HomeMy WebLinkAboutKECHTER TOWNHOMES - PDP200010 - SUBMITTAL DOCUMENTS - ROUND 1 - ARCHITECTURAL DETAILSUP UP UP UP
UP UP UP UP
4 5 7 9
A
D
12 13
B
E
6 8
C
1 2 3
10'-9 1/4"
3'-7 3/4"
10'-7 3/8" 10'-1 1/4"
3'-11 1/4"
10'-6 3/8" 10'-0 1/4"
3'-11 1/4"
10'-6 3/4" 10'-1 7/8"
3'-11 1/4"
10'-5 3/4"
98'-8 3/8"
39'-5 1/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
UNIT 1
781 GSF
UNIT 2
761 GSF
UNIT 3
768 GSF
UNIT 4
781 GSF
A1.2
1
4 A1.2
A1.2
3
A1.2 2
10 11
ROOF SHOWN
DASHED
RECESSED LIGHT
FIXTURE (E1) ABOVE,
RE: SHEET A1.5
RECESSED LIGHT
FIXTURE (E1) ABOVE,
RE: SHEET A1.5
4 5 7 9
A
D
12 13
B
E
6 8
C
1 2 3
10'-9 1/4"
3'-7 3/4"
10'-7 3/8" 10'-1 1/4"
3'-11 1/4"
10'-6 3/8" 10'-0 1/4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
4 5 7 9
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
6 8 12 13
98' - 6"
GARAGE
132' - 5"
TO ROOF
1 2 3
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
10 11
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
9 7 5 4
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
13 12 8 6
98' - 6"
GARAGE
132' - 5"
TO ROOF
3 2 1
32'-5"
10'-7 1/8"
1'-0 5/8"
9'-1 1/8" 13'-2 1/8"
11 10
A/C CONDENSER
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
4 5 7 9
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
6 8 12 13
98' - 6"
GARAGE
132' - 5"
TO ROOF
1 2 3
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
10 11
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
9 7 5 4
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
13 12 8 6
98' - 6"
GARAGE
132' - 5"
TO ROOF
3 2 1
32'-5"
10'-7 1/8"
1'-0 5/8"
9'-1 1/8" 13'-2 1/8"
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 2:42:34 PM
A1.4
3D VIEWS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING B
(BUILDING F SIMILAR)
WS
CR
4 3D VIEW OF FRONT
2 3D VIEW OF FRONT
SELF ADHERED FLEXIBLE FLASHING
MARRIED 8" UP JAMB
3 1/2"
VINYL WINDOW
WEATHER RESISTIVE BARRIER
FIBER CEMENT LAP SIDING
SEALANT
X
FIBER CEMENT TRIM SYSTEM
VINYL WINDOW
SEALANT
FIBER CEMENT TRIM SYSTEM
SELF ADHERED FLEXIBLE FLASHING
SEALANT
WEATHER RESISTIVE BARRIER
SEALANT
FIBER CEMENT LAP SIDING
3 1/2"
X
1/4"
1/4"
5 1/2"
1/4"
VINYL WINDOW
SEALANT
WEATHER RESISTIVE BARRIER
SEALANT
FLASHING
SELF ADHERED FLEXIBLE FLASHING
WEATHER RESISTIVE BARRIER
FIBER CEMENT TRIM SYSTEM
FIBER CEMENT LAP SIDING
X
MARRIED 8" UP JAMB
VINYL WINDOW
SELF ADHERED FLEXIBLE FLASHING
WEATHER RESISTIVE BARRIER
FIBER CEMENT PANEL SIDING
X
FIBER CEMENT TRIM SYSTEM
3 1/2"
VINYL WINDOW
SEALANT
SELF ADHERED FLEXIBLE FLASHING
SEALANT
WEATHER RESISTIVE BARRIER
SEALANT
FIBER CEMENT PANEL SIDING
X
FIBER CEMENT TRIM SYSTEM
3 1/2"
VINYL WINDOW
SEALANT
WEATHER RESISTIVE BARRIER
SEALANT
FLASHING
SELF ADHERED FLEXIBLE FLASHING
WEATHER RESISTIVE BARRIER
FIBER CEMENT PANEL SIDING
X
UP UP UP
1 2 4 6 7
A
D
8 9 10
B
E
3 5
C
11 12 13 14
10'-9 1/4"
3'-7 3/4"
10'-7 3/8" 10'-1 1/4"
3'-11 1/4"
10'-5 3/4" 10'-4 3/8"
3'-7 3/4"
10'-1 7/8" 11'-0 1/4"
3'-7 3/4"
10'-6 3/4" 6'-0"
104'-11 3/8"
UNIT 1
797 GSF
39'-5 1/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
A2.2
3
4 A2.2
A2.2
1
A2.2 2
UNIT 2
781 GSF
UNIT 3
781 GSF
UNIT 4
1005 GSF
ROOF SHOWN
DASHED
RECESSED LIGHT
FIXTURE (E1) ABOVE,
RE: SHEET A1.5
RECESSED LIGHT
FIXTURE (E1) ABOVE,
RE: SHEET A1.5
1 2 4 6 7
A
D
8 9 10
B
E
3 5
C
11 12 13 14
10'-9 1/4"
3'-7 3/4"
10'-7 3/8" 10'-1 1/4"
3'-11 1/4"
10'-5 3/4" 10'-4 3/8"
3'-7 3/4"
10'-1 7/8" 11'-0 1/4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
1 2 4 6 7
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
3 5 8 9 10
98' - 6"
GARAGE
129' - 4"
TO ROOF
11 12 13 14
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
1'-6" 9'-1 1/8"
29'-4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
7 6 4 2 1
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
10 9 8 5 3
98' - 6"
GARAGE
129' - 4"
TO ROOF
14 13 12 11
29'-4"
10'-7 1/8"
1'-0 5/8"
9'-1 1/8" 10'-1 1/8"
A/C CONDENSER
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
1'-6" 9'-1 1/8"
29'-4"
100' - 0"
LEVEL 1
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
7 6 4 2 1
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
10 9 8 5 3
98' - 6"
GARAGE
129' - 4"
TO ROOF
14 13 12 11
29'-4"
1'-6"
9'-1 1/8"
1'-0 5/8"
9'-1 1/8" 10'-1 1/8"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
1 2 4 6 7
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
3 5 8 9 10
98' - 6"
GARAGE
129' - 4"
TO ROOF
11 12 13 14
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 2:55:57 PM
A2.4
3D VIEWS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING D
(BUILDING G SIMILAR)
WS
CR
4 3D VIEW OF FRONT
2 3D VIEW OF FRONT
UP UP UP
UP UP UP
UP
4 5 7 9 10
A
D
11 12 13
B
E
6 8
C
1 2 3 14 15 16
10'-5 3/4"
3'-11 1/4"
10'-6 3/4" 10'-1 7/8"
3'-11 1/4"
10'-3" 10'-3 5/8"
3'-11 1/4"
10'-4" 10'-4 5/8"
3'-11 1/4"
10'-0 1/4" 10'-7 3/8"
3'-10 1/4"
16'-9 1/8"
129'-5 5/8"
39'-5 1/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
A3.2
1
4 A3.2
A3.2
2
A3.2 3
UNIT 1
781 GSF
UNIT 2
768 GSF
UNIT 3
768 GSF
UNIT 4
775 GSF
UNIT 5
976 GSF
ROOF LINE
ABOVE
RECESSED LIGHT
FIXTURE (E1) ABOVE,
RE: SHEET A1.5
RECESSED LIGHT
FIXTURE (E1) ABOVE,
RE: SHEET A1.5
4 5 7 9 10
A A
D D
11 12 13
B B
E E
6 8
C C
1 2 3 14 15 16
10'-5 3/4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
4 5 7 9 10
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
6 8 11 12 13
98' - 6"
GARAGE
129' - 4"
TO ROOF
1 2 3 14 15 16
1
9'-1 1/8" 0'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
10 9 7 5 4
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
13 12 11 8 6
98' - 6"
GARAGE
129' - 4"
TO ROOF
16 14
15 3 2 1
29'-4"
1'-6"
9'-1 1/8"
1'-0 5/8"
9'-1 1/8" 10'-1 1/8"
A/C CONDENSER
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
4 5 7 9 10
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
6 8 11 12 13
98' - 6"
GARAGE
129' - 4"
TO ROOF
1 2 3 14 15 16
1
9'-1 1/8" 0'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
10 9 7 5 4
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
13 12 11 8 6
98' - 6"
GARAGE
129' - 4"
TO ROOF
16 14
15 3 2 1
29'-4"
1'-6"
9'-1 1/8"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
4 5 7 9 10
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
6 8 11 12 13
98' - 6"
GARAGE
129' - 4"
TO ROOF
1 2 3 14 15 16
1
9'-1 1/8" 0'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
10 9 7 5 4
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
13 12 11 8 6
98' - 6"
GARAGE
129' - 4"
TO ROOF
16 14
15 3 2 1
29'-4"
1'-6"
9'-1 1/8"
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 3:21:12 PM
A3.4
3D VIEWS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING L
(BUILDING C SIMILAR)
WS
CR
1 3D VIEW OF FRONT
2 3D VIEW OF FRONT
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 3:11:32 PM
A3.4A
3D VIEWS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING I
(BUILDING H SIMILAR)
WS
CR
4 3D VIEW OF FRONT 1 3D VIEW OF FRONT
3 3D VIEW OF BACK
UP UP UP UP
UP UP UP
UP UP
4 5 7 9
A
D
12 13
B
E
6 8
C
1 2 3
10'-9 1/4" 3'-7 3/4" 10'-7 3/8" 10'-1 1/4" 3'-11 1/4" 10'-6 3/8" 10'-3 3/4" 3'-7 3/4" 20'-8 5/8" 3'-11 1/4" 10'-6 3/8" 10'-3 3/4" 3'-7 3/4" 10'-6 3/4" 10'-1 7/8" 14'-5"
147'-10 1/8"
39'-5 1/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
UNIT 1
781 GSF
UNIT 2
761 GSF
UNIT 3
768 GSF
UNIT 4
781 GSF
A4.2
1
4 A4.2
A4.2
2
A4.2 3
11 14 15 16 17 18
UNIT 5
781 GSF
UNIT 6
781 GSF
RECESSED LIGHT
FIXTURE (E1) ABOVE,
RE: SHEET A1.5
RECESSED LIGHT
FIXTURE (E1) ABOVE,
RE: SHEET A1.5
4 5 7 9
A
D
12 13
B
E
6 8
C
1 2 3
10'-9 1/4" 3'-7 3/4" 10'-7 3/8" 10'-1 1/4" 3'-11 1/4" 10'-6 3/8" 10'-3 3/4" 3'-7 3/4" 20'-8 5/8" 3'-11 1/4" 10'-6 3/8" 10'-3 3/4" 3'-7 3/4" 10'-6 3/4" 10'-1 7/8" 14'-5"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
39'-5 1/4"
147'-10 1/8"
6:12
6:12
4:12 4:12 4:12 4:12
A4.2
1
4 A4.2
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
4 5 7 9
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
6 8 12 13
98' - 6"
GARAGE
132' - 5"
TO ROOF
1 2 3 11 14 15 16 17 18
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
9 7 5 4
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
13 12 8 6
98' - 6"
GARAGE
132' - 5"
TO ROOF
3 2 1
32'-5"
10'-7 1/8"
1'-0 5/8"
9'-1 1/8" 13'-2 1/8"
18 17 16 15 14 11
A/C CONDENSER
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
4 5 7 9
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
6 8 12 13
98' - 6"
GARAGE
132' - 5"
TO ROOF
1 2 3 11 14 15 16 17 18
33'-11"
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
9 7 5 4
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
13 12 8 6
98' - 6"
GARAGE
132' - 5"
TO ROOF
3 2 1
32'-5"
10'-7 1/8"
1'-0 5/8"
9'-1 1/8" 13'-2 1/8"
18 17 16 15 14 11
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
4 5 7 9
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
6 8 12 13
98' - 6"
GARAGE
132' - 5"
TO ROOF
1 2 3 11 14 15 16 17 18
33'-11"
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
9 7 5 4
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
13 12 8 6
98' - 6"
GARAGE
132' - 5"
TO ROOF
3 2 1
32'-5"
10'-7 1/8"
1'-0 5/8"
9'-1 1/8" 13'-2 1/8"
18 17 16 15 14 11
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 12:34:39 PM
A4.4
3D VIEWS
KECHTER
TOWNHOMES
Project # 19_014_00
PDP SUBMITTAL
BUILDING A
(BUILDING K SIMILAR)
WS
CR
2 3D VIEW OF FRONT
4 3D VIEW OF FRONT 1 3D VIEW OF FRONT
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 1:53:43 PM
A4.4A
3D VIEWS
KECHTER
TOWNHOMES
Project # 19_014_00
PDP SUBMITTAL
BUILDING E
(BUILDING J SIMILAR)
WS
CR
2 3D VIEW OF FRONT
4 3D VIEW OF FRONT 1 3D VIEW OF FRONT
3 3D VIEW OF BACK
5 3D VIEW OF BACK
6 3D VIEW OF BACK
1 PDP SUBMITTAL 07/22/2020
3 3D VIEW OF BACK
5 3D VIEW OF BACK
6 3D VIEW OF BACK
1 PDP SUBMITTAL 07/22/2020
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
EXTERIOR COLORS
ROOFING - LIGHT GRAY
COLOR 01 - SHERWIN WILLIAMS "ACACIA HAZE"
COLOR 02 - SHERWIN WILLIAMS "REDDENED EARTH"
COLOR 03 - SHERWIN WILLIAMS "MANOR HOUSE"
COLOR 04 - SHERWIN WILLIAMS "DRIFT OF MIST"
COLOR 05 - SHERWIN WILLIAMS "MOTH WING"
COLOR 06 - SHERWIN WILLIAMS "EXTRA WHITE"
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 1:52:58 PM
A4.3A
COLOR ELEVATIONS
KECHTER
TOWNHOMES
Project # 19_014_00
PDP SUBMITTAL
BUILDING E
(BUILDING J SIMILAR)
WS
CR
1 FRONT 1/8" = 1'-ELEVATION 0"
4 SIDE 1/8" = ELEVATION 1'-0"
2 REAR 1/8" = 1'-ELEVATION 0"
3 SIDE 1/8" = ELEVATION 1'-0"
0 8 16 24 32
GRAPHIC SCALE
0 8 16 24 32
GRAPHIC SCALE
0 8 16 24 32
GRAPHIC SCALE
0 8 16 24 32
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
EXTERIOR COLORS
ROOFING - CHARCOAL
COLOR 01 - SHERWIN WILLIAMS "SLATE TILE"
COLOR 02 - SHERWIN WILLIAMS "REDDENED EARTH"
COLOR 03 - SHERWIN WILLIAMS "GARDENIA"
COLOR 04 - SHERWIN WILLIAMS "DRIFT OF MIST"
COLOR 05 - SHERWIN WILLIAMS "MOTH WING"
COLOR 06 - SHERWIN WILLIAMS "EXTRA WHITE"
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 1:59:23 PM
A4.3
COLOR ELEVATIONS
KECHTER
TOWNHOMES
Project # 19_014_00
PDP SUBMITTAL
BUILDING A
(BUILDING K SIMILAR)
WS
CR
1 FRONT 1" = 10'-0" ELEVATION
4 SIDE 1" = 10'-ELEVATION 0"
2 REAR 1" = 10'-ELEVATION 0"
3 SIDE 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 12:33:18 PM
A4.2
ELEVATIONS
KECHTER
TOWNHOMES
Project # 19_014_00
PDP SUBMITTAL
BUILDING A
(BUILDING K SIMILAR)
WS
CR
1 FRONT 1" = 10'-0" ELEVATION
2 REAR 1" = 10'-ELEVATION 0"
3 SIDE 1" = 10'-ELEVATION 0"
4 SIDE 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
A4.2
2
A4.2 3
UNIT 1
781 GSF
UNIT 2
761 GSF
UNIT 3
768 GSF
UNIT 4
781 GSF
11 14 15 16 17 18
6:12
4:12 4:12
UNIT 5
781 GSF
6:12
UNIT 6
781 GSF
OPEN TO
GARAGE
BELOW
4 5 7 9
A
D
12 13
B
E
6 8
C
1 2 3
147'-10 1/8"
10'-9 1/4"
3'-7 3/4"
10'-7 3/8" 10'-1 1/4"
3'-11 1/4"
10'-6 3/8" 10'-3 3/4"
3'-7 3/4"
20'-8 5/8"
3'-11 1/4"
10'-6 3/8" 10'-3 3/4"
3'-7 3/4"
10'-6 3/4" 10'-1 7/8" 14'-5"
9:12
9:12
8:12 8:12
A4.2
1
4 A4.2
A4.2
2
A4.2 3
11 14 15 16 17 18
39'-5 1/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
6:12 6:12
6:12
8:12
6:12
6:12
9:12
9:12
9:12
6:12
8:12
9:12
6:12
9:12
9:12
9:12
9:12
9:12
9:12 9:12
9:12 9:12 9:12 9:12
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/21/2020 2:28:52 PM
A4.1
FLOOR PLANS
KECHTER
TOWNHOMES
Project # 19_014_00
PDP SUBMITTAL
BUILDING A
(BUILDING K SIMILAR)
WS
CR
1 LEVEL 1" = 10'-1 0"
2 LEVEL 1" = 10'-2 0"
3 ROOF 1" = 10'-PLAN 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
5 3D VIEW OF BACK 2 3D VIEW OF FRONT
6 3D VIEW OF BACK
1 PDP SUBMITTAL 07/22/2020
3 3D VIEW OF BACK
1 PDP SUBMITTAL 07/22/2020
5 3D VIEW OF BACK
6 3D VIEW OF BACK
4 3D VIEW OF FRONT
1'-0 5/8"
9'-1 1/8" 10'-1 1/8"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING - CHARCOAL
COLOR 01 - SHERWIN WILLIAMS "UNCERTAIN GRAY"
COLOR 02 - SHERWIN WILLIAMS "ALMOND ROCA"
COLOR 03 - SHERWIN WILLIAMS "EXTRA WHITE"
COLOR 04 - SHERWIN WILLIAMS "DISTANCE"
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 3:10:46 PM
A3.3A
COLOR ELEVATIONS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING I
(BUILDING H SIMILAR)
WS
CR
1 FRONT 1" = 10'-0" ELEVATION
4 SIDE 1" = 10'-ELEVATION 0"
2 REAR 1" = 10'-ELEVATION 0"
3 SIDE 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
1'-0 5/8"
9'-1 1/8" 10'-1 1/8"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
ELEVATION LEGEND
SMOOTH HORIZONTAL CEMENT BOARD LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
EXTERIOR COLORS
ROOFING - CHARCOAL
COLOR 01 - SHERWIN WILLIAMS "CITYSCAPE"
COLOR 02 - SHERWIN WILLIAMS "ROJO DUST"
COLOR 03 - SHERWIN WILLIAMS "EXTRA WHITE"
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 3:20:21 PM
A3.3
COLOR ELEVATIONS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING L
(BUILDING C SIMILAR)
WS
CR
1 FRONT 1" = 10'-0" ELEVATION
4 SIDE 1" = 10'-ELEVATION 0"
2 REAR 1" = 10'-ELEVATION 0"
3 SIDE 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
9'-1 1/8"
1'-6"
29'-4"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
ELEVATION LEGEND
SMOOTH HORIZONTAL CEMENT BOARD LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 3:20:03 PM
A3.2
ELEVATIONS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING L
(BUILDING C SIMILAR)
WS
CR
1 FRONT 1" = 10'-0" ELEVATION
0 10 20 30 40
GRAPHIC SCALE
2 REAR 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
3 SIDE 1" = 10'-ELEVATION 0"
4 SIDE 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
3'-11 1/4"
10'-6 3/4" 10'-1 7/8"
3'-11 1/4"
10'-3" 10'-3 5/8"
3'-11 1/4"
10'-4" 10'-4 5/8"
3'-11 1/4"
10'-0 1/4" 10'-7 3/8"
3'-10 1/4"
16'-9 1/8"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
39'-5 1/4"
129'-5 5/8"
4:12
4:12
4:12
4:12
8:12 8:12
A3.2
1
4 A3.2
A3.2
2
A3.2 3
UNIT 1
768 GSF
UNIT 2
768 GSF
UNIT 3
775 GSF
UNIT 4
506 GSF
UNIT 1
781 GSF
ROOF LINE
ABOVE
4 5 7 9 10
A
D
11 12 13
B
E
6 8
C
1 2 3 14 15 16
4:12
129'-5 5/8"
10'-5 3/4"
3'-11 1/4"
10'-6 3/4" 10'-1 7/8"
3'-11 1/4"
10'-3" 10'-3 5/8"
3'-11 1/4"
10'-4" 10'-4 5/8"
3'-11 1/4"
10'-0 1/4" 10'-7 3/8"
3'-10 1/4"
16'-9 1/8"
39'-5 1/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
4:12
4:12
6:12 6:12
6:12
8:12 8:12
8:12 8:12
6:12 6:12
6:12 6:12
8:12 8:12
4:12
8:12 8:12
A3.2
1
4 A3.2
A3.2
2
A3.2 3
6:12 6:12
8:12
8:12 8:12
8:12
8:12 8:12
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/21/2020 1:26:59 PM
A3.1
FLOOR PLANS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING L
(BUILDING C SIMILAR)
WS
CR
1 LEVEL 1" = 10'-1 0"
2 LEVEL 1" = 10'-2 0"
3 ROOF 1" = 10'-PLAN 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
3 3D VIEW OF BACK
1 PDP SUBMITTAL 07/22/2020
1 3D VIEW OF FRONT
5 3D VIEW OF BACK
6 3D VIEW OF BACK
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
EXTERIOR COLORS
ROOFING - CHARCOAL
COLOR 01 - SHERWIN WILLIAMS "EXTRA WHITE"
COLOR 02 - SHERWIN WILLIAMS "CITYSCAPE"
COLOR 03 - SHERWIN WILLIAMS "BRICK PAVER"
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 2:55:05 PM
A2.3
COLOR ELEVATIONS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING D
(BUILDING G SIMILAR)
WS
CR
3 REAR 1" = 10'-ELEVATION 0"
4 SIDE 1" = 10'-ELEVATION 0"
1 FRONT 1" = 10'-0" ELEVATION
2 SIDE 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
109' - 1 1/8"
TO PLATE LEVEL 1
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
129' - 4"
TO ROOF
9'-1 1/8" 10'-1 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
29'-4"
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 2:54:50 PM
A2.2
ELEVATIONS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING D
(BUILDING G SIMILAR)
WS
CR
1 FRONT 1" = 10'-0" ELEVATION
3 REAR 1" = 10'-ELEVATION 0"
2 SIDE 1" = 10'-ELEVATION 0"
4 SIDE 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
3'-7 3/4"
16'-6 3/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
39'-5 1/4"
104'-11 3/8"
4:12
6:12
6:12
6:12
6:12
A2.2
3
4 A2.2
A2.2
1
A2.2 2
UNIT 1
796 GSF
UNIT 2
782 GSF
UNIT 3
782 GSF
UNIT 4
436 GSF
6:12 6:12
ROOF SHOWN
DASHED
1 2 4 6 7
A
D
8 9 10
B
E
3 5
C
11 12 13 14
104'-11 3/8"
10'-9 1/4"
3'-7 3/4"
10'-7 3/8" 10'-1 1/4"
3'-11 1/4"
10'-5 3/4" 10'-4 3/8"
3'-7 3/4"
10'-1 7/8" 11'-0 1/4"
3'-7 3/4"
10'-6 3/4" 6'-0"
39'-5 1/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
4:12
6:12 6:12
9:12 9:12 9:12
9:12
A2.2
3
4 A2.2
A2.2
1
A2.2 2
9:12 9:12
6:12 6:12
6:12 6:12
6:12 6:12
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/21/2020 12:26:35 PM
A2.1
FLOOR PLANS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING D
(BUILDING G SIMILAR)
WS
CR
1 LEVEL 1" = 10'-1 0"
2 LEVEL 1" = 10'-2 0"
3 ROOF 1" = 10'-PLAN 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
5 1/2"
FIBER CEMENT TRIM SYSTEM
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/21/2020 11:55:01 AM
A1.5
TYPICAL DETAILS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
WS
CR
1 WINDOW 3" = 1'-0" SILL @ FIBER CEMENT LAP SIDING
2 WINDOW 3" = 1'-0" JAMB @ FIBER CEMENT LAP SIDING
3 WINDOW 3" = 1'-0" HEAD @ FIBER CEMENT LAP SIDING
4 WINDOW 3" = 1'-0" SILL @ FIBER CEMENT PANEL
5 WINDOW 3" = 1'-0" JAMB @ FIBER CEMENT PANEL
6 WINDOW 3" = 1'-0" HEAD @ FIBER CEMENT PANEL
1 PDP SUBMITTAL 07/22/2020
1 3D VIEW OF FRONT
6BACK 3D VIEW OF BACK 3 3D VIEW OF
5 3D VIEW OF BACK
1 PDP SUBMITTAL 07/22/2020
11 10
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
A D
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
B E
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
EXTERIOR COLORS
ROOFING - MEDIUM BROWN
COLOR 01 - SHERWIN WILLIAMS "LAZY GRAY"
COLOR 02 - SHERWIN WILLIAMS "SERIOUS GRAY"
COLOR 03 - SHERWIN WILLIAMS "EXTRA WHITE"
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 2:41:48 PM
A1.3
COLOR ELEVATIONS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING B
(BUILDING F SIMILAR)
WS
CR
1 FRONT 1" = 10'-0" ELEVATION
4 SIDE 1" = 10'-ELEVATION 0"
3 REAR 1" = 10'-ELEVATION 0"
2 SIDE 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
1'-6"
32'-5"
100' - 0"
LEVEL 1
109' - 1 1/8"
TO PLATE LEVEL 1
D A
110' - 1 3/4"
LEVEL 2
119' - 2 7/8"
TO PLATE LEVEL 2
E B
98' - 6"
GARAGE
C
132' - 5"
TO ROOF
9'-1 1/8" 13'-2 1/8"
1'-0 5/8"
9'-1 1/8"
1'-6"
32'-5"
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/20/2020 2:41:04 PM
A1.2
ELEVATIONS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING B
(BUILDING F SIMILAR)
WS
CR
1 FRONT 1" = 10'-0" ELEVATION
3 REAR 1" = 10'-ELEVATION 0"
2 SIDE 1" = 10'-ELEVATION 0"
4 SIDE 1" = 10'-ELEVATION 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020
3'-11 1/4"
10'-6 3/4" 10'-1 7/8"
3'-11 1/4"
10'-5 3/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
39'-5 1/4"
98'-8 3/8"
4:12
4:12
4:12
4:12 4:12 4:12 4:12
A1.2
1
4 A1.2
A1.2
3
A1.2 2
UNIT 1
781 GSF
UNIT 2
761 GSF
UNIT 3
768 GSF
UNIT 4
781 GSF
10 11
ROOF SHOWN
DASHED
4 5 7 9
A
D
12 13
B
E
6 8
C
1 2 3
98'-8 3/8"
10'-9 1/4"
3'-7 3/4"
10'-7 3/8" 10'-1 1/4"
3'-11 1/4"
10'-6 3/8" 10'-0 1/4"
3'-11 1/4"
10'-6 3/4" 10'-1 7/8"
3'-11 1/4"
10'-5 3/4"
39'-5 1/4"
5'-2 1/4" 4'-10" 26'-3" 3'-2"
9:12 9:12
8:12
9:12 9:12
9:12 9:12
9:12 9:12
9:12
9:12
8:12 8:12
A1.2
1
4 A1.2
A1.2
3
A1.2 2
10 11
9:12
9:12
8:12 8:12
8:12 8:12
8:12 8:12
8:12
9:12
9:12
9:12
9:12
9:12 9:12
KEY PLAN
B
C
D E
F
G
H
I
J K
L
A
COPYRIGHT
PLOT DATE:
C
PROJECT No:
Sheet Issue & Revision Log
No DescriptionDate
DRAWN BY:
REVIEWED BY:
DRAWING NUMBER:
SEAL:
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
ORIGINAL SIZE 24X36
No
REVISIONS
FORT COLLINS, CO
PREPARED BY:
FORT COLLINS, CO
KECHTER TWG, LLP.
Ryan Kelly
p. 317.559.7009
e. rkelly@twgdev.com
ARCHITECT
STUDIO ARCHITECTURE
Aldo Sebben
3575 Ringsby Ct. Suite 300C
Denver, CO 80216
p. 303.250.9525
ENGINEER
NORTHERN ENGINEERING
Andy Reese
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4158
It is the client's responsibility prior to or during construction to notify the
architect in writing of any perceived errors or omissions in the plans and
specifications of which a contractor thoroughly knowledgeable with the
building codes and methods of construction should reasonably be aware.
Written instructions addressing such perceived errors or omissions shall be
received from the architect prior to the client or client's subcontractors
proceeding with the work. The client shall be responsible for any defects in
construction if these procedures are not followed.
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 fax 970.225.6657 www.ripleydesigninc.com
DescriptionDate
7/21/2020 11:52:16 AM
A1.1
FLOOR PLANS
KECHTER
TOWNHOMES
19_014_00
PDP SUBMITTAL
BUILDING B
(BUILDING F SIMILAR)
WS
CR
1 LEVEL 1" = 10'-1 0"
2 LEVEL 1" = 10'-2 0"
3 ROOF 1" = 10'-PLAN 0"
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
0 10 20 30 40
GRAPHIC SCALE
1 PDP SUBMITTAL 07/22/2020