Loading...
HomeMy WebLinkAboutPSD PROSPECT SCHOOL SITE - FDP200003 - DOCUMENT MARKUPS - ROUND 3 - STREET RELATED DOCUMENT (3)PH SC H2O PROSPECT ROAD INTERSTATE 25 COUNTY ROAD 5 E. MULBERRY STREET 52' FL-EOP w/ DETACHED SIDEWALK ON NORTH SIDE (PER LCUASS DETAIL 7-2F 1 2 STREET SECTION) PROSPECT ROAD - PROPOSED SECTION 15' UTIL ESMT 8' WALK 10' PKWY 6' BIKE LANE 11' TRAVEL LANE 12' MEDIAN/ TURN LANE 54' ROADWAY (FL-EOP) 87.5' RIGHT-OF-WAY (MIN.) 8' BIKE LANE 12' TRAVEL LANE 57.5' SECTION LINE TO PROPOSED ROW 30' 1 2 ROW (MIN.) 76' FL-FL w/ 8' ATTACHED (SOUTH) AND DETACHED (NORTH) SIDEWALKS (MODIFIED LCUASS DETAIL 7-2F) PROSPECT ROAD - ULTIMATE SECTION (4-LANE ARTERIAL) 8' WALK 10' PKWY 11' TRAVEL LANE 11' TRAVEL LANE 5' BIKE LANE 76' ROADWAY (FL-FL) 8' WALK 107.5' ROW 3' BIKE LANE BUFFER 11' TRAVEL LANE 11' TRAVEL LANE 5' BIKE LANE 3' BIKE LANE BUFFER 3' BIKE LANE BUFFER MATCH EXISTING 12' TURN LANE LEFT TURN MEDIAN 4' MEDIAN 15' UTIL ESMT 15' UTIL ESMT 2' ACCESS ESMT A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Drainage Report for PSD Middle School High School #2 dated March 6, 2020 by Northern Engineering shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 53 CS3 UTILITY NOTES 3 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R CITY OF GREELEY The City's acceptance shall not relieve the design engineer's responsibility for errors, omissions, or design deficiencies for which the City is held harmless. C. CITY OF GREELEY NOTES: 1. All easements and Rights-of-Way crossing the City of Greeley Easement are subject to the rights of said City of Greeley Easement. 2. There shall be no permanent structures, concrete slabs, detention ponds, fences, walls, trees, or other landscaping or berms greater than 3 feet at mature growth, or other obstructions within the City of Greeley Easement. no cover shall be removed and/or added without written permission from City of Greeley Water Engineer. 3. There shall be no other utilities within the City of Greeley Easement except at right angle crossings and unless previously approved by the City of Greeley Water & Sewer Department. All plans shall be submitted during the design phase at least two weeks prior to construction and shall show potholed locations and elevations in plan and profile view. Greeley Water & Sewer will issue appropriate crossing approval. 4. In the event that excavation is required for the City of Greeley water pipelines due to water pipeline repairs, replacement or other operations, the excavation will be backfilled safely but surface restoration will not be done by/ or at the expense of the City of Greeley. 5. Greeley water pipeline locations are approximate, contact Keith Ikenouye at 970 371-3718 72 hours in advance of any locate request or any construction activities within the Greeley Water Pipeline Easement. 6. There shall be no vibratory or heavy sheepsfoot compaction within 20 feet of the existing water transmission pipeline. Static compaction equipment shall be used. 7. Greeley pipelines are to have a minimum of six (6) feet of cover at all locations to be used as a land bridge during any construction activities. 8. Greeley water line support at crossings shall be incorporated into the design if proposed utility crossing is below the water line using open trench construction. 9. Any irrigation lines and/or sprinkler systems located within Greeley Easement requires contractor to provide Greeley a full set of landscaping & irrigation/sprinkler system plans for review and approval. Plans to be provided a minimum of 2 weeks prior to construction. Valve boxes are not to be located within Greeley's Easement. 10. Any work to be done on City of Greeley waterline(s) shall conform to current City of Greeley Specifications. SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G G G G G G G G CTV CTV CTV CTV CTV CTV X X X CTV CTV CTV CTV CTV CTV CTV OHU CTV CTV CTV CTV X X CTV CTV CTV CTV CTV CTV X X CTV CTV CTV / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G G G G / / / / / / / / X X X X X / / / / / / / / CTV X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU SS SS SS SS SS SS SS SS SS W W G G G / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / OHU OHU OHU OHU B M C S GAS C WV B M / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / B M WV W S O VAULT F.O. VAULT VAULT CABLE F.O. C VAULT F.O. F.O. CABLE CABLE TELE CABLE CABLE TELE W M M M M M GAS F.O. F.O. VAULT CABLE F.O. F.O. SS FO FO FO FO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W G G G G G G G G G G G G G G G G G G G G G G G CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV X X X CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV X X CTV CTV CTV CTV CTV CTV CTV OHU OHU S S H2O H2O H2O H2O H2O H2O WV WV W S C M CABLE C M W W CC E W W W W G G G G G G G G G G G G G G G G G G G G G G G CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV X X X CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV X X CTV CTV CTV CTV CTV CTV CTV SS SS SS SS SS SS SS SS SS SS SS SS SS SS OHU OHU S S H2O H2O H2O H2O H2O H2O WV WV W S C M CABLE C SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS CTV CTV CTV CTV CTV CTV CTV G G G G G G G G G G G G G G G G G G G G G G X X X CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU S S S S MM C W M CABLE CABLE CABLE CABLE CABLE VAULT CABLE CABLE M CABLE C WV MH MH 8" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CTV CTV CTV CTV CTV CTV CTV G G G G G G G G G G G G G G G G G G G G G G X X X CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU S S S S MM C W M CABLE CABLE CABLE CABLE CABLE VAULT CABLE CABLE M CABLE C WV MH MH 8" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS G G G G G G G G G G G G G G G G CTV X OHU OHU OHU OHU OHU OHU OHU OHU S S S C C GAS C C WV C WV WV W S O VAULT F.O. VAULT CABLE C CABLE CABLE CABLE TELE W GAS VAULT CABLE F.O. F.O. SS FO FO FO FO FO FO E T T T T G G G G G G G G G G G G G G G G CTV X SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS OHU OHU OHU OHU OHU OHU OHU OHU S S S C C GAS C C WV C WV SS SS SS SS WV W S O VAULT F.O. VAULT CABLE C CABLE CABLE CABLE TELE W GAS VAULT CABLE F.O. F.O. SS FO FO FO FO FO FO E T T T T T T T T T T FO FO FO FO FO FO FO FO FO FO FO FO FO G G G G FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO CTV CTV CTV CTV T T T T T T T T T G G G G G MH W W OHE OHE W W W W W G WV W W W W W W G 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / STA.=43+25.53 CONNECT TO EXISITNG w/ 12"X12" CROSS w/ TB 1-12" BFV (W), 12"x2" REDUCER (S), & 12"x8" REDUCER (E) 73' FL-EOA 97.5' PROPOSED ROW EXISTING GAS LINE EXISTING GAS LINE 15' UTILITY EASEMENT 8' SIDEWALK 81' DITCH EASEMENT 30' BOXELDER SANITARY EASEMENT PROSPECT ROAD MAIN STREET CARRIAGE ROAD STORM DRAIN (SEE NOTE #14) EXISTING 15" PVC SANITARY SEWER (BOXELDER) TIMNATH RESERVOIR INLET CANAL APPROXIMATE LOCATION EXISTING 8" WATER STORM DRAIN (SEE NOTE #14) APPROXIMATE LOCATION EXISTING 2" WATER 24" STEEL CASING PIPE (SEE NOTE #14) APPROXIMATE LOCATION EXISTING 2" WATER STA.=41+13.89 ARV 91.96 LF 12" PVC S89°59'09"E 79.92 LF 12" PVC S89°59'09"E 22.63 LF 12" PVC S44°59'09"E 17.13 LF 12" PVC S89°59'09"E STA.=41+93.81 12"X6" SWIVEL TEE w/TB FH ASSEMBLY & 6" GV (N) 442.88 LF 12" PVC S89°59'09"E 629.84 LF 12" PVC S89°59'09"E FIRE HYDRANT N:123599.14 E:221036.13 STA.=42+85.77 45° BEND w/TB STA.=43+08.40 45° BEND w/TB 12'x6' RCBC (TRIC) SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 76.93 LF 8" PVC N00°38'58"E RYAN JEFFREY L/SYBIL A 1601 CARRIAGE RD KNIEVEL JANET A 5001 E PROSPECT RD LACY KEITH W JR 1601 S COUNTY ROAD 5 TRACT C SERRATOGA FALLS 2ND FILING POUDRE SCHOOL DISTRICT HEBBELN JAMES E/DEBRA S 1647 ENCHANTMENT DR STA.=36+71.01 12"X8" TEE w/TB 1-12" BFV (E), 1-8" GV (S) TIE TO EXISTING 4" WATER LINE w/ 8"x4" REDUCER RELOCATE EXISTING VALVE AS NEEDED N:123508.09 E:220511.94 4895 4900 4905 4910 4915 4920 4925 4930 4935 4895 4900 4905 4910 4915 4920 4925 4930 4935 33+50 34+00 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 4916.85 4916.24 4916.28 4916.78 4917.32 4917.91 4918.50 4918.97 4918.75 4918.72 4917.00 4916.69 4916.54 4916.39 4916.13 4916.06 4916.16 4916.40 4916.53 4916.66 4916.91 4917.04 4917.17 4917.46 4917.61 4917.76 4918.05 4918.20 4918.35 4918.64 4918.79 4918.90 4918.98 4918.95 4918.88 4918.62 4918.57 4918.57 4918.60 12" PVC 12" PVC 12" PVC 12" PVC STA. 43+25.5 CONNECT TO EXISITNG w/ 12"X12" CROSS w/ TB 1-12" BFV (W), 12"x2" REDUCER (S), & 12"x8" REDUCER (E) T.O.P.=4913.69 STA. 36+71.0 0.0° DEFLECTION T.O.P.=4912.18 STA. 35+94.2 0.3° DEFLECTION T.O.P.=4911.72 STA. 36+71.01 12"X8" TEE w/TB 1-12" BFV (E), 1-8" GV (S), & 8"x4" REDUCER (S) T.O.P.=4912.18 STA. 42+85.77 45° BEND w/TB T.O.P.=4913.79 STA. 43+08.40 45° BEND w/TB T.O.P.=4913.73 STA. 41+13.89 ARV T.O.P.=4914.29 STA. 41+93.81 12"X6" SWIVEL TEE w/TB FH ASSEMBLY & 6" GV (N) T.O.P.=4914.03 100.7' DEF. STA. 40+79.58 T.O.P.=4914.24 STA. 41+80.25 T.O.P.=4914.06 (@ 0.1°) PROPOSED GROUND EXISTING GROUND TOP OF PIPE PROPOSED GROUND Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 45 NORTH WT3 PLAN & PROFILE 12" WATER LINE - PROSPECT ROAD 8 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 KEYMAP P P C.O. G 1 2 3 4 5 4 3 2 1 0 G G 1 0 2 0 3 0 4 0 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 G 1 2 3 4 5 4 3 2 1 0 G G 1 2 3 4 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT RD MAIN STREET TRIC WT1 WT2 WT3 12" WATER LINE-PROSPECT RD PROFILE SCALE: LINE MATCH STA 33+50 MATCH LINE SEE SHEET C201 STA 33+50 SS W EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 8. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 9. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE. 10. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITHIN THE EXISTING 50' GAS LINE EASEMENT WITH MAGELLAN PIPELINE CO. AND COMPLY WITH ALL MAGELLAN PIPELINE CO. CRITERIA. 11. ALL TEES AND CROSSES SHALL USE FOSTER ADAPTERS AND MEGALUGS. 12. CONTRACTOR TO USE 11.25° BEND(S) WITH ALL JOINTS RESTRAINED 5-FT BOTH SIDES OF BEND, IF REQUESTED DURING CONSTRUCTION BY ELCO FIELD INSPECTOR (BASED ON SITE CONDITIONS). 13. CONTRACTOR TO COORDINATE LOCATION OF RELOCATED SERVICE TAPS AND METERS WITH ELCO FIELD STAFF AND CONNECT TO EXISTING HOME'S SERVICE LINE. 14. SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 G E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING GAS EXISTING SANITARY SEWER PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED LOT LINE PROPOSED WATER MAIN W EXISTING OVERHEAD UTILITY OHU EXISTING TELEPHONE T EXISTING CABLE CTV City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner UTILITY PLAN REVIEW EAST LARIMER COUNTY WATER DISTRICT T T T T T T FO FO FO FO FO FO FO FO FO FO FO FO FO G G G G FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO CTV CTV CTV CTV T T T T T T T T T G G G G G MH W W OHE OHE W W W W W G WV W W W W W W G 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / STA.=43+25.53 CONNECT TO EXISITNG w/ 12"X12" CROSS w/ TB 1-12" BFV (W), 12"x2" REDUCER (S), & 12"x8" REDUCER (E) 72' FL-FL 97.5' PROPOSED ROW EXISTING GAS LINE EXISTING GAS LINE 15' UTILITY EASEMENT 8' SIDEWALK 81' DITCH EASEMENT 30' BOXELDER SANITARY EASEMENT PROSPECT ROAD MAIN STREET CARRIAGE ROAD STORM DRAIN (SEE NOTE #14) EXISTING 12" PVC SANITARY SEWER (BOXELDER) TIMNATH RESERVOIR INLET CANAL APPROXIMATE LOCATION EXISTING 8" WATER STORM DRAIN (SEE NOTE #14) APPROXIMATE LOCATION EXISTING 2" WATER 24" STEEL CASING PIPE (SEE NOTE #14) APPROXIMATE LOCATION EXISTING 2" WATER STA.=41+13.89 ARV 80.17 LF 12" PVC S89°59'09"E 91.71 LF 12" PVC S89°59'09"E 22.63 LF 12" PVC S44°59'09"E 17.13 LF 12" PVC S89°59'09"E STA.=42+05.60 12"X6" SWIVEL TEE w/ FH ASSEMBLY & 6" GV (N) 442.88 LF 12" PVC S89°59'09"E 629.84 LF 12" PVC S89°59'09"E FIRE HYDRANT N:123599.13 E:221047.93 STA.=42+85.77 45° BEND w/TB STA.=43+08.40 45° BEND w/TB 12'x6' RCBC (TRIC) SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 76.93 LF 8" PVC N00°38'58"E RYAN JEFFREY L/SYBIL A 1601 CARRIAGE RD KNIEVEL JANET A 5001 E PROSPECT RD LACY KEITH W JR 1601 S COUNTY ROAD 5 TRACT C SERRATOGA FALLS 2ND FILING POUDRE SCHOOL DISTRICT HEBBELN JAMES E/DEBRA S 1647 ENCHANTMENT DR STA.=36+71.01 12"X8" TEE w/TB 1-12" BFV (E), 1-8" GV (S) CONNECT TO EXISTING 4" WATER LINE w/ 8"x4" REDUCER RELOCATE EXISTING VALVE AS NEEDED N:123508.09 E:220511.94 PROPOSED 15" RCP CULVERT EXISTING 8" WATER 4895 4900 4905 4910 4915 4920 4925 4930 4935 4895 4900 4905 4910 4915 4920 4925 4930 4935 33+50 34+00 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 4916.85 4916.24 4916.28 4916.79 4917.32 4917.91 4918.50 4918.97 4918.75 4918.72 4917.00 4916.69 4916.39 4916.13 4916.06 4916.16 4916.40 4916.53 4916.66 4916.91 4917.04 4917.17 4917.46 4917.61 4917.76 4918.05 4918.20 4918.35 4918.64 4918.79 4918.90 4918.98 4918.95 4918.88 4918.61 4918.46 4918.53 4918.56 12" PVC 12" PVC 12" PVC 12" PVC STA. 43+25.5 CONNECT TO EXISITNG w/ 12"X12" CROSS w/ TB 1-12" BFV (W), 12"x2" REDUCER (S), & 12"x8" REDUCER (E) T.O.P.=4913.69 STA. 36+71.0 0.0° DEFLECTION T.O.P.=4912.18 STA. 35+94.2 0.3° DEFLECTION T.O.P.=4911.72 STA. 36+71.01 12"X8" TEE w/TB 1-12" BFV (E), 1-8" GV (S), & 8"x4" REDUCER (S) T.O.P.=4912.18 STA. 42+85.77 45° BEND w/TB T.O.P.=4913.79 STA. 43+08.40 45° BEND w/TB T.O.P.=4913.73 STA. 41+13.89 ARV T.O.P.=4914.29 STA. 42+05.60 12"X6" SWIVEL TEE w/ FH ASSEMBLY & 6" GV (N) T.O.P.=4914.00 100.7' DEF. STA. 40+79.58 T.O.P.=4914.24 STA. 41+80.25 T.O.P.=4914.06 (@ 0.1°) PROPOSED GROUND EXISTING GROUND TOP OF PIPE PROPOSED GROUND Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 53 NORTH WT3 PLAN & PROFILE 12" WATER LINE - PROSPECT ROAD 9 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 KEYMAP C.O. G 1 2 3 4 5 4 3 2 1 0 G G 1 0 2 0 3 0 4 0 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 G 1 2 3 4 5 4 3 2 1 0 G G 1 2 3 4 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT RD MAIN STREET TRIC WT1 WT2 WT3 12" WATER LINE-PROSPECT RD PROFILE SCALE: LINE MATCH STA 33+50 MATCH LINE SEE SHEET WT2 STA 33+50 SS W EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 8. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 9. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE. 10. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITHIN THE EXISTING 50' GAS LINE EASEMENT WITH MAGELLAN PIPELINE CO. AND COMPLY WITH ALL MAGELLAN PIPELINE CO. CRITERIA. 11. ALL TEES AND CROSSES SHALL USE FOSTER ADAPTERS AND MEGALUGS. 12. CONTRACTOR TO USE 11.25° BEND(S) WITH ALL JOINTS RESTRAINED 5-FT BOTH SIDES OF BEND, IF REQUESTED DURING CONSTRUCTION BY ELCO FIELD INSPECTOR (BASED ON SITE CONDITIONS). 13. CONTRACTOR TO COORDINATE LOCATION OF RELOCATED SERVICE TAPS AND METERS WITH ELCO FIELD STAFF AND CONNECT TO EXISTING HOME'S SERVICE LINE. 14. EXISTING INFORMATION FOR TIMNATH RESERVOIR INLET CANAL, DATED DECEMBER 19, 2019, IMPROVEMENTS BASED ON DESIGN INFORMATION ONLY AND HAVE NOT BEEN SURVEYED. CONTRACTOR TO VERIFY RELEVANT INFORMATION PRIOR TO CONSTRUCTION. 15. THIS PROJECT IS TO BE CONSTRUCTED CONCURRENTLY WITH THE UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2. REFER TO UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2 FOR ADDITIONAL INFORMATION. 16. EXISTING 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE REMOVED BY EAST LARIMER COUNTY WATER DISTRICT DUE TO HAZARDOUS MATERIAL. CONTRACTOR'S DEMOLITION RESPONSIBILITIES FOR THE 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE LIMITED TO EXPOSING THE PIPE. CONTRACTOR SHALL COORDINATE ALL WATER LINE'S DEMOLITION ACTIVITIES WITH EAST LARIMER COUNTY WATER DISTRICT G E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING GAS EXISTING SANITARY SEWER PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED LOT LINE PROPOSED WATER MAIN W EXISTING OVERHEAD UTILITY OHU EXISTING TELEPHONE T EXISTING CABLE CTV City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner UTILITY PLAN REVIEW EAST LARIMER COUNTY WATER DISTRICT / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / STA.=30+41.16 12"X8" TEE w/TB 1-12" BFV (E), 1-8" GV (S), 56' FL-EOA 107.5' PROPOSED ROW ±24' OF SERVICE TO BE EXTENDED WITH 2" HDPE CASING EXISTING GAS LINE STA.=23+21.60 12"X8" TEE w/TB 1-12" BFV (E) & 1-8" GV (N) TEMP FH w/ 8"x6" REDUCER T.O.P. ELEV: 4911.54 N:123615.35 E:219163.93 719.57 LF 12" PVC S89°59'09"E 15' UTILITY EASEMENT 8' SIDEWALK 81' DITCH EASEMENT 30' BOXELDER SANITARY EASEMENT 629.84 LF 12" PVC S89°59'09"E MEADOWAIRE DRIVE PROSPECT ROAD EXISTING 15" PVC SANITARY SEWER (BOXELDER) STORM DRAIN (SEE NOTE #14) 20" STEEL CASING PIPE (SEE NOTE #14) 97.5' PROPOSED ROW 560.25 LF 12" PVC S89°59'09"E 12'x6' RCBC (TRIC) SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 79.97 LF 8" PVC N00°12'06"E TIE TO EXISTING 4" WATER LINE w/ 8"x4" REDUCER RELOCATE EXISTING VALVE AS NEEDED N:123505.20 E:219883.21 30.00 LF 8" PVC S00°00'48"W 8" WATER LINE (SEE ONSITE PLANS) NICHOLS LIVING TRUST 1601 MEADOWAIRE DR EKBLAD LARRY R/LINDA M 4725 E PROSPECT RD SPLITTGERBER RICHARD P/MEREDITH JEAN 1600 MEADOWAIRE DR POUDRE SCHOOL DISTRICT 4895 4900 4905 4910 4915 4920 4925 4930 4935 4895 4900 4905 4910 4915 4920 4925 4930 4935 21+50 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 33+50 4918.05 4918.25 4917.80 4917.25 4916.72 4916.78 4917.31 4917.86 4918.40 4918.46 4917.97 4917.45 4917.91 4918.17 4918.24 4918.27 4918.19 4918.08 4917.94 4917.66 4917.53 4917.39 4917.11 4916.98 4916.84 4916.61 4916.55 4916.66 4916.90 4917.04 4917.18 4917.45 4917.59 4917.73 4918.00 4918.14 4918.28 4918.49 4918.52 4918.51 4918.36 4918.23 4918.10 4917.84 4917.71 4917.58 4917.30 12" PVC STA. 30+41.16 12"X8" TEE w/TB 1-12" BFV (E), 1-8" GV (S) T.O.P.=4911.55 STA. 23+21.60 12"X8" TEE w/TB 1-12" BFV (E) & 1-8" GV (N) T.O.P.=4911.33 PROPOSED GROUND EXISTING GROUND TOP OF PIPE PROPOSED GROUND Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 45 NORTH WT2 PLAN & PROFILE 12" WATER LINE - PROSPECT ROAD 7 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 KEYMAP P P C.O. G 1 2 3 4 5 4 3 2 1 0 G G 1 0 2 0 3 0 4 0 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 G 1 2 3 4 5 4 3 2 1 0 G G 1 2 3 4 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT RD MAIN STREET TRIC WT1 WT2 WT3 12" WATER LINE-PROSPECT RD PROFILE SCALE: MATCH LINE SEE SHEET C202 STA 33+50 LINE MATCH STA 33+50 MATCH LINE SEE SHEET C200 STA 21+50 LINE MATCH STA 21+50 SS W EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 8. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 9. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE. 10. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITHIN THE EXISTING 50' GAS LINE EASEMENT WITH MAGELLAN PIPELINE CO. AND COMPLY WITH ALL MAGELLAN PIPELINE CO. CRITERIA. 11. ALL TEES AND CROSSES SHALL USE FOSTER ADAPTERS AND MEGALUGS. 12. CONTRACTOR TO USE 11.25° BEND(S) WITH ALL JOINTS RESTRAINED 5-FT BOTH SIDES OF BEND, IF REQUESTED DURING CONSTRUCTION BY ELCO FIELD INSPECTOR (BASED ON SITE CONDITIONS). 13. CONTRACTOR TO COORDINATE LOCATION OF RELOCATED SERVICE TAPS AND METERS WITH ELCO FIELD STAFF AND CONNECT TO EXISTING HOME'S SERVICE LINE. 14. SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 G E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING GAS EXISTING SANITARY SEWER PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED LOT LINE PROPOSED WATER MAIN W EXISTING OVERHEAD UTILITY OHU EXISTING TELEPHONE T EXISTING CABLE CTV City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner UTILITY PLAN REVIEW EAST LARIMER COUNTY WATER DISTRICT / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 8" SS STA.=30+41.16 12"X8" TEE w/TB 1-12" BFV (E), 1-8" GV (S), 54' FL-EOA 107.5' PROPOSED ROW ±24' OF SERVICE TO BE EXTENDED WITH 2" HDPE CASING EXISTING GAS LINE STA.=23+21.60 12"X8" TEE w/TB 1-12" BFV (E) & 1-8" GV (N) TEMP FH w/ 8"x6" REDUCER T.O.P. ELEV: 4911.54 N:123615.35 E:219163.93 719.57 LF 12" PVC S89°59'09"E 15' UTILITY EASEMENT 8' SIDEWALK 81' DITCH EASEMENT 30' BOXELDER SANITARY EASEMENT 629.84 LF 12" PVC S89°59'09"E MEADOWAIRE DRIVE PROSPECT ROAD EXISTING 12" PVC SANITARY SEWER (BOXELDER) STORM DRAIN (SEE NOTE #14) 20" STEEL CASING PIPE (SEE NOTE #14) 97.5' PROPOSED ROW 560.25 LF 12" PVC S89°59'09"E 12'x6' RCBC (TRIC) SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 79.97 LF 8" PVC N00°12'06"E CONNECT TO EXISTING 4" WATER LINE w/ 8"x4" REDUCER RELOCATE EXISTING VALVE AS NEEDED N:123505.20 E:219883.21 30.00 LF 8" PVC S00°00'48"W NICHOLS LIVING TRUST 1601 MEADOWAIRE DR EKBLAD LARRY R/LINDA M 4725 E PROSPECT RD SPLITTGERBER RICHARD P/MEREDITH JEAN 1600 MEADOWAIRE DR POUDRE SCHOOL DISTRICT 8" WATER LINE (SEE NOTE #15) 4895 4900 4905 4910 4915 4920 4925 4930 4935 4895 4900 4905 4910 4915 4920 4925 4930 4935 21+50 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 33+50 4918.05 4918.25 4917.80 4917.25 4916.72 4916.78 4917.31 4917.86 4918.40 4918.46 4917.97 4917.45 4917.91 4918.17 4918.27 4918.19 4918.08 4917.94 4917.66 4917.53 4917.39 4917.11 4916.98 4916.84 4916.61 4916.55 4916.66 4916.90 4917.04 4917.18 4917.45 4917.59 4917.73 4918.00 4918.14 4918.28 4918.49 4918.52 4918.51 4918.36 4918.23 4918.10 4917.84 4917.71 4917.58 4917.30 12" PVC STA. 30+41.16 12"X8" TEE w/TB 1-12" BFV (E), 1-8" GV (S) T.O.P.=4911.55 STA. 23+21.60 12"X8" TEE w/TB 1-12" BFV (E) & 1-8" GV (N) T.O.P.=4911.33 PROPOSED GROUND EXISTING GROUND TOP OF PIPE PROPOSED GROUND Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 53 NORTH WT2 PLAN & PROFILE 12" WATER LINE - PROSPECT ROAD 8 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 KEYMAP C.O. G 1 2 3 4 5 4 3 2 1 0 G G 1 0 2 0 3 0 4 0 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 G 1 2 3 4 5 4 3 2 1 0 G G 1 2 3 4 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT RD MAIN STREET TRIC WT1 WT2 WT3 12" WATER LINE-PROSPECT RD PROFILE SCALE: MATCH LINE SEE SHEET WT3 STA 33+50 LINE MATCH STA 33+50 MATCH LINE SEE SHEET WT1 STA 21+50 LINE MATCH STA 21+50 SS W EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 8. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 9. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE. 10. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITHIN THE EXISTING 50' GAS LINE EASEMENT WITH MAGELLAN PIPELINE CO. AND COMPLY WITH ALL MAGELLAN PIPELINE CO. CRITERIA. 11. ALL TEES AND CROSSES SHALL USE FOSTER ADAPTERS AND MEGALUGS. 12. CONTRACTOR TO USE 11.25° BEND(S) WITH ALL JOINTS RESTRAINED 5-FT BOTH SIDES OF BEND, IF REQUESTED DURING CONSTRUCTION BY ELCO FIELD INSPECTOR (BASED ON SITE CONDITIONS). 13. CONTRACTOR TO COORDINATE LOCATION OF RELOCATED SERVICE TAPS AND METERS WITH ELCO FIELD STAFF AND CONNECT TO EXISTING HOME'S SERVICE LINE. 14. EXISTING INFORMATION FOR TIMNATH RESERVOIR INLET CANAL, DATED DECEMBER 19, 2019, IMPROVEMENTS BASED ON DESIGN INFORMATION ONLY AND HAVE NOT BEEN SURVEYED. CONTRACTOR TO VERIFY RELEVANT INFORMATION PRIOR TO CONSTRUCTION. 15. THIS PROJECT IS TO BE CONSTRUCTED CONCURRENTLY WITH THE UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2. REFER TO UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2 FOR ADDITIONAL INFORMATION. 16. EXISTING 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE REMOVED BY EAST LARIMER COUNTY WATER DISTRICT DUE TO HAZARDOUS MATERIAL. CONTRACTOR'S DEMOLITION RESPONSIBILITIES FOR THE 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE LIMITED TO EXPOSING THE PIPE. CONTRACTOR SHALL COORDINATE ALL WATER LINE'S DEMOLITION ACTIVITIES WITH EAST LARIMER COUNTY WATER DISTRICT G E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING GAS EXISTING SANITARY SEWER PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED LOT LINE PROPOSED WATER MAIN W EXISTING OVERHEAD UTILITY OHU EXISTING TELEPHONE T EXISTING CABLE CTV City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner UTILITY PLAN REVIEW EAST LARIMER COUNTY WATER DISTRICT M W W CC E C M M CABLE W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / STA.=10+51.62 12"X6" SWIVEL TEE w/TB & 1-6" GV (N) STA.=10+41.62 45° BEND w/TB & 12"X4" REDUCER (E) STA.=16+72.83 12"X8" TEE w/TB 1-8" GV (N) & 2-12" BFV (E,W) 8" SS 8" SS G G G G E E STA.=10+05.00 45° BEND w/TB TEMP FH w/ 8"x6" REDUCER T.O.P. ELEV: 4912.12 N:123615.51 E:218515.17 56' FL-EOA 87.5' ROW ±57' OF SERVICE TO BE EXTENDED WITH 2" HDPE CASING ±57' OF SERVICE TO BE EXTENDED WITH 2" HDPE CASING ±57' OF SERVICE TO BE EXTENDEDWITH 2" HDPE CASING EXISTING GAS LINE EXISTING 15" SANITARY SEWER (BOXELDER) EXISTING 60" GREELEY STEEL WATERLINE 15' UTILITY EASEMENT 8' SIDEWALK 15' UTILITY EASEMENT 8' SIDEWALK 81' DITCH EASEMENT 30' BOXELDER SANITARY EASEMENT 107.5' ROW PROSPECT ROAD MCLAUGHLIN LANE STORM DRAIN (SEE NOTE #14) 24" STEEL CASING PIPE (SEE NOTE #14) 8" WATER LINE EXISTING 60" (SEE ONSITE PLANS) GREELEY STEEL WATERLINE STA.=17+61.34 12"X6" SWIVEL TEE w/TB FH ASSEMBLY & 1-6" GV (N) STA.=16+49.83 12"X12" TEE w/TB & 1-12" BFV (S) 560.25 LF 12" PVC S89°59'09"E 88.51 LF 12" PVC S89°59'09"E 23.01 LF 12" PVC S89°59'09"E FIRE HYDRANT N:123599.91 E:217893.95 FIRE HYDRANT N:123611.74 E:218603.67 12'x6' RCBC (TRIC) SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 TIE TO EXISTING 2" WATERLINE w/ 12"x2" REDUCER N:123516.74 E:218492.14 APPROXIMATE LOCATION OF EXISTING 2" PVC WATERLINE 68.77 LF 12" PVC S00°00'51"W RELOCATED SERVICE FOR 4529 E. PROSCPECT ROAD (NOTE 13) N:123476.79 E:218474.52 30.00 LF 8" PVC S00°00'48"W RELOCATED SERVICE FOR 4533 E. PROSCPECT ROAD (NOTE 13) N:123456.79 E:218474.51 STA.=10+00.00 CONNECT TO EXISTING 4" AC w/ 4"X2" TEE w/TB & 1-2" GV (S) 5.00 LF 4" PVC N89°48'30"E 36.62 LF 4" PVC N45°00'36"E 5.00 LF 4" PVC N89°48'30"E 10.00 LF 12" PVC S89°59'24"E 32.00 LF 2" PVC S00°11'30"E CONNECT TO EXISTING 2" PVC EXISTING 2" PVC 40' CITY OF GREELEY WATER EASEMENT REC. NO. 2006-0079451 JIRON JACKLYN E 4525 E PROSPECT RD EKBLAD LARRY R/LINDA M 4701 E PROSPECT RD WHITE ERIC S. CW SUBTRUST 1100 SE FRONTAGE RD SIGNORELLI JACKLYN C 4529 E PROSPECT RD GRAY VAL/DELORES K 4517 E PROSPECT RD ALVAREZ ALBERTO 4509 E PROSPECT RD POUDRE R-1 SCHOOL DISTRICT 2407 LAPORTE AVE POUDRE SCHOOL DISTRICT 598.21 LF 12" PVC S89°59'09"E 4895 4900 4905 4910 4915 4920 4925 4930 4935 4895 4900 4905 4910 4915 4920 4925 4930 4935 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 21+50 12" PVC 12" PVC 12" PVC STA. 10+00.0 CONNECT TO EXISTING 4" AC T.O.P.=4910.04 STA. 12+50.0 0.3° DEFLECTION T.O.P.=4911.19 STA. 18+50.1 0.0° DEFLECTION T.O.P.=4911.19 STA. 10+51.62 12"X6" SWIVEL TEE w/TB & 1-6" GV (N) T.O.P.=4910.28 STA. 17+61.34 12"X6" SWIVEL TEE w/TB FH ASSEMBLY & 1-6" GV (N) T.O.P.=4911.19 STA. 16+72.83 12"X8" TEE w/TB 1-8" GV (N) & 1-12" BFV (E) T.O.P.=4911.19 STA. 10+05.00 45° BEND w/TB T.O.P.=4910.07 STA. 10+41.62 45° BEND w/TB & 12"X4" REDUCER (E) T.O.P.=4910.23 STA. 16+49.83 <edit>° BEND T.O.P.=4911.19 PROPOSED GROUND EXISTING GROUND 4915.16 4915.05 4915.60 4916.15 4916.70 4917.25 4917.41 4916.94 4916.40 4916.42 4916.95 4917.50 4914.92 4914.78 4914.91 4915.19 4915.33 4915.46 4915.74 4915.88 4916.01 4916.29 4916.43 4916.56 4916.84 4916.98 4917.11 4917.36 4917.42 4917.44 4917.33 4917.21 4917.07 4916.80 4916.66 4916.52 4916.30 4916.23 4916.31 4916.54 4916.67 4916.81 4917.09 4917.22 4917.36 4917.64 TOP OF PIPE PROPOSED GROUND 15" PVC SANITARY STA.=17+42.31 INV.=4898.64 EXISTING 60" GREELEY STEEL WATERLINE STA.=17+06.43 TOP=4904.11 Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 45 NORTH WT1 PLAN & PROFILE 12" WATER LINE - PROSPECT ROAD 6 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 KEYMAP P P C.O. G 1 2 3 4 5 4 3 2 1 0 G G 1 0 2 0 3 0 4 0 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 G 1 2 3 4 5 4 3 2 1 0 G G 1 2 3 4 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT RD MAIN STREET TRIC WT1 WT2 WT3 12" WATER LINE-PROSPECT RD PROFILE SCALE: UTILITY PLAN REVIEW EAST LARIMER COUNTY WATER DISTRICT MATCH LINE SEE SHEET C201 STA 21+50 LINE MATCH STA 21+50 SS W EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 8. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 9. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE. 10. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITHIN THE EXISTING 50' GAS LINE EASEMENT WITH MAGELLAN PIPELINE CO. AND COMPLY WITH ALL MAGELLAN PIPELINE CO. CRITERIA. 11. ALL TEES AND CROSSES SHALL USE FOSTER ADAPTERS AND MEGALUGS. 12. CONTRACTOR TO USE 11.25° BEND(S) WITH ALL JOINTS RESTRAINED 5-FT BOTH SIDES OF BEND, IF REQUESTED DURING CONSTRUCTION BY ELCO FIELD INSPECTOR (BASED ON SITE CONDITIONS). 13. CONTRACTOR TO COORDINATE LOCATION OF RELOCATED SERVICE TAPS AND METERS WITH ELCO FIELD STAFF AND CONNECT TO EXISTING HOME'S SERVICE LINE. 14. SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 G E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING GAS EXISTING SANITARY SEWER PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED LOT LINE PROPOSED WATER MAIN W EXISTING OVERHEAD UTILITY OHU EXISTING TELEPHONE T EXISTING CABLE CTV C M M CABLE W W W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / STA.=10+51.62 12"X6" SWIVEL TEE & 1-6" GV (N) STA.=10+41.62 45° BEND w/TB & 12"X4" REDUCER (E) STA.=16+72.83 12"X8" TEE w/TB 1-8" GV (N) & 2-12" BFV (E,W) 12" SS 12" SS G G G G E E STA.=10+05.00 45° BEND w/TB TEMP FH w/ 8"x6" REDUCER T.O.P. ELEV: 4912.12 N:123615.51 E:218515.17 54' FL-EOA 87.5' ROW ±57' OF SERVICE TO BE EXTENDED WITH 2" HDPE CASING ±57' OF SERVICE TO BE EXTENDED WITH 2" HDPE CASING ±57' OF SERVICE TO BE EXTENDEDWITH 2" HDPE CASING EXISTING GAS LINE EXISTING 15" SANITARY SEWER (BOXELDER) EXISTING 60" GREELEY STEEL WATERLINE 15' UTILITY EASEMENT 8' SIDEWALK 15' UTILITY EASEMENT 8' SIDEWALK 81' DITCH EASEMENT 30' BOXELDER SANITARY EASEMENT 107.5' ROW PROSPECT ROAD MCLAUGHLIN LANE STORM DRAIN (SEE NOTE #14) 24" STEEL CASING PIPE (SEE NOTE #14) 8" WATER LINE EXISTING 60" (SEE NOTE #15) GREELEY STEEL WATERLINE STA.=17+61.34 12"X6" SWIVEL TEE w/ FH ASSEMBLY & 1-6" GV (N) STA.=16+49.83 12"X12" TEE w/TB & 1-12" BFV (S) 560.25 LF 12" PVC S89°59'09"E 88.51 LF 12" PVC S89°59'09"E 23.01 LF 12" PVC S89°59'09"E FIRE HYDRANT N:123599.91 E:217893.95 FIRE HYDRANT N:123611.74 E:218603.67 12'x6' RCBC (TRIC) SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 CONNECT TO EXISTING 2" WATER w/ 12"x2" REDUCER N:123425.82 E:218492.09 APPROXIMATE LOCATION OF EXISTING 2" PVC WATERLINE 159.69 LF 12" PVC S00°01'26"W RELOCATED SERVICE FOR 4529 E. PROSCPECT ROAD (NOTE #13) N:123476.79 E:218474.52 30.00 LF 8" PVC S00°00'48"W RELOCATED SERVICE FOR 4533 E. PROSCPECT ROAD (NOTE #13) N:123456.79 E:218474.51 STA.=10+00.00 CONNECT TO EXISTING 4" AC w/ 4"X2" TEE w/TB & 1-2" GV (S) 5.00 LF 4" PVC N89°48'30"E 36.62 LF 4" PVC N45°00'36"E 5.00 LF 4" PVC N89°48'30"E 10.00 LF 12" PVC S89°59'24"E 32.00 LF 2" PVC S00°11'30"E APPROXIMATE LOCATION EXISTING 2" PVC WATER 40' CITY OF GREELEY WATER EASEMENT REC. NO. 2006-0079451 JIRON JACKLYN E 4525 E PROSPECT RD EKBLAD LARRY R/LINDA M 4701 E PROSPECT RD WHITE ERIC S. CW SUBTRUST 1100 SE FRONTAGE RD SIGNORELLI JACKLYN C 4529 E PROSPECT RD GRAY VAL/DELORES K 4517 E PROSPECT RD ALVAREZ ALBERTO 4509 E PROSPECT RD POUDRE R-1 SCHOOL DISTRICT 2407 LAPORTE AVE POUDRE SCHOOL DISTRICT 598.21 LF 12" PVC S89°59'09"E CONNECT TO EXISTING 2" PVC WATER N:123529.26 E:217852.92 EXISTING WATER METER (TYP.) PVC UTILITY CONDUIT (SEE NOTE #15) EXISTING 12" SANITARY SEWER (BOXELDER) 4895 4900 4905 4910 4915 4920 4925 4930 4935 4895 4900 4905 4910 4915 4920 4925 4930 4935 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 21+50 12" PVC 12" PVC 12" PVC STA. 10+00.0 CONNECT TO EXISTING 4" AC T.O.P.=4910.04 STA. 12+50.0 0.3° DEFLECTION T.O.P.=4911.19 STA. 10+51.62 12"X6" SWIVEL TEE & 1-6" GV (N) T.O.P.=4910.28 STA. 17+61.34 12"X6" SWIVEL TEE w/ FH ASSEMBLY & 1-6" GV (N) T.O.P.=4911.19 STA. 16+72.83 12"X8" TEE w/TB 1-8" GV (N) & 1-12" BFV (E) T.O.P.=4911.19 STA. 10+05.00 45° BEND w/TB T.O.P.=4910.07 STA. 10+41.62 45° BEND w/TB & 12"X4" REDUCER (E) T.O.P.=4910.23 STA. 16+49.83 12"x12" TEE w/ TB & 1-12" BFV (S) T.O.P.=4911.19 PROPOSED GROUND EXISTING GROUND 4915.16 4915.05 4915.60 4916.15 4916.70 4917.25 4917.41 4916.94 4916.40 4916.42 4916.95 4917.50 4914.92 4914.91 4915.19 4915.33 4915.46 4915.74 4915.88 4916.01 4916.29 4916.43 4916.56 4916.84 4916.98 4917.11 4917.36 4917.42 4917.44 4917.33 4917.21 4917.07 4916.80 4916.66 4916.52 4916.30 4916.23 4916.31 4916.54 4916.67 4916.81 4917.09 4917.22 4917.36 4917.64 TOP OF PIPE PROPOSED GROUND 15" PVC SANITARY STA.=17+42.31 INV.=4898.64 EXISTING 60" GREELEY STEEL WATERLINE STA.=17+06.43 TOP=4904.11 Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 53 NORTH WT1 PLAN & PROFILE 12" WATER LINE - PROSPECT ROAD 7 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 KEYMAP C.O. G 1 2 3 4 5 4 3 2 1 0 G G 1 0 2 0 3 0 4 0 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 G 1 2 3 4 5 4 3 2 1 0 G G 1 2 3 4 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT RD MAIN STREET TRIC WT1 WT2 WT3 12" WATER LINE-PROSPECT RD PROFILE SCALE: UTILITY PLAN REVIEW EAST LARIMER COUNTY WATER DISTRICT MATCH LINE SEE SHEET WT2 STA 21+50 LINE MATCH STA 21+50 SS W EXISTING RIGHT OF WAY EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 8. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 9. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE. 10. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITHIN THE EXISTING 50' GAS LINE EASEMENT WITH MAGELLAN PIPELINE CO. AND COMPLY WITH ALL MAGELLAN PIPELINE CO. CRITERIA. 11. ALL TEES AND CROSSES SHALL USE FOSTER ADAPTERS AND MEGALUGS. 12. CONTRACTOR TO USE 11.25° BEND(S) WITH ALL JOINTS RESTRAINED 5-FT BOTH SIDES OF BEND, IF REQUESTED DURING CONSTRUCTION BY ELCO FIELD INSPECTOR (BASED ON SITE CONDITIONS). 13. CONTRACTOR TO COORDINATE LOCATION OF RELOCATED SERVICE TAPS AND METERS WITH ELCO FIELD STAFF AND CONNECT TO EXISTING HOME'S SERVICE LINE. 14. EXISTING INFORMATION FOR TIMNATH RESERVOIR INLET CANAL, DATED DECEMBER 19, 2019, IMPROVEMENTS BASED ON DESIGN INFORMATION ONLY AND HAVE NOT BEEN SURVEYED. CONTRACTOR TO VERIFY RELEVANT INFORMATION PRIOR TO CONSTRUCTION. 15. THIS PROJECT IS TO BE CONSTRUCTED CONCURRENTLY WITH THE UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2. REFER TO UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2 FOR ADDITIONAL INFORMATION. 16. EXISTING 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE REMOVED BY EAST LARIMER COUNTY WATER DISTRICT DUE TO HAZARDOUS MATERIAL. CONTRACTOR'S DEMOLITION RESPONSIBILITIES FOR THE 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE LIMITED TO EXPOSING THE PIPE. CONTRACTOR SHALL COORDINATE ALL WATER LINE'S DEMOLITION ACTIVITIES WITH EAST LARIMER COUNTY WATER DISTRICT G E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING GAS EXISTING SANITARY SEWER PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED LOT LINE PROPOSED WATER MAIN W EXISTING OVERHEAD UTILITY OHU EXISTING TELEPHONE T EXISTING CABLE CTV FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E T T T T T T T T T FO FO FO FO FO FO FO FO G G G G G G G G G G G G G G G G FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO CTV CTV T T T T T T G G G T MH W W W W W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / W W W W W OHE OHE OHE OHE OHE W W W W W W W W G OHU OHU / / / / / / / / / / / / / / / / X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU F .O. T W WV W W W W W W W W W G W W W PROSPECT ROAD / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING 90' ROW EXISTING ±26' EOP-EOP TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING BOXELDER SANITARY EASEMENT (WIDTH VARIES) EXISTING GAS LINE TO REMAIN EXISTING GRAVEL DRIVEWAY APPROACH TO BE REMOVED AND REPLACED EXISTING GRAVEL DRIVEWAY APPROACH TO BE REMOVED AND REPLACED EXISTING GRAVEL DRIVEWAY APPROACH TO BE REMOVED AND REPLACED EXISTING 8" WATER (ELCO) EXISTING FIBER OPTIC VAULT TO BE RELOCATED EXISTING SIGN TO BE REMOVED EXISTING STOP SIGN AHEAD SIGN TO BE REMOVED EXISTING CONCRETE DITCH LACY KEITH W JR 1601 S COUNTY ROAD 5 HEBBELN JAMES E/DEBRA S 1647 ENCHANTMENT DR COOK STANLEY L/CHRISTINE K 1609 S COUNTY ROAD 5 FORT COLLINS, CO 80524 REED SANDRA K 1707 ENCHANTMENT DR FORT COLLINS, CO 80525 LONGMIRE CAROLYN A/ROBERT C 1617 S COUNTY ROAD 5 FORT COLLINS, CO 80524 LOPP JOHN W/PATRICIA A 1701 S COUNTY ROAD 5 FORT COLLINS, CO 80524 LEWIS ALFRED WRAY BEVERLY JANE 1709 S COUNTY ROAD 5 FORT COLLINS, CO 80524 LEBSOCK BRANDON J/KIMBERLY J 1717 S COUNTY ROAD 5 FORT COLLINS, CO 80524 HILL SANDRA K/ANTHONY O 1739 ENCHANTMENT DR FORT COLLINS, CO 80525 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / MAIN STREET MAIN STREET EXISTING GAS EXISTING COMMMUNICATION EXISTING OVERHEAD UTILITY EXISTING CONCRETE IRRIGATION DITCH TO BE REMOVED AS NEEDED EXISTING ELECTRIC PEDESTAL (TO BE RELOCATED IF NEEDED) APPROXIMATE LOCATION OF EXISTING 2" WATER LINE (ELCO) FIBER OPTIC VAULT TO BE RELOCATED EXISTING STOP SIGN TO BE REMVOED EXISTING OVERHEAD UTILITY TO BE REMOVED AND UNDERGROUNDED (SEE NOTE #7) EXISTING OVERHEAD UTILITY TO BE REMOVED AND UNDERGROUNDED (SEE NOTE #7) EXISTING POWER POLE TO BE REMOVED (SEE NOTE #7) EXISTING POWER POLE TO BE REMOVED (SEE NOTE #7) EXISTING POWER POLE TO BE REMOVED (SEE NOTE #7) EXISTING POWER POLE TO BE REMOVED (SEE NOTE #7) HAZARD STRIPS SIGNS TO BE REMOVED EXISTING GRAVEL ACCESS TO BE REMOVED 24" STEEL CASING PIPE (SEE NOTE #8) APPROXIMATE LOCATION EXISTING 2" WATER (ELCO) APPROXIMATE LOCATION EXISTING 8" WATER (ELCO) STOP SIGN TO BE REMOVED EXISTING 15" PVC SANITARY SEWER (BOXELDER) TIMNATH RESERVOIR INLET CANAL (SEE NOTE #8) POUDRE R-1 SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS OHU OHU C / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X W MH F.O. S C.O. S S VAULT CABLE F.O. F.O. F.O. F.O. S SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD S E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO T T T T T T T T T T T T T T T T T T T T T T T T T G G G G G G G G G G G G G G G G G G G G G G G G G G FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / W W W W W W W W W W W W W W W W W W W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X EXISTING ±25' EOP-EOP TO BE REMOVED EXISTING ±25' EOP-EOP TO BE REMOVED EXISTING 10' CONCRETE TRAIL 100' EXISTING ROW 100' EXISTING ROW EXISTING SIGNS TO BE REMOVED SPEED LIMIT SIGN TO BE REMOVED AND REPLACED EXISTING FIBER OPTIC LINES TO REMAIN EXISTING GAS LINE TO REMAIN LINE TO REMAIN EXISTING GAS LINE TO REMAIN EXISTING 8" WATER (ELCO) EXISTING CABLE BOX TO BE REMOVED & RELOCATED ±63 LF 12" ADS CULVERT TO BE REMOVED AND REPLACED EXISTING GRAVEL DRIVEWAY APPROACH TO BE REMOVED AND REPLACED SECTION LINE TRACT B SERRATOGA FALLS 2ND FILING COCHRAN, BRAD M/SANDRA J 1225 S COUNTY ROAD 5 MAIN STREET EXISTING GAS EXISTING ELECTRIC EXISTING COMMUNICATION EXISTING COMMUNICATION EXISTING 8" PVC SANITARY SEWER (BOXELDER) EXISTING CULVERT TO BE REMOVED EXISTING ±8' GRAVEL DRIVEWAY TO BE REMOVED EXISTING 8" WATER (ELCO) POUDRE R-1 SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 SS SS SS SS SS LT LT LT LT LT LT LT LT LT SP SP SP SP SP SP SP SP SP SP SP D / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X F E S F E S W E C S CONTROL IRR VAULT ELEC ELEC BRKR F.O. F.O. CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR F.O. F.O. SD SD SD SD SD SD SD SD SD SD SD E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO T T T T T G G G G G G G G FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W T T T T T F.O. F.O. CONTROL IRR VAULT ELEC ELEC BRKR VAULT ELEC VAULT F.O. VAULT F.O. T WV WV WV W W T W T FO FO FO FO FO G G G G G G FO FO W W E E E CTV CTV T T T T T T T W W W W W W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING 120' ROW 120' EXISTING ROW EXISTING 36.8' EOP-EOP TRACT B SERRATOGA FALLS 2ND FILING DUNN, RICHARD L/CAROL B 5021 KITCHELL WAY COCHRAN, BRAD M/SANDRA J 1225 S COUNTY ROAD 5 EXISTING MAIN STREET GAS EXISTING CULVERT EXISTING 8" WATER (ELCO) PROPOSED SAWCUT SERRATOGA FALLS PARKWAY KITCHELL WAY Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 53 NORTH EX3 DEMOLITION PLAN EXISTING CONDITIONS & 6 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 KEYMAP C.O. G 1 2 3 4 5 4 3 2 1 0 G G 1 0 2 0 3 0 4 0 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 G 1 2 3 4 5 4 3 2 1 0 G G 1 2 3 4 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT RD MAIN STREET TRIC EXISTING ELECTRIC E LEGEND: EXISTING STORM SEWER EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING RIGHT-OF-WAY EXISTING CONTOUR FIELD SURVEY BY: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES. ENGINEER IS NOT RESPONSIBLE FOR UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY OR TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OR TOWN STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 5. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 7. POWERPOLE RELOCATION TO BE COORDINATED WITH UTILITY PROVIDER AT CONSTRUCTION. OVERHEAD UTILITIES TO BE UNDERGROUNDED, UNLESS SPECIFIED OTHERWISE BY UTILITY PROVIDER. 8. EXISTING INFORMATION FOR TIMNATH RESERVOIR INLET CANAL, DATED DECEMBER 19, 2019, IMPROVEMENTS BASED ON DESIGN INFORMATION ONLY AND HAVE NOT BEEN SURVEYED. CONTRACTOR TO VERIFY RELEVANT INFORMATION PRIOR TO CONSTRUCTION. 9. THIS PROJECT IS TO BE CONSTRUCTED CONCURRENTLY WITH THE UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2. REFER TO UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2 FOR ADDITIONAL INFORMATION. 10. EXISTING 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE REMOVED BY EAST LARIMER COUNTY WATER DISTRICT DUE TO HAZARDOUS MATERIAL. CONTRACTOR'S DEMOLITION RESPONSIBILITIES FOR THE 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE LIMITED TO EXPOSING THE PIPE. CONTRACTOR SHALL COORDINATE ALL WATER LINE'S DEMOLITION ACTIVITIES WITH EAST LARIMER COUNTY WATER DISTRICT. EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT VAULT ELEC CONTROL IRR EXISTING ASPHALT & CONCRETE TO BE REMOVED NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 100-019 DATE: JULY 2016 ADDITIONAL SURVEY: NORTHERN ENGINEERING SERVICES, INC. NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 100-019 PROJECT NO. 100-019 DATE: MAY 2019 DATE: JULY 2019 NORTHERN ENGINEERING SERVICES, INC. NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 100-024 PROJECT NO. 694-003 DATE: AUGUST 2019 DATE: JUNE 2014 EXISTING OVERHEAD UTILITY OHU EXISTING FIBER OPTIC FO EXISTING CABLE CTV G EXISTING TELEPHONE T EXISTING GAS EXISTING LOT LINE EASEMENT / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING WATER TO BE REMOVED/LEFT IN PLACE W EX1 EX3 EX2 MATCH LINE - SEE BELOW LEFT MATCH LINE - SEE ABOVE RIGHT MATCH LINE - SEE BELOW LEFT MATCH LINE - SEE ABOVE RIGHT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner OHU OHU OHU OHU OHU OHU S S S C CC WV WV C C T T T FO FO FO FO FO FO / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING ±25' EOP-EOP TO BE REMOVED EXISTING 70' ROW 30' BOXELDER SANITATION DISTRICT UTILITY EASEMENT 81' DITCH EASMENT TIMNATH RESERVOIR INLET CANAL STORM DRAIN (SEE NOTE #8) EXISTING 15" PVC SANITARY SEWER (BOXELDER) SECTION LINE EXISTING SPEED LIMIT SIGN TO BE REMOVED & RELOCATED STORM DRAIN (SEE NOTE #8) SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 EXISTING FENCES TO BE REMOVED EXISTING 4" A.C. WATERLINE TO BE REMOVED (SEE NOTE #10) ±49 LF EXISTING 4" A.C. WATERLINE TO BE REMOVED (SEE NOTE #10) / / / / / / / / / / / / / / / / / EXISTING 4" A.C. WATERLINE TO BE REMOVED (SEE NOTE #10) SPLITTGERBER RICHARD P/MEREDITH JEAN 1600 MEADOWAIRE DR RYAN JEFFREY L/SYBIL A 1601 CARRIAGE RD KNIEVEL JANET A 5001 E PROSPECT RD LACY KEITH W JR 1601 S COUNTY ROAD 5 EXISTING OVERHEAD UTILITY TO BE REMOVED AND UNDERGROUNDED (SEE NOTE #7) EXISTING POWER POLE TO BE REMOVED (SEE NOTE #7) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT ROAD MEADOWAIRE DRIVE CARRIAGE ROAD POUDRE R-1 SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 EXISTING "STOP" SIGN EXISTING "STOP" SIGN SS SS SS SS SS SS W W G G G / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / OHU OHU OHU OHU B M C S GAS C WV B M / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / D / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / T B M H2O WV WV WV W S O TELE VAULT F.O. VAULT VAULT CABLE F.O. C CABLE CABLE CABLE TELE GAS VAULT CABLE F.O. F.O. GAS GAS T GAS H Y D S SD SD SD S G G G FO FO FO FO E T T T T T T T FO FO FO FO FO FO FO FO G G G G FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV T T T T T T T T T T T T T T T T T T T T T T T G G G G G G G G G G G G G G G G G G G G G P H PH MH W W WV / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / W W OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE W W W W W W W W W W W W W W W G OHU OHU / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / OHU OHU OHU WV W W W W W W W W W W W W W W W W W W G W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING ±24' EOP-EOP TO BE REMOVED EXISTING 118' ROW / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / TIMNATH RESERVOIR INLET CANAL EXISTING ±25' EOP-EOP TO BE REMOVED 10' CONCRETE TRAIL IRRIGATION EASEMENT 50' GAS LINE EASEMENT 30' ELCO WATER LINE EASEMENT 55' CACHE LA POUDRE RESERVOIR CO. EASEMENT 30' ELCO WATER LINE EASEMENT TRACT C SERRATOGA FALLS 2ND FILING HEBBELN JAMES E/DEBRA S 1647 ENCHANTMENT DR SANDERS, DENNIS L/DONI D 1623 CAREFREE DR FORT COLLINS, CO 80525 VAN DYNE, DAVID M/AHN HAE K 1622 CAREFREE DR FORT COLLINS, CO 80525 EXISTING CABLE BOX TO BE REMOVED AND RELOCATED HAZARD STRIPS SIGNS TO BE REMOVED EXISTING GRAVEL ACCESS TO BE REMOVED EXISTING MANHOLE EXISTING 8" WATER (ELCO) APPROXIMATE LOCATION EXISTING 2" WATER 24" STEEL CASING PIPE (SEE NOTE #8) EXISTING 15" PVC SANITARY SEWER (BOXELDER) EXISTING STOP SIGNS TO BE REMOVED EXISTING TREES TO BE REMOVED EXISTING FIBER OPTIC 15" STORM PIPE (SEE NOTE #8) EXISTING OVERHEAD UTILITY TO BE REMOVED AND UNDERGROUNDED (SEE NOTE #7) EXISTING 4" A.C. WATERLINE TO BE REMOVED (SEE NOTE #10) EXISTING POWER POLE TO BE REMOVED (SEE NOTE #7) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING POWER POLE TO BE REMOVED (SEE NOTE #7) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING POWER POLE TO BE REMOVED (SEE NOTE #7) MAIN STREET PROSPECT ROAD APPROXIMATE LOCATION EXISTING 8" WATER APPROXIMATE LOCATION EXISTING 2" WATER EXISTING 12" WATERLINE BY OTHERS EXISTING FIRE HYDRANT Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 53 NORTH EX2 DEMOLITION PLAN EXISTING CONDITIONS & 5 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 KEYMAP C.O. G 1 2 3 4 5 4 3 2 1 0 G G 1 0 2 0 3 0 4 0 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 G 1 2 3 4 5 4 3 2 1 0 G G 1 2 3 4 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT RD MAIN STREET TRIC EXISTING ELECTRIC E LEGEND: EXISTING STORM SEWER EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING RIGHT-OF-WAY EXISTING CONTOUR FIELD SURVEY BY: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES. ENGINEER IS NOT RESPONSIBLE FOR UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY OR TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OR TOWN STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 5. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 7. POWERPOLE RELOCATION TO BE COORDINATED WITH UTILITY PROVIDER AT CONSTRUCTION. OVERHEAD UTILITIES TO BE UNDERGROUNDED, UNLESS SPECIFIED OTHERWISE BY UTILITY PROVIDER. 8. EXISTING INFORMATION FOR TIMNATH RESERVOIR INLET CANAL, DATED DECEMBER 19, 2019, IMPROVEMENTS BASED ON DESIGN INFORMATION ONLY AND HAVE NOT BEEN SURVEYED. CONTRACTOR TO VERIFY RELEVANT INFORMATION PRIOR TO CONSTRUCTION. 9. THIS PROJECT IS TO BE CONSTRUCTED CONCURRENTLY WITH THE UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2. REFER TO UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2 FOR ADDITIONAL INFORMATION. 10. EXISTING 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE REMOVED BY EAST LARIMER COUNTY WATER DISTRICT DUE TO HAZARDOUS MATERIAL. CONTRACTOR'S DEMOLITION RESPONSIBILITIES FOR THE 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE LIMITED TO EXPOSING THE PIPE. CONTRACTOR SHALL COORDINATE ALL WATER LINE'S DEMOLITION ACTIVITIES WITH EAST LARIMER COUNTY WATER DISTRICT. EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT VAULT ELEC CONTROL IRR EXISTING ASPHALT & CONCRETE TO BE REMOVED NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 100-019 DATE: JULY 2016 ADDITIONAL SURVEY: NORTHERN ENGINEERING SERVICES, INC. NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 100-019 PROJECT NO. 100-019 DATE: MAY 2019 DATE: JULY 2019 NORTHERN ENGINEERING SERVICES, INC. NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 100-024 PROJECT NO. 694-003 DATE: AUGUST 2019 DATE: JUNE 2014 EXISTING OVERHEAD UTILITY OHU EXISTING FIBER OPTIC FO EXISTING CABLE CTV G EXISTING TELEPHONE T EXISTING GAS EXISTING LOT LINE EASEMENT / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING WATER TO BE REMOVED/LEFT IN PLACE W EX1 EX3 EX2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCH LINE - SEE SHEET EX1 MATCH LINE - SEE BELOW LEFT MATCH LINE - SEE ABOVE RIGHT / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU S H2O H2O H2O H2O H2O H2O WV WV W S C C C M CABLE C M W W CC E C M M CABLE W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / W W W WV W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING ±24' EOP-EOP TO BE REMOVED EXISTING ±24' EOP-EOP EXISTING 60' ROW TIMNATH RESERVOIR INLET CANAL 40' CITY OF GREELEY WATER EASEMENT REC. NO. 2006-0079451 EXISTING 15" PVC SANITARY SEWER (BOXELDER) EXISTING 60" WATERLINE (CITY OF GREELEY) EXISTING 4" A.C. WATERLINE TO BE REMOVED (SEE NOTE #10) EXISTING OVERHEAD UTILITY TO BE REMOVED AND UNDERGROUNDED (SEE NOTE #7) SECTION LINE 24" STEEL CASING PIPE (SEE NOTE #8) EXISTING WATER METER (TYP.) APPROXIMATE LOCATION OF ±100 LF EXISTING 2" PVC WATERLINE TO BE ABANDONED IN PLACE EXISTING SERVICE FOR 4533 E. PROSPECT ROAD TO BE RELOCATED APPROXIMATE LOCATION OF EXISTING 2" PVC WATERLINE TO BE ABANDONED IN PLACE (ELCO) EXISTING SERVICE TO BE RELOCATED EXISTING 4" A.C. WATERLINE TO REMAIN APPROXIMATE LOCATION OF EXISTING 2" PVC WATERLINE EXISTING UTILITY POLE TO BE REMOVED (SEE NOTE #7) EXISTING UTILITY POLE TO BE REMOVED (SEE NOTE #7) JIRON JACKLYN E 4525 E PROSPECT RD WHITE ERIC S. CW SUBTRUST 1100 SE FRONTAGE RD SIGNORELLI JACKLYN C 4529 E PROSPECT RD GRAY VAL/DELORES K 4517 E PROSPECT RD ALVAREZ ALBERTO 4509 E PROSPECT RD TROXELL BARBARA Y 4417 E PROSPECT RD POUDRE R-1 SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT ROAD MCLAUGHLIN LANE APPROXIMATELY 115 LF EXISTING ±12'-16' GRAVEL ROAD TO BE REMOVED SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS CTV CTV CTV CTV CTV CTV CTV W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G G G G G G G G G G CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU S S S MM C W M CABLE CABLE CABLE CABLE CABLE VAULT CABLE C CABLE M CABLE VAULT ELEC ELEC C WV MH MH / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / TIMNATH RESERVOIR INLET CANAL EXISTING 80' ROW 30' BOXELDER SANITATION DISTRICT UTILITY EASEMENT EXISTING ±25' EOP-EOP TO BE REMOVED EXISTING 97.5' ROW 81' DITCH EASMENT EXISTING OVERHEAD UTILITY TO BE REMOVED AND UNDERGROUNDED (SEE NOTE #7) STORM DRAIN (SEE NOTE #8) SECTION LINE EXISTING 15" PVC SANITARY SEWER (BOXELDER) EXISTING ELECTRIC EQUIPMENT TO BE REMOVED & RELOCATED EXISTING OVERHEAD UTILITY TO BE REMOVED AND UNDERGROUNDED (SEE NOTE #7) STORM DRAIN (SEE NOTE #8) 20" STEEL CASING PIPE (SEE NOTE #8) SEE CONSTRUCTION PLANS FOR TIMNATH RESERVOIR INLET CANAL DATED DECEMBER 19, 2019 EXISTING 4" A.C. WATERLINE TO BE REMOVED (SEE NOTE #10) EXISTING UTILITY POLE TO BE REMOVED (SEE NOTE #7) EXISTING UTILITY POLE TO BE REMOVED (SEE NOTE #7) EXISTING POWER POLE TO BE REMOVED (SEE NOTE #7) EXISTING 4" A.C. WATERLINE TO BE REMOVED (SEE NOTE #10) ±49 LF EXISTING 4" A.C. WATERLINE TO BE REMOVED (SEE NOTE #10) / / / / / / / / / / / / / / / / / EXISTING UTILITY POLE TO BE REMOVED (SEE NOTE #7) EKBLAD LARRY R/LINDA M 4701 E PROSPECT RD NICHOLS LIVING TRUST 1601 MEADOWAIRE DR EKBLAD LARRY R/LINDA M 4725 E PROSPECT RD / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / MEADOWAIRE DRIVE PROSPECT ROAD POUDRE R-1 SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 53 NORTH EX1 DEMOLITION PLAN EXISTING CONDITIONS & 4 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 KEYMAP C.O. G 1 2 3 4 5 4 3 2 1 0 G G 1 0 2 0 3 0 4 0 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 G 1 2 3 4 5 4 3 2 1 0 G G 1 2 3 4 5 0 4 0 3 0 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 / / / / / / / / / / / / / / / / / / / / / / / / PROSPECT RD MAIN STREET TRIC EXISTING ELECTRIC E LEGEND: EXISTING STORM SEWER EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING RIGHT-OF-WAY EXISTING CONTOUR FIELD SURVEY BY: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES. ENGINEER IS NOT RESPONSIBLE FOR UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY OR TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OR TOWN STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 5. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 7. POWERPOLE RELOCATION TO BE COORDINATED WITH UTILITY PROVIDER AT CONSTRUCTION. OVERHEAD UTILITIES TO BE UNDERGROUNDED, UNLESS SPECIFIED OTHERWISE BY UTILITY PROVIDER. 8. EXISTING INFORMATION FOR TIMNATH RESERVOIR INLET CANAL, DATED DECEMBER 19, 2019, IMPROVEMENTS BASED ON DESIGN INFORMATION ONLY AND HAVE NOT BEEN SURVEYED. CONTRACTOR TO VERIFY RELEVANT INFORMATION PRIOR TO CONSTRUCTION. 9. THIS PROJECT IS TO BE CONSTRUCTED CONCURRENTLY WITH THE UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2. REFER TO UTILITY PLANS FOR PSD HIGH SCHOOL MIDDLE SCHOOL #2 FOR ADDITIONAL INFORMATION. 10. EXISTING 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE REMOVED BY EAST LARIMER COUNTY WATER DISTRICT DUE TO HAZARDOUS MATERIAL. CONTRACTOR'S DEMOLITION RESPONSIBILITIES FOR THE 4" A.C. WATER LINE IN PROSPECT ROAD SHALL BE LIMITED TO EXPOSING THE PIPE. CONTRACTOR SHALL COORDINATE ALL WATER LINE'S DEMOLITION ACTIVITIES WITH EAST LARIMER COUNTY WATER DISTRICT. EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT VAULT ELEC CONTROL IRR EXISTING ASPHALT & CONCRETE TO BE REMOVED NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 100-019 DATE: JULY 2016 ADDITIONAL SURVEY: NORTHERN ENGINEERING SERVICES, INC. NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 100-019 PROJECT NO. 100-019 DATE: MAY 2019 DATE: JULY 2019 NORTHERN ENGINEERING SERVICES, INC. NORTHERN ENGINEERING SERVICES, INC. PROJECT NO. 100-024 PROJECT NO. 694-003 DATE: AUGUST 2019 DATE: JUNE 2014 EXISTING OVERHEAD UTILITY OHU EXISTING FIBER OPTIC FO EXISTING CABLE CTV G EXISTING TELEPHONE T EXISTING GAS EXISTING LOT LINE EASEMENT / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING WATER TO BE REMOVED/LEFT IN PLACE W EX1 EX3 EX2 MATCH LINE - SEE BELOW LEFT MATCH LINE - SEE ABOVE RIGHT MATCH LINE - SEE SHEET EX2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R D. EAST LARIMER COUNTY WATER DISTRICT GENERAL NOTES FOR CONSTRUCTION Version: 11/22/2019 The following information is condensed from the current "Standard Construction Specifications for Water Mains" (Specification) as adopted by the East Larimer County Water District (‘ELCO’ or ‘District’) and is to be considered as such. In the event of any conflict the full District Specification document shall take precedence over these general notes. 1. Standards and Specifications: Construction shall be per the District Specifications in effect at the start of construction. Material or equipment shall be manufactured per the most recent version of applicable industry standards. 2. Locates: Contractor shall coordinate field locates of all existing utilities prior to commencement of any construction and as required notify all affected utility companies prior to commencing construction. Cost of repairs to any utility damaged during District waterline installation shall be the responsibility of the Contractor. 3. Damage to Property: Contractor shall continuously maintain adequate protection from damage of all public and private property through which the work is done and shall be fully responsible for all costs associated with damage to any and all public and private property. 4. Safety: Contractor shall comply with any and all requirements and regulations as set forth by any local, City, County, State or Federal agency having applicable authority. 5. Landscaping Adjacent to District Waterlines: No landscaping (bushes, shrubs, trees or other plantings) that has a mature height of over 3 feet (3-ft) shall be placed within ten feet (10-ft) of any District waterline or appurtenance (distribution main, service line, fire hydrant, meter, etc.). Bushes or shrubs with a mature height of less than 3-ft shall be placed a minimum 4-ft from any District waterline or appurtenance. The District shall have the right to remove any landscaping that violates this standard, at any time such landscaping is discovered, and shall not be required to replace the removed landscaping. 6. Design Approval and Construction Start: No construction shall begin without prior design acceptance from ELCO. District shall be notified 48 hours in advance of starting construction or testing to allow for scheduling. 7. Permits: Contractor is responsible for obtaining all permits which may be required. For any permitting where the District must apply for a permit the Contractor shall coordinate, cover the cost and schedule the permit acquisition with the District. 8. Changes During Construction: No verbal authorization for field revision shall be given. All requests for such field revision shall be made in writing with the proposed change indicated on a copy of the signed design drawings. Any field revision approved and installed shall also be accurately documented on the As-Built Drawings. 9. Materials of Construction: a. Pipe: All water piping shall be Polyvinyl Chloride (PVC). All PVC piping 6-inch through 12-inch shall be DR 18 (pressure class 235 psi) and manufactured in accordance with AWWA Standard C900, "Polyvinyl Chloride (PVC) Pressure Pipe, 4-inch through 12-inch, For Water Distribution". All PVC piping 14-inch through 24-inch shall be DR 18 (pressure class 235 psi) and manufactured in accordance with AWWA Standard C905, "Polyvinyl Chloride (PVC) Water Transmission Pipe, Nominal Diameters 14-inch through 36". Pipe with a diameter greater than 24 inches shall be specified based on engineered design. b. Tracer Wire: All water piping shall be installed with a twelve (12) gauge solid copper wire, plastic coated, six hundred (600) volt taped to top of pipe and surfaced at each hydrant into a tracer wire box. c. Pipe Joints: Pipe joints shall be made using an integral bell with an elastomeric gasket push-on type joint or using machined couplings of a sleeve type with rubber ring gaskets and machined pipe ends to form a push-on type joint. d. Materials and Installation: All materials installed shall be new and free of manufacturer defects. Any defective or damaged materials noted on the construction site shall be so marked and removed from the site. Under no circumstances shall any PVC piping be installed utilizing mechanical equipment to seat the joints. e. Pipe Fittings: All fittings shall be mechanical joint, ductile iron, manufactured in accordance with AWWA Standard C153. Fittings shall be furnished with a cement-mortar lining of standard thickness class with a 250 psi pressure rating. f. Gate Valves: Gate valves shall conform to AWWA Standard C509 with mechanical joint, 2" open left operating nut and resilient seat. g. Butterfly Valves: Butterfly valves shall be used for all valves 12-inches and larger and conform to AWWA Standard C504 with mechanical joint, 2" open left operating nut, resilient seat and shall be equipped with sand bonnet. h. Fire Hydrants: Hydrants shall conform to AWWA Standard C502, 1" square open-right operating nut. Allowable manufacturers and models are Mueller Super Centurion with epoxy coated shoe or American Flo Control Waterous Pacer WB-67-250X with epoxy coated shoe. All fittings shall be swing assemblies with anchor couplings. i. Pipe, Valve and Fitting Wrap: All fittings, valves, fire hydrant shoes and plugs shall be poly-wrapped with 8-mil thick polyethylene plastic wrap, double layered, and ends securely taped prior to backfill. All fitting bolts shall have zinc caps installed. 10. Bedding: All pipe shall be bedded in 3/4" washed rock uniformly graded and compacted. Trench shall be excavated to a depth below established grade equal to 1/4 of pipe diameter (min. 4"). Bell depressions shall be provided for all joints. In event that unstable trench conditions are encountered at pipeline grade 1-1/2" uniformly graded washed rock shall be used for stabilization. Bedding material shall be placed and compacted under and around sides of the pipe per the pipe manufacturer’s installation recommendations. Note maximum trench width detail. 11. Backfill: Backfill of acceptable material shall be placed in ‘lifts’ of uniform horizontal layers not to exceed 6-inches of compacted depth per lift. Minimum 18" of compacted backfill above pipe must be in place before rolling mechanical equipment type compaction is to be used. Backfill shall be compacted to 95% of optimum density in roadway areas or per road authority’s requirements, and 90% in fields or non-road locations. Backfill compaction testing frequency shall be at least one test per 100-lineal feet of pipeline length and at varying depths and locations in accordance with the requirements of the applicable road authority or beginning 1.5-feet above top of pipe and at 1-foot increments to grade. 12. Joint Restraint: All fittings, tees, plugs and fire hydrants shall be provided with anchor couplings and/or joint restraint in accordance with District Specifications or as required per engineer’s design. Thrust blocks shall be used only as required per field conditions and as approved or directed by the District field inspector. 13. Concrete: All concrete construction, including thrust blocks, shall be completed utilizing Type 5 or equal cement only. 14. Asphalt Replacement: For asphalt pavement that is cut and has been in place less than two years (according to City or County Engineer's record), the cut shall be a minimum of 20 feet in width and will be replaced to the specified depth by a paving machine. 15. Pipe Cover: A minimum cover of 4-1/2 feet of cover over top of pipe shall be maintained throughout the waterline and service line installation, particularly in areas of new grading and drainage swales. Extra bury depth may be required to maintain minimum cover at drainage culvert crossings and/or fire hydrant runs. Maximum allowable cover shall be 6 feet, unless specifically approved by the District. 16. Connection to Existing System: All connections to existing waterlines shall be completed at developer's expense by District personnel or the District's authorized contractor with no exception. 17. Inspection: The District shall have the authority to assign an inspector who shall inspect, check and verify that any and all work, including all materials to be incorporated in the work, excavation, bedding, backfill, testing and all construction methods and practices of the installed facilities is equal to or better than minimum construction requirements as set forth in the District’s Specifications. 18. Testing: All lines shall be pressure tested, chlorinated and flushed by the Contractor in accordance with District Specifications and under the District's supervision. Upon passing chlorination testing, bacteriological testing will be completed by a State certified water quality control laboratory. Copies of all passing test results, including soils compaction in the area of water main construction, shall be provided to the District. 19. Preliminary Acceptance: Preliminary Acceptance shall be issued to the Owner when all project work is complete, tested and operational such that the infrastructure is ready to be accepted by the District. Documentation required prior to issuance of Preliminary Acceptance includes but is not limited to chlorination test report, bacteriological test report, hydrotest report, compaction testing report, verification of project costs, As-built drawings and Record Drawings. Following receipt, review and acceptance by the District of these and other documents as may be required per project specifics, the District will issue Preliminary Acceptance. 20. Project As-Built and Record Drawing Requirements: a. As-Built Drawings are compiled and maintained during construction by the Contractor and identify, in red ink, on-site changes to the original design. As-Built Drawings shall be delivered to the District (electronically in PDF format or otherwise as requested by the District) for acceptance and to the project’s design engineer for creation of Record Drawings. 21. Record Drawings are prepared by the project’s design engineer and shall accurately reflect any change made in the field which varies from the accepted construction plans, as noted in the As-Built Drawings, including at a minimum, field dimensions and elevations, horizontal and vertical locations of underground utilities and appurtenances. The Record Drawings shall be reviewed and accepted by the District prior to Preliminary Acceptance of the project. Record Drawings are to be delivered to the District in electronic format as Adobe (PDF), AutoCAD and ArcView shape files (release version to be confirmed with District at time of submittal). 22. Warranty: The Owner shall warrant all work associated with the waterline installation including, but not limited to the materials, installation workmanship and surface restoration for a period of two years from date of Preliminary Acceptance. During this warranty period the Owner shall repair any defects in the work and maintain the work area. At the close of the two-year warranty period and upon satisfactory correction of any deficiencies noted, the District shall accept the constructed lines and appurtenances as the sole property and responsibility of the District. UTILITY PLAN REVIEW EAST LARIMER COUNTY WATER DISTRICT 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by City of Fort Collins. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 27-01 Northeast corner of C.R.5 and E. Prospect RD., on the end block of a 15" diameter steel pipe. ELEV.= 4918.13 City of Fort Collins Benchmark 47-01 South Side of Prospect Road where it intersects I-25, on the west end of the parapet wall to the bridge (B16 AM) over I-25, On a Dept of Highways brass Cap ELEV.= 4934.13 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (Prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (Prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (Prior City of Fort Collins Datum) = NAVD88 - 3.19' Basis of Bearings The Basis of Bearings is the South line of the Southeast Quarter of Section 15 as bearing North 89° 59' 09" West (assumed bearing). 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: N.A. B. CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. For additional information see separate Stormwater Management Plan / Erosion Control Report for TBD. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Drainage Report for PSD Middle School High School #2 dated March 6, 2020 by Northern Engineering shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 53 CS2 GENERAL & CONSTRUCTION NOTES 2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 7.5' GRADE TIE-IN 2' ACCESS ESMT MATCH EXISTING 16' CENTER MEDIAN 2' ASPHALT SHOULDER 2.2% (TYP.) 2.2% (TYP.) 2.2% (TYP.) 2.2% (TYP.) WIDTH VARIES FL-FL w/ DETACHED SIDEWALK ON NORTH SIDE (PER LCUASS DETAIL 7-2F 1 2 STREET SECTION) PROSPECT ROAD - PROPOSED SECTION (STA. 36+99 - 42+22) 15' UTIL ESMT 8' WALK 10' PKWY 6' BIKE LANE 11' TRAVEL LANE 72' ROADWAY (FL-FL (WIDTH VARIES) 97.5' RIGHT-OF-WAY 57.5' SECTION LINE TO PROPOSED ROW 40' 1 2 ROW 3' BIKE LANE BUFFER MATCH EXISTING 2' ACCESS ESMT 2.2% (TYP.) 2.2% (TYP.) 12' TRAVEL LANE 12' TURN LANE 11' TRAVEL LANE 5' BIKE LANE 12' TURN LANE 76' EOP-EOP w/ DETACHED SIDEWALK (PER SERRATOGA FALLS OFF-SITE PLANS) MAIN STREET/COUNTY ROAD 5 - LONG RANGE ULTIMATE SECTION (RURAL 4 - LANE ARTERIAL) 4:1 4:1 ROADSIDE SWALE (MIN. 2' DEPTH) 2' SHOULDER 80' EOP-EOP 4:1 ROADSIDE SWALE (MIN. 2' DEPTH) 2' SHOULDER 4:1 18" VERTICAL CURB & GUTTER 18" VERTICAL CURB & GUTTER 16' TURN / MEDIAN 140' ROW 54' EOP-EOP 13' TRAVEL LANE 6' BIKE LANE 13' TRAVEL LANE 6' BIKE LANE 2' GRAVEL SHOULDER 2' GRAVEL SHOULDER 4:1 4:1 ROADSIDE SWALE (MIN. 2' DEPTH) 15' UTIL ESMT MATCH EXISTING 54' EOP-EOP w/ DETACHED SIDEWALK (PER SERRATOGA FALLS OFF-SITE PLANS) MAIN STREET/COUNTY ROAD 5 - PROPOSED SECTION (RURAL 2 - LANE ARTERIAL) 16' TURN / MEDIAN 13' TRAVEL LANE 13' TRAVEL LANE 12' TRAVEL LANE 12' TRAVEL LANE 7' BIKE LANE 7' BIKE LANE 8' WALK 140' ROW 15' UTIL ESMT 8' WALK 2.2% (TYP.) 2.2% (TYP.) 2.2% (TYP.) 2.2% (TYP.) MARCH 2020 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: VICINITY MAP NORTH PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 27-01 Northeast corner of C.R.5 and E. Prospect RD., on the end block of a 15" diameter steel pipe. ELEV.= 4918.13 City of Fort Collins Benchmark 47-01 South Side of Prospect Road where it intersects I-25, on the west end of the parapet wall to the bridge (B16 AM) over I-25, On a Dept of Highways brass Cap ELEV.= 4934.13 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (Prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (Prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (Prior City of Fort Collins Datum) = NAVD88 - 3.19' Basis of Bearings The Basis of Bearings is the South line of the Southeast Quarter of Section 15 as bearing North 89° 59' 09" West (assumed bearing). ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R THE RIGHT OF WAYS OF EAST PROSPECT ROAD AND MAIN STREET (COUNTY ROAD 5) LOCATED IN SECTIONS 14, 15, 22, & 23, TOWNSHIP 7 NORTH, RANGE 68 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO OWNER/APPLICANT PROJECT TEAM: SITE ENGINEER Northern Engineering Services, Inc. Andy Reese 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SURVEYOR CONTACT INFORMATION PROJECT TEAM: SHEET INDEX ENGINEER ING N O R T H E RN ROADWAY IMPROVEMENT PLANS FOR UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS----------------- Xcel Energy----------------------------- Pat Kreager (970) 225-7840 ELECTRIC-------- City of Fort Collins Light & Power-- Luke Unruh (970) 416-2724 CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------ East Larimer County Water District-Randy Siddens (970) 493-2044 WASTEWATER--Boxelder Sanitation District-----------Brian Zick (970) 498-0604 STORMWATER- City of Fort Collins Utilities----------- Dan Mogen (970) 305-5989 LANDSCAPE ARCHITECT STORMWATER- Town of Timnath------------------------ Eric Fuhrman (970) 226-0557 GEOTECHNICAL ENGINEER PROJECT LOCATION PROSPECT ROAD & MAIN STREET BHA Design Incorporated Jeff Kroeger, PLA 1603 Oakridge Drive, Suite 100 Fort Collins, Colorado 80525 (970) 223-7577 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 ENGINEER ING N O R T H E RN Ground Engineering Kelsey Van Bemmel, P.E. 41 Inverness Drive East Englewood, Colorado 80112 (303)-289-1989 Ground Engineering Preliminary Subsurface Exploration Program Report Poudre School District New Prospect 6-12 School Fort Collins, Colorado Ground Eng. Project No. 18-0045 Date: November 16, 2018 SUBSURFACE EXPLORATION BY: Poudre School District 315 E Mountain Ave, Fort Collins, Colorado, 80524 (970)-484-0117 TRAFFIC ENGINEER Delich Associates Matt Delich, PE 2272 Glen Haven Drive Loveland, CO 80538-4903 (970) 669-2061 1 CS1 COVER SHEET 2 CS2 GENERAL & CONSTRUCTION NOTES 3 CS3 UTILITY NOTES 4-6 EX1-EX3 EXISTING CONDITIONS & DEMOLITION PLAN 7-9 WT1-WT3 12" WATER LINE - PROSPECT ROAD 10 ST1 STORM CULVERTS A, B, C, & D - PLAN & PROFILE 11 G1 PROSPECT ROAD - GRADING PLAN 12 G2 MAIN STREET - GRADING PLAN 13-17 R1-R5 PROSPECT ROAD - PLAN & PROFILE 18-21 R6-R9 MAIN STREET - PLAN & PROFILE 22-23 R10-R11 PROSPECT ROAD - SIGNAGE & STRIPING PLAN 24 R12 MAIN STREET - SIGNAGE & STRIPING PLAN 25-26 R13-R14 PROSPECT ROAD - ULTIMATE SIGNAGE & STRIPING PLAN 27 R15 MAIN STREET - ULTIMATE SIGNAGE & STRIPING PLAN 28-32 XS1-XS5 PROSPECT ROAD - ROADWAY CROSS SECTIONS 33-36 XS6-XS9 MAIN STREET - ROADWAY CROSS SECTIONS 37-42 XS10-XS15 PROSPECT ROAD - ULTIMATE ROADWAY CROSS SECTIONS 43 TS1 TRAFFIC SIGNAL LAYOUT 44-45 D1-D2 UTILITY DETAILS 46-47 D3-D4 SITE DETAILS 48 D5 DRAINAGE DETAILS 49-50 EC1-EC2 PROSPECT ROAD EROSION CONTROL PLAN 51 EC3 MAIN STREET EROSION CONTROL PLAN 52-53 EC4-EC5 EROSION CONTROL DETAILS Sheet PROSPECT ROAD & MAIN STREET These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 53 CS1 COVER SHEET 1 UTILITY PLAN REVIEW Northern Engineering Services, Inc. EAST LARIMER COUNTY WATER DISTRICT Project No. 100-019 Date: July 2016 Additional Survey: Northern Engineering Services, Inc. Northern Engineering Services, Inc. Project No. 100-019 Project No. 100-019 Date: May 2019 Date: July 2019 Northern Engineering Services, Inc. Northern Engineering Services, Inc. Project No. 100-024 Project No. 694-003 Date: August 2019 Date: June 2014 TYPICAL SECTIONS: CITY OF GREELEY The City's acceptance shall not relieve the design engineer's responsibility for errors, omissions, or design deficiencies for which the City is held harmless.