Loading...
HomeMy WebLinkAboutFUNSHINE EARLY CHILDHOOD - FDP200009 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLANOWNER'S CERTIFICATION THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN BY. OWNER (SIGNED) DATE THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________ A.D., 20 _______. BY __________________________________________________________ AS _________________________________________ (PRINT NAME) MY COMMISSION EXPIRES: ____________________________________ WITNESS MY HAND AND OFFICIAL SEAL ______________________________________ _____________________________________ NOTARY PUBLIC ADDRESS PLANNING CERTIFICATE APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OF THE CITY OF FORT COLLINS, COLORADO ON THIS __________ DAY OF ____________________ 20_____ ______________________________________ DIRECTOR SIGNATURE LAND USE TABLE ZONING CG - GENERAL COMMERCIAL DISTRICT EXISTING LAND USE VACANT, BUSINESS PROPOSED LAND USE EARLY CHILDHOOD CENTER OCCUPANCY EDUCATION & BUISNESS # OF CHILDREN TOTAL 52 CHILDREN TODDLERS 12 TODDLERS PRESCHOOLERS 30 PRESCHOOLERS ONE STORY BUILDING 3010 GROSS SF TOTAL PARKING PROVIDED 10 SPACES TOTAL PARKING REQUIRED (3 PER 1000 SF) 10 SPACES SITE AREA 13874 SF (.32 ACRES) IMPERVIOUS TOTAL AREA 6480 SF EXISTING CONCRETE PARKING TOTAL AREA 4982 SF EXISTING CONCRETE SIDEWALK TOTAL AREA 1172 SF NEW CONCRETE SIDEWALK TOTAL AREA 1480 SF NEW CONCRETE STOOP AT NEW EXIT DOOR 18 SF AREA DISTURBED DURING DEVELOPMENT 2500 SF NOTES: • EXISTING BUILDING FOOTPRINT TO REMAIN THE SAME. • EXISTING CONCRETE PARKING TO REMAIN THE SAME. • EXISTING DRAINAGE AND DOWNSPOUNTS TO REMAIN THE SAME. PROPERTY INFORMATION LEGAL DESCRIPTION LOT 6, CAMERON PARK, 1ST, FTC PARCEL # 9602406006 SITE PLAN NOTES 1. EXISTING LANDSCAPE AND TREES TO REMAIN. 2. NO EXTERIOR ALTERATIONS WILL BE MADE TO BUILDINGS. 3. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 4. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 5. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 6. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 7. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 8. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. UTILITY EASEMENT (E) 10' - 0" UTILITY EASEMENT (E) 6' - 0" UTILITY EASEMENT (E) 6' - 0" 2' - 0" SIDEWALK (E) 6' - 0" 1 EXISTING CONC WALK (803 SF) (N) PAINTED STRIPING, TYP (E) 20' - 0" +/- (E) 10' - 0" +/- (E) 26' - 0" +/- 19' - 2" (E) LIGHT POLE - PAD POLE G1.10 2 (E) RETAINING WALL, REMOVE (E) LAYER OF BRICK - SMOOTH EDGES W/ SKIM COAT & ADD VERTICAL STEEL GUARDRAIL EXISTING CONC WALK (116 SF) NEW CONC WALK (185 SF) NEW CONC WALK (123 SF) EXISTING BUILDING (3010 SF) EXISTING CONC PARKING LOT (4982 SF) (E) RETAINING WALL (E) RETAINING WALL 2 3 4 5 6 7 CAMERON DRIVE FRONTAGE ROAD CAMERON DRIVE PROPOSED FENCED OUTDOOR PLAY AREA (1335 SF) PROPOSED FENCED OUTDOOR PLAY AREA (753 SF) (E) PROPERTY LINE PROPOSED PROPERTY LINE 89° 11' 40" 166.55' S E 27° 15' 05" 84.69' S E 58° 13' 22" 38.08' S E 89° 11' 40" 83.03' S E 0° 42' 11" 82.80' N E NOTE: GRADE ESTIMATED FROM MAIN FLOOR LEVEL (100'-0"). EXISTING DRAINAGE PATTERNS WILL NOT BE CHANGED. 100' - 0" 90' - 0" (E) WATER LINE (E) SANITARY SEWER LINE UTILITY EASEMENT (E) 10' - 0" UTILITY EASEMENT (E) 6' - 0" UTILITY EASEMENT (E) 6' - 0" GRADING PLAN LEGEND EXISTING DRAINAGE SLOPE EXISTING WATER LINE EXISTING SANITARY SEWER LINE EXISTING PROPERTY LINE PROPOSED PROPERTY LINE PROPOSED CONTOUR LINE EXISTING CONTOUR LINE EASEMENT LINE 100' - 0" 100' - 0" Fort Collins, Colorado 123 College Ave., Suite 370 Ft. Collins, CO 80524-2377 970.818.8999 Lincoln, Nebraska Kansas City, Missouri Fairway, Kansas DRAFT LINE TYPE LEGEND (E) WALL DEMO (E) WALL NEW WALL DEMO (E) OTHER ADA CLEARANCE DIAPER STATION DIAPER STATION (E) ATTIC ACCESS ABOVE HALF HEIGHT WALL HALF HEIGHT WALL HALF HEIGHT WALL RECEPTION 100 CHILDREN'S TOILET 107 CHILDREN'S TOILET 102 CHILDREN'S TOILET 105 ADULT TOILET 104 KITCHENETTE 103 106 101A 103A 107 102 104 103B 101B +34" COUNTER 2020 Mop Sink 20' - 6" 3' - 5 1/2" 11' - 0 1/2" 3' - 1" 21' - 2" 16' - 1 1/2" 7' - 6 1/2" 23' - 3 1/2" 6' - 3" 10' - 4 1/2" 7' - 3 1/4" 7' - 3" 8' - 6" 8' - 6" 26' - 7 1/2" 26' - 4" 23' - 4 1/2" 23' - 7" (N) STOREFRONT DOOR SYSTEM IN (E) OPENING, TO MATCH (E) 54' - 0" 60' - 0" 25' - 0" 10' - 0" 25' - 0" TODDLERS 101 PRESCHOOLERS 106 (E) NON ADA COMPLIANT (E) Main Level 100' - 0" (E) Ceiling 108' - 2" (E) Roof Bear'g 108' - 10" (E) ROOF TO REMAIN (E) BRICK TO REMAIN (E) WINDOWS TO REMAIN, TYP (E) DOOR TO REMAIN (E) RETAINING WALL TO REMAIN 4:12 4:12 4:12 (N) ADDRESS SIGNAGE, TBD (E) Main Level 100' - 0" (E) Ceiling 108' - 2" (E) Roof Bear'g 108' - 10" 4:12 4:12 4:12 4:12 4:12 (E) ROOF TO REMAIN (E) BRICK TO (E) WINDOWS TO REMAIN REMAIN, TYP (E) DOOR TO REMAIN UPDATED LIGHT FIXTURES, TYP (E) Main Level 100' - 0" (E) Ceiling 108' - 2" (E) Roof Bear'g 108' - 10" (E) ROOF TO REMAIN (E) BRICK TO REMAIN (E) WINDOWS TO REMAIN, TYP (E) DOOR TO REMAIN (N) STOREFRONT DOOR TO MATCH (E) (E) RETAINING WALL TO REMAIN 4:12 4:12 4:12 4:12 4:12 (N) 3-LOOP WAVE STYLE BIKE RACK (N) ADDRESS SIGNAGE, TBD UPDATED LIGHT FIXTURES, TYP (E) Main Level 100' - 0" (E) Ceiling 108' - 2" (E) Roof Bear'g 108' - 10" (E) ROOF TO REMAIN (E) BRICK TO REMAIN (E) WINDOWS TO REMAIN, TYP 4:12 4:12 4:12 4:12 Fort Collins, Colorado 123 College Ave., Suite 370 Ft. Collins, CO 80524-2377 970.818.8999 Lincoln, Nebraska Kansas City, Missouri Fairway, Kansas DRAFT PREPARED FOR PRELIMINARY SUBMISSION AND REVIEW ONLY -- NOT FOR CONSTRUCTION. Landscape Architecture www.clarkenersen.com Architecture Engineering Interiors Plot Time Stamp: File Location/Name: 6/10/2020 11:10:59 AM \\Tcep-co-srv-004\300-399\322-001-20 Funshine EC Center\02) Revit 2020\322-001-20 Funshine EC Center-A20.rvt Exterior Elevations & Perspective A2.10 Views TCEP No.: 322-001-20 5137 S College Ave Fort Collins, CO 80525 Funshine Early Childhood Center 6/10/2020 Final Development Plan CLIENT FUNSHINE EARLY LEARNING CENTER 2700 South College Avenue, Unit 120 Fort Collins, CO 80525 SCALE: 3/16" = 1'-0" 1 East Elevation SCALE: 3/16" = 1'-0" 2 South Elevation SCALE: 3/16" = 1'-0" 3 West SCALE: 3/16" = 1'-0" 4 North SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" 5 East View 6 South View SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" 7 West View 8 North View DOOR SYSTEM TO REMAIN - NOT UTILIZED AS EXIT DOOR (E) ADA COMPLIANT DOOR SYSTEM TO REMAIN DIAPER STATION DIAPER STATION 105 10' - 6" 4' - 0" 4' - 0" 10' - 0" 8' - 0" 1' - 4" 1' - 4" 6' - 11" 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS SHOWN ON THE PLANS PRIOR TO COMMENCEMENT OF THE WORK. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO COORDINATE INSTALLATION OF NEW WORK WITHIN THESE EXISTING CONDITIONS. ANY DEVIATIONS IN EXISTING CONDITIONS OR DIMENSIONS INDICATED SHALL BE COORDINATED WITH THE ARCHITECT AND OWNER. 2. ALL WALL / GENERAL PLAN DIMENSIONS ARE TO FACE OF MASONRY, FACE OF CONCRETE, AND TO FACE OF STUD, TYP. 3. CONSTRUCTION OF WALLS ARE DESIGNATED STARTING ON TAG SIDE OF WALL. 4. ALL INTERIOR WALL FRAMING NOTED IN WALL TYPE SCHEDULE EXTENDS TO STRUCTURAL DECKING, BRACE AS REQUIRED. PROVIDE DEEP LEG SLIP TRACK AT TOP OF ALL INTERIOR WALLS / STUDS EXTENDING TO STRUCTURE TO ALLOW FOR DEFLECTION OF STRUCTURE. 5. INTERIOR DOOR FRAMES SHALL BE INSTALLED WITH THE HINGE SIDE OF DOOR FRAME 4" FROM ADJACENT WALL, UNLESS OTHERWISE DIMENSIONED. 6. PROVIDE BULLNOSE UNITS @ ALL DOOR AND WINDOW OPENINGS, END WALLS, AND OUTSIDE CORNERS IN CMU WALLS. 7. ALL STEEL STUDS ARE MIN. 25 GA. UNLESS NOTED OTHERWISE. 20 GA STEEL STUDS REQUIRED AT ALL CEMENTITIOUS BACKER BOARD AND ABUSE RESISTANT GYPSUM BOARD AS SPECIFIED. 8. 5/8" CEMENTITIOUS BACKER BOARD SHALL BE SUBSTITUTED FOR GYP. BOARD IN ALL LOCATIONS WHERE CERAMIC AND /OR PORCELAIN WALL TILE FINISHES ARE TO BE INSTALLED. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR PRICING AND INSTALLATION OF APPROPRIATE FRAMING NEEDED FOR WALLS HEIGHT. REFER TO “INTERIOR STEEL STUD FRAMING GAGE TABLE (1)” ON SHEET A0.00 FOR FRAMING GAGES AND STUD SIZING REQUIREMENTS. 10. REFER TO CODE COMPLIANCE PLANS FOR LOCATION OF FIRE RATED WALLS AND SMOKE SEPARATION WALL LOCATIONS AND REQUIREMENTS. 11. ALL OPENINGS IN RATED ASSEMBLIES SHALL BE SEALED WITH FIRE / SMOKE RATED MATERIALS AND ASSEMBLIES. INSTALL RATED JOINT SEALANTS AT BOTH FACES OF PARTITIONS, AT PERIMETERS, AND THROUGH FIRE RATED ASSEMBLIES. REFERENCE CODE COMPLIANCE PLANS FOR LOCATION OF RATED ASSEMBLIES. 12. ALL EXPANSION JOINT COVERS WITH CONNECTION TO RATED ASSEMBLIES SHALL MEET THE SAME REQUIRED RATING AS THE ASSEMBLY. REFERENCE CODE COMPLIANCE PLANS FOR LOCATION OF RATED ASSEMBLIES. 13. ALL STC-RATED WALL ASSEMBLIES AND PARTITIONS INDICATED SHALL HAVE STAGGERED SHEATHING AND GYP. BOARD JOINTS ON OPPOSITE SIDES OF ASSEMBLIES. REFERENCE WALL TYPE SCHEDULE FOR SOUND ATTENUATION INSULATION REQUIRED WITHIN STUD CAVITIES. SEAL ASSEMBLIES AT CONSTRUCTION PERIMETERS, DECKING MATERIAL (TOP & BOTTOM), BEHIND CONTROL JOINTS, AND AT ALL OPENINGS AND PENETRATIONS WITH A CONTINUOUS BEAD OF ACOUSTICAL JOINT SEALANT. INSTALL ACOUSTICAL JOINT SEALANTS AT BOTH FACES OF ASSEMBLIES 14. GENERAL CONTRACTOR SHALL COORDINATE REPAINTING OF WALLS BETWEEN SUBCONTRACTORS AFTER EXISTING FIXTURES ARE SCHEDULED TO BE REMOVED AND PRIOR TO FIXTURES BEING REINSTALLED. REFER TO ELECTRICAL & MECHANICAL PLANS. GENERAL PLAN NOTES DOOR & FRAME TYPE GENERAL NOTES 1. PROVIDE SAFETY GLAZING OR FIRE-PROTECTION-RATED GLAZING IN LOCATIONS REQUIRED BY CURRENT LOCAL CODE. NOTIFY ARCHITECT OF CHANGES REQUIRED TO THE DRAWINGS. PROVIDE OBSCURE GLAZING AS INDICATED. 2. PROVIDE AND INSTALL SAFETY GLAZING IN LOCATIONS AS PER SECTION 2406 & 2408 OF THE 2009 INTERNATIONAL BUILDING CODE. 3. ALL DIMENSIONS ARE NOMINAL. ACTUAL DIMENSIONS TO BE PROVIDED BY SUPPLIER W/ ADJUSTMENTS MADE FOR INSTALLATION TOLERANCES REQUIRED. VERIFY ALL EXISTING OPENINGS PRIOR TO ORDER OF ALL NEW DOORS, DOOR FRAMES AND WINDOW FRAMES. 4. SEE FLOOR PLANS FOR DIRECTION OF DOOR SWINGS. 5. REFER TO WALL TYPE THICKNESS FOR THROAT DEPTHS OF HOLLOW METAL DOOR AND WINDOW FRAMES INSTALLED IN STEEL STUD WALLS W/ GYPSUM. 6. ALL INTERIOR HOLLOW METAL DOOR FRAMES SHALL BE FILLED FULL W/ BATT INSUL. COORDINATE WITH ELECTRICAL TRADES, FINISH HARDWARE AND ELECTRONIC EQUIPMENT. 7. ALL EXTERIOR ALUMINUM WINDOW FRAMING WERE DESIGNED TO EFCO SERIES 403 OR AS NOTED ON THE DRAWINGS WITH 1" INSULATED LOW 'E' GLAZING. INTERIOR HOLLOW METAL WINDOW FRAMING DESIGNED WITH INSULATED AND NON-INSULATED GLAZING AS NOTED ON THE DRAWINGS. 8. ALL INTERIOR DOOR FRAMES OF STUD WALLS W/ GYPSUM WALLS BEGIN 4" FROM THE FINISH FACE OF THE ADJACENT WALLS UNLESS OTHERWISE NOTED. 9. MULLION LOCATIONS SHALL BE AS INDICATED ON THE DRAWINGS AND SHALL BE REFLECTED IN THE SHOP DRAWINGS. NOTIFY ARCHITECT OF ANY CHANGES OR DEVIATIONS. 10. BORROWED LIGHT LOCATIONS SHALL BE AS INDICATED ON THE PLAN DRAWINGS AND SHALL BE REFLECTED IN THE SHOP DRAWINGS. NOTIFY ARCHITECT OF ANY CHANGES OR DEVIATIONS. FLOOR LINE WDF - 1 0' - 2" REF: SCHED. DOOR WIDTH / PAIR WIDTH 0' - 2" 0' - 2" REF: SCHED. DOOR HEIGHT 0' - 2" REF: SCHED. DOOR WIDTH 0' - 2" REF. SCHED. DOOR HEIGHT NO HEADER WDF - 2 FLOOR LINE WD - 1 REF: SCHED. DOOR HEIGHT REF: SCHED. DOOR WIDTH WD - 2 REF: SCHED. DOOR HEIGHT REF: SCHED. DOOR WIDTH FLOOR LINE REF: SCHED. DOOR WIDTH REF: SCHED. DOOR HEIGHT ALD - 1 TEMPERED GLASS 0' - 5" 0' - 10" 0' - 8" NOTE: CONFIRM DIM W/ (E) STOREFRONT SYSTEM Fort Collins, Colorado 123 College Ave., Suite 370 Ft. Collins, CO 80524-2377 970.818.8999 Lincoln, Nebraska Kansas City, Missouri Fairway, Kansas DRAFT PREPARED FOR PRELIMINARY SUBMISSION AND REVIEW ONLY -- NOT FOR CONSTRUCTION. Landscape Architecture www.clarkenersen.com Architecture Engineering Interiors Plot Time Stamp: File Location/Name: 6/10/2020 11:06:27 AM \\Tcep-co-srv-004\300-399\322-001-20 Funshine EC Center\02) Revit 2020\322-001-20 Funshine EC Center-A20.rvt Floor A1Pla.n11 TCEP No.: 322-001-20 5137 S College Ave Fort Collins, CO 80525 Funshine Early Childhood Center 6/10/2020 Final Development Plan CLIENT FUNSHINE EARLY LEARNING CENTER 2700 South College Avenue, Unit 120 Fort Collins, CO 80525 SCALE: 1/4" = 1'-0" Main Level Floor Plan DOOR SCHEDULE DOOR NO. PAIR WIDTH DOOR FRAME HARDWARE REMARKS WIDTH HEIGHT TYPE FINISH TYPE FINISH 101A 3' - 0" 6' - 8" WD-1 PT WDF-1 PT 2 101B 3' - 0" 6' - 8" ALD-1 - ALD - 1 102 3' - 0" 6' - 8" WD-1 PT WDF-1 PT 2 103A 3' - 0" 6' - 8" WD-1 PT WDF-1 PT 2 103B 3' - 0" 6' - 8" WD-1 PT WDF-1 PT 1 104 3' - 0" 6' - 8" WD-1 PT WDF-1 PT 2 105 3' - 0" 6' - 8" WD-1 PT WDF-1 PT 2 106 3' - 0" 3' - 0" WD-2 PT WDF-2 PT 3 107 3' - 0" 6' - 8" WD-1 PT WDF-1 PT 1 DOOR SCHEDULE REMARKS NO. DOOR REMARKS 1 RE-USE (E) DOOR 2 MATCH (E) DOOR PANELS, DOOR FRAMES, & CASING 3 HALF HEIGHT DOOR SCALE: 1/4" = 1'-0" WOOD FRAME TYPE SCALE: 1/4" = 1'-0" WOOD DOOR TYPES SCALE: 1/4" = 1'-0" ALUMINUM DOOR TYPES PREPARED FOR PRELIMINARY SUBMISSION AND REVIEW ONLY -- NOT FOR CONSTRUCTION. Landscape Architecture www.clarkenersen.com Architecture Engineering Interiors Plot Time Stamp: File Location/Name: 6/10/2020 11:08:30 AM \\Tcep-co-srv-004\300-399\322-001-20 Funshine EC Center\02) Revit 2020\322-001-20 Funshine EC Center-A20.rvt Grading G1P.lan11 TCEP No.: 322-001-20 5137 S College Ave Fort Collins, CO 80525 Funshine Early Childhood Center 6/10/2020 Final Development Plan SCALE: 1" = 10'-0" Grading Plan (E) RETAINING WALL (N) CURB STOPS, TYP (N) CONC STOOP (18 SF) 6' - 0" 5' - 0" NOTE: GRADE ESTIMATED FROM MAIN FLOOR LEVEL (100'-0"). EXISTING DRAINAGE PATTERNS WILL NOT BE CHANGED. (E) WATER LINE (E) SANITARY SEWER LINE 1 2 3 4 5 6 7 8 15' - 3" REMOVAL OF (E) TREE REMOVAL OF (E) TREE (N) RETAINING WALL, AS NEEDED (N) RETAINING WALL, AS NEEDED 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 17' - 10 3/4" 17' - 1 1/4" 21' - 0" 4' - 0" 9' - 0" 9' - 0" 8 9 10 9' - 0" 9' - 0" 9' - 0" (N) ADA PARKING SIGNAGE 3-LOOP WAVE STYLE BIKE RACK - 5 BIKE CAPACITY 11 3' - 0" 11' - 4" 10' - 0" 15' - 6" 2' - 6" 1' - 8" REMOVED (E) LANSCAPE UP LIGHT 20' - 0" 11' - 6" (6) - (N) FASTIGIATE TREES, 8' TALL MIN TRANSPLANTING TREE #4 - SPRING SNOW CRABAPPLE, SHALL FOLLOW THE RECOMMENDATIONS OF A QUALIFIED TREE TRANSPLANTING CONTRACTOR IN TERMS OF SIZE, STAKING, MULCHING AND IRRIGATION (N) ONE-WAY SIGNAGE PER MUTCD R6-1 STANDARDS (N) DO NOT ENTER SIGNAGE PER MUTCD R5-1 STANDARDS M M M M M M T (E) PROPERTY LINE PROPOSED PROPERTY LINE 89° 11' 40" 83.03' S E 0° 42' 11" 82.80' N E 89° 11' 40" 166.55' S E 27° 15' 05" 84.69' S E 58° 13' 22" 38.08' S E 44° 57' 01" 16.06' N E 100' - 0" 95 GALLON RECYCLING CART METAL ACCESS GATE REINFORCED 8" CMU ENCLOSURE W/ PRECAST CAP - 5'-4" TALL 95 GALLON RECYCLING CART 2 YARD TRASH BIN 2' - 8 1/2" G1.10 3 G1.10 4 SITE PLAN LEGEND EXISTING TREE TO REMAIN AND BE PROTECTED NEW FENCE EXISTING CONCRETE NEW CONCRETE PARKING SIGNAGE RE: PLAN FOR MOUNTING NEW TREE EXISTING CHAIN DOWN SPOUTS 6' PARKING CURB STOP, UNO EXISTING DRAINAGE SLOPE REMOVED (E) TREE NEW MULCH/RUBBER CHIP AREA T PARKING TABLE (LUC 3.2.2) PARKING SPACE # STALL DESCRIPTION DIMENSIONS #1 - #6 (6 SPACES) 60 DEGREE COMPACT 9' x 17.9' #8, #9, #10 (3 SPACES) 60 DEGREE STANDARD 9' x 21' #7 (1 SPACE) 60 DEGREE ADA 9' x 21' #11 (5 SPACES) FIXED BIKE PARKING 3 LOOP WAVE REINFORCED 8" CMU BLOCK PRECAST CAP 4"x4" STL TUBE COLUMN FILLED W/ CONC, EMBEDDED INTO 3'-0"D x 1'-0"W FOOTING - BOTH SIDES 1' - 0" 5 G1.10 5' - 4" 6' - 0" 3' - 4" 8" 3' - 0" 5' - 4" STEEL CANE BOLT W/ SLEEVE STEEL GATES - ANGLE FRAME AND DIAGONAL BRACE W/ METAL INFILL PANEL 4"x4" STL TUBE COLUMN FILLED W/ CONC, EMBEDDED INTO 3'-0"D x 1'-0"W FOOTING - BOTH SIDES (3) HEAVY DUTY STEEL HINGES, EACH SIDE 8" CMU BLOCK W/ PRECAST CAP BEYOND 3' - 0" 1' - 0" 3' - 0" 5' - 4" 1' - 0" 1' - 0" 5' - 4" 1' - 0" 3' - 4" INTERIOR EXTERIOR PRESERVATIVE TREATED WOOD BLOCKING 8" CMU WALL, REINFORCE WITH #4 AT 32" VERTICAL IN GROUTED CELL. (1) #4 BOND BEAM AT TOP OF WALL AND HORIZONTAL JOINT REINFORCING AT 16" PRECAST CAP OR OTHER CAPPING METHOD - OVERHANG CMU WALL, SLOPED TOP WALL FOOTING REINFORCE W/ (2) #4 TOP AND BOTTOM AND WITH #4 DOWELS AT 16" REINFORCED 5" THICK CONCRETE SLAB LAND USE TABLE ZONING CG - GENERAL COMMERCIAL DISTRICT EXISTING LAND USE VACANT, BUSINESS PROPOSED LAND USE EARLY CHILDHOOD CENTER OCCUPANCY EDUCATION & BUISNESS # OF CHILDREN TOTAL 52 CHILDREN TODDLERS 12 TODDLERS PRESCHOOLERS 30 PRESCHOOLERS ONE STORY BUILDING 3010 GROSS SF TOTAL PARKING PROVIDED 10 SPACES TOTAL PARKING REQUIRED (3 PER 1000 SF) 10 SPACES SITE AREA 13874 SF (.32 ACRES) IMPERVIOUS TOTAL AREA 6480 SF EXISTING CONCRETE PARKING TOTAL AREA 4982 SF EXISTING CONCRETE SIDEWALK TOTAL AREA 1172 SF NEW CONCRETE SIDEWALK TOTAL AREA 1480 SF NEW CONCRETE STOOP AT NEW EXIT DOOR 18 SF AREA DISTURBED DURING DEVELOPMENT 2500 SF NOTES: • EXISTING BUILDING FOOTPRINT TO REMAIN THE SAME. • EXISTING CONCRETE PARKING TO REMAIN THE SAME. • EXISTING DRAINAGE AND DOWNSPOUNTS TO REMAIN THE SAME. PROPERTY INFORMATION LEGAL DESCRIPTION LOT 6, CAMERON PARK, 1ST, FTC PARCEL # 9602406006 6" 6" 8' - 0" EQ EQ 4x4 POST, TYP 1x6 DOG-EARED FENCE PANEL, TYP 2" 6' - 0" 2x4 BRACE, TYP 3' - 0" 10" 3' - 0" 10" Fort Collins, Colorado 123 College Ave., Suite 370 Ft. Collins, CO 80524-2377 970.818.8999 Lincoln, Nebraska Kansas City, Missouri Fairway, Kansas DRAFT PREPARED FOR PRELIMINARY SUBMISSION AND REVIEW ONLY -- NOT FOR CONSTRUCTION. Landscape Architecture www.clarkenersen.com Architecture Engineering Interiors Plot Time Stamp: File Location/Name: 6/10/2020 11:11:16 AM \\Tcep-co-srv-004\300-399\322-001-20 Funshine EC Center\02) Revit 2020\322-001-20 Funshine EC Center-A20.rvt Site GPl1an.10 TCEP No.: 322-001-20 5137 S College Ave Fort Collins, CO 80525 Funshine Early Childhood Center 6/10/2020 Final Development Plan SCALE: 1" = 10'-0" Site Plan SCALE: 1/4" = 1'-0" 2 Trash Enclosure CLIENT FUNSHINE EARLY LEARNING CENTER 2700 South College Avenue, Unit 120 Fort Collins, CO 80525 SCALE: 3/8" = 1'-0" 3 Trash Enclosure - Southeast SCALE: 3/8" = 1'-0" 4 Trash Enclosure - Southwest SCALE: 3/4" = 1'-0" 5 Trash Enclosure - Section TOTAL MITIGATION TREES REQUIRED 6 8 AUSTRIAN PINE 26" FAIR MINUS 2.5 REMOVE OKAY STRUCTURE 7 AUSTRIAN PINE 5 10"-20" FAIR MINUS 3.0 REMOVE MULTISTEM 6 AUSTRIAN PINE 21" FAIR PLUS 3.5 REMAIN 5 CRABAPPLE, SPRING SNOW 2" GOOD 0.0 REMOVE TRANSPLANTABLE 4 CRABAPPLE, SPRING SNOW 2" GOOD 0.0 TRANSPLANT TRANSPLANTABLE 3 CRABAPPLE 11" FAIR 1.5 REMAIN IN ROCK BED 2 CRABAPPLE 14" FAIR PLUS 2.0 REMAIN IN ROCK BED 1 CRABAPPLE 18" FAIR 2.5 REMAIN IN ROCK BED # SPECIES STEMS DBH CONDITION MITIGATION VALUES TO REMAIN NOTES TREE INVENTORY AND MITIGATION TABLE SCALE: 3/8" = 1'-0" 6 Fence Elevation 1 MALUS / CRAB APPLE, SPRING SNOW (E) (E) (E) NO TRANSPLANT, RE: TREE INVENTORY 6 JUNIPERUS VIRGINIANA / TAYLOR JUNIPER 8' 2' 2.0" CAL. BB YES WELL BRANCHED W/ STRAIGHT TRUNK & CENTRAL LEADER KEY QTY SCIENTIFIC/ COMMON NAME HEIGHT WIDTH SIZE MITIGATION TREE NOTES PLANT LIST 9. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 10. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 11. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED 12. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSABLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 13. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY THE PROPERTY OWNER OF THE COMMON AREA. THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 14. DESIGN AND INSTALLATION OF ALL PARKWAY/TREE LAWN AND MEDIAN AREAS IN THE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH CITY STANDARDS. UNLESS OTHERWISE AGREED TO BY THE CITY WITH THE FINAL PLANS, ALL ONGOING MAINTENANCE OF SUCH AREAS IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER. 15. THE PROPERTY OWNER FOR EACH RESIDENTIAL LOT IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH RESIDENTIAL LOT. 16. PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES (IF LOCATED IN BACK YARDS), ODORCONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS. 17. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 18. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 19. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. STREET TREE NOTE: 1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2. CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE. 3. STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE.STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR. 4. THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE. 5. SUBJECT TO APPROVAL BY THE CITY FORESTER -- STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES, STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATION STANDARDS. TREE PROTECTION NOTES: 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA. GENERAL LANDSCAPE NOTES: 1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE – FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OR EQUIVALENT. 2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. IRRIGATION SYSTEMS TO BE TURNED OVER TO THE CITY PARKS DEPARTMENT FOR MAINTENANCE MUST BE APPROVED BY THE PARKS MANAGER AND MEET PARKS IRRIGATION STANDARDS. DESIGN REVIEW SHALL OCCUR DURING UTILITIES DEPARTMENT IRRIGATION REVIEW PRIOR TO THE ISSUANCE OF A BUILDING PERMIT AND CONSTRUCTION OBSERVATION AND INSPECTION BY PARKS SHALL BE INCORPORATED INTO THE CONSTRUCTION PROCESS. 3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING. 4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE THOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN SECTION 12-132. 5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE. 6. MAINTENANCE:TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION. 7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS. 8. THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES: 40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS 15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS 10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES 6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES. 4 FEET BETWEEN SHRUBS AND PUBLIC WATER AND SANITARY AND STORM SEWER LINES 4 FEET BETWEEN TREES AND GAS LINES 9. ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a). 10. PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDED THAT THE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN. 11. THE FINAL LANDSCAPE PLAN SHALL BE COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THE PROPOSED GRADING, STORM DRAINAGE, AND OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN. 12. MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, AND DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THE PLANT LIST, SPECIES AND QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION. 13. ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES. PARKING TABLE (LUC 3.2.2) PARKING SPACE # STALL DESCRIPTION DIMENSIONS #1 - #6 (6 SPACES) 60 DEGREE COMPACT 9' x 17.9' #8, #9, #10 (3 SPACES) 60 DEGREE STANDARD 9' x 21' #7 (1 SPACE) 60 DEGREE ADA 9' x 21' #11 (5 SPACES) FIXED BIKE PARKING 3 LOOP WAVE CONTEXT MAP NOT TO SCALE SITE VICINITY MAP FOSSIL CREEK DR REDTAIL GROVE NATURAL AREA TRAIN TRACK CONEJOS RD FOSSIL BLVD W FAIRWAY LN CORONADO CT FOSSIL RIDGE DR S COLLEGE AVE W FAIRWAY LN FRONTAGE RD CAMERON DR FOSSIL CREEK PKWY FOSSIL RIDGE DR PARKWAY CIR W GREENWAY DR GRIFFITH DR GREENVIEW DR GREENVALE DR PARKWAY CIR N SNEAD DR UE CG UE POL RL SITE Fort Collins, Colorado 123 College Ave., Suite 370 Ft. Collins, CO 80524-2377 970.818.8999 Lincoln, Nebraska Kansas City, Missouri Fairway, Kansas DRAFT PREPARED FOR PRELIMINARY SUBMISSION AND REVIEW ONLY -- NOT FOR CONSTRUCTION. Landscape Architecture www.clarkenersen.com Architecture Engineering Interiors Plot Time Stamp: File Location/Name: 6/10/2020 11:08:04 AM \\Tcep-co-srv-004\300-399\322-001-20 Funshine EC Center\02) Revit 2020\322-001-20 Funshine EC Center-A20.rvt Cover G0.Sheet 00 TCEP No.: 322-001-20 5137 S College Ave Fort Collins, CO 80525 Funshine Early Childhood Center 6/10/2020 Final Development Plan SHEET INDEX G GENERAL G0.00 Cover Sheet G1.10 Site Plan G1.11 Grading Plan A ARCHITECTURAL A1.11 Floor Plan A2.10 Exterior Elevations & Perspective Views E ELECTRICAL E-1-0 Site Lighting Plan E-2.0 Electrical Cut Sheets OVER 19 15 15-19 12 10-14 10 5-9 5 3-4 2 0-2 1 TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) CLIENT FUNSHINE EARLY LEARNING CENTER 2700 South College Avenue, Unit 120 Fort Collins, CO 80525 Funshine Early Childhood Center Final Development Plan 5137 S College Ave Fort Collins, CO 80525 June 10, 2020