HomeMy WebLinkAboutMOSAIC CONDOS - FDP200012 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONS9'-1" 9'-1"
32'-0" TYP. BUILDING HEIGHT
MEASURED FROM FFE TO TOP OF HIGHEST RIDGE
9'-1" 9'-1" 9'-1" 9'-1"
9'-1" 9'-1"
1
A-01
8-PLEX FRONT ELEVATION
SCALE: 1/4" = 1'-0"
2
A-01
8-PLEX FRONT ELEVATION
SCALE: 1/4" = 1'-0"
3
A-01
8-PLEX LEFT ELEVATION
SCALE: 1/4" = 1'-0"
4
A-01
8-PLEX RIGHT ELEVATION
SCALE: 1/4" = 1'-0"
ELEVATION NOTES
1. ELEVATION DRAWINGS DEPICT
DESIGN INTENT ONLY. SEE
STRUCTURAL DRAWINGS FOR
FOUNDATION AND FRAMING
SPECIFICATIONS.
2. GRADE LINES INDICATED ARE
APPROXIMATE. BUILDER TO
COORDINATE SITE SPECIFIC
GRADING AT EACH LOT. PROVIDE
POSITIVE SLOPE GRADING AWAY
FROM STRUCTURE AT EACH LOT.
3. TYPICAL WINDOW HEAD HEIGHT FOR
FIRST FLOOR IS 8'-1" ABOVE T.O.
SUB-FLOOR U.N.O., AND 8'-1" ABOVE
T.O. SUB-FLOOR FOR SECOND
FLOOR. REFER TO ELEVATIONS FOR
NON-TYPICAL CONDITIONS.
4. FENCING IS SHOWN FOR DESIGN
INTENT ONLY. ACTUAL MATERIALS
AND DESIGN MAY VARY PER
BUILDER SPECIFICATION.
5. REFER TO ROOF PLANS FOR
ROOFING MATERIAL AND SLOPE.
6. GUTTERS AND DOWNSPOUTS SHALL
BE INSTALLED AT ALL ROOF
DRAINAGE CONDITIONS.
COORDINATE LOCATIONS WITH
BUILDER.
7. ENCLOSED FIRE-RISER, COORD.
WITH CIVIL.
8. SCREENED ELECTRICAL METERS,
COORD. WITH ELECTRICAL.
9. ALL EXTERIOR LIGHT FIXTURES TO
HAVE FULL CUT OFF LIGHT. AVOID
LIGHT TRESPASSING TO ADJACENT
PROPERTIES. ALL LIGHT FIXTURES
TO COMPLY WITH LOCAL CODES.
PLAN NOTES
9'-1" 9'-1"
28'-3" TYP. BUILDING HEIGHT
MEASURED FROM FFE TO TOP OF HIGHEST RIDGE
9'-1" 9'-1" 9'-1" 9'-1"
9'-1" 9'-1"
ELEVATION NOTES
1. ELEVATION DRAWINGS DEPICT
DESIGN INTENT ONLY. SEE
STRUCTURAL DRAWINGS FOR
FOUNDATION AND FRAMING
SPECIFICATIONS.
2. GRADE LINES INDICATED ARE
APPROXIMATE. BUILDER TO
COORDINATE SITE SPECIFIC
GRADING AT EACH LOT. PROVIDE
POSITIVE SLOPE GRADING AWAY
FROM STRUCTURE AT EACH LOT.
3. TYPICAL WINDOW HEAD HEIGHT FOR
FIRST FLOOR IS 8'-1" ABOVE T.O.
SUB-FLOOR U.N.O., AND 8'-1" ABOVE
T.O. SUB-FLOOR FOR SECOND
FLOOR. REFER TO ELEVATIONS FOR
NON-TYPICAL CONDITIONS.
4. FENCING IS SHOWN FOR DESIGN
INTENT ONLY. ACTUAL MATERIALS
AND DESIGN MAY VARY PER
BUILDER SPECIFICATION.
5. REFER TO ROOF PLANS FOR
ROOFING MATERIAL AND SLOPE.
6. GUTTERS AND DOWNSPOUTS SHALL
BE INSTALLED AT ALL ROOF
DRAINAGE CONDITIONS.
COORDINATE LOCATIONS WITH
BUILDER.
7. ENCLOSED FIRE-RISER, COORD.
WITH CIVIL.
8. SCREENED ELECTRICAL METERS,
COORD. WITH ELECTRICAL.
9. ALL EXTERIOR LIGHT FIXTURES TO
HAVE FULL CUT OFF LIGHT. AVOID
LIGHT TRESPASSING TO ADJACENT
PROPERTIES. ALL LIGHT FIXTURES
TO COMPLY WITH LOCAL CODES.
PLAN NOTES
FIRST FLOOR - GROSS BUILDING AREA
SECOND FLOOR - GROSS BUILDING AREA
NOTE: ALL SQUARE FOOTAGES ARE MEASURED TO EXTERIOR EDGE OF FRAMING AND
INCLUDE COVERED PATIO AND DECKS. TOTALS REPRESENT DESIGN INTENT ONLY AND
ARE SUBJECT TO CHANGE.
7,846 SQ. FT.
6,855 SQ. FT.
ELEVATION KEYNOTES
01
02
03
07
ASPHALT SHINGLE ROOF
04
05
HORIZONTAL SIDING, 8" REVEAL
9'-1" 9'-1"
28'-10" TYP. BUILDING HEIGHT
MEASURED FROM FFE TO TOP OF HIGHEST RIDGE
9'-1" 9'-1" 9'-1" 9'-1"
9'-1" 9'-1"
ELEVATION NOTES
1. ELEVATION DRAWINGS DEPICT
DESIGN INTENT ONLY. SEE
STRUCTURAL DRAWINGS FOR
FOUNDATION AND FRAMING
SPECIFICATIONS.
2. GRADE LINES INDICATED ARE
APPROXIMATE. BUILDER TO
COORDINATE SITE SPECIFIC
GRADING AT EACH LOT. PROVIDE
POSITIVE SLOPE GRADING AWAY
FROM STRUCTURE AT EACH LOT.
3. TYPICAL WINDOW HEAD HEIGHT FOR
FIRST FLOOR IS 8'-1" ABOVE T.O.
SUB-FLOOR U.N.O., AND 8'-1" ABOVE
T.O. SUB-FLOOR FOR SECOND
FLOOR. REFER TO ELEVATIONS FOR
NON-TYPICAL CONDITIONS.
4. FENCING IS SHOWN FOR DESIGN
INTENT ONLY. ACTUAL MATERIALS
AND DESIGN MAY VARY PER
BUILDER SPECIFICATION.
5. REFER TO ROOF PLANS FOR
ROOFING MATERIAL AND SLOPE.
6. GUTTERS AND DOWNSPOUTS SHALL
BE INSTALLED AT ALL ROOF
DRAINAGE CONDITIONS.
COORDINATE LOCATIONS WITH
BUILDER.
7. ENCLOSED FIRE-RISER, COORD.
WITH CIVIL.
8. SCREENED ELECTRICAL METERS,
COORD. WITH ELECTRICAL.
9. ALL EXTERIOR LIGHT FIXTURES TO
HAVE FULL CUT OFF LIGHT. AVOID
LIGHT TRESPASSING TO ADJACENT
PROPERTIES. ALL LIGHT FIXTURES
TO COMPLY WITH LOCAL CODES.
PLAN NOTES
FIRST FLOOR - GROSS BUILDING AREA
SECOND FLOOR - GROSS BUILDING AREA
NOTE: ALL SQUARE FOOTAGES ARE MEASURED TO EXTERIOR EDGE OF FRAMING AND
INCLUDE COVERED PATIO AND DECKS. TOTALS REPRESENT DESIGN INTENT ONLY AND
ARE SUBJECT TO CHANGE.
7,846 SQ. FT.
6,855 SQ. FT.
ELEVATION KEYNOTES
01
02
03
07
ASPHALT SHINGLE ROOF
04
05
HORIZONTAL SIDING, (2) 7" REVEAL & (1) 5" REVEAL, OR SIM.
1
A-04
8-PLEX - FARMHOUSE - FRONT PERSPECTIVE VIEW
SCALE: 1/4" = 1'-0"
2
A-04
8-PLEX - CRAFTSMAN - FRONT PERSPECTIVE VIEW
SCALE: 1/4" = 1'-0"
3
A-04
8-PLEX - MID-CENTURY MODERN - FRONT PERSPECTIVE VIEW
SCALE: 1/4" = 1'-0"
8-PLEX
PERSPECTIVE VIEWS
A-04
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
REV. COMMENT DATE
OL, SH
OL, CVH, MM
02.05.2020
PRELIMINARY
EAST RIDGE FIFTH FILING
PDP SUBMITTAL
www.dtjdesign.com
DTJ DESIGN, Inc.
3101 Iris Avenue, Suite 130
Boulder, Colorado 80301
T 303.443.7533
FDP SUBMITTAL 1
FDP SUBMITTAL
PATTERNED BOARD AND BATTEN SIDING
STANDING SEAM METAL ROOF
8'-0" ENTRY DOOR
STUCCO, OR SIM.
NOTE: ALL MATERIALS ARE FOR DESIGN INTENT ONLY AND MAY VARY PER BUILDER
SPECIFICATION.
06
PAINTED TRIM, SMOOTH FINISH
08
09 8'-0" GARAGE DOOR
PRE-STAINED COMPOSITE SIDING
10 EXTERIOR SCONCE LIGHT
11 SCREENED ELECTRICAL METERS, COORD. W/ CIVIL
12 ENCLOSED FIRE RISER ROOM, COORD. W/ CIVIL
01
02
03
04 05
06
07
11 09 12
8-PLEX MID-CENTURY
MODERN ELEVATIONS
A-03
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
REV. COMMENT DATE
OL, SH
OL, CVH, MM
02.05.2020
PRELIMINARY
EAST RIDGE FIFTH FILING
PDP SUBMITTAL
www.dtjdesign.com
DTJ DESIGN, Inc.
3101 Iris Avenue, Suite 130
Boulder, Colorado 80301
T 303.443.7533
1
A-03
8-PLEX FRONT ELEVATION
SCALE: 1/4" = 1'-0"
2
A-03
8-PLEX FRONT ELEVATION
SCALE: 1/4" = 1'-0"
3
A-03
8-PLEX LEFT ELEVATION
SCALE: 1/4" = 1'-0"
4
A-03
8-PLEX RIGHT ELEVATION
SCALE: 1/4" = 1'-0"
FDP SUBMITTAL 1
FDP SUBMITTAL
SHINGLE SIDING
8'-0" ENTRY DOOR
NOTE: ALL MATERIALS ARE FOR DESIGN INTENT ONLY AND MAY VARY PER BUILDER
SPECIFICATION.
06
PAINTED TRIM, SMOOTH FINISH
ARCHITECTURAL BRACKET
8'-0" GARAGE DOOR
08 EXTERIOR SCONCE LIGHT
09
10
SCREENED ELECTRICAL METERS, COORD. W/ CIVIL
ENCLOSED FIRE RISER ROOM, COORD. W/ CIVIL
01
02
03 04 05
05
07
08 06
1
A-02
8-PLEX FRONT ELEVATION
SCALE: 1/4" = 1'-0"
2
A-02
8-PLEX FRONT ELEVATION
SCALE: 1/4" = 1'-0"
3
A-02
8-PLEX LEFT ELEVATION
SCALE: 1/4" = 1'-0"
4
A-02
8-PLEX RIGHT ELEVATION
SCALE: 1/4" = 1'-0"
09 10
8-PLEX FARMHOUSE
ELEVATIONS
A-02
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
REV. COMMENT DATE
OL, SH
OL, CVH, MM
02.05.2020
PRELIMINARY
EAST RIDGE FIFTH FILING
PDP SUBMITTAL
www.dtjdesign.com
DTJ DESIGN, Inc.
3101 Iris Avenue, Suite 130
Boulder, Colorado 80301
T 303.443.7533
FDP SUBMITTAL 1
FDP SUBMITTAL
FIRST FLOOR - GROSS BUILDING AREA
SECOND FLOOR - GROSS BUILDING AREA
NOTE: ALL SQUARE FOOTAGES ARE MEASURED TO EXTERIOR EDGE OF FRAMING AND
INCLUDE COVERED PATIO AND DECKS. TOTALS REPRESENT DESIGN INTENT ONLY AND
ARE SUBJECT TO CHANGE.
7,846 SQ. FT.
6,855 SQ. FT.
ELEVATION KEYNOTES
01
02
03
07
ASPHALT SHINGLE ROOF
04
05
HORIZONTAL SIDING, 7" REVEAL
BOARD AND BATTEN SIDING
STANDING SEAM METAL ROOF
8'-0" ENTRY DOOR
HORIZONTAL SIDING, 4" REVEAL
NOTE: ALL MATERIALS ARE FOR DESIGN INTENT ONLY AND MAY VARY PER BUILDER
SPECIFICATION.
06 PAINTED TRIM, SMOOTH FINISH
08
8'-0" GARAGE DOOR
DECORATIVE GABLE VENT
09
10 EXTERIOR SCONCE LIGHT
11
12
SCREENED ELECTRICAL METERS, COORD. W/ CIVIL
ENCLOSED FIRE RISER ROOM, COORD. W/ CIVIL
01
02
04
03
05
06
06
07 05 07
05
02
08
09
10
10
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
REV. COMMENT DATE
OL, SH
OL, CVH, MM
02.05.2020
PRELIMINARY
EAST RIDGE FIFTH FILING
PDP SUBMITTAL
www.dtjdesign.com
DTJ DESIGN, Inc.
3101 Iris Avenue, Suite 130
Boulder, Colorado 80301
T 303.443.7533
11 12
8-PLEX FARMHOUSE
ELEVATIONS
A-01
FDP SUBMITTAL 1
FDP SUBMITTAL