Loading...
HomeMy WebLinkAboutBLEVINS SUBDIVISION LOT 9 PUD FINAL - 42 91B - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSITEM NO. 2 MEETINGDATE 4/27/92 STAFF Kirsten Whetstone City of Fort Collins PLANNING AND ZONING BOARD STAFF REPORT PROJECT: Blevins Subdivision Lot 9 PUD Final- #42-91B APPLICANT: Robert K. Glover 2101 Lindenmeier Rd. Fort Collins, CO 80524 OWNER: Same as Applicant PROJECT DESCRIPTION: This is a request for a final PUD for a duplex on Lot 9 of the Blevins Subdivision. The lot is 11,846 square feet in size, is currently vacant, and is located on Blevins Court, north of Prospect Road and west of Whitcomb Street. The property is zoned RL, Low Density Residential. RECOMMENDATION: Approval EXECUTIVE SUMMARY: The applicant proposes a one story duplex with a basement level, on a vacant lot in Blevins Subdivision, an established residential neighborhood which primarily serves college students and CSU employees because of its close proximity to the Colorado State University campus. The proposal is in substantial compliance with the approved preliminary PUD plans. Conditions of preliminary approval concerning landscaping, parking and drainage have been met. DEVELOPMENT SERVICES 300 LaPorte Ave. P.O. Bo: 580 Fort Collins. CO 80522-0580 (303) 221-6750 PLANNING DEPARTMENT �Ctr'lll.'�r3 1,L1 T 9 Rj D -- ZinJA ALL DEVELOPMENT: NUMBERED CRITERIA CHART �`-� 9'd ALL CRITERIA APPLICABLE CRITERIA ONLY CRITERION Is the criterion ocohcoble, Wdl the criterion oe satisheoi If no, please explain ,e'F�' ,��a Yes No NEIGHBORHOOD COMPATABILITY 1. Social Compatability ✓ l/ 2. Neighborhood Character v 3. Land Use Conflicts v ✓ 4. Adverse Traffic Impact v PLANS AND POLICIES 5. Comprehensive Plan ✓ V PUBLIC FACILITIES & SAFETY 6. Street Capacity ✓ ✓ 7. Utility Capacity ✓ V 8. Design Standards V ✓ 9. Emergency Access +/ V 10. Security Lighting ✓ 11. Water Hazards ✓ RESOURCE PROTECTION 12. Soils & Slope Hazard 13. Significant Vegetation ✓ 14. Wildlife Habitat ✓ 15. Historical Landmark 16. Mineral Deposit ✓ 17. Eco-Sensitive Areas v 18. Agricultural Lands ENVIRONMENTAL STANDARDS 19. Air Quality ✓ 20. Water Quality ✓ 21. Noise ✓ �/ 22. G7are & Heat ✓ 23. Vibrations ✓ 24. Exterior Lighting ✓ 25. Sewages & Wastes ✓ SITE DESIGN 26. Community Organization ✓ ✓ 27. Site Organization ✓ ✓ 28. Natural Features ✓ �/ 29. Energy Conservation / ✓ 30. Shadows 31. Solar Access 32. Privacy ✓ 33. Oden Space Arrangement 34, Building Height ✓ 35. Vehicular Movement ✓ 36. Vehicular Design ✓ ✓ 37. Parking ✓ 38. Active Recreational Areas 39. Private Outdoor Areas ✓ `� 40. Pedestrian Convenience 41. Pedestrian Conflicts ✓ 42. LandsccoingiCoen Areas ✓ 43. LandscapingrBwldings V 44, LandscapingrScreening ✓ ✓ 45. Puouc Access V 46. Sions ✓ -12- rs Blevins Ct. Collins, Co 1 21, 1992 Kirsten Re: Blevins Court PUD, Lot 9 - Final, #42-91B I am writing in response to your letter of April 14, 1992, regarding the P & Z Board meeting scheduled April 27, 1992. As an immediate neighbor of this development I wish to inform you of my opinion, as I will be unable to attend the meeting. I had no misgivings when the proposal was for a triplex. Frankly I was surprised at the negative neighborhood reaction. I feel the best use of this neighborhood would be high density residential. The building of a duplex would constitute the minimum good use of this lot. Thank you for time and interest. Sincerel "'i, �J,,, Melanie ,J Peters DVM cc: Planning and Zoning Board Blevins Subdivision, Lot 9, PUD Final- #42-91B April 27, 1992 P&Z Meeting Page 2 COMMENTS: 1. Background The surrounding zoning and land uses are as follows: N: R-L; CSU and single family homes (Blevins Sub) S: R-L; single family homes (Blevins Sub), duplexes, in -home bike shop E: R-L; single family homes (Blevins Sub) and CSU married student apartments W: R-L; single family homes (unplatted), church meeting hall, student fraternity and sorority houses. This property is Lot 9 of the 22 lot Blevins Subdivision which was subdivided in the County in March of 1955 and annexed into the City in December of 1956. The property was zoned RL-Low Density Residential, at the time it was annexed into the City. Lot 9 is the last vacant lot in this subdivision. The preliminary PUD was approved by the Planning and Zoning Board in February of 1992, with conditions regarding landscaping, parking and drainage. 2. Land Use The proposed use consists of a one story duplex building, with a basement level, on an 11,846 square foot lot. The two units would each have three bedrooms. Six parking spaces are provided, as are bike racks and motorcycle parking. The property is currently zoned R-L, Low Density Residential. The current owner/applicant would maintain ownership of the units and would act as the property manager. The owner would be responsible for all lease agreements and maintenance of the building and grounds. The proposal is in substantial compliance with the approved preliminary PUD plans. 3. Desicrn The proposed duplex is set at an angle on a pie shaped lot. From the street, the corner of the side and back wall will be visible, but the angle will be such that neither wall directly faces the street. The building is proposed to face east. The orientation of the building on the lot provides for a maximum backyard area. Back doors and privacy patios to access the back yard are proposed. The parking area, building, and fence are set back from the street 35, to 40' to maintain continuity of front yards on Blevins Ct. The duplex meets the setback requirements of the RL zone. The existing trees will remain or will be relocated. The applicant is proposing to plant an additional 10 deciduous and evergreen Blevins Subdivision, Lot 9, PUD Final- #42-91B April 27, 1992 P&Z Meeting Page 3 trees, in varying sizes, throughout the lot. Additional shrubbery and upright coniferous landscaped beds will soften the privacy fence and provide additional noise buffering for the parking area. Building foundation plantings are proposed to soften the building elevation on the east and north sides. A condition of preliminary approval, that a final, detailed landscape plan be submitted prior to final approval, has been met. The final landscape plan shows foundation plantings, details about which trees would be relocated, additional plantings to act as a buffer between the parking area and the privacy fence, and the location and description of the additional trees. Approximately 62% of the site is landscaped with lawn, trees, or shrubs. The building is proposed to be 1 story high with a low sloped roof, materials, colors, and relative scale to lot size, similar to existing houses on Blevins Ct., in order to aesthetically blend the proposed structure into the neighborhood. The trash receptacle will be enclosed and landscaped. 4. Neighborhood Compatibility Three neighborhood meetings were held for this project. Major concerns were density, parking, and general site design. As a result of neighborhood, Staff, and Planning and Zoning Board input, the applicant reduced the number of units from 4 to 2. Staff feels that a duplex is compatible in bulk, scale, and density with the surrounding neighborhood. Land uses of the surrounding area, include single family houses; married student housing complexes; college classrooms, labs, and offices; a Baptist Student Union meeting house; duplexes; a church, church -school and daycare; an in -home bike shop; and fraternity houses. 5. Transportation The property is located on a short cul-de-sac off of South Whitcomb Street, mid -block between Prospect Road and Lake Street. Whitcomb Street is a major connection to the CSU campus from Prospect Road, particularly now that the connection between Pitkin and Lake Streets exists. Transportation does not have concerns from a traffic standpoint, as trips generated by 2 additional units at this location will be insignificant compared to the existing volumes. The Planning and Zoning Board requested a condition that at least 6 parking spaces be provided. The applicant has provided 6 parking spaces as well as bicycle and motorcycle parking. 6. Storm Drainage The Stormwater Utility requested that a condition be placed on approval of this project that the final drainage report and Blevins Subdivision, Lot 9, PUD Final- #42-91B April 27, 1992 P&Z Meeting Page 4 drainage and grading plans, including an erosion control plan, be approved by the Stormwater Utility prior to final approval. This condition has been met. RECOMMENDATION Staff finds that the proposal is in substantial conformance with the approved preliminary plan. The three conditions of preliminary approval have been met. Therefore, staff recommends approval of Blevins Subdivision Lot 9 PUD Final- #42-91B. DeveloF nt Services Planning Department City of Fort Collins MEMORANDUM TO: Planning and Zoning Board FROM: Kirsten Whetstone, Project Planner DATE: April 24, 1992 RE: Revisions to Items on the April 27, 1992 Planning and Zoning Board Hearing Agenda. Please note the following additions or changes to the following Staff reports: 1. For Items #2 and #6 on the Agenda, (Blevins Court PUD #42-91B and Oakridge PUD loth Filing #13-82AZ), please add the following condition to the recommendations for approval: That the Development Agreement for the planned unit development be negotiated between the developer and City staff and executed by the developer, and that the utility plans be fully executed and approved by the City prior to the next monthly meeting of the Planning and Zoning Board; or, if not so executed, that the developer, at said next monthly meeting, apply to the Board for an extension of time. If the staff and the developer disagree over the provisions to be included in the Development Agreement and/or utility plans, the developer may present such dispute to the Board for resolution if such presentation is made at the next succeeding monthly meeting of the Board. The Board may table any such decision, until both the staff and the developer have had reasonable time to present sufficient information to the Board to enable it to make its decision. (If the Board elects to table the decision, it shall also extend the term of this condition until the date such decision is made.) If this condition is not met within the time established herein (or as extended, if applicable), then the final approval of this planned unit development shall become null and void and of no effect. The date of final approval for this planned unit development shall be deemed to be the date that the condition is met, for purposes of determining the vesting of rights. This condition has been added to the staff reports in the project files, as the Utility Plans and/or Development Agreements for these projects have not yet been signed. 281 North College Avenue • P.O. Box ;80 - Fort Collins, CO 80522-0380 • (303) 221-o �;0 2. On Item #8, Kingston Woods PIID #58-91A, the applicant has agreed to put a note on the plans to allow a 4' high fence, of open construction, either a shadow box or split rail design, along the north edge of the detention pond in the northeast corner of the property. The applicant has agreed to specifically exclude a 6' high solid wood fence in this location. 3. On Item #10, Fort Collins Second and Harmony at the villages at Harmony West PIID # 3-90F, the applicant has agreed to put a note on the site and landscape plans to restrict the 42" high, steel, chain link fence to the parking lot area (along the north and east property lines only) where the fence can be well landscaped. A 42" high, dark colored, vinyl clad (coated wire) fence will be provided in the front lawn area (along the irrigation canal) south of the parking lot at the southeast corner of the property. No Text YJ L PVINS 5Il8D I\ e�vu .ar. rrvsa � / / � •�G•L rr.MI.,Y s10N, Lei 9 P. 0. LM I ,rlLau wr.w.a � Lrwu 7M. ilir /�ilwr� .w Allll� i. i n H n -Paoeve�r vim• � . a� ✓r Is I 1 �II 'W4Y•. JT I, � g I1I C[Icv. N/uY _ Wwe NO PYYA.i�iiw. ( � it Jc _Jr✓ M •f .;.nt w.r +� ur ie/ LJr i� ._— ftxNT�N4 uNaow.i awra: wnr..r n.ii, )u� W Ilyyrp^"^.�.wnv"'.nI,F.•q't �`srai i ti0 e�R iJ ALLr w b e ;-7 ! MY 9 ^m'7.°r�u'.�'�}Na� rw wa K rca./ Jug �H Y! :a x 9 9 o� e _ ,Ka4eGT D.xT�a nn IIJ f A6 slit. �, /.K _ �_ [Z� 1,Ny! ppewnt Y4�i �} vwsnv. lAl uwlyh nWa N[M= 3,OA4 if. n:/IIL/LOi Oil/ I/1.JL LNGV.fE • tuaN4 = .,su u IS.sX swuSAi¢• I W a.. A ♦Ylala4: IlllS to '6hv vu ileLµ QJ.µ O O TJnY.: II/Ku I/IJX fIWUV4: Mteaa (IL.I'fl 8i,M1oQm (1al'' a A1Nci Ll.pvlll 1 +wravcv Urt� x llcYc:f (3•Mwl» G MaY. IXD6. Na19Nr+ 2i ZeLLlwq: IL LWo usC: Ql+Oe.ReL � i LEaAa L1reGurTYµe Si MIY�IIyM� �i`+�wQ ' � �6yy,WIY�fM e uuwk Z t _ tiN.N�N4 d ZA.�Iw4 LlCIRIU�TI/N aY a LL 3 � /n T•r� TM In •eR TM� J :, culnM s'rNn naaa"W bvµw9 W OwNEwS cealinlGTiM r Gu e�i�i"w :ni X,"i/aN[Y� Cal; inIGT/N i»Ir :nm csan.Y +rar •N l•e an Ir�.rre.•}en:m �i:tZe�C}I� .p wMY +CteN AF Is W e \\` f ♦Caelef a C� •CAWIN N/. �. a 7 a 6 � t�i II i a • etj • �e v h t I/ N — /W. W -- �_