLES IF EQUIPMENT TO BE INSTALLED IS NOT SUPPLIED WITH A CORD AND PLUG. PROVIDE FLOOR-MOUNTED DEVICE COVERS MOUNTED FLUSH WITH THE FINISHED FLOOR SURFACE. PROVIDE WIRING DEVICES AS MANUFACTURED BY HUBBELL, PASS AND SEYMOUR, LEVITION, WATT-STOPPER, LUTRON OR EQUAL. COORDINATE MOUNTING HEIGHTS OF SWITCHES, RECEPTACLES, PHONE OUTLETS, DATA OUTLETS, TV OUTLETS, AND LIGHT FIXTURES WITH ARCHITECTURAL DRAWINGS. THE MOUNTING HEIGHT FOR DEVICES SHALL BE AS INDICATED BELOW, UNLESS OTHERWISE NOTED. MOUNTING HEIGHTS ARE TO CENTER OF DEVICE, UNLESS OTHERWISE NOTED. MATCH MOUNTING HEIGHT OF EXISTING DEVICES IF APPLICABLE. GENERAL RECEPTACLES (COMMERCIAL) @18" AFF ABOVE COUNTER RECEPTACLES AND SWITCHES @ 2" ABOVE COUNTER OR BACKSPLASH TO BOTTOM OF DEVICE (COORDINATE WITH ARCHITECT) LIGHT SWITCHES @ 44" AFF LIGHT SWITCHES IN BATHROOMS @ 44" AFF TELEPHONE OUTLETS @ 18" AFF TELEPHONE OUTLET (WALL MOUNTED) 44" AFF CLOCK OUTLETS @ 7'-6" AFF TV OUTLETS (COMMERCIAL) @ 18" AFF DATA/PHONE OUTLETS (COMMERCIAL) @ 18" AFF LOCATE WALL SWITCHES ON STRIKE SIDE OF DOOR WITH EDGE OF WALL PLATE 3 INCHES FROM EDGE OF DOOR FRAME. WHERE LOCATIONS ARE INDICATED OTHERWISE, NOTIFY ARCHITECT TO OBTAIN DIRECTION PRIOR TO PROCEEDING WITH WORK. PROVIDE "IN-USE" WEATHERPROOF COVER FOR EXTERIOR RECEPTACLES. COMPLY WITH ADA STANDARDS FOR MOUNTING HEIGHTS AND LOCATIONS. DEVICES IN THE SAME LOCATION AND AT THE SAME MOUNTING HEIGHT SHALL BE MOUNTED UNDER A COMMON WALL PLATE. DISTRIBUTION EQUIPMENT PROVIDE DISTRIBUTION PANELS, DISCONNECTS, CONTACTORS, ETC. OF VOLTAGE, AMPERAGE, PHASE, AND SHORT-CIRCUIT RATINGS AS INDICATED ON PLANS. TERMINATIONS SHALL BE RATED 75°C MINIMUM CU/AL. EQUIPMENT SHALL BE FULLY-RATED FOR THE AVAILABLE FAULT CURRENT UNLESS A SERIES-RATED COMBINATION IS SPECIFICALLY NOTED ON PLANS. FUSES SPECIFIED ARE AS MANUFACTURED BY BUSSMANN. THE SAME CLASS OF FUSE AS MANUFACTURED BY LITTELFUSE AND GOULD-SHAWMUT MAY BE SUBSTITUTED. ENCLOSURES FOR EQUIPMENT AND DEVICES SHALL BE SUITABLE FOR THE INSTALLED LOCATION. PROVIDE 3 5/8" DEEP LOAD CENTERS FOR PANELS INSTALLED IN 4" STUD WALLS. PROVIDE PANELBOARDS FOR ALL OTHER INSTALLATIONS, UNLESS OTHERWISE NOTED. PROVIDE A 3/4"C FROM PANEL ENCLOSURES TO NEAREST ACCESSIBLE CEILING SPACE FOR EACH (3) SPARE BREAKERS AND SPACES IN PANELBOARDS AND LOAD CENTERS THAT ARE RECESSED IN A WALL. PROVIDE PANELS AND SWITCHBOARDS BUSSING AND FINGERS TO ACCOMMODATE BREAKERS OR SWITCHES IN ALL AVAILABLE SPACES. PROVIDE DOOR-IN-DOOR HINGED COVER FOR PANELBOARDS. PROVIDE A LISTED BREAKER-TIE OR MULTI-POLE BREAKER FOR EACH MULTIWIRE (SHARED NEUTRAL) BRANCH CIRCUIT. PROVIDE DISTRIBUTION EQUIPMENT AS MANUFACTURED BY AMERICAN MIDWEST POWER, SQUARE D, ELECTRO-MECHANICAL INDUSTRIES, CUTLER-HAMMER, SIEMENS, ERICKSON ELECTRIC, GE OR METRON. THE MOUNTING HEIGHT FOR DISTRIBUTION EQUIPMENT SHALL BE AS INDICATED BELOW, UNLESS OTHERWISE NOTED. PANELS/LOADCENTERS - 6' AFF MAX TO CENTER OF TOP HANDLE CT CANS - 2' AFF MIN, 6' AFF MAX TO CENTER OF CTs DISCONNECT SWITCHES - 6'-6" AFF MAX TO CENTER OF HANDLE SINGLE UTILITY METER - 4' MIN, 6' MAX TO CENTER OF METER CLEAN EXPOSED SURFACES AND CHECK TIGHTNESS OF ELECTRICAL CONNECTIONS FOR EQUIPMENT TO BE REUSED. REPLACE DAMAGED CIRCUIT BREAKERS AND PROVIDE CLOSURE PLATES FOR VACANT POSITIONS IN EXISTING PANELS. PROVIDE CONCRETE PAD FOR FLOOR AND GROUND MOUNTED ELECTRICAL EQUIPMENT. LABEL SERVICE EQUIPMENT WITH MAXIMUM AVAILABLE FAULT CURRENT AND DATE CALCULATION WAS PERFORMED. IDENTIFICATION FOR ELECTRICAL SYSTEMS PROVIDE BRASS TAG (ATTACHED WITH BRASS SCREWS), INDICATING UNIT SERVED ON SERVICE DISCONNECTS, FEEDER DISCONNECTS, AND METERS SERVING MULTI-TENANT FACILITIES. PROVIDE A TYPED PANEL SCHEDULE WITH LOAD DESCRIPTIONS FOR PANELS AFFECTED BY THIS PROJECT. PROVIDE A PHENOLIC LABEL ON EACH NEW OR RENAMED PANEL INDICATING THE PANEL NAME. PROVIDE IDENTIFICATION LABELS OR HANDWRITTEN TEXT USING INDELIBLE MARKER TO IDENTIFY CIRCUITS ENCLOSED IN BOXES. USE IDENTIFICATION LABEL OR ENGRAVED FACEPLATE TO IDENTIFY BRANCH CIRCUITS FEEDING RECEPTACLES AND SWITCHES. PROVIDE IDENTIFICATION ON INSIDE SURFACE OF FACEPLATE FOR RECEPTACLES AND SWITCHES IN PUBLIC AREAS OR IN AREAS AS DIRECTED BY ARCHITECT OR OWNER. USE IDENTIFICATION LABEL TO IDENTIFY RECEPTACLES PROTECTED BY UPSTREAM GFI PROTECTION. LABEL CONDUCTORS AND CABLE WITH POWER SOURCE AND CIRCUIT NUMBER OR OTHER REQUIRED DESIGNATION. USE WRAP-AROUND SELF-ADHESIVE VINYL CLOTH, WRAP-AROUND SELF-ADHESIVE VINYL SELF-LAMINATING, HEAT-SHRINK SLEEVE, PLASTIC SLEEVE, PLASTIC CLIP-ON, OR VINYL SPLIT SLEEVE TYPE MARKERS SUITABLE FOR THE CONDUCTOR OR CABLE TO BE IDENTIFIED. USE FACTORY PRE-PRINTED OR MACHINE-PRINTED TEXT, ALL CAPITALIZED UNLESS OTHERWISE INDICATED. IDENTIFY EACH PIECE OF ELECTRICAL EQUIPMENT WITH AN IDENTIFICATION NAMEPLATE. PROVIDE THE FOLLOWING INFORMATION ON THE NAMEPLATE: DISTRIBUTION EQUIPMENT: AMPERE RATING, VOLTAGE, PHASE, POWER SOURCE, AND LOADS BEING SERVED. ENCLOSED SWITCHES AND CIRCUIT BREAKERS: AMPERE RATING, VOLTAGE AND PHASE, POWER SOURCE, LOAD BEING SERVED. CONDUCTOR INSULATION SHALL BE COLOR CODED AS FOLLOWS: 240/120V, 1Ø: PHASE A - BLACK; PHASE B - RED IDENTIFY EXISTING ELEMENTS TO REMAIN THAT ARE NOT ALREADY IDENTIFIED. PROVIDE TYPEWRITTEN CIRCUIT DIRECTORY TO IDENTIFY LOADS SERVED FOR PANELBOARDS AND LOAD CENTERS. MECHANICAL AND PLUMBING EQUIPMENT REFERENCE MECHANICAL AND PLUMBING (M/P) PLANS FOR EXACT LOCATION AND REQUIREMENTS OF MECHANICAL EQUIPMENT. ELECTRICALLY OPERATED EQUIPMENT SHOWN ON THE M/P PLANS AND NOT SHOWN ON THE ELECTRICAL PLANS WILL REQUIRE ELECTRICAL SERVICE. CONTACT ELECTRICAL ENGINEER FOR CONNECTION REQUIREMENTS PRIOR TO BID. THE COST FOR THIS WORK SHALL BE INCLUDED IN THE BID. VERIFY EQUIPMENT NAMEPLATE DATA (VOLTAGE, PHASE, FLA, MCA, MOCP, ETC.) PRIOR TO ROUGH-IN. NOTIFY ELECTRICAL ENGINEER IN WRITING OF ANY DISCREPANCIES WITH THESE DRAWINGS IMMEDIATELY AND PRIOR TO COMMENCING ANY FURTHER WORK. STARTERS FOR MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH THE EQUIPMENT. REFERENCE MP PLANS FOR CONTROL REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT. PROVIDE CONDUIT, WIRE, AND DEVICES FOR MECHANICAL EQUIPMENT CONTROLS. PROVIDE SHOP DRAWING(S) FROM EQUIPMENT SUPPLIER(S) FOR REVIEW PRIOR TO STARTING WORK. ROUTE CIRCUITS THROUGH EQUIPMENT CONTROL PANELS, PROVIDE CONTROL WIRING, AND INTERLOCKS PER THE MECHANICAL SPECIFICATIONS AND EQUIPMENT SHOP DRAWINGS. REFERENCE MECHANICAL DRAWINGS FOR LOCATIONS OF FIRE SMOKE DAMPERS. PROVIDE 120V, 20A CIRCUIT TO FIRE SMOKE DAMPERS, AND PROVIDE EITHER DUCT OR SMOKE DETECTORS AS REQUIRED. CONNECT DETECTORS TO FIRE ALARM SYSTEM IF APPLICABLE. RETURN AIR SYSTEMS OVER 2000CFM: PROVIDE SMOKE/DUCT DETECTOR IN RETURN AIR SYSTEM TO SHUT DOWN AIR DISTRIBUTION SYSTEM UPON ACTIVATION OF SMOKE/DUCT DETECTOR. CONNECT DETECTORS TO FIRE ALARM SYSTEM IF APPLICABLE. PROVIDE EW201B FOR MECHANICAL EQUIPMENT CONTROLLED BY A TIME SWITCH. PROVIDE CONTACTORS RATED FOR THE MECHANICAL LOAD BEING CONTROLLED. MAKE FINAL ELECTRICAL CONNECTIONS TO M/P EQUIPMENT. UTILIZATION EQUIPMENT VERIFY EQUIPMENT NAMEPLATE DATA (VOLTAGE, PHASE, FLA, MCA, MOCP, SCCR, ETC.) PRIOR TO ROUGH-IN. NOTIFY ELECTRICAL ENGINEER IN WRITING OF ANY DISCREPANCIES WITH THESE DRAWINGS IMMEDIATELY AND PRIOR TO COMMENCING ANY FURTHER WORK. MAKE FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT. TELEPHONE, DATA, AND CABLE OUTLETS PROVIDE A 4"X4" JUNCTION BOX WITH SINGLE-GANG PLASTER RING AND A 3/4" CONDUIT WITH PULL STRING TO NEAREST ACCESSIBLE CEILING SPACE FOR EACH WALL MOUNTED PHONE, DATA, AND CABLE OUTLET. PROVIDE A FLUSH FLOOR BOX WITH FLUSH FACE PLATE AND A 3/4" CONDUIT WITH PULL STRING TO NEAREST ACCESSIBLE CEILING SPACE FOR EACH FLOOR MOUNTED PHONE, DATA, AND CABLE OUTLET. KITCHEN REQUIREMENTS REFERENCE ARCHITECTURAL AND KITCHEN EQUIPMENT DRAWINGS FOR EXACT LOCATION AND REQUIREMENTS OF KITCHEN EQUIPMENT. VERIFY KITCHEN EQUIPMENT NAMEPLATE DATA (VOLTAGE, PHASE, FLA, MCA, MOCP, ETC.) PRIOR TO ROUGH-IN. KITCHEN RECEPTACLE GFCI PROTECTION: PROVIDE GFCI PROTECTION FOR 1Ø RECEPTACLES RATED 120V, 208V AND 240V, 50A OR LESS AND 3Ø RECEPTACLES RATED 208V AND 240V, 100A OR LESS. PROVIDE GFCI RECEPTACLE, FACELESS GFCI DEVICE FEEDING STANDARD RECEPTACLE, OR GFCI CIRCUIT-BREAKER. THE GROUND-FAULT CIRCUIT-INTERRUPTER SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION. KITCHEN EQUIPMENT AND LIGHTING CIRCUITS LOCATED UNDER A HOOD, WITH A HOOD EXTINGUISHING SYSTEM, SHALL BE ROUTED VIA A CONTACTOR CONTROLLED BY THE HOOD EXTINGUISHING SYSTEM. THE HOOD EXTINGUISHING SYSTEM SHALL DISCONNECT POWER AND GAS FROM EQUIPMENT AND LIGHTING UNDER THE HOOD UPON ACTIVATION OF THE HOOD EXTINGUISHING SYSTEM. POWER TO EQUIPMENT UNDER HOOD SHALL REMAIN OFF UNTIL MANUALLY RESET. LIGHTING PROVIDE LIGHT FIXTURES AS INDICATED ON LIGHTING PLAN OR FIXTURE SCHEDULE. REFERENCE ARCHITECTURAL DRAWINGS FOR LUMINAIRE SCHEDULE. NOTIFY ELECTRICAL ENGINEER OF ANY DISCREPANCIES WITH THESE DRAWINGS. THE MOUNTING HEIGHT FOR LIGHT FIXTURES SHALL BE AS INDICATED ON THE FIXTURE SCHEDULE, ARCHITECTURAL ELEVATIONS, OR AS SHOWN BELOW, UNLESS OTHERWISE NOTED. MATCH MOUNTING HEIGHT OF EXISTING LIGHT FIXTURES IF APPLICABLE. INSTALL EXIT AND EMERGENCY LIGHTS @ 6" BELOW CEILING TO TOP OF FIXTURE WITH A MAXIMUM MOUNTING HEIGHT OF 10' AFF. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH LIGHTING CIRCUIT. CONNECT EXIT AND EMERGENCY LIGHTING TO NON-SWITCHED LEG OF LOCAL LIGHTING CIRCUIT UNLESS OTHERWISE NOTED. MAKE CONNECTIONS TO LIGHT FIXTURES USING BUILDING WIRE WITH INSULATION SUITABLE FOR TEMPERATURE CONDITIONS WITHIN THE LUMINAIRE. MAINTAIN THE FIRE RATING OF THE ASSEMBLY (CEILING OR WALL) IN WHICH LIGHT FIXTURES ARE TO BE INSTALLED. PROVIDE FIRE-RATED FIXTURES OR PROVIDE BOX AROUND FIXTURES AS MANUFACTURED BY TENMAT, EZ BARRIER OR EQUAL. PROVIDE IC RATED FIXTURE FOR FIXTURES IN CONTACT WITH INSULATION. IF REQUIRED, PROVIDE TENTING AROUND FIXTURES TO MAINTAIN REQUIRED CLEARANCE FROM INSULATION FOR NON-IC RATED FIXTURES. PROVIDE 30A LIGHTING CONTACTOR WITH NUMBER OF POLES AS REQUIRED FOR LIGHTING CONTROLLED BY A TIME SWITCH OR PHOTOCELL. TIME SWITCH: TORK EWZ201 TIME SWITCH WITH PHOTOCELL: TORK DGLC SERIES COORDINATE THE PLACEMENT OF SUPPORTS, ANCHORS, ETC. REQUIRED FOR MOUNTING LIGHT FIXTURES. COORDINATE COMPATIBILITY OF LUMINAIRES AND ASSOCIATED TRIMS WITH MOUNTING SURFACES AT INSTALLED LOCATIONS. CLEAN ALL EXTERIOR AND INTERIOR SURFACES OF EXISTING FIXTURES TO BE REUSED. REPLACE LAMPS AND BROKEN COMPONENTS. LAMP BURN-IN: OPERATE LAMPS AT FULL OUTPUT FOR MINIMUM OF 100 HOURS OR PRESCRIBED PERIOD PER MANUFACTURER'S RECOMMENDATIONS. REPLACE LAMPS THAT FAIL PREMATURELY DUE TO IMPROPER LAMP BURN-IN. JUST PRIOR TO SUBSTANTIAL COMPLETION, REPLACE ALL LAMPS THAT HAVE FAILED. COORDINATE FINAL LIGHT SWITCH LOCATIONS WITH OWNER AND CONFIRM LOCATIONS DURING BOX WALK. UNLESS OTHERWISE NOTED, PROVIDE FACTORY-PAINTED STEEL POLE ON CONCRETE FOUNDATION FOR EXTERIOR POLE MOUNTED FIXTURES. COORDINATE PLACEMENT OF POLES AND ASSOCIATED FOUNDATIONS WITH UTILITIES, CURBS, SIDEWALKS, TREES, WALLS, FENCES, STRIPING, ETC. ELECTRIC UTILITY COMPANY SUBMIT ELECTRICAL DRAWINGS AND SERVICE APPLICATION TO ELECTRIC UTILITY COMPANY PRIOR TO STARTING ANY WORK. COORDINATE WITH THE ELECTRIC UTILITY COMPANY TO ARRANGE FOR PERMANENT AND TEMPORARY ELECTRICAL SERVICE TO BE PROVIDED TO THE SITE AS REQUIRED. OBTAIN WRITTEN APPROVAL FROM THE LOCAL ELECTRIC UTILITY COMPANY INDICATING THAT THE SERVICE DESIGN IS ACCEPTABLE. PROVIDE LETTER TO ELECTRICAL ENGINEER PRIOR TO PURCHASING ANY ELECTRICAL SERVICE EQUIPMENT OR STARTING ANY WORK ON THE ELECTRICAL SERVICE. NOTIFY ELECTRICAL ENGINEER IMMEDIATELY OF ANY DESIGN CHANGES REQUESTED BY THE UTILITY COMPANY. DETAIL NOTE REVISION TAG UTILIZATION EQUIPMENT TAG MECHANICAL/PLUMBING EQUIPMENT TAG DESIGNATIONS X X X xx X DETAIL NOTE X XXX NOTE: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT LEGEND CIRCUIT RUN IN OR UNDER FLOOR OR IN EARTH POWER DISTRIBUTION CIRCUIT RUN CONCEALED IN WALL OR CEILING CIRCUIT RUN SURFACE MOUNTED MAGNETIC STARTER OR CONTACTOR ELECTRIC METER - UTILITY METER U.O.N. CONTACT - NO - # INDICATES ASSOC. COIL PULLOUT FUSED DISCONNECT SWITCHBOARD OR EQUIPMENT ENCLOSURE NON-FUSED DISCONNECT SWITCH TRANSIENT VOLTAGE SURGE SUPPRESSER FLEXIBLE CONNECTION TO EQUIPMENT HOMERUN - ARROWS INDICATE # OF PHASE COND. PAD MOUNTED TRANSFORMER OVERHEAD SERVICE ENTRANCE CONDUIT STUB - CAP IF UNDERGROUND OR T J/B OR J OR M OR CT M TRANSFORMER JUNCTION BOX TRANSFER SWITCH CONDUIT UP, CONDUIT DOWN FUSED DISCONNECT SWITCH CURRENT TRANSFORMER COMBINATION STARTER GROUNDING ELECTRODE GENERATOR MOTOR NF TVSS CIRCUIT BREAKER SWITCH WITH FUSE OVERLOAD RELAY ELECTRICAL PANEL OR E G SWITCH CONTACT - NC - # INDICATES ASSOC. COIL KKI 2 KIRK KEY INTERLOCK - # INDICATES RELATED KEYS M2 COIL - # INDICATES ASSOCIATED CONTACT M2 M2 ~+ - AC POWER SOURCE DC POWER SOURCE SPD SURGE PROTECTIVE DEVICE ABBREVIATIONS WP UON UC GFI/GFCI ILT N OR (N) R OR (R) O.C. TL ISC IG G OR GND AC AFI/AFCI FLR CLG E OR (E) CD AFF AIC AFG LET-THROUGH FAULT CURRENT (RMS SYMMETRICAL) PERSONNEL GROUND-FAULT PROTECTION (.5ma) AVAILABLE FAULT CURRENT (RMS SYMMETRICAL) ISOLATED GROUND UNDER COUNTER WEATHER PROOF UNLESS OTHERWISE NOTED ON CENTER RELOCATE GROUND TWIST-LOCK NEW AMPERE INTERRUPTING CAPACITY (MINIMUM RATING) ARC-FAULT CIRCUIT INTERRUPTER ABOVE FINISHED FLOOR ABOVE FINISHED GRADE FLOOR MOUNTED CEILING MOUNTED ABOVE COUNTER EXISTING CORD DROP ST SHUNT-TRIP NO/NC NORMALLY OPEN/NORMALLY CLOSED ATS AUTOMATIC TRANSFER SWITCH XP EXPLOSION PROOF TR TAMPER RESISTANT DT DUST TIGHT SCCR SHORT CIRCUIT CURRENT RATING GF/GFPE EQUIPMENT GROUND-FAULT PROTECTION WM PM12 DEVICES WIREMOLD - AS SPECIFIED ON PLAN FLUSH FLOOR OUTLET (DEVICE AS INDICATED) PLUGMOLD - # INDICATES RECEPTACLE SPACING O.C. SINGLE RECEPT. - 125V, 15A/20A AS REQUIRED DUPLEX RECEPT.- 125V, 15A/20A AS REQUIRED FOURPLEX RECEPT. - 125V, 15A/20A AS REQUIRED HALF-SWITCHED RECEPT. - 125V, 15A/20A AS RQ'D SPECIAL PURPOSE RECEPT. - V AND A AS REQUIRED THERMOSTAT DAMPER MOTOR BELL, CHIME, OR BUZZER H HOOD CONNECTION T D PP POWER/DATA POLE (DIVIDED) POWER POLE CLOCK RECEPTACLE PP G FACELESS GFCI OUTLET - READILY ACCESSIBLE P POWER OUTLET FURNITURE WHIP IBTD INTERSYSTEM BONDING TERMINATION DEVICE 20A DUPLEX - WIRELESS PLUG LOAD CONTROL LOWERCASE LETTER ADJACENT TO FIXT. INDICATES CONTROL K OR EM NL TRACK LIGHT LIGHTING BATTERY PACK EXIT LIGHT WALL MOUNTED FIXTURE SURFACE FLUORESCENT RECESSED WALL WASHER FLUORESCENT STRIP LIGHT RECESSED FLUORESCENT RECESSED FIXTURE INDICATES INTEGRAL EMERGENCY POWER BATTERY BATTERY PACK EXIT/EM COMBINATION LIGHT BATTERY PACK EMERGENCY LIGHT LIGHT - TYPE INDICATED ON SCHEDULE LIGHT - TYPE INDICATED ON SCHEDULE KEYLESS PORCELAIN LAMP HOLDER - 150W SURFACE MOUNTED FIXTURE INDICATES NON-SWITCHED NIGHT LIGHT UPPERCASE LETTER ADJACENT TO FIXT. INDICATES FIXTURE TYPE OR OR REMOTE EMERGENCY LIGHT BATT BATTERY PACK FOR REMOTE EMERGENCY LIGHT PENDANT MOUNTED FIXTURE EMWP EXTERIOR EMERGENCY EGRESS LIGHT OR OR AUDIO/VISUAL AUDIO/VISUAL EQUIPMENT RACK - WALL MOUNTED AUDIO/VISUAL EQUIPMENT RACK - FLOOR MOUNTED SPEAKER - WALL MOUNTED MICROPHONE OUTLET - FLOOR MOUNTED VOLUME CONTROL MICROPHONE OUTLET - WALL MOUNTED SPEAKER - CEILING MOUNTED (FLUSH) M VC S S M CABLE/TV OUTLET PHONE/DATA FLUSH FLOOR OUTLET (DEVICE AS INDICATED) DATA OUTLET TELEPHONE OUTLET COMBINATION TELEPHONE/DATA OUTLET TELEPHONE TERMINAL CABINET TELEPHONE TERMINAL BOARD C COMMUNICATIONS OUTLET FURNITURE WHIP WIRELESS ACCESS POINT - CEILING UON 3 2 P 4 K T D LV D OR SWITCHES/CONTROLS OCCUPANCY SENSOR - CEILING MOUNTED VARIABLE SPEED MOTOR CONTROL SWITCH DIMMER SWITCH - WATTAGE AS REQUIRED PHOTOCELL PUSH BUTTON TIME SWITCH - TORK (DIGITAL) TO T S OCCUPANCY SENSOR - WALL MOUNTED EMERGENCY POWER-OFF SHUNT-TRIP THERMAL OVERLOAD SWITCH V OR V CB CIRCUIT-BREAKER SWITCH - 20A1P DIGITAL SWITCH PC DIGITAL SWITCH WITH RAISE/LOWER BUTTONS TS LCD TOUCHSCREEN - X = SCREEN SIZE X" SINGLE POLE SWITCH SWITCH WITH PILOT LIGHT KEY OPERATED SWITCH LOW VOLTAGE SWITCH MECHANICAL TIME SWITCH 3-WAY SWITCH 4-WAY SWITCH TWO POLE SWITCH DUAL-LEVEL SWITCHING (ALTERNATE LAMPS OR FIXTURES) OS OS OS OCCUPANCY SENSOR - CORNER MOUNTED - WALL OR CEILING # DIGITAL SWITCH - # = NUMBER OF BUTTONS DIGITAL LOAD CONTROL MODULE WITH 1 RELAY DIGITAL LOAD CONTROL MODULE WITH 2 RELAYS DIGITAL LOAD CONTROL MODULE WITH 3 RELAYS DIGITAL LOAD CONTROL MODULE WITH 1 RELAY & DIMMING DIGITAL LOAD CONTROL MODULE WITH 2 RELAYS & DIMMING OS OCCUPANCY SENSOR - LIGHT FIXTURE MOUNTED/INTEGRAL OS2 OCCUPANCY SENSOR - 2-POLE, WALL MOUNTED OS3 OCCUPANCY SENSOR - 3-WAY, WALL MOUNTED PS PHOTOSENSOR - CEILING MOUNTED PS PHOTOSENSOR - LIGHT FIXTURE MOUNTED/INTEGRAL LC1 LC2 LC3 LC1D LC2D OSD OCCUPANCY SENSOR - 0-10V DIMMING, WALL MOUNTED WIRELESS COMMUNICATIONS - ADDED TO DEVICE SYMBOL WAC WIRELESS AREA CONTROLLER OLC OUTDOOR LIGHTING CONTROLLER BRANCH-CIRCUIT WIRING SCHEDULE (UNLESS OTHERWISE NOTED) OVERCURRENT PROTECTION DEVICE RATING/ SETTING PHASE CONDUCTOR SIZE (CU) NEUTRAL CONDUCTOR SIZE (CU) (IF REQUIRED) EQUIPMENT GROUNDING CONDUCTOR SIZE (CU) CONDUIT SIZE 15 A #12 AWG #12 AWG #12 AWG 1/2" 20 A #12 AWG #12 AWG #12 AWG 1/2" 25 A #10 AWG #10 AWG #10 AWG 1/2" 30 A #10 AWG #10 AWG #10 AWG 1/2" 35 A #8 AWG #8 AWG #10 AWG 3/4" 40 A #8 AWG #8 AWG #10 AWG 3/4" 45 A #6 AWG #6 AWG #10 AWG 1" 50 A #6 AWG #6 AWG #10 AWG 1" 60 A #4 AWG #4 AWG #10 AWG 1 1/4" 70 A #4 AWG #4 AWG #8 AWG 1 1/4" 80 A #3 AWG #3 AWG #8 AWG 1 1/4" 90 A #2 AWG #2 AWG #8 AWG 1 1/2" 100 A #1 AWG #1 AWG #8 AWG 1 1/2" NOTES: 1. FOR MOTOR LOADS, USE MCA (MINIMUM CIRCUIT AMPACITY) TO SIZE PHASE AND NEUTRAL CONDUCTORS AND USE MOCP (MAXIMUM OVER-CURRENT PROTECTIVE DEVICE) TO SIZE EQUIPMENT GROUNDING CONDUCTOR. 2. INCREASE PHASE, NEUTRAL, AND EQUIPMENT GROUNDING CONDUCTOR SIZES BY 1 STANDARD CONDUCTOR SIZE PER EACH 75' OF CONDUCTOR LENGTH. INCREASE CONDUIT SIZE ACCORDINGLY. A A PROVIDE CLEAR SPACE EQUAL TO THE WIDTH OF EQUIPMENT OR 30", WHICHEVER IS GREATER. B PROVIDE THE FOLLOWING CLEAR SPACE IN FRONT OF EQUIPMENT: 3' FOR 0-150 L-G VOLTAGE AND 4' FOR 151-600 L-G VOLTAGE. C PROVIDE CLEAR SPACE, FOR THE WIDTH OF THE EQUIPMENT, FROM GRADE, FLOOR OR PLATFORM TO A HEIGHT OF 6-1/2' OR THE HEIGHT OF THE EQUIPMENT, WHICHEVER IS GREATER. D THE SPACE EQUAL TO THE WIDTH AND DEPTH OF THE EQUIPMENT AND EXTENDING FROM THE FLOOR TO A HEIGHT OF 6' ABOVE THE EQUIPMENT OR TO THE STRUCTURAL CEILING, WHICHEVER IS LOWER, SHALL BE DEDICATED TO THE ELECTRICAL INSTALLATION - NO PIPING, DUCTS, LEAK PROTECTION APPARATUS, OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION SHALL BE LOCATED IN THIS ZONE. SUSPENDED CEILINGS WITH REMOVABLE PANELS SHALL BE PERMITTED WITHIN THE 6' ZONE. SPRINKLER PROTECTION SHALL BE PERMITTED FOR THE DEDICATED SPACE WHERE THE PIPING COMPLIES WITH THIS SECTION. A DROPPED, SUSPENDED, OR SIMILAR CEILING THAT DOES NOT ADD STRENGTH TO THE BUILDING STRUCTURE SHALL NOT BE CONSIDERED A STRUCTURAL CEILING. E THE AREA ABOVE THE DEDICATED SPACE SHALL BE PERMITTED TO CONTAIN FOREIGN SYSTEMS, PROVIDED PROTECTION IS INSTALLED TO AVOID DAMAGE TO THE ELECTRICAL EQUIPMENT FROM CONDENSATION, LEAKS, OR BREAKS IN SUCH FOREIGN SYSTEMS. B C D D E E CLEAR SPACE/WORKING SPACE ABOUT ELECTRICAL EQUIPMENT THE FINAL LOCATION OF EQUIPMENT SHALL BE COORDINATED IN THE FIELD, PRIOR TO ROUGH-IN, TO MEET APPLICABLE LOCATION, HEIGHT AND CLEARANCE REQUIREMENTS. THE ELECTRICAL CONTRACTOR SHALL STOP WORK IMMEDIATELY, AND ADVISE OTHERS TO STOP WORK IF THERE IS A CONFLICT WITH THE ELECTRICAL CLEARANCE AND WORK SPACE REQUIREMENTS PER THE ABOVE INFORMATION AND THE NEC. D FRONT VIEW OF EQUIPMENT SIDE VIEW OF EQUIPMENT OS LC1 OS # WIRED OCCUPANCY SENSOR CONCEPTUAL WIRING DIAGRAMS OS CORNER MOUNT OCCUPANCY SENSOR - WATTSTOPPER OR EQUAL CEILING MOUNT OCCUPANCY SENSOR - WATTSTOPPER OR EQUAL. WALL SWITCH - WATTSTOPPER OR EQUAL. NUMBER BELOW SWITCH INDICATES QUANTITY OF SWITCH BUTTONS. OUT TO LOAD (ADD 0-10V OUTPUT IF DIMMING IS REQUIRED) ROOM CONTROLLER - WATTSTOPPER OR EQUAL. NUMBER INDICATES QUANTITY OF OUTPUT RELAYS, "D" INDICATES 0-10V DIMMING. DATA CABLE (TYPICAL) 20A CIRCUIT WALL SWITCH SENSOR - WATTSTOPPER OR EQUAL OUT TO LOAD 20A CIRCUIT Sheet Number: E1 Description Date 2020/04/06 BROTHERS BBQ FORT COLLINS NATHAN HALL ARCHITECTURE, LLC nathanwhall@outlook.com 501 S Taft Hill Rd Fort Collins, CO 80521 Kazin & Associates, Inc. Village Square at Lone Tree 9364 Teddy Lane, Ste #101 Lone Tree, CO 80124 © 2020 Phone: 720-489-1609 Fax: 720-489-1611 Project #: 20097 Consulting Electrical Engineers Est. 1984 1 AS NOTED 2020/04/22 2 AS NOTED 2020/07/10 N I Z A K . M D I V A D R E E N I G N E L A N O I S S E F O R P 20747 O D A R O L O C L I C E N S E D NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY DAVID KAZIN. LIMITED TO ELECTRICAL. 7-10-20