Loading...
HomeMy WebLinkAboutRENNAT - FDP200006 - DOCUMENT MARKUPS - ROUND 3 - UTILITY PLANSS. TIMBERLINE RD. KECHTER RD. ZEPHYR RD. ALLEY (PRIVATE) 10' TRAVEL LANE 18.58' - 31" DRIVE-OVER CURB & GUTTER 10' TRAVEL LANE 11' TRAVEL LANE 9' UTIL. 76' ROW ESMT. 6' 54' - PKWY 6' PKWY 9' UTIL. ESMT. MINOR COLLECTOR 5' WALK 5' WALK 11' TRAVEL LANE 5' BIKE LANE 3' BUFFER 8' PARKING 5' BIKE LANE 3' BUFFER 8' PARKING 9' UTIL. 53' ROW ESMT. 9' UTIL. ESMT. RESIDENTIAL LOCAL 7' PARKING 30' - 16' TRAVEL 4.5' WALK 4.5' WALK 5.58' PKWY TBC-WALK 5.58' PKWY TBC-WALK 7' PARKING 1' x 1' CONCRETE EDGE 8' UTIL. ESMT. 8' UTIL. ESMT. ALLEY (PRIVATE) - INVERTED CROWN 10' TRAVEL LANE 20' - 10' TRAVEL LANE 8' UTIL. ESMT. 8' UTIL. ESMT. 7' MIN FENCE SETBACK GENERAL NOTES 1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Final Drainage and Erosion Control Report for Rennat Subdivision dated Februaru 12, 2020 by Northern Engineering Services, Inc., shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction 12" W 12" W X SS VAULT ELEC X X X X X IRR WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM UD UD UD LID W S O E T VAULT TELE T LID VAULT TELE W S O H VAULT TELE T VAULT TELE W S O H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC H Y D S S S ELEC E ELEC BRKR X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G X X X X X X X X X X X PROPERTY BOUNDARY (TYP.) MAIL CREEK DITCH UNION PACIFIC RAILROAD DITCH LATERAL FUTURE PEDESTRIAN BRIDGE (BY OTHERS) 200' PUBLIC ACCESS TRAIL EASEMENT 5' TRAIL 5' TRAIL EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK VAULT TELE ELEC E ELEC BRKR X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X FO FO X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X FO FO FO E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E T VAULT TELE W S O H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC H Y D S S S X X X X X X X X X X X X X X X X X SS SS SS SS SS SS SS SS SS SS SS SS SS SS LID VAULT F.O. W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E G G G G S S S S 4940 4945 4950 4955 4960 4965 4970 4975 4980 4940 4945 4950 4955 4960 4965 4970 4975 4980 20+50 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 297.44 LF 8" PVC @ 0.40% SSMH 7 STA 22+19.16 RIM 4964.0± INV. IN 4947.93 (NW) INV. OUT 4947.83 (SE) 323.00 LF 8" PVC @ 0.40% SSMH 8 STA 25+42.16 RIM 4970.2± INV. IN 4949.32 (NW) INV. OUT 4949.22 (SE) 310.71 LF 8" PVC @ 0.40% SSMH 9 STA 28+52.87 RIM 4967.4± INV. IN 4950.67 (NW) INV. OUT 4950.57 (SE) 311.68 LF 8" PVC @ 0.40% SSMH 10 STA 31+64.55 RIM 4965.9± INV. IN 4952.02 (W) INV. OUT 4951.92 (SE) 82.12 LF 8" PVC @ 0.50% SSMH 11 STA ??? RIM 4964.9± INV. OUT 4952.43 (E) 8" PVC WATER STA.=31+81.45 TOP=4961.48 8" PVC WATER STA.=26+29.52 TOP=4967.04 8" PVC SUBDRAIN STA.=26+65.66 INV.=4947.55 18" MIN. E E 4925 4930 4935 4940 4945 4950 4955 4960 4965 4925 4930 4935 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 20+50 SSMH 2-4 STA 15+64.51 RIM 4949.1± INV. IN 4936.57 (W) INV. IN 4936.77 (N) INV. OUT 4936.47 (E) 241.00 LF 8" PVC @ 0.40% SSMH 2-5 STA 18+05.51 RIM 4947.6± INV. IN 4937.63 (W) INV. IN 4937.83 (N) INV. OUT 4937.53 (E) 309.03 LF 8" PVC @ 0.40% SSMH 2 STA 10+00.00 RIM 4954.4± INV. IN 4940.13 (NE) INV. IN 4933.71 (NW) INV. OUT 4933.51 (S) 103.96 LF 8" PVC @ 0.40% SSMH 2-1 STA 11+03.96 RIM 4952.2± INV. IN 4934.23 (W) INV. OUT 4934.13 (SE) 134.04 LF 8" PVC @ 0.40% SSMH 2-2 STA 12+37.99 RIM 4951.0± INV. IN 4934.97 (S) INV. IN 4935.07 (N) INV. OUT 4934.77 (E) 85.51 LF 8" PVC @ 0.40% SSMH 2-3 STA 13+23.51 RIM 4950.2± INV. IN 4935.51 (W) INV. OUT 4935.31 (N) 241.00 LF 8" PVC @ 0.40% EXISTING GROUND 4925 4930 4935 4940 4945 4950 4955 4960 4965 4925 4930 4935 4940 4945 4950 4955 4960 4965 20+50 21+00 22+00 23+00 24+00 24+50 SSMH 2-6 STA 21+14.54 RIM 4947.1± INV. IN 4938.97 (W) INV. IN 4939.17 (N) INV. OUT 4938.87 (E) 209.78 LF 8" PVC @ 0.40% SSMH 2-7 STA 23+24.32 RIM 4946.0± INV. IN 4939.91 (NW) INV. OUT 4939.81 (E) 86.95 LF 8" PVC @ 0.40% SSMH 2-8 STA 24+11.27 RIM 4944.9± INV. OUT 4940.26 (SE) EXISTING GROUND PROPOSED GROUND E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G 4930 4935 4940 4945 4950 4955 4960 4965 4970 4930 4935 4940 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 13+50 PROPOSED GROUND EXISTING GROUND 98.55 LF 8" PVC @ 3.50% SSMH 2-2B STA 12+23.89 RIM 4955.3± INV. IN 4942.68 (NE) INV. OUT 4942.48 (S) 110.32 LF 8" PVC @ 5.00% SSMH 2-2C STA 13+34.21 RIM 4960.5± INV. OUT 4948.20 (SW) SSMH 2-2 STA 10+00.00 RIM 4951.0± INV. IN 4934.97 (S) INV. IN 4935.07 (N) INV. OUT 4934.77 (E) 125.34 LF 8" PVC @ 3.00% SSMH 2-2A STA 11+25.34 RIM 4952.1± INV. IN 4939.03 (N) INV. OUT 4938.83 (S) 18" RCP STORM STA.=12+34.03 INV.=4947.64 E E E E E E E E E E G G G 4935 4940 4945 4950 4955 4960 4965 4970 4975 4935 4940 4945 4950 4955 4960 4965 4970 4975 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50 SSMH 2-4 STA 10+00.00 RIM 4949.1± INV. IN 4936.57 (W) INV. IN 4936.77 (N) INV. OUT 4936.47 (E) 221.20 LF 8" PVC @ 0.40% SSMH 2-4A STA 12+21.20 RIM 4950.6± INV. IN 4937.85 (N) INV. OUT 4937.65 (S) 177.93 LF 8" PVC @ 1.45% SSMH 2-4B STA 13+99.13 RIM 4953.4± INV. IN 4940.63 (NE) INV. OUT 4940.43 (S) 199.56 LF 8" PVC @ 5.40% SSMH 2-4C STA 15+98.69 RIM 4963.4± INV. OUT 4951.40 (SW) PROPOSED GROUND EXISTING GROUND 24" RCP STORM STA.=14+19.15 INV.=4946.67 8" PVC WATER STA.=10+10.01 TOP=4944.39 E E E E E E E E E E E E E G G 4930 4935 4940 4945 4950 4955 4960 4965 4970 4930 4935 4940 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 SSMH 2-5 STA 10+00.00 RIM 4947.6± INV. IN 4937.63 (W) INV. IN 4937.83 (N) INV. OUT 4937.53 (E) 221.20 LF 8" PVC @ 0.40% SSMH 2-5A STA 12+21.20 RIM 4946.2± INV. IN 4938.91 (N) INV. OUT 4938.71 (S) 177.63 LF 8" PVC @ 0.40% SSMH 2-5B STA 13+98.83 RIM 4947.2± INV. IN 4939.82 (N) INV. OUT 4939.62 (S) 177.63 LF 8" PVC @ 0.60% SSMH 2-5C STA 15+76.46 RIM 4953.8± INV. IN 4941.04 (NE) INV. OUT 4940.89 (S) 187.67 LF 8" PVC @ 4.55% SSMH 2-5D STA 17+64.13 RIM 4962.0± INV. OUT 4949.58 (SW) PROPOSED GROUND EXISTING GROUND 8" PVC WATER STA.=10+10.02 TOP=4942.94 24" RCP STORM STA.=15+13.99 INV.=4945.21 E E E E 4930 4935 4940 4945 4950 4955 4960 4965 4970 4930 4935 4940 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+0012+25 87.27 LF 8" PVC @ 0.50% SSMH 2-6B STA 11+80.62 RIM 4948.6± INV. OUT 4940.28 (SW) SSMH 2-6 STA 10+00.00 RIM 4947.1± INV. IN 4938.97 (W) INV. IN 4939.17 (N) INV. OUT 4938.87 (E) 93.35 LF 8" PVC @ 0.50% SSMH 2-6A STA 10+93.35 RIM 4947.5± INV. IN 4939.84 (NE) INV. OUT 4939.64 (S) PROPOSED GROUND 8" PVC WATER EXISTING GROUND STA.=10+10.00 TOP=4942.33 E E E E E E E E E E E E E E E E E E E E E E G G 4935 4940 4945 4950 4955 4960 4965 4970 4975 4935 4940 4945 4950 4955 4960 4965 4970 4975 9+50 10+00 11+0011+25 SSMH 3-3 STA 10+00.00 RIM 4958.2± INV. IN 4946.48 (E) INV. IN 4946.58 (N) INV. OUT 4946.28 (W) 67.50 LF 8" PVC @ 0.50% SSMH 3-3A STA 10+67.50 RIM 4958.7± INV. OUT 4946.92 (S) PROPOSED GROUND EXISTING GROUND E E E E E E E E E E E E E G G G G G G G G G G G G G G E E E E E E E E G G G G G G G G G S S S S S E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E G G S S S S S S S E E E E E E E E E E E G G G G G G G G G G G G G E E E E G G G G S S S S S S S S S S S S S S S w W w W w W w W w W w W w X X X X X X X X X X STMH 8-2 w/ 100-YR ORIFICE PLATE STA 10+08.96 N: 100803.68 E: 202656.49 OUTLET 8-3 STA 10+36.50 N: 100803.69 E: 202684.03 FES 8-1 STA 10+00.00 N: 100803.86 E: 202647.53 8.96 LF 24" RCP @ 0.50% 27.54 LF 24" RCP @ 0.50% EXISTING 36" IRON PIPE EXISTING FENCE EXISTING EDGE OF WATER AT TIME OF SURVEY UNION PACIFIC RAILWAY FUTURE STORM DRAIN (BY OTHERS) 4925 4930 4935 4940 4945 4950 4955 4960 4925 4930 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 11+50 STMH 8-2 STA 10+08.96 RIM 4943.8± INV. IN 4941.04 (E) INV. OUT 4941.04 (W) FES 8-1 STA 10+00.00 INV. 4941.00 (E) OUTLET 8-3 STA 10+36.50 RIM 4944.0± E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G E E E E E E G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E G G G G G G U D UD UD UD UD UD UD VAULT TELE T VAULT TELE W S O H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC H Y D S S S ELEC E ELEC BRKR X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS X X X X X X X X X X X X X X X X X X X X X X X UD UD UD UD UD UD UD UD UD UD UD UNION PACIFIC RAILROAD DITCH LATERAL PLANNED HANSEN FARM BLOCK 11 5' TRAIL 5' TRAIL 5' TRAIL 5' TRAIL 6' UTILITY EASEMENT PROPERTY BOUNDARY (TYP.) PLANNED PEDESTRIAN BRIDGE (SEE HANSEN FARM UTILITY PLANS) EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK NATURAL HABITAT BUFFER ZONE 64.52 67.86 68.29 68.54 68.79 69.04 67.37 68.51 68.26 68.11 67.90 67.25 T ELEC E ELEC BRKR X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X VAULT VAULT VAULT VAULT VAULT VAULT VAULT 6' UTILITY EASEMENT 6' UTILITY EASEMENT 53' ROW 30' FL-FL 20' 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT BLOCK 13 BLOCK 13 BLOCK 7 BLOCK 9 BLOCK 8 BLOCK 9 TRACT F TRACT P TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT DETENTION POND 53' ROW 30' FL-FL 5' TRAIL 5' TRAIL 5' TRAIL 9' UTILITY EASEMENT DANCING CATTAIL DR CROAKING TOAD DR AUTUMN BREEZE CT WATER QUALITY POND 1 WATER QUALITY POND 2 VAULT TELE VAULT F.O. FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E T T T T T T T UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD VAULT VAULT VAULT VAULT 53' ROW 53' ROW H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC S S S X X X X X X X X X X X X X SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS V AULT F.O. FO FO FO FO FO FO FO FO FO FO FO FO FO E T T T T T T T T T T T T T T VAULT TELE W S O H Y D X X X X X X X X X X X X X X X X X SS SS SS LID W W W FO FO FO FO FO FO FO FO FO FO FO FO FO T T T T T T T T T T T G G G G W W W W T VAULT 60' EASEMENT REC. NO. 20100010642 15' EASEMENT REC. NO. 20110070565 9' UTILITY EASEMENT E E E VAULT ELEC S X X X X X X X X X X X X X X X SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W VAULT VAULT VAULT VAULT VAULT VAULT VAULT 76' ROW 54' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT X X BLOCK 1 BLOCK 1 TRACT M TRACT N DU&PAE BLOCK 2 BLOCK 3 VAULT VAULT VAULT VAULT VAULT 6' UTILITY EASEMENT 53' ROW 30' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT BLOCK 16 BLOCK 5 BLOCK 4 TRACT T DUE TRACT J LOT 8 LOT 9 LOT 10 DETENTION POND 1 5' TRAIL TRACT M 8' UTILITY EASEMENT 19.5' EOC-FL 5' TRAIL 5' TRAIL 5' TRAIL WINDY WILLOW DR 18.4% 25.6% 24.3% 27.2% 50.69 50.98 50.79 51.22 53.38 51.42 51.88 53.18 52.91 53.25 54.89 54.42 55.07 56.46 59.34 56.26 58.03 61.16 62.31 62.11 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 9+50 10+00 11+00 12+00 13+00 14+00 15+00 15+75 STREET A CL EXISTING GROUND PROPOSED GRADE 4966.82 4969.02 4970.02 4970.78 4969.80 4968.50 4967.61 4968.23 4968.68 4969.50 4969.77 4969.93 4970.36 4970.65 4970.79 4970.62 4970.39 4970.12 4969.53 4969.13 4968.83 4968.32 4968.19 PROPOSED GRADE EXISTING GROUND PVI STA = 10+00.00 PVI ELEV = 4966.06 100.4' VC HP ELEV = 4971.64 HP STA = 14+96.64 PVI STA = 15+06.68 PVI ELEV = 4972.24 BVCS: 14+56.48 BVCE: 4971.23 EVCS: 15+56.88 EVCE: 4970.73 A.D. = 5.00 K = 20.08 77.2' VC PVI STA = 12+63.65 PVI ELEV = 4967.38 BCVS: 12+25.03 BVCE: 4967.18 ECVS: 13+02.28 EVCE: 4968.15 STA. = 18+97.04 (MISTY MEADOW DRIVE) STA. = 10+00.00 (CROAKING TOAD DRIVE) 53' ROW 30' FL-FL (MISTY MEADOW DRIVE) (WINDY WILLOW DRIVE) STA. = 21+38.04 (MISTY MEADOW DRIVE) STA. = 10+00.00 (FLYING MALLARD DRIVE) MISTY MEADOW DR LOT 4 LOT 15 LOT 14 LOT 1 LOT 2 LOT 10 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 7 LOT 6 LOT 5 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 TRACT S DUA TRACT D DUA&EAE FLYING MALLARD DR SEE SHEET R8 PROPOSED DRIVE OVER CURB AND GUTTER BLOCK 12 BLOCK 12 BLOCK 10 BLOCK 14 BLOCK 15 BLOCK 16 BLOCK 13 PROPOSED 6' CROSSPAN TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G ∆ 30' FL-FL 53' ROW STA. = 23+79.04 (MISTY MEADOW DRIVE) STA. = 24+49.90 (WINDY WILLOW DRIVE) MISTY MEADOW DR LOT 2 LOT 11 LOT 4 LOT 3 LOT 1 LOT 15 LOT 12 LOT 10 LOT 11 LOT 9 LOT 8 LOT 7 LOT 15 LOT 6 TRACT M TRACT D DUA&EAE ZEPHYR RD SEE SHEET R13 BLOCK 4 ZEPHYR RD SEE SHEET R13 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G LOT 15 LOT 17 LOT 16 LOT 3 LOT 1 LOT 2 LOT 12 LOT 6 LOT 10 LOT 9 LOT 8 LOT 7 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1 LOT 14 LOT 2 LOT 10 LOT 9 LOT 2 LOT 1 LOT 3 LOT 1 53' ROW 30' FL-FL TRACT S DUA BLOCK 7 BLOCK 9 BLOCK 8 BLOCK 13 BLOCK 14 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G ∆ LOT 3 LOT 1 LOT 2 LOT 12 LOT 11 LOT 13 LOT 3 LOT 2 53' ROW 30' FL-FL TRACT D DUA&EAE BLOCK 14 BLOCK 15 BLOCK 16 E E E E E E E E E E G G G G G G G G G G G G E E E E E E E E E E E E E E G G G G G G G G E E E E G G G G VAULT VAULT VAULT E E E E E E FLYING MALLARD DR SEE SHEET R8 DANCING CATTAIL DR PROPOSED DRIVE OVER CURB AND GUTTER STA. = 10+00.00 (CROAKING TOAD DRIVE) STA. = 18+97.04 (MISTY MEADOWS DRIVE) STA. = 18+72.78 (CROAKING TOAD DRIVE) STA. = 14+63.78 (DANCING CATTAIL DRIVE) ∆ LOT 10 LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 15 LOT 11 LOT 9 LOT 10 LOT 12 LOT 74 LOT 13 LOT 14 LOT 17 LOT 6 LOT 16 LOT 7 LOT 12 LOT 8 LOT 11 LOT 10 LOT 14 LOT 13 LOT 8 LOT 9 LOT 2 LOT 3 LOT 1 LOT 4 LOT 7 LOT 6 LOT 5 TRACT P TRACT S DUA TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT 53' ROW 30' FL-FL PROPOSED 2' CONCRETE PAN BLOCK 9 BLOCK 13 BLOCK 9 E E E E E E E E X X X X X X LOT 1 LOT 2 PROPERTY BOUNDARY (TYP.) E E E E E E E E E E E G G G G G G G G G G E E E G END OF ROADWAY MARKER DANCING CATTAIL DR SEE SHEET R4 PRAIRIE HILL DRIVE DANCING CATTAIL DR SEE SHEET R4 END PROPOSED ROADWAY FUTURE CROAKING TOAD DR LOT 10 LOT 11 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 0.50% -0.50% 0.50% PVI STA = 26+77.39 PVI ELEV = 4947.00 75.0' VC HP ELEV = 4948.18 HP STA = 20+15.87 PVI STA = 20+15.87 PVI ELEV = 4948.27 BVCS: 19+78.37 BVCE: 4948.08 EVCS: 20+53.37 EVCE: 4948.08 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+25 -2.20% 2.20% -6.00% -0.50% -2.00% -2.00% PVI STA = 10+00.00 PVI ELEV = 4965.71 PVI STA = 10+13.83 PVI ELEV = 4965.40 PVI STA = 16+96.43 PVI ELEV = 4949.11 PVI STA = 16+76.59 PVI ELEV = 4948.80 PVI STA = 16+79.59 PVI ELEV = 4948.73 PVI STA = 16+82.59 PVI ELEV = 4948.80 128.0' VC PVI STA = 11+08.83 PVI ELEV = 4963.50 BVCS: 10+44.83 BVCE: 4964.78 EVCS: 11+72.83 EVCE: 4959.66 A.D. = 4.00 K = 32.00 50.0' VC PVI STA = 16+26.59 PVI ELEV = 4949.80 BVCS: 16+01.59 BVCE: 4949.93 EVCS: 16+51.59 EVCE: 4949.30 A.D. = 1.50 K = 33.33 220.0' VC PVI STA = 13+10.87 PVI ELEV = 4951.38 BCVS: 12+00.87 BVCE: 4957.98 ECVS: 14+20.87 EVCE: 4950.83 A.D. = 5.50 K = 40.00 4965.71 4963.20 4960 4965 4970 4975 4980 4985 4960 4965 4970 4975 4980 4985 9+50 10+00 11+00 12+00 13+00 13+50 4971.64 4971.45 4972.01 4972.61 4973.13 4973.35 4973.25 4972.85 4972.13 4971.11 4970.01 4968.91 4967.81 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 24"x36" STA.=12+15.74 INV.=4967.93 FUTURE GRADE -4.40% -2.20% 2.21% 2.40% PVI STA = 10+00.00 PVI ELEV = 4971.64 PVI STA = 10+13.83 PVI ELEV = 4971.33 PVI STA = 10+16.84 PVI ELEV = 4971.26 PVI STA = 10+19.84 PVI ELEV = 4971.33 PVI STA = 10+44.84 PVI ELEV = 4971.89 PVI STA = 13+03.12 PVI ELEV = 4967.67 136.0' VC HP ELEV = 4973.35 HP STA = 11+29.98 PVI STA = 11+49.98 PVI ELEV = 4974.41 BVCS: 10+81.98 BVCE: 4972.78 EVCS: 12+17.98 EVCE: 4971.42 A.D. = 6.80 K = 20.00 4940 4945 4950 4955 4960 4965 4970 4940 4945 4950 4955 4960 4965 4970 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 EXISTING GROUND PROPOSED GRADE 4964.11 4963.19 4961.99 4960.70 4959.40 4958.10 4956.80 4955.51 4954.20 4952.86 4951.51 4950.19 4949.10 4948.30 4947.80 4947.58 4947.42 4947.28 4947.16 4947.11 4947.24 4947.37 4947.50 4947.64 4947.78 4947.91 4948.05 4948.19 -2.00% -2.00% -0.64% -5.38% 0.55% -5.19% 0.50% 0.50% -0.50% -0.50% PVI STA = 10+26.70 PVI ELEV = 4965.24 PVI STA = 10+36.58 PVI ELEV = 4965.05 PVI STA = 14+86.23 LOT 2 LOT 6 LOT 1 LOT 9 LOT 7 LOT 8 LOT 12 LOT 10 LOT 11 LOT 13 LOT 3 LOT 6 LOT 5 LOT 4 LOT 2 LOT 7 LOT 10 LOT 11 LOT 8 LOT 9 LOT 3 LOT 15 LOT 14 LOT 13 LOT 1 LOT 1 TRACT I TRACT J TRACT D DUA&EAE BLOCK 12 BLOCK 16 E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 19+50 19+00 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 4961.55 4961.89 4963.90 4966.89 4968.89 4969.22 4967.89 4964.92 4961.41 4962.37 4961.73 4961.48 4961.52 4961.65 4962.24 4962.69 4963.24 4964.65 4965.40 4966.15 4967.54 4968.10 4968.54 4969.13 4969.26 4969.29 4969.04 4968.76 4968.38 4967.29 4966.60 4965.79 4964.05 4963.17 4962.29 4960.53 TIE TO SOUTH CURB & GUTTER STA.=14+96.14 EL. = 4968.842 TIE TO NORTH CURB & GUTTER STA.=15+50.27 EL. = 4969.263 PLANNED GRADE EXISTING 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 29+00 28+00 27+00 26+00 25+00 24+00 23+00 22+00 21+00 20+00 19+50 4957.93 4955.47 4954.44 4954.70 4955.23 4958.77 4957.18 4956.52 4955.95 4955.08 4954.77 4954.56 4954.40 4954.46 4954.58 4954.83 4954.95 4955.08 4955.39 PROPOSED GRADE EXISTING GROUND 15" RCP STA.=22+21.17 INV.=4949.20 PROPOSED GRADE EXISTING GROUND 0.50% 0.65% PVI STA = 23+83.12 PVI ELEV = 4955.12 PVI STA = 24+33.12 PVI ELEV = 4955.44 281.7' VC LP ELEV = 4954.40 LP STA = 22+22.31 PVI STA = 21+16.47 PVI ELEV = 4953.78 BCVS: 19+75.64 BVCE: 4958.75 ECVS: 22+57.31 EVCE: 4954.49 A.D. = 4.02 K = 70.00 15" RCP S w W H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC S S X X SS SS SS SS SS E G G G T T T W W W W W W RED WILLOW DR ROSEN DRIVE S w W PROPOSED "STOP" SIGN w/ STREET NAMES 13' PROJECTED FL PROPOSED "25 MPH SPEED LIMIT" SIGN 5 5 5 5 3 VAULT VAULT VAULT S SS SS T W W 5' SIDEWALK 9' UTILITY EASEMENT VAULT TELE VAULT TELE S S S ELEC E ELEC BRKR X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS SS SS SS SS SS VAULT F.O. FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO VAULT VAULT LOT 8 LOT 7 63.72 64.19 63.35 63.43 63.79 63.99 63.90 64.57 64.15 63.96 2.2% 2.0% 1.8% 1.1% 0.2% 0.6% 2.0% 0.9% 1.0% 0.8% 64.39 64.81 64.39 1.5% 2.0% 62.90 63.05 1.9% 1.9% 2.2% 1.2% 2.4% 2.2% 2.2% 0.5% 0.5% 0.5% 77' CROWN TRANSITION 78' CROWN TRANSITION 64.20 62.10 63.34 61.68 61.72 2.3% 2.3% 63.61 63.15 LOT 1 LOT 1 BLOCK 12 BLOCK 13 BLOCK 10 MISTY MEADOW DR CROAKING TOAD DR 90' CROWN TRANSITION 63.54 0.5% VAULT VAULT VAULT AUTUMN BREEZE CT LOT 10 LOT 9 LOT 8 LOT 5 LOT 4 LOT 3 LOT 7 BLOCK 8 R50'' 48.58 47.36 48.34 48.99 HP 48.08 1.0% 1.0% 1.0% 0.5% 2.0% 1.5% 2.0% 4.5' SIDEWALK 46.90 46.56 46.71 0.5% 46.65 46.80 2.0% 47.10 R50' 2.4% 2.5% 2.6% 2.8% DANCING CATTAIL DR 46.47 46.80 46.80 0.5% 0.0% 0.6% 0.5% 2.0% 6' CROSSPAN 46.80 46.80 47.32 47.32 47.40 47.40 46.48 47.02 47.06 46.51 VAULT LOT 3 LOT 2 LOT 7 LOT 1 36' FL-FL R20' R50' R58' 45.5' 47.5' PROJECTED FLOWLINE DANCING CATTAIL DR WINDY WILLOW DR 49.86 50.16 50.45 50.21 49.63 49.40 0.6% 0.7% 0.5% 0.2% 1.1% 0.5% 0.5% 0.8% 0.5% 0.5% LOT 6 49.83 49.40 50.41 50.82 50.62 49.93 50.33 51.03 50.45 53' ROW 30' FL-FL 0.5% 2.5% 2.5% 3.0% 3.0% 2.7% 2.8% 2.8% 2.5% 2.8% 50.94 50.34 57' ROW 0.7% 0.7% 1.0% 0.4% 2.8% E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E G G G VAULT VAULT VAULT 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G VAULT VAULT 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 VERTICAL CURB AND GUTTER LOT 1 12" W 12" W X SS VAULT ELEC X X X X X IRR WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM UD UD UD E E E E E E E E E E E E E E E E E E E E E E E E E E UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT TELE T VAULT TELE W S O H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC VAULT Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EC2 EROSION CONTROL DETAILS 56 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R VEHICLE TRACKING CONTROL PAD SHALL BE LOCATED AT EVERY ACCESS POINT TO THE CONSTRUCTION SITE. A SIGN SHALL BE PLACED NEXT TO THE VEHICLE TRACKING CONTROL PAD TO DESIGNATE THE LOCATION AS THE CONSTRUCTION ENTRANCE/EXIT. VEHICLE TRACKING CONTROL PADS SHALL CONSIST OF HARD, DENSE, DURABLE STONE, ANGULAR IN SHAPE AND RESISTANT TO WEATHERING. ROUNDED STONE (i.e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x4'S, PIPES, DIRT, GRAVEL OR ASPHALT, SHALL BE PLACED IN GUTTER TO FACILITATE Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EC3 EROSION CONTROL DETAILS 57 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 007 EROSION CONTROL FOR CONSTRUCTION ON INDIVIDUAL RESIDENTIAL LOTS PLANTED RIPRAP INSTALLATION RR 008 009 RIPRAP SCHEDULE Storm Line Pipe Diameter (ft) Riprap Type Length of Riprap (ft) Width of Riprap (ft) 2*d50, Depth of Riprap (ft) Storm Line 1 2.00 Type L 12.00 10.00 1.5 Storm Line 2 1.25 Type L 10.00 5.00 1.5 Storm Line 3 1.25 Type L 5.00 5.00 1.5 Storm Line 4 1.00 Type L 5.00 5.00 1.5 Storm Line 5 1.00 Type M 5.00 5.00 2.0 Storm Line 6 2.00 Type L 14.00 12.00 1.5 Storm Line 7 2.00 Type L 8.00 8.00 1.5 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 D1 UTILITY DETAILS 58 100 BEDDING REQUIREMENTS C:\Work\MAPPING\BLOCKS\Logos\SS-New\SFCSD.bmp 101 TYPICAL MANHOLE DETAIL 102 SANITARY SEWER SERVICE CONNECTION C:\Users\smvst\AppData\Local\Temp\A$C0DD72148.dib 104 AIR & VACUUM RELIEF VALVE INSTALLATION 105 TYPICAL UTILITY SERVICE LOCATION 106 STANDARD MANHOLE COVER CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 103 TYPICAL GROUNDWATER BARRIER DETAIL Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 D2 UTILITY DETAILS 59 200 BEDDING REQUIREMENTS 201 TYPICAL CONCRETE THRUST BLOCKS CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 202 TYPICAL FIRE HYDRANT INSTALLATION 203 TPYICAL GATE VALVE INSTALLATION 204 TYPICAL UTILITY SERVICE LOCATION 205 TYPICAL METER PIT INSTALLATION WATER LOWERING ELEVATIONS CROSSING 1 2 3 4 D (FT) T (FT) STORM 1 4946.17 4943.4 4943.4 4946.17 2 2.77 STORM 1 4949.5 4944.9 4944.9 4949.5 1.5 4.6 STORM 1 4950.76 4945.88 4945.88 7950.76 1.5 4.88 STORM 2 4949.84 4946.95 4946.95 4949.84 1.25 2.89 STORM 2 4952.45 4948.48 4948.48 4952.45 1.25 3.97 STORM 2 4953.28 4950.58 4950.58 4953.28 1.25 2.7 STORM 3 4949.59 4947.41 4947.41 4949.59 1.25 2.18 207 WATER LOWERING ELEVATIONS 1 2 3 4 206 SLEEVE LOCATIONS DETAIL Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 D3 DRAINAGE DETAILS 60 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 302 BEDDING REQUIREMENTS 300 TYPE-C INLET 301 SINGLE CURB INLET A A B B A A 304 INLET SCHEDULE INLET SCHEDULE Inlet ID Inlet Size Inlet Type 1-2 Single Combination 1-3 Single Combination 1-4 Single Combination 1-5 Single Combination 1-6 Single Combination 1-7 Single Combination 2-2 Single Area 2-3 Single Combination 3-2 Single Combination 3-3 Single Combination 7-3 Triple Combination 302 STORM MANHOLE DETAIL 400 CONCRETE TRICKLE PAN A A SECTION A-A DIRECTION OF FLOW PROPOSED NATIVE MATERIAL SUBBASE FLOWLINE OF NOTCH FINISH GROUND D L W 6.0" DIRECTION OF FLOW CONCRETE RUN-DOWN NOTE: 1. SEE GRADING PLAN FOR ELEVATIONS AND SLOPES. 2" NOTCH 6" TYP. 6" TYP. 4' CONCRETE PAN & SIDEWALK CHASE 9.5' CONCRETE RUNDOWN 11.5' CONCRETE PAN & SIDEWALK CHASE 4.5' CONCRETE SIDEWALK CHASE PROPOSED CURB & GUTTER & 4' CURB CUT ELEV B ELEV A ELEV C Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 D4 DRAINAGE DETAILS 61 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. SECTION B-B C C A A B B SECTION C-C SECTION A-A SECTION B-B WELL SCREEN FLOW CONTROL PLATE PLAN GENERAL NOTES SECTION D-D D D A A ABBREVIATIONS LEGEND Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 D5 DRAINAGE DETAILS 62 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 501 BIORETENTION DETAIL D5 1. CONTRACTOR SHALL INSTALL BIORETENTION BASINS ACCORDING TO THE APPROVED PLANS AND/OR CONSTRUCTION SPECIFICATIONS. 2. PRE-CONSTRUCTION 2.1. CONTRACTOR SHALL AVOID COMPACTION OF THE BIORETENTION BASIN AREA TO PRESERVE EXISTING INFILTRATION RATES. 2.2. CONTRACTOR SHALL CALL FOR CITY INSPECTIONS AT THE INTERVALS STIPULATED IN THE "DURING CONSTRUCTION INSPECTION CHECKLISTS". 3. DURING CONSTRUCTION: 3.1. CONTRACTOR SHALL PROVIDE CONSTRUCTION OBSERVATION DURING CONSTRUCTION OF THE BIORETENTION BASIN TO ENSURE COMPLIANCE WITH THE APPROVED PLANS AND DESIGN SPECIFICATIONS. 3.2. LOOSE MATERIALS SHALL NOT BE STORED ON THE BIORETENTION AREA. 3.3. THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION, PREVENT SEDIMENT, DEBRIS AND DIRT FROM ANY SOURCE FROM ENTERING THE BIORETENTION SYSTEM. A B G W LOT GRADING NOTES LEGEND 505 TYPICAL LOT GRADING PLAN VIEW ISOMETRIC VIEW GRADING PLAN TYPE "G" (GARDEN LEVEL) LOT PLAN VIEW ISOMETRIC VIEW GRADING PLAN TYPE "B" LOT PLAN VIEW ISOMETRIC VIEW GRADING PLAN 500 TYPE "A" LOT GRADING PLAN 501 TYPE "B" LOT GRADING PLAN 503 TYPE "G" (GARDEN LEVEL) LOT GRADING PLAN 504 TYPE "W" (WALKOUT LEVEL) LOT GRADING PLAN OVERLOT GRADING NOTES: 1. OVERLOT GRADING WILL UTILIZE FINISHED FRONT AND BACK LOT CORNERS AS SHOWN ON THESE GRADING PLANS. INTERIOR FINISHED LOT GRADES SHOWN ON THESE PLANS ARE EXPECTED TO BE ACHIEVED UTILIZING MATERIAL FROM THE BASEMENT EXCAVATIONS; THEREFORE, ONLY THE LOT CORNER ELEVATIONS NEED TO BE ESTABLISHED PRIOR TO ISSUANCE OF BUILDING PERMITS. INTERIOR AND SIDE LOT ELEVATIONS WILL NOT BE ACHIEVED UNTIL THE HOME IS CONSTRUCTED. INDIVIDUAL LOT GRADING CERTIFICATIONS WILL VERIFY ALL PERTINENT ELEVATIONS AFTER THE HOME HAS BEEN CONSTRUCTED. 2. THESE OVERLOT TEMPLATES DO NOT GUARANTEE AN EARTHWORK BALANCE. IMPORT AND/OR EXPORT MAY BE REQUIRED. THE INTENT OF THESE OVERLOT TEMPLATES IS TO PROVIDE GENERAL GUIDANCE FOR OVERLOT GRADING. THESE TEMPLATES MAY NOT APPLY TO ALL LOTS. FIELD CHANGES CAN BE MADE SO LONG AS LOT CORNERS AND DRAINAGE PATTERNS REMAIN PER PLAN. 3. TYPICAL OVERLOT GRADING SHALL BE AT THE DEVELOPER'S DISCRETION. THE TYPE OF FOUNDATION SHOULD BE CONSIDERED WHEN DETERMINING OVERLOT EXTENTS. TEMPLATES SHOWN ARE SUGGESTED GRADING. CONTRACTOR/DEVELOPER MAY ADJUST AS NECESSARY TO BALANCE GRADING. LOT CORNER ELEVATIONS AS SHOWN ON THESE PLANS MAY NOT BE MODIFIED WITHOUT PRIOR APPROVAL OF THE CITY AND ENGINEER. 502 TYPICAL OVERLOT GRADING LOT GRADING RECOMMENDATIONS: PLAN VIEW Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 D7 SITE DETAILS 64 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 700 CURB AND GUTTER/SIDEWALK GENERAL NOTES: 1. 6 IN. X 6 IN. X 10/10 WWF SHALL BE INSTALLED IN RADIUS AND PAN. 2. MINIMUM 6 IN. WIDE PAN FOR RESIDENTIAL STREET. 3. MINIMUM 10 FT. WIDE PAN FOR ARTERIAL AND COLLECTOR STREETS. 701 STREET INTERSECTION GUTTER DETAIL 703 ASPHALT PAVING DETAIL (CROSSPAN) 704 STANDARD DRIVEWAY APPROACH (TYPE I) 705 SUBDRAIN MAIN INSTALLATION DETAILS 706 STANDARD SIDEWALK DETAIL Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 D8 SITE DETAILS 65 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 800 CURB AND GUTTER/SIDEWALK 805 BICYLCE LANE MARKING 802 ACCESS ROAD STENCILING AND SIGN INSTALLATION 804 DEAD END BARRICADE) 806 STANDARD SIDEWALK DETAIL 801 FIRE ACCESS ROAD SIGNS 803 STREET NAME SIGN NOTES: 1. THE SIGN PLATE SHALL BE A MINIMUM OF 12"X18" WITH A THICKNESS OF .080 ALUMINUM CONSTRUCTION. 2. THE SIGN FACE SHALL HAVE A WHITE REFLECTIVE BACKGROUND WITH A RED LEGEND. USE THE STANDARD 3M SCOTCHLITE SIGN FACE NUMBER R7-32 OR EQUIVALENT, WITH RED LETTERING AS SHOWN ABOVE. 3. ARROWS MAY BE NEEDED (LEFT, RIGHT OR DOUBLE), TO DESIGNATE BEGIN AND END OF NO PARKING AREA. FIRE LANE NO PARKING BY ORDER OF THE FIRE MARSHAL STANDARD FIRE LANE SIGN DETAIL UNIVERSAL FIRE LANE SIGN DETAIL 18" 2" 1 1/2" 3/4" 12" 12" FIRE LANE COLOR SCHEDULE BACKGROUND "P" Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 D9 SITE DETAILS 66 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 900 TRUNCATED DOME WARNING 901 SUBDRAIN MAIN INSTALLATION DETAILS 902 ASPHALT PAVING DETAIL (CROSSPAN) RED WHITE BLACK LEGEND, CIRCLE DIAGONAL, BORDER, "ARROW", "FIRE LANE" (FORT COLLINS ONLY) 75' 75' 15' 15' 12"-18" (TYP.) STANDARD DETAIL 1 (WITHOUT STENCIL) 100' 15' 15' 12"-18" (TYP.) STANDARD DETAIL 1 (WITH STENCIL) FIRE LANE NO PARKING STENCIL SHALL BE CENTERED BETWEEN SIGNS ON CURB FACE 15' DETAIL 3 (65' OR LESS) 15' 65' STENCIL SHALL START 15' IN SIGN SHALL BE CENTERED 12"-18" (TYP.) FIRE LANE NO PARKING FIRE LANE NO PARKING MUST BE PRE-APPROVED ACCESS OFFICER MUST PRE-APPROVE THIS APPLICATION 2 APPROVED FIRE LANE SIGNS-BACK TO BACK 35' carport parking NOTE: APPROVED FIRE LANE SIGNS SHALL BE INSTALLED 12" TO 18" FROM BACK OF CURB OR BACK OF SIDEWALK. SIGN MUST FACE THE ONCOMING TRAFFIC. STENCILS SHALL BE IN WHITE LETTERING (3" HT. 1/2" STROKE) ON RED PAINTED CURB. STENCIL SHALL READ "FIRE LANE NO PARKING" 1. 2. 3. 4. R D6 GRADING DETAILS 63 OVERLOT TEMPLATE "A" LOT OVERLOT TEMPLATE "B" LOT OVERLOT TEMPLATE WALKOUT/GARDEN LEVEL 4. GEOTEXTILE LINERS: 4.1. WHERE USED, GEOTEXTILE LINERS (PERMEABLE OR IMPERMEABLE AS PER PLAN) SHALL BE INSTALLED ALONG PERIMETER OF CROSS-SECTION OF THE BIORETENTION CELL. 4.2. WHERE USED, GEOTEXTILE LINERS SHALL BE PLACED IN ACCORDANCE WITH MANUFACTURER'S STANDARDS AND RECOMMENDATIONS. ALL SEAMS AND OPENINGS IN THE LINER SHALL BE SEALED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. 4.3. WHERE USED, IMPERMEABLE GEOMEMBRANE SHEET / LINER SHALL BE 40 MIL THICK, HIGH-DENSITY POLYETHYLENE DESIGNED SPECIFICALLY FOR FLEXIBLE GEOMEMBRANE APPLICATIONS. ADJACENT STRIPS OF IMPERMEABLE LINER SHALL OVERLAP A MINIMUM OF 18", OR PER MANUFACTURER'S SPECIFICATION. 4.4. WHERE USED, CONTRACTOR TO PLACE LINER IN A WAY THAT ENSURES ENOUGH SLACK IN THE LINER TO ALLOW FOR BACKFILL AND SETTLING WITHOUT TEARING THE LINER. 5. AGGREGATES AND BSM: 5.1. ALL AGGREGATES SHALL BE ANGULAR, CRUSHED, WASHED ROCK, CLEAN OF DEBRIS AND WITH NO MORE THAN 1% FINES. 5.2. RESERVOIR AGGREGATE SHALL BE GRADATION ASTM #57 OR #67. 5.3. DIAPHRAGM AGGREGATE SHALL BE "PEA GRAVEL", WITH GRADATION ASTM #8, #89 OR #9. 5.4. THE BIORETENTION SOIL SHALL MEET THE CITY BIORETENTION SAND MEDIA ("BSM") SPECIFICATION FOUND AT:https://www.fcgov.com/utilities/business/builders-and-developers/development-forms-guidelines-regulations/ NOTES: 8" MIN 4" MIN DIAMETER PERFORATED PVC UNDERDRAIN 2" MIN 30" MIN 12" MAX 1 GEOTEXTILE LINER (AS PER PLAN) MAXIMUM ALLOWABLE PONDING DEPTH IS 12" FROM THE TOP OF THE MULCH 4 MAX NON-FLOATABLE MULCH (AS PER PLAN) 3" PONDING DEPTH MUST NOT EXCEED FLOWLINE ELEVATION OF ADJACENT GUTTER FOREBAY IS REQUIRED TO BE PLACED AT ALL INFLOW LOCATIONS; WITH A MINIMUM 3" DROP FROM GUTTER FLOWLINE TO FOREBAY 4" MIN DEPTH OF DIAPHRAGM AGGREGATE 8" MIN DEPTH OF RESERVOIR AGGREGATE 18" MIN DEPTH OF BIORETENTION SAND MEDIA 8" MIN DEPTH THICKENED CURB ADJACENT TO VEHICULAR PAVEMENTS OVERFLOW RISER OPTION (AS PER PLAN) 8" MIN DEPTH THICKENED CURB ADJACENT TO VEHICULAR PAVEMENTS STANDARD CROSS-SECTION 1 2 WALLED CROSS-SECTION PONDING DEPTH MUST NOT EXCEED FLOWLINE ELEVATION OF ADJACENT GUTTER 18" MIN 4" 12" MAX 30" MIN 36" MIN BASIN WIDTH COVER PLATE 8" SIDEWALK CHASE 18" MIN OVERFLOW RISER OPTION (AS PER PLAN) REINFORCED CONCRETE WALLS (AS PER PLAN) 4" MIN DEPTH OF DIAPHRAGM AGGREGATE 8" MIN DEPTH OF RESERVOIR AGGREGATE 18" MIN DEPTH OF BIORETENTION SAND MEDIA MAXIMUM ALLOWABLE PONDING DEPTH IS 12" FROM THE SURFACE OF THE MULCH 4" MIN DIAMETER PERFORATED PVC UNDERDRAIN 6. UNDERDRAIN: 6.1. UNDERDRAIN PIPE TO BE PERFORATED OR SLOTTED. PERFORATIONS OR SLOTS TO BE SMALLER THAN SURROUNDING AGGREGATE TO ENSURE AGGREGATE DOES NOT FALL INTO OR CLOG THE OPENINGS. 6.2. DO NOT WRAP UNDERDRAIN WITH GEOTEXTILE OR SOCK. 6.3. UNDERDRAIN PIPE MUST OUTFALL BY GRAVITY AND MUST TIE INTO A STORMWATER PIPE, INLET OR SYSTEM AND THE LOCATION MUST BE APPROVED BY THE CITY. THE UNDERDRAIN TIE-IN SHALL MEET ALL REQUIRED PIPE SIZE, TYPES, AND COVER REQUIREMENTS THAT MAY APPLY TO PIPING THAT EXTENDS BEYOND THE LIMITS OF THE BIORETENTION CELL AND ENCROACHES INTO PUBLIC RIGHT-OF-WAY OR OTHER PROPERTY. 7. OVERFLOW INLET: 7.1. AN OVERFLOW INLET OR RISER PIPE SHALL BE PROVIDED. 7.2. ALL OVERFLOW RISER PIPE SHALL BE CAPPED WITH A DOME-SHAPED GRATE. 7.3. AN EMERGENCY OVERFLOW ROUTE SHALL BE PROVIDED AND THE LOCATION SHALL BE IDENTIFIED ON THE PLANS. 8. CLEANOUTS: 8.1. PROVIDE CLEANOUTS (AS PER PLAN) TO ALLOW INSPECTION (BY CAMERA) OF THE UNDERDRAIN SYSTEM DURING AND AFTER CONSTRUCTION. 8.2. CLEANOUTS SHALL BE PROVIDED AT EACH BEND GREATER THAN OR EQUAL TO 90° AND EVERY 100' ALONG A STRAIGHT RUN. CLEANOUT SHALL BE INSTALLED PER THE APPROVED PLANS. 8.3. CLEANOUTS SHALL BE A SOLID WALL PVC STRUCTURE FOR ALL VERTICAL SECTIONS WITH FITTINGS TO CONNECT TO DISTRIBUTION AND UNDERDRAIN PIPING MATERIALS, AS REQUIRED. 9. FOREBAY: 9.1. THE FOREBAY SHALL BE EASILY ACCESSIBLE WITH A HARD SURFACED BOTTOM FOR MAINTENANCE PURPOSES. 10. LANDSCAPE MATERIALS 10.1. CONTRACTOR SHALL NOT PLACE WEED BARRIER ANYWHERE WITHIN THE BIORETENTION BASIN. IF MULCH IS PLACED IN THE BIORETENTION BASIN, IT MUST BE NON-FLOATABLE. 10.2. IF MULCH OR COBBLES ARE PLACED IN THE BIORETENTION BASIN, THE MAXIMUM ALLOWABLE WATER DEPTH OF 12" AND REQUIRED BASIN VOLUME MUST BE MEASURED FROM THE TOP SURFACE OF THE MULCH OR COBBLE. 10.3. ROLLED TURF OR SOD IS NOT AN ALLOWABLE LANDSCAPE MATERIAL FOR BIORETENTION BASINS. LOW WATER CONSUMPTION LANDSCAPE PLANTINGS ARE PREFERRED FOR BIORETENTION BASINS. 10.4. LANDSCAPE PLANTINGS SHALL NOT BE PLACED TO IMPEDE DRAINAGE INTO OR OUT OF THE BIORETENTION BASIN. 10.5. TEMPORARY IRRIGATION MAY BE INSTALLED TO ESTABLISH LANDSCAPING OR SEED IN THE BIORETENTION BASIN. 2" MIN 8" MIN 4" 8" NATIVE SOIL ZONE FLAT APPROVED: DETAILS DRAWN BY: CONSTRUCTION DATE REVISED: STORMWATER DETAIL BIORETENTION D-53 CITY OF FORT COLLINS BIORETENTION SAND MEDIA SPECIFICATION PART 1 - GENERAL A.Bioretention Sand Media (BSM) shall be uniformly mixed, uncompacted, free of stones, stumps, roots, or other similar objects larger than two inches. No other materials or substances shall be mixed or dumped within the bioretention area that may be harmful to plant growth or prove a hindrance to the facility's function and maintenance. B.BSM shall be free of plant or seed material of non-native, invasive species, or weeds. C.Fully mixed BSM shall be tested prior to installation and meet the following criteria: 1. P-Index of less than 30 2. pH of 5.5-6.5. Should pH fall outside of the acceptable range, it may be modified with lime (to raise) or iron sulfate plus sulfur (to lower). The lime or iron sulfate must be mixed uniformly into the BSM prior to use in the bioretention facility. 3. Cation Exchange Capacity (CEC) greater than 10 4. Phosphorous (Phosphate, P2O5) not to exceed 69 ppm 5. BSM that fails to meet the minimum requirements shall be replaced at the Contractor's expense. D.BSM shall be delivered fully mixed in a drum mixer. Onsite mixing of piles will not be allowed. Mixing of the BSM to a homogeneous consistency shall be done to the satisfaction of the Owner. PART 2 - SOIL MATERIALS A.Sand 1. BSM shall consist of 60-70% sand by volume meeting ASTM C-33. B. Shredded Paper 1. BSM shall consist of 5-10% shredded paper by volume. 2. Shredded paper shall be loosely packed, approximate bulk density of 50-100 lbs/CY. 3. Shredded paper shall consist of loose leaf paper, not shredded phone books, and shall be thoroughly and mechanically mixed to prevent clumping. C.Topsoil 1. BSM shall consist of 5-10% topsoil by volume. 2. Topsoil shall be classified as sandy loam, loamy sand, or loam per USDA textural triangle with less than 5% clay material. 3. Onsite, native material shall not be used as topsoil. 4. Textural analysis shall be performed on topsoil, preferably at its source, prior to including topsoil in the mix. Topsoil shall be free of subsoil, debris, weeds, foreign matter, and any other material deleterious to plant health. 5. Topsoil shall have a pH range of 5.5 to 7.5 and moisture content between 25-55%. 6. Contractor shall certify that topsoil meets these specifications. D.Leaf Compost 1. BSM shall consist of 10-20% leaf compost by volume. 2. Leaf compost shall consist of Class 1 organic leaf compost consisting of aged leaf mulch resulting from biological degradation and transformation of plant-derived materials under controlled conditions designed to promote aerobic decomposition. 3. The material shall be well composted, free of viable weed seeds and contain material of a generally humus nature capable of sustaining growth of vegetation, with no materials toxic to plant growth. 4. Compost shall be provided by a local US Composting Council Seal of Testing Assurance (STA) member. A copy of the provider's most recent independent STA test report shall be submitted to and approved by the Owner prior to delivery of BSM to the project site. 5. Compost material shall also meet the following criteria: a. 100 percent of the material shall pass through a 1/2 inch screen b. PH of the material shall be between 6.0 and 8.4 c. Moisture content shall be between 35 and 50 percent d. Maturity greater than 80 percent (maturity indicator expressed as percentage of germination/vigor, 80+/80+) e. Maturity indicator expressed as Carbon to Nitrogen ration < 12 f. Maturity indicator expressed as AmmoniaN/NitrateN Ratio <4 g. Minimum organic matter shall be 40 percent dry weight basis h. Soluble salt content shall be no greater than 5500 parts per million or 0-5 mmhos/cm i. Phosphorus content shall be no greater than 325 parts per million j. Heavy metals (trace) shall not exceed 0.5 parts per million k. Chemical contaminants: meet or exceed US EPA Class A standard, 40 CFR 503.13, Tables 1 & 3 levels l. Pathogens: meet or exceed US EPA Class A standard, 40 CFR 503.32(a) levels PART 3 - EXECUTION A.General 1. Refer to project specifications for excavation requirements. B.Placement Method 1. BSM material shall be spread evenly in horizontal layers. 2. Thickness of loose material in each layer shall not exceed 9-inches. 3. Compaction of BSM material is not required. 502 BIORETENTION SAND MEDIA SPECIFICATIONS 12" - 30" DRAIN BASIN 12" - 30" INLINE DRAIN BACKFILL MATERIAL BELOW AND TO SIDES OF STRUCTURE SHALL BE NATIVE SOIL AND BE PLACED UNIFORMLY IN 12" LIFTS AND COMPACTED TO A MIN OF 90% DWG SIZE A SCALE 1:25 SHEET 1 OF 1 DWG NO. 7001-110-111 REV B 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 12 IN - 30 IN DB & ID NON TRAFFIC INSTALLATION TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 9-30-99 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWN BY CJA NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 9-30-99 CJA NON TRAFFIC INSTALLATION BACKFILL MATERIAL BELOW AND TO SIDES OF STRUCTURE SHALL BE NATIVE SOIL AND BE PLACED UNIFORMLY IN 12" LIFTS AND COMPACTED TO A MIN OF 90% 503 TYPICAL BASIN INSTALLATION OPTIONS 505 D5 MODIFIED WATER QUALITY OUTLET STRUCTURE 504 D5 POND OUTLET STRUCTURE (FORT COLLINS DETAIL D-46) ExistWet Pond Pond 1 Rain Garden 1 ELEV A 4940.00 4947.9 4944.5 ELEV B 4943.00 4949.9 4945.5 ELEV C 4944.00 4950.9 4945.5 D wq (FT) N/A N/A N/A LS (FT) 4.00 4.00 4.00 WS (FT) 4.00 4.00 4.00 WO (FT) 1.00 1.00 1.00 HOLE DIA (INCH) N/A N/A N/A # ROWS N/A N/A N/A # COLUMNS N/A N/A N/A 100-YR ORIFICE (INCH) 7.25 N/A N/A SPILLWAY ELEV. 4944.5 4953.0 4946.3 WQ Pond 1 WQ Pond 2 ELEV 1 4941.1 4941.00 ELEV 2 4943.01 4942.2 ELEV 3 4943.61 4943.2 D wq (FT) 1.00 1.00 W1 (FT) 4.00 4.00 L1 (FT) 11.75 3.00 L2 (FT) 3.00 3.00 L3 (FT) 15.75 7.00 HOLE DIA (INCH) 7/8 1/2 # ROWS 4 3 # COLUMNS 1 1 100-YR ORIFICE (INCH) N/A N/A SPILLWAY ELEV. 4944.0 4943.7 R 403 CONCRETE FLARED END SECTION D4 E C B E E C D PLAN 404 FLARED END SECTION TRASH RACK (STORM LINE 2) D4 SECTION C-C SECTION B-B SECTION A-A DETAIL 1 PLAN A A B C C B 401 CONCRETE SIDEWALK CULVERT 402 DETENTION POND DEPTH GAUGE 405 CONCRETE FOREBAY DETAIL FOREBAY 1 (WQ POND 1) FOREBAY 2 (WQ POND 2) W(FT) 10 10 L(FT) 10 12 D(FT) 1.5 1 ELEV A 4941.93 4941.29 ELEV B 4944.76 4943.6 ELEV C 4945.2 4944.22 401 METAL SIDEWALK CULVERT MOUNTING CURB; HOWEVER, CURB MAY BE CUT DOWN TO A HEIGHT OF 2" OR HIGHER FOR EASIER ACCESS AND REPLACED AT PROJECT COMPLETION. OTHER ACCESS DEVICES MAY BE USED AS ACCEPTED BY THE CITY. CURB CUT 50' MIN. 2" MIN. 6" MIN. 6" MIN. ALTHOUGH NOT NORMALLY USED, THE CITY RESERVES THE RIGHT TO REQUIRE VEHICLE TRACKING CONTROL WITH A TEMPORARY CATTLE GUARD AND/OR WHEEL WASH FACILITIES AT SITES WHERE TRACKING ONTO PAVED AREAS BECOMES A SIGNIFICANT PROBLEM AS DETERMINED BY THE CITY INSPECTOR. IF VEHICLE TRACKING CONTROL WITH WHEEL WASH FACILITIES ARE REQUIRED, ALL WHEELS ON EVERY VEHICLE LEAVING THE SITE SHALL BE CLEANED OF MUD USING A PRESSURE-WASHER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A WATER SOURCE AND CONSTRUCTING A WASHWATER SEDIMENT TRAP. 5. 6. IF VEHICLE WHEEL WASH FACILITIES ARE REQUIRED, CONTRACTOR SHALL INSPECT VEHICLE TRACKING CONTROL AND WHEEL WASH FACILITIES DAILY. ACCUMULATED SEDIMENTS SHALL BE REMOVED FROM THE PAD SURFACE. ACCUMULATED SEDIMENT IN THE WASHWATER/SEDIMENT TRAP SHALL BE REMOVED WHEN THE SEDIMENT REACHES AN AVERAGE DEPTH OF 12-INCHES. 4. 5. VTC 000 CONCRETE WASHOUT AREA 002 ROCK SOCK DETAIL 003 VEHICLE TRACKING CONTROL PAD ROCK SOCK SECTION ROCK SOCK PLAN ROCK SOCK JOINTING ROCK SOCK INSTALLATION NOTES 1. SEE PLAN VIEW FOR: - LOCATION (S) OF ROCK SOCKS. 2. CRUSHED ROCK SHALL BE 11 2" (MINUS) IN SIZE WITH A FRACTURED FACE (ALL SIDES) AND SHALL COMPLY WITH GRADATION SHOWN ON THIS SHEET (11 2" MINUS). 3. WIRE MESH SHALL BE FABRICATED OF 10 GAGE POULTRY MESH, OR EQUIVALENT, WITH A MAXIMUM OPENING OF 1 2", RECOMMENDED MINIMUM ROLL WIDTH OF 48". 4. WIRE MESH SHALL BE SECURED USING "HOG RINGS" OR WIRE TIES AT 6" CENTERS ALONG ALL JOINTS AND AT 2" CENTERS ON ENDS OF SOCKS. 5. SOME MUNICIPALITIES MAY ALLOW THE USE OF FILTER FABRIC AS AN ALTERNATIVE TO WIRE MESH FOR THE ROCK ENCLOSURE. GRADATION TABLE SIEVE SIZE MASS PERCENT PASSING SQUARE MESH SIEVES NO. 4 2" 100 1-1/2" 90-100 1" 20-55 3/4" 0-15 3/8" 0-5 MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE, ALL SIDES WIRE ENCLOSED 1 1/2" WASHED ROCK 2' RS 004 SILT FENCE/PERIMETER PROTECTION POSTS PREASSEMBLED SILT FENCE POSTS SHALL OVERLAP AT JOINTS SO THAT NO GAPS EXIST IN SILT FENCE. NOTE: THICKNESS OF GEOTEXTILE POST SHALL BE JOINED AS SHOWN, THEN HAS BEEN EXAGGERATED. ROTATED 180° IN DIRECTION SHOWN AND DRIVEN INTO THE GROUND. SILT FENCE JOINTS DRIVE POSTS VERTICALLY INTO THE GROUND TO A MINIMUM DEPTH OF 18". EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 4" DEEP ALONG THE LINE OF POSTS AND UPSLOPE FROM THE BARRIER. ANCHOR TRENCH SHALL BE EXCAVATED BY HAND, WITH TRENCHER, OR WITH SILT FENCE INSTALLATION MACHINE. NO ROAD GRADERS, BACKHOES, ETC. SHALL BE USED. NOT LESS THAN THE BOTTOM 1' OF THE SILT FENCE FABRIC SHALL BE BURIED IN THE TRENCH. THE TRENCH SHALL BE COMPACTED BY HAND, WITH "JUMPING JACK" OR BY WHEEL ROLLING. COMPACTION SHALL BE SUCH THAT THE SILT FENCE RESISTS BEING PULLED OUT OF ANCHOR TRENCH BY HAND. SILT FENCE INDICATED IN THE PLANS SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES. USE WOOD POSTS OR OTHER MATERIAL AS ACCEPTED BY THE CITY. INSTALLATION NOTES: 1. 2. 3. 4. 5. 6. 7. THE CONTRACTOR SHALL INSPECT SILT FENCE EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT UPSTREAM SEDIMENT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM SEDIMENT REACHES A DEPTH OF 6". SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED BY THE CITY. IF ANY DISTURBED AREA EXISTS AFTER REMOVAL, IT SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. MAINTENANCE NOTES: 1. 2. 3. 4" MIN. 4" MIN. 1 1 2" x 1 1 2" WOODEN FENCE POSTS SF SF SF 001 SWALE WATTLE DIKE NOTES 1. CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE. 2. VEHICLE TRACKING CONTROL IS REQUIRED IF ACCESS TO CONCRETE WASHOUT AREA IS OFF PAVEMENT. 3. SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS. 4. THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR WASTED CONCRETE. 5. THE CONCRETE WASHOUT SHOULD BE EMPTIED WHEN HALF OF TOTAL HOLDING CAPACITY HAS BEEN REACHED. 6. AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AT AN ACCEPTED WASTE SITE. 7. WHEN THE CONCRETE WASHOUT AREA IS REMOVED, THE DISTURBED AREA SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. 8. LOCATION OF CONCRETE WASHOUT AREA IS CONCEPTUAL ONLY. FINAL LOCATION TO BE DETERMINED IN THE FIELD AT CONTRACTOR'S DISCRETION. 3H:1V OR FLATTER SIDE SLOPES 12" MIN 8'x 8' MIN OR AS REQUIRED TO CONTAIN WASTE CONCRETE 12" 2'-0" MIN. COMPACTED EMBANKMENT MATERIAL, TYP. BERM AROUND PERIMETER GROUND SURFACE SIGN TO INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA *IMPERMEABLE LINER MAY BE NEEDED IF GROUND WATER IS ENCOUNTERED. IP 006 CURB INLET PROTECTION A A PLAN VIEW SECTION A-A 2:1 OP WQCV 005 OUTLET PROTECTION ELEC H Y D S S S ELEC E ELEC BRKR X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS SS SS SS SS LID VAULT F.O. W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E T T T T T T T T T T T G G G G G G T T T W W W W W W W 12" W X SS V AULT ELEC X X X X X X IRR WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM UD UD UD VTC VTC VTC VTC RS RS RS RS RS RS RS RS RS RS RS RS SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF WD WD WD WD WD IP IP IP IP IP WD OP OP BLOCK 2 BLOCK 3 BLOCK 2 BLOCK 3 BLOCK 8 BLOCK 6 BLOCK 5 BLOCK 4 BLOCK 12 BLOCK 10 BLOCK 11 BLOCK 7 BLOCK 9 BLOCK 1 BLOCK 13 BLOCK 15 BLOCK 16 BLOCK 14 STORM DRAIN 7 SEE SHEET ST5 STORM DRAIN 4 SEE SHEET ST3 STORM DRAIN 1 SEE SHEET ST1 STORM DRAIN 5 SEE SHEET ST4 STORM DRAIN 2 SEE SHEET ST2 STORM DRAIN 1 SEE SHEET ST1 STORM DRAIN 6 SEE SHEET ST4 STORM DRAIN 2 SEE SHEET ST2 STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 8 SEE SHEET ST5 TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT TRACT I TRACT H TRACT J TRACT F TRACT G TRACT C FUTURE PUBLIC PARK PEDESTRIAN ACCESS EASEMENT TRACT N DU&PAE TRACT E DG&PAE TRACT L DU&PAE TRACT K DUA&EAE TRACT M IP SF SF SF SF SF ECB TRACT T DUE TRACT R DU&AE ECB SF SF ECB ECB RR RR RR RR MU MU MU MU MU 4:1 4:1 4:1 5:1 4:1 5:1 4:1 4:1 5:1 7:1 4:1 4:1 5:1 4:1 139-LF DOUBLE NET EROSION CONTROL BLANKET 2:1 2:1 ECB SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF 20:1 17:1 19:1 17:1 12:1 17:1 13:1 11:1 10:1 58:1 50:1 45:1 13:1 WD X X X X X X X Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EC1 EROSION CONTROL PLAN 55 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH LEGEND: PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET PROPOSED UNDERDRAIN UD WATTLE DIKE INLET PROTECTION IP VEHICLE TRACKING CONTROL PAD VTC SILT FENCE SF SF SF ROCK SOCK RS RIP RAP RR 1. CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. CONTRACTOR TO USE CDOT STRAW MULCH SPECS UNLESS OTHERWISE DIRECTED. 2. SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone ________________________________ 3. CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 4. DRYWELLS AND BIORETENTION MEDIA TO BE INSTALLED AFTER STABILIZATION OF OVERLOT GRADING. 5. ALL DISTURBED SOILS SHALL BE RESEEDED WITH A COVER CROP UPON COMPLETION OF THE INFRASTRUCTURE IMPROVEMENTS. (SEE LANDSCAPE PLANS) THE RECOMMENDED SPECIES AND APPLICATION RATES OF PURE LIVE SEED FOR COVER CROPS ARE AS FOLLOWS: GREAT BASIN WILRYE 3LBS/ACRE GREEN NEEDLEGRASS2LBS/ACRE INDIAN RICEGRASS 1LBS/ACRE SLENDER WHEATGRASS 2LBS/ACRE THICKSPIKE WHEATGRASS 3LBS/ACRE WESTERN WHEATGRASS 4LBS/ACRE TRITICALE 10LBS/ACRE WINTER WHEAT 5LBS/ACRE 6. REFER TO THE FINAL DRAINAGE AND EROSION CONTROL REPORT FOR RENNAT SUBDIVISION DATED: FEBRUARU 12, 2020 FOR ADDITIONAL INFORMATION. 7. SEE LANDSCAPE PLANS FOR PERMANENT STABILIZATION GENERAL NOTES: WD TRAFFIC CONTROL BARRICADE TCB CONCRETE WASH AREA CWA OUTLET PROTECTION OP CONSTRUCTION FENCE CF CF CF LIMITS OF DISTURBANCE LOD SEEDING & MULCH (SEE LANDSCAPE PLANS) MU MATCHLINE-THIS SHEET MATCHLINE-THIS SHEET 1. IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY AS A GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF BEST MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR DIFFERENT BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY DURING CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS REQUIRED BY LOCAL AUTHORITIES. 2. THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH, GRAPHICAL SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY NECESSARILY SHOWN IN THEIR EXACT LOCATION. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY, STATE DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING AUTHORITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR PERMIT HOLDER) TO ENSURE EROSION CONTROL MEASURES ARE PROPERLY MAINTAINED AND FOLLOWED. 4. CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL MEASURES ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL OF SITE STABILIZATION. 5. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR ALL STORM DRAINS, SWALES, PONDS AND RAIN GARDENS UNTIL SITE IS FULLY STABILIZED. 6. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL CONNECTION IS ESTABLISHED WITH DOWNSPOUT. 7. INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN WATTLES FOR BARE SOIL OR GRAVEL SOCKS FOR PAVEMENT, ETC.) 8. CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES, PARTICULARLY THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO MULCHING, EROSION MATS, TEMPORARY IRRIGATION, AND ADDITIONAL WATTLES OR SILT FENCING MAY BE NECESSARY TO ESTABLISH VEGETATIVE COVER AND STABILIZE THE SLOPE. 9. CONTRACTOR IS RESPONSIBLE FOR PREVENTING SEDIMENT FROM UNSTABILIZED LANDSCAPE AREAS FROM MIGRATING ONTO AND ENTERING THE PERMEABLE PAVER SYSTEMS UNTIL UPGRADIENT TRIBUTARY AREAS ARE FULLY STABILIZED. 10. ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE NECESSARY TO ENSURE THAT EACH BUILDING PAD IS STABILIZED THROUGHOUT CONSTRUCTION. AT NO TIME SHALL SEDIMENT BE ALLOWED TO CROSS THE PUBLIC SIDEWALKS. 11. CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION FOR AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR SILT FENCE FOR BARE SOIL, SAND BAGS OR GRAVEL SOCKS FOR PAVEMENT, ETC.) 12. FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100) FEET FROM NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE WAY OR MANMADE DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL SPILL TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. 13. CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE SANITATION UNITS (CONSTRUCTION TOILETS) SHALL BE LOCATED AT LEAST FIFTY (50) FEET FROM ANY STORMWATER INLET, WETLAND, OR DRAINAGE WAY. SAID FACILITIES MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND CONSTRUCTION TOILETS SHALL BE STAKED DOWN. 14. THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH THE CITY'S CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN WINDS ARE OF SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH, IN THE INSPECTOR'S OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND WELFARE. 15. WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER MONTHS) INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS WILL BE TREATED WITH MULCH AND MULCH TACKIFIER OR OTHER MATERIALS APPROVED BY EROSION CONTROL STAFF TO PREVENT EROSION. 16. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING, REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION METHODS. 17. INDIVIDUAL RESIDENTIAL LOT CONSTRUCTION SHALL IMPLEMENT EROSION CONTROL MEASURES SHOWN IN DETAIL 011 ON SHEET EC4 18. CONTRACTOR SHALL KEEP ALL PUBLIC STREETS SURROUNDING THE PROJECT CLEAN FROM ANY CONSTRUCTION TRACK OUT AND WILL CLEAN IT WITHIN 24 HOURS, SHOULD ANY TRACK OUT OCCUR. EROSION CONTROL NOTES: TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING BEST MANAGEMENT PRACTICES (BMPS) STRUCTURAL "INSTALLATION" Construction & Silt Fence Barriers * Flow Barriers (Wattles) * Inlet Filter Bags * Rip Rap Vegetative Temporary Seeding Planting Mulching / Sealant Permanent Seeding Planting Sod Installation Rolled Products : Netting / Blankets / Mats Contour Furrows (Ripping / Disking) Sediment Basin Rock Bags * UTILITIES INSTALLATION FLAT WORK INSTALLATION VERTICAL INSTALLATION LANDSCAPE DEMOBILIZATION Vehicle Tracking Pad * * All Temporary BMPs to be Removed once Construction is Complete Other: Any prior inlets that could use protecting Any prior inlets that could use protecting Anytime the site will sit dormant longer than 30 Days Anytime the site will sit dormant longer than 30 Days Anytime the site will sit dormant longer than 30 Days Under slope stabilization rolled products. Reseeding may be required. E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E G G G G G G G G G G E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G E E E G G UD UD UD UD UD UD UD UD UD UD UD UD G G E E E G G UD UD UD UD UD UD UD VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT E VAULT VAULT VAULT VAULT VAULT TELE T VAULT TELE W S O H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC H Y D S S S ELEC E ELEC BRKR X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS SS SS SS SS LID VAULT F.O. W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E T T T T T T T T T T T G G G G G G T T T W W W W W W W X X X X X X X X X X X X X X X X X X 4 1 2 3 6b 8 10 11a 4 11b 1 2 5 6b 7b 8 3 13 12 12 10 9 9 5 7b 11b 6a 7a 7a 6a 11a CROAKING TOAD DR FLYING MALLARD DR WINDY WILLOW DR MISTY MEADOW DR ZEPHYR RD FALLEN BRANCH DR AUTUMN BREEZE CT DITCH LATERAL UNION-PACIFIC RAILROAD EXISTING POND DETENTION POND 1 RED WILLOW DRIVE DANCING CATTAIL DR 13 WATER QUALITY POND 1 WATER QUALITY POND 2 RAIN GARDEN 1 GRASS LINED SWALE PROVIDES PRE-TREATMENT AND STANDARD WATER QUALITY OS1 OS1 OS2 OS2 X X X X X X X Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 DR1 DRAINAGE EXHIBIT 54 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH MATCHLINE-THIS SHEET MATCHLINE-THIS SHEET LEGEND: PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET DESIGN POINT A FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 1 B2 1.45 ac 1 FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION DRAINAGE SUMMARY TABLE DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) 1 1 4.34 0.54 0.67 14.1 14.1 4.5 19.5 2 2 3.33 0.52 0.65 12.8 12.8 3.5 15.3 3 3 4.32 0.60 0.75 13.9 13.9 5.1 22.1 4 4 23.91 0.37 0.46 11.2 11.2 18.8 81.8 5 5 1.54 0.59 0.74 14.7 14.7 1.7 7.5 6a 6a 0.73 0.60 0.75 11.4 11.4 0.9 4.1 6b 6b 2.26 0.53 0.66 13.5 13.5 2.4 10.3 7a 7a 1.10 0.54 0.68 12.6 12.6 1.2 5.3 7b 7b 3.83 0.54 0.67 14.2 14.2 4.0 17.3 8 8 1.72 0.54 0.67 12.5 12.5 1.9 8.3 9 9 1.57 0.57 0.71 14.9 14.9 1.7 7.3 10 10 0.09 0.63 0.79 6.4 6.4 0.1 0.6 11a 11a 2.23 0.60 0.75 13.3 13.3 2.6 11.6 11b 11b 0.95 0.37 0.46 10.4 10.4 0.8 3.4 12 12 3.05 0.52 0.65 15.5 15.5 2.9 12.8 13 13 2.51 0.59 0.74 13.0 13.0 2.9 12.9 OS1 OS1 0.34 0.71 0.88 13.0 13.0 0.5 2.1 POND SUMMARY TABLE Pond ID 100-Yr. Detention Vol. (Ac-Ft) Total Req'd Vol. (Ac-Ft) 100-Yr. Detention WSEL (Ft) Peak Release (cfs) Pond 1 0.81 0.81 4952.80 10.10 Existing Wet Pond 10.26 10.26 4943.60 4.20 LOT 2 LOT 10 LOT 3 LOT 9 LOT 8 LOT 6 LOT 5 LOT 1 LOT 2 LOT 1 LOT 4 LOT 7 TRACT T DUE BLOCK 6 BLOCK 2 BLOCK 4 BLOCK 1 TRACT M LOT 2 LOT 3 BLOCK 6 TRACT L DU&PAE TRACT E DG&PAE VERTICAL CURB AND GUTTER SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 21+00 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 -2.24% -2.20% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 21+50 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 -2.24% -2.21% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 22+00 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 -2.29% -2.23% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 22+50 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 -2.20% -2.17% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 23+00 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 -2.11% -2.23% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 23+50 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 -1.87% -1.81% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 24+00 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 -0.86% -0.10% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 24+50 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 25+00 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 4953.0 4952.99 4950.9 4950.87 4949.4 4949.43 4948.7 4948.68 4948.7 4948.71 4949.4 4949.39 4951.6 4951.64 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE 4955.6 4955.60 4954.9 4954.91 B M KEYMAP Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 XS2 CROSS SECTIONS ZEPHYR RD 53 XS1 XS2 20+00 20+50 21+00 9' UTILITY EASEMENT 9' UTILITY EASEMENT 5' SIDEWALK 5' SIDEWALK VERTICAL CURB AND GUTTER VERTICAL CURB AND GUTTER LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 LOT 22 LOT 12 LOT 13 LOT 10 LOT 11 LOT 9 LOT 8 LOT 7 TRACT C FUTURE PUBLIC PARK PEDESTRIAN ACCESS EASEMENT BLOCK 1 ZEPHYR RD BLOCK 3 TRACT M BURLY TREE DR SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 15+00 4962 4964 4968 4972 4976 4962 4964 4968 4972 4976 -40 -20 0 20 40 -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 15+50 4962 4964 4968 4972 4976 4962 4964 4968 4972 4976 -40 -20 0 20 40 -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 16+00 4962 4964 4968 4972 4976 4962 4964 4968 4972 4976 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 16+50 4962 4964 4968 4972 4976 4962 4964 4968 4972 4976 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 17+00 4958 4960 4964 4968 4972 4958 4960 4964 4968 4972 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 17+50 4958 4960 4964 4968 4972 4958 4960 4964 4968 4972 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 18+00 4958 4960 4964 4968 4972 4958 4960 4964 4968 4972 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 18+50 4954 4956 4960 4964 4968 4954 4956 4960 4964 4968 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 19+00 4954 4956 4960 4964 4968 4954 4956 4960 4964 4968 -40 -20 0 20 40 -2.04% -2.04% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 19+50 4950 4952 4956 4960 4964 4950 4952 4956 4960 4964 -40 -20 0 20 40 -2.10% -2.09% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 20+00 4950 4952 4956 4960 4964 4950 4952 4956 4960 4964 -40 -20 0 20 40 -2.17% -2.15% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 20+50 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 -2.22% -2.18% 4968.9 4968.89 4969.3 4969.26 4969.5 4969.49 4969.8 4969.81 4968.2 4968.23 4966.5 4966.54 4964.5 4964.48 4962.6 4962.59 4961.1 4961.13 4959.6 4959.62 4957.7 4957.68 4955.5 4955.47 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE B M KEYMAP Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 XS1 CROSS SECTIONS ZEPHYR RD 52 XS1 XS2 0.4% 0.5% 2.3% 2.3% 0.5% 0.4% 0.5% 0.5% ALLEY 2 CROAKING TOAD DR LOT 2 LOT 1 LOT 1 LOT 17 LOT 16 46.99 47.06 47.27 47.21 47.37 47.29 47.21 47.44 47.29 47.06 47.27 46.98 47.12 47.48 47.48 0.3% 1.3% 0.2% 0.6% 0.5% 0.5% 0.5% 1.1% 0.5% 0.5% 0.5% 1.4% 1.8% 1.2% 47.48 47.75 47.55 1.0% 1.4% 0.9% 47.48 47.75 47.55 47.70 48.12 47.70 47.71 48.09 47.73 47.77 48.16 47.79 47.95 48.37 47.95 0.6% 0.7% 0.6% 0.6% 1.1% 1.8% 2.0% 2.2% 2.2% 0.8% 1.3% 0.6% 0.1% 0.1% 0.1% 0.5% 0.8% 0.5% 0.6% 1.1% 1.8% 2.0% 2.3% 2.3% 0.5% 1.2% 1.2% 1.2% 1.4% 0.7% 47.48 47.55 47.63 47.14 47.14 0.5% 0.5% 0.5% 0.5% 2.2% 2.2% 2.2% 2.2% 2.2% 2.2% LOT 11 BLOCK 7 BLOCK 6 BLOCK 9 BLOCK 13 53' ROW 30' FL-FL 4.5' SIDEWALK 0.5% 0.5% 0.5% 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 53' ROW 30' FL-FL DANCING CATTAIL DR 75' CROWN TRANSITION 75' CROWN TRANSITION 6' CROSSPAN 6' CROSSPAN 47.70 47.40 LOT 10 47.30 47.24 47.01 46.98 47.54 47.63 47.73 47.84 47.69 46.98 47.02 47.69 47.61 47.77 47.86 47.70 47.39 47.35 47.94 47.96 47.91 47.29 47.28 48.00 48.05 47.29 47.28 47.94 47.91 47.97 47.41 47.45 48.00 48.05 1.2% 1.6% 1.6% 1.7% 2.2% 2.2% 2.2% 2.2% 47.29 47.24 VAULT VAULT LOT 1 LOT 2 LOT 12 LOT 13 48.49 48.83 48.59 48.77 48.87 49.00 48.87 48.49 49.11 49.30 48.92 0.5% 0.5% 2.3% 2.3% 2.3% 2.3% 0.5% 4.8% 0.7% 48.91 49.24 49.05 1.0% 1.4% 0.7% 49.39 49.93 49.40 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 48.68 0.5% 49.28 49.79 49.31 48.68 0.6% 0.7% 0.5% 49.10 LOT 7 LOT 9 LOT 8 LOT 6 BLOCK 6 BLOCK 14 BLOCK 15 53' ROW 30' FL-FL DANCING CATTAIL DR FLYING MALLARD DR 75' CROWN TRANSITION 2.2% 0.4% 1.5% 0.1% 2.2% 1.9% 2.3% 2.2% 0.5% 0.5% 0.5% 1.1% 1.3% 2.0% 2.3% 2.3% 57' ROW 36' FL-FL 30' FL-FL 48.85 49.46 49.50 48.89 48.96 48.99 49.54 49.63 49.55 49.49 49.40 49.61 49.70 0.5% 48.58 48.50 49.13 49.23 49.33 49.22 49.42 49.52 49.61 49.06 48.97 0.5% 1.3% 1.3% 48.83 48.85 49.33 49.36 49.42 49.45 48.79 48.74 TELE VAULT ELEC VAULT ELEC VAULT ELEC X E E G G G T T T T 55.39 55.00 55.32 0.6% ZEPHYR RD ROSEN DRIVE RED WILLOW DRIVE (55.79) BLOCK 1 54.15 54.85 54.16 (55.09) 55.02 0.7% 0.5% 1.4% 2.1% 2.1% 54.97 55.10 55.26 54.38 54.37 54.63 54.70 55.11 54.90 1.7% 1.8% 0.9% 1.2% 0.8% 0.1% 0.6% 0.5% 1.0% 1.8% 2.2% 87' CROWN TRANSITION 55.71 56.20 55.63 56.07 55.95 55.30 55.39 55.60 55.58 1.7% 0.6% VAULT LOT 6 LOT 5 LOT 74 LOT 13 LOT 14 0.5% PROPOSED CURB CUT & SIDEWALK CULVERT (SEE DTL 401 SHEET D4) 46.25 45.62 45.11 45.62 46.24 75' CROWN TRANSITION 46.67 46.28 46.04 46.00 2.1% 2.2% 2.2% 46.06 46.45 46.13 1.5% 2.2% CROAKING TOAD DR 45.88 45.54 2.3% 2.8% 46.05 46.01 46.66 46.25 75' CROWN TRANSITION 2.3% 0.5% 2.2% 2.2% 46.45 46.02 46.13 1.5% 2.2% 0.5% 0.8% 0.8% 1.6% 0.5% 0.5% 2.0% 2.0% 1.0% 1.7% 1.0% 1.7% 0.5% 0.5% 0.5% 2.0% 1.6% 2.0% 53' ROW 30' FL-FL CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP INT3 INTERSECTION DETAILS 51 A G H K EYEBROW DETAIL K C D E F L I J B I INTERSECTION DETAIL J L NORTH INTERSECTION DETAIL INTERSECTION DETAIL M INTERSECTION DETAIL M 46.60 46.63 47.10 47.19 47.11 46.47 46.98 47.00 46.50 47.07 47.09 47.05 46.89 47.22 46.63 46.80 2.2% 2.2% 2.2% 2.2% 2.2% 2.2% 0.5% 0.5% 0.5% 0.5% VAULT LOT 12 LOT 10 LOT 9 LOT 14 LOT 1 LOT 2 DANCING CATTAIL DR R50'' 45.78 45.38 46.29 0.9% 0.5% 1.0% 1.0% 44.20 45.23 45.86 2.0% 0.0% 0.5% BLOCK 7 BLOCK 8 4.5' SIDEWALK 4.5' SIDEWALK 2.2% 2.2% 46.28 45.86 53' ROW 30' ROW R50' 3.0% 2.7% 2.3% 2.0% 2.0% PROPOSED 4' CURB CUT & SIDEWALK CULVERT (SEE DTL 401 SHEET D4) PROPOSED FOREBAY 2 (SEE DETAIL SHEET D4) WQ POND 2 44.74 44.69 45.18 45.22 45.31 45.27 44.89 45.39 45.36 44.84 45.45 45.48 VAULT LOT 10 61.88 61.70 63.19 62.23 62.56 63.24 61.71 63.63 62.09 1.9% 2.5% 2.0% 2.4% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 64.92 62.87 3.2% 2.4% 2.5% 61.31 61.46 60.98 3.4% 2.7% 30' FL-FL 53' ROW MISTY MEADOW DR DANCING CATTAIL DR 58.98 58.42 58.48 2.4% 2.2% 59.87 59.48 59.28 2.6% 1.6% 60.76 60.45 60.23 2.3% 0.8% 0.1% 1.9% 62.14 1.6% 1.6% 3.5% 4.3% 4.4% 4.4% 3.6% 3.8% 2.8% 0.5% 2.1% 3.7% 62.49 2.0% 1.1% 2.0% 2.0% 36' FL-FL 57' ROW LOT 11 LOT 1 LOT 2 TRACT C FUTURE PUBLIC PARK PEDESTRIAN ACCESS EASEMENT BLOCK 5 BLOCK 16 121' CROWN TRANSITION 4.5' SIDEWALK 4.5' SIDEWALK 62.11 62.38 62.47 62.20 62.47 62.56 61.75 61.72 62.15 62.12 62.08 61.85 61.83 62.18 62.24 62.31 62.22 62.11 62.02 63.26 63.04 62.30 62.40 63.13 63.35 63.89 63.80 62.73 62.64 VAULT VAULT VAULT LOT 2 LOT 3 LOT 1 55.77 55.08 55.43 56.11 56.40 56.51 56.29 55.15 56.51 56.39 57.22 55.80 2.2% 2.2% 2.1% 2.6% 2.2% 2.2% 2.9% 3.1% 3.3% 1.9% 1.7% 1.6% MISTY MEADOW DR LOT 10 LOT 11 BLOCK 4 BLOCK 1 TRACT C FUTURE PUBLIC PARK PEDESTRIAN ACCESS EASEMENT ZEPHYR RD 30' FL-FL 53' ROW 75' CROWN TRANSITION 57.38 56.66 55.77 56.97 56.96 2.1% 2.2% 56.17 56.24 2.0% 1.2% 2.0% 0.9% 2.0% 2.0% 1.4% 2.0% 2.2% 2.3% 2.2% 0.7% 0.8% 2.6% 2.2% 1.0% 2.2% 2.0% 2.1% 0.2% 54' FL-FL 76' ROW 4.5' SIDEWALK 5' SIDEWALK 4.5' SIDEWALK 8' CROSSPAN 55.67 2.8% 2.3% 55.11 55.23 55.99 55.82 56.17 55.62 55.92 56.26 55.55 55.65 56.47 56.38 56.35 57.10 56.99 56.31 57.19 57.05 57.41 57.32 56.83 56.92 55.74 56.25 56.45 55.25 55.86 55.76 55.96 55.82 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP INT2 INTERSECTION DETAILS 50 A G H G CUL-DE-SAC DETAIL H CUL-DE-SAC DETAIL K C D E F L I J B E INTERSECTION DETAIL F INTERSECTION DETAIL NORTH M 2.2% 3.0% 2.0% 1.2% 1.2% 0.5% 64.75 65.16 64.75 2.2% 2.2% 0.2% 1.0% 63.94 63.81 1.4% 1.3% 2.7% 2.7% 2.8% 1.0% 1.5% 2.6% 64.27 64.66 64.31 2.0% 1.8% 63.86 64.16 63.99 0.4% 1.4% 1.9% 1.7% 1.5% 1.3% 1.0% 1.8% 2.0% 2.0% 2.0% 0.9% 2.0% 2.0% 30' FL-FL 53' ROW 4.5' SIDEWALK 6' CROSSPAN 62.82 1.6% 63.17 62.82 2.4% 63.27 62.19 62.24 2.0% 2.4% 62.64 63.42 64.08 63.51 64.24 64.40 63.98 64.07 64.49 64.16 63.18 63.27 63.96 63.80 63.89 64.05 2.0% 1.5% 64.85 63.81 64.76 63.72 63.62 63.53 64.42 64.33 64.12 64.63 64.60 64.08 64.73 64.70 VAULT LOT 16 MISTY MEADOW DR R50' 65.56 66.06 65.40 65.64 65.01 0.0% 1.0% 0.5% 1.0% 1.0% 63.99 4.5' SIDEWALK 4.5' SIDEWALK LOT 17 LOT 5 LOT 4 LOT 6 LOT 3 LOT 6 BLOCK 10 BLOCK 11 65.64 66.06 2.2% 2.3% 65.16 0.5% 0.5% 2.0% R50' 2.3% 2.7% 2.3% 3.0% 2.1% 2.1% 2.0% 65.01 64.35 64.30 64.82 64.86 64.96 64.91 1.2% 5' TRAIL R62' LOT 1 LOT 8 LOT 7 LOT 9 LOT 16 BLOCK 12 BLOCK 11 BLOCK 10 TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT 70.88 71.24 71.26 70.86 71.64 71.22 70.85 71.27 71.29 2.2% 2.1% 2.2% 2.2% 1.0% 2.2% 2.2% 0.9% 1.0% 72.29 72.78 72.29 2.3% 2.2% 2.2% 2.2% 2.2% 2.2% 65' CROWN TRANSITION MISTY MEADOW DR 30' FL-FL 53' ROW 71.26 72.18 71.71 71.71 36' FL-FL 59' ROW FALLEN BRANCH DR 2.1% 2.3% 2.4% 1.7% 2.4% 71.07 71.07 2.1% 71.75 1.9% 2.1% 1.3% 1.1% 1.0% 1.2% 2.1% 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 6' CROSSPAN 72.00 71.90 71.79 71.57 71.31 71.22 71.53 71.21 71.15 71.66 70.97 71.57 71.48 70.91 71.15 71.20 71.67 71.76 71.57 2.3% 0.9% 1.1% 70.87 0.9% 71.26 71.35 72.06 71.88 70.93 71.00 71.43 71.51 71.58 71.52 VAULT VAULT 65.10 64.46 64.46 65.52 65.10 65.48 65.71 65.90 2.2% 2.2% 0.5% 0.5% 2.2% 2.2% 0.3% 0.5% 0.5% 0.6% 0.5% 0.5% 2.0% 62.87 63.39 62.90 1.3% 65.29 0.4% 0.4% 0.4% 2.0% 2.0% 64.92 65.35 30' FL-FL 80' CROWN TRANSITION 2.0% 2.2% 4.3% 2.0% 2.2% 64.98 2.2% 2.2% 63.66 64.18 63.72 1.8% 2.2% 64.28 64.80 64.34 1.8% 2.2% 3.1% 3.3% 2.4% 2.4% 3.2% 2.4% 2.0% MISTY MEADOW DR 30' FL-FL 53' ROW FLYING MALLARD DR 36' FL-FL 57' FL-FL LOT 13 LOT 12 LOT 15 LOT 1 BLOCK 15 BLOCK 14 BLOCK 12 BLOCK 12 4.5' SIDEWALK 4.5' SIDEWALK 65.44 65.95 65.42 65.93 66.04 66.02 64.53 64.63 65.28 65.16 65.25 65.37 65.58 65.67 65.03 64.94 64.53 65.23 65.36 64.62 65.48 65.35 65.26 65.57 65.70 65.36 65.03 64.99 66.10 66.01 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP INT1 INTERSECTION DETAILS 49 A G H A CUL-DE-SAC DETAIL B INTERSECTION DETAIL C D K C D E F L I J B NORTH INTERSECTION DETAIL INTERSECTION DETAIL M FO FO FO FO FO FO FO FO E E E E E E E E E E E E T T T T T T T T T T T T W W W W W W W W S T 0 P ### XXX ST S T 0 P ### XXX ST 0 P T S ### XXX ST P 0 S T ### XXX ST S T 0 P ### XXX ST P 0 S T ### XXX ST P 0 S T ### XXX ST S T 0 P ### XXX ST S T 0 P ### XXX ST S T 0 P ### XXX ST NO PARKING 25 SPEED LIMIT P 0 S T ### XXX ST S T 0 P ### XXX ST 0 P T S ### XXX ST T 0 P S ### XXX ST MISTY MEADOW DR DANCING CATTAIL DR CROAKING TOAD DR WINDY WILLOW DR MISTY MEADOW DR ZEPHYR RD FALLEN BRANCH DR AUTUMN BREEZE CT MISTY MEADOW DR ROSEN DRIVE FLYING MALLARD DR X SS WM UD UD UD UD BLOCK 2 BLOCK 15 BLOCK 16 BLOCK 1 BLOCK 7 BLOCK 5 BLOCK 4 BLOCK 12 BLOCK 12 BLOCK 10 BLOCK 11 BLOCK 8 BLOCK 13 BLOCK 14 BLOCK 6 BLOCK 3 BLOCK 3 BLOCK 10 BLOCK 9 NO PARKING S T 0 P ### XXX ST 0 P T S ### XXX ST S T 0 P ### XXX ST FIRE LANE BY ORDER OF THE FIRE MARSHAL NO PARKING NO PARKING B M KEYMAP Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH ( IN FEET ) 0 1 INCH = 80 FEET 80 80 160 240 R15 SIGNAGE PLAN 48 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE DEAD END BARRICADE DEAD END BARRICADE 5' SIDEWALK 5' BIKE 5' BIKE 8' PARKING A VAULT VAULT VAULT 9' UTILITY EASEMENT PROPOSED 76' ROW PROPOSED 54' FL-FL 11' TRAVEL 11' TRAVEL ZEPHYR RD A ROSEN DRIVE "NO PARKING" SIGNS "NO PARKING TO CORNER" SIGN 13' 13' 8' PARKING SIGHT DISTANCE TRIANGLE 310' @ 30 MPH (DESIGN) SIGHT DISTANCE TRIANGLE 310' @ 30 MPH (DESIGN) MISTY MEADOW DR 5 5 3 3 5 5 16" W 16" W 16" W 16" W CTV CTV CTV CTV FO T 8" W T S T S E E E E E E E / / / / / / / / / / / / / / / / VAULT VAULT T VAULT TELE FO FO FO FO FO FO FO FO FO FO FO T T T T T T T T T T T ZEPHYR RD 5' SIDEWALK 9' UTILITY EASEMENT 5' SIDEWALK 9' UTILITY EASEMENT PLANNED HANSEN FARM TIMBERLINE ROAD BURLEY TREE DRIVE 11' TRAVEL 5' BIKE 5' BIKE 8' PARKING 8' PARKING EXISTING STRIPING PROPOSED 76' ROW DITCH LATERAL PLANNED 76' ROW PLANNED 54' FL-FL 15' EASEMENT REC. NO. 20140004033 VAULT VAULT PROPOSED 54' FL-FL 11' TRAVEL PLANNED "25 MPH SPEED LIMIT" SIGN ZEPHYR RD SIGHT DISTANCE TRIANGLE 310' @ 30 MPH (DESIGN) 12' TRAVEL LANE 12' TRAVEL LANE 6' BIKE LANE 12' TWLTL 6' BIKE LANE PLANNED "STOP" SIGN w/ STREET NAMES PLANNED "EMERGENCY ACCESS ONLY" SIGN 5 5 5 5 3 3 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 LINE MATCH STA 24+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE LINE MATCH STA 24+00 LINE MATCH STA 19+50 NORTH B M KEYMAP G G 8" SOLID WHITE LINE (2) 4" SOLID LINES; 4" APART DOUBLE YELLOW LINE DOUBLE YELLOW LINE 4" SOLID LINE, 4" DASHED LINE; 4" APART STRIPING LEGEND: PAVEMENT STRIPING AND MARKINGS: 6" SOLID WHITE LINE PREFORMED PLASTIC PAVEMENT MARKING BICYCLIST AND ARROW 1 3 4 5 A 2 8" DASHED WHITE LINE PREFORMED PLASTIC PAVEMENT MARKING 24" WIDE STOP BAR PREFORMED PLASTIC PAVEMENT MARKING RIGHT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING LEFT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING "ONLY" (22.5 S.F. EA.) C B D E 3' STRIPE, 9' GAP 6 6" DOTTED WHITE LINE 7 4" SOLID YELLOW LINE F 18" x 12' CROSS-WALK ON LANE LINES 3' STRIPE, 9' GAP 8 4" WHITE LINE 10' STRIPE, 30' GAP R14 STRIPING PLAN ZEPHYR RD 47 LINE MATCH STA 19+50 G STA.=21+79.20 INV.=4948.83 1.05% -1.63% PVI STA = 24+33.12 PVI ELEV = 4955.44 PVI STA = 24+52.87 PVI ELEV = 4955.65 PVI STA = 25+07.86 PVI ELEV = 4954.76 1.05% -1.63% PVI STA = 24+33.12 PVI ELEV = 4955.44 PVI STA = 24+52.87 PVI ELEV = 4955.65 PVI STA = 25+07.86 PVI ELEV = 4954.76 TIE TO EXISTING ROADWAY STA.=24+33.12 EL. = 4955.443 EXISTING GROUND H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC S S X X SS SS SS SS SS E G G G T T T W W W W W W RED WILLOW DR ROSEN DRIVE PROPOSED "STOP" SIGN w/ STREET NAMES 13' PROJECTED FL "25 MPH SPEED LIMIT" SIGN VAULT VAULT VAULT S SS SS T W W STA. = 20+55.65 (ZEPHYR RD) STA. = 27+57.92 (MISTY MEADOW DRIVE) 5' SIDEWALK 9' UTILITY EASEMENT PROPOSED VERTICAL CURB AND GUTTER MISTY MEADOW DR SEE SHEET R3 VAULT VAULT VAULT 9' UTILITY EASEMENT 76' ROW 54' FL-FL ZEPHYR RD ROSEN DRIVE "NO PARKING" SIGNS "NO PARKING TO CORNER" SIGN 13' PROJECTED FL 13' SIGHT DISTANCE TRIANGLE 310' @ 30 MPH (DESIGN) SIGHT DISTANCE TRIANGLE 310' @ 30 MPH (DESIGN) ∆ ∆ ∆ STORM DRAIN 2 SEE SHEET ST2 STORM DRAIN 1 SEE SHEET ST1 5' SIDEWALK 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 29+00 28+00 27+00 26+00 25+00 24+00 23+00 22+00 21+00 20+00 19+50 -0.50% 0.50% 0.50% 2.29% PVI STA = 21+94.03 PVI ELEV = 4953.62 PVI STA = 22+29.56 PVI ELEV = 4953.79 PVI STA = 23+87.21 PVI ELEV = 4955.64 197.6' VC PVI STA = 20+65.99 PVI ELEV = 4954.26 BCVS: 19+67.22 BVCE: 4958.06 ECVS: 21+64.77 EVCE: 4953.76 A.D. = 3.35 K = 58.97 107.7' VC PVI STA = 23+28.43 PVI ELEV = 4954.29 BCVS: 22+74.60 BVCE: 4954.02 ECVS: 23+82.25 EVCE: 4955.52 A.D. = 1.79 K = 60.00 4956.89 4954.44 4953.65 4954.20 4957.76 4956.12 4955.45 4954.89 4954.09 4953.85 4953.71 4953.77 4953.90 4954.02 4954.48 4954.87 4955.36 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 15" RCP STA.=21+54.52 INV.=4949.00 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 29+00 28+00 27+00 26+00 25+00 24+00 23+00 22+00 21+00 20+00 19+50 4957.53 4955.05 4953.83 4953.84 4954.45 4958.34 4956.79 4956.13 4955.55 4954.63 4954.28 4954.02 4953.70 4953.59 4953.72 4953.97 4954.09 4954.22 4954.69 4954.93 4955.09 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 15" RCP STA.=22+03.88 INV.=4948.66 0.50% -0.50% 0.50% 0.98% 0.58% PVI STA = 22+48.32 PVI ELEV = 4953.58 PVI STA = 22+89.79 PVI ELEV = 4953.79 PVI STA = 23+78.39 PVI ELEV = 4954.23 PVI STA = 24+53.44 PVI ELEV = 4954.97 PVI STA = 24+75.49 PVI ELEV = 4955.10 223.0' VC PVI STA = 20+96.06 PVI ELEV = 4954.34 BCVS: 19+84.56 BVCE: 4958.02 ECVS: 22+07.56 EVCE: 4953.79 A.D. = 2.80 K = 79.64 -0.47% -1.40% -1.63% PVI STA = 24+75.49 PVI ELEV = 4955.10 PVI STA = 24+94.00 PVI ELEV = 4955.01 PVI STA = 25+30.39 PVI ELEV = 4954.50 PVI STA = 25+52.22 PVI ELEV = 4954.15 -0.47% -1.40% -1.63% PVI STA = 24+75.49 PVI ELEV = 4955.10 PVI STA = 24+94.00 PVI ELEV = 4955.01 PVI STA = 25+30.39 PVI ELEV = 4954.50 PVI STA = 25+52.22 PVI ELEV = 4954.15 TIE TO EXISTING ROADWAY STA.=24+75.49 EL. = 4955.096 EXISTING GROUND NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 LINE MATCH STA 24+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE LINE MATCH STA 24+00 LINE MATCH STA 19+50 NORTH CENTERLINE ZEPHYR RD SCALE : 1" = 40' (H) 1" = 5' (V) B M KEYMAP G G R13 PLAN AND PROFILE ZEPHYR RD 46 LEFT FLOWLINE ZEPHYR RD SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE ZEPHYR RD SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R12 STA 19+50 G GROUND PROPOSED GRADE -1.50% 3.00% -3.50% PVI STA = 10+19.73 PVI ELEV = 4962.45 PVI STA = 18+69.31 PVI ELEV = 4962.49 390.0' VC HIGH PT ELEV = 4969.30 HIGH PT STA = 15+70.00 PVI STA = 15+85.00 PVI ELEV = 4972.45 A.D. = 6.50 K = 60.00 BVCS: 13+90 BVCE: 4966.60 EVCS: 17+80 EVCE: 4965.62 270.0' VC LP ELEV = 4961.48 LP STA = 11+29.50 PVI STA = 11+74.50 PVI ELEV = 4960.13 BCVS: 10+39.50 BVCE: 4962.16 ECVS: 13+09.50 EVCE: 4964.18 A.D. = 4.50 K = 60.00 PROPOSED GRADE EXISTING GROUND / / / / / / / / / / / / / / / / 16" W 16" W 16" W 16" W CTV CTV CTV CTV FO T 8" W T S T S E E E E E E E VAULT VAULT T ZEPHYR RD 5' SIDEWALK 9' UTILITY EASEMENT 5' SIDEWALK 9' UTILITY EASEMENT PLANNED HANSEN FARM TIMBERLINE ROAD BURLEY TREE DRIVE PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER 76' ROW DITCH LATERAL 76' ROW 54' FL-FL 15' EASEMENT REC. NO. 20140004033 VAULT VAULT 54' FL-FL PLANNED "25 MPH SPEED LIMIT" SIGN ZEPHYR RD SIGHT DISTANCE TRIANGLE 310' @ 30 MPH (DESIGN) 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 19+50 19+00 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 -1.30% -0.90% -0.50% 0.50% 3.00% -3.50% PVI STA = 10+66.74 PVI ELEV = 4961.25 PVI STA = 10+79.50 PVI ELEV = 4961.09 PVI STA = 11+04.50 PVI ELEV = 4960.86 PVI STA = 11+29.50 PVI ELEV = 4960.74 PVI STA = 18+69.31 PVI ELEV = 4961.83 150.0' VC PVI STA = 12+34.50 PVI ELEV = 4961.26 BCVS: 11+59.50 BVCE: 4960.89 ECVS: 13+09.50 EVCE: 4963.51 A.D. = 2.50 K = 60.00 -1.30% -0.90% -0.50% 0.50% 3.00% -3.50% PVI STA = 10+66.74 PVI ELEV = 4961.25 PVI STA = 10+79.50 PVI ELEV = 4961.09 PVI STA = 11+04.50 PVI ELEV = 4960.86 PVI STA = 11+29.50 PVI ELEV = 4960.74 PVI STA = 18+69.31 PVI ELEV = 4961.83 390.0' VC HIGH PT ELEV = 4968.63 HIGH PT STA = 15+70.00 PVI STA = 15+85.00 PVI ELEV = 4971.78 A.D. = 6.50 K = 60.00 BVCS: 13+90 BVCE: 4965.93 EVCS: 17+80 EVCE: 4964.95 150.0' VC PVI STA = 12+34.50 PVI ELEV = 4961.26 BCVS: 11+59.50 BVCE: 4960.89 ECVS: 13+09.50 EVCE: 4963.51 A.D. = 2.50 K = 60.00 4961.15 4960.90 4960.76 4960.84 4960.99 4961.23 4961.57 4962.02 4962.58 4963.24 4963.98 4964.73 4965.48 4966.22 4966.88 4967.43 4967.88 4968.22 4968.46 4968.60 4968.63 4968.55 4968.38 4968.10 4967.71 4967.22 4966.63 4965.93 4965.13 4964.25 4963.38 4962.50 4961.61 4960.65 4959.68 PROPOSED GRADE EXISTING GROUND PLANNED GRADE EXISTING GROUND PLANNED GRADE TIE TO PLANNED CURB AND GUTTER STA.=14+96.04 EL. = 4968.162 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 19+50 19+00 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 -0.68% -0.50% 0.50% 3.00% -3.50% PVI STA = 10+78.26 PVI ELEV = 4961.03 PVI STA = 10+99.50 PVI ELEV = 4960.89 PVI STA = 11+29.50 PVI ELEV = 4960.74 PVI STA = 18+69.31 PVI ELEV = 4961.83 150.0' VC PVI STA = 12+34.50 PVI ELEV = 4961.26 BCVS: 11+59.50 BVCE: 4960.89 ECVS: 13+09.50 EVCE: 4963.51 A.D. = 2.50 K = 60.00 -0.68% -0.50% 0.50% 3.00% -3.50% PVI STA = 10+78.26 PVI ELEV = 4961.03 PVI STA = 10+99.50 PVI ELEV = 4960.89 PVI STA = 11+29.50 PVI ELEV = 4960.74 PVI STA = 18+69.31 PVI ELEV = 4961.83 390.0' VC HIGH PT ELEV = 4968.63 HIGH PT STA = 15+70.00 PVI STA = 15+85.00 PVI ELEV = 4971.78 A.D. = 6.50 K = 60.00 BVCS: 13+90 BVCE: 4965.93 EVCS: 17+80 EVCE: 4964.95 150.0' VC PVI STA = 12+34.50 PVI ELEV = 4961.26 BCVS: 11+59.50 BVCE: 4960.89 ECVS: 13+09.50 EVCE: 4963.51 A.D. = 2.50 K = 60.00 4960.89 4961.23 4963.24 4966.22 4968.22 4968.55 4967.22 4964.25 4960.81 4960.76 4960.84 4960.99 4961.57 4962.02 4962.58 4963.98 4964.73 4965.48 4966.88 4967.43 4967.88 4968.46 4968.60 4968.63 4968.38 4968.10 4967.71 4966.63 4965.93 4965.13 4963.38 4962.50 4961.64 4959.99 PLANNED GRADE EXISTING GROUND PLANNED GRADE EXISTING GROUND PROPOSED GRADE TIE TO PLANNED CURB AND GUTTER STA.=15+50.27 EL. = 4968.595 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH LINE MATCH STA 19+50 CENTERLINE ZEPHYR RD SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP G G R12 PLAN AND PROFILE ZEPHYR RD 45 LEFT FLOWLINE ZEPHYR RD SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE ZEPHYR RD SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R13 STA 19+50 E E E E E E E E E G G G G G G G G G G G G G G G G E E E E E G G G G E E E E E E E E E G G G G G VAULT VAULT VAULT VAULT VAULT E E E E E E E E E E E WINDY WILLOW DR LOT 2 BLOCK 5 18.58' FL-EOC PROPOSED DRIVE OVER CURB AND GUTTER PROPOSED 1' CONCRETE RIBBON DANCING CATTAIL DR STA. = 16+14.53 (ALLEY 2) STA. = 18+16.70 (DANCING CATTAIL DR) STORM DRAIN 1 SEE SHEET ST1 PRIVATE ALLEY 2 MISTY MEADOW DR 9' UTILITY EASEMENT 4.5' SIDEWALK ∆ STA. = 10+00.00 (ALLEY 2) STA. = 22+49.95 (MISTY MEADOW DR) 5' TRAIL 5' TRAIL PROPOSED 2' SIDEWALK CHASE 4945 4950 4955 4960 4965 4970 4975 4945 4950 4955 4960 4965 4970 4975 16+50 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 1.03% PROPOSED GRADE EXISTING GROUND -5.23% -5.22% -0.50% -4.83% -4.83% -1.26% -0.90% PVI STA = 10+26.70 PVI ELEV = 4965.62 PVI STA = 10+56.70 PVI ELEV = 4964.17 PVI STA = 11+92.15 PVI ELEV = 4957.34 PVI STA = 14+23.95 PVI ELEV = 4950.63 PVI STA = 14+48.95 PVI ELEV = 4950.40 PVI STA = 15+78.08 PVI ELEV = 4949.76 PVI STA = 15+80.91 PVI ELEV = 4949.76 PVI STA = 15+88.03 PVI ELEV = 4949.83 35.4' VC PVI STA = 11+16.44 PVI ELEV = 4961.29 A.D. = 0.38 K = 92.23 BVCS: 10+98.76 BVCE: 4962.14 EVCS: 11+34.12 EVCE: 4960.36 84.7' VC PVI STA = 12+87.61 PVI ELEV = 4952.34 BCVS: 12+45.27 BVCE: 4954.56 ECVS: 13+29.94 EVCE: 4951.81 A.D. = 3.98 K = 21.28 4963.29 4962.08 4960.83 4959.54 4958.23 4956.93 4955.62 4954.31 4953.21 4952.39 4951.88 4951.56 4951.24 4950.93 4950.62 4950.40 4950.27 4950.15 4950.02 4949.90 4949.77 PROPOSED GRADE EXISTING GROUND 24" RCP STORM STA.=12+40.86 INV.=4947.11 PROPOSED 2' CURB CUT STA.=15+79.49 EL. = 4949.758 B M KEYMAP NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE R11 PLAN AND PROFILE PRIVATE ALLEY 2 44 RIGHT FLOWLINE PRIVATE ALLEY 2 SCALE : 1" = 40' (H) 1" = 5' (V) ALLEY 2 PVI ELEV = 4947.35 PVI STA = 17+64.38 PVI ELEV = 4948.26 PVI STA = 12+71.38 PVI ELEV = 4954.40 PVI STA = 15+48.01 PVI ELEV = 4947.10 PVI STA = 15+94.38 PVI ELEV = 4947.34 PVI STA = 15+35.98 PVI ELEV = 4947.10 PVI STA = 15+42.05 PVI ELEV = 4947.07 75.0' VC PVI STA = 10+84.80 PVI ELEV = 4964.08 A.D. = 3.19 K = 23.51 BVCS: 10+47.30 BVCE: 4964.83 EVCS: 11+22.30 EVCE: 4962.14 100.0' VC PVI STA = 13+90.94 PVI ELEV = 4947.96 BCVS: 13+40.94 BVCE: 4950.65 ECVS: 14+40.94 EVCE: 4947.64 A.D. = 4.74 K = 21.08 18.58' FL-EOC MISTY MEADOW DR DANCING CATTAIL DR LOT 8 LOT 9 LOT 5 LOT 2 LOT 89 LOT 10 LOT 11 LOT 15 LOT 13 LOT 14 LOT 1 LOT 2 LOT 4 LOT 3 LOT 5 LOT 6 LOT 7 LOT 1 LOT 1 LOT 2 LOT 3 LOT 68 LOT 4 LOT 15 LOT 11 LOT 9 LOT 10 LOT 12 LOT 74 LOT 13 LOT 14 LOT 17 LOT 16 LOT 3 LOT 6 LOT 7 LOT 82 LOT 5 LOT 4 LOT 1 LOT 2 LOT 8 LOT 12 TRACT H TRACT G TRACT F TRACT P TRACT Q FLYING MALLARD DR PROPOSED DRIVE OVER CURB AND GUTTER BLOCK 14 BLOCK 15 BLOCK 13 E E E E E E E E E E E E E G G G G G G G G G G G G E E E E E E E E E E E E E E G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G VAULT VAULT VAULT VAULT VAULT E E E E E E E E E E E E E E E 9' UTILITY EASEMENT 4.5' SIDEWALK PRIVATE ALLEY 1 STA. = 10+00.00 (ALLEY 1) STA. = 20+08.95 (MISTY MEADOW DR) PROPOSED 1' CONCRETE RIBBON ∆ PROPOSED 12' CONCRETE PAN STORM DRAIN 1 SEE SHEET ST1 5' TRAIL 5' TRAIL TRACT S DUA STA. = 17+90.89 (ALLEY 1) STA. = 15+75.70 (DANCING CATTAIL DR) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH RIGHT FLOWLINE PRIVATE ALLEY 1 SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP ALLEY 1 R10 PLAN AND PROFILE PRIVATE ALLEY 1 43 TIE TO EXISTING STA.=12+12.40 EL. = 4971.644 FO FO FO FO FO FO E E E E E E FALLEN BRANCH DR 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT LOT 1 LOT 8 LOT 6 LOT 7 LOT 9 LOT 16 LOT 15 STA. = 10+00.00 (FALLEN BRANCH DRIVE) STA. = 14+96.68 (MISTY MEADOW DRIVE) MISTY MEADOW DR SEE SHEET R1 MISTY MEADOW DR SEE SHEET R2 PROPOSED DRIVE OVER CURB AND GUTTER PLANNED HANSEN FARM PLANNED HANSEN FARM PLANNED 24"x36" RCBC BLOCK 12 BLOCK 11 BLOCK 10 TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT DITCH LATERAL "STOP" SIGN W/ STREET NAMES KNOBBY PINE DRIVE KNOBBY PINE DRIVE 36' FL-FL 59' ROW 65' CROWN TRANSITION 30' EASEMENT REC. NO. 20140004033 15' EASEMENT REC. NO. 20110070565 4960 4965 4970 4975 4980 4985 4960 4965 4970 4975 4980 4985 9+50 10+00 11+00 12+00 13+00 13+50 -4.38% 2.00% 2.40% PVI STA = 10+34.43 PVI ELEV = 4971.24 PVI STA = 10+56.98 PVI ELEV = 4971.69 PVI STA = 13+03.12 PVI ELEV = 4967.19 136.0' VC HP ELEV = 4972.86 HP STA = 11+29.70 PVI STA = 11+49.57 PVI ELEV = 4973.91 BVCS: 10+81.57 BVCE: 4972.28 EVCS: 12+17.57 EVCE: 4970.93 A.D. = 6.78 K = 20.05 4972.12 4972.64 4972.85 4972.76 4972.35 4971.63 4970.61 4969.51 4968.42 4967.32 24"x36" STA.=12+14.98 INV.=4967.96 TIE TO EXISITNG STA.=12+12.40 EL. = 4971.153 4960 4965 4970 4975 4980 4985 4960 4965 4970 4975 4980 4985 9+50 10+00 11+00 12+00 13+00 13+50 -4.40% 2.00% 2.40% PVI STA = 10+35.58 PVI ELEV = 4971.26 PVI STA = 10+56.98 PVI ELEV = 4971.69 PVI STA = 13+03.12 PVI ELEV = 4967.19 136.0' VC HP ELEV = 4972.87 HP STA = 11+29.98 PVI STA = 11+49.98 PVI ELEV = 4973.92 BVCS: 10+81.98 BVCE: 4972.29 EVCS: 12+17.98 EVCE: 4970.93 A.D. = 6.80 K = 20.00 -4.40% 2.00% 2.40% PVI STA = 10+35.58 PVI ELEV = 4971.26 PVI STA = 10+56.98 PVI ELEV = 4971.69 PVI STA = 13+03.12 PVI ELEV = 4967.19 136.0' VC HP ELEV = 4972.87 HP STA = 11+29.98 PVI STA = 11+49.98 PVI ELEV = 4973.92 BVCS: 10+81.98 BVCE: 4972.29 EVCS: 12+17.98 EVCE: 4970.93 A.D. = 6.80 K = 20.00 4972.12 4972.64 4972.86 4972.77 4972.36 4971.64 4970.62 4969.52 4968.42 4967.32 24"x36" STA.=12+16.50 INV.=4967.90 TIE TO EXISTING STA.=12+12.40 EL. = 4971.167 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE FALLEN BRANCH DR SCALE : 1" = 40' (H) 1" = 5' (V) B M KEYMAP E R9 PLAN & PROFILE FALLEN BRANCH DR 42 LEFT FLOWLINE FALLEN BRANCH DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE FALLEN BRANCH DR SCALE : 1" = 40' (H) 1" = 5' (V) 4958.03 4953.26 4950.99 4950.43 4949.93 4965.18 4964.04 4962.17 4960.95 4959.53 4956.60 4955.33 4952.46 4951.81 4951.32 4950.81 4950.68 4950.56 4950.31 4950.18 4950.06 4949.73 4949.33 4948.83 24" RCP STA.=12+76.54 INV.=4946.66 PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE E E E E E E E E E E E E E G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G V AULT VAULT VAULT VAULT VAULT VAULT E E E E E E E E E E E E E E MISTY MEADOW DR SEE SHEET R2 DANCING CATTAIL DR SEE SHEET R4 LOT 9 LOT 5 LOT 89 LOT 10 LOT 11 LOT 15 LOT 13 LOT 14 LOT 1 LOT 2 LOT 4 LOT 3 LOT 5 LOT 9 LOT 6 LOT 7 LOT 8 LOT 12 LOT 10 LOT 11 LOT 13 LOT 7 LOT 6 LOT 12 LOT 11 LOT 3 LOT 6 LOT 7 LOT 82 LOT 5 LOT 4 LOT 1 LOT 2 LOT 8 LOT 12 TRACT I TRACT H TRACT G TRACT Q TRACT S DUA PROPOSED VERTICAL CURB AND GUTTER BLOCK 14 BLOCK 15 BLOCK 16 TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT 4.5' SIDEWALK STORM DRAIN 1 SEE SHEET ST1 FLYING MALLARD DR 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT TRACT D DUA&EAE STA. = 10+00.00 (FLYING MALLARD DR) STA. = 21+38.04 (MISTY MEADOW DR) BLOCK 6 STA. = 16+96.43 (FLYING MALLARD DR) STA. = 17+04.78 (DANCING CATTAIL DR) DANCING CATTAIL DR SEE SHEET R4 MISTY MEADOW DR SEE SHEET R2 57' ROW 36' FL-FL ∆ ∆ ∆ 80.00' CROWN TRANSITION 75.00' CROWN TRANSITION 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+25 -6.25% -2.10% -0.50% -0.74% PVI STA = 10+35.00 PVI ELEV = 4964.54 PVI STA = 16+06.34 PVI ELEV = 4949.31 PVI STA = 16+48.26 PVI ELEV = 4949.00 124.0' VC PVI STA = 11+09.30 PVI ELEV = 4962.98 BVCS: 10+47.30 BVCE: 4964.28 EVCS: 11+71.30 EVCE: 4959.10 A.D. = 4.15 K = 29.88 214.0' VC PVI STA = 13+03.74 PVI ELEV = 4950.83 BCVS: 11+96.74 BVCE: 4957.51 ECVS: 14+10.74 EVCE: 4950.29 A.D. = 5.75 K = 37.22 4964.22 4963.57 4962.71 4961.64 4960.36 4958.87 4957.31 4955.86 4954.57 4953.45 4952.49 4951.71 4951.09 4950.64 4950.36 4950.22 4950.10 4949.97 4949.85 4949.72 4949.60 4949.47 4949.35 4949.18 PROPOSED GRADE EXISTING GROUND EXISTING GROUND 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+25 -5.79% -0.50% -1.26% -2.00% PVI STA = 10+35.00 PVI ELEV = 4964.46 PVI STA = 16+74.60 PVI ELEV = 4948.83 130.0' VC PVI STA = 11+08.35 PVI ELEV = 4962.99 BVCS: 10+43.35 BVCE: 4964.29 EVCS: 11+73.35 EVCE: 4959.23 A.D. = 3.79 K = 34.33 49.8' VC PVI STA = 16+39.68 PVI ELEV = 4949.27 BVCS: 16+14.77 BVCE: 4949.39 EVCS: 16+64.58 EVCE: 4948.95 A.D. = 0.76 K = 65.38 228.1' VC PVI STA = 13+17.72 PVI ELEV = 4950.88 BCVS: 12+03.67 BVCE: 4957.48 ECVS: 14+31.77 EVCE: 4950.31 A.D. = 5.29 K = 43.14 4964.15 4963.51 4962.69 4961.69 4960.50 4959.14 4957.69 4956.30 4955.04 4953.94 4952.98 4952.16 4951.49 4950.96 4950.58 4950.35 4950.22 4950.09 4949.97 4949.84 4949.72 4949.59 4949.47 4949.33 4949.12 PROPOSED GRADE EXISTING GROUND EXISTING GROUND CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH CENTERLINE FLYING MALLARD DR SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP D R8 PLAN AND PROFILE FLYING MALLARD DR 41 LEFT FLOWLINE FLYING MALLARD DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE FLYING MALLARD DR SCALE : 1" = 40' (H) 1" = 5' (V) A.D. = 1.00 K = 75.00 75.0' VC LP ELEV = 4946.07 LP STA = 24+73.58 PVI STA = 24+73.58 PVI ELEV = 4945.98 BCVS: 24+36.08 BVCE: 4946.17 ECVS: 25+11.08 EVCE: 4946.17 A.D. = 1.00 K = 75.00 0.50% -0.50% 0.50% PVI STA = 26+77.39 PVI ELEV = 4947.00 75.0' VC HP ELEV = 4948.18 HP STA = 20+15.87 PVI STA = 20+15.87 PVI ELEV = 4948.27 BVCS: 19+78.37 BVCE: 4948.08 EVCS: 20+53.37 EVCE: 4948.08 A.D. = 1.00 K = 75.00 75.0' VC LP ELEV = 4946.07 LP STA = 24+73.58 PVI STA = 24+73.58 PVI ELEV = 4945.98 BCVS: 24+36.08 BVCE: 4946.17 ECVS: 25+11.08 EVCE: 4946.17 A.D. = 1.00 K = 75.00 4948.16 4947.85 4947.35 4946.85 4946.35 4946.12 4946.61 4947.82 4947.94 4948.07 4948.17 4948.10 4947.97 4947.72 4947.60 4947.47 4947.22 4947.10 4946.97 4946.72 4946.60 4946.47 4946.22 4946.11 4946.07 4946.24 4946.36 4946.49 4946.74 4946.86 4946.99 FUTURE GRADE (TO REMAIN HIGH AS EMERGENCY OUTFALL ELEVATION FOR SITE IS ESTIMATED TO BE APPROXIMATELY 4945') EXISTING GROUND PROPOSED GRADE EXISTING GROUND END PROPOSED ROADWAY STA.=20+04.28 EL. = 4948.167 PROPOSED GRADE FUTURE GRADE EXISTING GROUND FUTURE GRADE EXISTING GROUND STREET C Right Flowline 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 4947.76 4947.38 4946.88 4946.38 4945.88 4945.75 4946.25 4947.45 4947.58 4947.70 4947.73 4947.63 4947.50 4947.25 4947.13 4947.00 4946.75 4946.63 4946.50 4946.25 4946.13 4946.00 4945.75 4945.67 4945.67 4945.87 4946.00 4946.12 4946.37 4946.50 PROPOSED GRADE EXISTING GROUND EXISTING GROUND END PROPOSED CURB AND GUTTER STA.=19+93.32 EL. = 4947.746 0.50% 0.50% -0.50% PVI STA = 26+66.41 PVI ELEV = 4946.58 75.0' VC HP ELEV = 4947.76 HP STA = 20+04.90 PVI STA = 20+04.90 PVI ELEV = 4947.85 BVCS: 19+67.40 BVCE: 4947.66 EVCS: 20+42.40 EVCE: 4947.66 A.D. = 1.00 K = 75.00 75.0' VC LP ELEV = 4945.66 LP STA = 24+62.60 PVI STA = 24+62.60 PVI ELEV = 4945.56 BCVS: 24+25.10 BVCE: 4945.75 ECVS: 25+00.10 EVCE: 4945.75 A.D. = 1.00 K = 75.00 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 4947.71 4947.48 4946.98 4946.48 4945.98 4945.67 4946.14 4947.34 4947.47 4947.59 4947.76 4947.72 4947.61 4947.36 4947.23 4947.11 4946.86 4946.73 4946.61 4946.36 4946.23 4946.11 4945.86 4945.74 4945.66 4945.76 4945.89 4946.01 4946.26 4946.39 4946.51 0.50% -0.50% 0.50% PVI STA = 26+88.37 PVI ELEV = 4946.58 75.0' VC HP ELEV = 4947.76 HP STA = 20+26.85 PVI STA = 20+26.85 PVI ELEV = 4947.85 BVCS: 19+89.35 BVCE: 4947.66 EVCS: 20+64.35 EVCE: 4947.66 A.D. = 1.00 K = 75.00 75.0' VC LP ELEV = 4945.66 LP STA = 24+84.56 PVI STA = 24+84.56 PVI ELEV = 4945.56 BCVS: 24+47.06 BVCE: 4945.75 ECVS: 25+22.06 EVCE: 4945.75 A.D. = 1.00 K = 75.00 PROPOSED GRADE EXISTING GROUND EXISTING GROUND END PROPOSED CURB AND GUTTER STA.=20+15.28 EL. = 4947.752 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 LINE MATCH STA 19+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE CROAKING TOAD DR SCALE : 1" = 40' (H) 1" = 5' (V) B M KEYMAP R7 PLAN AND PROFILE CROAKING TOAD DR 40 C C LEFT FLOWLINE CROAKING TOAD DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE CROAKING TOAD DR SCALE : 1" = 40' (H) 1" = 5' (V) E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G V AULT VAULT VAULT VAULT VAULT E E E E E E E E E E E E E E E E E TRACT F PROPOSED DRIVE OVER CURB AND GUTTER 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT CROAKING TOAD DR MISTY MEADOW DR SEE SHEET R2 DANCING CATTAIL DR SEE SHEET R4 5' TRAIL 5' TRAIL TRACT G "STOP" SIGN w/ STREET NAMES BLOCK 14 STORM DRAIN 1 SEE SHEET ST1 ∆ ∆ MISTY MEADOW DR SEE SHEET R2 ALLEY 1 PROPOSED FOREBAY (SEE DETAIL SHEET D4 ) 75' CROWN TRANSITION 75' CROWN TRANSITION 4940 4945 4950 4955 4960 4965 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 4963.96 4962.26 4958.10 4953.55 4949.09 4946.90 4945.95 4946.69 4947.19 4963.68 4963.34 4962.90 4961.42 4960.38 4959.24 4956.96 4955.83 4954.69 4952.41 4951.28 4950.14 4948.24 4947.60 4947.15 4946.77 4946.64 4946.39 4945.63 4946.13 4946.50 4946.82 4946.94 4947.07 4947.32 4947.44 4947.57 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND -0.95% 0.50% 2.00% 0.50% -0.50% -2.00% -4.55% -1.35% PVI STA = 10+00.00 PVI ELEV = 4963.96 PVI STA = 10+13.83 PVI ELEV = 4963.83 PVI STA = 18+72.78 PVI ELEV = 4947.55 PVI STA = 16+20.45 PVI ELEV = 4945.54 50.0' VC PVI STA = 15+70.45 PVI ELEV = 4946.54 BVCS: 15+45.45 BVCE: 4946.67 EVCS: 15+95.45 EVCE: 4946.04 A.D. = 1.50 K = 33.33 50.0' VC PVI STA = 16+70.45 PVI ELEV = 4946.54 BVCS: 16+45.45 BVCE: 4946.04 EVCS: 16+95.45 EVCE: 4946.67 A.D. = 1.50 K = 33.33 100.0' VC PVI STA = 10+99.60 PVI ELEV = 4962.67 BVCS: 10+49.60 BVCE: 4963.34 EVCS: 11+49.60 EVCE: 4960.39 A.D. = 3.20 K = 31.25 127.0' VC PVI STA = 14+39.70 PVI ELEV = 4947.20 BCVS: 13+76.20 BVCE: 4950.09 ECVS: 15+03.20 EVCE: 4946.88 A.D. = 4.05 K = 31.36 24" RCP STA.=13+58.01 INV.=4945.19 4940 4945 4950 4955 4960 4965 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 0.50% -2.00% -0.51% 0.50% -4.66% PVI STA = 10+35.00 PVI ELEV = 4963.35 PVI STA = 16+10.11 PVI ELEV = 4945.88 PVI STA = 18+61.81 PVI ELEV = 4947.14 124.3' VC PVI STA = 14+32.93 PVI ELEV = 4946.78 BCVS: 13+70.79 BVCE: 4949.67 ECVS: 14+95.08 EVCE: 4946.46 A.D. = 4.15 K = 29.97 0.50% -2.00% -0.51% 0.50% -4.66% 95.0' VC PVI STA = 11+08.64 PVI ELEV = 4961.87 BVCS: 10+61.14 BVCE: 4962.82 EVCS: 11+56.14 EVCE: 4959.66 A.D. = 2.66 K = 35.78 124.3' VC PVI STA = 14+32.93 PVI ELEV = 4946.78 BCVS: 13+70.79 BVCE: 4949.67 ECVS: 14+95.08 EVCE: 4946.46 A.D. = 4.15 K = 29.97 4961.84 4957.62 4952.97 4948.45 4946.44 4945.93 4946.33 4946.83 4963.05 4962.52 4960.98 4959.94 4958.78 4956.46 4955.29 4954.13 4951.80 4950.64 4949.48 4947.64 4947.03 4946.63 4946.31 4946.18 4946.06 4945.95 4946.08 4946.20 4946.45 4946.58 4946.70 4946.95 4947.08 4947.20 PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE 4940 4945 4950 4955 4960 4965 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 -4.45% 0.50% -1.54% 2.00% -0.50% -1.96% 0.50% 130.0' VC PVI STA = 14+46.38 PVI ELEV = 4946.78 BCVS: 13+81.38 BVCE: 4949.67 ECVS: 15+11.38 EVCE: 4946.46 A.D. = 3.95 K = 32.92 -4.45% 0.50% -1.54% 2.00% -0.50% -1.96% 0.50% PVI STA = 10+35.00 PVI ELEV = 4963.12 PVI STA = 16+30.78 PVI ELEV = 4945.11 PVI STA = 18+83.76 PVI ELEV = 4947.14 95.0' VC PVI STA = 11+02.50 PVI ELEV = 4962.08 BVCS: 10+55 BVCE: 4962.82 EVCS: 11+50 EVCE: 4959.97 A.D. = 2.91 K = 32.65 50.0' VC PVI STA = 15+79.74 PVI ELEV = 4946.12 BVCS: 15+54.74 BVCE: 4946.24 EVCS: 16+04.74 EVCE: 4945.62 A.D. = 1.46 K = 34.14 50.0' VC PVI STA = 16+81.35 PVI ELEV = 4946.12 BVCS: 16+56.35 BVCE: 4945.62 EVCS: 17+06.35 EVCE: 4946.25 A.D. = 1.50 K = 33.39 130.0' VC PVI STA = 14+46.38 PVI ELEV = 4946.78 BCVS: 13+81.38 BVCE: 4949.67 ECVS: 15+11.38 EVCE: 4946.46 A.D. = 3.95 K = 32.92 4961.81 4957.75 4953.30 4948.90 4946.53 4945.71 4946.21 4946.72 4962.89 4962.45 4960.99 4959.97 4958.86 4956.63 4955.52 4954.41 4952.18 4951.07 4949.96 4948.02 4947.34 4946.84 4946.39 4946.26 4946.08 4945.23 4945.50 4945.94 4946.34 4946.47 4946.59 4946.84 4946.97 4947.09 PROPOSED GRADE EXISTING GROUND EXISTING GROUND CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH LINE MATCH STA 19+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE CROAKING TOAD DR SCALE : 1" = 40' (H) 1" = 5' (V) B M KEYMAP C C R6 PLAN AND PROFILE CROAKING TOAD DR 39 LEFT FLOWLINE CROAKING TOAD DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE CROAKING TOAD DR SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R7 STA 19+00 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT WINDY WILLOW DR LOT 9 LOT 8 LOT 7 LOT 5 LOT 6 LOT 4 LOT 1 ∆ ∆ ∆ ∆ ∆ STA. = 17+04.78 (DANCING CATTAIL DRIVE) STA. = 16+96.43 (FLYING MALLARD DRIVE) ∆ LOT 8 LOT 9 LOT 6 LOT 3 LOT 7 LOT 4 LOT 5 LOT 10 LOT 11 TRACT T DUE BLOCK 16 BLOCK 5 E E E E E G G G G G G G G G G G G G G G E E E E E E E E E E E E E G G G G G G G G E E E E E E E E E G G G G G VAULT VAULT VAULT E E E E E PROPOSED VERTICAL CURB AND GUTTER 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT "STOP" SIGN w/ STREET NAMES WINDY WILLOW DR 57' ROW 36' FL-FL 5' TRAIL 5' TRAIL TRACT J TRACT I STA. = 24+49.90 (WINDY WILLOW DR) STA. = 23+79.04 (MISTY MEADOW DR) LOT 1 LOT 2 LOT 1 STORM DRAIN 1 SEE SHEET ST1 ∆ ∆ ∆ ∆ 121' CROWN TRANSITION 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 16+50 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 25+50 4949.08 4949.58 4950.31 4950.94 4951.45 4953.74 4958.25 4961.80 4948.96 4949.21 4949.33 4949.46 4949.71 4949.83 4950.07 4950.52 4950.71 4950.86 4951.03 4951.12 4951.23 4951.81 4952.31 4952.95 4954.66 4955.73 4956.94 4959.42 4960.40 4961.18 4962.35 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 18" RCP STORM STA.=22+50.70 INV.=4947.63 2.20% 5.30% 2.40% 2.00% 0.75% 0.50% 0.96% 0.50% 0.35% PVI STA = 24+49.90 PVI ELEV = 4962.87 PVI STA = 24+11.07 PVI ELEV = 4962.07 PVI STA = 24+36.07 PVI ELEV = 4962.57 PVI STA = 19+65.76 PVI ELEV = 4950.82 PVI STA = 18+50.25 PVI ELEV = 4949.83 PVI STA = 19+10.78 PVI ELEV = 4950.41 PVI STA = 20+60.37 PVI ELEV = 4951.16 93.0' VC PVI STA = 23+39.42 PVI ELEV = 4960.35 BVCS: 22+92.92 BVCE: 4957.88 EVCS: 23+85.92 EVCE: 4961.47 A.D. = 2.90 K = 32.03 212.0' VC PVI STA = 21+77.10 PVI ELEV = 4951.74 BCVS: 20+71.11 BVCE: 4951.21 ECVS: 22+83.08 EVCE: 4957.36 A.D. = 4.80 K = 44.12 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 16+50 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 25+50 4.97% 0.90% 0.50% 0.83% 0.50% 3.21% PVI STA = 18+50.00 PVI ELEV = 4949.40 PVI STA = 19+07.78 PVI ELEV = 4949.88 PVI STA = 19+39.20 PVI ELEV = 4950.16 PVI STA = 24+01.51 PVI ELEV = 4962.24 93.0' VC PVI STA = 23+25.59 PVI ELEV = 4959.81 BVCS: 22+79.09 BVCE: 4957.49 EVCS: 23+72.09 EVCE: 4961.30 A.D. = 1.76 K = 52.75 225.3' VC PVI STA = 21+53.12 PVI ELEV = 4951.23 BCVS: 20+40.45 BVCE: 4950.67 ECVS: 22+65.78 EVCE: 4956.83 A.D. = 4.47 K = 50.41 4948.65 4949.15 4949.82 4950.47 4951.32 4953.99 4958.49 4962.19 4948.53 4948.78 4948.90 4949.03 4949.27 4949.40 4949.61 4950.04 4950.22 4950.34 4950.59 4950.73 4950.96 4951.80 4952.41 4953.14 4954.97 4956.07 4957.29 4959.58 4960.54 4961.39 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 16+50 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 25+50 5.56% 0.50% 2.53% 0.50% PVI STA = 18+50.25 PVI ELEV = 4949.40 PVI STA = 24+38.55 PVI ELEV = 4961.71 93.0' VC PVI STA = 23+65.22 PVI ELEV = 4959.86 BVCS: 23+18.72 BVCE: 4957.27 EVCS: 24+11.72 EVCE: 4961.04 A.D. = 3.04 K = 30.63 202.6' VC PVI STA = 22+09.51 PVI ELEV = 4951.20 BCVS: 21+08.22 BVCE: 4950.69 ECVS: 23+10.79 EVCE: 4956.83 A.D. = 5.06 K = 40.00 4948.65 4949.15 4949.65 4950.15 4950.65 4952.20 4956.25 4960.72 4948.53 4948.78 4948.90 4949.03 4949.27 4949.40 4949.52 4949.77 4949.90 4950.02 4950.27 4950.40 4950.52 4950.81 4951.12 4951.58 4952.98 4953.91 4955.00 4957.62 4958.85 4959.89 4961.37 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 LINE MATCH STA 16+50 NORTH LINE MATCH STA 20+00 LINE MATCH STA 20+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE WINDY WILLOW DR SCALE : 1" = 40' (H) 1" = 5' (V) B M KEYMAP B B B2 R5 WINDY WILLOW DR PLAN AND PROFILE DANCING CATTAIL DR & 38 CENTERLINE DANCING CATTAIL DR SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE WINDY WILLOW DR SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE DANCING CATTAIL DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE WINDY WILLOW DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE DANCING CATTAIL DR SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R4 STA 16+50 G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E G G G G G G G G G G G VAULT VAULT VAULT VAULT E E VAULT DANCING CATTAIL DR AUTUMN BREEZE CT SEE SHEET INT1 CROAKING TOAD DR SEE SHEET R6 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT PROPOSED DRIVE OVER CURB AND GUTTER CURB CUT & CONCRETE RUNDOWN "STOP" SIGN w/ STREET NAMES "STOP" SIGN w/ STREET NAMES STA. = 14+63.78 (DANCING CATTAIL DRIVE) STA. = 18+72.79 (CROAKING TOAD DRIVE) STA. = 11+54.75 (DANCING CATTAIL DRIVE) STA. = 10+29.73 (AUTUMN BREEZE CT) LOT 11 LOT 10 LOT 9 LOT 13 LOT 11 LOT 8 78.00 CROWN TRANSITION 78.00 CROWN TRANSITION 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50 4946.28 4946.78 4947.28 4947.78 4948.04 4947.58 4948.58 4946.40 4946.53 4946.65 4946.90 4947.03 4947.15 4947.40 4947.53 4947.65 4947.90 4948.03 4948.15 4947.63 4947.25 4947.31 4948.04 4948.32 4948.46 4948.71 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 2.20% -2.20% 2.00% -2.00% 0.50% 0.50% PVI STA = 10+00.00 PVI ELEV = 4946.28 PVI STA = 14+43.95 PVI ELEV = 4947.25 PVI STA = 14+46.95 PVI ELEV = 4947.18 PVI STA = 14+49.95 PVI ELEV = 4947.25 PVI STA = 14+63.78 PVI ELEV = 4947.55 PVI STA = 14+77.62 PVI ELEV = 4947.25 PVI STA = 14+80.62 PVI ELEV = 4947.18 PVI STA = 14+83.62 PVI ELEV = 4947.25 50.0' VC HP ELEV = 4948.15 HP STA = 13+78.96 PVI STA = 13+93.95 PVI ELEV = 4948.25 BVCS: 13+68.95 BVCE: 4948.12 EVCS: 14+18.95 EVCE: 4947.75 A.D. = 2.50 K = 20.00 50.0' VC PVI STA = 15+33.62 PVI ELEV = 4948.25 BVCS: 15+08.62 BVCE: 4947.75 EVCS: 15+58.62 EVCE: 4948.37 A.D. = 1.50 K = 33.33 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50 0.50% -1.38% 2.50% -2.50% 1.38% 0.50% PVI STA = 10+00.00 PVI ELEV = 4945.86 PVI STA = 14+43.95 PVI ELEV = 4947.13 PVI STA = 14+46.95 PVI ELEV = 4947.06 PVI STA = 14+49.95 PVI ELEV = 4947.13 PVI STA = 14+63.78 PVI ELEV = 4947.48 PVI STA = 14+77.62 PVI ELEV = 4947.13 PVI STA = 14+80.62 PVI ELEV = 4947.06 PVI STA = 14+83.62 PVI ELEV = 4947.13 50.0' VC HP ELEV = 4947.73 HP STA = 13+82.21 PVI STA = 13+93.95 PVI ELEV = 4947.82 BVCS: 13+68.95 BVCE: 4947.70 EVCS: 14+18.95 EVCE: 4947.48 A.D. = 1.88 K = 26.58 50.0' VC PVI STA = 15+33.62 PVI ELEV = 4947.82 BVCS: 15+08.62 BVCE: 4947.48 EVCS: 15+58.62 EVCE: 4947.95 A.D. = 0.88 K = 56.83 4945.86 4946.36 4946.86 4947.36 4947.67 4947.36 4948.15 4945.98 4946.11 4946.23 4946.48 4946.61 4946.73 4946.98 4947.11 4947.23 4947.48 4947.61 4947.72 4947.40 4947.13 4947.20 4947.68 4947.90 4948.03 4948.28 PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50 0.50% 0.50% -1.08% 2.20% -2.20% 1.08% PVI STA = 10+00.00 PVI ELEV = 4945.86 PVI STA = 14+43.95 PVI ELEV = 4947.28 PVI STA = 14+46.95 PVI ELEV = 4947.21 PVI STA = 14+50.00 PVI ELEV = 4947.33 PVI STA = 14+63.78 PVI ELEV = 4947.63 PVI STA = 14+77.62 PVI ELEV = 4947.32 PVI STA = 14+80.62 PVI ELEV = 4947.21 PVI STA = 14+83.62 PVI ELEV = 4947.28 50.0' VC HP ELEV = 4947.74 HP STA = 13+84.71 PVI STA = 13+93.95 PVI ELEV = 4947.82 BVCS: 13+68.95 BVCE: 4947.70 EVCS: 14+18.95 EVCE: 4947.55 A.D. = 1.58 K = 31.60 50.0' VC PVI STA = 15+33.62 PVI ELEV = 4947.82 BVCS: 15+08.62 BVCE: 4947.55 EVCS: 15+58.62 EVCE: 4947.95 A.D. = 0.58 K = 86.09 4945.86 4945.98 4946.11 4946.23 4946.36 4946.48 4946.61 4946.73 4946.86 4946.98 4947.11 4947.23 4947.36 4947.48 4947.61 4947.72 4947.70 4947.49 4947.33 4947.38 4947.46 4947.71 4947.90 4948.03 4948.15 4948.28 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH LINE MATCH STA 16+50 CENTERLINE DANCING CATTAIL DR SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP B B B2 R4 PLAN AND PROFILE DANCING CATTAIL DR 37 MATCH LINE SEE SHEET R5 STA 16+50 LEFT FLOWLINE DANCING CATTAIL DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE DANCING CATTAIL DR SCALE : 1" = 40' (H) 1" = 5' (V) G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E G G G G VAULT VAULT E E VAULT "STOP" SIGN w/ STREET NAMES 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK STA. = 27+57.92 (MISTY MEADOW DRIVE) STA. = 20+55.15 (ZEPHYR RD) WINDY WILLOW DR SEE SHEET R5 PROPOSED DRIVE OVER CURB AND GUTTER LOT 2 LOT 1 BLOCK 1 BLOCK 5 ∆ ∆ STORM DRAIN 1 SEE SHEET ST1 75.00 CROWN TRANSITION 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 23+00 24+00 25+00 26+00 27+00 28+00 29+00 EXISTING GROUND PROPOSED GRADE 4962.45 4960.45 4958.45 4956.45 4963.95 4963.45 4962.95 4961.95 4961.45 4960.95 4959.95 4959.45 4958.95 4957.95 4957.45 4956.95 4955.95 4956.28 PROPOSED GRADE EXISTING GROUND PVI STA = 27+24.87 PVI ELEV = 4955.96 PVI STA = 27+28.87 PVI ELEV = 4955.86 PVI STA = 27+32.88 PVI ELEV = 4955.96 PVI STA = 27+57.92 PVI ELEV = 4956.42 1.86% -2.00% 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 23+00 24+00 25+00 26+00 27+00 28+00 29+00 PVI STA = 27+19.71 PVI ELEV = 4956.29 50.5' VC PVI STA = 26+88.29 PVI ELEV = 4956.46 BCVS: 26+63.06 BVCE: 4956.95 ECVS: 27+13.52 EVCE: 4956.32 A.D. = 1.45 K = 34.85 4963.64 4963.14 4962.65 4962.15 4961.66 4961.16 4960.67 4960.18 4959.68 4959.19 4958.69 4958.20 4957.71 4957.21 4956.74 4956.42 PROPOSED GRADE EXISTING GROUND -0.53% -1.98% 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 23+00 24+00 25+00 26+00 27+00 28+00 29+00 PVI STA = 26+80.06 PVI ELEV = 4956.25 PVI STA = 27+05.06 PVI ELEV = 4955.79 4963.43 4962.93 4962.42 4961.92 4961.41 4960.91 4960.40 4959.90 4959.39 4958.88 4958.38 4957.87 4957.37 4956.86 4956.36 4955.88 PROPOSED GRADE EXISTING GROUND -1.87% -2.02% NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 LINE MATCH STA 23+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP A A R3 PLAN AND PROFILE MISTY MEADOW DR 36 A CENTERLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R2 STA 23+00 G G G G G G G G G E E E E E E E E G G G G G E E E E E E E E E G G G G G G G G VAULT VAULT VAULT VAULT VAULT E E E E E E E E E 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 5' TRAIL CROAKING TOAD DR SEE SHEET R7 ALLEY 1 ALLEY 2 77.00 CROWN TRANSITION 78.00 CROWN TRANSITION 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 15+75 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 EXISTING GROUND PROPOSED GRADE 4969.46 4967.23 4965.23 4964.02 4965.02 4965.52 4965.95 4968.80 4968.23 4967.73 4966.73 4966.23 4965.73 4964.73 4964.23 4963.73 4964.48 4964.76 4964.89 4965.14 4965.27 4965.39 4965.64 4965.77 4965.89 4965.80 4965.45 4964.95 PROPOSED GRADE EXISTING GROUND PVI STA = 18+77.20 PVI ELEV = 4963.68 PVI STA = 18+80.20 PVI ELEV = 4963.61 PVI STA = 18+83.20 PVI ELEV = 4963.68 50.0' VC PVI STA = 19+33.20 PVI ELEV = 4964.68 BVCS: 19+08.20 BVCE: 4964.18 EVCS: 19+58.20 EVCE: 4964.81 A.D. = 1.50 K = 33.33 76.4' VC HP ELEV = 4965.95 HP STA = 21+94.62 PVI STA = 22+17.54 PVI ELEV = 4966.10 BVCS: 21+79.34 BVCE: 4965.91 EVCS: 22+55.74 EVCE: 4965.34 A.D. = 2.50 K = 30.56 75.0' VC PVI STA = 16+21.26 PVI ELEV = 4968.80 BCVS: 15+83.76 BVCE: 4969.93 ECVS: 16+58.76 EVCE: 4968.05 A.D. = 1.00 K = 75.00 -2.00% 2.00% 0.50% -2.00% 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 15+75 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 4969.14 4966.88 4964.88 4963.87 4964.58 4965.08 4965.53 4968.48 4967.89 4967.38 4966.38 4965.88 4965.38 4964.41 4964.06 4963.84 4964.06 4964.28 4964.45 4964.70 4964.83 4964.95 4965.20 4965.33 4965.45 4965.42 4965.10 4964.62 PVI STA = 18+83.95 PVI ELEV = 4963.79 PVI STA = 19+08.95 PVI ELEV = 4963.91 PVI STA = 19+61.95 PVI ELEV = 4964.39 75.0' VC PVI STA = 16+25.01 PVI ELEV = 4968.38 BCVS: 15+87.51 BVCE: 4969.51 ECVS: 16+62.51 EVCE: 4967.63 A.D. = 1.00 K = 75.10 75.1' VC PVI STA = 18+44.89 PVI ELEV = 4963.98 BCVS: 18+07.34 BVCE: 4964.73 ECVS: 18+82.44 EVCE: 4963.79 A.D. = 1.50 K = 50.02 PROPOSED GRADE EXISTING GROUND 76.4' VC HP ELEV = 4965.53 HP STA = 21+98.52 PVI STA = 22+21.29 PVI ELEV = 4965.68 BVCS: 21+83.09 BVCE: 4965.49 EVCS: 22+59.49 EVCE: 4964.93 A.D. = 2.48 K = 30.85 EXISTING GROUND PROPOSED GRADE -1.98% -2.00% 0.50% -0.50% 0.50% 0.90% 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 15+75 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 STREET A Right Flowline 4966.84 4966.59 4966.77 4966.88 4966.98 4967.59 4967.95 4966.69 4966.60 4966.59 4966.63 4966.63 4966.67 4967.01 4966.78 4966.76 4966.79 4967.19 4967.38 4967.50 4967.62 4967.67 4967.75 4968.22 4968.32 4968.39 PVI STA = 18+73.45 PVI ELEV = 4963.50 PVI STA = 18+76.45 PVI ELEV = 4963.43 PVI STA = 18+79.45 PVI ELEV = 4963.50 50.0' VC PVI STA = 19+29.45 PVI ELEV = 4964.26 BVCS: 19+04.45 BVCE: 4963.88 EVCS: 19+54.45 EVCE: 4964.39 A.D. = 1.02 K = 49.01 75.7' VC HP ELEV = 4965.53 HP STA = 21+90.86 PVI STA = 22+13.71 PVI ELEV = 4965.68 BVCS: 21+75.84 BVCE: 4965.49 EVCS: 22+51.57 EVCE: 4964.92 A.D. = 2.52 K = 30.03 75.0' VC PVI STA = 16+17.51 PVI ELEV = 4968.38 BCVS: 15+80.01 BVCE: 4969.51 ECVS: 16+55.01 EVCE: 4967.63 A.D. = 1.00 K = 75.00 75.0' VC PVI STA = 18+35.95 PVI ELEV = 4964.01 BCVS: 17+98.44 BVCE: 4964.76 ECVS: 18+73.45 EVCE: 4963.50 A.D. = 0.64 K = 117.29 PROPOSED GRADE EXISTING GROUND 1.52% 0.50% -1.36% -2.00% -2.02% NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 LINE MATCH STA 15+75 LINE MATCH STA 23+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP A A R2 PLAN AND PROFILE MISTY MEADOW DR 35 A CENTERLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R1 STA 15+75 MATCH LINE SEE SHEET R3 STA 23+00 A.D. = 1.50 K = 51.50 2.00% -3.00% 0.50% ∆ 53' ROW 30' FL-FL MISTY MEADOW DR MISTY MEADOW DR LOT 1 LOT 8 LOT 6 LOT 7 LOT 12 LOT 17 LOT 16 LOT 15 LOT 14 LOT 13 LOT 10 LOT 11 LOT 9 LOT 16 LOT 15 LOT 13 LOT 14 LOT 12 LOT 11 LOT 9 LOT 10 LOT 8 LOT 7 LOT 5 LOT 4 LOT 6 PROPOSED DRIVE OVER CURB AND GUTTER BLOCK 10 BLOCK 11 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E G G G G G UD UD UD UD UD UD UD UD UD UD V AULT E VAULT VAULT E E E E STA. = 14+96.68 (MISTY MEADOW DRIVE) STA. = 10+00.00 (FALLEN BRANCH DR) FALLEN BRANCH DR SEE SHEET R9 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT ∆ ∆ STORM DRAIN 7 SEE SHEET ST5 SUBDRAIN 1 SEE SHEET SD1 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 9+50 10+00 11+00 12+00 13+00 14+00 15+00 15+75 STREET A Left Flowline 4965.64 4965.76 4965.89 4966.01 4966.14 4966.26 4966.39 4966.51 4966.63 4966.76 4966.94 4967.23 4967.65 4968.14 4968.64 4969.13 4969.63 4970.13 4970.62 4971.06 4971.22 4971.07 4970.60 100.4' VC HP ELEV = 4971.22 HP STA = 15+00.16 PVI STA = 15+10.37 PVI ELEV = 4971.82 BVCS: 14+60.17 BVCE: 4970.82 EVCS: 15+60.57 EVCE: 4970.32 A.D. = 4.99 K = 20.14 79.5' VC PVI STA = 12+65.53 PVI ELEV = 4966.96 BCVS: 12+25.78 BVCE: 4966.76 ECVS: 13+05.28 EVCE: 4967.75 A.D. = 1.49 K = 53.38 PROPOSED GRADE EXISTING GROUND PVI STA = 10+00.00 PVI ELEV = 4965.64 -3.00% 0.50% 1.99% 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 9+50 10+00 11+00 12+00 13+STREET 00 14+00 A Right 15+00 Flowline 15+75 100.4' VC HP ELEV = 4971.22 HP STA = 14+93.01 PVI STA = 15+02.84 PVI ELEV = 4971.82 BVCS: 14+52.66 BVCE: 4970.81 EVCS: 15+53.01 EVCE: 4970.32 A.D. = 5.02 K = 20.00 75.0' VC PVI STA = 12+61.78 PVI ELEV = 4966.96 BCVS: 12+24.28 BVCE: 4966.77 ECVS: 12+99.28 EVCE: 4967.72 A.D. = 1.51 K = 49.54 4965.64 4965.77 4965.89 4966.02 4966.14 4966.27 4966.40 4966.52 4966.65 4966.77 4966.97 4967.28 4967.73 4968.23 4968.74 4969.24 4969.75 4970.25 4970.76 4971.14 4971.20 4970.96 4970.40 PROPOSED GRADE EXISTING GROUND PVI STA = 10+00.00 PVI ELEV = 4965.64 0.50% 2.02% -3.00% CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH LINE MATCH STA 15+75 CENTERLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING, SYMBOLS, AND SIGNS THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. THE DEVELOPER SHALL PLACE TEMPORARY TABS, TAPE OR FLAGS DEPICTING ALIGNMENT AND LOCATION. CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS AT 970-221-6630 FOR FIELD REVIEW. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP A A A R1 PLAN AND PROFILE MISTY MEADOW DR 34 LEFT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R2 STA 15+75 60.69 59.86 54.08 58.88 58.07 53.04 53.24 57.26 56.47 53.44 54.36 54.48 54.93 55.65 58.98 STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 52.85 50.98 51.08 51.17 52.27 53.46 58.52 58.52 60.09 60.46 59.68 58.34 56.34 55.22 52.35 52.46 52.51 52.92 55.05 50.33 48.37 48.80 48.95 47.85 8.00' UTILITY EASEMENT 19.50' EOC-FL B FG=56.24 TF=56.91 LOT 6 15.5% 19.1% 19.5% B FG=58.06 TF=58.73 LOT 1 B FG=58.87 TF=59.54 LOT 2 B FG=59.69 TF=60.36 LOT 3 B FG=59.69 TF=60.36 LOT 4 B FG=62.81 TF=63.48 LOT 1 B FG=61.96 TF=62.63 LOT 2 B FG=60.24 TF=60.91 LOT 3 B FG=55.12 TF=55.79 LOT 4 B FG=54.40 TF=55.07 LOT 5 T FG=53.95 TF=54.62 LOT 6 A FG=53.64 TF=54.31 LOT 7 B FG=54.55 TF=55.22 LOT 1 53.90 59.64 61.46 59.19 58.37 57.56 53.14 53.45 53.22 19.5' EOC-FL 5.3% 5.3% 56.74 0.5% 0.5% 1' RIBBON CURB VERTICAL CURB AND GUTTER STORM DRAIN 1 SEE SHEET ST1 0.5% 0.5% 18.50' EMERGENCY SPILLWAY 52.85 53.02 52.98 53.49 2.0% 2.0% 1.4% 0.0% 0.5% 0.5% 0.5% 53.20 54.96 54.82 52.80 54.52 19.1% 18.0% 19.6% 17.4% 1.9% 2.0% 2.1% 2.0% 2.1% 2.0% 1.5% 54.62 53.02 LINE TABLE LINE L1 L3 L5 L6 L9 L10 L12 L13 L41 L44 L45 L48 L49 LENGTH 61.99' 94.84' 35.65' 144.68' 35.23' 92.22' 140.36' 100.62' 53.34' 25.54' 104.27' 7.93' 11.64' BEARING S89°59'59.83"E N00°00'00.17"E N54°10'59.68"E N27°18'59.29"W N54°10'59.68"E N27°18'59.29"W S00°00'00.17"W N89°59'59.83"W N00°35'28.18"W N54°10'59.68"E S27°18'59.29"E S39°03'38.95"W S85°29'48.73"W CURVE TABLE CURVE C1 C2 C3 C4 C5 C17 C18 C19 DELTA 90°00'00" 54°11'00" 67°23'40" 14°06'19" 152°41'01" 40°40'09" 14°06'19" 24°43'10" RADIUS 20.00' 164.50' 20.00' 144.50' 20.50' 30.00' 154.50' 266.54' LENGTH 31.42' 155.56' 23.53' 35.57' 54.63' 21.29' 38.04' 115.00' BEARING N45°00'00"E N27°05'30"E N06°22'51"E N47°07'50"E S76°20'30"W N19°44'36"E N47°07'50"E S24°59'46"W CHORD 28.28' 149.83' 22.19' 35.48' 39.84' 20.85' 37.94' 114.11' B M KEYMAP G8 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G8 DETAILED GRADING PLAN 33 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES BLOCK 3 TRACT K DUA&EAE 5' TRAIL 5' TRAIL ZEPHYR RD ROSEN DRIVE PROPOSED STORM DRAIN 57.26 56.47 53.44 54.83 54.59 54.36 54.48 54.93 55.48 56.17 58.14 59.37 62.02 62.96 63.74 64.71 65.58 66.42 67.13 67.71 68.28 68.70 55.81 56.48 56.17 55.63 54.79 54.57 54.38 54.77 55.28 55.76 56.22 56.70 57.18 57.66 58.14 58.74 59.49 60.24 60.99 61.74 62.49 63.24 63.99 64.66 60.40 59.95 61.23 60.75 61.05 61.91 62.60 63.42 63.79 61.71 61.62 61.53 58.84 59.29 59.97 58.79 58.92 59.04 59.17 58.59 58.47 58.32 58.14 58.07 57.75 57.64 57.54 57.44 57.32 57.19 57.09 56.38 56.81 57.23 57.65 58.07 58.41 58.40 57.29 57.08 59.16 58.96 56.88 56.68 59.36 59.35 57.49 56.50 58.27 55.65 56.92 57.41 STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 B FG=56.24 TF=56.91 LOT 6 A FG=67.41 TF=68.08 LOT 22 A FG=67.41 TF=68.08 LOT 21 A FG=65.91 TF=66.58 LOT 20 A FG=65.91 TF=66.58 LOT 19 A FG=64.74 TF=65.41 LOT 18 A FG=64.74 TF=65.41 LOT 17 A FG=62.91 TF=63.58 LOT 16 A FG=62.91 TF=63.58 LOT 15 A FG=61.41 TF=62.08 LOT 14 A FG=61.41 TF=62.08 LOT 13 T FG=60.33 TF=61.00 LOT 12 T FG=60.33 TF=61.00 LOT 11 B FG=58.95 TF=59.62 LOT 10 B FG=58.95 TF=59.62 LOT 9 B FG=57.39 TF=58.06 LOT 8 B FG=57.39 TF=58.06 LOT 7 B FG=56.24 TF=56.91 LOT 5 B FG=57.12 TF=57.79 LOT 4 B FG=57.12 TF=57.79 LOT 3 B FG=57.63 TF=58.30 LOT 2 B FG=57.63 TF=58.30 LOT 1 B FG=58.30 TF=58.97 LOT 1 B FG=58.30 TF=58.97 LOT 2 B FG=58.83 TF=59.50 LOT 3 B FG=58.83 TF=59.50 LOT 4 B FG=58.83 TF=59.50 LOT 5 B FG=58.83 TF=59.50 LOT 6 B FG=59.88 TF=60.55 LOT 1 B FG=59.88 TF=60.55 LOT 2 B FG=60.30 TF=60.97 LOT 3 B FG=60.30 TF=60.97 LOT 4 B FG=59.69 TF=60.36 LOT 10 B FG=59.69 TF=60.36 LOT 9 B FG=59.69 TF=60.36 LOT 8 B FG=59.69 TF=60.36 LOT 7 B FG=62.15 TF=62.82 LOT 10 B FG=62.15 TF=62.82 LOT 9 B FG=63.40 TF=64.07 LOT 8 B FG=63.40 TF=64.07 LOT 7 B FG=64.49 TF=65.16 LOT 6 B FG=64.49 TF=65.16 LOT 5 TRACT L DU&PAE B FG=58.06 TF=58.73 LOT 1 B FG=58.87 TF=59.54 LOT 2 57.56 59.13 56.89 58.45 60.91 62.41 64.24 65.41 66.91 62.90 61.65 58.33 57.80 59.38 56.62 55.74 59.83 24' FL-FL 18.58' FL-EOC 1' RIBBON CURB 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 2' CONCRETE PAN 20' PROPOSED DRIVE-OVER CURB AND GUTTER 2.0% 1.7% 55.10 58.53 59.08 0.8% 1.3% 3.0% 2.0% 2.0% 1.5% 1.5% 57.09 57.15 57.26 57.32 54.96 55.20 56.11 57.59 58.71 58.73 59.42 58.23 58.69 57.73 64.56 60.16 60.91 61.66 62.41 63.16 63.91 58.15 57.33 57.15 57.22 57.34 58.06 57.71 57.71 0.4% 0.4% 0.4% 0.1% 0.6% 1.9% 0.8% 57.55 2.2% 2.2% 2.6% 2.2% 0.6% 0.8% 0.8% 0.8% 0.8% 64.46 57.37 54.73 55.26 57.04 56.94 57.03 20.00' EOC-FL 20.00' EOC-EOC 24.00' FL-FL 18.58' FL-EOC 56.24 56.27 56.42 56.39 53.20 54.96 54.82 52.80 54.52 54.43 5.5% 19.1% 18.0% 19.6% 17.4% 3.6% 3.2% 3.7% 4.4% 2.0% 4.4% 25.1% 25.1% 59.78 60.52 61.27 62.02 62.77 63.52 64.27 2.0% 2.3% 2.1% 2.0% 1.5% 1.5% 2.2% 1.8% 1.3% 2.2% 1.1% 2.2% 2.3% 2.2% 2.3% 2.2% 2.2% 2.0% 2.0% 2.0% 2.0% 56.83 58.88 57.60 54.97 56.29 2.0% 2.0% 5' SIDEWALK 4' SIDEWALK 4' SIDEWALK 63.99 57.07 60.63 2.0% 1.5% 54.62 53.31 54.55 LINE TABLE LINE L14 L19 L20 L22 L23 L26 L27 L29 L30 L31 L32 L33 L34 L35 L39 LENGTH 194.24' 150.43' 153.58' 59.00' 214.49' 91.53' 192.78' 171.17' 97.12' 9.19' 11.38' 173.58' 256.42' 237.03' 120.03' BEARING N00°01'01.94"E S89°58'58.06"E N89°58'58.06"W S00°01'01.94"W S89°43'21.16"W S00°01'01.94"W N00°01'02.90"E N89°43'21.16"E N89°58'58.06"W S45°01'01.94"W N89°58'58.06"W S89°58'58.06"E N00°01'01.94"E S89°43'21.16"W S00°01'01.94"W CURVE TABLE CURVE C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 DELTA 105°26'27" 39°22'44" 14°43'33" 110°27'16" 90°00'00" 54°31'30" 35°10'49" 89°42'17" 14°47'56" 39°43'34" 35°10'49" RADIUS 30.00' 218.00' 65.00' 15.00' 15.00' 236.58' 83.58' 30.00' 125.00' 228.00' 75.00' LENGTH 55.21' 149.83' 16.71' 28.92' 23.56' 225.14' 51.32' 46.97' 32.29' 158.08' 46.05' BEARING N52°42'11"W S54°53'13"W S27°50'05"W S34°45'20"E S45°01'02"W S62°27'36"W S17°36'26"W N44°52'12"E S82°19'23"W S55°03'38"W S17°36'26"W CHORD 47.74' 146.90' 16.66' 24.64' 21.21' 216.74' 50.52' 42.32' 32.20' 154.94' 45.33' Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G7 DETAILED GRADING PLAN 32 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH B M KEYMAP LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES G7 E E E E E E E E E E E E E 12" W 12" W 12" W 12" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV G FO G X X SS SS SS ST T ELEC ELEC VAULT ELEC ELEC B M X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 8" W 8" W IRR IRR IRR IRR IRR T S T S T S T S E E E E E E E E E E 15' EASEMENT REC. NO. 20140004033 PLANNED HANSEN FARM TRACT N DU&PAE LOT 3 LOT 4 LOT 8 LOT 7 LOT 6 LOT 5 BLOCK 3 BLOCK 3 ZEPHYR RD ROSEN DRIVE ZEPHYR RD (PLANNED) TIMBERLINE ROAD PROPOSED STORM DRAIN EXISTING TOP OF DITCH BANK 64.71 65.58 66.42 67.13 67.77 68.28 68.70 60.63 61.38 62.13 62.88 63.63 64.38 65.13 61.23 60.75 61.05 61.91 62.60 63.42 63.79 61.71 61.62 61.53 58.92 59.04 59.17 58.59 58.47 58.32 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 LOT 22 A FG=64.74 TF=65.41 A FG=65.91 TF=66.58 A FG=67.41 TF=68.08 B FG=63.40 TF=64.07 B FG=64.49 TF=65.16 59.38 B FG=60.30 TF=60.97 61.65 62.90 64.24 65.41 66.91 59.80 63.99 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G6 GRADING PLAN 31 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH B M KEYMAP LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES MATCHLINE-SEE SHEET G5 G1 G2 G3 G4 G5 G6 G G G G G G G G G G G G T T T T T T T T T ST W W W W W W W W W W W W W W W V AULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT 6' UTILITY EASEMENT 53' ROW 57' ROW 76' ROW 54' FL-FL 30' FL-FL 20' 20' 15' EASEMENT REC. NO. 20140004033 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 20' 20' 6' UTILITY EASEMENT BLOCK 1 BLOCK 1 BLOCK 13 BLOCK 14 BLOCK 14 BLOCK 15 BLOCK 16 BLOCK 5 BLOCK 4 TRACT T DUE TRACT J TRACT F TRACT Q TRACT I TRACT H TRACT G DETENTION POND 1 DITCH LATERAL TRACT D DUA&EAE TRACT S DUA 5' TRAIL 5' TRAIL 5' TRAIL 5' TRAIL 5' TRAIL 5' TRAIL TRACT M TRACT E DGE TRACT N DU&PAE 36' FL-FL 30' FL-FL 53' ROW 57' ROW 36' FL-FL 5' TRAIL LOT 1 LOT 2 LOT 3 LOT 4 LOT 10 LOT 9 LOT 8 LOT 7 LOT 10 LOT 9 LOT 7 LOT 1 LOT 8 LOT 47 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 BLOCK 2 BLOCK 3 BLOCK 3 TRACT K DUA&EAE 5' TRAIL 5' TRAIL 5' UTILITY EASEMENT FLYING MALLARD DR WINDY WILLOW DR MISTY MEADOW DR ZEPHYR RD DANCING CATTAIL DR ROSEN DRIVE RED WILLOW DRIVE BLOCK 6 18.4% 25.6% 24.3% 27.2% 2.5% 6.1% 5.1% 5.7% EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK ALLEY 66.04 65.28 64.29 66.39 60.82 58.81 57.94 55.86 56.80 54.79 53.77 51.69 50.54 51.56 52.71 49.68 48.49 48.00 47.75 47.56 47.53 47.73 47.95 48.17 48.39 48.57 48.78 49.06 49.61 49.97 48.49 48.27 50.20 48.05 50.40 50.60 47.83 47.62 50.80 50.92 47.67 47.92 51.16 51.71 48.25 49.34 52.59 51.44 53.21 55.69 56.67 54.87 53.81 58.80 58.11 60.52 62.93 65.03 64.17 62.75 60.96 48.00 48.50 48.75 48.25 48.50 49.00 49.25 51.36 51.83 49.40 49.65 55.13 54.90 49.90 50.15 55.23 54.58 50.37 50.53 53.67 53.35 50.69 49.49 49.70 50.01 50.35 49.77 49.99 50.40 50.89 51.07 50.46 50.66 51.27 50.86 51.51 51.20 52.03 52.83 51.76 52.43 53.87 55.17 53.93 56.36 56.63 58.41 59.08 61.76 60.08 61.59 63.71 65.05 63.89 62.73 65.81 66.10 65.03 64.22 63.61 61.66 62.73 60.25 59.69 57.32 57.70 55.70 54.84 53.16 54.04 52.73 51.82 51.09 52.07 51.59 50.83 50.61 51.10 50.75 50.41 50.21 50.55 53.35 50.79 51.22 53.38 51.42 51.88 53.18 52.91 53.25 54.89 54.42 55.07 56.46 59.34 56.26 58.03 61.16 62.31 62.11 60.69 59.86 54.08 58.88 58.07 53.04 53.24 57.26 56.47 53.44 55.46 55.08 54.83 54.59 54.36 54.48 54.93 55.48 56.17 57.07 58.14 59.37 60.63 62.02 62.96 63.83 64.71 65.58 55.81 56.48 56.57 56.02 55.48 55.19 54.97 54.73 55.17 55.67 56.13 56.60 57.09 57.59 58.06 58.54 59.13 59.88 60.63 61.38 62.13 60.40 59.95 61.23 60.75 61.05 61.91 58.84 59.29 59.97 58.79 58.92 59.04 58.47 58.32 58.14 58.07 57.75 57.64 57.54 57.44 57.32 57.19 57.09 56.38 56.81 57.23 57.65 58.07 58.41 58.40 57.29 57.08 59.16 59.05 56.88 56.68 59.36 59.35 57.49 56.50 58.27 55.65 56.92 57.41 62.54 55.63 55.08 58.98 62.67 STORM DRAIN 2 SEE SHEET ST2 STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 48.77 48.55 48.33 48.11 48.13 48.38 48.87 50.07 55.18 57.19 59.22 61.26 63.66 61.57 59.27 57.07 52.99 52.11 51.57 51.00 50.80 50.60 50.37 51.00 51.20 51.40 51.68 52.03 52.42 53.12 58.33 60.80 63.01 64.74 65.23 63.17 61.63 54.20 53.15 52.44 52.00 51.78 51.58 53.22 53.90 59.64 61.46 53.07 52.30 52.33 52.05 51.80 A FG=68.44 TF=69.11 A FG=67.73 TF=68.40 LOT 15 PROPOSED 12' CURB CUT B FG=50.35 TF=51.02 LOT 10 B FG=50.30 TF=50.97 LOT 9 B FG=51.58 TF=52.25 LOT 8 A FG=52.30 TF=52.97 LOT 7 A FG=52.55 TF=53.22 LOT 6 A FG=52.83 TF=53.50 LOT 5 A FG=52.80 TF=53.47 LOT 4 A FG=53.57 TF=54.24 LOT 3 T FG=54.24 TF=54.91 LOT 2 B FG=54.55 TF=55.22 LOT 1 A FG=53.64 TF=54.31 LOT 7 T FG=53.95 TF=54.62 LOT 6 B FG=54.40 TF=55.07 LOT 5 T FG=55.12 TF=55.79 LOT 4 STORM DRAIN 1 SEE SHEET ST1 T FG=60.24 TF=60.91 LOT 3 B FG=61.96 TF=62.63 LOT 2 B FG=62.81 TF=63.48 LOT 1 B FG=52.08 TF=52.75 LOT 1 B FG=52.28 TF=52.95 LOT 2 B FG=52.50 TF=53.17 LOT 3 B FG=52.94 TF=53.61 LOT 4 B FG=53.65 TF=54.32 LOT 5 B FG=52.53 TF=53.20 LOT 9 B FG=54.70 TF=55.37 LOT 6 T FG=56.01 TF=56.68 LOT 7 T FG=60.08 TF=60.75 LOT 8 T FG=62.13 TF=62.80 LOT 9 A FG=63.67 TF=64.34 LOT 10 A FG=65.73 TF=66.40 LOT 11 B FG=66.67 TF=67.34 LOT 1 B FG=65.24 TF=65.91 LOT 2 B FG=63.51 TF=64.18 LOT 3 B FG=61.30 TF=61.97 LOT 4 T FG=58.83 TF=59.50 LOT 5 T FG=54.97 TF=55.64 LOT 6 B FG=53.62 TF=54.29 LOT 7 B FG=52.92 TF=53.59 LOT 8 B FG=52.18 TF=52.85 LOT 10 B FG=51.90 TF=52.57 LOT 11 B FG=51.70 TF=52.37 LOT 12 B FG=51.50 TF=52.17 LOT 13 B FG=50.87 TF=51.54 LOT 1 B FG=51.10 TF=51.77 LOT 2 B FG=51.30 TF=51.97 LOT 3 B FG=51.50 TF=52.17 LOT 4 B FG=51.50 TF=52.17 LOT 5 B FG=52.07 TF=52.74 LOT 6 B FG=52.61 TF=53.28 LOT 7 B FG=53.49 TF=54.16 LOT 8 T FG=49.71 TF=50.38 LOT 9 T FG=57.57 TF=58.24 LOT 10 B FG=59.77 TF=60.44 LOT 11 B FG=62.07 TF=62.74 LOT 12 B FG=64.16 TF=64.83 LOT 13 B FG=65.69 TF=66.36 LOT 14 TF=66.80 B FG=61.76 TF=62.43 LOT 4 B FG=59.72 TF=60.39 LOT 5 B FG=57.69 TF=58.36 LOT 6 T FG=55.68 TF=56.35 LOT 7 T FG=52.49 TF=53.16 LOT 8 B FG=50.57 TF=51.24 LOT 9 B FG=49.37 TF=50.04 LOT 10 FG=48.88 TF=49.55 LOT 11 47.07 B FG=57.63 TF=58.30 LOT 16 LOT 17 LOT 18 LOT 3 LOT 14 LOT 15 LOT 12 LOT 13 LOT 10 LOT 11 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 1 LOT 2 B FG=57.12 TF=57.79 B FG=56.24 TF=56.91 B FG=57.39 TF=58.06 B FG=58.95 TF=59.62 T FG=60.33 TF=61.00 A FG=61.41 TF=62.08 A FG=62.91 TF=63.58 A FG=64.74 TF=65.41 B FG=59.69 TF=60.36 B FG=59.69 TF=60.36 B FG=62.15 TF=62.82 B FG=63.40 TF=64.07 59.38 B FG=60.30 TF=60.97 B FG=59.88 TF=60.55 57.80 58.33 B FG=58.83 TF=59.50 B FG=58.83 TF=59.50 B FG=58.30 TF=58.97 59.28 61.65 60.91 62.41 64.24 B FG=58.06 TF=58.73 LOT 1 B FG=58.87 TF=59.54 LOT 2 B FG=59.69 TF=60.36 LOT 3 B FG=59.69 TF=60.36 LOT 4 53.14 53.45 59.19 58.37 57.56 53.46 53.02 52.27 56.62 55.74 56.89 58.45 52.71 49.80 49.55 59.58 70.13 70.13 1.3% ALLEY 1 ALLEY 2 0.5% 0.5% 49.02 48.99 48.97 48.71 48.17 47.95 48.37 48.35 63.46 69.65 60.26 58.54 56.54 55.05 5.3% 5.3% 5.3% 56.83 55.78 54.62 55.51 54.47 66.07 53.45 51.99 61.72 53.64 PROPOSED CURB CUT & SIDEWALK CULVERT (SEE DTL 402 SHEET D4) PROPOSED CURB CUT & SIDEWALK CULVERT (SEE DTL 402 SHEET D4) 52.73 59.83 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G5 GRADING PLAN 30 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH B M KEYMAP LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES MATCHLINE-SEE SHEET G3 MATCHLINE-SEE SHEET G4 MATCHLINE-SEE SHEET G6 G1 G2 G3 G4 G5 G6 30' FL-FL 30' FL-FL 30' EASEMENT REC. NO. 20140004033 15' EASEMENT REC. NO. 20110070565 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 20' 15' UTILITY EASEMENT REC. NO. 20110070565 30' UTILITY EASEMENT REC. NO. 20100004033 UD UD UD UD UD UD UD UD UD BLOCK 12 BLOCK 12 DITCH LATERAL PLANNED HANSEN FARM 5' TRAIL TRACT U D&PAE 6' UTILITY EASEMENT 5' UTILITY EASEMENT MISTY MEADOW DR CROAKING TOAD DR PROPOSED PEDESTRIAN BRIDGE EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK NATURAL HABITAT BUFFER ZONE 73.46 72.30 68.67 70.86 70.07 67.64 66.64 69.07 68.07 65.64 67.20 64.77 67.19 66.19 57.41 57.22 58.03 65.20 61.35 66.85 64.42 64.81 67.23 67.56 65.14 65.39 67.81 68.06 65.64 65.89 67.99 68.46 66.04 66.04 68.47 67.71 66.39 65.18 64.46 63.08 63.81 64.85 63.62 64.42 57.13 61.89 62.82 60.82 60.03 57.94 55.86 60.52 62.93 64.56 65.38 65.67 65.03 64.17 65.03 67.23 67.94 68.32 68.04 67.79 67.54 67.25 66.89 66.88 67.52 68.52 69.52 70.55 72.93 67.00 59.22 61.26 63.21 64.38 65.19 63.66 W FG=68.50 TF=69.17 LOT 3 A FG=71.05 TF=71.72 LOT 3 A FG=70.02 TF=70.69 LOT 4 A FG=69.02 TF=69.69 LOT 5 A FG=68.02 TF=68.69 LOT 6 A FG=67.38 TF=68.05 LOT 7 A FG=67.39 TF=68.06 LOT 8 A FG=67.75 TF=68.42 LOT 9 A FG=68.04 TF=68.71 LOT 10 A FG=68.29 TF=68.96 LOT 11 A FG=68.54 TF=69.21 LOT 12 A FG=68.82 TF=69.49 LOT 13 A FG=68.44 TF=69.11 LOT 14 A FG=67.73 LOT 15 W FG=62.30 TF=62.97 LOT 13 LOT 13 B FG=65.69 TF=66.36 LOT 14 T FG=66.13 TF=66.80 LOT 15 B FG=66.03 TF=66.70 LOT 1 B FG=64.88 TF=65.55 LOT 2 B FG=63.71 TF=64.38 LOT 3 B FG=61.76 TF=62.43 LOT 4 B LOT 5 T FG=77.79 TF=78.46 LOT 2 T FG=77.79 TF=78.46 LOT 1 59.27 A FG=73.43 TF=74.10 LOT 2 65.99 70.13 71.00 70.13 70.13 70.13 67.79 65.52 65.11 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G4 GRADING PLAN 29 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH B M KEYMAP LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES MATCHLINE-SEE SHEET G5 MATCHLINE-SEE SHEET G2 G1 G2 G3 G4 G5 G6 PROPOSED 2' CONCRETE PAN PROPOSED FOREBAY 2 (SEE DETAIL SHEET D4) PROPOSED CURB CUT & SIDEWALK CULVERT (SEE DTL 401 SHEET D4) WETLAND BUFFER (TYP.) PROPOSED STORM DRAIN STUB FOR FUTURE DEVELOPMENT 23.0% 15.9% 22.8% 22.8% 24.9% 21.3% 12.5% 4.3% 7.7% GRASS-LINED SWALE NATURAL HABITAT BUFFER ZONE 47.00 52.86 55.00 53.77 51.69 50.54 48.71 47.54 47.04 47.75 46.81 46.58 47.56 47.53 46.54 46.75 47.73 47.95 46.95 47.15 48.17 47.35 48.39 47.53 48.03 48.57 47.00 50.64 45.31 48.74 47.54 45.00 45.00 47.03 45.00 46.77 46.06 45.00 46.10 45.00 48.90 46.79 47.05 49.16 50.25 47.30 47.53 48.01 48.14 48.26 48.69 48.90 48.60 48.30 48.00 47.71 46.80 49.38 49.11 46.55 45.00 45.97 45.00 44.92 45.00 45.17 45.34 45.28 45.00 45.64 45.94 45.00 45.00 46.20 46.45 45.00 45.00 46.69 46.94 45.00 45.00 47.19 47.44 45.00 45.00 47.69 47.94 45.00 45.00 48.19 48.33 46.49 48.34 48.12 47.94 47.40 47.42 47.96 47.28 47.02 46.46 48.11 47.94 48.35 48.00 48.50 45.00 45.00 45.50 45.99 STORM DRAIN 4 SEE SHEET ST3 STORM DRAIN 5 SEE SHEET ST4 STORM DRAIN 6 SEE SHEET ST4 55.81 STORM DRAIN 1 SEE SHEET ST1 49.15 48.34 47.83 47.58 48.56 49.20 48.95 48.78 48.77 48.55 48.33 48.11 48.13 48.38 48.87 W FG=56.31 TF=56.98 LOT 10 B FG=51.54 TF=52.21 LOT 9 B FG=49.65 TF=50.32 LOT 8 B FG=48.84 TF=49.51 LOT 7 B FG=48.33 TF=49.00 LOT 6 B FG=48.08 TF=48.75 LOT 5 PROPOSED 12' CURB T CUT FG=49.12 TF=49.79 LOT 4 A FG=49.70 TF=50.37 LOT 3 A FG=49.76 TF=50.43 LOT 2 A FG=49.98 TF=50.65 LOT 1 A FG=50.66 TF=51.33 LOT 10 B FG=50.55 TF=51.22 LOT 9 B FG=49.89 TF=50.56 LOT 8 B FG=49.89 TF=50.56 B LOT 7 FG=49.64 TF=50.31 LOT 6 B FG=49.40 TF=50.07 LOT 5 B FG=44.12 TF=44.79 LOT 4 A FG=49.28 TF=49.95 A LOT 3 FG=49.45 TF=50.12 LOT 2 A FG=49.37 TF=50.04 LOT 1 T FG=45.97 TF=46.64 LOT 14 B FG=46.94 TF=47.61 LOT 13 B FG=47.24 TF=47.91 LOT 12 B FG=47.50 TF=48.17 LOT 11 B FG=47.75 TF=48.42 LOT 10 B FG=47.99 TF=48.66 LOT 9 B FG=48.24 TF=48.91 LOT 8 B FG=48.49 TF=49.16 LOT 7 B FG=48.74 TF=49.41 LOT 6 B FG=48.99 TF=49.66 LOT 5 B FG=49.24 TF=49.91 LOT 4 B FG=49.49 TF=50.16 LOT 3 B FG=49.59 TF=50.26 LOT 2 B FG=49.59 TF=50.26 LOT 1 B FG=50.35 TF=51.02 LOT 11 B FG=50.35 TF=51.02 LOT 10 FG=55.68 TF=56.35 LOT 7 T FG=52.49 TF=53.16 LOT 8 B FG=50.57 TF=51.24 LOT 9 B FG=49.37 TF=50.04 LOT 10 B FG=48.88 TF=49.55 LOT 11 B FG=48.63 TF=49.30 LOT 12 B FG=48.61 TF=49.28 LOT 13 B FG=48.83 TF=49.50 LOT 14 B FG=49.05 TF=49.72 LOT 15 B FG=49.27 TF=49.94 LOT 16 B FG=49.27 TF=49.94 LOT 17 45.94 45.88 47.07 49.48 48.87 49.40 49.14 48.34 48.80 46.44 46.74 47.00 47.25 47.49 47.74 47.99 48.24 48.49 48.74 48.99 50.16 49.49 41.57 41.10 41.70 42.34 41.44 41.93 41.86 41.76 41.93 0.5% 0.5% 0.5% 44.00 44.00 1.0% 1.1% 1.0% 0.5% 0.5% 42.10 41.68 41.34 41.20 41.02 44.59 43.83 44.28 44.27 46.75 48.77 45.00 45.00 45.00 45.00 43.63 45.00 45.00 42.04 41.94 41.66 42.15 41.00 41.89 41.29 1.0% 0.5% 44.50 44.50 45.02 45.48 44.50 45.32 45.27 11' EMERGENCY SPILLWAY 43.70 43.70 47.56 1.3% 1.3% 42.21 46.50 46.65 3.1% 45.00 45.00 44.50 44.50 GRADE BREAK GRADE BREAK 44.70 45.00 45.00 45.45 50.05 47.41 PROPOSED FOREBAY 1 (SEE DETAIL SHEET D4) 41.46 41.54 42.00 2.5% 2.7% 2.9% 3.9% 1.9% 2.2% 2.1% 19' EMERGENCY SPILLWAY PROPOSED CURB CUT & SIDEWALK CULVERT (SEE DTL 401 SHEET D4) DETENTION POND DEPTH GAUGE B M KEYMAP Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G3 GRADING PLAN 28 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES MATCHLINE-SEE SHEET G2 MATCHLINE-SEE SHEET G5 G1 G2 G3 G4 G5 G6 UD UD UD UD UD UD UD UD UD UD UD V AULT VAULT VAULT VAULT 6' UTILITY EASEMENT 30' FL-FL 53' ROW 59' ROW 36' FL-FL 30' EASEMENT REC. NO. 20110070565 67' EASEMENT REC. NO. 20140004033 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT BLOCK 9 BLOCK 10 BLOCK 10 BLOCK 11 3.8% 7.3% 8.8% 6.6% 1.9% DETENTION POND TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT 5' TRAIL 5' TRAIL 5' TRAIL 6' UTILITY EASEMENT 6' UTILITY EASEMENT 5' UTILITY EASEMENT 5' UTILITY EASEMENT MISTY MEADOW DR FALLEN BRANCH DR RAIN GARDEN 1 MEDIA SQFT=5502 SQFT TOTAL VOLUME=12,246 CUFT BOT POND ELEV=4944.5 SPILLWAY ELEV=4946.0 5' TRAIL PROPERTY BOUNDARY (TYP.) EXISTING 36" IRON PIPE STORM WETLAND BUFFER (TYP.) GRADE BREAK 12.4% GRASS-LINED SWALE EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE 64.52 68.79 69.04 69.29 69.54 69.83 62.17 61.71 64.86 64.67 64.97 65.27 65.56 65.86 66.11 66.36 66.61 65.07 65.61 66.51 66.85 67.10 67.35 67.80 66.76 67.01 67.27 67.76 60.47 56.83 57.73 55.63 58.72 58.49 58.98 60.09 61.10 62.11 70.89 69.88 68.87 68.70 69.69 70.58 73.46 73.53 72.09 71.11 70.29 73.46 69.97 68.67 71.48 62.69 62.96 71.77 70.80 62.12 60.57 69.35 68.19 59.41 58.41 67.19 57.41 57.22 58.03 71.35 72.06 71.99 71.31 66.24 48.31 47.21 47.00 47.00 55.00 57.13 STORM DRAIN 7 SEE SHEET ST5 72.93 73.18 71.57 70.65 69.92 69.53 69.26 69.01 68.76 68.51 68.26 65.47 63.19 66.41 57.13 67.31 58.31 67.56 58.52 67.81 59.34 68.07 59.07 68.56 59.56 69.67 60.67 70.68 61.68 72.57 63.54 71.60 62.60 70.15 61.15 69.00 59.99 58.99 68.00 57.99 67.00 49.97 60.08 57.94 47.83 47.55 55.81 W FG=68.50 TF=69.17 LOT 3 W FG=69.49 TF=70.16 LOT 4 W FG=70.65 TF=71.32 LOT 5 W FG=72.10 TF=72.77 LOT 6 W FG=73.07 TF=73.74 LOT 7 T FG=73.04 TF=73.71 LOT 8 T FG=72.19 TF=72.86 LOT 9 W FG=71.18 TF=71.85 LOT 10 W FG=70.17 TF=70.84 LOT 11 W FG=69.06 TF=69.73 LOT 12 W FG=68.56 TF=69.23 LOT 13 W FG=68.31 TF=68.98 LOT 14 W FG=68.06 TF=68.73 LOT 15 W FG=67.81 TF=68.48 LOT 16 T FG=66.91 TF=67.58 LOT 17 G FG=65.97 TF=66.64 LOT 1 B FG=66.32 TF=66.99 LOT 2 T FG=67.75 TF=68.42 LOT 3 FG=68.40 TF=69.07 FG=68.61 TF=69.28 A FG=68.76 TF=69.43 LOT 6 A FG=69.01 TF=69.68 LOT 7 A FG=69.26 TF=69.93 LOT 8 A FG=69.51 TF=70.18 LOT 9 A FG=69.76 TF=70.43 LOT 10 A FG=70.03 TF=70.70 LOT 11 A FG=70.42 TF=71.09 LOT 12 A FG=71.15 TF=71.82 LOT 13 A FG=72.04 TF=72.71 LOT 14 W FG=62.30 TF=62.97 LOT 13 W FG=60.58 TF=61.25 LOT 12 W FG=58.54 TF=59.21 LOT 11 W FG=56.31 TF=56.98 LOT 10 A FG=74.35 TF=75.02 LOT 15 A FG=74.35 TF=75.02 LOT 16 FG=77.79 TF=78.46 LOT 2 59.27 60.61 56.65 A FG=73.43 TF=74.10 LOT 1 A FG=73.43 TF=74.10 LOT 2 STORM DRAIN 4 SEE SHEET ST3 STORM DRAIN 8 SEE SHEET ST5 2.6% 2.6% 2.6% 1.2% 1.2% 1.3% 1.3% 1.4% 1.0% 1.0% 1.2% 1.2% 55.32 52.83 51.45 48.74 47.68 46.80 46.03 45.20 44.43 44.28 56.97 46.85 49.49 54.63 60.14 25.0% 20.9% 19.6% 8.9% 10' EMERGENCY SPILLWAY 46.50 45.96 46.00 46.50 47.45 48.94 49.72 46.50 46.50 47.60 56.98 52.40 55.51 54.09 53.12 24.0% 10.5% 10.3% 71.69 65.82 62.69 63.27 72.29 45.00 44.50 44.50 45.00 35.00' EMERGENCY SPILLWAY 60.60 62.11 63.71 64.96 56.74 60.58 62.22 62.58 58.87 61.04 61.51 71.27 TYPE L RIP RAP WITH BOULDERS PLACED AT OUTFALL FOR ENERGY DISSIPATION (SEE SHEET EC3 FOR SIZING INFORMATION) B M KEYMAP Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G2 GRADING PLAN 27 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES MATCHLINE-SEE SHEET G1 MATCHLINE-SEE SHEET G4 MATCHLINE-SEE SHEET G3 G1 G2 G3 G4 G5 G6 FG=67.75 TF=68.42 LOT 3 A FG=68.40 TF=69.07 LOT 4 A FG=68.61 TF=69.28 LOT 5 A FG=68.76 LOT 6 68.52 65.81 62.58 61.51 B M KEYMAP Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G1 GRADING PLAN 26 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES MATCHLINE-SEE SHEET G2 G1 G2 G3 G4 G5 G6 SS SS SS SS LID VAULT F.O. W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E T T T T T T T T T T T G G G G G G T T T W W W W W W W UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD V AULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT MISTY MEADOW DR DANCING CATTAIL DR CROAKING TOAD DR FLYING MALLARD DR WINDY WILLOW DR MISTY MEADOW DR ZEPHYR RD FALLEN BRANCH DR AUTUMN BREEZE CT BLOCK 1 BLOCK 16 BLOCK 5 BLOCK 4 BLOCK 12 BLOCK 12 BLOCK 10 BLOCK 10 BLOCK 11 BLOCK 7 BLOCK 9 BLOCK 8 BLOCK 9 BLOCK 9 BLOCK 13 BLOCK 14 BLOCK 15 TRACT S DUA TRACT D DUA&EAE TRACT N DU&PAE TRACT O FUTURE DEVELOPMEMT TRACT M TRACT T DUE TRACT C FUTURE PUBLIC PARK TRACT F TRACT P TRACT Q TRACT G TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT TRACT I TRACT H TRACT J BLOCK 8 12" W 12" W X SS VAULT ELEC X X X X X IRR UD UD UD PLANNED HANSEN FARM PLANNED HANSEN FARM DETENTION POND DETENTION POND RED WILLOW DRIVE TRACT U D&PAE TRACT E DGE BLOCK 2 BLOCK 3 FUTURE STORM OUTFALL FOR PROPERTY TO SOUTH (BY OTHERS) WATER QUALITY POND 1 WATER QUALITY POND 2 RAIN GARDEN 1 50' DITCH BUFFER FROM TOP OF BANK 50' DITCH BUFFER FROM TOP OF BANK EXISTING TOP OF DITCH BANK EXISTING TOP OF DITCH BANK NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE FUTURE STORM DRAIN WETLAND BUFFER NATURAL HABITAT BUFFER ZONE STORM DRAIN 7 SEE SHEET ST5 SUBDRAIN LINE 1-4 SEE SHEET SD2 STORM DRAIN 2 SEE SHEET ST2 STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 1 SEE SHEET ST1 STORM DRAIN 4 SEE SHEET ST3 STORM DRAIN 5 SEE SHEET ST4 STORM DRAIN 6 SEE SHEET ST4 SUBDRAIN LINE 1 SEE SHEET SD1 SUBDRAIN LINE 1 SEE SHEET SD1 STORM DRAIN 8 SEE SHEET ST5 X X X X EXISTING FENCE TO REMAIN UNION PACIFIC RAILROAD DITCH LATERAL PROPERTY BOUNDARY (TYP.) X X X PLANNED HANSEN FARM EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 OG1 GRADING PLAN OVERALL 25 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH MATCHLINE-THIS SHEET MATCHLINE-THIS SHEET LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES B M KEYMAP UD UD UD UD S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W UD UD UD UD UD UD UD UD UD UD UD UD S w W S w W w W w W VAULT E VAULT VAULT E E E E E ELEC E ELEC BRKR X X X X X X X X X X FO FO FO FO FO FO FO FO FO E E E E E E E E E MISTY MEADOW DR FALLEN BRANCH DR SDCO 4-2 STA 13+92.35 N: 101337.76 E: 203384.21 SDCO 4-4 w/ 45° BEND STA 12+27.37 N: 101465.30 E: 203247.32 SDCO 4-6 STA 12+27.37 N: 101676.41 E: 202856.48 SDCO 4-11 STA 10+47.70 N: 101575.14 E: 202672.20 11.25° BEND 4-10 STA 10+82.28 N: 101606.78 E: 202688.72 22.5° BEND 4-9 STA 11+02.44 N: 101622.51 E: 202701.37 22.5° BEND 4-8 STA 12+01.93 N: 101673.15 E: 202793.89 11.25° BEND 4-7 STA 12+27.37 N: 101678.00 E: 202838.60 11.25° BEND 4-5 STA 12+27.37 N: 101486.80 E: 203219.85 45° BEND 4-3 STA 12+27.37 N: 101454.52 E: 203248.64 HORIZ DEFLECTION STA 12+27.37 N: 101420.69 E: 203291.88 22.5° BEND 4-1 STA 13+99.60 N: 101331.68 E: 203401.46 38.50 LF 8" PERF. PVC @ 0.50% 18.29 LF 8" PERF. PVC @ 0.50% 124.11 LF 8" PERF. PVC @ 0.50% 54.90 LF 8" PERF. PVC @ 0.50% 10.86 LF 8" PERF. PVC @ 0.50% 34.89 LF 8" PERF. PVC @ 0.50% 409.86 LF 8" PERF. PVC @ 0.50% 17.95 LF 8" PERF. PVC @ 0.50% 44.97 LF 8" PERF. PVC @ 0.50% 105.47 LF 8" PERF. PVC @ 0.50% 20.19 LF 8" PERF. PVC @ 0.50% 35.69 LF 8" PERF. PVC @ 0.50% LOT 1 LOT 2 LOT 8 LOT 6 LOT 5 LOT 7 LOT 12 LOT 16 LOT 15 LOT 14 LOT 13 LOT 10 LOT 11 LOT 9 LOT 13 LOT 14 LOT 9 LOT 10 LOT 11 LOT 12 LOT 7 LOT 8 36' FL-FL 30' EASEMENT REC. NO. 20110070565 67' EASEMENT REC. NO. 20140004033 6' UTILITY EASEMENT PROPERTY BOUNDARY (TYP.) EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE SDCO 4 STA 10+00.00 N: 101305.95 E: 203430.11 PROPOSED 8" WATER 59' ROW 9' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 1 LOT 2 LOT 6 LOT 3 LOT 5 LOT 4 LOT 17 BLOCK 11 SANITARY SEWER LINE 1 SEE SHEET SS2 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 19+75 19+00 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 SDCO 4-2 STA 10+56.80 RIM 4973.4± INV. IN 4948.74 (NW) INV. OUT 4948.74 (E) SDCO 4-4 STA 12+46.66 RIM 4971.3± INV. IN 4949.68 (NW) INV. OUT 4949.68 (S) SDCO 4-6 STA 16+91.41 RIM 4970.2± INV. IN 4951.90 (W) INV. OUT 4951.90 (SE) SDCO 4-11 STA 19+15.69 RIM 4964.4± INV. OUT 4953.02 (NE) 11.25° BEND 4-10 STA 18+80.00 INV. 4952.84 (SW) 22.5° BEND 4-9 INV. 4952.84 (NE) STA 18+59.81 INV. 4952.74 (SW) INV. 4952.74 (NE) 22.5° BEND 4-8 STA 17+54.34 INV. 4952.21 (SW) INV. 4952.21 (E) 11.25° BEND 4-7 STA 17+09.37 INV. 4951.99 (W) INV. 4951.99 (E) 11.25° BEND 4-5 STA 12+81.55 INV. 4949.85 (NW) INV. 4949.85 (SE) 45° BEND 4-3 STA 12+35.80 INV. 4949.63 (N) INV. 4949.63 (SE) HORIZ DEFLECTION STA 11+80.90 INV. 4949.36 (NW) INV. 4949.36 (SE) 22.5° BEND 4-1 STA 10+38.50 INV. 4948.65 (W) INV. 4948.65 (SE) 38.50 LF 8" PERF. PVC @ 0.50% 18.29 LF 8" PERF. PVC @ 0.50% 124.11 LF 8" PERF. PVC @ 0.50% 54.90 LF 8" PERF. PVC @ 0.50% 10.86 LF 8" PERF. PVC @ 0.50% 34.89 LF 8" PERF. PVC @ 0.50% 409.86 LF 8" PERF. PVC @ 0.50% 17.95 LF 8" PERF. PVC @ 0.50% 44.97 LF 8" PERF. PVC @ 0.50% 105.47 LF 8" PERF. PVC @ 0.50% 20.19 LF 8" PERF. PVC @ 0.50% 35.69 LF 8" PERF. PVC @ 0.50% SDCO 4 STA 10+00.00 RIM 4973.3± INV. IN 4948.46 (NW) INV. IN 4948.46 (SE) INV. OUT 4948.46 (SW) PROPOSED GROUND EXISTING GROUND 8" PVC WATER STA.=10+10.00 TOP=4968.60 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 PRIVATE SUBDRAIN LINE 1-4 NORTH EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4. WATER SERVICE MUST HAVE MINIMUM OF 4.5' COVER AND MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWER. ANY STORM SEWER SHALLOWER THAN 5.0' WILL REQUIRE THE WATER SERVICE TO BE INSTALLED UNDER THE PROPOSED STORM SEWER. 5. STORM DRAIN PIPE JOINTS SHALL NOT BE LOCATED OVER UTILITY CROSSINGS. 6. PRIVATE STORM SEWER MATERIAL MAY BE RCP, PVC OR HDPE. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. HDPE MUST BE SMOOTH WALLED INTERIOR. HDPE FITTINGS MAY BE USED FOR PVC INSTALLATIONS. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 7. AREA DRAIN PIPE AND DRAIN BASIN CONNECTIONS TO RCP STORM SHALL USE INSERTA TEE OR APPROVED EQUAL FOR CONNECTION. B M KEYMAP PROFILE SCALE: SD2 PLAN AND PROFILE SUBDRAIN LINE 1-4 24 SD1 SD2 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E G G G G G E E E E E E E E G G G G G G G G G UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD w S W S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W VAULT VAULT VAULT VAULT VAULT E E E E E E VAULT TELE X VAULT F.O. FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E E E T T T T T T T T LOT 1 LOT 13 LOT 15 LOT 14 LOT 13 LOT 12 LOT 11 LOT 10 LOT 9 LOT 8 LOT 1 LOT 2 LOT 3 LOT 1 LOT 2 LOT 3 LOT 15 LOT 13 LOT 14 LOT 1 LOT 2 LOT 10 LOT 11 CROAKING TOAD DR WINDY WILLOW DR MISTY MEADOW DR FALLEN BRANCH DR SDCO 4 STA 14+00.18 N: 101305.95 E: 203430.11 SDCO 3 STA 12+73.67 N: 101213.12 E: 203344.15 SDCO 2 STA 12+27.37 N: 101244.05 E: 203309.71 SDCO 5 STA 17+89.14 N: 101046.04 E: 203719.48 SDCO 6 STA 22+14.61 N: 100761.74 E: 204036.02 SD-FES 1 STA 10+00.00 N: 101074.89 E: 203157.78 227.37 LF 8" PVC @ 0.50% 46.30 LF 8" PVC @ 0.50% 126.51 LF 8" PVC @ 0.50% 388.96 LF 8" PERF. PVC @ 0.50% 425.47 LF 8" PERF. PVC @ 0.50% LOT 6 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 8 LOT 6 LOT 5 LOT 7 LOT 10 LOT 11 LOT 9 LOT 13 LOT 14 TRACT U D&PAE LOT 4 59' ROW 9' UTILITY EASEMENT 9' UTILITY EASEMENT WETLAND BUFFER (TYP.) NATURAL HABITAT BUFFER ZONE 30' EASEMENT REC. NO. 20140004033 15' EASEMENT REC. NO. 20110070565 15' UTILITY EASEMENT 30' UTILITY EASEMENT REC. NO. 20110070565 REC. NO. 20100004033 DITCH LATERAL 5' TRAIL PROPOSED PEDESTRIAN BRIDGE EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK NATURAL HABITAT BUFFER ZONE PROPOSED GRASS LINED SWALE LOT 7 BLOCK 12 BLOCK 10 PROPOSED 8" WATER SANITARY SEWER LINE 1 SEE SHEET SS2 36' FL-FL TRACT C FUTURE PUBLIC PARK PEDESTRIAN ACCESS EASEMENT SUBDRAIN LINE 1-4 SEE SHEET SD2 4940 4945 4950 4955 4960 4965 4970 4975 4980 4985 4940 4945 4950 4955 4960 4965 4970 4975 4980 4985 9+7510+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 22+50 PROPOSED GROUND EXISTING GROUND 18" MIN. SD-FES 1 STA 10+00.00 INV. 4946.46 (NE) 227.37 LF 8" PVC @ 0.50% SDCO 2 STA 12+27.37 RIM 4970.9± INV. IN 4947.60 (SE) INV. OUT 4947.60 (SW) 46.30 LF 8" PVC @ 0.50% SDCO 3 STA 12+73.67 RIM 4971.4± INV. IN 4947.83 (NE) INV. OUT 4947.83 (NW) 126.51 LF 8" PVC @ 0.50% SDCO 4 STA 14+00.18 RIM 4973.3± INV. IN 4948.46 (NW) INV. IN 4948.46 (SE) INV. OUT 4948.46 (SW) 388.96 LF 8" PERF. PVC @ 0.50% SDCO 5 STA 17+89.14 RIM 4967.7± INV. IN 4950.40 (SE) INV. OUT 4950.40 (NW) 425.47 LF 8" PERF. PVC @ 0.50% SDCO 6 STA 22+14.61 RIM 4967.0± INV. OUT 4952.53 (NW) 8" PVC WATER STA.=12+63.67 TOP=4966.90 8" PVC WATER STA.=12+07.37 TOP=4966.30 8" PVC SANITARY STA.=12+17.37 INV.=4949.82 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 PRIVATE SUBDRAIN LINE 1 NORTH EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4. WATER SERVICE MUST HAVE MINIMUM OF 4.5' COVER AND MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWER. ANY STORM SEWER SHALLOWER THAN 5.0' WILL REQUIRE THE WATER SERVICE TO BE INSTALLED UNDER THE PROPOSED STORM SEWER. 5. STORM DRAIN PIPE JOINTS SHALL NOT BE LOCATED OVER UTILITY CROSSINGS. 6. PRIVATE STORM SEWER MATERIAL MAY BE RCP, PVC OR HDPE. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. HDPE MUST BE SMOOTH WALLED INTERIOR. HDPE FITTINGS MAY BE USED FOR PVC INSTALLATIONS. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 7. AREA DRAIN PIPE AND DRAIN BASIN CONNECTIONS TO RCP STORM SHALL USE INSERTA TEE OR APPROVED EQUAL FOR CONNECTION. B M KEYMAP PROFILE SCALE: SD1 PLAN AND PROFILE SUBDRAIN LINE 1 23 SD2 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SD1 INV. OUT 4941.18 (W) 27.54 LF 24" RCP @ 0.50% 8.96 LF 24" RCP @ 0.50% PROPOSED GROUND EXISTING GROUND 2-YR HGL 4945 4950 4955 4960 4965 4970 4975 4980 4945 4950 4955 4960 4965 4970 4975 4980 9+50 10+00 11+00 11+75 PROPOSED GROUND EXISTING GROUND FES 7-1 STA 10+00.00 INV. 4956.97 (NE) 103.87 LF 24" RCP @ 2.00% STMH 7-2 STA 11+03.87 RIM 4964.6± INV. IN 4959.05 (N) INV. OUT 4959.05 (SW) 49.15 LF 18" RCP @ 0.89% INLET 7-3 STA 11+53.02 FL. EL 4964.0± INV. OUT 4959.49 (S) 100-YR HGL E E E E E E E E E E E G G G G G G G G G G G G S S S S S S S S S w W w W w W w W w W w W w W w W UD UD UD UD S w W S w W w W w W VAULT E VAULT E E E X X X X X X X X X X X X X X X X X STMH 7-2 STA 11+03.87 N: 101435.30 E: 202795.87 INLET 7-3 STA 11+53.02 N: 101482.26 E: 202781.36 FES 7-1 STA 10+00.00 N: 101343.76 E: 202746.79 103.87 LF 24" RCP @ 2.00% 49.15 LF 18" RCP @ 0.89% LOT 17 LOT 16 LOT 15 LOT 8 LOT 7 LOT 5 LOT 4 LOT 6 LOT 3 LOT 1 LOT 2 BLOCK 11 SANITARY SEWER LINE 1 SEE SHEET SS2 PROPOSED 8" PVC WATER 5' TRAIL Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4. WATER SERVICE MUST HAVE MINIMUM OF 4.5' COVER AND MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWER. ANY STORM SEWER SHALLOWER THAN 5.0' WILL REQUIRE THE WATER SERVICE TO BE INSTALLED UNDER THE PROPOSED STORM SEWER. 5. STORM DRAIN PIPE JOINTS SHALL NOT BE LOCATED OVER UTILITY CROSSINGS. 6. PRIVATE STORM SEWER MATERIAL MAY BE RCP, PVC OR HDPE. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. HDPE MUST BE SMOOTH WALLED INTERIOR. HDPE FITTINGS MAY BE USED FOR PVC INSTALLATIONS. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 7. AREA DRAIN PIPE AND DRAIN BASIN CONNECTIONS TO RCP STORM SHALL USE INSERTA TEE OR APPROVED EQUAL FOR CONNECTION. ST5 PLAN AND PROFILE STORM DRAIN LINE 7 & 8 22 NORTH B M KEYMAP STORM DRAIN LINE 8 PROFILE SCALE: STORM 7 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R STORM DRAIN LINE 7 PROFILE SCALE: NORTH STORM 8 W w W w W w W w W w W w W w W w W VAULT E E E E CROAKING TOAD DR AUTUMN BREEZE CT STORM DRAIN LINE 1 SEE SHEET ST1 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 BLOCK 9 SANITARY SEWER LINE 2-6 SEE SHEET SS8 PROPOSED 8" PVC WATER 9' UTILITY EASEMENT 63.91 LF 12" RCP @ 0.52% OUTLET 5-2 STA 10+63.91 N: 100458.77 E: 203176.88 FES 5-1 STA 10+00.00 N: 100518.52 E: 203154.18 STORM DRAIN LINE 4 SEE SHEET ST3 LOT 9 LOT 8 LOT 5 LOT 4 LOT 3 LOT 7 LOT 6 SANITARY SEWER LINE 2-6 SEE SHEET SS8 BLOCK 8 TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT 5' TRAIL 2' CONCRETE PAN 4925 4930 4935 4940 4945 4950 4955 4960 4925 4930 4935 4940 4945 4950 4955 4960 9+50 10+00 11+0011+25 PROPOSED GROUND EXISTING GROUND FES 5-1 STA 10+00.00 INV. 4940.77 (S) 63.91 LF 12" RCP @ 0.52% OUTLET 5-2 STA 10+63.91 FL. EL 4943.7± INV. OUT 4941.10 (N) 2-YR HGL E E E E E E E E E E G G G G G G G G G G S S S S S S S S w W w W w W w W w W w W w W w W VAULT X X X X X X X X X X DANCING CATTAIL DR OUTLET 6-2 STA 10+93.37 N: 100290.71 E: 202757.31 FES 6-1 STA 10+17.35 N: 100366.51 E: 202751.49 76.02 LF 12" RCP @ 0.55% LOT 12 LOT 10 LOT 14 LOT 2 LOT 1 LOT 13 LOT 11 SANITARY SEWER LINE 2 SEE SHEET SS4 PROPOSED 8" PVC WATER BLOCK 8 TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT 2' CONCRETE PAN 4925 4930 4935 4940 4945 4950 4955 4960 4925 4930 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 11+50 FES 6-1 STA 10+17.35 INV. 4940.58 (S) 76.02 LF 12" RCP @ 0.55% OUTLET 6-2 STA 10+93.37 FL. EL 4943.2± INV. OUT 4941.00 (N) EXISTING GROUND PROPOSED GROUND 2-YR HGL Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4. WATER SERVICE MUST HAVE MINIMUM OF 4.5' COVER AND MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWER. ANY STORM SEWER SHALLOWER THAN 5.0' WILL REQUIRE THE WATER SERVICE TO BE INSTALLED UNDER THE PROPOSED STORM SEWER. 5. STORM DRAIN PIPE JOINTS SHALL NOT BE LOCATED OVER UTILITY CROSSINGS. 6. PRIVATE STORM SEWER MATERIAL MAY BE RCP, PVC OR HDPE. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. HDPE MUST BE SMOOTH WALLED INTERIOR. HDPE FITTINGS MAY BE USED FOR PVC INSTALLATIONS. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 7. AREA DRAIN PIPE AND DRAIN BASIN CONNECTIONS TO RCP STORM SHALL USE INSERTA TEE OR APPROVED EQUAL FOR CONNECTION. ST4 PLAN AND PROFILE STORM DRAIN LINES 5 & 6 21 NORTH B M KEYMAP STORM DRAIN LINE 5 PROFILE SCALE: STORM DRAIN LINE 6 PROFILE SCALE: NORTH STORM 6 STORM 5 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W W w W w W w W S w W w W V AULT VAULT VAULT E E VAULT H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC S S X X SS SS SS SS SS SS E G G G T T T T W W W W W W MISTY MEADOW DR RED WILLOW DRIVE LOT 3 LOT 12 LOT 13 LOT 10 LOT 11 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 1 LOT 2 LOT 6 LOT 7 LOT 5 LOT 1 LOT 2 LOT 1 LOT 3 LOT 2 LOT 10 LOT 9 LOT 2 LOT 3 LOT 1 TRACT L DU&PAE STORM DRAIN 2 SEE SHEET ST2 SANITARY SEWER LINE 3 SEE SHEET SANITARY SEWER LINE 2 SEE SHEET SS3 TRACT E DG&PAE SANITARY SEWER LINE 1 SEE SHEET SS1 STORM DRAIN LINE 1 SEE SHEET ST1 PROPOSED 8" PVC WATER BLOCK 5 BLOCK 4 BLOCK 2 BLOCK 6 49.48 LF 15" RCP @ 0.50% 54.00 LF 15" RCP @ 0.50% LOT 4 LOT 3 LOT 4 9' UTILITY EASEMENT INLET 3-3 STA 11+03.48 N: 100173.68 INLET 3-2 E: 204106.34 STA 10+49.48 N: 100202.39 E: 204060.60 FES 3-1 STA 10+00.00 N: 100245.90 E: 204037.05 BLOCK 1 ZEPHYR RD DETENTION POND 1 4935 4940 4945 4950 4955 4960 4965 4970 4935 4940 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 11+50 FES 3-1 STA 10+00.00 INV. 4948.81 (SE) 49.48 LF 15" RCP @ 0.50% INLET 3-2 STA 10+49.48 FL. EL 4953.7± INV. IN 4949.06 (SE) INV. OUT 4949.06 (NW) 54.00 LF 15" RCP @ 0.50% INLET 3-3 STA 11+03.48 FL. EL 4953.7± INV. OUT 4949.33 (NW) 8" PVC SANITARY STA.=10+79.96 INV.=4940.42 PROPOSED GROUND EXISTING GROUND 8" PVC WATER LOWERING STA.=10+62.06 TOP=4947.43 18" MIN. 2-YR HGL E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G E E E E E E E G G G G G G G UD UD S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W UD UD UD VAULT VAULT VAULT E E E E E E E E E E X CROAKING TOAD DR MISTY MEADOW DR OUTLET 4-3 STA 11+66.70 N: 100764.03 E: 203281.38 CLEANOUT 4-4 STA 13+27.18 N: 100911.73 E: 203344.12 ADS BASIN 4-2 STA 10+38.88 N: 100638.44 E: 203257.60 FES 4-1 STA 10+00.00 N: 100619.34 E: 203223.73 160.47 LF 4" PERF. PVC @ 0.20% 38.88 LF 18" HDPE @ 0.20% 127.82 LF 18" HDPE @ 0.20% STORM DRAIN LINE 1 SEE SHEET ST1 STORM DRAIN LINE 1 SEE SHEET ST1 LOT 2 LOT 3 LOT 8 LOT 6 LOT 5 LOT 7 LOT 4 LOT 9 LOT 8 LOT 7 LOT 6 LOT 12 LOT 13 LOT 10 LOT 11 LOT 8 LOT 6 LOT 7 LOT 11 LOT 9 LOT 10 BLOCK 10 BLOCK 9 BLOCK 13 SANITARY SEWER LINE 2-6 SEE SHEET SANITARY SEWER LINE 1 SEE SHEET PROPOSED 8" WATERLINE 9' UTILITY EASEMENT 9' UTILITY EASEMENT PROPOSED GRASS LINED SWALE 4930 4935 4940 4945 4950 4955 4960 4965 4930 4935 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 14+50 FES 4-1 STA 10+00.00 INV. 4941.37 (NE) 38.88 LF 18" HDPE @ 0.20% ADS BASIN 4-2 STA 10+38.88 RIM 4943.6± INV. IN 4941.45 (N) INV. OUT 4941.45 (SW) 127.82 LF 18" HDPE @ 0.20% OUTLET 4-3 STA 11+66.70 RIM 4945.5± INV. IN 4941.70 (NE) INV. OUT 4941.70 (S) 160.47 LF 4" PERF. PVC @ 0.20% CLEANOUT 4-4 STA 13+27.18 RIM 4944.5± INV. OUT 4942.02 (SW) EXISTING GROUND 2-YR HGL PROPOSED GROUND Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4. WATER SERVICE MUST HAVE MINIMUM OF 4.5' COVER AND MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWER. ANY STORM SEWER SHALLOWER THAN 5.0' WILL REQUIRE THE WATER SERVICE TO BE INSTALLED UNDER THE PROPOSED STORM SEWER. 5. STORM DRAIN PIPE JOINTS SHALL NOT BE LOCATED OVER UTILITY CROSSINGS. 6. PRIVATE STORM SEWER MATERIAL MAY BE RCP, PVC OR HDPE. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. HDPE MUST BE SMOOTH WALLED INTERIOR. HDPE FITTINGS MAY BE USED FOR PVC INSTALLATIONS. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 7. AREA DRAIN PIPE AND DRAIN BASIN CONNECTIONS TO RCP STORM SHALL USE INSERTA TEE OR APPROVED EQUAL FOR CONNECTION. ST3 PLAN AND PROFILE STORM DRAIN LINES 3 & 4 20 NORTH B M KEYMAP STORM DRAIN LINE 3 PROFILE SCALE: STORM DRAIN LINE 4 PROFILE SCALE: NORTH STORM 4 STORM 3 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R G G G G G G G G G G G G G G E E E E E E E E E E E G G G G G G G G G S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W W w W S w W w W w W V AULT VAULT VAULT VAULT VAULT E E VAULT VAULT W H Y D W ELEC VAULT ELEC H Y D S S S X X X X X X X X X X X X X X X X X SS SS SS SS SS SS SS SS SS SS SS SS SS SS LID W W W FO FO FO FO FO T T T T T G G G G G G G G G G G T T T T T T W W W W W W W W W W W W W W ZEPHYR RD MISTY MEADOW DR ROSEN DRIVE RED WILLOW DRIVE LOT 16 LOT 22 LOT 21 LOT 20 LOT 19 LOT 18 LOT 17 LOT 3 LOT 15 LOT 14 LOT 12 LOT 13 LOT 10 LOT 11 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 1 LOT 2 LOT 6 LOT 7 LOT 5 LOT 1 LOT 2 LOT 1 LOT 8 LOT 10 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 10 LOT 9 LOT 7 LOT 1 LOT 2 LOT 3 LOT 4 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 2 LOT 3 LOT 1 TRACT L DU&PAE TRACT N DU&PAE STORM DRAIN 3 SEE SHEET ST3 SANITARY SEWER LINE 3-1 SEE SHEET SS9 SSMH 2-5 STA 13+42.26 N: 100001.12 E: 204174.84 FES 2-6 STA 16+99.42 N: 100001.01 E: 204532.01 SSMH 2-4 STA 12+53.23 N: 100090.14 E: 204174.87 INLET 2-3 STA 11+86.00 N: 100153.25 E: 204198.03 FES 2-1 STA 10+00.00 N: 100266.16 E: 204050.22 67.23 LF 15" RCP @ 0.50% 89.03 LF 15" RCP @ 0.93% 357.17 LF 15" RCP @ 1.00% 147.56 LF 15" RCP @ 0.63% SANITARY SEWER LINE 2 SEE SHEET SS3 TRACT E DG&PAE SANITARY SEWER LINE 1 SEE SHEET SS1 SANITARY SEWER LINE 3 SEE SHEET SS8 STORM DRAIN LINE 1 SEE SHEET ST1 PROPOSED 8" WATERLINE BLOCK 1 BLOCK 5 BLOCK 4 BLOCK 2 BLOCK 2 BLOCK 3 BLOCK 6 INLET 2-2 STA 11+47.56 N: 100176.63 E: 204167.51 38.44 LF 15" RCP @ 0.50% 4935 4940 4945 4950 4955 4960 4965 4970 4935 4940 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+50 FES 2-1 STA 10+00.00 RIM 4949.8± INV. IN 4948.37 (SE) 147.56 LF 15" RCP @ 0.63% INLET 2-3 STA 11+86.00 RIM 4954.3± INV. IN 4949.49 (S) INV. OUT 4949.49 (NW) 67.23 LF 15" RCP @ 0.50% SSMH 2-4 STA 12+53.23 RIM 4955.1± INV. IN 4949.83 (S) INV. OUT 4949.83 (N) 89.03 LF 15" RCP @ 0.93% SSMH 2-5 STA 13+42.26 RIM 4957.0± INV. IN 4950.65 (E) INV. OUT 4950.65 (N) 357.17 LF 15" RCP @ 1.00% FES 2-6 STA 16+99.42 RIM 4955.7± INV. OUT 4954.22 (W) PROPOSED GROUND EXISTING GROUND 8" PVC SANITARY STA.=10+82.67 INV.=4941.26 8" PVC WATER LOWERING STA.=10+60.12 TOP=4946.97 18" MIN. 8" PVC WATER LOWERING STA.=13+52.26 TOP=4948.50 18" MIN. 8" PVC WATER LOWERING STA.=15+34.26 TOP=4950.61 18" MIN. INLET 2-2 STA 11+47.56 RIM 4952.7± INV. IN 4949.30 (SE) INV. OUT 4949.30 (NW) 38.44 LF 15" RCP @ 0.50% 2-YR HGL Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4. WATER SERVICE MUST HAVE MINIMUM OF 4.5' COVER AND MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWER. ANY STORM SEWER SHALLOWER THAN 5.0' WILL REQUIRE THE WATER SERVICE TO BE INSTALLED UNDER THE PROPOSED STORM SEWER. 5. STORM DRAIN PIPE JOINTS SHALL NOT BE LOCATED OVER UTILITY CROSSINGS. 6. PRIVATE STORM SEWER MATERIAL MAY BE RCP, PVC OR HDPE. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. HDPE MUST BE SMOOTH WALLED INTERIOR. HDPE FITTINGS MAY BE USED FOR PVC INSTALLATIONS. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 7. AREA DRAIN PIPE AND DRAIN BASIN CONNECTIONS TO RCP STORM SHALL USE INSERTA TEE OR APPROVED EQUAL FOR CONNECTION. ST2 PLAN AND PROFILE STORM DRAIN LINE 2 19 NORTH B M KEYMAP STORM DRAIN LINE 2 PROFILE SCALE: CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R E E E E E E E E E G G G G G G G G G G G G E E E E E E E G G G G S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W UD UD UD VAULT VAULT VAULT VAULT VAULT VAULT VAULT E E E E E E E E E VAULT E LOT 2 LOT 9 LOT 8 LOT 10 LOT 11 LOT 3 LOT 4 LOT 3 LOT 5 LOT 6 LOT 7 LOT 9 LOT 10 LOT 7 LOT 8 LOT 12 LOT 10 LOT 11 LOT 4 LOT 3 LOT 5 LOT 6 LOT 7 LOT 8 LOT 6 LOT 7 LOT 8 LOT 9 LOT 8 LOT 9 INLET 1-7 STA 16+74.61 N: 100452.33 E: 203889.23 INLET 1-6 STA 16+39.91 N: 100465.74 E: 203857.22 SSMH 1-8 STA 17+72.73 N: 100409.27 E: 203977.39 INLET 1-5 STA 14+31.70 N: 100549.55 E: 203666.63 INLET 1-4 STA 13+96.99 N: 100563.27 E: 203634.75 INLET 1-3 STA 11+88.34 N: 100643.13 E: 203441.98 INLET 1-2 STA 11+58.33 N: 100654.60 E: 203414.26 OUTLET 1-9 STA 18+26.79 N: 100360.81 E: 204001.37 FES 1-1 STA 10+00.00 N: 100757.89 E: 203294.26 34.71 LF 24" RCP @ 0.40% 208.20 LF 24" RCP @ 0.40% 34.71 LF 18" RCP @ 0.40% 98.11 LF 18" RCP @ 0.40% 54.06 LF 18" RCP @ 0.40% 158.33 LF 24" RCP @ 0.40% 30.00 LF 24" RCP @ 0.41% STORM DRAIN LINE 3 SEE SHEET ST3 LOT 6 LOT 7 LOT 5 LOT 1 LOT 5 LOT 4 LOT 10 LOT 11 LOT 9 LOT 8 LOT 7 TRACT M LOT 6 LOT 2 CROAKING TOAD DR FLYING MALLARD DR WINDY WILLOW DR ZEPHYR RD MISTY MEADOW DR TRACT S DUA TRACT D DUA&EAE STORM DRAIN LINE 2 SEE SHEET ST2 STORM DRAIN LINE 4 SEE SHEET ST3 SANITARY SEWER LINE 3 SEE SHEET SS8 BLOCK 9 BLOCK 5 BLOCK 13 BLOCK 1 BLOCK 4 BLOCK 16 SANITARY SEWER LINE 2-6 SEE SHEET SS8 SANITARY SEWER LINE 2-5 SEE SHEET SS7 SANITARY SEWER LINE 2-4 SEE SHEET SS6 ALLEY 1 ALLEY 2 4930 4935 4940 4945 4950 4955 4960 4965 4970 4930 4935 4940 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 18+75 98.11 LF 18" RCP @ 0.40% SSMH 1-8 STA 17+72.73 RIM 4954.6± INV. IN 4948.09 (SE) INV. OUT 4948.09 (NW) 54.06 LF 18" RCP @ 0.40% OUTLET 1-9 STA 18+26.79 FL. EL 4950.0± INV. OUT 4948.31 (NW) FES 1-1 STA 10+00.00 INV. 4944.50 (SE) 158.33 LF 24" RCP @ 0.40% INLET 1-2 STA 11+58.33 FL. EL 4950.5± INV. IN 4945.13 (E) INV. OUT 4945.13 (NW) 30.00 LF 24" RCP @ 0.41% INLET 1-3 STA 11+88.34 FL. EL 4950.5± INV. IN 4945.25 (SE) INV. OUT 4945.25 (W) INLET 1-4 STA 13+96.99 FL. EL 4953.7± INV. IN 4946.59 (SE) INV. OUT 4946.59 (NW) 34.71 LF 24" RCP @ 0.40% INLET 1-5 STA 14+31.70 FL. EL 4953.8± INV. IN 4946.73 (SE) INV. OUT 4946.73 (NW) 208.20 LF 24" RCP @ 0.40% INLET 1-6 STA 16+39.91 FL. EL 4955.3± INV. IN 4947.56 (SE) INV. OUT 4947.56 (NW) 34.71 LF 18" RCP @ 0.40% INLET 1-7 STA 16+74.61 FL. EL 4955.3± INV. IN 4947.70 (SE) INV. OUT 4947.70 (NW) PROPOSED GROUND EXISTING GROUND 8" PVC SANITARY STA.=11+78.28 INV.=4940.51 8" PVC SANITARY STA.=14+17.93 INV.=4941.71 8" PVC SANITARY STA.=16+59.10 INV.=4943.19 8" PVC WATER LOWERING STA.=11+68.28 TOP=4943.42 18" MIN. 8" PVC WATER LOWERING STA.=14+07.48 TOP=4944.92 18" MIN. 8" PVC WATER LOWERING STA.=16+48.83 TOP=4945.89 18" MIN. 208.66 LF 24" RCP @ 0.64% 100-YR HGL Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 STORM DRAIN LINE 1 NORTH EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4. WATER SERVICE MUST HAVE MINIMUM OF 4.5' COVER AND MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWER. ANY STORM SEWER SHALLOWER THAN 5.0' WILL REQUIRE THE WATER SERVICE TO BE INSTALLED UNDER THE PROPOSED STORM SEWER. 5. STORM DRAIN PIPE JOINTS SHALL NOT BE LOCATED OVER UTILITY CROSSINGS. 6. PRIVATE STORM SEWER MATERIAL MAY BE RCP, PVC OR HDPE. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. HDPE MUST BE SMOOTH WALLED INTERIOR. HDPE FITTINGS MAY BE USED FOR PVC INSTALLATIONS. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 7. AREA DRAIN PIPE AND DRAIN BASIN CONNECTIONS TO RCP STORM SHALL USE INSERTA TEE OR APPROVED EQUAL FOR CONNECTION. B M KEYMAP PROFILE SCALE: ST1 PLAN AND PROFILE STORM DRAIN LINE 1 18 STORM 1 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W S w W VAULT VAULT VAULT VAULT E VAULT V AULT ELEC H Y D S X SS SS SS SS SS SS SS SS T T T T W W W W W W W W SSMH 3-3 STA 10+00.00 N: 100087.55 E: 204376.86 LOT 1 LOT 3 LOT 2 LOT 9 LOT 8 LOT 7 TRACT L DU&PAE BLOCK 1 LOT 8 LOT 10 LOT 5 LOT 4 LOT 7 LOT 9 LOT 10 LOT 9 LOT 12 LOT 13 LOT 10 LOT 11 LOT 16 LOT 21 LOT 20 LOT 19 LOT 18 LOT 17 LOT 15 LOT 14 LOT 6 LOT 1 LOT 4 LOT 3 LOT 2 LOT 5 LOT 6 LOT 7 LOT 8 SANITARY SEWER LINE 3 SEE SHEET SS8 BLOCK 2 BLOCK 3 9' UTILITY EASEMENT 4.5' SIDEWALK 4' SIDEWALK 8' UTILITY EASEMENT 67.50 LF 8" PVC @ 0.50% SSMH 3-3A STA 10+67.50 N: 100155.05 E: 204376.89 PROPOSED 8" PVC WATER SANITARY SEWER LINE 3-1 SEE LEFT E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E G G G G G G G G G S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W S w W w W w W V AULT VAULT VAULT VAULT VAULT E VAULT VAULT VAULT ELEC H Y D S X X X X X X X X X SS SS SS SS SS SS SS SS SS SS G G G G G G G G G G T T T T T T W W W W W W W W W W W STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 SANITARY SEWER LINE 1 SEE SHEET SS1 LOT 1 LOT 2 LOT 3 LOT 3 LOT 9 LOT 8 LOT 7 LOT 5 LOT 4 LOT 1 LOT 2 LOT 1 TRACT L DU&PAE BLOCK 1 BLOCK 4 LOT 8 LOT 10 LOT 4 LOT 5 LOT 10 LOT 9 LOT 7 LOT 9 LOT 12 LOT 13 LOT 10 LOT 11 TRACT M SSMH 3-1 STA 10+00.00 N: 100158.68 E: 204207.50 LOT 6 LOT 16 LOT 22 LOT 20 LOT 21 LOT 19 LOT 18 LOT 14 LOT 15 LOT 17 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 8 LOT 7 LOT 6 LOT 5 BLOCK 2 BLOCK 3 9' UTILITY EASEMENT 4.5' SIDEWALK 4' SIDEWALK 8' UTILITY EASEMENT 76.15 LF 8" PVC @ 1.97% SSMH 3-1A STA 10+76.15 N: 100205.89 E: 204267.25 76.15 LF 8" PVC @ 1.50% SSMH 3-1B STA 11+52.29 N: 100231.32 E: 204339.03 236.65 LF 8" PVC @ 3.00% SSMH 3-1C STA 13+88.95 N: 100232.46 E: 204575.67 PROPOSED 8" PVC WATER SANITARY SEWER LINE 3-3 SEE RIGHT SANITARY SEWER LINE 3 SEE SHEET SS8 4935 4940 4945 4950 4955 4960 4965 4970 4975 4935 4940 4945 4950 4955 4960 4965 4970 4975 9+50 10+00 11+00 12+00 13+00 14+0014+25 PROPOSED GROUND EXISTING GROUND SSMH 3-1 STA 10+00.00 RIM 4954.6± INV. IN 4942.39 (S) INV. IN 4942.39 (NE) INV. OUT 4942.19 (NW) 76.15 LF 8" PVC @ 1.97% SSMH 3-1A STA 10+76.15 RIM 4956.2± INV. IN 4944.09 (E) INV. OUT 4943.89 (SW) 76.15 LF 8" PVC @ 1.50% SSMH 3-1B STA 11+52.29 RIM 4957.7± INV. IN 4945.43 (E) INV. OUT 4945.23 (W) 236.65 LF 8" PVC @ 3.00% SSMH 3-1C STA 13+88.95 RIM 4964.5± INV. OUT 4952.53 (W) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SANITARY SEWER LINE 3-1 NORTH PROFILE SCALE: Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SANITARY CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. W EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED WATER SERVICE W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED SUBDRAIN SD B M KEYMAP SS9 PLAN AND PROFILE SANITARY SEWER LINES 3-1 & 3-3 17 SS9 SANITARY SEWER LINE 3-3 PROFILE SCALE: NORTH G G G G G G G G G G G G G G G G G G G G G G G S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W VAULT VAULT VAULT VAULT X X X SSMH 2-6 STA 10+00.00 N: 100141.96 E: 203060.84 LOT 7* LOT 6* LOT 8* LOT 7* LOT 3* LOT 5* LOT 4* LOT 10* LOT 9* LOT 8* LOT 2* LOT 3* LOT 1 LOT 5* LOT 4* LOT 3* LOT 4* BLOCK 8 BLOCK 9 LOT 10* LOT 9* LOT 2* LOT 1* 9' UTILITY EASEMENT 4.5' SIDEWALK LOT 6 PROPOSED 8" PVC WATER 93.35 LF 8" PVC @ 0.50% SSMH 2-6A STA 10+93.35 N: 100235.31 E: 203060.84 87.27 LF 8" PVC @ 0.50% SSMH 2-6B STA 11+80.62 N: 100293.97 E: 203125.45 BLOCK 7 SANITARY SEWER LINE 2 SEE SHEET SS4 DANCING CATTAIL DR AUTUMN BREEZE CT E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E G G G G G G G G G S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W S w W w W w W VAULT VAULT VAULT VAULT VAULT E VAULT VAULT H Y D W VAULT ELEC H Y D S S S X X X X X X X X X X SS SS SS SS SS SS SS SS SS SS SS SS G G G G G G G G G G T T T T T T W W W W W W W W W W W W W W SSMH 3-4 STA 14+56.23 N: 100087.52 E: 204486.36 SSMH 3-3 STA 13+46.73 N: 100087.55 E: 204376.86 109.50 LF 8" PVC @ 1.00% STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 SANITARY SEWER LINE 1 SEE SHEET SS1 SANITARY SEWER LINE 3-1 SEE SHEET SS9 LOT 1 LOT 2 LOT 3 LOT 3 LOT 9 LOT 8 LOT 7 LOT 5 LOT 4 LOT 1 LOT 2 LOT 1 TRACT L DU&PAE LOT 1 TRACT E DG&PAE TRACT T DUE BLOCK 1 BLOCK 4 LOT 8 LOT 10 LOT 4 LOT 5 LOT 10 LOT 9 LOT 7 LOT 9 LOT 12 LOT 13 LOT 10 LOT 11 TRACT M SSMH 3 STA 10+00.00 N: 100223.16 E: 204123.03 106.27 LF 8" PVC @ 0.40% 71.08 LF 8" PVC @ 1.86% 169.38 LF 8" PVC @ 1.34% SSMH 3-2 STA 11+77.35 N: 100087.61 E: 204207.48 SSMH 3-1 STA 11+06.27 N: 100158.68 E: 204207.50 LOT 6 LOT 16 LOT 22 LOT 21 LOT 20 LOT 19 LOT 18 LOT 15 LOT 17 LOT 14 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 8 LOT 7 LOT 6 LOT 5 SANITARY SEWER LINE 3-3 SEE SHEET SS9 BLOCK 2 BLOCK 3 PROPOSED 8" PVC WATER 9' UTILITY EASEMENT 4.5' SIDEWALK 4' SIDEWALK 8' UTILITY EASEMENT MISTY MEADOW DR ZEPHYR RD RED WILLOW DRIVE 4930 4935 4940 4945 4950 4955 4960 4965 4970 4930 4935 4940 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 SSMH 3 STA 10+00.00 RIM 4954.4± INV. IN 4941.66 (NE) INV. IN 4941.76 (SE) INV. OUT 4941.46 (SW) 106.27 LF 8" PVC @ 0.40% SSMH 3-1 STA 11+06.27 RIM 4954.6± INV. IN 4942.39 (S) INV. IN 4942.39 (NE) INV. OUT 4942.19 (NW) 71.08 LF 8" PVC @ 1.86% SSMH 3-2 STA 11+77.35 RIM 4956.0± INV. IN 4944.01 (E) INV. OUT 4943.71 (N) 169.38 LF 8" PVC @ 1.34% SSMH 3-3 STA 13+46.73 RIM 4958.2± INV. IN 4946.48 (E) INV. IN 4946.58 (N) INV. OUT 4946.28 (W) 109.50 LF 8" PVC @ 1.00% SSMH 3-4 STA 14+56.23 RIM 4959.5± INV. OUT 4947.57 (W) PROPOSED GROUND EXISTING GROUND 8" PVC WATER STA.=11+87.35 TOP=4951.64 8" PVC WATER STA.=13+36.73 TOP=4953.91 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SANITARY SEWER LINE 2-6 NORTH PROFILE SCALE: Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SANITARY CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. W EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED WATER SERVICE W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED SUBDRAIN SD B M KEYMAP SS8 PLAN AND PROFILE SANITARY SEWER LINE 2-6 & 3 16 SS8 SANITARY SEWER LINE 3 PROFILE SCALE: NORTH E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W UD UD UD w W VAULT VAULT VAULT VAULT VAULT VAULT E E E E E E E E E E E E SSMH 2-5C STA 15+76.46 N: 100705.31 SSMH 2-5 E: 203455.04 STA 10+00.00 N: 100141.93 E: 203369.87 SSMH 2-5B STA 13+98.83 N: 100539.44 E: 203391.49 177.63 LF 8" PVC @ 0.40% 177.63 LF 8" PVC @ 0.60% 187.67 LF 8" PVC @ 4.55% LOT 1 LOT 2 LOT 3 LOT 12 LOT 10 LOT 11 LOT 13 LOT 4 LOT 12 LOT 13 LOT 1 LOT 10* LOT 9* LOT 8* LOT 2* LOT 3* LOT 1* LOT 4* LOT 15* LOT 13* LOT 14* LOT 17* LOT 16* LOT 3 LOT 5 LOT 4 LOT 2 LOT 10 LOT 11 PROPOSED 8" BLOCK 9 BLOCK 13 BLOCK 14 SANITARY SEWER LINE 2 SEE SHEET SS3 4.5' SIDEWALK 9' UTILITY EASEMENT LOT 5 LOT 6 LOT 12* LOT 7* LOT 6 LOT 7 LOT 8 LOT 9 TRACT P TRACT Q TRACT G TRACT F SSMH 2-5D STA 17+64.13 N: 100858.45 E: 203563.53 LOT 11* LOT 10* LOT 9* LOT 8* LOT 7* LOT 8* LOT 9* LOT 5* LOT 6* LOT 10 LOT 11 STORM DRAIN 1 SEE SHEET ST1 4.5' SIDEWALK 9' UTILITY EASEMENT STORM DRAIN 4 SEE SHEET ST3 DANCING CATTAIL DR CROAKING TOAD DR 221.20 LF 8" PVC @ 0.40% SSMH 2-5A STA 12+21.20 N: 100363.13 E: 203369.87 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SANITARY SEWER LINE 2-5 NORTH PROFILE SCALE: Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SANITARY CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. W EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED WATER SERVICE W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED SUBDRAIN SD B M KEYMAP SS7 PLAN AND PROFILE SANITARY SEWER LINE 2-5 15 SS6 G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G E E E G G G G S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W V AULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT E E E E E E E E X X X X X X X SSMH 2-4B STA 13+99.13 N: 100538.09 E: 203643.24 SSMH 2-4 STA 10+00.00 N: 100141.93 E: 203610.87 177.93 LF 8" PVC @ 1.45% 199.56 LF 8" PVC @ 5.40% LOT 2 LOT 3 LOT 12 LOT 10 LOT 11 LOT 15 LOT 13 LOT 14 LOT 1 LOT 2 LOT 4 LOT 3 LOT 5 LOT 10 LOT 8 LOT 9 TRACT D DUA&EAE LOT 4 LOT 1 LOT 15 LOT 13 LOT 14 LOT 17 LOT 16 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 9 LOT 12 LOT 10 LOT 11 LOT 13 LOT 3 LOT 5 LOT 4 LOT 2 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 6 PROPOSED 8" PVC WATER BLOCK 6 BLOCK 13 BLOCK 14 BLOCK 15 BLOCK 16 SANITARY SEWER LINE 2 SEE SHEET SS3 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 221.20 LF 8" PVC @ 0.40% SSMH 2-4A STA 12+21.20 N: 100363.13 E: 203610.87 SSMH 2-4C STA 15+98.69 N: 100706.55 E: 203750.24 LOT 5 LOT 6 LOT 12 LOT 7 LOT 6 LOT 7 LOT 8 LOT 7 LOT 6 LOT 8 LOT 6 LOT 7 LOT 9 TRACT P TRACT Q TRACT G TRACT I TRACT H TRACT F SANITARY SEWER LINE 1 SEE SHEET SS2 DANCING CATTAIL DR FLYING MALLARD DR STORM DRAIN 1 SEE SHEET ST1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SANITARY SEWER LINE 2-4 NORTH PROFILE SCALE: Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SANITARY CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. W EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED WATER SERVICE W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED SUBDRAIN SD B M KEYMAP SS6 PLAN AND PROFILE SANITARY SEWER LINE 2-4 14 SS6 G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G E E E E E E E G G G G w W S S S S S S S S S S S S S S S S S S S S S S S S S S SS S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w w W w W w W w W w W VAULT VAULT VAULT E E E E SSMH 2-2B STA 12+23.89 N: 100449.74 E: 203869.53 SSMH 2-2 STA 10+00.00 N: 100227.44 E: 203851.87 LOT 1 LOT 2 LOT 4 LOT 3 LOT 5 LOT 10 LOT 8 LOT 9 LOT 3 LOT 4 LOT 3 LOT 1 LOT 2 TRACT D DUA&EAE LOT 2 LOT 1 TRACT T DUE BLOCK 6 SANITARY SEWER LINE 2 SEE SHEET SS3 9' UTILITY EASEMENT 4.5' SIDEWALK STORM DRAIN 1 SEE SHEET ST1 TRACT J PROPOSED 8" PVC WATER LOT 1 LOT 9 LOT 12 LOT 10 LOT 11 LOT 13 LOT 3 LOT 5 LOT 4 LOT 2 LOT 6 LOT 7 LOT 5 BLOCK 15 BLOCK 16 LOT 8 LOT 6 LOT 7 TRACT I TRACT H SANITARY SEWER LINE 1 SEE SHEET SS1 SSMH 2-2C STA 13+34.21 N: 100543.15 E: 203928.22 LOT 4 98.55 LF 8" PVC @ 3.50% 110.32 LF 8" PVC @ 5.00% 125.34 LF 8" PVC @ 3.00% WINDY WILLOW DR MISTY MEADOW DR SSMH 2-2A STA 11+25.34 N: 100352.79 E: 203851.87 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SANITARY SEWER LINE 2-2 NORTH PROFILE SCALE: Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SANITARY CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. W EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED WATER SERVICE W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED SUBDRAIN SD B M KEYMAP SS5 PLAN AND PROFILE SANITARY SEWER LINE 2-2 13 SS5 G G G G G G G G G G G G G G G G G G S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w w w W w W VAULT VAULT VAULT VAULT X X X X X X X X X X X X X X X X X SSMH 2-6 STA 21+14.54 N: 100141.96 E: 203060.84 SSMH 2-7 STA 23+24.32 N: 100141.96 E: 202851.06 SSMH 2-8 STA 24+11.27 N: 100175.24 E: 202770.74 209.78 LF 8" PVC @ 0.40% 86.95 LF 8" PVC @ 0.40% LOT 7* LOT 6* LOT 7* LOT 8* LOT 5* LOT 5* LOT 4* LOT 3* BLOCK 8 LOT 9* LOT 10* LOT 12* LOT 13* LOT 11* LOT 14* LOT 2* LOT 1* BLOCK 8 BLOCK 7 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK SANITARY SEWER LINE 2-6 SEE SHEET SS8 LOT 6* PROPOSED 8" PVC WATER 5' TRAIL AUTUMN BREEZE CT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SANITARY SEWER LINE 2 NORTH PROFILE SCALE: Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SANITARY CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. W EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED WATER SERVICE W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED SUBDRAIN SD B M KEYMAP SS4 PLAN AND PROFILE SANITARY SEWER LINE 2 12 LINE MATCH STA 20+50 MATCH LINE SEE SHEET SS3 STA 20+50 SS4 SS3 PROPOSED GROUND 8" PVC WATER STA.=10+12.25 TOP=4949.69 8" PVC WATER STA.=18+15.51 TOP=4942.81 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E G G G G G G G G G G E E E E E E E E E E E G G G G G G G G G G G G G G S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W VAULT VAULT VAULT VAULT VAULT VAULT VAULT E E E E E E E VAULT S X X X X X X X X X X X X X X X X X X SSMH 2-2 STA 12+37.99 N: 100227.44 E: 203851.87 SSMH 2-4 STA 15+64.51 N: 100141.93 E: 203610.87 SSMH 2-5 STA 18+05.51 N: 100141.93 E: 203369.87 111.17 LF 8" PVC @ 1.66% 85.51 LF 8" PVC @ 0.40% 241.00 LF 8" PVC @ 0.40% 241.00 LF 8" PVC @ 0.40% 309.03 LF 8" PVC @ 0.40% STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 SANITARY SEWER LINE 1 SEE SHEET SS1 LOT 2 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 1 TRACT E DG&PAE TRACT T DUE BLOCK 4 BLOCK 6 SSMH 2-3 STA 13+23.51 N: 100141.93 E: 203851.87 SANITARY SEWER LINE 2-2 SEE SHEET SS5 134.04 LF 8" PVC @ 0.40% 103.96 LF 8" PVC @ 0.40% LOT 7* LOT 1 LOT 3* LOT 6* LOT 5* LOT 1* LOT 2* LOT 4* LOT 10 LOT 9 LOT 8 LOT 2* LOT 3* LOT 1* LOT 4* LOT 15* LOT 13* LOT 14* LOT 17* LOT 16* LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 9 LOT 12 LOT 10 LOT 11 LOT 13 LOT 3 LOT 5 LOT 4 LOT 2 LOT 6 LOT 7 LOT 5 LOT 7 LOT 8 LOT 9 LOT 10 LOT 4 LOT 5 LOT 11 LOT 6 PROPOSED 8" PVC WATER BLOCK 6 BLOCK 8 BLOCK 13 BLOCK 9 BLOCK 16 BLOCK 15 BLOCK 14 LOT 6* 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT SANITARY SEWER LINE 2-4 SEE SHEET SS6 SANITARY SEWER LINE 2-5 SEE SHEET SS7 DANCING CATTAIL DR CROAKING TOAD DR FLYING MALLARD DR WINDY WILLOW DR ZEPHYR RD SSMH 2-1 STA 11+03.96 N: 100227.44 E: 203985.91 SSMH 2 STA 10+00.00 N: 100175.80 E: 204076.13 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SANITARY SEWER LINE 2 NORTH PROFILE SCALE: Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SANITARY CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. W EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED WATER SERVICE W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED SUBDRAIN SD B M KEYMAP SS3 PLAN AND PROFILE SANITARY SEWER LINE 2 11 LINE MATCH STA 20+50 MATCH LINE SEE SHEET SS4 STA 20+50 SS4 SS3 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E G G G G G G G G G G G G G E E E E E E E G G G G G G G G UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W UD UD UD UD UD UD UD S w W S w W w W w W w W VAULT E VAULT VAULT VAULT VAULT VAULT E E E E E E E E E E X X X X X X X X X X X X FO FO FO FO FO E E E E E SSMH 8 STA 25+42.16 N: 101154.09 E: 203394.91 SSMH 9 STA 28+52.87 N: 101361.71 E: 203163.75 SSMH 10 STA 31+64.55 N: 101506.13 E: 202887.55 SSMH 11 STA 32+46.67 N: 101493.76 E: 202806.37 SSMH 7 STA 22+19.16 N: 100938.26 E: 203635.21 297.44 LF 8" PVC @ 0.40% 323.00 LF 8" PVC @ 0.40% 310.71 LF 8" PVC @ 0.40% 311.68 LF 8" PVC @ 0.40% 82.12 LF 8" PVC @ 0.50% 187.67 LF 8" PVC @ 4.55% LOT 1 LOT 4 LOT 2 LOT 6 LOT 3 LOT 1 LOT 2 LOT 3 LOT 12 LOT 15 LOT 13 LOT 14 LOT 6 LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 1 LOT 2 LOT 3 LOT 8 LOT 6 LOT 5 LOT 7 LOT 12 LOT 17 LOT 16 LOT 15 LOT 14 LOT 10 LOT 13 LOT 11 LOT 9 LOT 16 LOT 15 LOT 13 LOT 14 LOT 12 LOT 11 LOT 9 LOT 10 LOT 8 LOT 7 LOT 5 LOT 4 TRACT U D&PAE BLOCK 14 BLOCK 13 BLOCK 12 BLOCK 10 BLOCK 11 LOT 4 LOT 12 LOT 13 PROPOSED 8" PVC WATER 5' TRAIL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK STORM DRAIN 7 SEE SHEET ST5 SANITARY SEWER LINE 2-5 SEE SHEET SS7 CROAKING TOAD DR FALLEN BRANCH DR MISTY MEADOW DR SUBDRAIN LINE 1 SEE SHEET SD1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SANITARY SEWER LINE 1 NORTH PROFILE SCALE: Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SANITARY CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. W EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED WATER SERVICE W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED SUBDRAIN SD B M KEYMAP SS2 PLAN AND PROFILE SANITARY SEWER LINE 1 10 LINE MATCH STA 20+50 MATCH LINE SEE SHEET SS1 STA 20+50 SS1 SS2 S S S S S S S S S S S S S S S S S S S S S S S S S w W w w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W S w W w W V AULT VAULT VAULT VAULT E VAULT VAULT H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC S S X SS SS SS SS SS SS E G G G G T T T T W W W W W W W SSMH 3-3 SSMH 4 STA 13+56.27 N: 100302.63 E: 204200.78 EX. SSMH 1 STA 10+00.00 N: 100003.98 E: 204027.98 SSMH 2 STA 11+78.44 N: 100175.80 E: 204076.13 SSMH 3 STA 12+45.10 N: 100223.16 E: 204123.03 268.02 LF 8" PVC @ 0.50% 178.44 LF 8" PVC @ 0.40% 66.66 LF 8" PVC @ 2.00% 111.17 LF 8" PVC @ 1.66% STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 SANITARY SEWER LINE 2 SEE SHEET SS3 SANITARY SEWER LINE 3 SEE SHEET SANITARY SEWER LINE 3-1 SEE SHEET LOT 1 LOT 3 LOT 2 LOT 2 LOT 3 LOT 9 LOT 7 LOT 8 LOT 6 LOT 5 LOT 4 LOT 1 LOT 2 LOT 1 TRACT L DU&PAE LOT 2 LOT 3 LOT 1 TRACT E DG&PAE TRACT T DUE BLOCK 1 BLOCK 4 BLOCK 6 LOT 8 LOT 10 LOT 5 LOT 4 LOT 10 LOT 9 LOT 7 LOT 9 LOT 12 LOT 13 LOT 10 LOT 11 TRACT M PROPOSED 8" PVC WATER MISTY MEADOW DR ZEPHYR RD RED WILLOW DRIVE 4925 4930 4935 4940 4945 4950 4955 4960 4965 4925 4930 4935 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 14+50 4940 4945 4950 4955 4960 4965 4970 4975 4980 4940 4945 4950 4955 4960 4965 4970 4975 4980 14+50 15+00 16+00 17+00 18+00 19+00 20+00 20+50 EX. SSMH 1 STA 10+00.00 RIM 4955.3± INV. IN 4932.80 (N) INV. OUT 4932.36 (S) 178.44 LF 8" PVC @ 0.40% SSMH 2 STA 11+78.44 RIM 4954.4± INV. IN 4940.13 (NE) INV. IN 4933.71 (NW) INV. OUT 4933.51 (S) 66.66 LF 8" PVC @ 2.00% SSMH 3 STA 12+45.10 RIM 4954.4± INV. IN 4941.66 (NE) INV. IN 4941.76 (SE) INV. OUT 4941.46 (SW) 111.17 LF 8" PVC @ 1.66% SSMH 4 STA 13+56.27 RIM 4956.4± INV. IN 4943.81 (NW) INV. OUT 4943.51 (SW) 268.02 LF 8" PVC @ 0.50% SSMH 5 STA 16+24.28 RIM 4960.5± INV. IN 4945.35 (NW) INV. OUT 4945.15 (SE) 297.44 LF 8" PVC @ 0.40% SSMH 6 STA 19+21.72 RIM 4966.0± INV. IN 4946.64 (NW) INV. OUT 4946.54 (SE) EXISTING GROUND PROPOSED GROUND EXISTING GROUND PROPOSED GROUND 15" RCP STORM STA.=11+93.06 INV.=4949.21 15" RCP STORM STA.=12+35.02 INV.=4948.89 E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E G G G G G G E E E E G G G UD UD UD UD UD E E G w W S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W VAULT VAULT VAULT VAULT E E E VAULT F.O. FO FO FO FO FO FO FO FO FO FO FO E T T T T T T T T T SSMH 6 STA 19+21.72 N: 100739.50 E: 203856.50 SSMH 5 STA 16+24.28 N: 100540.75 E: 204077.78 268.02 LF 8" PVC @ 0.50% 297.44 LF 8" PVC @ 0.40% STORM DRAIN 2 LOT 2 LOT 15 LOT 14 LOT 1 LOT 2 LOT 3 LOT 10 LOT 11 LOT 9 LOT 3 LOT 4 LOT 3 LOT 1 LOT 15 LOT 14 LOT 13 LOT 12 LOT 11 LOT 1 LOT 2 TRACT C FUTURE PUBLIC PARK PEDESTRIAN ACCESS EASEMENT TRACT D DUA&EAE BLOCK 4 SANITARY SEWER LINE 2-2 SEE SHEET SS5 SANITARY SEWER LINE 2-4 SEE SHEET SS6 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 5' TRAIL STORM DRAIN 1 SEE SHEET ST1 TRACT J PROPOSED 8" PVC WATER SANITARY SEWER LINE 2-5 FLYING MALLARD DR WINDY WILLOW DR MISTY MEADOW DR DITCH LATERAL MISTY MEADOW DR SANITARY SEWER LINE 1 NORTH PROFILE SCALE: Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING WATER MAIN PROPOSED WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL SANITARY CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7. ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. W EXISTING STORM SEWER PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY PROPOSED WATER SERVICE W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED SUBDRAIN SD B M KEYMAP SS1 PLAN AND PROFILE SANITARY SEWER LINE 1 9 LINE MATCH STA 14+50 LINE MATCH STA 14+50 NORTH LINE MATCH STA 20+50 MATCH LINE SEE SHEET SS2 STA 20+50 SS1 SS2 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R FO FO FO FO FO FO FO FO FO FO E E E T T T T T T T T T T T T T T T T T T T T T T G G G G G G G G G G G G T T T T T T T W W W W W W W W W W W W W W W T E E 12" W 12" W X X SS SS V AULT ELEC X X X X X X X X X X X X X X X X X X IRR IRR E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E G G G G E E E E E E E E G G G G G UD UD UD UD UD G G G G E E E E E E G G w W S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W S w W w W w W V AULT VAULT VAULT VAULT VAULT VAULT VAULT E E E E VAULT VAULT WINDY WILLOW DR ZEPHYR RD MISTY MEADOW DR PROPOSED PEDESTRIAN BRIDGE PLANNED TEMP. FH ASSEMBLY AND REDUCER 9' UTILITY EASEMENT 9' UTILITY EASEMENT 6' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 53' ROW 57' ROW 76' ROW 54' FL-FL 36' FL-FL 30' FL-FL LOT 9 LOT 6 LOT 7 LOT 4 LOT 5 LOT 4 LOT 3 LOT 15 LOT 14 LOT 13 LOT 12 LOT 16 LOT 22 LOT 21 LOT 20 LOT 19 LOT 18 LOT 17 LOT 3 LOT 15 LOT 14 LOT 12 LOT 13 LOT 10 LOT 11 LOT 9 LOT 7 LOT 5 LOT 4 LOT 1 LOT 2 LOT 10 LOT 11 LOT 2 TRACT T DUE TRACT O FUTURE DEVELOPMEMT TRACT J BLOCK 16 BLOCK 5 BLOCK 4 BLOCK 1 EXISTING 10" PVC SANITARY SSMH 6 SSMH 5 SSMH 2-2C SSMH 4 EX. SSMH 1 SSMH 2-2B SSMH 3 SSMH 2 SSMH 2-1 SSMH 2-2 SSMH 2-3 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 6 SSMH 3-1 SSMH 3-2 SSMH 3-3 15' EASEMENT REC. NO. 20140004033 30' EASEMENT REC. NO. 20140004033 15' EASEMENT REC. NO. 20110070565 15' EASEMENT REC. NO. 20140004033 PLANNED 20' GRAVEL ROAD TO REMAIN PLANNED 30' SFCSD EASEMENT EXISTING 10" PVC SANITARY DITCH LATERAL PLANNED HANSEN FARM ZEPHYR RD (PLANNED) ROSEN DRIVE RED WILLOW DRIVE DETENTION POND 1 PROPOSED 8" WATER STUB TRACT M 5' TRAIL 5' TRAIL 5' TRAIL TRACT E DGE 5' WALK 6' UTILITY EASEMENT 5' UTILITY EASEMENT SSMH 3-1C 8" PVC SANITARY SSMH 3-1B SSMH 3-1A SSMH 3-3A LOT 1 LOT 8 LOT 10 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 10 LOT 9 LOT 7 LOT 1 LOT 2 LOT 3 LOT 4 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 TRACT L DU&PAE TRACT N DU&PAE BLOCK 2 BLOCK 3 BLOCK 3 BLOCK 2 TRACT C FUTURE PUBLIC PARK LOT 3 LOT 2 LOT 3 SSMH 3-4 EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK LOT 1 LOT 2 LOT 1 249.04 LF 8" PVC S27°18'59"E 10.00 LF 8" PVC S16°41'01"W 73.75 LF 8" PVC N00°06'45"E 148.48 LF 8" PVC N22°36'45"E 9.08 LF 8" PVC N45°06'45"E 17.34 LF 8" PVC N50°26'01"E FH ASSEMBLY N:100566.38 E:204019.81 FH ASSEMBLY N:100256.23 E:204097.19 FH ASSEMBLY N:100013.66 E:204192.84 STREET LIGHT N:100668.67 E:203906.53 STREET LIGHT N:100575.86 E:204009.53 STREET LIGHT N:100499.97 E:204118.79 STREET LIGHT N:100309.66 E:204156.61 STREET LIGHT N:100291.51 E:204243.77 STREET LIGHT N:100382.86 E:204386.02 STREET LIGHT N:100322.45 E:204576.78 STREET LIGHT N:100061.34 E:204004.38 STREET LIGHT N:100163.99 E:204104.25 STREET LIGHT N:100247.94 E:203873.12 STREET LIGHT N:100508.76 E:203926.72 22.5° BEND N:100534.54 E:204069.74 45° BEND N:100313.27 E:204184.03 22.5° BEND N:100303.69 E:204181.15 11.25° BEND N:100300.98 22.5° BEND E:204178.94 N:100208.66 E:204076.66 22.5° BEND N:100071.59 E:204019.56 22.5° BEND N:100453.35 E:203860.03 11.25° BEND N:100542.53 E:203914.22 FH ASSEMBLY N:100212.27 E:204579.31 FH ASSEMBLY 1 - 6" GV N:100077.52 E:204501.86 8" x 6" SWIVEL TEE 1 - 6" GV (S) N:100573.58 E:204026.27 8" x 6" SWIVEL TEE 1 - 6" GV (NW) N:100242.91 E:204111.99 8" x 8" TEE w/ TB 2 - 8" GV (S, W) N:100615.42 E:203979.69 45° BEND N:100063.47 E:204184.86 45° BEND N:100077.61 E:204199.00 22.5° BEND N:100221.33 E:204340.77 22.5° BEND N:100197.02 E:204272.15 45° BEND N:100153.84 E:204217.50 8" x 6" SWIVEL TEE 1 - 6" GV (S) 1 - 8" GV (E) N:100222.48 E:204579.26 8" x 8" TEE w/ TB 2 - 8" GV (E, W) N:100221.45 E:204366.90 LOT 8 8" x 8" TEE w/ TB 2 - 8" GV (N, W) N:100077.60 E:204217.48 8" x 6" SWIVEL TEE 1 - 6" GV (E) N:100013.66 E:204184.84 8" x 12" WET TAP CONNECTION 1 - 8" GV (N) N:99961.12 E:204184.83 8" x 12" WET TAP CONNECTION 1 - 8" GV (N) N:99962.43 E:204366.83 8" CROSS 3 - 8" GV (N, E, W) 1 - 8"X6" REDUCER (E) N:100077.56 E:204366.86 187.05 LF 8" PVC N00°00'00"E 101.30 LF 8" PVC N10°19'19"E 104.36 LF 8" PVC N31°17'11"E 97.97 LF 8" PVC N41°55'45"E STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 STORM DRAIN 1 SEE SHEET ST1 STORM DRAIN 2 SEE SHEET ST2 N:100307.11 E:204829.50 SANITARY SEWER LINE 1 SEE SHEET SS1 SANITARY SEWER LINE 2-4 SEE SHEET SS6 SANITARY SEWER LINE 2 SEE SHEET SS3 SANITARY SEWER LINE 3 SEE SHEET SS8 SANITARY SEWER LINE 3-3 SEE SHEET SS9 SANITARY SEWER LINE 3-1 SEE SHEET SS9 66.44 LF 8" PVC BEGIN HORZ. DEFLECTION N:100289.93 E:204165.58 END HORZ. DEFLECTION N:100215.06 E:204083.09 40.14 LF 8" PVC R=1200.00' 7 1 . 30 L F 8 " PV C R = 1 2 00 . 00 ' TIE TO EXISTING WATERLINE STUB N:99997.84 E:204019.42 69.65 LF 8" PVC N51°41'05"E 76.23 LF 8" PVC N00°01'02"E 149.38 LF 8" PVC S89°58'58"E 20.00 LF 8" PVC N45°01'02"E 49.81 LF 8" PVC N00°01'04"E 52.54 LF 8" PVC N00°01'00"E SIGHT DISTANCE EASEMENT 72.80 LF 8" PVC N70°29'38"E 26.14 LF 8" PVC N89°43'21"E 212.36 LF 8" PVC N89°43'21"E 135.00 LF 6" PVC S89°58'58"E 115.13 LF 8" PVC N00°01'02"E 143.89 LF 8" PVC N00°01'02"E 18.48 LF 8" PVC S89°58'58"E Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 U3 UTILITY PLAN 8 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 2. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND WATER LINES. 4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM COVER SHALL BE 6.0 FEET. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN BICYCLE OR VEHICLE WHEEL PATHS. 6. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8. ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS. 9. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 10. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. 11. CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 12. ALL IMPROVEMENTS LABELED AS "PLANNED" ARE A PART OF THE HANSEN PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE FOUND IN THE HANSEN FARM UTILITY PLANS. 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES NORTH B M KEYMAP MATCHLINE-SEE SHEET U2 U1 U1 U2 U3 E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G UD UD UD UD E E E E E E G G G G S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w w W w W w W w W w W w W w W w W w w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W UD UD UD w W VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT E E E E E E E E VAULT E E E E E E E E E E E E E VAULT DANCING CATTAIL DR CROAKING TOAD DR FLYING MALLARD DR WINDY WILLOW DR MISTY MEADOW DR AUTUMN BREEZE CT 9' UTILITY EASEMENT 6' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 6' UTILITY EASEMENT 53' ROW 53' ROW 53' ROW 30' FL-FL 30' FL-FL 30' FL-FL LOT 8 LOT 9 LOT 12 LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 1 LOT 2 LOT 3 LOT 12 LOT 13 LOT 10 LOT 11 LOT 1 LOT 2 LOT 5 LOT 6 LOT 7 LOT 15* LOT 11 LOT 9* LOT 10* LOT 12* LOT 13* LOT 14* LOT 17* LOT 16* LOT 3 LOT 6 LOT 7 LOT 82 LOT 5 LOT 4 LOT 1 LOT 2 LOT 8 LOT 10 LOT 11 LOT 15 LOT 14 LOT 1 LOT 2 LOT 4 LOT 3 LOT 5 LOT 9 LOT 6 LOT 7 LOT 8 LOT 12 LOT 10 LOT 11 LOT 13 LOT 3 LOT 6 LOT 5 LOT 4 LOT 2 LOT 10 LOT 7 LOT 11 LOT 7* LOT 6* TRACT S DUA TRACT D DUA&EAE LOT 1 LOT 4 LOT 8* LOT 9 LOT 12* LOT 6* LOT 10* LOT 9* LOT 8* LOT 7* LOT 5* LOT 4* LOT 3* LOT 2* LOT 1* LOT 14* LOT 2* LOT 10* LOT 9* LOT 8* LOT 2* LOT 3* LOT 1* LOT 5* LOT 4* LOT 3* LOT 1* LOT 4* LOT 9* LOT 8* LOT 7* LOT 6* LOT 5* TRACT F TRACT P TRACT Q TRACT G TRACT S DUA TRACT D DUA&EAE TRACT I TRACT H BLOCK 9 BLOCK 13 BLOCK 14 BLOCK 15 BLOCK 16 BLOCK 13 BLOCK 14 BLOCK 8 BLOCK 8 BLOCK 7 BLOCK 15 BLOCK 16 SSMH 6 SSMH 7 SSMH 2-4C SSMH 2-5D SSMH 2-4B SSMH 2-5C SSMH 2-2A SSMH 2-2 SSMH 2-4A SSMH 2-3 SSMH 2-4 SSMH 2-6B SSMH 2-5 SSMH 2-6A SSMH 2-6 SSMH 2-5B SSMH 2-5A SSMH 2-7 SSMH 2-8 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 8" PVC SANITARY 9' UTILITY EASEMENT 20' 20' 20' 20' 8' UTILITY EASEMENT 6' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 5' UTILITY EASEMENT 5' UTILITY EASEMENT TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT DETENTION POND EDGE OF WETLAND PROPOSED FOREBAY PROPOSED FOREBAY 5' TRAIL 5' TRAIL 5' TRAIL 5' TRAIL 5' TRAIL 5' TRAIL WETLAND BUFFER (TYP.) 5' TRAIL WATER QUALITY POND 1 WATER QUALITY POND 2 RAIN GARDEN 1 LOT 8* LOT 7 LOT 3 LOT 4 LOT 5 LOT 11* LOT 10* LOT 9* LOT 6 BLOCK 6 6' UTILITY EASEMENT FUTURE STORM DRAIN (BY OTHERS) FUTURE STORM OUTFALL FOR PROPERTY TO SOUTH (BY OTHERS) NATURAL HABITAT BUFFER ZONE WETLAND BUFFER LOT 13* LOT 11* FH ASSEMBLY N:100891.18 E:203658.88 STREET LIGHT N:100898.24 E:203650.71 STREET LIGHT N:100791.16 E:203827.70 STREET LIGHT N:100160.90 E:203754.07 STREET LIGHT N:100122.73 E:203636.38 STREET LIGHT N:100122.49 E:203505.52 STREET LIGHT N:100161.14 E:203332.07 STREET LIGHT N:100123.16 E:203183.55 STREET LIGHT N:100161.60 E:203021.98 STREET LIGHT N:100122.76 E:202853.37 STREET LIGHT N:100303.53 E:203135.97 STREET LIGHT N:100338.07 E:203389.37 STREET LIGHT N:100508.60 E:203365.04 STREET LIGHT N:100650.69 E:203449.85 STREET LIGHT N:100816.13 E:203502.80 STREET LIGHT N:100704.39 E:203720.54 STREET LIGHT N:100558.84 E:203674.88 STREET LIGHT N:100440.36 E:203595.62 STREET LIGHT N:100298.31 E:203631.83 FH ASSEMBLY N:100161.14 E:203810.37 LOT 12 11.25° BEND N:100695.88 E:203728.02 22.5° BEND N:100541.73 E:203633.75 22.5° BEND N:100364.05 E:203600.87 11.25° BEND N:100541.87 E:203381.71 11.25° BEND N:100710.03 E:203446.14 45° BEND N:100166.64 E:203841.87 45° BEND N:100151.93 E:203827.17 11.25° BEND N:100353.69 E:203841.87 22.5° BEND N:100453.35 E:203860.03 FH ASSEMBLY N:100161.16 E:203411.37 FH ASSEMBLY 1 - 6" GV (SE) 1 - 8" x 6" REDUCER (SE) N:100228.24 E:202793.08 FH ASSEMBLY 1 - 6" GV (SW) 1 - 8" x 6" REDUCER (SW) N:100277.11 E:203149.11 FH ASSEMBLY N:100601.66 E:203389.65 FH ASSEMBLY N:100515.46 E:203612.57 107.86 LF 8" PVC S44°59'52"E 8" x 6" SWIVEL TEE 1 - 6" GV (S) N:100898.03 E:203665.03 LOT 3 8" x 6" SWIVEL TEE 1 - 6" GV (W) 1 - 8" GV (S) N:100596.66 E:203402.70 8" x 6" SWIVEL TEE 1 - 6" GV (N) N:100151.95 E:203411.37 8" x 6" SWIVEL TEE 1 - 6" GV (W) 1 - 8" GV (S) N:100512.52 E:203628.34 8" x 8" TEE w/ TB 2 - 8" GV (E, W) N:100151.94 E:203600.87 8" x 8" TEE w/ TB 3 - 8" GV (E, S, W) N:100151.95 E:203359.87 TEMP. FH ASSEMBLY N:100005.52 E:203359.87 8" x 8" TEE w/ TB 2 - 8" GV (N, W) N:100151.96 E:203070.84 45° BEND N:100151.97 E:202869.34 45° BEND N:100198.83 E:203070.84 8" x 8" TEE w/ TB 2 - 8" GV (S, W) N:100937.50 E:203621.09 8" x 8" TEE w/ TB 2 - 8" GV (SW, NW) N:100776.46 E:203800.39 8" x 6" SWIVEL TEE 1 - 6" GV (N) 1 - 8" GV (E) N:100151.93 E:203810.37 20.80 LF 8" PVC N45°00'08"E 187.05 LF 8" PVC N00°00'00"E 101.30 LF 8" PVC N10°19'19"E 104.36 LF 8" PVC N31°17'11"E 108.30 LF 8" PVC S41°55'45"W 180.70 LF 8" PVC S31°26'48"W 212.11 LF 8" PVC S00°00'00"W 107.82 LF 8" PVC S41°55'45"W 54.82 LF 8" PVC S36°55'45"W 26.17 LF 8" PVC S32°12'52"W 26.17 LF 8" PVC S09°42'52"W 54.82 LF 8" PVC S05°00'00"W 358.12 LF 8" PVC S00°00'00"W 98. 7 4 L F 8 " P V C R = 12 0 0 . 0 0 ' 98.7 4 L F 8 " P V C R = 12 00.0 0 ' BEGIN HORZ. DEFLECTION N:100516.08 E:203377.29 END HORZ. DEFLECTION N:100418.18 E:203364.65 46.87 LF 8" PVC N00°00'14"W 110.70 LF 8" PVC N44°59'46"E BEGIN HORZ. DEFLECTION N:100813.46 E:203516.10 END HORZ. DEFLECTION N:100732.18 E:203460.09 STORM DRAIN 4 SEE SHEET ST3 STORM DRAIN 1 SEE SHEET ST1 STORM DRAIN 5 SEE SHEET ST4 STORM DRAIN 6 SEE SHEET ST4 SANITARY SEWER LINE 2-5 SEE SHEET SS7 SANITARY SEWER LINE 2-4 SEE SHEET SS6 SANITARY SEWER LINE 2-6 SEE SHEET SS8 SANITARY SEWER LINE 2 SEE SHEET SS4 5° HIGH DEFLECTION COUPLING N:100857.28 E:203549.04 5° HIGH DEFLECTION COUPLING N:100363.57 E:203359.87 121.41 LF 8" PVC S20°57'52"W 58.67 LF 8" PVC S20°57'52"W 201.50 LF 8" PVC S89°59'52"E 16.80 LF 8" PVC S89°59'52"E 209.50 LF 8" PVC S89°59'52"E 189.50 LF 8" PVC S89°59'52"E 340.53 LF 8" PVC S89°59'52"E PROPOSED AIR VAC N:100732.06 E:203849.82 66.44 LF 8" PVC N48°04'15"W 181.94 LF 8" PVC N48°04'15"W 59.06 LF 8" PVC N48°04'15"W 29.70 LF 8" PVC S10°28'56"W 151.00 LF 8" PVC S10°28'56"W TIE TO EXISTING WATERLINE STUB STORM DRAIN 8 SEE SHEET ST5 4' CURB CUT AND SIDEWALK CULVERT 4' CURB CUT AND SIDEWALK CULVERT 4' CURB CUT 340.53 LF 8" PVC S89°59'52"E 4' CURB CUT AND SIDEWALK CULVERT ALLEY 1 ALLEY 2 DETENTION POND DEPTH GAUGE Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 U2 UTILITY PLAN 7 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 2. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND WATER LINES. 4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM COVER SHALL BE 6.0 FEET. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN BICYCLE OR VEHICLE WHEEL PATHS. 6. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8. ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS. 9. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 10. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. 11. CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 12. ALL IMPROVEMENTS LABELED AS "PLANNED" ARE A PART OF THE HANSEN PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE FOUND IN THE HANSEN FARM UTILITY PLANS. 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES NORTH B M KEYMAP MATCHLINE-SEE SHEET U1 MATCHLINE-SEE SHEET U3 U1 U1 U2 U3 FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E E E E W M WM WM WM WM WM WM WM WM WM WM W WM M WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM UD E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E G G G G G G G G G G G UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w w W UD UD UD UD UD UD UD UD UD UD UD UD S w W S w W w W w W w W VAULT E VAULT VAULT VAULT VAULT E E E E E E E E MISTY MEADOW DR FALLEN BRANCH DR PLANNED PEDESTRIAN BRIDGE (SEE HANSEN FARM UTILITY PLANS) 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 6' UTILITY EASEMENT 30' FL-FL 53' ROW 59' ROW 36' FL-FL LOT 6 LOT 8 LOT 7 LOT 3 LOT 5 LOT 4 LOT 1 LOT 2 LOT 3 LOT 8 LOT 6 LOT 5 LOT 7 LOT 12 LOT 17 LOT 16 LOT 15 LOT 14 LOT 13 LOT 11 LOT 9 LOT 16 LOT 15 LOT 13 LOT 14 LOT 12 LOT 11 LOT 9 LOT 10 LOT 8 LOT 7 LOT 5 LOT 4 LOT 6 LOT 3 LOT 4 BLOCK 11 BLOCK 10 BLOCK 12 BLOCK 10 PLANNED 8" PVC WATER EXISTING 8" PVC SANITARY SSMH 8 SSMH 9 SSMH 10 SSMH 11 8" PVC SANITARY 8" PVC SANITARY 30' EASEMENT REC. NO. 20110070565 67' EASEMENT REC. NO. 20140004033 TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT DITCH LATERAL 15' EASEMENT REC. NO. 20110070565 EXISTING ANTENNA DITCH LATERAL 30' EASEMENT REC. NO. 20140004033 PLANNED HANSEN FARM PLANNED HANSEN FARM 30' EASEMENT REC. NO. 20140004033 15' EASEMENT REC. NO. 20110070565 BLOCK 10 5' TRAIL 5' TRAIL 5' TRAIL TRACT U D&PAE 5' TRAIL 5' TRAIL WETLAND BUFFER (TYP.) 6' UTILITY EASEMENT 5' UTILITY EASEMENT 6' UTILITY EASEMENT PROPOSED GRASS-LINED SWALE EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE LOT 1 LOT 2 389.04 LF 8" PVC S62°23'40"E FH ASSEMBLY N:101235.69 E:203275.31 FH ASSEMBLY 1 - 6" GV (E) 1 - 8" x 6" REDUCER (E) N:101544.76 E:202803.42 STREET LIGHT N:101448.75 E:202805.02 STREET LIGHT N:101469.38 E:203000.17 STREET LIGHT N:101340.59 E:203154.11 STREET LIGHT N:101247.51 E:203320.06 STREET LIGHT N:101115.17 E:203409.42 STREET LIGHT N:101025.41 E:203566.70 22.5° BEND N:101533.70 E:202813.25 11.25° BEND N:101353.43 E:203158.00 8" x 6" SWIVEL TEE 1 - 6" GV (SW) N:101242.54 E:203281.47 LOT 10 8" x 8" TEE w/ TB 2 - 8" (NE, NW) N:101205.12 E:203323.12 45° BEND N:101328.11 E:203437.00 45° BEND CONNECT TO EXISTING 8" PVC N:101384.64 E:203434.82 56.57 LF 8" PVC S02°12'15"E STORM DRAIN 7 SEE SHEET ST5 PROPOSED AIR VAC N:101305.29 E:203415.87 SANITARY SEWER LINE 1 SEE SHEET SS2 SUBDRAIN LINE 1-4 SEE SHEET SD2 SUBDRAIN LINE 1-4 SEE SHEET SD2 SUBDRAIN LINE 1-4 SEE SHEET SD2 55.99 LF 8" PVC N48°04'15"W 165.96 LF 8" PVC N48°04'15"W 136.52 LF 8" PVC S42°47'45"W 31.09 LF 8" PVC S42°47'45"W 400.51 LF 8" PVC N48°04'15"W 14.80 LF 8" PVC N41°38'04"W Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 U1 UTILITY PLAN 6 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 2. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND WATER LINES. 4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM COVER SHALL BE 6.0 FEET. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN BICYCLE OR VEHICLE WHEEL PATHS. 6. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8. ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS. 9. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 10. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. 11. CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 12. ALL IMPROVEMENTS LABELED AS "PLANNED" ARE A PART OF THE HANSEN PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE FOUND IN THE HANSEN FARM UTILITY PLANS. 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES NORTH B M KEYMAP MATCHLINE-THIS SHEET MATCHLINE-THIS SHEET MATCHLINE-SEE SHEET U2 U1 U1 U2 U3 G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E G G G G G G G G G G E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G E E E G G UD UD UD UD UD UD UD UD UD UD UD UD G G E E E G G w W S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W S w W w W w W UD UD UD UD UD UD w W S w W S w W w W w W w W w W w W w W w W UD w W w W w W VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT E VAULT VAULT VAULT VAULT 12" W 12" W X SS VAULT ELEC X X X X X IRR WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM UD UD UD VAULT TELE T VAULT TELE W S O H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC H Y D S S S ELEC E ELEC BRKR X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS SS SS SS SS LID VAULT F.O. W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E T T T T T T T T T T T G G G G G G T T T W W W W W W W MISTY MEADOW DR DANCING CATTAIL DR CROAKING TOAD DR FLYING MALLARD DR WINDY WILLOW DR MISTY MEADOW DR ZEPHYR RD FALLEN BRANCH DR AUTUMN BREEZE CT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT DITCH LATERAL PROPOSED PEDESTRIAN BRIDGE PLANNED PEDESTRIAN BRIDGE (SEE HANSEN FARM UTILITY PLANS) UNION-PACIFIC RAILROAD BLOCK 1 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 13 BLOCK 14 BLOCK 15 BLOCK 16 BLOCK 5 BLOCK 12 BLOCK 10 BLOCK 11 TRACT S DUA TRACT D DUA&EAE TRACT M TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT TRACT I TRACT H TRACT J TRACT F TRACT P TRACT Q TRACT G TRACT C FUTURE PUBLIC PARK PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED PROPOSED FIRE HYDRANT FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED TEMP. FIRE HYDRANT PLANNED HANSEN FARM KNOBBY PINE DR FALLEN BRANCH DR FLOATING LEAF DR KNOBBY PINE DR TIE TO EXISTING 8" WATERLINE PLANNED HANSEN FARM DETENTION POND PROPOSED 8" WATER STUB TIE TO EXISTING 8" WATERLINE TIE TO EXISTING 12" WATERLINE TIE TO EXISTING 8" SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED STORM DRAIN DETENTION POND 1 RED WILLOW DRIVE TRACT E DGE TRACT N DU&PAE TRACT U D&PAE BLOCK 2 BLOCK 3 TRACT T DUE PROPOSED FIRE HYDRANT FUTURE STORM OUTFALL FOR PROPERTY TO SOUTH (BY OTHERS) BLOCK 6 50' DITCH BUFFER FROM TOP OF BANK 50' DITCH BUFFER FROM TOP OF BANK EXISTING TOP OF DITCH BANK EXISTING TOP OF DITCH BANK NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE FUTURE STORM DRAIN (BY OTHERS) WETLAND BUFFER NATURAL HABITAT BUFFER ZONE STORM DRAIN 7 SEE SHEET ST5 SUBDRAIN LINE 1-4 SEE SHEET SD2 SANITARY SEWER LINE 1 SEE SHEET SS2 SANITARY SEWER LINE 1 SEE SHEET SS1 SANITARY SEWER LINE 2-5 SEE SHEET SS7 SANITARY SEWER LINE 2-4 SEE SHEET SS6 SANITARY SEWER LINE 2-4 SEE SHEET SS6 SANITARY SEWER LINE 2-6 SEE SHEET SS8 SANITARY SEWER LINE 2 SEE SHEET SS4 SANITARY SEWER LINE 2 SEE SHEET SS3 SANITARY SEWER LINE 3 SEE SHEET SS8 SANITARY SEWER LINE 3-3 SEE SHEET SS9 SANITARY SEWER LINE 3-1 SEE SHEET SS9 STORM DRAIN 2 SEE SHEET ST2 STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 1 SEE SHEET ST1 STORM DRAIN 4 SEE SHEET ST3 STORM DRAIN 5 SEE SHEET ST4 STORM DRAIN 6 SEE SHEET ST4 SUBDRAIN LINE 1 SEE SHEET SD1 SUBDRAIN LINE 1 SEE SHEET SD1 ALLEY 1 ALLEY 2 STORM DRAIN 8 SEE SHEET ST5 X X X X X X X DITCH LATERAL UNION PACIFIC RAILROAD PROPERTY BOUNDARY (TYP.) MAIL CREEK DITCH KNOBBY PINE DR FUTURE PEDESTRIAN BRIDGE PLANNED HANSEN FARM EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK 200' PUBLIC ACCESS AND TRAIL EASEMENT 66' MAIL CREEK DITCH EASEMENT Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 OU1 UTILITY PLAN OVERALL 5 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 2. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE DATE OF CONSTRUCTION. 3. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND WATER LINES. 4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM COVER SHALL BE 6.0 FEET. 5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN BICYCLE OR VEHICLE WHEEL PATHS. 6. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 8. ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS. 9. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 10. ALL LOTS MARKED WITH AN ASTERISKS (*). SEWAGE EJECTOR PUMPS ARE ANTICIPATED FOR BASEMENTS. 11. CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 12. ALL IMPROVEMENTS LABELED AS "PLANNED" ARE A PART OF THE HANSEN PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE FOUND IN THE HANSEN FARM UTILITY PLANS. 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES NORTH B M KEYMAP MATCHLINE-THIS SHEET MATCHLINE-THIS SHEET SS SS SS SS LID VAULT F.O. W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E T T T T T T T T T T T G G G G G G T T T W W W W W W W 12" W 12" W X SS V AULT ELEC X X X X X IRR WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM UD UD UD EXISTING WETLANDS UNION PACIFIC RAILROAD PHASE 2 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E G G G G G G G G G G E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G E E E G G UD UD UD UD UD UD UD UD UD UD UD UD G G E E E G G w W S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W w W S w W w W w W UD UD UD UD UD UD w W S w W S w W w W w W w W w W w W w W w W UD w W w W w W VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT VAULT E VAULT VAULT VAULT VAULT SANITARY SEWER MANHOLE (PHASE 1) PROPOSED STORM DRAIN (PHASE 1) WATER QUALITY POND 1 (PHASE 2) WATER QUALITY POND 2 (PHASE 2) RAIN GARDEN 1 (PHASE 1) PROPOSED DETENTION POND (PHASE 1) OUTLET STRUCTURE AND STORM PIPE (PHASE 1) FUTURE STORM DRAIN (TO BE DESIGNED AND BUILT WITH SOUTHERN PROPERTY) SANITARY SEWER MANHOLE (PHASE 1) WATER (PHASE 2) WATER (PHASE 2) WATER (PHASE 2) PLANNED PED BRIDGE (SEE HANSEN FARM UTILITY PLANS) PROPOSED PEDESTRIAN BRIDGE (PHASE 1) MISTY MEADOW DR DANCING CATTAIL DR CROAKING TOAD DR FLYING MALLARD DR WINDY WILLOW DR ZEPHYR RD FALLEN BRANCH DR AUTUMN BREEZE CT RED WILLOW DRIVE PHASE 1 PROPOSED FENCING (PHASE 1) STORM DRAIN (PHASE 2) PROPOSED STORM DRAIN (PHASE 1) PROPOSED STORM DRAIN (PHASE 1) PROPOSED STORM DRAIN (PHASE 1) SANITARY SEWER MANHOLE (PHASE 1) SANITARY SEWER MANHOLE (PHASE 1) WATER CONNECTION (PHASE 1) X X X X X X X FUTURE BRIDGE (BY OTHERS) PHASE 1 NORTH NOTES: LEGEND: PROPOSED SEWER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER PROJECT BOUNDARY PHASE LINE PH1 PHASING PLAN 4 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 MATCHLINE-THIS SHEET MATCHLINE-THIS SHEET Y D H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC H Y D S S S ELEC E ELEC BRKR OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS SS SS SS SS LID VAULT F.O. W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E T T T T T T T T T T T G G G G G G T T T W W W W W W W PLANNED TEMP. FH ASSEMBLY TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING WALL TO BE REMOVED EXISTING F/O TO REMAIN EXISTING ELECTRIC TO REMAIN 15' EASEMENT REC. NO. 20140004033 30' EASEMENT REC. NO. 20140004033 EXISTING FENCE TO BE REMOVED 15' EASEMENT REC. NO. 20110070565 EXISTING TELEPHONE LINE TO REMAIN EXISTING FENCE TO BE REMOVED EXISTING FENCE TO REMAIN EXISTING ELECTRIC BREAKER TO REMAIN 30' EASEMENT REC. NO. 20110070565 67' EASEMENT REC. NO. 20140004033 EXISTING FENCE TO REMAIN 60' EASEMENT REC. NO. 20100010642 15' EASEMENT REC. NO. 20110070565 EXISTING 24" CMP STORM TO BE REMOVED PLANNED FIRE HYDRANT TO REMAIN EXISTING SANITARY MANHOLE TO REMAIN EXISTING 12" PVC SANITARY EXISTING FIRE HYDRANT TO REMAIN EXISTING 12" PVC WATER EDGE OF WETLAND EXISTING GRAVEL ROAD TO BE REMOVED PLANNED 8" PVC WATER 50' DITCH BUFFER FROM TOP OF BANK PLANNED 10" PVC SANITARY PLANNED 20' GRAVEL ROAD TO REMAIN PLANNED 30' SFCSD EASEMENT PLANNED TEMP. FIRE HYDRANT TO REMAIN PLANNED HANSEN FARM PLANNED 24"x36" RCBC BURLEY TREE DR KNOBBY PINE DR FALLEN BRANCH DR FLOATING LEAF DR ROSEN DRIVE DITCH LATERAL 59' ROW 36' FL-FL PLANNED PEDESTRIAN BRIDGE (SEE HANSEN FARM UTILITY PLANS) 50' DITCH BUFFER FROM TOP OF BANK 54' FL-FL 76' ROW PLANNED END OF ROAD SIGNS TO BE REMOVED PLANNED HANSEN FARM EXISTING TEMPORARY FIRE HYDRANT TO BE REMOVED 15' EASEMENT REC. NO. 20140004033 EXISTING OVERHEAD ELECTRIC TO BE UNDERGROUND OR REMOVED PER UTILITY PROVIDER UNION PACIFIC RAILROAD EXISTING EDGE OF WATER AT TIME OF SURVEY EXISTING 36" IRON PIPE TO REMAIN PROJECT BOUNDARY (TYP.) RED WILLOW DRIVE EXISTING TOP OF DITCH BANK EXISTING TOP OF DITCH BANK 100' WETLAND BUFFER EXISTING CELL TOWER SITE TO REMAIN. CONTRACTOR TO PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS FROM PUBLIC ROW. EXISTING CONCRETE CROSS-PAN AND CURB RETURN TO BE REMOVED X X X X X X X EXISTING FENCE TO REMAIN EXISTING CONCRETE IRRIGATION STRUCTURE UNION PACIFIC RAILROAD MAIL CREEK DITCH DITCH LATERAL PROPERTY BOUNDARY (TYP.) PLANNED HANSEN FARM EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK FO FO FO FO E E E EXISTING GRAVEL ROAD TO BE REMOVED PLANNED TEMPORARY FIRE HYDRANT TO BE REMOVED PLANNED 8" WATERLINE TO REMAIN 59' ROW 36' FL-FL EXISTING FIBER OPTIC AND ELECTRIC LINES TO REMAIN 30' EASEMENT REC. NO. 20140004033 15' EASEMENT REC. NO. 20110070565 PLANNED 24"X36" RCBC AND CONCRETE HEADWALL OHU OHU OHU OHU OHU FO FO FO FO FO T T T T T 15' OPTION AND LAND LEASE AGREEMENT EASEMENT REC. NO. 20140004033 PLANNED 24"X36" RCBC AND CONCRETE HEADWALL 76' ROW 54' FL-FL EXISTING GRAVEL ROAD TO BE REMOVED EXISTING FIBER OPTIC AND ELECTRIC LINES TO REMAIN EXISTING OVERHEAD ELECTRIC TO BE UNDERGROUND OR REMOVED PER UTILITY PROVIDER PLANNED TEMPORARY CONSTRUCTION EASEMENT Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EX1 AND DEMOLITION PLAN EXISTING CONDITIONS 3 NORTH EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7. ALL IMPROVEMENTS LABELED AS "PLANNED" ARE A PART OF THE HANSEN PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE FOUND IN THE HANSEN FARM UTILITY PLANS. 8. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) APPROXIMATE LIMITS OF CONCRETE/ ASPHALT REMOVAL OR MILL & OVERLAY 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES B M KEYMAP MATCHLINE-THIS SHEET MATCHLINE-THIS SHEET CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 BENCHMARK 2-02 EAST SIDE OF TIMBERLAND ROAD, 1/2 MILE NORTH OF TRILBY ROAD, ON THE MIDDLE CONCRETE PAD TO AN ELECTRIC BOX. ELEVATION: 4964.37 BENCHMARK 16-01 SOUTH SIDE OF WILLOW SPRINGS WAY APPROX. 50 FT. WEST OF THE INTERSECTION OF WILLOW SPRINGS WAY AND TIMBERLINE ROAD ON THE SOUTHWEST CORNER OF A STORM INLET. ELEVATION: 4956.98 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.19' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE EAST LINE OF OUTLOT J, DAKOTA GLEN FIRST SUBDIVISION AS BEARING SOUTH 00° 16' 26" EAST (ASSUMED BEARING0 AND MONUMENT AS SHOWN ON PLAT. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: N/A CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping, symbols, and signs their placement shall be approved by the City of Fort Collins Traffic Engineer. The developer shall place temporary tabs, tape or flags depicting alignment and location. Contact City of Fort COllins Traffic Operations at 970-221-6630 for field review. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Final Drainage and Erosion Control Report for Rennat Subdivision dated Februaru 12, 2020 by Northern Engineering Services, Inc., shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All water and sanitary sewer construction shall be performed according to the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District standards and specifications. 2. Construction of water and sewer facilities require a precon meeting with district operations staff prior to construction. 3. Contractor shall notify district inspectors prior to starting work. 4. Contractor shall contact the sanitation district for sewer inspection 48 hours prior to connecting to existing sewer stubs. 5. All commercial domestic services require a reduced pressure backflow prevention device. 6. All water lines shall be a minimum of (5) five feet and a maximum of (6) feet below final grade. 7. All district shall only be operated by district operations staff. 8. Pipe Pressure and vacuum testing shall be witnessed by district inspectors. Waterline bacteria tests shall also be taken by district inspectors. 9. Once the system is operational and all tests have passed, contractor shall request substantial completion with a letter to the district that includes the dollar value of the water and sewer improvements listed separately. 10. As-builts shall be submitted in pdf and dwg to the district for final approval. 11. If groundwater is encountered within the depth of sewer construction, manholes must be water-proofed. 12. The size, type and location of all known underground utilities are approximate when shown on these drawings. It shall be the responsibility of the contractor to verify the existence of all underground utilities in the area of work. Before commencing new construction , the contractor shall be responsible for locating all underground utilities and shall be responsible for all unknown underground utilities. 13. All water fittings and valves are only graphically represented and are not to scale. 14. Manhole rim elevations are to be adjusted to 1 4" below finished grade. If necessary, cone sections shall be rotated to prevent lids being located within bicycle or vehicle wheel paths CS2 CONSTRUCTION NOTES GENERAL AND 2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 FROM FACE OF WALK 6.5' MIN FENCE SETBACK FROM FACE OF WALK 3' MIN FENCE SETBACK FROM CURB FLOWLINE 3' MIN FENCE SETBACK FROM EDGE OF ALLEY · ZEPHYR RD · MISTY MEADOW DR · DANCING CATTAIL DR · CROAKING TOAD DR · FALLEN BRANCH DR · AUTUMN BREEZE CT CONCRETE PAVEMNET 9' UTIL. 59' ROW ESMT. 9' UTIL. ESMT. LOCAL CONNECTOR 8' PARKING 8' PARKING 10' TRAVEL LANE 6.5' PKWY TBC-WALK 36' - 10' TRAVEL LANE 4.5' WALK 4.5' WALK 30" VERTICAL CURB & GUTTER 30" VERTICAL CURB & GUTTER 6.5' PKWY TBC-WALK · FLYING MALLARD DR · WINDY WILLOW DR · ALLEY 1 · ALLEY 2 12' TRAVEL LANE 24' - 12' TRAVEL LANE 8' UTIL. ESMT. 8' UTIL. ESMT. ALLEY (PRIVATE) CS1 COVER SHEET 1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MARCH 2020 PROJECT LOCATION VICINITY MAP NORTH I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: Northern Engineering Services, Inc. Project No. 1204-003 Date: February 19, 2019 ORIGINAL FIELD SURVEY BY: CONTACT INFORMATION PROJECT TEAM: Danny Weber, PE Northern Engineering Services, Inc. 301 North Howes Street, Sutie 100 Fort Collins, Colorado 80521 (970) 221-4158 Bob Tessely, PLS Northern Engineering Services, Inc. 301 North Howes Street, Sutie 100 Fort Collins, Colorado 80521 (970) 221-4158 CONTACT INFORMATION PROJECT TEAM: JD Padillla Post Modern Development 144 North Mason St., Suite 4 Fort Collins, Colorado 80524 (970) 407-7808 SHEET INDEX ENGINEER ING N O R T H E RN ENGINEER ING N O R T H E RN UTILITY CONTACT LIST: * UTILITY COMPANY PHONE NUMBER 1 CS1 COVER SHEET 2 CS2 GENERAL AND CONSTRUCTION NOTES 3 EX1 EXISTING CONDITIONS AND DEMOLITION PLAN 4 PH1 PHASING PLAN UTILITY SHEETS 5 OU1 OVERALL UTILITY PLAN 6-8 U1-U3 UTILITY PLAN SANITARY SHEETS 9-10 SS1-SS2 SANITARY SEWER LINE 1 PLAN AND PROFILE 11-12 SS3-SS4 SANITARY SEWER LINE 2 PLAN AND PROFILE 13 SS5 SANITARY SEWER LINE 2-2 PLAN AND PROFILE 14 SS6 SANITARY SEWER LINE 2-4 PLAN AND PROFILE 15 SS7 SANITARY SEWER LINE 2-5 PLAN AND PROFILE 16 SS8 SANITARY SEWER LINES 2-6 & 3 PLAN AND PROFILE 17 SS9 SANITARY SEWER LINES 3-1 & 3-3 PLAN AND PROFILE STORM SHEETS 18 ST1 STORM DRAIN LINE 1 PLAN AND PROFILE 19 ST2 STORM DRAIN LINE 2 PLAN AND PROFILE 20 ST3 STORM DRAIN LINES 3 & 4 PLAN AND PROFILE 21 ST4 STORM DRAIN LINES 5 & 6 PLAN AND PROFILE 22 ST5 STORM DRAIN LINE 7 & 8 PLAN AND PROFILE 23 SD1 SUBDRAIN LINE 1 PLAN AND PROFILE 24 SD2 SUBDRAIN LINE 1-4 PLAN AND PROFILE GRADING SHEETS 25 OG1 OVERALL GRADING PLAN 26-31 G1-G6 GRADING PLAN 32-33 G7-G8 DETAILED GRADING PLAN ROADWAY SHEETS 34-36 R1-R3 MISTY MEADOW DR PLAN AND PROFILE 37 R4 DANCING CATTAIL DR PLAN AND PROFILE 38 R5 DANCING CATTAIL DR & WINDY WILLOW DR PLAN AND PROFILE 39-40 R6-R7 CROAKING TOAD DR PLAN AND PROFILE 41 R8 FLYING MALLARD DR PLAN AND PROFILE 42 R9 FALLEN BRANCH DR PLAN AND PROFILE 43 R10 PRIVATE ALLEY 1 PLAN AND PROFILE 44 R11 PRIVATE ALLEY 2 PLAN AND PROFILE 45-46 R12-R13 ZEPHYR RD PLAN AND PROFILE 47 R14 ZEPHYR RD STRIPING PLAN 48 R15 SIGNAGE PLAN 49-51 INT1-INT3 INTERSECTION DETAILS 52-53 XS1-XS2 ZEPHYR ROAD CROSS SECTIONS DRAINAGE SHEETS 54 DR1 DRAINAGE EXHIBIT 55 EC1 EROSION CONTROL PLAN 56-57 EC2-EC3 EROSION CONTROL DETAILS DETAIL SHEETS 58-59 D1-D2 UTILITY DETAILS 60-62 D3-D5 DRAINAGE DETAILS 63 D6 GRADING DETAILS 64-66 D7-D9 SITE DETAILS A TRACT OF LAND LOCATED IN THE EAST HALF OF SECTION 7, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO RENNAT SUBDIVISION UTILITY PLANS FOR OWNER/APPLICANT SITE ENGINEER SURVEYOR GAS-----------------Xcel Energy-----------------------------------Stephanie Rich (970) 225-7857 ELECTRIC-------- City of Fort Collins Light & Power------- Austin Kreager (970) 224-6152 CABLE------------- Comcast--------------------------------------- Don Kapperman (970) 567-0245 TELECOM-------- CenturyLink Local Network--------------- William Johnson (970) 377-6401 WATER------------ Fort Collins-Loveland Water District---- Jay East (970) 226-3104 WASTEWATER- South Fort Collins Sanitation District--- Jay East (970) 226-3104 STORMWATER- City of Fort Collins Utilities---------------- Wes Lamarque (970) 416-2418 * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. Cathy Mathis TB Group 444 Mountain Avenue Berthoud, Colorado 80513 (970) 532-5891 PLANNER/ LANDSCAPE ARCHITECT PROJECT DATUM: NAVD88 BENCHMARK 2-02 EAST SIDE OF TIMBERLAND ROAD, 1/2 MILE NORTH OF TRILBY ROAD, ON THE MIDDLE CONCRETE PAD TO AN ELECTRIC BOX. ELEVATION: 4964.37 BENCHMARK 16-01 SOUTH SIDE OF WILLOW SPRINGS WAY APPROX. 50 FT. WEST OF THE INTERSECTION OF WILLOW SPRINGS WAY AND TIMBERLINE ROAD ON THE SOUTHWEST CORNER OF A STORM INLET. ELEVATION: 4956.98 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.19' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE EAST LINE OF OUTLOT J, DAKOTA GLEN FIRST SUBDIVISION AS BEARING SOUTH 00° 16' 26" EAST (ASSUMED BEARING0 AND MONUMENT AS SHOWN ON PLAT. PROJECT BENCHMARKS: All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66