HomeMy WebLinkAbout609 S COLLEGE AVE MIXED USE - BDR200004 - SUBMITTAL DOCUMENTS - ROUND 2 - LANDSCAPE PLANX X
X
X X X X X X
X
X X
X
X
X
X X
X
X
X
X X
C.O. G
W
C
S
E
VAULT
ELEC
TELE
T
VAULT
ELEC
VAULT
ELEC
/ / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
G G G
G
G
E
E E
E
E
E
E
CTV
CTV
CTV
X
X
G
G
G
G
OHU OHU
3 - PC2 (M)
GA - 1 JS (M) - 3
MRE - 6
3 - CK
BTA - 3
3 - CK
BTA - 3 CK - 6
HP - 5
5 - HP
20 SITE DEVELOPMENT
SYMBOL DESCRIPTION QTY
LOW HYDROZONE 106 SF
MEDIUM HYDROZONE 2,108 SF
HIGH HYRDOZONE 1,026 SF
*TYPE (PROPOSED & EXISTING TO REMAIN) COUNT 10-19 TREES > 50%
GINKGO BILOBA `AUTUMN GOLD` TM / AUTUMN
GOLD MAIDENHAIR TREE
1 10%
JUNIPERUS SCOPULORUM `SKYROCKET` /
SKYROCKET JUNIPER
3 30%
THUJA OCCIDENTALIS `EMERALD` / EMERALD
ARBORVITAE
3 30%
PRUNUS CERASIFERA `CRIMSON POINTE` /
`CRIMSON POINTE FLOWERING PLUM
3 30%
TOTAL TREES 10 100%
*CITY OF FORT COLLINS CODE SECTION 3.2.1(D)3
MINIMUM SPECIES DIVERSITY
PER CITY OF FORT COLLINS 3.2.1(D)3 PROPOSED PLAN MUST HAVE A SPECIES DIVERSITY OF
(10-19 TREES > 50%, 20-39 TREES > 33%, 40-59 TREES > 25%, 60+ TREES > 15%). OF THE 11 TOTAL
TREES SURVEYED AND PROPOSED ON SITE, NO SPECIES MAY HAVE MORE THAN 5 QUANTITY.
C.O. G
HIGH HYDROZONE
MEDIUM HYDROZONE
LOW HYDROZONE
EXISTING HOUSE
(TO BE REMODELED)
NEW ADDITION
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Andrew Papke-Larson Layout: 4 LANDSCAPE NOTES AND DETAILS Printed On: 7/1/2020 12:58 PM File Name: Landscape Plan.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
Sam Coutts
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
OWNER
LANDSCAPE ARCHITECT
South College 609 LLC
C.O. G
W
C
S
C
E
T
/ / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
G G
G
G
G
E
E
E
E
E
E
E
CTV
CTV
CTV CTV
CTV
X
X
G
G
G G
G
G
G
G
G
G
G
G
G G
OHU
OHU
VAULT
ELEC
CONTROL
IRR
VAULT
ELEC
TELE
VAULT
ELEC
C.O. G
W
C
S
E
VAULT
ELEC
TELE
T
VAULT
ELEC
VAULT
ELEC
/ / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / /
/ / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
G G
G
G
G
E
E E
E
E
E
E
CTV
CTV
CTV
X
X
G
G
G
G
OHU
OHU
IC VAULT & TELEPHONE POLE
EXISTING HOUSE
(TO BE REMODELED)
DALZELL ALLEY
(BRICK PAVERS)
APPROXIMATE PROPERTY BOUNDARY
#7
#6
#5
#4
#3
#2
#1
EXISTING TREE TO REMAIN
SOUTH
COLLEGE
AVE
EXISTING GAS UTILITY
EXISTING
NEIGHBORING WALK
EXISTING NEIGHBORING BUILDING
EXISTING
NEIGHBORING
ASPHALT PARKING
EXISTING NEIGHBORING BUILDING
EXISTING
NEIGHBORING
ASPHALT PARKING
EXISTING
STREET TREE
TO REMAIN
EXISTING
SHRUBS TO
BE REMOVED
EXISTING
SHRUB TO BE
REMOVED
19'-0" INTERIOR
CRITICAL ROOT ZONE
100-YR
FLOODPLAIN
IN (CITY OF FORT COLLINS)
7' OFF EXISTING
BUILDINGS
CTV
G
OHU
E
E
E
FENCE
EXISTING CABLE UTILITY
EXISTING GAS UTILITY
EXISTING OVERHEAD UTILITY
EXISTING ELECTRIC UTILITY
G
E
VAULT
ELEC EXISTING ELECTRIC VAULT & TELEPHONE POLE
EXISTING LIGHT POLE
C
100-YR FLOODPLAIN (CITY OF FORT COLLINS)
# TYPE DBH CONDITION MITIGATION TO BE
PRESERVED
MITIGATION TO BE
REMOVED REASON FOR REMOVAL / NOTES
1 BUR OAK 8" FAIR + 1.5
2 JUNIPER 23" FAIR 2.5 NEW ADDITION
3 BUCKTHRON 8" FAIR 1 NEW ADDITION
4 CRAB APPLE 17" FAIR - 1 NEW ADDITION, DBH MEASURED UNDER 4.5'
5 BLUE SPRUCE 27" FAIR + 4 NEW ADDITION
6 CRAB APPLE 24" POOR 0 NEW ADDITION, DBH MEASURED UNDER 4.5'
7 BUR OAK 38" FAIR + 5
TOTAL 5 9
TYPE COUNT REQUIRED MITIGATION TREES
TREES PRESERVED 2 0
TREES TO BE REMOVED 5 9
TOTAL 7 9
LOCATION COUNT
MITIGATION TREES PROPOSED TO BE PLANTED ON-SITE 9
MITIGATION TREES PROPOSED TO BE PLANTED OFF-SITE 0
PAYMENT IN LIEU (ASSUMES $450 PER TREE) 0
TOTAL 9
NOTE: MITIGATION TREE LOCATIONS ARE SHOWN ON THE SHEET 3 - LANDSCAPE PLAN
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Andrew Papke-Larson Layout: 5 TREE MITIGATION PLAN Printed On: 7/1/2020 12:58 PM File Name: Tree Mitigation.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
Sam Coutts
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
OWNER
South College 609 LLC
262 E. Mountain Ave.
Fort Collins, CO 80524
LANDSCAPE ARCHITECT
TREE MITIGATION
PLAN
BASIC DEVELOPMENT
REVIEW
609 SOUTH COLLEGE
02 BDR SUBMITTAL 07.08.2020
01 BDR SUBMITTAL 02.05.2020
FORT COLLINS, CO
SC
APL
R19-053
5
NORTH
0 05 10 20
SCALE: 1"=10'-0"
TREE MITIGATION LEGEND
EXISTING TREES TO
SAVE IN PLACE
XXX XXX
EXISTING TO BE REMOVED
LEGEND TREE PROTECTION NOTES TREE MITIGATION TABLE
TREE DIAMETER AT BREAST HEIGHT
(INCHES)
AUGER DISTANCE FROM FACE OF
TREE (FEET)
0-2 1
3-4 2
5-9 5
10-14 10
15-19 12
OVER 19 15
1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT SHALL REMAIN AND BE PROTECTED
UNLESS NOTED ON THESE PLANS FOR REMOVAL.
2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A
FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED
THE DISTURBANCE.
3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY
STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A
CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE.
4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED
EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN
HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR
ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR
MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE.
5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE
CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH
AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO
THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.
6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.
7. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING
EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT
SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE
AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM
TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW:
8. NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31)
WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE
BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT
SITE. THE SURVEY SHALL BE SENT TO THE CITY ENVIRONMENTAL PLANNER. IF ACTIVE NESTS ARE
FOUND, THE CITY WILL COORDINATE WITH RELEVANT STATE AND
FEDERAL REPRESENTATIVES TO DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL
AND CONSTRUCTION APPLY.
9. “WITHIN THE DRIPLINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A
FOUR-INCH DEPTH (WITH EXCEPTION TO THE PROPOSED BUILDING FOUNDATION) UNLESS A QUALIFIED
ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. IN THE EVENT THE
PROPOSED CUT/FILL IS NOT APPROVED, TECHNIQUES AND PRODUCTS SHALL BE RECOMMENDED BY
THE ARBORIST OR FORESTER TO MITIGATE THE IMPACT OF THE CUT/FILL WHILE ENABLING
CONSTRUCTION TO CONTINUE.”
TYPE MINIMUM SIZE
CANOPY SHADE TREE 2.0" CALIPER AND B&B OR EQUIVALENT
EVERGREEN TREE 8.0" HEIGHT AND B&B OR EQUIVALENT
ORNAMENTAL TREE 2.0" CALIPER AND B&B OR EQUIVALENT
MITIGATION SIZING CHART
TREE MITIGATION SUMMARY
PROVIDED TREE MITIGATION
262 E. Mountain Ave.
Fort Collins, CO 80524
LANDSCAPE NOTES
AND DETAILS
BASIC DEVELOPMENT
REVIEW
609 SOUTH COLLEGE
02 BDR SUBMITTAL 07.08.2020
01 BDR SUBMITTAL 02.05.2020
FORT COLLINS, CO
SC
APL
R19-053
4
1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD
APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OR
EQUIVALENT.
2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM.
THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING
PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS,
SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION
PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL.
3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS
REQUIRING REVEGETATION AND LANDSCAPING.
4. SOIL AMENDMENTS: THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE THOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN
EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY
TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF
LANDSCAPE AREA.
5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO
ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE
SECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR
PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE.
6. MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED
AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN
INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL
LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE
REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION.
7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF
THESE PLANS.
8. THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES:
40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS
15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS
10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES
6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES.
4 FEET BETWEEN SHRUBS AND PUBLIC WATER AND SANITARY AND STORM SEWER LINES
4 FEET BETWEEN TREES AND GAS LINES
9. ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a).
10. PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR
LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES
PROVIDED THAT THE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42"
IN HEIGHT AND OF AN OPEN DESIGN.
11. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE
REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS ASSOCIATION. THE PROPERTY OWNERS ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL
ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS.
12. LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS AND TRAFFIC CIRCLES ADJACENT TO RESIDENTIAL LOTS ARE REQUIRED TO BE MAINTAINED BY THE
PROPERTY OWNER OF THE RESIDENTIAL LOT, AND THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS.
13. THE DEVELOPER SHALL ENSURE THAT THE FINAL LANDSCAPE PLAN IS COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THE PROPOSED GRADING,
STORM DRAINAGE, AND OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS
ON THIS PLAN.
14. MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL
QUANTITY, QUALITY, AND DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THE
PLANT LIST, SPECIES AND QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST HAVE WRITTEN APPROVAL BY THE
CITY PRIOR TO INSTALLATION.
15. IRRIGATED TURF MIX SHALL BE VORTEX BLUEGRASS SOD BY KORBY SOD LLC.
GENERAL LANDSCAPE NOTES
PREVAILING WIND
PLAN VIEW - THREE STAKES
TREE PLANTING DETAIL - STEEL POSTS
SCALE: NTS
ROUND TOPPED SOIL BERM 4"
HIGH X 8" WIDE ABOVE ROOT
BALL SURFACE SHALL BE
CONSTRUCTED AROUND THE
ROOT BALL. BERM SHALL BEGIN
AT ROOT BALL PERIPHERY. (OMIT
IN TURF AREAS)
NOTES:
SET S0 THAT TOP OF ROOT 1-2"
HIGHER THAN FINISHED GRADE
MARK NORTH SIDE OF TREE IN
NURSERY AND ROTATE TREE TO
FACE NORTH AT THE SITE
WHENEVER POSSIBLE
2 STRAND 12 GAUGE GAL. WIRE
(TWIST TO TIGHTEN) &
GROMMETED NYLON STRAPS
STEEL T-POSTS DRIVEN (MIN. 24") FIRMLY INTO
UNDISTURBED SOIL OUTSIDE OF PLANTING
HOLE BEFORE BACKFILLING
STAKE ABOVE FIRST BRANCHES OR AS
NECESSARY FOR FIRM SUPPORT
BACKFILL WITH BLEND OF EXISTING SOIL
AND A MAXIMUM 20% (BY VOL.) ORGANIC
MATERIAL PLACE FIRMLY BUT DON'T TAMP
OR COMPACT AROUND ROOT BALL. WATER
WATER THOROUGHLY TO SETTLE AND
REMOVE AIR POCKETS. PRIOR TO
MULCHING, LIGHTLY TAMP SOIL AROUND
THE ROOT BALL IN 6" LIFTS TO BRACE
TREE. DO NOT OVER COMPACT. WHEN THE
PLANTING HOLE HAS BEEN BACKFILLED,
POUR WATER AROUND THE ROOT BALL TO
SETTLE THE SOIL.
REMOVE ALL WIRE, TWINE BURLAP, MESH
AND CONTAINERS FROM ENTIRE ROOT
BALL AND TRUNK
4" DEEP MULCH RING PLACED A MINIMUM
OF 6' IN DIAMETER. 1" MULCH OVER ROOT
BALL. DO NOT PLACE MULCH IN CONTACT
WITH TREE TRUNK
3 X BALL DIA.
BOTTOM OF ROOT BALL RESTS ON
EXISTING OR RECOMPACTED SOIL
SCARIFY SIDES OF HOLE LEAVING
1:1 SLOPE
1 L-PL-12
STAKING NOTES:
STAKE TREES PER FOLLOWING SCHEDULE, THEN REMOVE AT
END OF FIRST GROWING SEASON AS FOLLOWS:
1 1/2" CALIPER SIZE - MIN. 1 STAKE ON SIDE OF PREVAILING
WIND. (GENERALLY N.W. SIDE)
1 1/2" - 3" CALIPER SIZE - MIN. 2 STAKES - ONE ON N.W. SIDE,
ONE ON S.W. SIDE
3" CALIPER SIZE AND LARGER - 3 STAKES PER DIAGRAM
WIRE OR CABLE SHALL BE MIN. 12 GAUGE, TIGHTEN ONLY
ENOUGH TO KEEP FROM SLIPPING. ALLOW FOR SOME TRUNK
MOVEMENT. NYLON STRAPS SHALL BE LONG ENOUGH TO
ACCOMMODATE 1 1/2" OF GROWTH AND BUFFER ALL BRANCHES
FROM WIRE GUYING PLAN
PLANT SO THAT TOP OF ROOT BALL
IS 2" HIGHER THAN FINISHED GRADE
GROMMETED NYLON STRAPS
GALVANIZED WIRE TWIST TO TIGHTEN
6' STEEL T-POSTS (SEE SCHEDULE) DRIVEN
(MIN. 24") FIRMLY INTO UNDISTURBED SOIL
OUTSIDE ROOTBALL.
SCARIFY SIDES OF PLANTING HOLE
LEAVING 1:1 SLOPE
BACKFILL WITH BLEND OF EXISTING
SOIL AND A MAXIMUM 20% (BY
VOL.) ORGANIC MATERIAL TAMP
SOIL AROUND ROOT BALL W/ FOOT
PRESSURE SO THAT IT DOESN'T
SHIFT. WATER THOROUGHLY TO
SETTLE AND REMOVE AIR
POCKETS. PRIOR TO MULCHING,
LIGHTLY TAMP SOIL AROUND THE
ROOT BALL IN 6" LIFTS TO BRACE
TREE. DO NOT OVER COMPACT.
WHEN THE PLANTING HOLE HAS
BEEN BACKFILLED, POUR WATER
AROUND THE ROOT BALL TO
SETTLE THE SOIL.
PRUNING NOTES:
DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNE
ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS AND
BROKEN BRANCHES. SOME INTERIOR TWIGS AND
LATERAL BRANCHES MAY BE PRUNED. HOWEVER, DO
NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT
EXTEND TO THE EDGE OF THE CROWN
3 X BALL DIA.
PREVAILING WIND
4" DEEP MULCH RING PLACED A MINIMUM
OF 6' IN DIAMETER. DO NOT PLACE
MULCH IN CONTACT WITH TREE TRUNK
ROUND-TOPPED SOIL BERM 4" HIGH X 8"
WIDE ABOVE ROOT BALL SURFACE
SHALL BE CONSTRUCTED AROUND THE
ROOT BALL. BERM SHALL BEGIN AT
ROOT BALL PERIPHERY. (OMIT IN TURF
AREAS)
CONIFER TREE PLANTING DETAIL - STEEL POSTS
SCALE: NTS
REMOVE ALL WIRE, TWINE BURLAP,
MESH AND CONTAINERS FROM
ENTIRE ROOT BALL AND TRUNK
2 L-PL-13
PRUNING NOTES:
DO NOT HEAVILY PRUNE SHRUB AT PLANTING.
PRUNE ONLY DEAD OR BROKEN BRANCHES. IF
FORM IS COMPROMISED BY PRUNING,
REPLACE SHRUB
PLACEMENT NOTES:
SET SHRUB PLUMB. SPACE PLANTS, AND
PLACE FOR BEST EFFECT
SET TOP OF ROOTBALL 1-2" HIGHER THAN
ADJACENT GRADE
SCARIFY SIDES AND USE 1:1 SLOPE
4" DEEP MULCH RING 3' IN DIA. PLACE ON
GEOTEXTILE WEED BARRIER. 1" OF MULCH ON
TOP OF ROOT BALL
REMOVE CONTAINER (INCLUDING FIBER
CONTAINERS), BASKETS, WIRE, ETC. FROM THE
ROOT BALL. BREAK UP ENCIRCLING ROOTS
WITH SHARP KNIFE OR SPADE. SPLIT BOTTOM
OF ROOT BALL. PLACE ON UNDISTURBED SOIL
TO PREVENT SETTLEMENT. PRIOR TO
MULCHING, LIGHTLY TAMP SOIL AROUND THE
ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO
NOT OVER COMPACT. WHEN THE PLANTING
HOLE HAS BEEN BACKFILLED, POUR WATER
AROUND THE ROOT BALL TO SETTLE THE SOIL.
BACKFILL WITH BLEND OF EXISTING SOIL
AND A MAX. 20% (BY VOL.) ORGANIC
MATERIAL. WATER THOROUGHLY TO
SETTLE AND REMOVE AIR POCKETS
2 X BALL DIA.
4" HIGH WATER SAUCER
SHRUB PLANTING DETAIL
3 SCALE: NTS L-PL-14
ORNAMENTAL GRASS DETAIL
NO SCALE
SPECIFIED MULCH AT 3" DEPTH (SEE
LANDSCAPE PLANS)
REMOVE CONTAINER AND
4" MIN. HAND-LOOSEN ROOTS TYP.
BACKFILL WITH BLEND OF EXISTING
SOIL AND A MAX. 30% (BY VOL.)
ORGANIC MATERIAL. WATER
THOROUGHLY TO SETTLE AND
REMOVE AIR POCKETS
PLACEMENT NOTES:
SET PLANT PLUMB. SPACE PLANTS IN
OFFSET TRIANGULAR PATTERN AND
PER PLANTING PLAN
SET TOP OF ROOTBALL AT TOP OF
AMENDED SOIL BASE IN WELL DRAIN
SOIL OR 1" HIGHER THAN ADJACENT
GRADE IF SOIL IS HEAVY CLAY MIX
3 OP-KAY-04
HYDROZONE AREA (SF) WATER NEEDED
(GALLONS/SF)
ANNUAL WATER USE
(GALLONS)
HIGH 1,026 18
18,468.00
MODERATE
2,108 10
21,080.00
LOW 106
3
318.00
VERY LOW 0
0
0.00
TOTAL 3,240
12.3043
39,866
ANNUAL WATER USE NOT TO EXCEED 15 GAL./SF. AVERAGE OVER THE SITE
TREE SPECIES DIVERSITY
WATER USE TABLE
HYDROZONE PLAN HYDROZONE SCHEDULE
NORTH
0 10 20 40
SCALE: 1"=20'-0"
7 - MRE
3 - PB MRE - 3
PVS - 3
BGB - 3
3 - CIN
4 - EUK
5 - PRO
IGE - 8
3 - TE (M)
3 - BTA
17 - CK
CK - 5
10 - CK
BTA - 3
CK - 4
CC2 - 4
AD - 10
PFY - 1
PVS - 3
IPV - 7
3 - AP
9 - HR 15 - KC
7 - AD
11 - HR
9 - AD
3 - DB
1 - PD
3 - MZ
G
G
G
G
C
CONTROL
IRR
W W W W
WS
WS
G
G
G
G
F
NEW ADDITION EXISTING HOUSE
DALZELL ALLEY (TO BE REMODELED)
(BRICK PAVERS)
3 PARKING
SPACES
EXISTING BUILDING
LAWN
GRASS CRETE /
POTENTIAL PARKING SPACE
FENCE
EXISTING GARAGE
NEIGHBORING TRASH
ENCLOSURE
NEIGHBORING
TRASH
ENCLOSURE
SIDEWALK
VEHICLE
GATE
ENTRY GATE
EXISTING SEWER
MANHOLE
EXISTING SIDEWALK
TO REMAIN
EXISTING SIDEWALK
TO REMAIN
EXISTING PATIO
EXISTING FENCE
EXISTING PLANTER WALL
ON ADJACENT PROPERTY
BRICK PATIO
APPROXIMATE PROPERTY BOUNDARY
EXISTING PLANTER WALL
ON ADJACENT PROPERTY
EDGE OF NEIGHBORS
EXISTING ASPHALT
EDGE OF NEIGHBORS
EXISTING ASPHALT
TRASH ENCLOSURE
DRAIN PAN EXISTING WALK
(COBBLE INSET IN PAN)
RISERS
TO PATIO
EXISTING STREET
TREE TO REMAIN
SOUTH
COLLEGE AVE
BENCH
FIRE PIT
EXISTING BUILDING
100-YR FLOODPLAIN
EXISTING TREE
TO REMAIN
BOULDER
TRANSFORMER
BIKE
RACKS
RAIN
19'-0" INTERIOR GARDEN
CRITICAL ROOT ZONE
100-YR FLOODPLAIN
PERSON
GATE
EXISTING WATER METER
FIRE UTILITY LINE, RE: CIVIL
SAW CUT LINE,
RE: CIVIL
WATER UTILITY LINE, RE: CIVIL
CTV
G
OHU
E
G
CTV
X
C
CONTROL
IRR
W
WS
E
EXISTING CABLE UTILITY
EXISTING GAS UTILITY
EXISTING OVERHEAD UTILITY
EXISTING ELECTRIC UTILITY
G
E
VAULT
ELEC EXISTING ELECTRIC VAULT &
TELEPHONE POLE
EXISTING LIGHT POLE
C
100-YR FLOODPLAIN
(CITY OF FORT COLLINS)
EXISTING TREE TO REMAIN
PROPERTY BOUNDARY
PROPOSED CABLE UTILITY
PROPOSED GAS UTILITY
PROPOSED FENCE
PROPOSED CABLE UTILITY BOX
PROPOSED IRRIGATION CONTROL
PROPOSED CONTOUR
PROPOSED FIRE UTILITY
PROPOSED WATER UTILITY
PROPOSED EASMENT
PROPOSED ELECTRIC UTILITY
02 LANDSCAPE MATERIAL
SYMBOL DESCRIPTION
WOOD MULCH
IRRIGATED TURF
RIVER COBBLE
PEA GRAVEL
CRUSHER FINES
CANOPY TREES QTY BOTANICAL / COMMON NAME CONT CAL SIZE
GA 1 GINKGO BILOBA `AUTUMN GOLD` TM / AUTUMN GOLD MAIDENHAIR TREE B & B 2"CAL
EVERGREEN TREES QTY BOTANICAL / COMMON NAME CONT CAL SIZE
JS (M) 3 JUNIPERUS SCOPULORUM `SKYROCKET` / SKYROCKET JUNIPER B & B 8`HT
TE (M) 3 THUJA OCCIDENTALIS `EMERALD` / EMERALD ARBORVITAE B & B 8`HT
ORNAMENTAL TREES QTY BOTANICAL / COMMON NAME CONT CAL SIZE
PC2 (M) 3 PRUNUS CERASIFERA `CRIMSON POINTE` / `CRIMSON POINTE FLOWERING PLUM B & B 2.5"CAL
SHRUBS QTY BOTANICAL / COMMON NAME SIZE
AP 3 ARCTOSTAPHYLOS X COLORADOENSIS `PANCHITO` / PANCHITO MANZANITA 5 GAL
BTA 14 BERBERIS THUNBERGII `CRIMSON PYGMY` / CRIMSON PYGMY BARBERRY 5 GAL
CC2 4 CARYOPTERIS X CLANDONENSIS `BLUE MIST` / BLUE MIST SHRUB 5 GAL
DB 3 DAPHNE X BURKWOODII `CAROL MACKIE` / CAROL MACKIE DAPHNE 5 GAL
HP 10 HESPERALOE PARVIFLORA / RED YUCCA 5 GAL
MRE 16 MAHONIA REPENS / CREEPING COLORADO HOLLY 5 GAL
PD 1 PHYSOCARPUS OPULIFOLIUS `DIABOLO` / DIABLO NINEBARK 5 GAL
PB 3 PINUS STROBUS `BLUE SHAG` / BLUE SHAG WHITE PINE 5 GAL
PFY 1 POTENTILLA FRUTICOSA `YELLOW GEM` / YELLOW GEM POTENTILLA 5 GAL
ORNAMENTAL GRASSES QTY BOTANICAL / COMMON NAME SIZE
BGB 3 BOUTELOUA GRACILIS `BLONDE AMBITION` / BLUE GRAMA 1 GAL
CK 48 CALAMAGROSTIS X ACUTIFLORA `KARL FOERSTER` / FEATHER REED GRASS 1 GAL
MZ 3 MISCANTHUS SINENSIS `ZEBRINUS` / ZEBRA GRASS 3 GAL
PVS 6 PANICUM VIRGATUM `SHENENDOAH` / BURGUNDY SWITCH GRASS 1 GAL
PERENNIALS QTY BOTANICAL / COMMON NAME SIZE
AD 26 AQUILEGIA CHRYSANTHA `DENVER GOLD` / YELLOW COLUMBINE 1 GAL
CIN 3 CALLIRHOE INVOLUCRATA / PURPLE POPPYMALLOW 1 GAL
EUK 4 ERIOGONUM UMBELLATUM `KANNAH CREEK` / KANNAH CREEK SULPHUR FLOWER 1 GAL
HR 20 HEUCHERA PULCHELLA / SANDIA MOUNTAIN CORAL BELLS 1 GAL
IGE 8 IRIS GERMANICA / GERMAN IRIS 1 GAL
IPV 7 IRIS PALLIDA `VARIEGATA` / VARIEGATED SWEET IRIS 1 GAL
KC 15 KNIPHOFIA CAULESCENS / BLUE LEAF FIRE POKER 1 GAL
PRO 5 PENSTEMON ROSTRIFLORUS / BRIDGE PENSTEMON 1 GAL
1
4 TON (1.5'X2') SANDSTONE BOULDER
1
2 TON (2'X3') SANDSTONE BOULDER
3
4 - 1 TON (2'X4') SANDSTONE BOULDER
NOTE: BURY MIN. 1/4 BOULDER
HEIGHT BELOW SURFACE.
DRAWING NUMBER:
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
■ land planning ■ landscape architecture ■
■ urban design ■ entitlement ■
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No. DESCRIPTION DATE
REVISIONS
No. DESCRIPTION DATE
Plotted By: Andrew Papke-Larson Layout: 3 LANDSCAPE PLAN Printed On: 7/1/2020 12:58 PM File Name: Landscape Plan.dwg
ORIGINAL SIZE 24X36
ENTITLEMENT
DRAWINGS
NOT FOR
CONSTRUCTION
RIPLEY DESIGN INC.
Sam Coutts
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
OWNER
LANDSCAPE ARCHITECT
South College 609 LLC
262 E. Mountain Ave.
Fort Collins, CO 80524
LANDSCAPE PLAN
BASIC DEVELOPMENT
REVIEW
609 SOUTH COLLEGE
02 BDR SUBMITTAL 07.08.2020
01 BDR SUBMITTAL 02.05.2020
FORT COLLINS, CO
SC
APL
R19-053
0 05 10 20
SCALE: 1"=10'-0"
3
NORTH
LEGEND REFERENCE NOTES SCHEDULE PLANT SCHEDULE
BOULDER LEGEND
NOTES: TREES NOTED ON THE LANDSCAPE PLAN AND IN PLANT SCHEDULE WITH AN (M) ARE MITIGATION TREES