HomeMy WebLinkAboutTACO BELL RESTAURANT PRELIMINARY AND FINAL PUD - 51-90A - CORRESPONDENCE - CORRESPONDENCE-CONCEPTUAL REVIEWDevelopL it Services
Planning Department
City of Fort Collins
September 10, 1991
Taco Caliente Inc.
c/o Al Hauser
Architecture One
150 East 29th Street
Palmer Gardens #200
Loveland, CO 80538
Dear Mr. Hauser:
For your information, attached is a copy of the Staff's comments concerning, Taco
Bell Restaurant and Wickersham House, that was presented before the Conceptual
Review Team on September 9, 1991.
The comments are offered informally by Staff to assist you in preparing the
detailed components of the project application. Modifications and additions to
these comments may, be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in
the review process, please feel free to call me at 221-6750.
Sincerely,
Ted Shepard
Project Planner — �-
TS/gjt
Attachment
cc: Tom Peterson, Planning Director
Kerrie Ashbeck, Civil Engineer
Project Planner
File
281 North College venue • P.P. Box 580 • Fort Collins, CO 80522-0580 • (301) 221-6750
CONCEPTUAL REVIEW STAFF COMMENTS
MEETING DATE: September 9, 1991
ITEM: Taco Bell Restaurant and Wickersham House (1530 and 1538
South College Avenue)
APPLICANT: Taco Caliente Inc., c/o Mr. Al Hauser, Architecture One,
150 East 29th Street, Palmer Gardens #200, Loveland, CO. 80538.
LAND USE DATA: Request to demolish the existing Taco Bell
_._structure at the northeast corner of South College Avenue and
Prospect Road, and to convert the existing home at 1530 South
College Avenue into a new Taco Bell restaurant featuring two drive
thru lanes and a.building addition on the east side.
rKel YT1TY6A 60 i_-13P
1. The City's Light and Power Department has installed an
electrical transformer along the alley on the northeast
portion of the site. This transformer should be granted an
easement by the property owner to the City for this placement.
Also, transformers are allowed to be screened, with
appropriate clearances, by a fence or landscaping. Access to
the transformer must be from hard surface from one side.
Normal development charges will apply. For further
information regarding electrical service, please contact Kevin
Westhuis, 221-6700.
2. The water and sewer taps for the existing restaurant should be
abandoned back to the main. The existing taps for the
Wickersham property should be upgraded to accommodate the
_____needs of the restaurant. A grease trap will be required to be
placed on the sanitary sewer line, outside the building —This-- - --
trap is to be a split vault. A detail of an acceptable trap
is enclosed. For further information on water and. sewer fees,
or grease trap installation, please call Mark Taylor, 221-
6681.
3. For purposes of storm drainage analysis, the existing Taco
Bell site will be considered an existing condition. A
Drainage .Report and Drainage and Grading Plan will be
required. Also, the new Erosion Control criteria has been
adopted so the Report should include information on how the
criteria will be addressed. The existing storm drainage
system in the area is at capacity so the site will be required
to detain any storm flows that are generated over and above
the existing condition. The fees in the Spring Creek Drainage
Basin are $1,610 per acre. For further information regarding
storm drainage issues, please call Glen Schlueter, 221-6589.
4. The Poudre Fire Authority has two issues: access and water
supply. The access looks fine as long as the parking lot
drive aisles and turning radii meet minimum standards. The
water supply cannot be obtained from the existing hydrant
south of Prospect. A new hydrant must be tapped along
College, north of Prospect, within 400 feet of the structure.
You are encouraged to place the hydrant north of the new
concrete installed on College Avenue this summer. For further
information, please call Warren Jones, 221-6570.
5. The Building Inspection Division advises that a new electrical
system be installed. Also, please verify the load bearing
capacity of the floor. Normal submittal requirements for
building permit review will apply. Please contact the health
department for information on the latest health code
requirements. For further information, please contact Sharon
Getz, 221-6760.
6. The zoning is R-H which does not allow drive-thru lanes.
Therefore, the request must be processed as a P.U.D. by the
criteria of the.Land Development Guidance System.
7. The face of the menu boards should not be visible from
adjacent property lines. The free-standing sign should be a
monument sign, not a pole sign. Signage placement and size
will be reviewed as part of the P.U.D.
8. The issue of the median on Prospect to control the right-
in/right-out curb cut will have to be discussed in more detail
with the City Engineer and the Transportation Department. The
City has a capital improvement plan to widen the intersection
tentatively scheduled for 1993. In the interim, the curb cut
may have to be controlled with a "pork chop" island. Or,
depending on an evaluation by the Transportation Department,
a median may have to be constructed at the time of
development.
9. The existing Traffic Impact Analysis should be updated
reflecting the new development proposal.
10. The parking stalls facing north may be too close to the
College Avenue curb cut and cause conflicts. Staff, however,
recognizes that parking on the site is tight. Variances may
have to be obtained from the Development. Review Engineer prior
to approval. Please contact Mike Herzig, 221-6750, for
further information.
11. The width of the sidewalk on College and Prospect was an issue
during the last submittal. At that time, the width was agreed
to be reduced from 7 feet to 6 feet in the interest of
creating additional room for landscaping or tree grates. Six
feet is considered to be acceptable given this situation.
12. The two drive cuts on College Avenue will need a State Highway
Access Permit. The Development Review Engineer will
facilitate this application process after final design is
determined.
13. Staff is concerned about the sight distance at the alley/
drive-thru intersection with Prospect. It is doubtful that
this intersection will meet current standards. Staff is
willing to work with the applicant to customize a design that
will work best under the circumstances.
14. Improvements in the public right-of-way (sidewalk, curb,
gutter, ramps, etc.) may be eligible for reimbursement.
15. The new development will be subject to the Street Oversizing
Fee of $14,005 per acre.
16. Please indicate on the P.U.D. the number of existing trees on
the site, the number to saved, and the number to be removed.
17. A drive-thru restaurant does not meet the Auto Related and
Roadside Commercial point chart of the Land Development
Guidance System. By saving the existing house, however, Staff
is willing to recommend a variance to the Planning and Zoning
Board. The level of quality brought to the site will
contribute to the likelihood of the Board granting the
variance. You are encouraged to landscape the store with
planters, provide parking lot landscaping, and provide tree
grates along areas where surface treatments will be difficult.
Also, you are encouraged to keep exterior lighting to
sensitive levels with down directional fixtures which do not
spill illumination offsite. Fencing and landscaping should be
designed to buffer adjacent residences with an appropriate
mass to mitigate sound impacts.
18. The "Planning Objectives" should also address how the new
addition will blend in with the original structure.
19. The fence on the north property line should be attractive so
as not to be objectionable to the adjacent property. Also,
the fence should be landscaped with shrubs to soften the
appearance. Please keep in mind the impacts of headlights of
cars using the drive-thru lanes and provide landscaping
accordingly.
20. The landscaped strip between the westerly drive-thru lane and
the 6 parking stalls facing east should feature sufficient
vertical elements to provide an effective visual separation.
21. Bicycle racks should be provided out of the traffic flow but
not installed in such a way as to inhibit pedestrian movement.
22. It is recommended that a neighborhood meeting take place to
update the affected property owners on the latest plans.
Also, the issue of hours of operation, especially on Sundays,
should be resolved. Please advise the Planning Department of
a date that would be convenient to meet. The Planning
Department will set the time, date, location, and facilitate
the meeting.
2,
PLAN VIEW
L8
MANHOLE COVER
GROUT WATER LEVELI r 2' I
NOTES:
1. SECONDARY COMPARTMENT HAS VOLUME EQUAL
TO 1/3 OF TOTAL CAPACITY.
2. ALL PIPE AND FITTINGS TO BE CAST IRON,
3 INCH MINIMUM DIAMETER.
3. WALLS AND BOTTOM REINFORCED THROUGHOUT
WITH 2 X 16 6/10 REMESH.
4. COVERS TO BE REINFORCED LONGITUDINALLY
WITH NO. 6 REBAR ON 6' CENTERS, NO. 4
REBAR ON 6' CENTERS WIDTHWISE AND NO. 8
REBAR DIAGONALLY AROUND THE ACCESS HOLES.
5. CLEAN OUT SHALL BE AN IRON BODY FERRULE
WITH BRASS SCREW PLUG.
6. VENT PIPE SHALL BE CAST IRON TO A POINT
6' ABOVE GROUND.
7. CHECK WITH SUFPLIER FOR EXACT DIMENSIONS.
JT
PIPE O.D.+2'
1I N.
6'
ROOF LINE
— JOIN VENTS 1' ABOVE GRADE
CLEANOUT TO GRADE
—F /— LONG SWEEP WYE
WATER
CAPACITY
APPROX.
GALLONS
GREASE
CAPACITY
APPROX.
CUBIC FT.
DIMENSIONS
TWO COMPARTMENT TANK
INCHES
A
B
C
D
E
F
G.
320
17
48
72
22
32
30
44
24
500
32
48
72
36
46
44
58
24
780
47
48
96
40
50
48
62
20
1060
74
72
102
34
44
42
56
30
1250
87
80
112
35
43
41
57
1 36
TYPE A GREASE INTERCEPTOR
_ CITY OF FORT COLLINS SEWER, CONSTRUCTION APPROVED:. DETAIL
O
�— DATE: v/15/90
WATER UTILITIES DETAILS
f ilc nI Purl Cnl lies
DI\r;ti�n� BY : SC