HomeMy WebLinkAboutAMIGOS AT SHIELDS PRELIMINARY PUD - 47 90A - CORRESPONDENCE - RESPONSE TO CITIZENDevelop*~-nt Services
Planning ►,cpartment
City of Fort Collins
July 3, 1991
Mrs. Emily Smith
Prospect -Shields Neighborhood Association
1000.West Prospect Road
Fort Collins, CO. 80526
Dear Mrs. Smith:
Per your request to keep your organization informed of development
potential in your neighborhood, I have enclosed a copy of the
Conceptual Review Staff Comments for Amigos Restaurant. The
proposed location is 1015 South Shields, currently a Texaco service
station.
Amigos Restaurant has retained the services of Vaught -Frye
Architects and Planners to investigate the feasibility of a drive
thru restaurant as a planned unit development at this location. At
present, Vaught -Frye has requested an "area of notification" map
from the Planning Department for a possible neighborhood meeting.
As yet, the neighborhood meeting has not been scheduled. Your
organization will be notified when this meeting is confirmed.
The Planning Department has not heard back from' the Mullaneys
regarding the parcel at the southwest corner of Prospect and
Shields. From all indications, it appears that the City Stormwater
Utility Department and the Mullaneys must come to terms on an
acquisition price for storm channel improvements before the parcel
is ready to be brought through the plan review process. Again,
your organization will be notified if a neighborhood meeting is
scheduled for this proposal..
Nor has the Planning Department heard back from the group
-- - - investigating multi -family housing on the 20 acres at Stuart and
Shields (old Pulse P.U.D.). This group, based out of Birmingham,
Alabama, is interested in providing upscale, secure, multi -family
units for college students. The group has done other projects in
other university settings across the county but has not reached any
final decision about locating in Fort Collins.
While it is unknown which of these projects will be submitted for
plan review, your organization should be aware that all three are
being vigorously analyzed for feasibility. We will keep you
informed as each project comes forward for Conceptual Review or for
a neighborhood information meeting.
Sincerely:
Ted Shepard
281 North College Avenue • P.O. Box 580 • ! Fort Collins, CO 80522-0580 • (303) 221-6750
y- 5
City of Fort Collins
June 27, 1991
Develop; it Services
Planning Department
Mr. Frank Vaught
Vaught - Frye Architects
2900 South College Avenue
Fort Collins, CO 80525
Dear Mr. Vaught:
For your information, attached is a copy of the Staff's comments concerning
Amigos at 1015 South Shields (Texaco), which was presented before the Conceptual
Review Team on June 24, 1991.
The comments are offered informally by Staff to assist you in preparing the
detailed components of the project application. Modifications and additions to
these comments may be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in
the review process, please feel free to call me at 221-6750.
Sincerely,
l
Ted Shepard
Project Planner
TS/d _.
Attachment
cc: Tom Peterson, Planning Director
Kerrie Ashbeck, Civil Engineer
Project Planner
File
281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750
CONCEPTUALO REVIEW
STAFF ;OMMENTS
MEETING DATE: June 24, 1991
ITEM: Amigos at 1015 South Shields (Texaco)
APPLICANT: Amigos Restaurant c/o Frank Vaught, Vaught - Frye
Architects, 2900 South College Avenue, Fort Collins, CO. 80525
LAND USE DATA: Reqilest for a drive-thru restaurant -on .59 acre
located at 1015 South Shields, currently a Texaco service station.
The zoning is B-L, Limited Business.
COMMENTS:
1. The City Light and Power Department has secondary overhead
power to the site. This line would have to be placed in an
underground conduit, located in a utility easement. This
modification would be at the developer's expense. A Commercial One
Form, "C-111, would have to be completed to determine entrance
capacity. The pad mounted transformer must be accessible from one
side by hard surface which may. feature an access gate. The
transfomer may be screened on three sides by landscaping or an
enclosure.
2. The existing water and sewer services to the Texaco are in
place. These may be used if adequate for Amigos' needs. A grease
trap must be added to the sanitary sewer located outside the
building.
3. The property is located in the Spring Creek drainage basin.
The drainage fees are $1,610 per developed acre. A Drainage'Report
and. Drainage and Grading -Plan are required. Onsite detention would..
be required. Erosion control must be.addressed in the Drainage
Report.
4. During review of the ,Texaco enlargement of a building
containing a non -conforming use, it was detemined that an offsite
drainage easement must be obtained from :adjacent- church.
Permission to grant-this•easement has not been forthcoming. The
Concer-n..o.f the church is long term maintenance. - t. .
5. The Poudre Fire Authority needs adequate turning radii in the
parking lot. Present radii look very tight and may not meet the
access requirements of the Fire Code. Fire sprinklers would
alleviate the problem with tight turning radii. If the existing
fire hydrant is within 400 feet, then a new hydrant will not be
required.
6. Removal of Texaco's underground gasoline storage tanks will
require a permit from the Poudre Fire Authority. For further
information, please contact Warren Jones,'221-6570.
7. The zoning is B-L, Limited Business. Standard and fast food
restaurants are allowed in the B-L. The drive-thru component will
trigger the request to be processed as a planned unit development.
A neighborhood meeting will be required.
8. With only one street frontage, the property is eligible for
only one free-standing sign. Since menu boards are classified as
free-standing, a variance would have to be obtained from the Zoning
Board of Appeals to allow two free-standing signs. For further
information, please contact Dan Coldiron, 221-6760.
9. There are serious traffic related issues with a drive-thru
restaurant at this location. Presently, Shields Street is at over
capacity at the Shields/Elizabeth intersection. Northbound traffic
turning west on Elizabeth stacks back past University. There are
no .plans to signalize University. As a result, left turns into and
out of the site would be prohibited. If left turn exits from the
drive-thru lane were not restricted, then there would be excessive
stacking back past the pick-up window, the menu board, and into the
parking lot.
10. A Traffic Impact Analysis would be required. Such a study
should meet the standard format and criteria of the City
Transporation Department. Please contact Eric Bracke, 221-6608 for
further information.
11. The Transportation Department strongly encourages the
applicant to consider the location of the campus and promote
pedestrian versus vehicular access.
12. A "Choices 95" project for 1994 would construct a right turn
lane for eastbound Elizabeth to southbound Shields. Also, a signal
at Lake Street is planned. Again, there are no plans to signalize
Shields at University.
13. The Street Oversizing Fee for a drive-thru restaurant is
$14,005 per acre.
14. The Auto Related and Roadside Commercial, point chart of the
L.D.G.S. awards points for being ..."contiguous to and functionally
a part of a neighborhood.or community regional shopping center...".
At present, 'the property is not considered to be eligible for these
points. Staff would consider granting these points if Amigos and
the Campus West Center were to cooperate on curb cut consolidation
and upgrading the landscaping of .the center. Evidence of such
cooperation must be in writing and landscaping must be of a
sufficient quantity genuinely upgrade the center.
15. The site plan, as submitted, indicates 16 feet long parking
stalls,. and 20 feet wide parking lot drive aisles. These
dimensions are below standards and would not be allowed.
16. Vehicular overhang areas should not be so small that
landscaping cannot grow. These areas should be widened and planted
with landscape materials.
17. Have you considered the level of bicycle traffic in the area?
Have modifications been made to accommodate bike traffic, bike
parking, and bike drive-thru capability?
18. Please be aware that the alley between Texaco and Campus West
shops is on Texaco's property. This alley is used by the shops for
dumpster and loading access. It is strongly suggested that Amigos
meet with the property mananger and the tenants of Campus West to
determine the impacts of drive-thru restaurant on the alley.
19. Has Amigos considered purchasing the vacant property to the
south? If this property is acquired, then primary vehicular access
could be gained from a non -arterial and points could be awarded on
the Auto Related and Roadside Commercial point chart. In addition,
the extra land could be -used to provide a much greater measure of
landscape buffering than presently indicated on the sketch plan.
This area would allow for outdoor dining.
20. If Amigos seeks points for energy conservation., then a report
must be submitted and certified by a' mechanical engineer.
demonstrating how the criteria has been met. Such a report will be
evaluated by the Building Inspection Division.
21. Please be aware that as a Planned Unit Development, the
project will be held to a higher standard than that allowed under
the "use by right" zoning. For example, Staff would look for total
screening of rooftop mechanical equipment, total screening of the
menu board, building foundation shrubs along the drive-thru lane,
a free-standing monument sign mounted on a pedestal of similar
material as the building. The size, location, and character of the
readerboard would be closely reviewed, as would the use of exposed
neon as an- architectural, ,feature. Landscaping, berming, and
setbacks would be closely scrutinized to minimize the impact on the
streetscape and the adjacent, residentially zoned property.
22. A neighborhood meeting will be required. __