For your information, attached is a copy of the Staff's comments concerning
Amigos Drive-Thru Restaurant at Shields, presented before the Conceptual Review
Team on July 6, 1992.
The comments are offered informally by Staff to assist you in preparing the
detailed components of the project application. Modifications and additions to
these comments may be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in
the review process, please -feel free to call me at 221-6750.
Sincerely,
Ted Shepard
Senior Planner
- TS/gjt _
Attachment
cc: Tom Peterson, Planning Director
Kerrie Ashbeck, Civil Engineer
Transportation Department
Project Planner
File
281 North College Avenue • P.O. Box 580 • Fort Collins, CO 805221-0580 • (303) 221-6750
CONCEPTUAL REVIEW STAFF COMMENTS
MEETING DATE: July 6, 1992
ITEM: Amigos Drive-Thru Restaurant at Shields
APPLICANT: Mr. Michael Henninger, Amigos Growth Management
Corporation, 2546 S. 48th, #61 P.O. Box 6189, Lincoln, NE. 68506.
Represented by Mr. Frank Vaught, Vaught -Frye Architects and
Planners, 1113 Stoney Hill Drive, Fort Collins, CO. 80525.
LAND USE DATA: Request for a 2,610 square foot drive-thru
restaurant on .59 acre at 1015 South Shields. The site is
currently a Texaco service station. The curb cut on Shields is now
consolidated with Campus West Shops. The zoning is B-L, Limited
Business.
COMMENTS:
1. -The Light and Power Department will assess normal development
charges and site charges. A Commercial One (C-1) Form must be
completed by the electrical contractor to determine entrance
capacity. Power will likely be brought in from the northwest.
The existing overhead line will be replaced by underground
conduit for which an easement must be granted. The
transformer location should be coordinated with Light and
Power. It must be accessible from one side by minimum
clearances which may be in the form of a gate. The
transformer should be screened from view on three sides by
landscaping or an enclosure. It should not be located along
Shields.
2. The existing water and sewer services for Texaco may be used
- for Amigos. If a larger service is needed, the old service_
must be abandoned back to the main. A grease trap must be
installed on the sanitary sewer line, outside the building, in
a concrete vault. The Water and Sewer Department has a
specification on the grease trap, if necessary.
3. The nearest fire hydrant is located in .front of Columbine
Cablevision. This hydrant must be within a minimum of 400
feet in order to serve the property. If not, a hydrant may
have to be installed on the site..
4. The removal of the underground gasoline storage tanks will
require a permit from the Poudre Fire Authority. There have
not been any reports of leakage in this location. The
applicant is advised to conduct an environmental audit for
protection.
5. The site is zoned B-L, Limited Business, which allows standard
and fast food restaurants. This zone does not allow the
drive-thru component. Therefore, the request must be
considered as a Planned Unit Development..
6. The site is eligible for one, free-standing ground sign. A
menu board for the drive-thru is Considered a free-standing
sign. If two free-standing signs are requested, the second
sign_(menu board) is only permitted by a variance from the
Zoning Board of Appeals. Care should be taken so that the
menu board is screened from adjacent properties. Please
contact Dan Coldiron for details on the submittal to the
Z.B.A; for a variance request.
7. The site is located in the Spring Creek Drainage Basin with
fees of $1,610 per developed acre. It is believed that the
front half of the site drains to Shields, and the back half
drains to the northwest corner. Storm flows on the back half
must cross a portion of John the 23rd property in order to
reach the culvert. This must take place within an easement
granted by the property owner. During the approval process
for the Texaco, Enlargement of a Building Containing a Non -
Conforming Use, this easement was not granted.
8. Onsite detention is required for only the new impervious
surface area created. It is preferred that the detention
occur on the rear of the property.
9. Please be advised that there is a recurring problem with
standing water along the west property line. This is the area
of the alley that is used by trucks to serve the Campus West
Shops. Since the alley is used by trucks, a raised curb will
not be a viable solution. There is also an electrical switch
cabinet and transformer in this area. The issue of the
standing water should be resolved. Please contact Kathy
Nicol, Property Manager, 493-2782, to coordinate a solution to
the problem. _
10. A standard Drainage Report, Drainage and Grading Plan, and
Erosion Control Plan will be required.
11. The consolidated curb cut with Campus West Shops is an
improvement over the previous concept plan. A final Traffic
Impact Analysis will be required. There may be a problem with
two-way traffic in the Campus West Shops parking lot at the
joint curb cut. Cars exiting Campus West may experience
delays due to conflicts with right-in/right-out movements for
Amigos.
12. Additional bicycle parking is encouraged. Please investigate
adding more bike racks.
13. Please coordinate with Mark Sears, Project Engineer for the
Choices 195 capital construction project. The final design of
this project has not been selected yet. Final design may
include a bus pullout just south of the drive-thru exit lane.
14. A plat was prepared by Stewart and Associates for the Texaco
Enlargement project but was not filed. Please be sure that
the plat dedicates 50 feet for the west half of Shields
Street.
151. A standard set of utility plans will be required. ._A
Development Agreement will be required. The project will be
assessed a Street Oversizing Fee of $14,005 per acre.
16. The Engineering Department is concerned about the j-oint curb
cut. While Amigos is limited to right -in and right -out, the
Campus West traffic will allow southbound exits which may --
conflict with the right -in movement. Cars exiting both
projects may cause stacking back onto both properties: Left
exits must discouraged through good design since there will
not be a median in Shields. The Traffic Impact Analysis
should investigate this situation.
17. Please coordinate with Campus West on the removal of the
northbound Shields left turn into the joint curb cut. The
joint curb cut should belegally described in a cross -access
easement that is'recorded with the County.
18. Staff applauds the saving of the mature hedge and existing
trees on the south property line.
19. The parking lot and drive area should be treated with a
minimum of *6% interior landscaping. The street trees on
Shields should be of the same species.
20. The applicant should be advised that there is probably not
enough room on the site for both a child playground and the
outdoor dining patio. A child playground is inappropriate at
this location.
21. On June 24, 1991, the Staff reviewed a concept plan for a
larger Amigos on this site. During that review, Staff made a
comment regarding obtaining points for being "... contiguous
to and functionally a part of a neighborhood or community
regional shopping center..." Staff applauds the combining of
curb cuts and the indication of off -site landscaping to unify
and improve the Shields streetscape. Every effort to
cohesively unify these two projects would help promote the
objective behind the granting of the points. At the time of
Final, these off -site improvements should be acknowledged in
writing:
22. Staff remains concerned about the overall appearance and
quality of the project. Comment number 21 from the June 24,
1991 Conceptual Review is .repeated here to emphasize this
concern.
"Please be aware that as a Planned Unit Development, the
project will be held to a higher standard than that
allowed under the "use by right" zoning. For example,
Staff would look for total screening of rooftop
mechanical equipment, total screening of the menu board
from adjacent properties, building foundation shrubs
along the drive-thru lane, a free-standing monument sign
mounted on a pedestal of similar material as the
building. The size, location, and character of the
readerboard would be closely"reviewed,'-as would the use
of exposed neon as an architectural feature.
Landscaping, berming, and setbacks will be closely
scrutinized to minimize the impact on the streetscape and
the adjacent, residentially zoned property."
23. A neighborhood information meeting will be required. Our
records indicate that a neighborhood meeting was scheduled to
discuss the Texaco site on July 30, 1991.- This meeting was
canceled at the request of Amigos. The cancellation notice
indicated that a neighborhood meeting would be re -scheduled if
the project is submitted for formal review. The area
notification map is still part of the file and may be used to
update the affected property owner list.