Loading...
HomeMy WebLinkAboutFAIRVIEW PUD PHASE FOUR AMENDED FINAL - 52 90A - CORRESPONDENCE - SUPPLEMENTAL INFORMATIONEngineering Associates Project No. PLA - 204 - 96 May 31, 1996 Mr. John Freeman Architecture One, Architects and Planners, P.C. 150 East 29th Street, Suite 200 Loveland, Colorado 80538 Re: Proposed C. B. POTTS Clubhouse Micro -brewery, Fort Collins, Colorado Dear Mr. Freeman, As requested this office has investigated the status of existing facilities to determine if additional site work or utility extensions may be required to serve the subject site. The building was originally constructed in the mid-1980's to be used as a "Duds `N Suds" laundromat. The parking lot located to the North of the structure was in place at the time that the building was constructed. The site is a part of the "Fairview - P.U.D." The following have been determined based upon the City records: Water: The building is served by a two (2) inch diameter water service. The existing service should provide adequate capacity for the proposed micro -brewery. Sewer: The sewer service line discharges into a manhole on the eight (8) inch diameter sewer located at the East side of the building. Food preparation does not occur in the building. Residues from cleaning the brewing equipment and sediment removed during the brewing process will not be discharged into the sewer system. Therefore, there is no need for a new service line or sediment trap. Drainage: The surface drainage for the site is directed to catch basins located in the parking lots -to the North, —East and -South of the building. The proposed addition will replace existing paved parking lot and sidewalk with roof and structure. A minor amount of landscaping is to be added to the site along the front of the proposed addition. Recent construction of the storm drain outfall line for the "Potts - P.U.D." has redirected the outlet for the parking lot located at the South side of the building. This construction will eliminate the storm water discharge into the detention area located at the rear of the Diamond Shamrock convenience store. Therefore, due to the recent construction that has alleviated an existing problem and the fact that there will be no increase in impervious area, no change in the amount of storm water run-off is anticipated and no additional improvements should be required. Civil and Environmental Engineering Consultants 150 E. 29th Street. Suite 225 Loveland, Colorado 80538 Telephone: (970) 663-2221 Page 2 May 31, 1996 Project No. PLA - 204 -96 C. B. POTTS Clubhouse, Fort Collins, Colorado Parking: Parking is provided by the existing lots to the North, East and South. The proposed construction will reduce the seating capacity of the `Clubhouse' by approximately sixteen seats. Therefore, no additional parking is anticipated. We sincerely hope that this information will assist you. If you should have any questions or desire additional information, please feel free to contact this office. Respectfully Submitted, MESSNER Engineering Associates i G Dennis R. Messner, P.E. Engineering Associates LE171FER OF TRANSMITTAL TO: COMMUNITY DEVELOPMENT Date: May; 31, 1996 281 N. COLLEGE AVE. Proj. No: PLA - 204 - 96 P. 0. BOX 580 . Re: C.B. Potts Clubhouse FORT COLLINS, COLORADO 80522-0580 Fort Collins, Colorado ATTN: KERRIE ASHBECK, ENGINEERING DIVISION The following material is being transmitted on this date: QUANTITY 5 Comments: DESCRIPTION Copies of letter regarding: water & sewer service, drainage and parking. The above listed item(s) are being forwarded for the City's use and records. If you should have any questions or desire additional information, please feel free to contact this office. Forwarded via: DELIVERY Respectfully Submitted, MESSNER Engineering Associates By-. �` ' X- Dennis R. Messner, P.E. cc: John Freeman, Architecture One 150 East 29th Street, Suite 238 Loveland, Colorado 80538 Telephone: (970) 663-2221 FAX: (970) 663 - 0368 WHEATL _ . . * ! {f ':� ,..� _ i to 3�. ' ,y ��it-$; � • tlr vri} t , a G < w.. �, F� ' y .l Ti• �, .I � J� +' z � 1.�xi; by44 ri? a►R' K If it 1' +' '. t J 1'✓.y � .'t J 'l }, hl' l� i vl },,��. � • -:.• .c �`f�EJ r � •' ! R�.•: " -.1 L1 t 4.St` .� K� y.' y~7 r INT 1f j r Yij r'a s 01 It t 1• I ` , f r � � . � I . I , I • i � f ' : � '. � ( f r 1 f r ( 1 1 � ' •. ♦ , k � ' ♦ �.1 I� t �.� _I '`f r�1j `r t I� } f• {' # Y • '•t� ? ,�``. r _ _ y. �•.��• ii� .j 11_t ' ''. 1- i i 71 I - �•i \' I t �' i � - 0 DEG lEX AUGER DIRECTION VENT TUBE IB' DIA BIN 270 DEG 90 DEG 4• FILL LINE TOP ID VIEW GLASS OSHA LADDER/CAG OPTIONAL I80 G SHOW CLOCKING OF TUBES, VEN S, LADDERS, LEVEL INDICATORS DEPENDING ON WHICH FEATURES YOU CHOOSE, ALL OPTIONS I TRUCK FILL ILINE 765 CLR, 41 DIA 10' 22' RECOMMENDED VENT LINE WITH PNEUMATIC FILL %2E v )Ed GLASS I� s DEG CONE; Al I CAMLOCK? II Tr BOJ RAM INTERNATIONAL 06 19 96 NOTES: 1) BOOT DISCHARGE FOR 3.5" FLEX AUGER 2) WHITE ENAMEL EXTERIOR J) OSHA LADDER AND CAGE OPTIONAL 4) NO SIESMIC OR WIND ROMTS ASSUMED BRATNEY EQUIPMENT CO.