Loading...
HomeMy WebLinkAbout609 S COLLEGE AVE MIXED USE - BDR200004 - SUBMITTAL DOCUMENTS - ROUND 2 - STORMWATER-RELATED DOCUMENTSDrainage Memo July 8, 2020 Project: 609 South College Avenue Project No. 564-005 Attn: Stormwater Staff City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, CO 80521 Stormwater Staff: This letter serves to document the proposed drainage impacts of the addition to the existing building proposed at 609 South College Avenue in Fort Collins, Colorado. Project Overview The project proposes to add an addition to the rear (west side) of the existing building adding ~800 sf. Construction activities will also include the removal of the existing garage. A concrete patio area, concrete walks, and alley parking will also be added as a part of these improvements, as well as a rain garden similar to what was used at the Music District to provide LID treatment to the site. A dedicated fire service and a single-phase transformer will also be added as part of this project. Existing Site The existing site is relatively flat (0% - 1%) in the front and rear yards, and functions as an “A” Lot, with drainage generally draining from back to front along the side lot lines. In addition to the existing home, the lot consists of a garage, a concrete driveway, concrete entry walk, and concrete walks around the entire home. The remainder of the site is Kentucky Bluegrass lawn, with small landscaping beds and mature trees. The total existing impervious area for the lot is 2,781 sf. Proposed Site The proposed site will generally maintain the existing site drainage. Drainage from the rear yard, patio area, and roof will be directed overland via concrete pan along the southern lot line to a rain garden that will provide LID treatment. In the event of a large storm, water will exit out to College Avenue through a proposed sidewalk chase. The parking area will maintain the existing drainage pattern and flow west to Dalzell Alley. Existing grades outside of our improvements will remain unchanged, including along the north side of the existing house where no improvements are proposed. The total proposed impervious area for the lot is 4,725 sf. The proposed change in imperviousness will add an estimated 0.46 cfs to College Avenue and 0.1 cfs to Dalzell Alley in a 100-yr event. We do not foresee the additional runoff causing any issues with the existing inlets intercepting the flow at Myrtle Street and College Avenue, but additional information regarding the inlet’s capacity will need to be obtained from the City and verified. No adverse effects to adjacent properties are anticipated due to the increased imperviousness of the site. Detention Since the impervious area increase is than the 5,000 sf allowed in the Old Town Master Drainage Basin, no detention is required for the site. Floodplain The property is not located in a FEMA regulated flood hazard zone. The project site is, however, located partially within the City of Fort Collins regulated West Myrtle Street floodplain, which is part of a larger basin study, the Old Town Basin, as shown in Figure 1, below. A LOMA (Letter of Map Amendment) is proposed with the site, based on existing elevation data obtained with recent survey work conducted for the project. The LOMA will be submitted by separate document, and is anticipated to show, based on existing ground elevations that the current project site is in fact elevated above current Base (100-year) Flood Elevation. Current floodplain mapping of the area has been recently revised by the City of Fort Collins. The original Old Town Basin study was entitled, “Old Town Basin Master Drainage Plan”, which was conducted by Anderson Consulting Engineers in May of 2002. We have been in discussion City Staff, and have been directed by Staff to utilize current draft information as best available data. The question of inadvertent detention has been discussed, and initially, it was thought that compensatory storage may be necessary with any fill placed within the development site. However, per correspondence with City Staff, this area is not within the inadvertent detention ponding area, which was referred to as the “College and Mulberry Pond”. Per City Staff, based on recent updated 2D modeling, the Base Flood Elevation (BFE) for this site is 4995.50 (NAVD 88). Figure 1 – Current City of Fort Collins Floodplain Mapping (Source: FCMaps, http://gisweb.fcgov.com) Control points/benchmarks utilized with the survey completed for the project are as per the plan set for the project and are shown in Figure 2, below. Figure 2 – Current City of Fort Collins Floodplain Mapping (Source: Utility Plans for 609 South College Avenue, Northern Engineering) It is noted that some of the surrounding developments have used the NGVD 29 (unadjusted) datum. The conversion from NAVD 88 to NGVD 29 (unadjusted) datum in this area is -3.18-ft. Any portion of the site to be developed outside of the LOMA area must comply with all floodplain regulations outlined in Chapter 10 of City Code. A floodplain use permit would be required for any site construction element (detention ponds, bike paths, parking lots, utilities, etc.) that may still remain in the floodplain once the LOMA is complete. It is also noted that Critical Facilities are not allowed in the floodplain. The applicant acknowledges that the building design does not comply with the current regulatory floodplain. The applicant will apply for a Letter of Map Amendment showing that the addition area is elevated above the Base Flood Elevation, however the City cannot guarantee approval of the LOMA without a submittal. The applicant understands that building permits cannot be issued prior to the approval of the LOMA. Water Quality and LID Water Quality for the site is being provided by the Udall Natural Area. LID treatment requirements will be achieved by directing the concentrated flows from the roof and the patio through concrete pan on the south side of the site into a rain garden in the front of the house. The rain garden will contain Bioretention Soil and landscape. Water will infiltrate the soil, removing stormwater contaminates. Due to the limited area available for the rain garden, it is only sized to handle the required run-on area of new or modified impervious area (%75), though a majority of the new and modified impervious area flows into the rain garden. It is assumed that this will not be a problem as the water flowing to the rain garden is not expected to be heavily contaminated. As an extra measure of protection, a cobble sediment basin will be added before the rain garden to further remove contaminates. In the event of a large storm, a sidewalk chase will allow rain garden overflow to travel to College Avenue. An exhibit has been provided to illustrate the existing and proposed impervious areas. Please feel free to contact us if you have any questions. Northern Engineering Services, Inc. Benjamin Ruch, PE Project Engineer CHARACTER OF SURFACE: Runoff Coefficient 1 Percentage Impervious 1 Project: Streets, Parking Lots, Roofs, Alleys, and Drives: Calculations By: Asphalt …………………......................... ............................................................................... 0.95 100% Date: Concrete ………………. ......................... ............................................................................... 0.95 100% Gravel (packed) ………. ......................... ............................................................................... 0.50 40% Roofs………………….. ......................... ............................................................................... 0.95 90% Pavers…………………. ......................... ............................................................................... 0.50 40% Recycled Asphalt ......................... ............................................................................... 0.80 80% Lawns and Landscaping Playgrounds 25% Sandy Soil Flat <2% ………….. ......................... ............................................................................... 0.10 2% Average 2% to 7% ......................... ............................................................................... 0.15 2% Steep >7% ………… ......................... ............................................................................... 0.20 2% Clayey Soil Flat <2% ………….. ......................... ............................................................................... 0.20 2% Average 2% to 7% ......................... ............................................................................... 0.25 2% Steep >7% ………… ......................... ............................................................................... 0.35 2% 2-year Cf = 1.00 10-year Cf = 1.00 USDA SOIL TYPE: C Sub-Basin ID Sub-Basin Area (sq. ft.) Sub-Basin Area (ac.) Area of Asphalt & Concrete (ac.) Area of Roofs (ac.) Area of Gravel (ac.) Area of Landscaping (ac) 2-year Composite Runoff Coefficient 10-year Composite Runoff Coefficient 100-year Composite Runoff Coefficient Composite % Imperv. Existing A 6,085 0.140 0.014 0.025 0.000 0.101 0.25 0.25 0.31 28% Existing B 488 0.011 0.002 0.000 0.000 0.009 0.25 0.25 0.31 20% CHARACTER OF SURFACE: Runoff Coefficient 1 Percentage Impervious 1 Project: Streets, Parking Lots, Roofs, Alleys, and Drives: Calculations By: Asphalt ………………… ......................... ............................................................................. 0.95 100% Date: Concrete ………………. ......................... ............................................................................. 0.95 100% Gravel (packed) ………. ......................... ............................................................................. 0.50 40% Roofs………………….. ......................... ............................................................................. 0.95 90% Pavers…………………. ......................... ............................................................................. 0.50 40% Recycled Asphalt ......................... ............................................................................. 0.80 80% Lawns and Landscaping Playgrounds 25% Sandy Soil Flat <2% ………….. ......................... ............................................................................. 0.10 2% Average 2% to 7% ......................... ............................................................................. 0.15 2% Steep >7% ………… ......................... ............................................................................. 0.20 2% Clayey Soil Flat <2% ………….. ......................... ............................................................................. 0.20 2% Average 2% to 7% ......................... ............................................................................. 0.25 2% Steep >7% ………… ......................... ............................................................................. 0.35 2% 2-year Cf = 1.00 10-year Cf = 1.00 USDA SOIL TYPE: C Sub-Basin ID Sub-Basin Area (sq. ft.) Sub-Basin Area (ac.) Area of Asphalt & Concrete (ac.) Area of Roofs (ac.) Area of Pavers (ac.) Area of Landscaping (ac) 2-year Composite Runoff Coefficient 10-year Composite Runoff Coefficient 100-year Composite Runoff Coefficient Composite % Imperv. Proposed A 6,206 0.14 0.038 0.038 0.005 0.062 0.55 0.55 0.69 53% Proposed B 824 0.02 0.016 0.000 0.000 0.003 0.55 0.55 0.69 84% Proposed OS1 1,139 0.03 0.002 0.012 0.000 0.013 0.60 0.60 0.75 47% PROPOSED COMPOSITE % IMPERVIOUSNESS AND RUNOFF COEFFICIENT CALCULATIONS 609 S. College Avenue B. Ruch Project: 609 S. College Avenue Calculations By: Date: Is Length >500' ? C*Cf (2-yr Cf=1.00) C*Cf (10-yr Cf=1.00) C*Cf (100-yr Cf=1.25) Ti 2-yr (min) Ti 10-yr (min) Ti 100-yr (min) Velocity, V (ft/s) Tt (min) 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) Existing A Existing A No 0.25 0.25 0.31 22.1 22.1 20.5 N/A N/A 22.1 22.1 20.5 Existing B Existing B No 0.25 0.25 0.31 5.9 5.9 5.5 N/A N/A 5.9 5.9 5.5 Existing OS Existing OS No 0.25 0.25 0.31 1.9 1.9 1.8 N/A N/A 5.0 5.0 5.0 EXISTING TIMES OF CONCENTRATION COMPUTATIONS B. Ruch July 1, 2020 Design Point Sub-Basin Overland Flow Gutter/Swale Flow Time of Concentration Velocity (Gutter Flow), V = 20·S½ Tt = L / 60V Tc = Ti + Tt (Equation RO-2) Velocity (Swale Flow), V = 15·S½ NOTE: C-value for overland flows over grassy surfaces; C = 0.25 Overland Flow, Time of Concentration: Gutter/Swale Flow, Time of Concentration: (Equation RO-4) ( ) 3 1 1 . 87 1 . 1 * S Project: 609 S. College Avenue Calculations By: Date: Is Length >500' ? C*Cf (2-yr Cf=1.00) C*Cf (10-yr Cf=1.00) C*Cf (100-yr Cf=1.25) Ti 2-yr (min) Ti 10-yr (min) Ti 100-yr (min) Velocity, V (ft/s) Tt (min) 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) Proposed A Proposed A No 0.25 0.25 0.31 12.0 12.0 11.1 1.87 1.2 13.2 13.2 12.3 Proposed B Proposed B No 0.35 0.35 0.44 6.1 6.1 5.4 N/A N/A 6.1 6.1 5.4 Proposed OS1 Proposed OS1 No 0.00 0.00 0.00 2.6 2.6 2.6 N/A N/A 5.0 5.0 5.0 Tt = L / 60V PROPOSED TIME OF CONCENTRATION COMPUTATIONS Overland Flow, Time of Concentration: B. Ruch July 1, 2020 Gutter/Swale Flow, Time of Concentration: Tc = Ti + Tt (Equation RO-2) Velocity (Gutter Flow), V = 20·S½ Velocity (Swale Flow), V = 15·S½ NOTE: C-value for overland flows over grassy surfaces; C = 0.25 Design Point Sub-Basin Overland Flow Gutter Flow Time of Concentration (Equation RO-4) ( ) 3 1 1 . 87 1 . 1 * S Project: Calculations By: Date: Existing A Existing A 0.14 22 22 21 0.25 0.25 0.31 1.53 2.61 5.53 0.05 0.09 0.24 Existing B Existing B 0.01 6 6 5 0.25 0.25 0.31 2.76 4.72 9.95 0.01 0.01 0.03 Existing OS Existing OS 0.04 5 5 5 0.25 0.25 0.31 2.85 4.87 9.95 0.03 0.04 0.11 Rainfall Intensity: EXISTING RUNOFF COMPUTATIONS Rational Method Equation: 609 S. College Avenue B. Ruch July 1, 2020 Flow, Q100 (cfs) Rainfall Intensity taken from the Fort Collins Stormwater Criteria Manual (FCSCM), Tables RA-7 and RA-8 Design Point Sub-Basin(s) Area, A (acres) 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) C2 C10 C100 Intensity, i2 (in/hr) Intensity, i10 (in/hr) Intensity, i100 (in/hr) Flow, Q2 (cfs) Flow, Q10 (cfs) Q = C f ( C )( i )( A ) Project: Calculations By: Date: Proposed A Proposed A 0.14 13 13 12 0.55 0.55 0.69 1.98 3.39 7.16 0.16 0.27 0.70 Proposed B Proposed B 0.02 6 6 5 0.55 0.55 0.69 2.67 4.56 9.95 0.03 0.05 0.13 Proposed OS1 Proposed OS1 0.03 5 5 5 0.60 0.60 0.75 2.85 4.87 9.95 0.04 0.08 0.20 July 1, 2020 Intensity, i10 (in/hr) C10 Area, A (acres) Intensity, i2 (in/hr) 100-yr Tc (min) B. Ruch 609 S. College Avenue PROPOSED RUNOFF COMPUTATIONS C100 Design Point Flow, Q100 (cfs) Flow, Q2 (cfs) 10-yr Tc (min) 2-yr Tc (min) C2 Flow, Q10 (cfs) Intensity, i100 (in/hr) Sub-Basin(s) Rational Method Equation: Rainfall Intensity: Rainfall Intensity taken from the Fort Collins Stormwater Criteria Manual (FCSCM), Tables RA-7 and RA-8 Q = C f ( C )( i )( A ) C.O. G W C S E VAULT ELEC TELE T VAULT ELEC CONTROL IRR VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X E E E W 605 COLLEGE LTD 605 S COLLEGE AVE FORT COLLINS, CO 805243003 GATON III INC DBA CANINOS ITALIAN RESTAURANT 613 S COLLEGE AVE FORT COLLINS, CO 805243003 SOUTH COLLEGE AVENUE DALZELL ALLEY EXISTING 100-YR FLOODPLAIN (CITY OF FORT COLLINS) EX A 0.140 ac EX A EX B EX OS EX OS 0.037 ac EX B 0.011 ac HISTORIC DRAINAGE EXHIBIT FORT COLLINS, CO 609 S. COLLEGE E NGINEER ING N O R T H E RN JULY 8, 2020 P:\564-005\DWG\DRNG\564-005_EXST DRNG.DWG ( IN FEET ) 0 1 INCH = 20 FEET 20 20 DRAINAGE SUMMARY TABLE DESIGN POINT BASIN ID TOTAL AREA (acres) C.O. G W C S E VAULT ELEC TELE T VAULT ELEC VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / E E E X E E E W X X X X X X X X X X A 0.142 ac A OS B OS 0.026 ac B 0.019 ac 605 COLLEGE LTD 605 S COLLEGE AVE FORT COLLINS, CO 805243003 GATON III INC DBA CANINOS ITALIAN RESTAURANT 613 S COLLEGE AVE FORT COLLINS, CO 805243003 SOUTH COLLEGE AVENUE DALZELL ALLEY EXISTING 100-YR FLOODPLAIN (CITY OF FORT COLLINS) PROPOSED DRAINAGE EXHIBIT FORT COLLINS, CO 609 S. COLLEGE E NGINEER ING N O R T H E RN JULY 8, 2020 P:\564-005\DWG\DRNG\564-005_DRNG.DWG ( IN FEET ) 0 XS#:1205 4990.5ft NGVD 29 XS#:1364 4990ft NGVD 29 XS#:1699 4992.8ft NGVD 29 XS#:1529 4992.5ft NGVD 29 XS#:1882 4993.7ft NGVD 29 XS#:1929 4992.3ft NGVD 29 S COLLEGE AVE W MYRTLE ST DALZELL ALY E MYRTLE ST CORBIN ALY . Printed: 11/07/2019 All floodplain boundaries are approximate. This information is based on the Federal Emergency Management Agency (FEMA) Flood Insurance Rate Map (FIRM) and the City of Fort Collins Master Drainageway Plans. This letter does not imply that the referenced property will or will not be free from flooding or damage. A property not in the Special Flood Hazard Area or in a City Designated Floodplain may be damaged by a flood greater than that predicted on the map or from a local drainage problem not shown on the map. This map does not create liability on the part of the City, or any officer or employee thereof, for any damage that results from reliance on this information. City Flood Risk Map Moderate Risk May include: - Areas of FEMA 500-year floodplain (FEMA Zone X-shaded). - Areas of FEMA or City 100-year floodplain (sheet flow) with average depths of less than 1 foot. - Areas protected by levees from the 100-year flood. Low Risk Areas outside of FEMA and City mapped 100-year and 500-year floodplains. Local drainage problems may still exist. City Flood Fringe - May Include: - Areas of FEMA 100-year floodplain (FEMA Zones A, AE, AO, and AH) - Areas of City 100-year floodplain including ponding areas and sheet flow areas with average depths of 1-3 feet. There is a 1% annual chance that these areas will be flooded. High Risk City Floodway - Area of 100-year floodplain with greatest depths and fastest velocities. 0 20 40 80 120 160 Feet C.O. G W C S C E VAULT ELEC TELE T VAULT ELEC CONTROL IRR VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / G G E E W SOUTH COLLEGE AVENUE DALZELL ALLEY X X X X X X C.O. G W C S E VAULT ELEC TELE T VAULT ELEC VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / E E W SOUTH COLLEGE AVENUE DALZELL ALLEY ROOFTOP CONCRETE ASPHALT PAVERS SURFACE AREA (SF) % IMPERV. IMPERV. AREA (SF) 1,928 C.O. G E VAULT ELEC VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X OHU E E E X X X X X X X X X X RAIN GARDEN REQUIRED VOLUME: 81 CU. FT. (TO TREAT NEW AND MODIFIED IMPERVIOUS AREA) PROVIDED VOLUME: 83 CU. FT. COBBLE SEDIMENT BASIN P:\564-005\DWG\DRNG\564-005_LID.DWG 609 S. COLLEGE AVE. FORT COLLINS COLORADO 301 N. Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com DESCRIPTION LID TREATMENT EXHIBIT DRAWN BY B. RUCH DATE JULY 8, 2020 PROJECT 564-005 LID-1 SCALE DRAWING 1"=20' ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 LEGEND RAIN GARDEN TREATMENT AREA RAIN GARDEN UNTREATED AREA 609 S. College Ave. Project Summary Total Proposed Impervious Area 4,725 sf Existing Impervious Area 2,781 sf Unmodified Existing Impervious Area (Roof and Walks) 1,505 sf New Impervious Area 1,944 sf New and Modified Impervious Area 3,220 sf Sheet 1 of 2 Designer: Company: Date: Project: Location: 1. Basin Storage Volume A) Effective Imperviousness of Tributary Area, Ia Ia = 100.0 % (100% if all paved and roofed areas upstream of rain garden) B) Tributary Area's Imperviousness Ratio (i = Ia/100) i = 1.000 C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV = 0.40 watershed inches (WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i) D) Contributing Watershed Area (including rain garden area) Area = 2,415 sq ft E) Water Quality Capture Volume (WQCV) Design Volume VWQCV = 81 cu ft Vol = (WQCV / 12) * Area F) For Watersheds Outside of the Denver Region, Depth of d6 = in Average Runoff Producing Storm G) For Watersheds Outside of the Denver Region, VWQCV OTHER = cu ft Water Quality Capture Volume (WQCV) Design Volume H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER = cu ft (Only if a different WQCV Design Volume is desired) 2. Basin Geometry A) WQCV Depth (12-inch maximum) DWQCV = 8 in B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical) Z = 4.00 ft / ft (Use "0" if rain garden has vertical walls) C) Mimimum Flat Surface Area AMin = 48 sq ft D) Actual Flat Surface Area AActual = 50 sq ft E) Area at Design Depth (Top Surface Area) ATop = 199 sq ft F) Rain Garden Total Volume VT= 83 cu ft (VT= ((ATop + AActual) / 2) * Depth) 3. Growing Media 4. Underdrain System A) Are underdrains provided? B) Underdrain system orifice diameter for 12 hour drain time i) Distance From Lowest Elevation of the Storage y = N/A ft Volume to the Center of the Orifice ii) Volume to Drain in 12 Hours Vol12 = N/A cu ft iii) Orifice Diameter, 3/8" Minimum DO = N/A in Design Procedure Form: Rain Garden (RG) Benjamin Ruch Northern Engineering June 30, 2020 609 S. College Fort Collins, CO UD-BMP (Version 3.06, November 2016) Choose One Choose One 18" Rain Garden Growing Media Other (Explain): YES NO RG_UD-BMP_v3.06.xlsm, RG 6/30/2020, 3:41 PM Sheet 2 of 2 Designer: Company: Date: Project: Location: 5. Impermeable Geomembrane Liner and Geotextile Separator Fabric A) Is an impermeable liner provided due to proximity of structures or groundwater contamination? 6. Inlet / Outlet Control A) Inlet Control 7. Vegetation 8. Irrigation A) Will the rain garden be irrigated? Notes: Design Procedure Form: Rain Garden (RG) Benjamin Ruch Northern Engineering June 30, 2020 609 S. College Fort Collins, CO Choose One Choose One Choose One Sheet Flow- No Energy Dissipation Required Concentrated Flow- Energy Dissipation Provided Plantings Seed (Plan for frequent weed control) Sand Grown or Other High Infiltration Sod Choose One YES NO YES NO RG_UD-BMP_v3.06.xlsm, RG 6/30/2020, 3:41 PM Target Treatment Percentage New and Modified Impervious Area 75% Minimum Area to be Treated by LID measures 2,415 sf Rain Garden Total Rain Garden Run on Area (Existing and New/Modified Impervious Area)** 3,464 sf **Rain Garden only sized to treat required impervious area (2,415 sf). Total Treatment Area 2,415 sf New and Modified Impervious Area Treatment Percentage** 75% Percent Total Project Immpervious Area Treated** 73.3% **Rain Garden only sized to treat 75% new and modified impervious area (2,415 sf). ** WATER QUALITY FOR ENTIRE SITE PROVIDED BY UDALL NATURAL AREA 853 0 0 100% 100% 100% 40% 86 TOTALS 2,781 TOTAL= 2,781 ROOFTOP CONCRETE ASPHALT PAVERS SURFACE AREA (SF) % IMPERV. IMPERV. AREA (SF) 2,164 2,482 0 198 100% 100% 100% 40% TOTALS 4,844 TOTAL= 4,725 EXISTING PROPOSED 2,164 79 1,928 853 0 2,482 0 P:\564-005\DWG\DRNG\564-005_IMPERVIOUS.DWG 609 S. COLLEGE AVE. FORT COLLINS COLORADO 301 N. Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com DESCRIPTION EXISTING VS. PROPOSED IMPERVIOUS AREA DRAWN BY B. Ruch DATE July 8, 2020 PROJECT 564-005 SK-C1 SCALE DRAWING 1"=30' CHANGE IN IMPERVIOUS AREA = 1,944 SF 1,360 SF ROOF UNMODIFIED + 145 SF WALK UNMODIFIED -------------------------------- 1,505 SF EXISTING IMPERVIOUS UNMODIFIED 75% TREATMENT NEW AND MODIFIED IMPERV. = 75% (4,725 -1,505) = 2,415 SF WATER QUALITY PROVIDED BY UDALL NATURAL AREA. 1 INCH = 20 FEET 20 20 DRAINAGE SUMMARY TABLE DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) Existing A Existing A 0.14 0.25 0.31 22.1 20.5 0.05 0.24 Existing B Existing B 0.01 0.25 0.31 5.9 5.5 0.01 0.03 Existing OS Existing OS 0.04 0.25 0.31 5.0 5.0 0.03 0.11 Proposed A Proposed A 0.14 0.55 0.69 13.2 12.3 0.16 0.70 Proposed B Proposed B 0.02 0.55 0.69 6.1 5.4 0.03 0.13 Proposed OS1 Proposed OS1 0.03 0.60 0.75 5.0 5.0 0.04 0.20 C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) Existing A Existing A 0.14 0.25 0.31 22.1 20.5 0.05 0.24 Existing B Existing B 0.01 0.25 0.31 5.9 5.5 0.01 0.03 Existing OS Existing OS 0.04 0.25 0.31 5.0 5.0 0.03 0.11 Proposed A Proposed A 0.14 0.55 0.69 13.2 12.3 0.16 0.70 Proposed B Proposed B 0.02 0.55 0.69 6.1 5.4 0.03 0.13 Proposed OS1 Proposed OS1 0.03 0.60 0.75 5.0 5.0 0.04 0.20 C Cf L Ti = − C Cf L Ti = − July 1, 2020 1) Runoff coefficients are taken from the Fort Collins Stormwater Criteria Manaual, Table 4.1-3and Table 3.2-2. 100-year Cf = 1.25 Composite Runoff Coefficient with Adjustment Existing OS 1,594 0.037 0.003 0.019 0.000 0.014 0.25 0.25 0.31 57% 1) Runoff coefficients are taken from the Fort Collins Stormwater Criteria Manaual, Table 4.1-3and Table 3.2-2. EXISTING COMPOSITE % IMPERVIOUSNESS AND RUNOFF COEFFICIENT CALCULATIONS 609 S. College Avenue B. Ruch July 1, 2020 100-year Cf = 1.25 Composite Runoff Coefficient with Adjustment