HomeMy WebLinkAboutPEDERSEN TOYOTA VOLVO SAAB PUD PRELIMINARY AND FINAL - 26 91 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSITEM NO. 7
MEETING DATE FL, Ai
STAFF Kirsten Whetstone
City of Fort Collins PLANNING AND ZONING BOARD
STAFF REPORT
PROJECT: Pedersen Toyota Volvo Saab PUD Preliminary and
Final- #26-91
APPLICANT: Sinnett Builders, Inc.
c/o Dana Lockwood- Architect
420 S. Howes, Suite 107
Fort Collins, CO 80521
OWNER: Gerry Pedersen
Colorado Import Motors
1113 N. College Avenue
Fort Collins, CO 80524
PROJECT DESCRIPTION:
This is a request for a Preliminary and Final PUD for a 27,222
square foot auto dealership building, for auto sales and service,
on a 2.79 acre site located at the northwest corner of College
Avenue and Kensington Drive. The property is zoned H-B, Highway
Business.
RECOMMENDATION: Approval
EXECUTIVE SUMMARY:
The applicant proposes a 27,222 square foot auto sales and service
building on this site. The project scores 58% on the Auto -Related
and Roadside Commercial Point Chart. A minimum of 50% is required
for approval. The site gains access off of Kensington Drive.
There is no direct access off of College Avenue. The perimeter of
the site has been creatively landscaped to provide good visual
screening and buffering of the car lot from the street frontages,
while at the same time meeting the visibility needs of such a use.
Interior landscaping exceeds the minimum standards of the City
Parking Code and is an attractive combination of evergreen and
deciduous trees and shrubs. The PUD is considered compatible with
the surrounding area.
DEVELOPMENT SERVICES 300 LaPorte Ave. P.O. Box 580 Fort Collins. CO 80522-0580 (303) 221-6750
PLANNING DEPARTMENT
Intended Future Ownership of P.U.D.:
Intended future ownership of the P.U.D. is intended to
remain with the current owners of Colorado Import Motors.
The dealership will operate under the new name of PEDERSEN
TOYOTA VOLVO SAAB. No change in ownership is anticipated in
the near future.
Estimate of Employees:
Colorado Import Motors currently employs approximately 44
persons. The maximum number of employees, following
implementation of this PEDERSEN TOYOTA VOLVO SAAB P.U.D., is
anticipated to be approximately 56 persons.
Erosion Control During Construction;
During construction operations the current City of Fort
Collins Standards for erosion control shall be adhered to.
Measures to inhibit and/or eliminate erosion runoff onto
adjacent City rights -of -way or other properties adjacent
shall include temporary barriers, such as straw bales, other
temporary drainage containment structures, proper location
of earth stockpiles and earth berming. Erosion control
planning and proper sequencing of construction activities
are to be observed.
Description of Rationale Behind Decisions and Choices:
Colorado Import Motors (soon to be doing business as
Pedersen Toyota Volvo Saab) is an established and successful
business. However, the business has outgrown it's current
facilities. The decision to pursue a new location is based
on a direct and real need to improve service to it's
clientele, improve it's ability to stock and display
inventory (autos), and improve visibility in the community.
The proposed South College Avenue site offers convenient
access, sufficient lot size, and is located quite
appropriately for its' auto related services.
The proposed exterior architecture design concept is
intended to meet certain tangible objectives, including
recognition, consistent use of color, materials that are
durable and easy maintenance. These address certain
franchise image objectives mandated by the auto
manufacturers.
Foundation landscape plantings are proposed at designated
areas adjacent tall elements of the proposed building. Of
primary concern was the scale and visual impact of the
massive service portion of 'the building,.highly visible from -
College Avenue. An landscaped elevated auto display is
proposed. It is to be bermed and landscaped, thereby
softening and reducing the scale of the otherwise massive
structure beyond.
It is no secret that a significant aspect of any auto
dealership, in business, is to market and sell automobiles.
This merchandise must be'inventoried and displayed. The
display of these automobiles, as products, is very important
to this business. However, the proposed site plan mitigates
a_conti.nuous_patte.r_n_of d_i.splay_ed_autos on College Avenue,
yet satisfies a basic need to display those autos. The plan
incorporates landscaped islands located at the perimeter and
within the interior of parking areas. A small number of
display parking spaces (two) are turned 90 degrees and
backed up by landscaped islands. These islands soften and
shade hard surface areas in addition to breaking up an
otherwise continuous pattern of cars. Orienting these
islands parallel to College Avenue increases the landscape
exposure of landscaping to this arterial.
It should be noted that it is very important to this
business that the designated address for this project be a
South College number.
Land Use Conflict Mitigation:
This proposed project is an auto dealership planned in a
Highway Business (HB) zone. The site is greater than two
acres and is•contiguous to existing urban development with
no apparent critical conflicts. Visual and functional
interaction between this project and the existing.
development will be minimal. Pedersen Toyota Volvo Saab
P.U.D. is consistent with the Land Use Policies Plan in
regard to infil development.
The project is not located at a corner of two arterials,
instead taking access from a non -arterial street, Kensington
Drive. The proposed parking and new curb cut locations are
compatible to the South College Corridor Plan and will not
conflict with the implementation of that plan.
The proposed new development will incorporate the entire
site, which is currently void of trees and landscaping.
Landscape buffers will be provided at the site's perimeter
in addition to added landscaping at the site's interior to
soften the effect of the hard surfacing and facilities
required for the intended use. Of key concern is mitigating
the effect of the development from College Avenue, parkways
and landscaping buffers are to be provided.
The proposed new building for the P.U.D. orients the auto
service functions of the facility to the rear (west) of the
site. This allows for the typically lower and less massive
portions of the facility to be located to the front, helping
to screen the utilitarian functions of the operation from
College Avenue.
The architectural quality of
will be compatible with exist
This new construction will en
the proposed new construction
ing construction in the area.
area, helping to shield the existing
the west.
e appearance or Lne
mini -storage units to
Design Methods to Reduce Energy Consumption:
The proposed new construction construction will incorporate
large W & V) overhangs, at walls with significant glazed
surfaces, which shade glazed openings and reduce solar gain
in summer months, thereby reducing cooling demand.
Energy efficient, gas fired HVAC systems will be utilized.
All glazed surfaces will be thermal paned in frames with
thermal breaks. The proposed new structure will also be well
insulated.
Development Schedule and Phasing:
It is the desire of the Owner to construct the project in
one (1) phase. It is the Owner's intent to begin
construction as soon as possible following the Planning and
Zoning Board's final approval for the project. Construction
completion is anticipated for early to mid 1992.
ALL DEVELOPMENT: NUMBERED CRITERIA CHART
ALL CRITERIA APPLICABLE CRITERIA ONLY
Nil the ahteflon
M the rntenon opWknbb9 be fate
CRITERIONYes No If no, please explain
NEIGHBORHOOD COMPATABILITY
1, Social Compatabllity
2. Neighborhood Character
3. Land Use Conflicts
I •J..... T-. 1--A
PLANS AND POLICIES
5. Comprehensive Plan
PUBLIC FACILITIES & SAFETY
6. Street Capacity
11. Water Hazards
RESOURCE PROTECTION
14. Wildlife
15. Historic(
16. Mineral
ENVIRONMENTAL ST
Access
4
r. 1791
AUTO -RELATED AND
ROADSIDE COMMERCIAL
POINT CHART D
For All Criteria
Applicable Criteria Only
Criterion
tit
CrMerion
Applkdble
Yes NO
1 11 111 IV
Circle
the
Correct Score
Multiplier
Points
Earned
Ixll
Maximum
Applicable
Points
a. Not at Two Arterials
X
X1(f
0
2
4
b. Part of Planned Center
X
X
2
01
3
0
6
c. On Non -Arterial
X
X
L2
0
4
8
d. Two Acres or More
X
X
n2
0
3
(0
6
e. Mixed -Use
X
X
2
0
3
Q
6
f. Joint Parking
1 1
2
0
3
-
g. Energy Conservation
X
112131410
2
8
h. Contiguity
X
X
f,
0
5
-/d
10
i. Historic Preservation
1
2
0
2
j.
1
2
0
-k. --
1-
-2--0-
V.
2
0
Totals ,2�
vI vi
Percentage Earned of Maximum Applicable Points V/VI = VII
vu
W
d
x
C�
J
W
G
W
x
F-
MEMORANDUM
To: Dana Lockwood, Architect
Eric Bracke, Fort Collins Transportation Planner
Fort Collins Planning Staff
From: Matt Delich
Date: May 6, 1991
Subject: Colorado Imports Traffic Study (FILE 9122MEM1)
Colorado Imports has proposed to locate an automobile
sales and service business on South College Avenue north of
Kensington Drive in Fort Collins, Colorado. In February,
1988, The Auto Avenue Site Access Study was submitted for auto
related retail uses on the same parcel. This memorandum
serves as an update of that site access study.
The Auto Avenue Site Access Study assumed various auto
retail uses: (1) special retail; (2) convenience store with
gas; and (3) a quick lube store. The trip generation for that
study was estimated using Trip Generation, 4th Edition, ITE.
The trip generation for the Auto Avenue uses. are shown to
Table 1. Table 2 shows the trip generation from Colorado
Imports use. The auto dealership is listed in Trip
Generation, 4th Edition as Land Use Code 841 -- New Car Sales.
The following statement defines New Car Sales, from Trip
Generation, 4th Edition. "New car sales facilities are
generally located as strip development along major arterial
streets which already have a preponderance of commercial
development. Generally included are auto services and parts
sales along with a sometimes substantial used -car operation.
Some dealerships also include leasing activities and truck
sa-l-es-and-ser_vi.aing_."The_pr_o.po.sed Colorado Imports appears
to closely fit this definition. The trip generation shown in
Tables 1 and 2 depict daily trips, noon peak hour trips, and
afternoon peak hour trips. A trip is defined as having either
an origin or destination at the proposed site. Comparing
Table 1 and Table 2 shows that the proposed auto dealership
is less intense from a travel perspective than the uses
proposed on the Auto Avenue site. The daily trips in Table
2 is 52 percent of the Auto Avenue trip generation. The noon
peak hour in Table 2 is 81 percent of Table 1 and the
afternoon peak hour in Table 2 is 50 percent of Table 1. The
percentage change in travel is significant; however, the
absolute change in the number peak hour trips is very small
compared to the existing and future traffic volumes on College
Avenue and Harmony Road. The changes in travel caused by this
change of use are not significant enough to warrant a complete
revision to the Auto Avenue Site Access Study.
I
Table 1
Trip Generation
(from Auto Avenue Site'Access
Study)
Daily Noon
Peak
P.M.
Peak
Land Use
Trips Trips
Trips
Trips
Trips
in
out
in
out
Special Retail
780 30
30
40
40
C-store/gas
1500 61
61
76
76
Lube Store
200 10
10
10
10
TOTAL
2480 101
101
126
126
Table 2
Trip Generation
(for Colorado Imports Auto Dealership)
Dai-1-y Noon-P-eak P_..M.._P_eak
Land Use Trips Trips Trips Trips Trips
in• out in out
Colorado Imports 1290 91 72 54 71
New Car Sales (27.2 ksf)
Two accesses were proposed to the Auto Avenue site: (1)
a full -turn access from Kensington Drive, and (2) a right -in
only from College Avenue. Colorado Imports is proposing one
access from Kensington Drive. Kensington Drive is a short
(470 feet long). street which connects College Avenue and Mason
Street. An existing mini -storage complex, west of the site,
gains access from Kensington Drive at the present time.
Kensington Drive is 36 feet wide. College Avenue has three
through traffic lanes in each direction adjacent to this site.
There is a 14-16 foot painted median which serves as a left -
turn lane for several street and driveway intersections in
this area. A southbound right -turn auxiliary lane has
recently been built on the west side of College Avenue
extending from Harmony Road to the south property line of the
Target Store.
The peak hour traffic counts at the College/Harmony and
Harmony/Mason intersections used in the Auto Avenue Site
Access Study are provided in Appendix A. The City of Fort
Collins obtained morning, noon, and afternoon peak hour
traffic counts at the College/Harmony intersection in 1969.
These are shown in Figure 1. Comparing the noon and afternoon
peak hour traffic for 1987 and 1989 reveals the following:
(1) the north leg has decreased by 6 percent; (2) the south
leg has increased by 2 percent; (3) the west leg has increased
by 29 percent; and (4) the east leg has increased by 17
percent. These varying rates of change were used to develop
traffic projections for the short range (1995) and long range
(2010) futures.
The site plan for.Colorado Imports is shown in Figure 2.
The single point of access proposed to this site is located
170 feet west.of the west curb of College Avenue. It is
slightly offset (2 feet) from an access shown in the Auto
Avenue Site Access Study for a convenience/gas store on the
south side of Kensington Drive. This amount of offset is
insignificant and will not affect operation or safety. .
Using the 1989 peak hour traffic volumes shown in Figure
1 and the existing geometrics•, the College/Harmony
intersection operates acceptably. Calculation forms are
provided in Appendix B. Lengths of some phases were adjusted
as necessary to improve the operation in this analysis. The
phase lengths may not be exactly as described in the Fort
Collins VMS. In the afternoon peak hour, some movements on
the east and west legs 'are in level of service E; however, the
overall operation of the intersection is in level of service
D.
During the summer of 1991, the City of Fort Collins will
construct a raised median on College Avenue north and south
of Harmony Road. The new approach geometry,on both legs of
College Avenue will be: one right -turn lane, two through
lanes, and two left -turn lanes. Subsequent analyses performed
cl) rn
co cc co
to O N
r � �
O CO
Ch CM N
N CO N
r � �
N 't
CO U) CA
In 11 r
68/117/157
539/259/295
98/.109/91
188/236/296
198/222/555
211/175/313
tr HARMONY
r W co
ao O LO
rcoN
r co N
CO N
co d' co
r co O
rr` N
AM/NOON/PM
h I
1989 PEAK HOUR TRAFFIC Figure 1
Pedersen Toyota Volvo Saab PUD - Preliminary & Final, #26-91
June 24, 1991 P & Z Meeting
Page 2
COMMENTS:
1. Background•
The surrounding zoning and land uses are as follows:
N: H-B; Target Store (Target PUD)
S: H-B; Proposed Amoco Convenience Center and existing McDonalds
restaurant (Gateway at Harmony Road PUD)
E: b-p; undeveloped and College Inn Motel
h-b; Pavilion Shopping Center (Ft. Collins Retail Center PUD)
W: H-B; mini storage units (Mini-U-Storage PUD)
The property is zoned H-B, highway business. Auto sales is not a
use by right in this zone and therefore this request must be
reviewed as a PUD. This site is a replat of lots 1 and 2 of the
Auto Avenue Mall PUD which was given final approval by the Planning
and Zoning Board on May 23, 1988 for various auto related uses,
including a convenience/gas station. Auto Avenue Mall PUD
replatted the one lot U-Haul PUD which was approved August 27, 1984
for a 43,700 square foot U-Haul rental/repair facility with
household storage.
The site is located on the west side of College Avenue north of
Kensington Drive. The South College Avenue Highway Access. Control
Plan was adopted in 1988 and affects potential access points to
this site. There will be no access off of College Avenue. All
access will be off of Kensington Drive which will eventually be
signalized.
2. Land Use•
The proposed use consists of a 27,222 square foot building on a
2.79 acre site. The Preliminary and Final PUD scores 58% on the
Auto -Related and Roadside Commercial Uses point chart of the Land
Development Guidance System. This exceeds the minimum required
score of 50%. Points were earned for the following lettered
criteria: a) not at two arterial streets, c) access on a non -
arterial street, d) a site of 2.0 or more acres and h) contiguity
to existing development.
The site is located at the corner of College Avenue and Kensington
Drive where access is from Kensington Drive only. Kensington Drive
is not an arterial street. The site is contiguous to existing and
proposed urban development on the north, west, south and part of
the east side.
kY / PARKING
%-PARKIN
C7
_Z
Y
cr
Q
a
J
�
Ni0
r
i
m
Z
W
a
W
co
W
J,
Q
N
KENSINGTON DRIVE
SITE PLAN Figure 2
in this study will use these new geometrics. The geometry on
Harmony Road is not proposed to be changed at this time.
The generated trips from Colorado Imports were assigned
to the College/Harmony and College/Kensington intersections.
This assignment used the trip distribution shown in Figure 3.
Figure 4 shows the short range (1995) peak hour traffic at the
two College Avenue intersections. Background traffic was
increased appropriately based upon historic data. Since the
status of development between the McDonald's Restaurant and
Kensington Drive is not known at this time, the assumed uses
for these parcels from the Auto Avenue Site Access Study were
not included in this short range assignment. Based upon the
volumes shown in Figure 4, traffic signals would not be
warranted at the College/Kensington intersection. Therefore,
this intersection would continue with stop sign control.
Table 3 shows the short range peak hour operation at the
two College Avenue intersections. Calculation forms are
provided in Appendix C. With the future geometrics, the noon
peak hour operation will be at level of service D. There will
be no movements worse than level of service D. During the
afternoon peak hour, level of service is not determined for
the entire intersection, since the V/C is greater than 1.2 for
at least one movement. This movement is the eastbound left -
turn on Harmony Road. Many iterations of phasing were rVn
with the one shown in Appendix C as the best. The eastbound
through/right movement and the westbound left -turn movement
are less than level of service D. The operation was improved
to level of service D (28.6 S/V) with the addition of an
eastbound right -turn lane and an additional westbound left -
turn lane. This calculation form is also provided in Appendix
C. Improved geometry on Harmony Road should be considered by
the City in the future. The traffic which precipitates this
recommendation is background traffic. With stop sign control,
left -turn exits from Kensington will operate unacceptably.
This intersection will be signalized in the future according
to the Soutli College Avenue Access—Control—P-1-an.. There —is
nothing that can be done to improve this operation short of
signalization. These movements'do have alternative means of
egress via Mason Street.
In the long range future assignment, it was assumed that
the property between McDonald's Restaurant and Kensington
Drive would be developed. Traffic estimates were made for the
east leg of Kensington Drive without, the benefit of any
detailed trip generation analysis, except the assumptions used
in the Auto Avenue Site Access Study. There are no proposals
for properties that might be served by Kensington east of
College Avenue. A more rigorous analysis for this leg is
beyond the scope of this traffic analysis. Figure 5 shows the
long range (2010) peak hour traffic at the two College Avenue
intersections. It is expected that at or before this future
SHORT RANGE % / LONG RANGE %
TRIP DISTRIBUTION
Figure 3
r
KENSINGTON
HARMONY
SHORT RANGE
FUTURE PEAK
25/25 —r
22/22 `
W
W
J
J
O
0
N
0 O W
N
O Of N
co N't'
r— (D N
458/523
193/161
63
roM
r O
c r
N \
N
N
ei
387/475
351/876
276/494
N (D 0)
rn (D• n
CO N
co U)
� N
HOUR TRAFFIC
NOON / PM
Q
N
Figure 4
Table 3
Short Range Peak Hour Operation
Intersection
College/Harmony (signal)
College/Kensington (stop sign)
EB LT
EB RT
NB LT
Level of Service (Delay)
Noon PM
D (25.3 s/v) "
E E
A A
C D
LOS and delay not meaningful when any v/c is greater than 1.2.
Table 4
Long Range Peak Hour Operation
Level of Service (Delay)
Noon PM
College/Harmony (signal)
D
(29 A
s/v) •
College/Kensington (signal)
C
(16.0
s/v) C (16.5 s/v)
x LOS and delay not meaningful when any v/c is greater than 1.2.
KENSINGTON
HARMONY
LONG RANGE
FUTURE PEAK
to
co
00
0 N 0
� 0 co
00 -�
. �O
N
115/90
NOM.
135/115
W
(7
W
.J
J
0
0
0
0
o co 0
to r O
C.4
� 0
000
O r to
r r M
250/300
500/600
230/200
130/110
NOM.
80/90
to to 0
co r
co
O
^� 0
O 0
0
r
400/500
400/900
300/550
000
000
MN M
� r �
00
It 0 r
N O.N
N
r
HOUR TRAFFIC
NOON / PM
Q
N
Figure 5
year, a signal would be installed at the College/Kensington
intersection.
Table 4 shows the long range peak hour operation at the
two College Avenue intersections. Calculation forms are
provided in Appendix D. The noon peak hour operation will be
at level of service D with only improvements to College Avenue
as described earlier in this memorandum. There will be no
movements worse than level of service D. During the afternoon
peak hour, level of service is not determined for the entire
intersection, since the V/C is greater than 1.2 on a number
movements. Further operation analysis iterations indicated
that acceptable operation could be achieved at the College/
Harmony intersection during the afternoon peak hour only with
geometric improvements to the intersection. These
improvements are: an exclusive right -turn lane on the,west
leg of Harmony Road; double left -turn lanes on the east leg
of Harmony Road; and a combined through/right-turn lane on
both legs of College Avenue. The operation was improved to
level of serviceD (37.1 S/V) for the overall intersection.
The calculation form for this analysis is also provided in
Appendix D. Even though the operation of the intersection is
at level of service D, there are three movements that are at
level of service E operation.The six lane cross section of
College Avenue is the level of improvement indicated in the
North Front Range Corridor Study. With the warranted signal,
the College/Kensington intersection will operate acceptably.
The future geometrics on Kensington Drive should be an
eastbound left -turn lane, a combined eastbound through/right-
turn lane, and a single westbound lane.
Conclusions/Recommendations
It is concluded that the existing Auto Avenue Site Access
Study, February 1988, along with this memorandum, can serve
as the traffic study for this property with the proposed
Colorado Imports automobile dealership. The 1991 improvements
to Corr-ege--Avenue--wihl—improve--the—operation—at—the
College/Harmony intersection in the short range future. The
City of Fort Collins should consider geometric improvements
to Harmony Road at this intersection in the future. With stop
sign control, the left -turn exits from Kensington Drive will
operate unacceptably. This operation will be acceptable when
the intersection is signalized. This proposed use will take
all access from Kensington Drive. The proposed use will have
less impact on the area streets than the formerly proposed
Auto Avenue uses.
Pedersen Toyota Volvo Saab PUD - Preliminary & Final, #26-91
June 24, 1991 P & Z Meeting
Page 3
3. Neighborhood Compatibility
South College Avenue from Prospect to Harmony has been defined as
a community/regional shopping center, therefore, the request for an
auto dealership has been interpreted to be compatible with the
surrounding area. For this reason, no neighborhood meeting was
held.
4. Design:
This proposal for an auto sales dealership consists of a 27,222
square foot building for auto sales, service, and office uses.
Part of the building will be two stories, with no part of the
building to exceed 40 feet in height. The second story will add an
additional 7,585 square feet of office space to the 19,637 square
foot first floor building footprint. The entire perimeter of the
site would be landscaped with a variety of deciduous and evergreen
shrubs and trees.
The exterior building surfaces are proposed to be a white synthetic
stucco with red and dark grey accents. The trash enclosure and
used oil storage enclosure will be constructed of similar
materials. Glazing elements of the showroom on the east and south
elevations will be anodized aluminum storefronts with dark frames
to reduce glare. Construction will include 4-5' overhangs, at
walls with significant glazed surfaces, to shade glazed openings
and reduce solar gain in summer months, thereby reducing cooling
demand. The entire building will be provided with a fire sprinkler
system.
The building is set back 115' from the flow line of Kensington
Drive and 81' from the flow line of College Avenue. There is a 10,
landscaped buffer behind the 4' connected walk on Kensington and a
26' landscaped buffer which includes the 7' detached walk along
College Ave. A combination of shade and ornamental trees, shrubs,
turf and flower beds provide a visual buffer, seasonal screening
and color, and provide an attractive setting for vehicle display
which is a necessity of this proposed use.
The applicant has provided three spaces along College to display
vehicles "sideways". These areas are more heavily landscaped on
both sides of the display area and function in part to break up the
line of car grills as seen from College. A cluster of evergreen
trees and shrubs has been provided at the northeast corner of the
site to provide some screening of the interior of the site from
southbound lanes of College Avenue. The entire north property line
will be planted in a combination of shade trees and evergreen
Pedersen Toyota Volvo Saab PUD - Preliminary & Final, #26-91
June 24, 1991 P & Z Meeting
Page 4
shrubs to provide additional buffering of the car lot from the
north property line. There are existing shade trees along the west
property line on the Mini-U-Storage PUD property. The applicant
proposes a 4' landscaped strip of fescue mix along this property
line.
The applicant is proposing one elevated landscaped area for the
display of one car in the interior of the site. The applicant is
not proposing any car racks at this time. Any racks proposed in
the future would require an administrative change, would not exceed
4' in height and would be restricted to the horizontal plane. No
angled display racks would be allowed on this PUD.
Building signage is proposed to be individual pan channeled letters
which are internally illuminated. No cabinet signage is proposed
on the building. The Pedersen Logo has not yet been designed, but
the lettering and size will be similar to that shown on the
architectural elevations. In any case, lettering on the east
elevation will not exceed the size of the fascia band. Wall
signage on the south elevation above the service area will be no
larger than 18 inches in height and limited to that shown on the
plans.
Two ground mounted internally illuminated monument signs are
proposed. The applicant has provided descriptions of these signs
on the architectural elevations. The base is proposed to match the
stucco of the building. The color of the letters has yet to be
determined but would likely be blue, red, or gray to match the
building accents and trim. The signs would be just over 10' high
and would be placed in landscaped planting areas. Any signage
(other than directional signage) that is not shown on the plans
will not be allowed on this PUD without further review by the
Planning Department and/or Planning and Zoning Board.
Staff has reviewed the lighting plan and initially had concerns
about how much illumination the flood lights would give off. All
lighting on the site will be down directional with sharp cut-off
luminares and no light spillage off the site. The poles for the
light fixtures will be a dark color, they will not be white or
silver. Staff compared the lighting levels for other car
dealerships along the South College Corridor from Drake Road to
Harmony Road and have requested that the applicant provide
documentation that this PUD will have a similar level of light
maintained on the front row as do Markley Motors, Dellenbach
Chevrolet, Ed Carroll Motors, and the new Saturn dealership. The
amount of light at Spradley Barr Ford is not acceptable.
Pedersen Toyota Volvo Saab PUD - Preliminary & Final, #26-91
June 24, 1991 P & Z Meeting
Page 5
The applicant's electrical design engineer, John Benson, stated
that the lighting design for Pedersen Toyota, Volvo, Saab PUD will
result in approximately 15 to 25 foot candles (FC) of illumination
maintained on the front row, tapering off towards the interior of
the site. As a reference, industry standards for foot-candle
illumination of parking lots is between 5 and 10, baseball infields
are 10 to 50 (FC), gas station pump areas are 30 (FC), and
illumination of a dark monument or wall is 50 (FC). According to
the lighting engineer for Tynan's Nissan, the current illumination
on the front row of the Nissan dealership on South College is
approaching 280 FC. Staff feels that an illumination level of 15
to 25 (FC) would be reasonable and justified for this use. Any
increase in lighting levels would require review by the Planning
Department and/or the Planning and Zoning Board.
5. Transportation:
Access to the Pedersen Toyota, Volvo, Saab dealership site will be
off of Kensington Drive. There will be a loop drive around the
building for circulation and emergency access. The two north -south
drives will be signed "Fire Lane -No Parking". Access to the
service center is from the entrance drive directly north to the
entrance on the south side of the building. Serviced vehicles exit
to the north and are parked in the north lot or are brought around
the building to the south lot.
Sixteen customer parking spaces are provided close to the building.
One handicapped space is available close to the entrance, 45
employee parking spaces are provided to the rear of the building
near the service exit area, and 118 display spaces are provided
along the perimeter and at the north side of the site.
There is no direct vehicular access to South College Avenue from
this site. This design is in conformance with the South College
Access Plan which was adopted in 1988. A detailed traffic study
for the Auto Avenue Mall PUD was submitted and reviewed by the
Transportation staff in February of 1988 and an amended traffic
study was submitted with this request. The Transportation Staff
has reviewed the amended traffic study and accepts the conclusion
that this request will be less intense than the previously approved
retail, convenience store, and auto related uses.
In the short term analysis, the intersection of College and
Kensington is indicated for stop sign control. Left turns for
eastbound traffic would be difficult. Left turns for northbound
traffic would operate acceptably. These movements would have
alternative means of egress via Mason Street. The long range
Pedersen Toyota Volvo Saab PUD - Preliminary & Final, #26-91
June 24, 1991 P & Z Meeting
Page 6
analysis, which considers the build out of the Gateway at Harmony
Road PUD and development of East Kensington across College,
indicates that a traffic signal will be required for the
Kensington -College intersection in the future. This is in
accordance with the South College Access Plan. The City's
Transportation Staff has accepted the conclusions of the submitted
traffic study.
6. Storm Drainage
The City Storm Water Utility has reviewed the revised Storm
Drainage Report and Plans for this project and finds that they
adequately address their concerns for erosion control measures,
storm drainage, water quality, and on -site detention requirements.
RECOMMENDATION:
This proposal for a Preliminary and Final PUD for the Pedersen
Toyota, Volvo, Saab auto dealership meets the criteria of the
Auto -Related and Roadside Commercial Uses Point Chart and the
applicable criteria of the All Development Criteria of the Land
Development Guidance System. Therefore, staff recommends approval
of Pedersen Toyota Volvo Saab PUD Preliminary and Final PUD- #26-
91.
No Text
No Text
PEDERSEN TOYOTA VOLVO SAAB P.U.D.
College Avenue & Kensington Drive
Fort Collins, Colorado
submittal date: May 5, 1989
revised
Statement of Planning Objectives
The existing Toyota/Volvo/Saab Dealerships have outgrown
their current facilities on North College Avenue and need to
improve their ability to service clientele. To better
service it's clientele a new location and facilities are
required..
The primary objective is to create new, efficient,
convenient and attractive facilities to enable Pedersen
Toyota Volvo Saab (currently doing business as 'Colorado
Import Motors) to enhance its established operation.
City Land Use Policies Achieved:
Policy 3a: The property has existing development on the
north and west boundaries, College Avenue is to the east and
an approved P.U.D. to the south. This should qualify this
project as an infil project, thereby assisting to satisfy th
City'.s policy of maximizing the utilization of land within
the City.
Policy 21: Primary access for the project is from Kensington
Drive. There is a south bound right turn deceleration lane
from College Avenue onto Kensington Drive.The auto related
land use and Kensington Drive access for this site is
consistent with the City's South College Corridor Plan and
Land Use Policies Plan.
Policy 22: Contiguous development surrounding this proposed
project include a Target store to the north, a mini storage
complex to the west, College Avenue and Kensington Drive to
the east and south respectively. The property to the south
(across Kensington Drive) is an approved P.U.D.. This
project should receive preferential consideration.