HomeMy WebLinkAboutPINECONE PUD THE TOWER SHOPPES SONIC DRIVE IN FINAL - 60 91O - SUBMITTAL DOCUMENTS - ROUND 1 - RESPONSE TO STAFF REVIEW COMMENTSG. Response to Project Development Plan Review Staff Comments
ITEM: Sonic Drive -In Restaurant on Lot 4 of Tower Shoppes P.U.D.
APPLICANT: Mr. Scott Beard, Sonic Drive -In Restaurant c/o David Lingle,
Aller.Lingle Architects, 712 Whalers Way, Building B, Suite 100, Fort
Collins, CO 80525.
LAND USE DATA: Request to build a new 2,498 square foot restaurant featuring both
indoor dining and drive-in service (but no drive -through service). The site is located on
Lot 4 of the Tower Shoppes P.U.D., at the northeast corner of Timberline and Horsetooth
Roads, immediately east of McDonald's Restaurant. The site has been addressed as 3518
South Timberline. The pad site is 0.783 acre in size. A detached canopy would shade 19
drive-in parking spaces with menu and carhop service. Additional parking next to the
building is provided for indoor dining customers. An outdoor patio would be added to the
east side of the building.
COMMENTS:
(responses in bold)
27. If at all possible, please add a window to the west side of the south elevation.
We've come this far in site orientation, it'd be nice to go all the way.
Design of the building has incorporated two (2) tube steel frames to mimic the
window frames on the north elevation and window proportions of the top and
bottom of the large window on the east elevation.
21. 1 have made a number of CAD/drawing comments on the plans. Please refer to
them and return the redlines when you resubmit.
Responded and returned.
22. Please provide a rendered perspective, elevations and/or material sample boards
so we can evaluate colors and materials used.
Color rendered elevations included.
23. 1 need cut sheets for all of the proposed light fixtures. These should include
manufacturer's drawings or photos and info on wattage, LLF's, etc.
Cut sheets attached.
5. The following departments/ agencies have indicated that they have no issues or
concerns with the project: Streets, Comcast, Park Planning, and US Postal Service.
Noted.
6. Water Conservation and Building Inspection have standard comments and handouts
for you that I will include in your redline packet.
Noted.
11. In field observations, the existing hydrant towards the southeast corner of the site
appears to be directly in the path of the sidewalk proposed to be extended along
the eastern boundary of the site. Is the drawing accurate with regards to the
Location of the hydrant in relation to the sidewalk? What will be the separation
distance between the sidewalk and the hydrant?
I r
Existing topography was checked and the hydrant location in the drawings
seems to correspond with the location in the field. The proposed walk will be
built to the west of the existing hydrant with approximately 3 feet of
separation.
24. Please provide information as to where the emergency access easement (offsite)
will be situated. The response letter indicates that the emergency access
easement will occur around the perimeter of the site; however, the drawings only
indicate the portion off of Horsetooth. Will it connect out to Timberline?
A 24"x36" Offsite Easement Exhibit has been provided to help clarify the
location of the offsite easements.
25. Letters of intent are required from all the affected offsite property owners. This
includes Lot 3 and Lot 1 and involves various easements (emergency access,
Landscaping, construction, drainage, etc.)
Letters of intent have been provided.
Normal electric development charges and policies will apply to this development.
Noted.
2. Developer will need to submit a Commercial Service Form (C-1) in order to size the
transformer and determine electrical requirements.
Noted.
9. No issues.
Noted.
10. The two P5 fixtures next to the building are buried in a Bur Oak - need to relocate
these two light fixtures.
The two mentioned P5 light fixtures have been reduced to a single pole -
mounted light fixture and relocated to the west side of the property just north
of the dumpster enclosure and immediately south of the sidewalk access
connection from the adjacent property to the west, McDonald's Restaurant.
12. The landscape plan shows a possible P5 light fixture near the NE corner of the
trash enclosure. This is an important location for employee access to trash/
recycle enclosure. Would recommend deleting plant materials (DKL, RB) next to
this location in favor of low growing species (max. height 24")
Landscape plan in the previously mentioned area has been changed to
incorporate Rocky Mountain Sumac (2 to 3 feet high), Arcadia Juniper (1 �/2 to 2
feet high) and Buffalo Juniper (1 to 1 'h feet high.)
26. Please clarify how the swale that runs along the south, then east end of the site
will transition into the proposed curb and gutter on the east property line.
The swale shall terminate at the proposed 2 foot curb cut. The contractor shall
construct a 3 foot wide by 2 foot deep concrete cutoff wall at back of gutter.
20. Please clarify who will maintain the off -site pond. If it is to be maintained by the
overall developer (WW Reynolds), then a maintenance agreement should be
provided detailing how the pond will be maintained.
Maintenance of ponds is covered in Declaration of Covenants; we will provide
this with next submittal.
18. Please provide copies of off -site construction and drainage easements on Lot 1 of
the Tower Shoppes property. Letters of intent for these easements will be
required prior to this item going to a hearing.
Offsite easements are being provided with this submittal.
19. Temporary swales carrying drainage water into the pond have a history of siltation
and lack of proper maintenance. How will the Developer guarantee that these will
be properly maintained? A temporary (until Lot 1 develops) small diameter pipe
might be a good way to ensure that the area where water comes off the site drains
properly.
W.W. Reynolds has been and will continue to maintain the temporary drainage
swales as stated in the declaration of covenants. W.W. Reynolds is willing to
meet a City of Fort Collins Stormwater Representative in the field to come up
with a solution if desired.
13. With regards to the response to the conceptual review comments, specifically
number 16..."After consulting with planning staff, it was agreed that a reduction in
sidewalk width would be allowable as the sidewalk in question is not used as sa
path to the building." I do not believe that whether or not a sidewalk leads to a
building bears much on reducing the standard width as specified in 3.2.2 of the
LUC. Yes, this walkway would most likely not be used by patrons of the
establishment to reach the building. However, it seems to me that said walkway
would very likely be used by the "carhops"/servers to walk back and forth while
serving patrons of Sonic. If the walk is reduced in width, servers may very well be
forced to constantly walk in the drive aisle(s), behind parked vehicles, all the
while in conflict with arriving/departing vehicles. Unless there is a compelling
reason why the walk should be reduced to 7 feet, it seems that it would help
create a much safer pedestrian (worker) environment to keep the standard width
of 8 feet.
Walk changed to a width of 9 feet.
14. Include the standard general note pertaining to shrub/utility separation distance
on the landscape plans. Maintain the required landscape/utility separation
distance on the landscape plans.
Standard note added to landscape plans.
15. Make the text on the overall utility plan sheet pertaining to the abandonment of
the existing water service more legible.
Existing water service text now more legible.
16. Cleanouts are required every 100 feet on the proposed sanitary sewer service.
Clearly define those cleanouts with in vehicle travel areas as Traffic Rated and
include the standard detail on the detail sheet.
Cleanout separation provided. Note added per Traffic Rated cleanouts and
detail provided on detail sheet.
17. See site, landscape and utility plans for other comments.
Noted.
IL
3. Signage approved through separate sing permit application submittal thus signs
shown on this PDP not recognized as approval for such.
Signs removed from exterior elevations.
4. Landscape notes need to include that no Certificate of Occupancy or Temporary
Certificate of Occupancy can be issued with complete landscape installation or
securment by bond, escrow, or letter of credit in the amount of 125% of value of
uncompleted landscaping (materials/labor).
Noted. Missed in this submittal; will include in following submittal.