Loading...
HomeMy WebLinkAboutSPLIT RAIL MINOR SUBDIVISION - 37 91 - CORRESPONDENCE - CORRESPONDENCE-CONCEPTUAL REVIEWDevelopn t Ser✓ices Planning Department City of Fort Collins July 3, 1991 Paul Boone 1809 Greenbriar Drive Fort Collins, CO 80524 Dear Mr. Boone: For your information, attached is a copy of the Staff's comments concerning 1809 N. College Avenue Elderly Board and Care Home, which was presented before the Conceptual Review Team on July 1, 1991. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. Sincerely, �ls lj li� Kirsten Whetstone Project Planner KW/gjt Attachment cc: Tom Peterson, Planning Director Kerrie Ashbeck, Civil Engineer Project Planner File 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-0750 CONCEPTUAL REVIEW STAFF %'OMMENTS MEETING DATE: July 11 1991 ITEM: 1809 N. College Avenue Elderly Board and Care Home APPLICANT: Paul Boone 1809 Greenbriar Drive Fort.Collins, CO 80524 LAND USE DATA: This is a proposal to convert an existing motel, the Lamplighter Motel at 1809 N. College Avenue, to a board and care home for elderly. There are approximately 40 motel units, an office area, a pool and a large suite on the property. There are no plans to increase•the roof area or parking lot. The existing carport area may be closed off to provide a central kitchen and dining area for the board and care home. The applicant wodld also be living on the property' and may have to create a living unit with a kitchen, if one does not currently exist. COMMENTS: 1. The property is located in the HB, Highway Business, zone which allows group homes as a use by right. Because the lot has"not been platted, this proposal -would require a plat, which could be processed through the Minor Subdivision process. The applicant has already obtained the necessary variance from the ZBA to increase the number of residents over what is allowed in the zone. 2. Along with a plat of the property, we would ask you to submit a site/landscape plan at a scale of. 1"=30' to 1"=40' to show the layout of buildings, parking, landscaped areas, curb cuts,.._ storm drainage flows, signs, light posts, fire hydrants, automatic fire sprinkler connection location, and other exiting or. proposed- paved areas. 3. If you will be increasing the electrical load from that of the existing use, there will be development charges from.Light and Power.If the electrical panel size which serves.the site. is"....... sufficient, then there will not be additional charges. You:_., . will need to fill out a C-1 form to determine your anticipated loads. If the transformer needs to be relocated or changed, it will be done at your expense. 4. Light and Power will need easements to be shown on the plat for the existing overhead lines which run across this property to the north boundary. 5. The existing water service is a 1 and 1/2" service. If this is sufficient for your needs, there will be no additional hook up fees. You will have to investigate the fire flows in the main to see if they are adequate. There may be some problems with the 4" water main on the west side of College Ave. which may require you to hook up to the 6" on the east side of College and, abandoned the service tap on the 4". *You may already be hooked up to the 6" line, in which case, fire flows should be adequate. 6. There is a sanitary sewer system traversing the rear of the property. This system should be shown on the plat in a 30' utility easement (15' to either side of the centerline of the sewer line). Any other existing or proposed utility, drainage, or access easements should also be shown on the plat. 7. The nature of the proposed use requires that the building be equipped with a fire sprinkler system and a fire alarm system. The Fire Authority -can assist you in determining fire flows of the water service to see if they are adequate to meet your needs.- Fire access looks acceptable, given that there would be a sprinkler system for the units. 8. If any residential units (units with cooking facilities) are added to the site, there is a parkland fee of $625.00 per unit paid at the time of building permit issuance. This would not apply to a remodel of an existing residential unit, or to the addition of a commercial kitchen, dining area. 9. Storm Drainage fees are $4 "3.00 per acre for any increase greater than 350 sq. ft. in the imperviousness of the site. You will need to submit a drainage report and plans to show how drainage flows will change with this new use. If the carport is enclosed and drainage is prevented from going through the open area, where will it go instead? Glen Schlueter at the Storm Drainage department will be able to assist you in preparing the plans. It may just be a matter of drawing some arrows on the site plan and comparing the drainage flows of the proposed project with the existing situation. 10. The project is located in the Dry Creek Floodplain and any federal financing will require flood insurance. 11. A grease trap will be required if a commercial kitchen is installed. 12. There .are several different building occupancies on the property depending on mobility of the residents and whether they are on the first or second floor. You will need to work closely with the Building Inspection Department in making any changes to the existing building in order to meet the building code for the various occupancies. 13. The Transportation department has requested a traffic analysis to document how traffic patterns at this site will change as a result of the change in use. The analysis should also document how closing off the carport area will change the distribution of trips coming and going from the two curb cuts. Will all of .the .new trips use the south entrance, or will the north entrance still be used? If you have questions about this, please contact Eric Bracke at 221-6608. n