Loading...
HomeMy WebLinkAboutWATERGLEN SOLAR ARRAY - PDP190010 - SUBMITTAL DOCUMENTS - ROUND 3 - SUPPLEMENTAL INFORMATION (2)PM1-31 355W 15 IN STRING 16 IN STRING 1 2 JB1 INVERTER 6 I1 100,000W 5 PV MODULE OPTIMIZER 3 1 2 3 4 JUNCTION BOX 4 JB2 INVERTER I2 66,600W 5 5 AC COMBINER 7 CB2 150A CB1 100A AC GEC F1-2 250A SW1 400A 8 6 MODULES REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-40 592 Adani ASM-7-PERC-355 355W 344W 9.42A 9.01A 47.9V 39.41V -0.29%/°C 15A INVERTERS REF. QTY. MAKE AND MODEL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1 1 SOLAR EDGE SE66.6KUS (480V) 480V NOT SOLIDLY GROUNDED -- 66,600W 80.0A 80.0A 1000V 98.5% I2 1 SOLAR EDGE SE100KUS (480V) 480V NOT SOLIDLY GROUNDED 250A 100,000W 120.0A 120.0A 1000V 98.5% POWER OPTIMIZERS REF. QTY. MODEL RATED INPUT POWER MAX OUTPUT CURRENT MAX INPUT ISC MAX DC VOLTAGE WEIGHTED EFFICIENCY PO1-40 296 SOLAR EDGE P730 730W 15A 11.0A 125V 98.6% DISCONNECTS REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 Cutler-Hammer DH365FRK OR EQUIV. 400A 600VAC OCPDS REF. QTY. RATED CURRENT MAX VOLTAGE CB1 1 100A 480VAC (3- Pole) CB2 1 150A 480VAC (3- Pole) F1-2 2 250A 480VAC (3- Pole) NOTES 1 OPTIMIZERS PROVIDE RAPID SHUTDOWN FUNCTIONALITY REQUIRED BY NEC 690.12. THE SPECIFIED OPTIMIZER CAN BE SUBSTITUTED WITH A P850. THIS OPTIMIZER HAS AN INPUT VOLTAGE WINDOW WIDE ENOUGH TO ACCOMMODATE THE OUTPUT VOLTAGE RANGE OF THE MODULE AT THE DESIGN TEMPERATURES, HAS A MAX INPUT CURRENT RATING THAT IS ABOVE THE MAX OUTPUT CURRENT OF THE MODULE, AND A MAX POWER INPUT THAT IS ABOVE THE RATED POWER OUTPUT OF THE MODULE. 2 DC PV CONDUCTORS ARE NOT SOLIDLY GROUNDED. NO DC PV CONDUCTOR SHALL BE WHITE- OR GRAY-COLORED 3 MAX DC VOLTAGE OF ARRAY FIXED BY THE INVERTER AT 1000V REGARDLESS OF TEMPERATURE. THE MAX DC VOLTAGE OF THE MODULE AT -23°C IS EXPECTED TO BE 48.6V (-23°C - 25°C) X -0.105V/C + 43.6V = 48.6V). 4 INVERTER IS NON-ISOLATED. NO CONDUCTOR IS SOLIDLY GROUNDED AND THEREFORE NO DC GEC IS REQUIRED. 5 6 POINT-OF-CONNECTION IS ON THE SERVICE SIDE OF SERVICE TRANSFORMER CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYIN G CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LENGTH VOLTAGE DROP 1 1 10 AWG PV WIRE, COPPER FREE AIR N/A N/A 6 AWG BARE, COPPER 0.71 (56°C) 1.0 15A 18.75A 55A 39.05A 75°C 50A 175FT 0.48% 2 1 10 AWG PV WIRE, COPPER 1.5" DIA. PVC 18 N/A 6 AWG BARE, COPPER 0.71 (56°C) 1.0 15A 18.75A 55A 39.05A 75°C 50A 70FT 0.56% 3 1 10 AWG PV WIRE, COPPER FREE AIR N/A N/A 6 AWG BARE, COPPER 0.71 (56°C) 1.0 15A 18.75A 55A 39.05A 75°C 50A 140FT 0.41% 4 1 10 AWG PV WIRE, COPPER 1.5" DIA. PVC 12 N/A 6 AWG BARE, COPPER 0.71 (56°C) 1.0 15A 18.75A 55A 39.05A 75°C 50A 60FT 0.58% 5 1 1/0 AWG THWN-2, COPPER 2" DIA. EMT 3 150A 6 AWG THWN-2, COPPER 0.76 (54°C) 1.0 120A 150A 170A 157A 75°C 170A 40FT 0.22% 6 1 3 AWG THWN-2, COPPER 1.5" DIA. EMT 3 100A 6 AWG THWN-2, COPPER 0.96 (34°C) 1.0 80A 100A 115A 110A 75°C 115A 40FT 0.27% 7 1 250 kcmil THHN, COPPER 2.5" DIA. EMT 3 250A 6 AWG THWN-2, COPPER 0.96 (34°C) 1.0 200A 250A 290A 232A 75°C 290A 5FT 0.07% 8 1 250 kcmil THHN, COPPER 2.5" DIA. EMT 3 N/A 6 AWG THWN-2, COPPER 0.96 (34°C) 1.0 200A 250A 290A 232A 75°C 290A 5FT .07% 9 1 500 kcmil DIRECT BURIAL, AL DIRECT BURIAL 3 250A 6 AWG THWN-2, COPPER 0.96 (34°C) 1.0 200A 250A 350A 280A 60°C 350A 400FT 1.5% MAIN SERVICE TRANSFORMER (N) 277/480V 3ΙΈ, 3W 300 KVA 7 8 9 KWHR PV GENERATION METER (Lever ByPass) 9 PM1-31 355W 1 3 MODULE COUNT: 224 STRING COUNT: 7 STRINGING SCHEDULE (SE100K): PRIMARY UNIT: Strings 1-3: 42 Modules (21 P730) SECONDARY UNIT 1: Strings 4-6: 42 Modules (21 P730) SECONDARY UNIT 2: · String 7: 32 Modules (16 P730) · String 8: 34 Modules (17 P730) · String 9: 36 Modules (18 P730) STRINGING SCHEDULE (SE66.6K): PRIMARY UNIT: · Strings 1: 38 Modules (19 P730) · Strings 2-3: 40 Modules (20 P730) SECONDARY UNIT 1: Strings 4-6: 40 Modules (20 P730) Solar -> Transformer Rated Voltage Drop Calculation (MAX) (0.0424 ohm/ 1000 feet)*400 feet = 0.0169 Resistance 250A x 0.0169 ohms 4.24 V Drop 4.24V / 277 V 1.5% % V Drop 277v - 4.24v 272.76V Operating V Ground Rod at Each Array INTEGRATED DC DISCONNECT IS PROVIDED WITH INVERTER. DISCONNECT IS LISTED FOR USE WITH SOLAR EDGE UL 1741 LISTED STRING INVERTERS. 7 SYSTEM SUMMARY ARRAY STC POWER 210,160W ARRAY PTC POWER 203,648W MAX AC CURRENT 200A MAX AC POWER OUTPUT 166,500W DERATED AC POWER OUTPUT 150,000W REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE: SP3 SMALL SCALE GRID-TIED PV SYSTEM FORT COLLINS, CO 80524 Approx: 3730 CELTIC LN NTS SINGLE-LINE DIAGRAM PV-1 1 PV-1 3003 12/20/18 I.S. 99569 SINGLE-LINE DIAGRAM WATERGLEN SOLAR ARRAY THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE 5 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 6 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 7 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 3 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.8 (D). 4 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). \opt\cad\final\stephen-gold-design_125090-single-line-diagram_image.png