Loading...
HomeMy WebLinkAbout725 MARTINEZ STREET PUD PRELIMINARY AND FINAL - 29 91 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSITEM NO. 4 MEETING DATE 7/22/91 STAFF Ted Shepard PLANNING AND ZONING BOARD STAFF REPORT PROJECT: 725 Martinez Street P.U.D., Preliminary and Final, #29-91 APPLICANT: The Resource Assistance Center for Non -profits, Inc. c/o Louise Stitzel P.O. Box 1104 Fort Collins, CO. 80522 OWNER: Louis and Gertrude Ogden 539 Apple Blossom Lane Fort Collins, CO. 80526 PROJECT DESCRIPTION: Request to convert an existing single family home into a duplex. The home is 725 Martinez Street in the Alta Vista subdivision, located north of Vine Drive and west of Lemay Avenue. The zoning is R-L, Low Density Residential. RECOMMENDATION: Approval EXECUTIVE SUMMARY: The R-L, Low Density Residential zone district is for low density residential areas located throughout the City. This zone does not allow duplex units as a use by right. As a planned unit development, the request was evaluated by the criteria of the Residential Uses Density Chart and the All Development Criteria of the Land Development Guidance System. The request scores 100% and thus allows the increased density. The existing home will not be enlarged or modified except to add a separate entry. The proposed duplex will not impact surrounding properties and is considered compatible with the Alta Vista neighborhood. The conversion to duplex is minor in character with little difference in degree over existing conditions. DEVELOPMENT SERVICES 300 LaPorte Ave. P.O. Boa 580 Fort Collins. CO 80522-0580 (303) 221-6750 PLANNING DEPARTMENT 725 Martinez Street P.U.D., Preliminary and Final, #29-91 July 22, 1991 P & Z Meeting Page 2 COMMENTS 1. Background• The surrounding zoning and land uses are as follows: N: R-L; Single family homes S: T; Vacant, Dry Creek E: R-L; Single family homes W: R-L-P; Vacant 725 Martinez Street is Lot 19 of the Alta Vista Subdivision which was platted by the Great Western Sugar Company and approved in 1927. The subdivision was platted, along with Andersonville and Buckingham Place, to provide housing for workers at the Great Western Sugar Factory. 2. Land Use: The request to convert a single family home to a duplex was evaluated by the criteria of the Residential Uses Density Chart and the All Development Criteria of the Land Development Guidance System. The score of 100% allows a density of 10 units per acre and above. The proposed duplex benefits from its proximity to an existing transit stop, a neighborhood park, a major employment center, north Fort Collins, and existing urban development. 725 Martinez Street is part of a 41 lot subdivision that is located on approximately eight acres for an overall density of five dwelling units per acre. The score of 100% would allow this underlying density to be increased. The lot size is 6,250 square feet. The addition of one extra unit within the Alta Vista subdivision is found to be minor in character and does not impact the surrounding property. 3. Design• The existing structure at 725 Martinez will be converted from a single family dwelling to a duplex by upgrading the garden level to a residential dwelling unit. There will be two separate entries. The garden level will be a two bedroom unit totalling 864 square feet. The upper unit will have two floors totalling 1,548 square feet. Both units exceed the minimum requirement of 800 square feet for a legal dwelling unit. A gravel parking area in front of the house can accommodate up to five cars. 725 Martinez Street P.U.D., Preliminary and Final, #29-91 July 22, 1991 P & Z Meeting Page 3 Other than the creation of separate entries, there will be no exterior changes to the structure or landscaped area. 4. Neighborhood Compatibility: The house was built in 1983. planned for the structure, n proposed duplex is considered of the house. Also, the subdivision and there are n There are no significant impa with the request. 5. Transportation: With no exterior changes or additions o neighborhood meeting was held. The appropriate given the size and scale house sits on the corner of the o neighbors on the west or south. cts on surrounding property associated The proposed duplex will not impact the existing street system. It is estimated that one dwelling unit will generate 10 vehicular trips per 24-hour period. This increase can be easily accommodated by the existing neighborhood streets. RECOMMENDATION: Staff finds that the request to convert a single family home into a duplex satisfies the criteria of the Residential Uses Density Chart and the All Development Criteria of the Land Development Guidance System. In addition, the conversion will not include any major modifications or additions to the existing structure thus preserving neighborhood compatibility. Staff, therefore, recommends approval of 725 Martinez Street Preliminary and Final P.U.D. RLP u Z Z I I VINE DRIVE �rlam BL J ■ ■MMNo M . . I p ; ITEM: 725 MARTINEZ STREET PUD NUMBER: 29-91 LANDSCAPING PLAN r ffR:If„ (AS IS) W ti N N^ WM' A«A K � �. . cii km. ✓ehl"lpr,,N, (J l�jea d.X. T. R.y wYel. LNm� IY ALTA'VISTA JV5DIVISONPLAT N6 Lmr oR W;oA w F 5'o a Aj N. l• a •••.•�• MAIN STKU A..^..T I f n of to so Ema: a Xa _ s of loa eof : ea Eoa W J O2•�!Oa 6m a.ma .A a oEi me 1. of Eoa uA.NT � l wa i = fltc I b Z � -- -- ---- I. 7 2 5 M A R T I N E Z S T R E E T PUD SITE PLAN PLANNING AND ZONING CERTIFICATION AONt > aY M ft c NA 3PM0 MWAOO. MM MS 6 rp f Cvtrwi _. O \R scurctO. a .frwlc F Z.0 ROOM OWNER CERTIFICATION M V6fRavllED. ttNG M 4sYI MITE FtBY MRdY MAT MR an AC T M XUFBT M Il MAt M1 MI r M CMdTMf AXp RfR1RICIWA Yi fMM M LO 9R VIIX. [1C'fRa11.0-- a.r wr r al..r. iN r.0 wr. Y.r� f-.wY YN\ f WN.. 1 tliY F« N \.11. CN. _.m _.w r M AN Y1N WrIWn f►� [M« .. N.l\ Xe Ouecnw ' �.m y,rrmw N.Xlr.rruw r � ..�•w Yr a _r...�+. ..Y Y � �.y.• AYYw...�WNIN N R1. Y MIYN INN W-NN. \.� ftltY. h_IYiA. VICINITY MAP 725 AAA RT I N E Z S T R E E T PUD SITE PLAN -7.9 s M fl RT/ /v E z sT REE'• P. V . D.. P - - F ALL DEVELOPMENT: NUMBERED CRITERIA CHART ALL CRITERIA APPLICABLE CRITERIA ONLY CRITERION u the criterion aodicoote? Will the criterion be satisfied? If no, please explain �F.�'� yes No NEIGHBORHOOD COMPATABILITY 1. Social Comoatability 2. Neighborhood Character 3. Land Use Conflicts 4. Adverse Traffic Impact PLANS AND POLICIES 5. Comprehensive Plan PUBLIC FACILITIES & SAFETY 6. Street Capacity Ll 7. Utility Capacity 8, Design Standards 9. Emergency Access / 10. Security Lighting 11. Water Hazards RESOURCE PROTECTION 12. Soils & Slooe Hazard 13. Significant Vegetation 14. Wildlife Habitat 15. Historical Landmark 16. Mineral Deposit 17. Eco-Sensitive Areas 18. Agricultural Lands ENVIRONMENTAL STANDARDS 19. Air Quality 20. Water Quality go,/ ✓ 21. Noise 22. Glare & Heat . 23. Vibrations 24. Exterior Lighting ✓ 25. Sewages & Wastes SITE DESIGN 26. Communrty Organization 27. Site Organization 28. Natural Features boe 29. Energy Conservation 30. Shadows ✓ 31. Solar Access 32. Privacy ✓ 33. Open Space Arrangement 34. Building Height 35. Vehicular Movement 36. Vehicular Design 37. Parking 38. Active Recreational Areas 39. Private Outdoor Areas W, ✓ 40. Pedestrian Convenience 41. Pedestrian Conflicts ✓ 42. Landscaping/Open Areas 43. Landscaping/Buildings 44. Landscacing/Screening A/ 45. Public Access 46. Signs -17- DENSITY CHART 7a6 MAXTIAIEZ Maximum Earned . Criterion Credit If All Dwelling Units Are Within: Credit a 20% 2000 restotm ex-nnp«ap«aea nepnbanooa snowing center. b 10% e50reeroron exanrp nansrnrop. /D ' C 10% 4000reet OfMexiinrgaraoorcvW e(n« V=onpcwtw, d 20% 3500restoton emoting «rasneon gricom000 pork communM oar«C«nmunM tocnM. �O We 10% to00teetorafchoa,mesnngon", t fwnwrsormecomw oau atg wormesrmeorcacraw f 20% 3000 restot a mopremooYrrrnrcentw. C20 5% 1000reeroracnnacarecenter, h 20% 'North'ForrCplIft ao I 20% iheCenrrd8nines.0omct. AIXOPOwrW se bout W ary - cahpgr- ro a-leq urban oevegarorst. Credo may be eomea m towws 0%—ForpoiecbWn womrWbounaavr Oro/0%conOW. .. j r 30 /o 10f015%—Foraolscrfwhafeorooertvooun=vrxa10to20%confptrrv.. t5to20%—Fa Cwgre n»ear«ooembaunaary 2Oto70%co VAf. 20ropr 25%—F«owMwl oropertvb«r+Carvnm30toe0%co Vjr; 30 25 ro 30%—Far prooclf whmpropsrN boundary nm 40 to 50%ca+npuity, k h rtca+be aen+onmaea mdme prolectwfnrewce non.erowpdserwrgy ufsaps anar mrouryt ms opd�oonon d arernane erwpr noofr ems«mroupncommmep e,uils. fen afan ennua bs aw hdnamaNreau ea by MCoasaS% owa may reamed r eyery 5%reaucnort inw{)y ws. er I. Calculate a l%bcnw for every 50 acrel nOUOsam the aoplict. m CalarWre mepaGntaQedmerord rasantne oropamaars asANarore«eallat«wRenlw V2ormdoercenlowwabonln n hme commmro«as t permarwtronvleroanfoots marmesume CiNa mnlnrrrn rearrerrtanKcdutrlols me percennpps apolnl U) dmeooen space aasaperome lard wv«oonwxocreopwanrerma oacenrapsmaoorna O If banal the rota ae elopnMnrbuapet u10 bs SWIM ralghbornooa ou0 C trorwtt0Q11hMvm Cn are raromerww requrea by CM Code. entW2%bonutt«every51000wawelNnp Wt,meoe6 p Ir pan of the land ae+elOpRM o Cwat ero bass "nerQMOrt100d faalmss arW fawcef wftich ae n0lomawgs reaffrea oY CMCoae. aalvquMnwyeste6 attest%banwror eervst00pa pw Ira Canmrnenl-beetprtfaderoasveaDaSpeallea percentapsdmerota numbadawaeirlpunr-fcraw ncanefanYiey anima G percentage m a bofraup to a ma-+rrn d30% Z 0oconrrMnom3bengntodeto aswtooa spnle ecd pwcenroge derv, d tam number Vvb for at Type WOW Type hdlcappect ha-tngm aeMeaby me CM of Fort Cathntcalculate etebon -all lallewt O f iype'A'— .S hrna oT�x — _ ^/'� Co — LypeH—t.Orref Type -runt In no can fill the camb+rd bar- be greater coon 3M emeSrl-orodxcie,Oapsrtycarl0o atfte" bulmtg«oi=aoborr-maybsearleatm"tolowrg 3% — Faprevenergpmlbga-rtgafibenAwWes(saalwatmertra lanams.asserhe sconbneeandsoaalrocfanl oWaraas S PMSONOHM 3% — For mYlrgmatrwfmtwfwwA be in Yssongwllh InecMocieroflhebwh*ga po= whesavaarq told unef 3% — For pr000vgadapfNMt-edmebulbg«pfoceMatw- Mad rommminuancs.prerrvotlonandwroror«rwxnm aoaaalplemorew. -a pdrllaf ad1 dlhereWeedpagngln t w rtuepleran*vproMO isp"MdWuWapourW,wlnn ms bWmtp «nanekvaea panmp fms-remanabteabryusblMplmay-n,cnae.oborxn maybe eaneam toff w t 9% — Forpiaiiia 75%crrmed1hsporkh nafmrctrs: a% — F«provice 50-74%diner o nnofmcturs 3% — Faprwas1ng 25-O%dlM palenginasnuasrs. U eacmwrrenentebengrttoaebaoygeaoproyedouRxtWnenroaartguerwgsytaroformsaweeMtgurvRenMabanufd+o% ..TOTAL /o 0 —30—