HomeMy WebLinkAboutPINECONE PUD THE TOWER SHOPPES SONIC DRIVE IN FINAL - 60 91O - CORRESPONDENCE - STAFF'S PROJECT COMMENTS(M! r, AMI STAFF PROJECT REVIEW
City of Fort Collins
ALLER-LINGLE ARCHITECTS, P.C. Date: 11/07/2005
DAVID LINGLE
712 WHALERS WAY, SUITE B-100
FORT COLLINS, CO 80525
Staff has reviewed your submittal for PINECONE PUD, THE TOWER SHOPPES, SONIC
DRIVE-IN PDP - TYPE II AND FINAL PLANS, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Anne Aspen
Topic: Erosion Control
Number: 57 Created: 11 /7/2005
[11/7/05] Tim Buchanan, the City Forester comments that there are two existing trees on
Horsetooth that need to be replaced with Marshall Ash trees. Please see redlines for more
detail.
Topic: General
Number: 30 Created: 10/17/2005
[10/17/051 The sidewalk between the cars under the canopy is still raising questions for me.
In your response letter, you state that it has been changed to 9 feet wide. On the plans,
they are shown as 7 feet and in your sections they are 6 feet. Please make it consistent.
Also, since the employee parking is long term, and you can overhang by 2 feet, it can be
reduced to 16 feet if needed. That might give you a bit of extra room if you need it. Back to
the center walk for the carhops, I think that you need to make it 8 feet or more since cars will
overhang on both sides. Another option would be to provide wheel stops at the drive-in
spaces to prevent overhang.
Number: 31 Created: 10/17/2005
[10/17/05] I've made a number of very minor redlines on your plans which I won't list in
detail here. Please refer to them on the plans.
Topic: Photometrics
Number: 32 Created: 10/17/2005
[10/17/05] You show a fixture on your plans that is not on the photometrics. Please clarify.
Number: 33 Created: 10/17/2005
[10/17/05] Lighting levels generally seem very high. The site could be adequately lit with
half the luminance shown and should be given the residential nature of the surrounding
areas.
Number: 34 Created: 10/17/2005
[10/17/05] Measurements under the canopies seem especially high --are they plotted as if
pointing down? I realize the lighting solution is an unusual one. If it is not possible to chart
the canopy lights, you can show a max (say, as if pointed down) and make a note on the
plans to explain.
Number: 35
Created: 10/17/2005
Page 1
[10/17/05] Please add and label the fixture cutsheets (just picture/drawing only, and not the
poles or brackets, etc.) to the photometric plan sheet. The lighting pole foundation detail is
fine.
Topic: Transportation
Number: 48 Created: 11 /1 /2005
[11/1/05] Xcel Energy comments:
PSCO gas main lays approximately 16' south of the north property line [ROW] of Horsetooth
Rd. You will need a permit to cut Horsetooth to install proposed gas service to Sonic.
Number: 49 Created: 11 /1 /2005
[11/1/05] Park Planning has no issues or concerns with this submittal.
Department: Engineering Issue Contact: Marc Virata
Topic: General
Number: 51 Created: 11 /4/2005
[11/4/051 The legal descriptions for the various easement dedications/vacation closed
correctly in our review. Please provide actual deeds of dedication, which will be required
prior to sign off on the mylars. The emergency access easement being provided appears to
cross into several lots, including Lot 3 (McDonald's). It appears that several different owners
(including McDonald's) would need to convey the full easement.
Number: 52 Created: 11 /4/2005
[11/4/05] The school district will need to sign off on the construction plans prior to our sign
off.
Number: 54 Created: 11 /4/2005
[11/4/05] Please coordinate the title of the site, landscape, and construction plan
documents to one consistent title. My preference would be "Sonic Drive -In - Lot 4 Tower
Shoppes P.U.D."
Number: 55 Created: 11 /4/2005
[11/4/05] Please provide a note on the construction plans as follows: The emergency
access connection from Horsetooth Road to Timberline Road shall meet all access
requirements of the Poudre Fire Authority. Any substandard pavement conditions
determined by the Poudre Fire Authority shall be remedied by the Developer."
Department: Natural Resources Issue Contact: Doug Moore
Topic: General
Number: 29 Created: 10/7/2005
[10/7/05] No issues.
Department: PFA Issue Contact: Michael Chavez
Topic: General
Number: 37 Created: 10/25/2005
[10/25/05] REQUIRED ACCESS:
A fire lane is required. The fire lane shall be visible by painting and signage, and maintained
unobstructed. 1997 UFC 901.2.2.1; 901.3; 901.4.2; 902.2.1; FCLUC
The criteria for a required fire lane contain several conditions that must be met.
1. The minimum width shall be 20 feet.
2. Inside turning radius shall be 25 feet and outside turning radius shall be 50 feet.
Page 2
3. Compacted road base shall be used during the construction phase only. The
permanent fire lane shall consist of asphalt or concrete and shall be required to support 40
tons
4. The fire lane shall be platted as an "Emergency Access Easement" on the final plat.
Number: 38 Created: 10/25/2005
[10/25/05] PREMISES IDENTIFICATION: Approved numerals or addresses shall be
provided for all new and existing building in such a position as to be plainly visible and
legible from the street or road fronting the property. 1997 UFC 901.4.4
Number: 39 Created: 10/25/2005
[10/25/05] WATER SUPPLY: Commercial
No commercial building can be greater then 300 feet from a fire hydrant.
Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway
Each hydrant must be capable of delivering 1500 gallons of water per minute at a residual
pressure of 20 psi. 1997 UFC 901.2.2.2
Number: 40 Created: 10/25/2005
[10/25/05] COMMERCIAL COOKING FIRE EXTINGUISHING SYSTEM:
With the production of grease laden vapors, an approved automatic fire -extinguishing
system shall be provided for the protection of commercial -type cooking equipment.
1997 UFC 1006.1; 1006.2.1
Number: 41 Created: 10/25/2005
[10/25/05] KNOX BOX:
Poudre Fire Authority requires a "Knox Box" to be mounted on the front of every new
building equipped with a required fire sprinkler system or fire alarm system.
1997 UFC 902.4; PFA POLICY 88-20
Department: Police Issue Contact: Joseph Gerdom
Topic: Photometrics
Number: 50 Created: 11 /2/2005
[11/2/05] Did not see a revised landscape plan - assume the plant materials in SE corner
near rear entrance and trash enclosure were changed to reduce concealment/lighting
issues.
Department: Transportation Planning Issue Contact: David Averill
Topic: Transportation
Number: 47 Created: 11 /1 /2005
[11/1/05] No further comments or concerns
Department: Water Utilities Issue Contact: Basil Harridan
Topic: Construction on Poudre School District property
Number: 42 Created: 10/31 /2005
[10/31/05] Construction of the storm line on school property will require that the school
district approve of these plans. It is important that Jerry Garretson of the Poudre School
District be routed a copy of these plans so that he can proceed with reviewing them and
providing PSD approval. It will also be important to make sure that the construction
schedule is coordinated with the school district in order to minimize the impact on school
operations.
Page 3
Topic: Detention Pond Design
Number: 43 Created: 10/31 /2005
[10/31 /05]
It is not clear what portion of Lot 1 was accounted for in the design of the water quality pond.
The text states that the west portion of that lot including the parking lot will be
accommodated in this design. Since this is an interim design that will be modified once Lot
1 is developed it would be important to highlight that in the drainage report and explain, that
if the same volume is to be maintained in the ultimate detention pond, how much impervious
are of Lot 1 would be accommodated by the current design. Please justify how the 4.3
acres was arrived at to calculate the contributing area to the pond.
The water quality detention pond looks like it has 3:1 side slopes, 4:1 sides slopes are
preferable from a maintenance standpoint.
Please provide a spillway design for the water quality pond. Grading plans call for a spill
elevation of 4938.3 while the water quality outlet detail shows a spill elevation 4939.0
Topic: Erosion Control
Number: 44 Created: 10/31 /2005
[10/31/051 Comments from Bob Zakely regarding the erosion control plan will be forwarded
directly to the engineer on Monday November 7th.
Number: 56 Created: 11 /7/2005
[11 /7/05]
November 3, 2005
Please provide a complete stormwater management plan submittal per City specifications
including a report, schedule, calculations, and surety.
Topic: Off -site drainage easement
Number: 45 Created: 10/31 /2005
[10/31/05] Please provide a drainage easement for the area that will be covered by the
water quality pond.
Department: Zoning Issue Contact: Gary Lopez
Topic: Zoning
Number: 36 Created: 10/24/2005
[10/24/051 There is still no note regarding landscape securement of 125% of landscaping
costs (plant/material) for CO if landscaping is incomplete. See above.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Sincerely,
Anne H. Aspen
City Planner
Page 4