HomeMy WebLinkAboutNITTMAN SUBDIVISION - FDP200008 - SUBMITTAL DOCUMENTS - ROUND 3 - RESPONSE TO STAFF REVIEW COMMENTSFort Collins
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6689
970.224.6134-tax
fcgov.com/developmentreview
August 21, 2020
Brett Barrow
Creative Angle Builders LLC
PO Box 307
Laporte, CO 80535
RE: Nittman Subdivision, FDP200008, Round Number 2
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of Nittman Subdivision. If you have questions about any
comments, you may contact the individual commenter or direct your questions through your
Development Review Coordinator, Todd Sullivan via phone at 970-221-6695 or via email at
tsullivan@fcgov.com.
Comment Summary:
Department: Development Review Coordinator
Contact: Todd Sullivan, 970-221-6695, tsullivan@fcgov.com
Topic: General
Comment Number: 1
Comment Originated: 05/26/2020
I will be your primary point of contact throughout the Development Review and
Permitting process.
Please reach out to me with any questions or concerns you may have, need
additional meetings with project reviewers, or general assistance throughout the
process.
Please include me in all email correspondence with other reviewers, and keep
me informed of any phone conversations. Thank you!
Comment Number: 2
Comment Originated: 05/26/2020
As part of your resubmittal you will respond to the comments provided in this
letter. This letter is provided to you in Microsoft Word format. Please use this
document to insert responses to each comment for your submittal, using a
different font color. When replying to the comment letter please be detailed in
your responses, as all comments should be thoroughly addressed. Provide
reference to specific project plans or explanations of why comments have not
been addressed, when applicable.
Page 1 of 6
Comment Number: 3
Comment Originated: 05/26/2020
Resubmittals are accepted any business day of the week, with Wednesday
noon being the deadline for routing that same week. When you are ready to
submit your formal plans, please make an appointment with me at least 24
hours in advance.
Comment Number: 4 Comment Originated: 05/26/2020
05/26/2020: "FOR HEARING' comments will need to be addressed and
resolved prior to moving forward with scheduling the Administrative Hearing.
Staff will need to be in agreement that the project is ready for hearing
approximately 3-5 weeks prior to the hearing to make the appropriate
arrangements and meet notification requirements.
Department: Planning Services
Contact: Shawna Van Zee, 970-224-6086, svanzee@fcgov.com
Topic: Site Plan
Comment Number: 2 Comment Originated: 05/26/2020
08/21/2020: FOR HEARING:
See redlines for site plan.
Creative Angle Builders (CAB) Response: Redlines on site plan have been addressed.
Department: Engineering Development Review
Contact: Marc Virata, 970-221-6567, mvirata@fcgov.com
Topic: General
Comment Number: 3
Comment Originated: 05/25/2020
08/18/2020: FOR HEARING:
Xcel is now added to the plat. Have they provided a letter of intent being ok with
the concept prior to hearing?
CAB Response: Xcel has provided a Will Serve letter, and that letter is on file with Todd Sullivan
05/25/2020: FOR HEARING:
It is believed that Xcel Energy would need to sign the plat for the establishment
of easements crossing their existing easement. Xcel should also be providing
either an OK comment and/or a letter of intent not objecting to the plat going to
hearing.
CAB Response: Xcel has provided a Will Serve letter, and that letter is on file with Todd Sullivan
Comment Number: 4
Comment Originated: 05/25/2020
08/21/2020: INFORMATION ONLY: (updated comment)
The site plan information now known provides some general utility information. It
sounds like the intent is to more formalize this after approval and not have the
site plan show the designs as for construction with approvals by the
FCLWD/SFCSD. Under this premise, Engineering would require drawings
during the building permit stage that show the design and would have City
Engineering and FCLWD/SFCSD approvals.
08/18/2020: INFORMATION ONLY:
Page 2 of 6
The applicant indicated that FCLWD/SFCSD provided a will serve letter. If the
intent is to move forward with the plat approval without any utility design as part
of this process, the applicant is recognizing that design information on where
and how utility services from FCLWD/SFCSD will need to be reviewed and
approved by the City in the future and permitting for street cuts would be
required.
05/25/2020: FOR HEARING:
There does not appear to be any information showing existing and/or proposed
utilities. Where/how will water/sewer be provided?
CAB Response: Utilities will be designed as a part of the builder permit review process, not this subdivision
Comment Number: 6 Comment Originated: 08/18/2020
08/18/2020: FOR HEARING:
Pleasant Valley & Lake Canal and Trilby Lateral Ditch are now signatories to
the plat, have we received comment from them prior to hearing?
CAB Response: Trilby has provided written clearance, and that clearance has been provided to Planning.
Clearance from Pleasant Valley & Lake Canal Company is forthcoming.
Department: PFA
Contact: Jim Lynxwiler, 970-416-2869, Lynxwiler@poudre-fire.org
Topic: General
Comment Number: 1 Comment Originated: 05/25/2020
08/19/2020: Repeat of earlier comment
05/25/2020: FOR HEARING: DEAD-END FIRE LANES
The proposed Emergency Access Easement (EAE) creates a dead-end fire
lane of approximately 240 feet in length with no turnaround. As currently shown,
this configuration would not be acceptable. Dead-end fire access roads in
excess of 150 feet in length shall be provided with an approved area for turning
around fire apparatus. As access to both properties will be served by this EAE
dedication, the recommended solution is to create a hammerhead style
turnaround that overlaps with the drive connection proposed on Lot 1. Feel free
to contact me to discuss.
CAB Response: The intent is to utilize the turnaround on the new property as the EAE. That portion of the
driveway has been added to the EAE, and from our understanding, the dimensions and turning radii meet
the requirements.
Comment Number: 2 Comment Originated: 05/25/2020
08/19/2020: Repeat of earlier comment
05/25/2020: FOR HEARING: FIRE LANE SPECIFICATIONS
Plan approval requires that additional information be provided so as to ensure
the fire lane is being constructed to minimum specifications (provided
previously). Details to be noted on the site plan. Fire lane specifications
provided below.
CAB Response: The intent is to utilize the turnaround on the new property as the EAE. That portion of the
driveway has been added to the EAE, and from our understanding, the dimensions and turning radii meet
the requirements.
Comment Number: 3 Comment Originated: 05/25/2020
08/19/2020: Repeat of earlier comment
Page 3 of 6
05/25/2020: FOR HEARING: REQUIRED WATER SUPPLY
Current code requires a fire hydrant, capable of providing 1000 gpm at 20 psi
residual pressure to be located within 400 feet of any residence. For the
purposed of this section, this distance is measured along an approved path of
vehicle travel. The closest available hydrant is located on Scenic Drive to the
east, at a distance of approximately 635 feet from the proposed residence and
approximately 725 feet from the existing residence at 1000 Scenic Drive.
> In order to satisfy current fire code requirements, the installation of a fire
hydrant is required. Location TBD. The alternative to installing a hydrant is to
install a residential fire sprinkler system in the new home as an offset to the
hydrant requirement.
> The existing residence at 1000 Scenic Drive is non -compliant with regard to
water supply requirements: however, this condition will be considered
pre-existing and will not be subject to the hydrant requirement unless further
development is proposed on Lot 1. The installation of a hydrant (as noted
above) would be recommended (but not required) so as to serve both newly
created Lots by this subdivision.
> Either a new fire hydrant shall be noted on the updated plans or the plans
shall note that construction of a residence on Lot 1 will have a fire sprinkler
requirement attached to the building permit.
CAB Response: As previously discussed, a new fire hydrant will be proposed with building permit review to
ensure adequate water supply for both residences.
Comment Number: 4 Comment Originated: 05/25/2020
08/19/2020: Repeat of earlier comment
05/25/2020: FOR HEARING: ADDRESS POSTING
New and existing buildings shall have approved address numbers placed in a
position that is plainly legible, visible from the street fronting the property, and
posted with a minimum of four -inch numerals on a contrasting background. This
requirement shall apply to both properties (existing and proposed). As access
to both lots shall be shared by the same driveway, the addresses shall also be
posted at the driveway connection at Scenic Drive.
CAB Response: We have no concern with this requirement and while the new property will be addressed
during building permitting and inspection, the existing property will be verified and/or updated accordingly
Comment Number: 5
Comment Originated: 08/17/2020
08/17/2020: PRIOR COMMENTS
Review Summary: Fire department comments from last round of review were
not addressed. All comments remain outstanding and active.
CAB Response: We believe that all comments have now been responded too, though most are for
consideration during building permit review, not subdivision.
Department: Technical Services
Contact: Jeff County, 970-221-65887 icounty@fcgov.com
Topic: General
Comment Number: 4 Comment Originated: 08/17/2020
08/17/2020: FOR FINAL APPROVAL:
If the Existing/Proposed Conditions Map is serve as a Site Plan, the line over
text issues need to be corrected as marked. See redlines.
Page 4 of 6
CAB Response: Line -over -text issues have been addressed.
Topic: Plat
Comment Number: 1 Comment Originated: 05/21/2020
08/17/2020: FOR FINAL APPROVAL:
Please make changes as marked. If changes are not made or you disagree
with comments, please provide written response of why corrections were not
made. Please provide any responses on redlined sheets and/or in response
letter.
CAB Response: All redlines have been addressed
05/21/2020: FOR FINAL APPROVAL:
Please make changes as marked. If changes are not made or you disagree
with comments, please provide written response of why corrections were not
made. Please provide any responses on redlined sheets and/or in response
letter.
CAB Response: All redlines have been addressed
Department: Environmental Planning
Contact: Scott Benton, sbenton@fcgov.com
Topic: General
Comment Number: 2
Comment Originated: 08/17/2020
INFORMATION ONLY: If planned construction is expected to be near the
existing wetlands on the western edge of the property, I can assist with
delineating them to avoid any potential impacts that would necessitate US Army
Corps of Engineers involvement.
CAB Response: Scott Benton met with CAB onsite, and we appreciate the input and help
Department: Forestry
Contact: Nils Saha,
Topic: General
nsaha@fcgov.com
Comment Number: 2
Comment Originated: 08/18/2020
8-18-2020: INFORMATION ONLY
Thank you for showing the existing tree locations. City Forestry recommends
retaining significant trees to the extent reasonably feasible.
Comment Number: 3 Comment Originated: 08/18/2020
08/18/2020: INFORMATION ONLY
Is there any additional landscaping proposed for the additional lot?
CAB Response: No additional landscaping is proposed as a part of this subdivision
Comment Number: 4
Comment Originated: 08/18/2020
08/18/2020: INFORMATION ONLY
City Forestry recommends reviewing and including the City of Fort Collins Tree
Protection Notes on the Landscape plan. Please contact Nils Saha
(nsaha@fcgov.com) or the development review coordinator to obtain these
notes.
CAB Response: No landscape plans are proposed at this time as this is a subdivision, not a building permit
review
Page 5of6
Department: Internal Services
Contact: Russell Hovland, 970-416-2341,
Topic: Building Insp Plan Review
Comment Number: 1
rhovland@fcgov.com
Comment Originated: 08/18/2020
08/18/2020: All new and existing buildings must maintain the minimum fire
separation distance to new and existing property lines and new structures must
comply with the adopted IRC building code.
CAB Response: Any new structures shown on the site plan are for demonstration purposes only. Setbacks
and code considerations are expected to be covered and addressed as a part of the building permit review
process.
Department: Outside Agencies
Contact: Nate Ensley, ,
Topic: General
Comment Number: 1
Comment Originated: 05/21/2020
05/21/2020: Fort Collins - Loveland Water District and South Fort Collins
Sanitation District has no comments for the subdivision. Included as a separate
document is a copy of the "Will Serve" letter issued for this property.
Page 6 of 6