Loading...
HomeMy WebLinkAboutMOSAIC CONDOS - FDP200012 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONS9'-1" 9'-1" 32'-0" TYP. BUILDING HEIGHT MEASURED FROM FFE TO TOP OF HIGHEST RIDGE 9'-1" 9'-1" 9'-1" 9'-1" 9'-1" 9'-1" 1 A-01 8-PLEX FRONT ELEVATION SCALE: 1/4" = 1'-0" 2 A-01 8-PLEX FRONT ELEVATION SCALE: 1/4" = 1'-0" 3 A-01 8-PLEX LEFT ELEVATION SCALE: 1/4" = 1'-0" 4 A-01 8-PLEX RIGHT ELEVATION SCALE: 1/4" = 1'-0" ELEVATION NOTES 1. ELEVATION DRAWINGS DEPICT DESIGN INTENT ONLY. SEE STRUCTURAL DRAWINGS FOR FOUNDATION AND FRAMING SPECIFICATIONS. 2. GRADE LINES INDICATED ARE APPROXIMATE. BUILDER TO COORDINATE SITE SPECIFIC GRADING AT EACH LOT. PROVIDE POSITIVE SLOPE GRADING AWAY FROM STRUCTURE AT EACH LOT. 3. TYPICAL WINDOW HEAD HEIGHT FOR FIRST FLOOR IS 8'-1" ABOVE T.O. SUB-FLOOR U.N.O., AND 8'-1" ABOVE T.O. SUB-FLOOR FOR SECOND FLOOR. REFER TO ELEVATIONS FOR NON-TYPICAL CONDITIONS. 4. FENCING IS SHOWN FOR DESIGN INTENT ONLY. ACTUAL MATERIALS AND DESIGN MAY VARY PER BUILDER SPECIFICATION. 5. REFER TO ROOF PLANS FOR ROOFING MATERIAL AND SLOPE. 6. GUTTERS AND DOWNSPOUTS SHALL BE INSTALLED AT ALL ROOF DRAINAGE CONDITIONS. COORDINATE LOCATIONS WITH BUILDER. 7. ENCLOSED FIRE-RISER, COORD. WITH CIVIL. 8. SCREENED ELECTRICAL METERS, COORD. WITH ELECTRICAL. 9. ALL EXTERIOR LIGHT FIXTURES TO HAVE FULL CUT OFF LIGHT. AVOID LIGHT TRESPASSING TO ADJACENT PROPERTIES. ALL LIGHT FIXTURES TO COMPLY WITH LOCAL CODES. PLAN NOTES 9'-1" 9'-1" 28'-3" TYP. BUILDING HEIGHT MEASURED FROM FFE TO TOP OF HIGHEST RIDGE 9'-1" 9'-1" 9'-1" 9'-1" 9'-1" 9'-1" ELEVATION NOTES 1. ELEVATION DRAWINGS DEPICT DESIGN INTENT ONLY. SEE STRUCTURAL DRAWINGS FOR FOUNDATION AND FRAMING SPECIFICATIONS. 2. GRADE LINES INDICATED ARE APPROXIMATE. BUILDER TO COORDINATE SITE SPECIFIC GRADING AT EACH LOT. PROVIDE POSITIVE SLOPE GRADING AWAY FROM STRUCTURE AT EACH LOT. 3. TYPICAL WINDOW HEAD HEIGHT FOR FIRST FLOOR IS 8'-1" ABOVE T.O. SUB-FLOOR U.N.O., AND 8'-1" ABOVE T.O. SUB-FLOOR FOR SECOND FLOOR. REFER TO ELEVATIONS FOR NON-TYPICAL CONDITIONS. 4. FENCING IS SHOWN FOR DESIGN INTENT ONLY. ACTUAL MATERIALS AND DESIGN MAY VARY PER BUILDER SPECIFICATION. 5. REFER TO ROOF PLANS FOR ROOFING MATERIAL AND SLOPE. 6. GUTTERS AND DOWNSPOUTS SHALL BE INSTALLED AT ALL ROOF DRAINAGE CONDITIONS. COORDINATE LOCATIONS WITH BUILDER. 7. ENCLOSED FIRE-RISER, COORD. WITH CIVIL. 8. SCREENED ELECTRICAL METERS, COORD. WITH ELECTRICAL. 9. ALL EXTERIOR LIGHT FIXTURES TO HAVE FULL CUT OFF LIGHT. AVOID LIGHT TRESPASSING TO ADJACENT PROPERTIES. ALL LIGHT FIXTURES TO COMPLY WITH LOCAL CODES. PLAN NOTES FIRST FLOOR - GROSS BUILDING AREA SECOND FLOOR - GROSS BUILDING AREA NOTE: ALL SQUARE FOOTAGES ARE MEASURED TO EXTERIOR EDGE OF FRAMING AND INCLUDE COVERED PATIO AND DECKS. TOTALS REPRESENT DESIGN INTENT ONLY AND ARE SUBJECT TO CHANGE. 7,846 SQ. FT. 6,855 SQ. FT. ELEVATION KEYNOTES 01 02 03 07 ASPHALT SHINGLE ROOF 04 05 HORIZONTAL SIDING, 8" REVEAL 9'-1" 9'-1" 28'-10" TYP. BUILDING HEIGHT MEASURED FROM FFE TO TOP OF HIGHEST RIDGE 9'-1" 9'-1" 9'-1" 9'-1" 9'-1" 9'-1" ELEVATION NOTES 1. ELEVATION DRAWINGS DEPICT DESIGN INTENT ONLY. SEE STRUCTURAL DRAWINGS FOR FOUNDATION AND FRAMING SPECIFICATIONS. 2. GRADE LINES INDICATED ARE APPROXIMATE. BUILDER TO COORDINATE SITE SPECIFIC GRADING AT EACH LOT. PROVIDE POSITIVE SLOPE GRADING AWAY FROM STRUCTURE AT EACH LOT. 3. TYPICAL WINDOW HEAD HEIGHT FOR FIRST FLOOR IS 8'-1" ABOVE T.O. SUB-FLOOR U.N.O., AND 8'-1" ABOVE T.O. SUB-FLOOR FOR SECOND FLOOR. REFER TO ELEVATIONS FOR NON-TYPICAL CONDITIONS. 4. FENCING IS SHOWN FOR DESIGN INTENT ONLY. ACTUAL MATERIALS AND DESIGN MAY VARY PER BUILDER SPECIFICATION. 5. REFER TO ROOF PLANS FOR ROOFING MATERIAL AND SLOPE. 6. GUTTERS AND DOWNSPOUTS SHALL BE INSTALLED AT ALL ROOF DRAINAGE CONDITIONS. COORDINATE LOCATIONS WITH BUILDER. 7. ENCLOSED FIRE-RISER, COORD. WITH CIVIL. 8. SCREENED ELECTRICAL METERS, COORD. WITH ELECTRICAL. 9. ALL EXTERIOR LIGHT FIXTURES TO HAVE FULL CUT OFF LIGHT. AVOID LIGHT TRESPASSING TO ADJACENT PROPERTIES. ALL LIGHT FIXTURES TO COMPLY WITH LOCAL CODES. PLAN NOTES FIRST FLOOR - GROSS BUILDING AREA SECOND FLOOR - GROSS BUILDING AREA NOTE: ALL SQUARE FOOTAGES ARE MEASURED TO EXTERIOR EDGE OF FRAMING AND INCLUDE COVERED PATIO AND DECKS. TOTALS REPRESENT DESIGN INTENT ONLY AND ARE SUBJECT TO CHANGE. 7,846 SQ. FT. 6,855 SQ. FT. ELEVATION KEYNOTES 01 02 03 07 ASPHALT SHINGLE ROOF 04 05 HORIZONTAL SIDING, (2) 7" REVEAL & (1) 5" REVEAL, OR SIM. 1 A-04 8-PLEX - FARMHOUSE - FRONT PERSPECTIVE VIEW SCALE: 1/4" = 1'-0" 2 A-04 8-PLEX - CRAFTSMAN - FRONT PERSPECTIVE VIEW SCALE: 1/4" = 1'-0" 3 A-04 8-PLEX - MID-CENTURY MODERN - FRONT PERSPECTIVE VIEW SCALE: 1/4" = 1'-0" 8-PLEX PERSPECTIVE VIEWS A-04 Sheet Sheet Name Checked By: Drawn By: Date: REV. COMMENT DATE OL, SH OL, CVH, MM 02.05.2020 PRELIMINARY EAST RIDGE FIFTH FILING PDP SUBMITTAL www.dtjdesign.com DTJ DESIGN, Inc. 3101 Iris Avenue, Suite 130 Boulder, Colorado 80301 T 303.443.7533 FDP SUBMITTAL 1 FDP SUBMITTAL PATTERNED BOARD AND BATTEN SIDING STANDING SEAM METAL ROOF 8'-0" ENTRY DOOR STUCCO, OR SIM. NOTE: ALL MATERIALS ARE FOR DESIGN INTENT ONLY AND MAY VARY PER BUILDER SPECIFICATION. 06 PAINTED TRIM, SMOOTH FINISH 08 09 8'-0" GARAGE DOOR PRE-STAINED COMPOSITE SIDING 10 EXTERIOR SCONCE LIGHT 11 SCREENED ELECTRICAL METERS, COORD. W/ CIVIL 12 ENCLOSED FIRE RISER ROOM, COORD. W/ CIVIL 01 02 03 04 05 06 07 11 09 12 8-PLEX MID-CENTURY MODERN ELEVATIONS A-03 Sheet Sheet Name Checked By: Drawn By: Date: REV. COMMENT DATE OL, SH OL, CVH, MM 02.05.2020 PRELIMINARY EAST RIDGE FIFTH FILING PDP SUBMITTAL www.dtjdesign.com DTJ DESIGN, Inc. 3101 Iris Avenue, Suite 130 Boulder, Colorado 80301 T 303.443.7533 1 A-03 8-PLEX FRONT ELEVATION SCALE: 1/4" = 1'-0" 2 A-03 8-PLEX FRONT ELEVATION SCALE: 1/4" = 1'-0" 3 A-03 8-PLEX LEFT ELEVATION SCALE: 1/4" = 1'-0" 4 A-03 8-PLEX RIGHT ELEVATION SCALE: 1/4" = 1'-0" FDP SUBMITTAL 1 FDP SUBMITTAL SHINGLE SIDING 8'-0" ENTRY DOOR NOTE: ALL MATERIALS ARE FOR DESIGN INTENT ONLY AND MAY VARY PER BUILDER SPECIFICATION. 06 PAINTED TRIM, SMOOTH FINISH ARCHITECTURAL BRACKET 8'-0" GARAGE DOOR 08 EXTERIOR SCONCE LIGHT 09 10 SCREENED ELECTRICAL METERS, COORD. W/ CIVIL ENCLOSED FIRE RISER ROOM, COORD. W/ CIVIL 01 02 03 04 05 05 07 08 06 1 A-02 8-PLEX FRONT ELEVATION SCALE: 1/4" = 1'-0" 2 A-02 8-PLEX FRONT ELEVATION SCALE: 1/4" = 1'-0" 3 A-02 8-PLEX LEFT ELEVATION SCALE: 1/4" = 1'-0" 4 A-02 8-PLEX RIGHT ELEVATION SCALE: 1/4" = 1'-0" 09 10 8-PLEX FARMHOUSE ELEVATIONS A-02 Sheet Sheet Name Checked By: Drawn By: Date: REV. COMMENT DATE OL, SH OL, CVH, MM 02.05.2020 PRELIMINARY EAST RIDGE FIFTH FILING PDP SUBMITTAL www.dtjdesign.com DTJ DESIGN, Inc. 3101 Iris Avenue, Suite 130 Boulder, Colorado 80301 T 303.443.7533 FDP SUBMITTAL 1 FDP SUBMITTAL FIRST FLOOR - GROSS BUILDING AREA SECOND FLOOR - GROSS BUILDING AREA NOTE: ALL SQUARE FOOTAGES ARE MEASURED TO EXTERIOR EDGE OF FRAMING AND INCLUDE COVERED PATIO AND DECKS. TOTALS REPRESENT DESIGN INTENT ONLY AND ARE SUBJECT TO CHANGE. 7,846 SQ. FT. 6,855 SQ. FT. ELEVATION KEYNOTES 01 02 03 07 ASPHALT SHINGLE ROOF 04 05 HORIZONTAL SIDING, 7" REVEAL BOARD AND BATTEN SIDING STANDING SEAM METAL ROOF 8'-0" ENTRY DOOR HORIZONTAL SIDING, 4" REVEAL NOTE: ALL MATERIALS ARE FOR DESIGN INTENT ONLY AND MAY VARY PER BUILDER SPECIFICATION. 06 PAINTED TRIM, SMOOTH FINISH 08 8'-0" GARAGE DOOR DECORATIVE GABLE VENT 09 10 EXTERIOR SCONCE LIGHT 11 12 SCREENED ELECTRICAL METERS, COORD. W/ CIVIL ENCLOSED FIRE RISER ROOM, COORD. W/ CIVIL 01 02 04 03 05 06 06 07 05 07 05 02 08 09 10 10 Sheet Sheet Name Checked By: Drawn By: Date: REV. COMMENT DATE OL, SH OL, CVH, MM 02.05.2020 PRELIMINARY EAST RIDGE FIFTH FILING PDP SUBMITTAL www.dtjdesign.com DTJ DESIGN, Inc. 3101 Iris Avenue, Suite 130 Boulder, Colorado 80301 T 303.443.7533 11 12 8-PLEX FARMHOUSE ELEVATIONS A-01 FDP SUBMITTAL 1 FDP SUBMITTAL