Loading...
HomeMy WebLinkAboutDAKOTA RIDGE PUD FIRST FILING PRELIMINARY - 60 91D - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSA, ITEM NO. 19 MEETING DATE 6/22/92 of Fort Collins PLANNING AND ZONING BOARD STAFF REPORT PROJECT: Dakota Ridge P.U.D., First Filing, Preliminary - #60-91D APPLICANT: CDL Partnership c/o Parsons and Associates 432 Link Lane Plaza Fort Collins, CO. 80524 OWNER: Timberline Partnership 1600 Specht Point Road Fort Collins, CO. 80525 PROJECT DESCRIPTION: This is a request for Preliminary P.U.D. for 66 single family lots on 24.56 acres. The site is located within the Pine Cone Overall Development Plan, north of Horsetooth Road, approximately 1/4 mile east of Timberline Road. The zoning is RP, Planned Residential. RECOMMENDATION: Approval with Condition EXECUTIVE SUMMARY: The request for Preliminary P.U.D. for Dakota Ridge, First Filing conforms to the Pine Cone O.D.P. Tract A is 4.81 acres and is shown as a future development area only. The project scores 75% on the Residential Uses Point Chart and satisfies the All Development criteria of the L.D.G.S. The single family land use is compatible with the surrounding area. Dakota Ridge Drive is classified as a local street. A variance from the strict requirements of the Solar Orientation Ordinance is recommended based on peculiar topographical and access conditions which would cause a hardship to the developer. A condition of approval is recommended in order to promote the intent of the Solar Orientation Ordinance. The transportation impacts are within the estimates established by the traffic analysis for the Pine Cone O.D.P. DEVELOPMENT SERVICES 300 LaPorte Ave. P.O. Box 580 Fort Collins, CO 80522-0580 (303) 221-0750 PLANNING DEPARTMENT PINECONE P.U.D. FIRST FILING STATEMENT OF PLANNING OBJECTIVES MAY 4, 1992 INTRODUCTION The Pinecone P.U.D. First Filing is a proposed residential development within the recently approved Pinecone Overall Development Plan (ODP). This 25 acre parcel is the first single family residential area presented to the City of Fort Collins within the ODP. The 66 single family lots are planned to be consistent with the goals and objectives of the Pinecone ODP and to be consistent with adopted City policies. The parcel is located within Planning Areas F, G, & H of the Pinecone ODP approved in April of 1992. This area is bounded by the proposed Fort Collins High School site on the west, Horsetooth Road and the existing Fox Meadows Subdivision on the south, the proposed Webster Farm Residential Development on the east and additional proposed Pinecone single family development on the north. GOALS City of Fort Collins planning goals and objectives met by the development of this single family project are as follows: 1. The creation of a successful single family neighborhood compatible with the surrounding development and the approved ODP. 2. The provision for logical transitions between the proposed residential neighborhoods and the existing adjacent developments. 3. The efficient utilization of existing infrastructure including streets, sewer, water, irrigation, drainage, gas, electrical, and telephone utilities. May 4; 1992 Page 2 of 3 Pinecone P.U.D. First Filing Statement of Planning Objectives 4. The creation of a site orientation which promotes opportunities for energy efficiency. 5. The provision of a system of bike and pedestrian paths that fit within the overall circulation system. OWNERSHIP OF PUBLIC AND PRIVATE OPEN SPACE In addition to the 66 lots two separate tracts are proposed. Tract "A" is a 4.81 acre parcel which will be developed by the owner in the future as cluster housing. Tract "B" is a 0.13 acre parcel which will be dedicated to the City of Fort Collins for utilities and a bike trail. It is intended that the City of Fort Collins maintain this area as part of the overall trail system. DESCRIPTION OF DESIGN RATIONALE The creation of five cul-de-sacs with ten to fifteen lots each allows for the development of private areas and larger unique lots. This layout provides for an average lot size of 9,563 square feet creating building sites that will accommodate a variety of housing opportunities. The east -west direction of four cul-de-sacs allows for access to the westerly open space created by the school campus including landscaped athletic fields, detention ponds and miscellaneous park and open areas. This street alignment results in 65% of the lots having a north -south orientation which insures conformance with the recently adopted City of Fort Collins Solar Orientation Ordinance. The main access road through the site provides a direct link with Horsetooth Road's major transportation and utility facilities. A narrower street section with detached sidewalks and trees will help control traffic speeds and provide an aesthetically pleasing amenity to May 4; 199,2 Page3of3 Pinecone P.U.D. First Filing Statement of Planning Objectives the area. Houses facing this roadway have views of landscaped areas to the west and the detached walks and narrower roadways will create an attractive streetscape. Bike and Pedestrian Trails as proposed in the Pinecone ODP are provided as part of this project. These trails will provide an important link between the commercial area, school and park proposed in the immediate vicinity. VARIANCES A variance from the 150 foot depth required of lots adjacent to arterials will be needed. This variance will be required for lots 5, 6 and 7. These lots have depths of 140 feet which is the result of the cul-de-sac configuration dictated by the overall layout. This impact is mitigated by fencing of the property line and landscaping between the lots and Horsetooth Road. A variance will also be needed for street widths throughout the P.U.D. The main entrance road has been reduced from a proposed collector section of a 50 foot width in a 68 foot right-of-way to a 36 foot width in a 54 foot right-of-way. This reduction is requested to help mitigate the "racetrack effect" created by full size collectors and to create a pleasing streetscape. Local streets have been reduced from 36 feet to 32 feet in width within a 54 foot wide right-of-way. LAND USE CONFLICT MITIGATION Pinecone P.U.D. First Filing follows the guideline and densities outlined by the approved ODP. As such, land use conflicts within the ODP are minimal. Uses along the eastern and southern edge of the ODP are also compatible with the low density single family development proposed and will not require special mitigation. TABLE 2 Trip Generation Daily A.M. Peak P.M. Peak Land Use Trips Trips Trips Trips Trips in out in out Parcel A Neighborhood Retail 7430 122 53 305 316 Center - 100 KSF Parcel B High School - 1800 students 5250 655 355 112 169 Parcel C Neighborhood Park. &_ _ _ _ 20Q _ -- 77 55 93 93 H.S. Athletic Fields Day Care - 100 students 700 63 - '56 62 67 Parcel D - C-store/gas & retail - 6KSF 3000 85 80 95 100 Multi -Family - 200 D.U. 1170 14 75 75 37 Parcel E Business Services - 4.3 Ac 2620 44 19 106 110 Parcel F Single Family - 22 D.U. 220 5 12 14 8 Parcel G Single Family - 60 D.U. 600 13 33 38 22 Parcel H Single Family - 40 D.U. 400 8 22 25 15 Parcel J Single Family - 30 D.U. 300 6 17 19 11 Parcel K Single Family - 36 D.U. 360 8 20 23 13 Parcel L Single Family - 22 D.U. 220 5 - 12 14 8 Parcel M Single Family - 72 D.U. 720 15 40 45 27 Parcel N Single Family - 85 D.U. 850 18 47 54 31 Parcel P Single Family - 160 D.U. 1600 34 88 101 59 �/NEConlb I DAKoT�.Id)GE Pu.A„ �/RsT C'/t/N�P�EL/M/NARY ALL DEVELOPMENT; NUMBERED CRITERIA CHART ALL CRITERIA APPLICABLE CRITERIA ONLY CRITERION is the criterion 0001ccble? Will the criterion be satistlea7 If no, please explain a e��.�' Yes No NEIGHBORHOOD COMPATABILITY 1. Social Comoatability 2. Neighborhood Character 3. Land Use Conflicts 4. Adverse Traffic Impact PLANS AND POLICIES 5. Comprehensive Plan PUBLIC FACILITIES & SAFETY 6. Street Capacity 7. Utility Capacity of 8. Design Standards 9. Emergency Access 10, Security Lighting 11. Water Hazards RESOURCE PROTECTION 12. Soils & Slobe Hazard of 13. Significant Vegetation 14. Wildlife Habitat 15. Historical LondmorK 16. Mineral Deposit 17. Eco-Sensitive Areas 18. Agricultural Lands ENVIRONMENTAL STANDARDS 19. Air Quality 20. Water Quality 21. Noise 22. Glare & Heat 23. Vibrations 24, Exterior Lighting I 25. Sewages & Wastes SITE DESIGN 26. Communrty Organization ✓ 27. Site Organization 000, 28. Natural Features 29. Energy Conservation o.-Ap, AA*q&%ffA"0ejGE 30.Shadows 31. Solar Access ✓ 32. Privacy voe 33. Open Space Arrangement 34, Building Height 35, Vehicular Movement 36. Vehicular Design 37. Parking 38. Active Recreational Areas A/ 39. Private Outdoor Areas 40. Pedestrian Convenience Pool 41. Pedestrian Conflicts 42. Landscaping/Open Areas 43. Lanciscaping/Buildings 44. LanascactngiScreening 45. Public Access 00, 46. Signs ACTIVITY: Residential Uses DEFINITION: H All residential uses. Uses would include single family attached dwellings, townhomes, duplexes, mobile homes, and multiple family dwellings; group homes; boarding and rooming houses; fraternity and sorority houses; nursing homes; public and private schools; public and non-profit quasi -public rec- reational..uses. as a princi,pal.use; uses providing meeting places and places for public assembly with incidental office space; and child care centers. CRITERIA' Each of the following applicable criteria must be answered "yes" and implemented within the develop- ment plan. Yes No 1. On a gross acreage basis, is the average residential density in the project at least three (3) dwelling units per acre (calculated for residential portion of the site only)? XX 2. DOES THE PROJECT EARN THE MINIMUM PERCENTAGE POINTS AS CALCULATED ON THE FOLLOWING "DENSITY CHART" FOR THE PROPOSED DENSITY OF THE RESI- DENTIAL PROJECT? THE REQUIRED EARNED CREDIT FOR A RESIDENTIAL PROJECT XX SHALL BE BASED ON THE FOLLOWING: ***30-40 PERCENTAGE POINTS = 3-4 DWELLING UNITS/ACRE;*** 40-50 PERCENTAGE POINTS = 4-5 DWELLING UNITS/ACRE; 50-60 PERCENTAGE POINTS = 5-6 DWELLING UNITS/ACRE; 60-70 PERCENTAGE POINTS = 6-7 DWELLING UNITS/ACRE; 70-80 PERCENTAGE POINTS = 7-8 DWELLING UNITS/ACRE; 80-90 PERCENTAGE POINTS = 8-9 DWELLING UNITS/ACRE; 90-100 PERCENTAGE POINTS = 9-10 DWELLING UNITS/ACRE; 100 OR MORE PERCENTAGE POINTS = 10 OR MORE DWELLING UNITS/ACRE. -29- DENSITY CHANT Maximum Ecrnec Criterion Credit If All Dwelling Units Are Within: Credit a . 20°0 . 2MOfeet ofone. uvorpaora eaneronoomooasmobvigp«tter Pi necone ODP) 20 b 10% 650tn°torane.nnngnanvnroa C - 10% d000 feet at on evsnng or aoorovearegrona smarting center. d 0 20% 3500feetoranenmrtqIXfesalveorognporrtooaoorlccommrmncon, «commwvtyiocnlfy. (Plnecone DDP) 20 . W a 10'a 1000 feefotascmameenrlg an tnereowrartsenrs of me comotusav eaut canon icr ct firm Slate ofCaoraao. 10 Qf 20010 700ofeet atamcaoremoroYmentcenter.(Public Service. PA & NEC 20 W 9 5% 10Cbfeefofaonto corecenter. Pi necone ODP 5 h 20 a, To n Fort cat rn I 20% iM Cenrta &a4trs 0imfct Aorolect wmw o0trr10ONisCOnnqufMlO Writing tXOan aet6lOOf1tenl. Crean mcy09 eamea M fotlow 0%—Fofcrolecsswrsosa orcoeMpounaom Ms 0 to 10%mnnguM. 10 to 15%—For sxaecRwnose,orocerNO°unaannps 10 to 20%ccnnguit . j 30% 15 to 20%—ForaaeCnwnose IXooeMoo aary nas 20 to 30%conriwty. 20 to 25%—For aratectswnose OrOOCM00UnaOryr1at 30 to 40%COnnWtr. 25 to 30%—For oroleaswros oroc env bounaaN not 40 to 50 <conngwM. 0dcan ceaemontrrareamot mevoiecfwllre B qn•reMweaOenergyuseogeelmefmrougnme, coaKSlnonofanernpmeenergy k mlems or mr°ugn commtneaenerglconsanvnon meeswes oevorsomatrom+aryreeurrea Ov ON Coce.a5% bonus may ce eomee ' for every 5% reptrcnon n energy tnfs. I Co:cu=e a 1%bonus for every 50 oaestnauaaa in me wolect. m Cciculote me oefcentage of me tc:of acres in me IXolecs mat are aevofeo to recreanon t use. enter V2 aft art aercentoge as a 00nuv n me aoalcent cemrvrs to oreserwy oeirmnent owe eoen sooce matmeers me GtV s minimum catcLActe me mfcentage n of mvsooen space aaepge fomarotaaeveroomentoaeaga.enterrtv: Defcenfpga osa oorluu n can of me iota eevelODmenr oumei e to ce scent onnegnaornooa orralc menvffocdlnes w cfn we not omfsr w teawree ovGNCepe. O enrer 2% ocims far every 5100 per c�ing t fmveaea uoortof me rotalaeveroarimtotnaern ro cescenron negnoornooptoavnes arse semceswnlrn pre notomenvlse repweawGNCxe. p enter al%bonus far every 51CO rwr c.ening unit nveaea IfacOmmrlrtrentn0etngribOe roCCVerOapSDeclhea OerCCNage of mBfOtOt numcef0l pwemnguMSlIX lawrnOomefamllies.elver mat 4 cefcenfogeascconmuofoart+cmulfrtat30%. nacOmmrtnentn DB�ngg fnepBfOOPrtleODSDeCIfiep DBlCentOgB of metOfal ruYitoef OfawellYtg Wvrs lIX fypB'A-Ond ryp0-8•tgnOICODaep Z ndavng ns pehnea cyme Ciryaf Fort Cauns mlculafe Ir>e oonuz oz falows; Or iyce -A-- 5 fines 7Tyne A M l t Type W —tA fines Tvoe B" unft loiatYurs In no toss Snit me cormema boN ate greater man30"d' n me vte or colatcenf voae confarn on historic t"Ong or 0locem o cons nnov ce eamect for me fOlrowvvj ]% — For orewenrrgormmganng ormcie nnuencesfa.germrpnrt+entpl bnatue. oesmene economic asp=01 laaonl Oaverw form S Oresenpnat: ]% — Fofcsw mm�ewsmr.amwrubetnveeangwnnmecnarocrerofinewilaingorbloce.w ile°wlaingtaalunm 7`.s —far arOOC'nq OacOnve tse ct m9 pnlprng of D�Oce mptwtll l¢Op lomcOnnNlOnce. pfeseNVnOn OnOlmOlwementln°n ' aDDfautaB rt+onner. IfcW on°rat Olme,e tfe pars/u7mmemumotera tlycra6Ctu IXOt'l vn efgrounQwmtnmed iongorInaneiew oomng 1T fWe esanecc i t famCtYUTON srtUCNre.O Dais rtu]ypo eamepas folio i t 0% — For otananq 75%IX more at m. caning in a smratsre. 0% —Fat IXOvpng 50-7d%Oftna ppfurtlg rnOStRCluO: - 3% — FOf Orw ng25-da%of"ccnrngmcsmKve. U rip COmmltmCN ROBlflg mope la Ofp�spe ODOfOvec L<mMfatlC fifO BYnngUltnlnlg Mrefrufa me awelhng UNR BnferOOOnUs of lO%. TOTAL 75 W a. x c� J W G W x H Q z MEMORANDUM 10 To: Jeff Couch, Parsons and Associates o From: Matt De l i ch Date: June 3, 1992 Subject: Street cross section for north/south Road A in Pinecone PUD (File: 9203MEM1) This memorandum addresses the traffic concerns pertaining to the north/south Road A in Pinecone PUD. This street intersects with Horsetooth Road at a "T" intersection'. The control at this intersection will be a stop sign on Road A: Figure 6 of the "Pinecone PUD Site Access Study," April, 1992 shows the expected peak hour traffic at this intersection. It is labelled intersection 8 on Figure 6, which is attached to this memorandum. Also attached to this memorandum is Figure 7 from the site access study, which shows the recommended long range geometrics. The expected peak hour traffic volumes are shown in Figure 6 (AM - 255, PM - 295). A two lane cross section will adequately handle this traffic. I recommend the striping at the intersection provide for one northbound lane and two, southbound lanes (a right -turn lane and a left -turn lane). This intersection approach lane configuration should extend to the north at least 100 feet or to a convenient transition point (e.g. at an intersection). The general cross section of Road A should have two travel lanes and two parking lanes. z This can be accomplished in a 36-40 foot wide street. The cc variation in width is determined by the width of the travel zlanes (101, 11' or 12'). The parking lanes should be 8 feet (D wide. Since there are detached bike paths proposed adjacent Z w to this street, it is recommended that bike lanes not be provided in the street itself. U • The bike paths diverge from Road A to the east through o Stone Ridge PUD and to the west toward the Fort Collins High School south parking lot. Since Horsetooth/Road A is a "T" o intersection, there is little need to take the bike lanes to N the intersection itself. The diverging bike path provides a a shorter route in a safer environment. Provision of additional °C bike lanes on the street will be an unnecessary duplication. LL I recommend that Road A be 36-40 feet wide with on -street a parking. Off-street bike paths should provide for the bicycle needs of the area residents. 4 N V W Z J CA: W m 2 s s Z40/15ri 0 \—so/Is IT) R-140 /I7,0 2 30/I20 -1 l 10/50—► I I [5/10S —"k, O�fi s N -9 AM / PM rounded to nearest 5 � o 0 o� n ~ - 25/10 — o kn ra goo oo� Ro^o A o$ s O tn 250/300 N f7N0N Qi-3s/5 _O tj A400/140 'J 1"/190 \20/�O r—el 1150� b3S1060 — 10/30 R5/1 �--515 1005 400/300-1 g60/1.80-0- 135/40 ,s/rto--/ 610/450—► HORSETOOTH ¢,0/t6o - ► b9S/54S —► o 400/360 �` m r- 9 Ns 00o x V r� 0 U Q' Q' LONG RANGE PEAK HOUR TRAFFIC Figure 6 l N v At IT RECOMMENDED LONG RANGE GEOMETRICS Figure 7 COMMENTS 1. Background The surrounding zoning and land uses are as follows: N: R-P; Vacant ("Low Density Residential" Pine Cone O.D.P.) S: R-L-P; Single Family (Fox Meadows Subdivision) E: R-L-P; Vacant (Stone Ridge O.D.P.) W: R-P; Vacant ("Low Density Residential" Pine Cone O.D.P., and New Fort Collins High School) This P.U.D. is part of larger parcel of land that was annexed into the City as the Timberline Second Annexation in 1979. It was originally zoned R-P with the P.U.D. condition. This P.U.D. condition was lifted by a rezoning request in 1981. The site was included in the Greenfield Village Master Plan which was in effect from 1981 to 1992. The Pine Cone O.D.P. was approved on April 27, 1992 and designated the subject site as "Low Density Residential". Two projects have been approved by the Planning and Zoning Board within (and around) Pine Cone O.D.P.: New Fort Collins High School - Site Plan Advisory Review Pine Cone Apartments - Preliminary P.U.D. 2. Context Within the Section: Dakota Ridge lies within a section that has been planned for Pine Cone O.D.P. (170 acres), New Fort Collins High School (68 acres) and Stone Ridge O.D.P. (92 acres). The remainder of the section is owned by C.S.U. and the Johnson Farm. The development of this section represents sequential growth on the urbanized eastern fringe. This growth follows the path of the existing, or designated, arterial streets. The designation of Timberline Road as a major arterial street, and its planned crossing of the Poudre River, represents a significant transportation element of the City's Master Street Plan, and allows easy, community -wide access to the section. A City neighborhood park has been purchased slightly north of Dakota Ridge served by the same street. This 15 acre park is contiguous to approximately 30 acres of high school athletic fields. The result is a large open space area that will buffer the residential areas from the intensity of the high school. This open space will also act as a "commons" and function as a recreational and visual amenity for the surrounding area. Dakota Ridge PUD, 1st Filing - Preliminary PUD, #60-91D June 22, 1992 P & Z Meeting Page 3 3. Land Use• A. Overall Development Plan Dakota Ridge is described by Parcel G and part of Parcel H on the Pine Cone O.D.P. These parcels are designated as "Low Density Residential". Since Dakota Ridge P.U.D. is a single family residential project, it is in conformance with the O.D.P. B. variable Criteria Dakota Ridge proposes to divide 66 single family lots on 24.56 acres. Out of this total, 4.81 acres are dedicated as Tract A and reserved for future "cluster" housing. Also, Tract B,.13 acre, is dedicated as drainage channel. By subtracting these areas from the total, the gross acreage is 19.62. This results in a gross density of 3.36 dwelling units per acre, and satisfies the requirement that residential density be a minimum of three dwelling units per acre. The project scores 75% on the Residential Uses Point Chart of the L.D.G.S. Points were awarded for proximity to the following: Neighborhood Shopping Center (Parcel A, Pine Cone O.D.P.) Neighborhood Park (Parcel C, Pine Cone O.D.P.) Public School (New F.C.H.S.) Major Employment (N.C.R., Platte River Power Authority, and Horsetooth Business Park) Child Care Center (Pine Cone O.D.P.) The score of 75% justifies the proposed density of 3.36 dwelling units per acre. 4. Neighborhood ComDatibilit A neighborhood information meeting was held on January 29, 1992 to discuss the entire Pine Cone O.D.P. The placing of low density residential in this area of the O.D.P. was considered acceptable. The consensus of citizen input was that the neighborhood park and athletic fields would act as a sufficient separation from the intensity of the new high school. As a single family project, the proposed P.U.D. is considered compatible with the surrounding area. 5. Design: Unlike typical sections, Dakota Drive will not need to be a collector but will be classified as a local street. This down- grading is based on the low volumes of traffic expected to be generated out of the southerly portion of Pine Cone O.D.P. Also, Dakota Ridge PUD, 1st Filing - Preliminary PUD, #60-91D June 22, 1992 P & Z Meeting Page 4 with a local street connection planned into Stone Ridge, traffic will have two outlets to Horsetooth Road. The P.U.D. has responded to the local classification by electing to front 14 lots directly onto Dakota. This will allow these lots to face the large open space provided by the high school athletic fields and not block this amenity with side or rear yard privacy fencing. Also, on the east side of Dakota Drive, the sidewalk has been detached allowing the placement of deciduous shade trees in a formal row fashion. The local street width, detached sidewalk, and street trees in the parkway are designed to create a "neo- traditional" appearance and create an immediate sense of character for the neighborhood. Along Horsetooth Road, a continuous row of deciduous shade trees will be planted at uniform intervals within the parkway strip. This will reflect the treatment along English Ranch Subdivision and Stone Ridge P.U.D. These street trees are intended to create a formal streetscape and add an aesthetic function to the City's arterial street. The fence along Horsetooth will be six feet in height, placed directly behind the sidewalk, and feature a combination of brick and wood. The exact specifications will be determined at the time of Final P.U.D. Fencing along the east property line will also be determined at the time of Final P.U.D. 6. Solar Orientation: The Solar Orientation Ordinance requires that 65% of the lots within a single family P.U.D. or subdivision be oriented within 30 degrees of a true east -west line. Dakota Ridge provides solar orientation for 36 lots, out of a total of 66, for 55% of the total. In order to gain 65% compliance, seven additional lots, for a total of 43, would need to be oriented to within 30 degrees. The applicant has submitted a variance request for relief from the strict requirement of 65% orientation requirement. The applicant's variance request is attached. In summary, the applicant states the following: A. For Lots 1 - 48, the site is constrained by existing boundary points creating a rectangular shape that is oriented north -south. The westerly boundary is Dakota Ridge Drive which has been located as far west as possible. Any further shifting to the west would cause severe developable hardship on Parcel F of Pine Cone O.D.P. Dakota Ridge PUD, 1st Filing - Preliminary PUD, #60-91D June 22, 1992 P & Z Meeting Page 5 The eastern boundary is the property line with Stone Ridge. The northerly property line (for Lots 1 - 48) is the drainage swale that will serve a regional drainage function and, therefore, be dedicated to the City's Stormwater Utility. The width of the swale to be dedicated has not been fully resolved but would likely not exceed 40 feet. The southerly boundary point is Horsetooth Road. Consequently, the rectangular shape creates a need to provide a series of east -west cul-de-sacs to gain solar orientation. These cul-de-sacs have been provided allowing the best possible orientation under the circumstances. For Lots 1 - 48, 35 lots, or 73%, are solar oriented. For the first 48 lots, if no lots fronted on Dakota Ridge Drive, two extra lots could be fronted on the east -west cul-de sacs raising solar compliance to 58%. This was not done to allow front yard exposure to the 30 acres of open space represented by the high school athletic fields. Since these fields are considered a visual amenity, and since Dakota Ridge Drive is a local street, it is the applicant's desire to not treat the streetscape with side yard privacy fences. Also, by fronting lots on Dakota Ridge Drive, the perception of neighborhood character is enhanced which contributes to lower speeds. B. For Lots 49 - 66, the boundaries again are determined by Dakota Ridge Drive, the regional drainage swale, and the local street connection into Stone Ridge O.D.P. Another series of east -west cul-de-sacs would turn its back on the 30 acres of high school athletic fields. In addition, the high school athletic fields and City neighborhood park will be irrigated by raw water stored in a series of retention ponds that will flank Dakota Ridge Drive on the west. The desire to front onto Dakota Ridge to take advantage of the water views motivates the applicant to orient Lots 49 - 55 on a north -south line versus an east -west line. According to the Solar Orientation ordinance: "When permitted, the Planning and Zoning Board may authorize variances under this Article upon its finding that the following requirements in (1), (2), or (3) have been satisfied:" 11(1) That by reason of exceptional topographical, soil, or other subsurface conditions or other conditions peculiar to the Dakota Ridge PUD, 1st Filing - Preliminary PUD, #60-91D June 22, 1992 P & Z Meeting Page 6 site, hardship would be caused to a subdivider by the strict application of any provision of this Article." 11(2) That by reason of exceptional conditions or difficulties with regard to solar orientation or access, hardship would be caused to a subdivider by the strict application of any provision of this Article." 81(3) The applicant demonstrates that the plan as submitted is equal to or better than such plan incorporating the provision for which a variance is requested". Staff finds that the variance request is justified under the three requirements specified by the Solar Orientation Ordinance: Requirement (1): The site contains a regional drainage channel that, at the time of Final platting, could range in width from 20 to 40 feet. This channel has been identified by Stormwater Utility on a Master Drainage Basin plan as being a necessary improvement to convey developed flows to the designated outfall. Since this channel will be dedicated to the City as part of the regional system, it will remain intact after development. Requirement (2): There are difficulties with regard to access and the ability to provide for solar orientation. Dakota Ridge Drive is aligned to provide access to both Parcels F and G of the Pine Cone O.D.P. Any major shifting, to gain more east -west width, would cause severe hardship on the remaining undeveloped parcel. Given the existing rectangular layout, the subdivider has done the best possible job in providing solar orientation with a series of short east -west cul-de-sacs. Requirement (3): The site has the unique ability to be served by a local street (36 feet wide) off Horsetooth Road versus a collector street (50 feet wide). This allows for creation of enhanced neighborhood character with less amount of pavement and slower speeds. Also, the open space and visual amenities provided by the athletic fields and water retention ponds are unique and should be considered in overall site design. The applicant has accounted for this streetscape by detaching the local street sidewalk by 5.5 feet and planting a formal row of deciduous shade trees. These design features are an exciting departure from standard development practices and render the plan equal to or better than a plan Dakota Ridge PUD, 1st Filing - Preliminary PUD, #60-91D June 22, 1992 P & Z Meeting Page 7 featuring a 50 foot wide collector street, attached sidewalks, with side or rear yard privacy fences. In summary, Staff finds the request for a variance to allow only 55% of the lots to be oriented within 30 degrees of a true east - west line to be justified. Because of the existing storm drainage channel, the given north -south rectangular configuration, and the pre -determined alignment of Dakota Ridge Drive, requiring the 65% solar orientation would result in a hardship to the subdivider. Finally, Staff finds granting of the variance would not be a detriment to the public good or impair the intent of the Solar Orientation Ordinance but allows other public objectives to be part of the overall design. In order to promote the intent of the Solar Orientation Ordinance, Staff recommends the following condition: At the time of Final, for only seven lots necessary to reach 65% compliance, the applicant shall provide additional techniques to accomplish the intent of the Solar Orientation Ordinance. Such techniques include, but are not limited to, maximizing glazing on the southern exposure, placing garages on the north side of the structure, or siting the structure on the lot so that the home itself is within 30 degrees of a true east -west line. such techniques shall be demonstrated on the Final P.U.D. 7. Transportation: Single family development on Parcels G and H of the Pine Cone O.D.P. were evaluated for traffic impacts based on the analysis submitted and accepted for Pine Cone Farm O.D.P. In the Site Access Study (Delich, 1992) for Pine Cone Farm, Parcel G was estimated to contain 60 dwelling units. Dakota Ridge, in the area defined by Parcel G, contains only 45 dwelling units. In the Site Access Study, Parcel H was estimated to have 40 dwelling units. Dakota Ridge utilizes about one-half of Parcel H and contains 18 dwelling units. Therefore, the proposed number of dwelling units have been appropriately factored into the traffic analysis that was reviewed and evaluated by the Transportation Department during the deliberation for Pine Cone O.D.P. Based on the proposed density, Dakota Ridge is feasible from a traffic engineering standpoint. RECOMMENDATION: Two actions are required in order to approve Dakota Ridge, First Filing, Preliminary P.U.D. Dakota Ridge PUD, 1st Filing - Preliminary PUD, #60-91D June 22, 1992 P & Z Meeting Page 8 1. Variance to the Requirements for Solar Orientation Staff recommends granting a variance from the strict requirement that 65% of the lots be oriented to within 30 degrees of a true east/west line. The granting of this variance is based on: A. Because of an exceptional topographical condition peculiar to the site, hardship would be caused to the subdivider by the strict application of the Solar Orientation Ordinance. B. Because of an exceptional difficulty with regard to access, hardship would be caused to the subdivider by the strict application of the Solar Ordinance. C. Because the applicant has demonstrated there are unique site and design features incorporated into the plan, and because the granting of the variance would not cause a detriment to the public good, the variance is justified. 2. Approval Staff finds that the request for Dakota Ridge, First Filing, Preliminary P.U.D., is in conformance with the Pine Cone O.D.P. The proposed density is justified by a score of 750 on the Residential Uses Point Chart of the L.D.G.S. The All Development Criteria of the L.D.G.S. have been satisfied. Staff, therefore recommends approval of Dakota Ridge, First Filing, Preliminary P.U.D., #60-91D, subject to the following condition: At the time of Final, for only seven lots necessary to reach 65% compliance, the applicant shall provide additional techniques to accomplish the intent of the Solar Orientation Ordinance. Such techniques may include, but are not limited to, maximizing glazing on the southern exposure, placing garages on the north side of the structure, or sitting the structure on the lot so that the home itself is within 30 degrees of a true east -west line. Such techniques shall be demonstrated on the Final P.U.D. I I II ! II ♦♦ �,i i �; 11 ♦♦ i ■ i9 120 m� ♦ zo ■ OR.KE .1 lou.rv3 if ao aY Z� 37 RL � � i I ■ ■ Lu z ILI �a114ip1 ��a� !>ti�sm t'E o or l Cok 'L. 0 vurre .vivE.� sioRSEroonH ,� ,_ I • RLP d� I RL W o✓� r no mmummmm RLP 27I1n■ ITEM: DAKOTA RIDGE, I st Filing - Prel. NUMBER: 60-9 l D