HomeMy WebLinkAboutRENNAT SUBDIVISION - FDP200006 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANS (2)S. TIMBERLINE RD. KECHTER RD. ZEPHYR RD. ALLEY (PRIVATE) 10' TRAVEL LANE 18.58' - 31" DRIVE-OVER CURB & GUTTER 10' TRAVEL LANE 11' TRAVEL LANE 9' UTIL. 76' ROW ESMT. 6' 54' - PKWY 6' PKWY 9' UTIL. ESMT. MINOR COLLECTOR 5' WALK 5' WALK 11' TRAVEL LANE 5' BIKE LANE 3' BUFFER 8' PARKING 5' BIKE LANE 3' BUFFER 8' PARKING 9' UTIL. 53' ROW ESMT. 9' UTIL. ESMT. RESIDENTIAL LOCAL 7' PARKING 30' - 16' TRAVEL 4.5' WALK 4.5' WALK 5.58' PKWY TBC-WALK 5.58' PKWY TBC-WALK 7' PARKING 1' x 1' CONCRETE EDGE 8' UTIL. ESMT. 8' UTIL. ESMT. ALLEY (PRIVATE) - INVERTED CROWN 10' TRAVEL LANE 20' - 10' TRAVEL LANE 8' UTIL. ESMT. 8' UTIL. ESMT. 7' MIN FENCE SETBACK GENERAL NOTES 1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Final Drainage and Erosion Control Report for Rennat Subdivision dated Februaru 12, 2020 by Northern Engineering Services, Inc., shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction 12" W 12" W X SS VAULT ELEC X X X X X IRR WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM WM UD UD UD LID W S O E T VAULT TELE T LID VAULT TELE W S O H E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E G G G G G G UD UD UD UD UD UD UD VAULT ELEC S X X X X X X X X X X X X X X X SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W 76' ROW 54' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT X X BLOCK 1 BLOCK 1 TRACT M TRACT N DU&PAE BLOCK 2 BLOCK 3 BLOCK 3 TRACT K DUA&EAE 5' TRAIL 5' TRAIL 6' UTILITY EASEMENT 53' ROW 30' FL-FL 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT BLOCK 16 BLOCK 5 BLOCK 4 TRACT T DUE TRACT J LOT 8 LOT 9 LOT 10 DETENTION POND 1 5' TRAIL TRACT M 8' UTILITY EASEMENT 19.5' EOC-FL 5' TRAIL 5' TRAIL 5' TRAIL WINDY WILLOW DR 18.4% 25.6% 24.3% 27.2% 50.69 50.98 50.79 51.22 53.38 51.42 51.88 53.18 52.91 53.25 54.89 54.42 55.07 56.46 59.31 56.26 58.03 61.17 62.31 62.11 60.69 59.86 54.08 58.88 58.07 STA. = 18+97.04 (MISTY MEADOW DRIVE) STA. = 10+00.00 (CROAKING TOAD DRIVE) 53' ROW 30' FL-FL (MISTY MEADOW DRIVE) (WINDY WILLOW DRIVE) STA. = 21+38.04 (MISTY MEADOW DRIVE) STA. = 10+00.00 (FLYING MALLARD DRIVE) MISTY MEADOW DR LOT 4 LOT 15 LOT 14 LOT 1 LOT 2 LOT 10 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 7 LOT 6 LOT 5 LOT 3 LOT 2 LOT 1 LOT 1 LOT 2 TRACT S DUA TRACT D DUA&EAE FLYING MALLARD DR SEE SHEET R8 PROPOSED DRIVE OVER CURB AND GUTTER BLOCK 12 BLOCK 12 BLOCK 10 BLOCK 14 BLOCK 15 BLOCK 16 BLOCK 13 PROPOSED 6' CROSSPAN TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G ∆ 30' FL-FL 53' ROW STA. = 23+79.04 (MISTY MEADOW DRIVE) STA. = 24+49.90 (WINDY WILLOW DRIVE) MISTY MEADOW DR LOT 2 LOT 11 LOT 4 LOT 3 LOT 1 LOT 15 LOT 12 LOT 10 LOT 11 LOT 9 LOT 8 LOT 7 LOT 15 LOT 6 LOT 5 TRACT M TRACT D DUA&EAE ZEPHYR RD SEE SHEET R13 BLOCK 4 ZEPHYR RD SEE SHEET R13 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G LOT 15 LOT 17 LOT 16 LOT 3 LOT 1 LOT 2 LOT 12 LOT 6 LOT 10 LOT 9 LOT 8 LOT 7 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1 LOT 14 LOT 2 LOT 10 LOT 9 LOT 2 LOT 1 LOT 3 LOT 1 53' ROW 30' FL-FL TRACT S DUA BLOCK 7 BLOCK 9 BLOCK 8 BLOCK 13 BLOCK 14 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+25 -2.20% 2.20% -6.00% -0.50% -2.00% -2.00% -2.00% PVI STA = 10+00.00 PVI ELEV = 4965.71 PVI STA = 10+13.83 PVI ELEV = 4965.40 PVI STA = 16+96.43 PVI ELEV = 4949.11 PVI STA = 16+76.59 PVI ELEV = 4948.80 PVI STA = 16+79.59 PVI ELEV = 4948.73 PVI STA = 16+82.59 PVI ELEV = 4948.80 PVI STA = 10+35.00 PVI ELEV = 4964.98 128.0' VC PVI STA = 11+08.83 PVI ELEV = 4963.50 BVCS: 10+44.83 BVCE: 4964.78 EVCS: 11+72.83 EVCE: 4959.66 A.D. = 4.00 K = 32.00 50.0' VC PVI STA = 16+26.59 PVI ELEV = 4949.80 BVCS: 16+01.59 BVCE: 4949.93 EVCS: 16+51.59 EVCE: 4949.30 A.D. = 1.50 K = 33.33 220.0' VC PVI STA = 13+10.87 PVI ELEV = 4951.38 BCVS: 12+00.87 BVCE: 4957.98 ECVS: 14+20.87 EVCE: 4950.83 A.D. = 5.50 4960 4965 4970 4975 4980 4985 4960 4965 4970 4975 4980 4985 9+50 10+00 11+00 12+00 13+00 13+50 4971.64 4971.44 4972.01 4972.61 4973.13 4973.35 4973.25 4972.85 4972.13 4971.11 4970.01 4968.91 4967.81 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 24"x36" STA.=12+15.74 INV.=4967.93 FUTURE GRADE -4.40% -2.20% 2.00% 2.40% PVI STA = 10+00.00 PVI ELEV = 4971.64 PVI STA = 10+13.83 PVI ELEV = 4971.33 PVI STA = 10+16.84 PVI ELEV = 4971.26 PVI STA = 10+19.84 PVI ELEV = 4971.33 PVI STA = 10+31.84 PVI ELEV = 4971.57 PVI STA = 13+03.12 PVI ELEV = 4967.67 136.0' VC HP ELEV = 4973.35 HP STA = 11+29.98 PVI STA = 11+49.98 PVI ELEV = 4974.41 BVCS: 10+81.98 BVCE: 4972.78 EVCS: 12+17.98 EVCE: 4971.42 A.D. = 6.80 K = 20.00 LOT 2 LOT 6 LOT 1 LOT 9 LOT 7 LOT 8 LOT 12 LOT 10 LOT 11 LOT 13 LOT 3 LOT 6 LOT 5 LOT 4 LOT 2 LOT 7 LOT 10 LOT 11 LOT 8 LOT 9 LOT 3 LOT 15 LOT 14 LOT 13 LOT 1 LOT 1 TRACT I TRACT J TRACT D DUA&EAE BLOCK 12 BLOCK 16 E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 29+00 28+00 27+00 26+00 25+00 24+00 23+00 22+00 21+00 20+00 19+50 4957.96 4955.51 4954.49 4954.77 4955.28 4958.80 4957.21 4956.56 4955.99 4955.12 4954.83 4954.62 4954.46 4954.52 4954.64 4954.90 4955.02 4955.15 4955.40 PROPOSED GRADE EXISTING GROUND 15" RCP STA.=22+21.17 INV.=4949.20 PROPOSED GRADE EXISTING GROUND 0.51% PVI STA = 24+33.12 PVI ELEV = 4955.44 280.4' VC LP ELEV = 4954.46 LP STA = 22+21.29 PVI STA = 21+16.47 PVI ELEV = 4953.84 BCVS: 19+76.29 BVCE: 4958.75 ECVS: 22+56.65 EVCE: 4954.55 A.D. = 4.01 K = 70.00 15" RCP STA.=21+79.20 INV.=4948.83 H AUTUMN BREEZE CT LOT 10 LOT 9 LOT 8 LOT 5 LOT 4 LOT 3 LOT 6 BLOCK 8 LOT 7 R50'' 48.58 47.36 48.34 48.99 HP 48.08 1.0% 1.0% 1.0% 0.5% 2.0% 1.5% 2.0% 4.5' SIDEWALK 46.90 46.56 46.71 0.5% 46.65 46.80 2.0% 47.10 R50' 2.4% 2.5% 2.6% 2.8% DANCING CATTAIL DR 46.47 46.59 46.80 46.80 0.5% 0.6% 0.9% 1.7% 1.5% 0.5% 2.0% 6' CROSSPAN LOT 12 LOT 10 LOT 9 LOT 14 LOT 1 LOT 2 DANCING CATTAIL DR R50'' 45.78 45.38 46.29 1.0% 0.5% 1.0% LOT 3 LOT 2 LOT 7 LOT 1 36' FL-FL R20' R50' R58' 45.5' 47.5' PROJECTED FLOWLINE DANCING CATTAIL DR WINDY WILLOW DR 49.82 50.16 50.45 50.21 49.63 49.40 0.6% 0.7% 0.5% 0.3% 1.3% 0.5% 0.5% 0.8% 0.5% 0.5% LOT 6 49.83 49.40 50.30 50.82 50.56 49.93 50.33 51.03 50.45 53' ROW 30' FL-FL 0.5% 2.5% 2.5% 3.1% 2.8% 2.2% 2.3% 2.4% 2.5% 2.8% 50.94 50.34 57' ROW 1.0% 0.9% 0.8% 0.4% 2.8% 0.4% E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E G G G 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 A B G W LOT GRADING NOTES LEGEND 505 TYPICAL LOT GRADING PLAN VIEW ISOMETRIC VIEW GRADING PLAN TYPE "G" (GARDEN LEVEL) LOT PLAN VIEW ISOMETRIC VIEW GRADING PLAN TYPE "B" LOT PLAN VIEW ISOMETRIC VIEW GRADING PLAN 500 TYPE "A" LOT GRADING PLAN 501 TYPE "B" LOT GRADING PLAN 503 TYPE "G" (GARDEN LEVEL) LOT GRADING PLAN 504 TYPE "W" (WALKOUT LEVEL) LOT GRADING PLAN OVERLOT GRADING NOTES: 1. OVERLOT GRADING WILL UTILIZE FINISHED FRONT AND BACK LOT CORNERS AS SHOWN ON THESE GRADING PLANS. INTERIOR FINISHED LOT GRADES SHOWN ON THESE PLANS ARE EXPECTED TO BE ACHIEVED UTILIZING MATERIAL FROM THE BASEMENT EXCAVATIONS; THEREFORE, ONLY THE LOT CORNER ELEVATIONS NEED TO BE ESTABLISHED PRIOR TO ISSUANCE OF BUILDING PERMITS. INTERIOR AND SIDE LOT ELEVATIONS WILL NOT BE ACHIEVED UNTIL THE HOME IS CONSTRUCTED. INDIVIDUAL LOT GRADING CERTIFICATIONS WILL VERIFY ALL PERTINENT ELEVATIONS AFTER THE HOME HAS BEEN CONSTRUCTED. 2. THESE OVERLOT TEMPLATES DO NOT GUARANTEE AN EARTHWORK BALANCE. IMPORT AND/OR EXPORT MAY BE REQUIRED. THE INTENT OF THESE OVERLOT TEMPLATES IS TO PROVIDE GENERAL GUIDANCE FOR OVERLOT GRADING. THESE TEMPLATES MAY NOT APPLY TO ALL LOTS. FIELD CHANGES CAN BE MADE SO LONG AS LOT CORNERS AND DRAINAGE PATTERNS REMAIN PER PLAN. 3. TYPICAL OVERLOT GRADING SHALL BE AT THE DEVELOPER'S DISCRETION. THE TYPE OF FOUNDATION SHOULD BE CONSIDERED WHEN DETERMINING OVERLOT EXTENTS. TEMPLATES SHOWN ARE SUGGESTED GRADING. CONTRACTOR/DEVELOPER MAY ADJUST AS NECESSARY TO BALANCE GRADING. LOT CORNER ELEVATIONS AS SHOWN ON THESE PLANS MAY NOT BE MODIFIED WITHOUT PRIOR APPROVAL OF THE CITY AND ENGINEER. 502 TYPICAL OVERLOT GRADING LOT GRADING RECOMMENDATIONS: PLAN VIEW Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R D6 GRADING DETAILS 63 OVERLOT TEMPLATE "A" LOT OVERLOT TEMPLATE "B" LOT OVERLOT TEMPLATE WALKOUT/GARDEN LEVEL 3/03/2020 **All circled are line over text.** 9' UTILITY EASEMENT 9' UTILITY EASEMENT 5' SIDEWALK 5' SIDEWALK VERTICAL CURB AND GUTTER VERTICAL CURB AND GUTTER LOT 10 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 LOT 22 LOT 12 LOT 13 LOT 10 LOT 11 LOT 9 LOT 8 LOT 7 TRACT C FUTURE PUBLIC PARK PEDESTRIAN ACCESS EASEMENT BLOCK 1 ZEPHYR RD BLOCK 3 TRACT M BURLY TREE DR SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 15+00 4962 4964 4968 4972 4976 4962 4964 4968 4972 4976 -40 -20 0 20 40 -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 15+50 4962 4964 4968 4972 4976 4962 4964 4968 4972 4976 -40 -20 0 20 40 -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 16+00 4962 4964 4968 4972 4976 4962 4964 4968 4972 4976 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 16+50 4962 4964 4968 4972 4976 4962 4964 4968 4972 4976 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 17+00 4958 4960 4964 4968 4972 4958 4960 4964 4968 4972 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 17+50 4958 4960 4964 4968 4972 4958 4960 4964 4968 4972 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 18+00 4958 4960 4964 4968 4972 4958 4960 4964 4968 4972 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 18+50 4954 4956 4960 4964 4968 4954 4956 4960 4964 4968 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 19+00 4954 4956 4960 4964 4968 4954 4956 4960 4964 4968 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 19+50 4950 4952 4956 4960 4964 4950 4952 4956 4960 4964 -40 -20 0 20 40 -2.00% -2.00% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 20+00 4950 4952 4956 4960 4964 4950 4952 4956 4960 4964 -40 -20 0 20 40 -2.00% -1.99% SECTION LINE Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 20+50 4946 4948 4952 4956 4960 4946 4948 4952 4956 4960 -40 -20 0 20 40 -2.00% -1.97% 4968.9 4968.89 4969.3 4969.26 4969.5 4969.49 4969.8 4969.81 4968.2 4968.23 4966.5 4966.54 4964.5 4964.48 4962.6 4962.59 4961.1 4961.13 4959.6 4959.62 4957.7 4957.68 4955.5 4955.47 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE B M KEYMAP Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE NORTH ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 XS1 CROSS SECTIONS ZEPHYR RD 52 XS1 XS2 Line Over Text Line Over Text 3/03/2020 0.5% 2.3% 2.3% 0.5% 0.4% 0.5% 0.5% ALLEY 2 CROAKING TOAD DR LOT 2 LOT 1 LOT 1 LOT 17 LOT 16 46.99 47.06 47.27 47.21 47.39 47.29 47.21 47.39 47.29 47.06 47.27 46.99 47.31 47.33 47.12 47.12 47.45 47.45 0.4% 0.5% 0.4% 0.5% 0.5% 0.5% 0.5% 1.1% 0.5% 0.5% 0.5% 1.4% 2.0% 1.1% 47.48 47.75 47.55 1.0% 1.4% 0.9% 47.48 47.75 47.55 47.70 48.12 47.70 47.71 48.09 47.73 47.77 48.16 47.79 47.95 48.37 47.95 0.6% 0.7% 0.6% 0.6% 1.1% 1.8% 2.0% 2.2% 2.2% 0.8% 1.3% 0.6% 0.1% 0.1% 0.1% 0.5% 0.5% 0.8% 0.3% 0.3% 0.6% 1.1% 1.8% 2.0% 2.3% 2.3% 0.5% 1.4% 1.0% 1.4% 1.3% 1.4% 1.1% 47.48 47.55 47.63 47.14 47.14 0.5% 0.5% 0.5% 0.5% 2.2% 2.2% 2.2% 2.2% 2.2% 2.2% LOT 11 BLOCK 7 BLOCK 6 BLOCK 9 BLOCK 13 53' ROW 30' FL-FL 4.5' SIDEWALK 0.5% 0.5% 0.5% 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 53' ROW 30' FL-FL DANCING CATTAIL DR 75' CROWN TRANSITION 75' CROWN TRANSITION 6' CROSSPAN 6' CROSSPAN 47.70 47.40 LOT 10 LOT 1 LOT 2 LOT 12 LOT 13 48.49 48.83 48.65 48.59 48.77 48.89 48.87 48.94 48.87 48.49 49.11 49.30 48.92 0.5% 0.5% 2.3% 2.3% 2.3% 2.3% 0.5% 1.3% 0.9% 48.92 49.24 49.00 1.0% 1.4% 0.9% 49.41 49.93 49.41 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 48.68 0.5% 49.29 49.79 49.32 48.68 0.6% 0.7% 0.5% 49.10 LOT 7 LOT 9 LOT 8 LOT 6 BLOCK 6 BLOCK 14 BLOCK 15 53' ROW 30' FL-FL DANCING CATTAIL DR FLYING MALLARD DR 75' CROWN TRANSITION 0.7% 0.0% 1.0% 0.5% 2.1% 1.9% 2.2% 2.2% 0.5% 0.5% 0.6% 0.4% 1.2% 1.2% 1.8% 2.0% 2.3% 2.3% 57' ROW 36' FL-FL 30' FL-FL TELE VAULT ELEC VAULT ELEC VAULT ELEC X X X E E G G G G T T T T T LOT 3 LOT 4 LOT 1 LOT 2 55.58 55.18 55.37 0.8% ZEPHYR RD ROSEN DRIVE RED WILLOW DRIVE 55.66 55.79 LOT 2 TRACT E DG&PAE BLOCK 1 54.34 54.92 54.28 (55.09) 55.20 0.7% 0.5% 1.4% 1.9% 1.7% 55.04 55.17 55.30 54.65 54.48 54.71 54.97 55.30 54.93 0.9% 1.6% 0.1% 1.2% 0.8% 0.7% 0.5% 0.5% 1.4% 1.4% 4.1% 87' CROWN TRANSITION CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP INT3 INTERSECTION DETAILS 49 A G H K EYEBROW DETAIL K C D E F L I J B K INTERSECTION DETAIL K L NORTH INTERSECTION DETAIL INTERSECTION DETAIL 3/03/2020 Incorrect Sheet Numbering 1.0% 44.20 45.23 45.86 2.0% 0.0% 0.5% BLOCK 7 BLOCK 8 4.5' SIDEWALK 4.5' SIDEWALK 2.2% 2.2% 46.28 45.86 53' ROW 30' ROW R50' 3.0% 2.7% 2.3% 2.0% 2.0% PROPOSED FOREBAY 2 (SEE DETAIL SHEET D4) WQ POND 2 LOT 10 61.63 61.80 61.72 63.19 62.24 62.56 63.24 61.71 63.63 62.09 1.9% 2.5% 2.0% 2.4% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 64.92 62.87 3.2% 2.4% 2.6% 61.41 61.53 61.11 3.3% 2.6% 2.9% 30' FL-FL 53' ROW MISTY MEADOW DR DANCING CATTAIL DR 60.99 61.20 60.75 58.95 58.40 58.47 2.4% 2.0% 60.11 59.74 59.55 2.4% 1.3% 60.95 60.69 60.47 2.0% 0.5% 1.8% 0.2% 1.5% 0.3% 62.14 1.2% 1.6% 3.4% 4.2% 4.4% 4.4% 3.7% 3.8% 2.9% 0.3% 0.4% 2.1% 3.8% 62.49 2.0% 2.0% 2.0% 2.0% 36' FL-FL 57' FL-FL LOT 11 LOT 1 LOT 2 TRACT C FUTURE PUBLIC PARK PEDESTRIAN ACCESS EASEMENT BLOCK 5 BLOCK 16 100' CROWN TRANSITION 4.5' SIDEWALK 4.5' SIDEWALK LOT 2 LOT 3 LOT 1 LOT 9 55.79 55.18 55.53 56.20 56.44 56.59 56.29 55.18 56.59 56.42 57.25 55.84 2.0% 2.0% 2.1% 2.6% 2.0% 2.0% 2.8% 3.1% 3.3% 1.8% 1.7% 1.6% MISTY MEADOW DR LOT 10 LOT 11 BLOCK 4 BLOCK 1 TRACT C FUTURE PUBLIC PARK PEDESTRIAN ACCESS EASEMENT ZEPHYR RD 30' FL-FL 53' ROW 75' CROWN TRANSITION 57.38 56.54 55.87 55.52 56.97 56.96 2.1% 2.2% 56.88 56.46 56.56 2.2% 1.5% 56.19 56.24 1.8% 1.2% 2.0% 0.9% 2.0% 1.9% 1.6% 2.0% 2.0% 2.2% 2.2% 2.2% 1.0% 1.0% 1.9% 2.5% 2.2% 0.5% 1.6% 1.5% 2.2% 0.1% 54' FL-FL 76' ROW 4.5' SIDEWALK 5' SIDEWALK 4.5' SIDEWALK 8' CROSSPAN 55.76 2.8% 2.3% CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP INT2 INTERSECTION DETAILS 49 A G H G CUL-DE-SAC DETAIL H CUL-DE-SAC DETAIL K C D E F L I J B E INTERSECTION DETAIL INTERSECTION DETAIL F NORTH 3/03/2020 Incorrect Sheet Numbering Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC S S X X SS SS SS SS SS E G G G T T T W W W W W W RED WILLOW DR ROSEN DRIVE PROPOSED "STOP" SIGN w/ STREET NAMES 13' PROJECTED FL "25 MPH SPEED LIMIT" SIGN S SS SS T W W STA. = 20+55.65 (ZEPHYR RD) STA. = 27+57.92 (MISTY MEADOW DRIVE) 5' SIDEWALK 9' UTILITY EASEMENT 5' SIDEWALK PROPOSED VERTICAL CURB AND GUTTER MISTY MEADOW DR SEE SHEET R3 9' UTILITY EASEMENT 76' ROW 54' FL-FL ZEPHYR RD ROSEN DRIVE "NO PARKING" SIGNS "NO PARKING TO CORNER" SIGN 13' PROJECTED FL 13' SIGHT DISTANCE TRIANGLE 310' @ 30 MPH (DESIGN) SIGHT DISTANCE TRIANGLE 310' @ 30 MPH (DESIGN) ∆ ∆ ∆ STORM DRAIN 2 SEE SHEET ST2 STORM DRAIN 1 SEE SHEET ST1 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 29+00 28+00 27+00 26+00 25+00 24+00 23+00 22+00 21+00 20+00 19+50 -0.50% 0.50% 0.68% 1.80% PVI STA = 21+94.03 PVI ELEV = 4953.73 PVI STA = 22+29.56 PVI ELEV = 4953.90 PVI STA = 23+87.21 PVI ELEV = 4955.64 197.6' VC PVI STA = 20+65.99 PVI ELEV = 4954.37 BCVS: 19+67.22 BVCE: 4958.11 ECVS: 21+64.77 EVCE: 4953.87 A.D. = 3.29 K = 60.00 67.2' VC PVI STA = 23+28.43 PVI ELEV = 4954.58 BCVS: 22+94.84 BVCE: 4954.35 ECVS: 23+62.01 EVCE: 4955.18 A.D. = 1.12 K = 60.00 4956.96 4954.55 4953.76 4954.39 4957.82 4956.20 4955.55 4954.99 4954.21 4953.97 4953.82 4953.88 4954.04 4954.21 4954.63 4954.98 4955.42 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 15" RCP STA.=21+54.52 INV.=4949.00 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 29+00 28+00 27+00 26+00 25+00 24+00 23+00 22+00 21+00 20+00 19+50 4957.60 4955.15 4953.94 4953.96 4954.54 4958.39 4956.87 4956.22 4955.65 4954.74 4954.39 4954.13 4953.82 4953.71 4953.83 4954.08 4954.21 4954.33 4954.75 4954.96 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 15" RCP STA.=22+03.88 INV.=4948.66 0.85% 0.50% -0.50% 0.50% PVI STA = 22+48.32 PVI ELEV = 4953.70 PVI STA = 22+89.79 PVI ELEV = 4953.91 PVI STA = 23+78.39 PVI ELEV = 4954.35 PVI STA = 24+70.70 PVI ELEV = 4955.14 223.0' VC PVI STA = 20+96.06 PVI ELEV = 4954.46 BCVS: 19+84.56 BVCE: 4958.08 ECVS: 22+07.56 EVCE: 4953.90 A.D. = 2.75 K = 81.11 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 LINE MATCH STA 24+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE LINE MATCH STA 24+00 LINE MATCH STA 19+50 NORTH CENTERLINE ZEPHYR RD SCALE : 1" = 40' (H) 1" = 5' (V) B M KEYMAP G G R13 PLAN AND PROFILE ZEPHYR RD 46 LEFT FLOWLINE ZEPHYR RD SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE ZEPHYR RD SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R12 STA 19+50 G 3/03/2020 Line Over Text E E E E E E E E E G G G G G G G G G G G G G G G G E E E E E G G G G E E E E E E E E E G G G G G WINDY WILLOW DR LOT 2 BLOCK 5 18.58' FL-EOC PROPOSED DRIVE OVER CURB AND GUTTER PROPOSED 1' CONCRETE RIBBON DANCING CATTAIL DR STA. = 16+14.53 (ALLEY 2) STA. = 18+16.70 (DANCING CATTAIL DR) STORM DRAIN 1 SEE SHEET ST1 ALLEY 2 MISTY MEADOW DR 9' UTILITY EASEMENT 4.5' SIDEWALK ∆ STA. = 10+00.00 (ALLEY 2) STA. = 22+49.95 (MISTY MEADOW DR) 5' TRAIL 5' TRAIL PROPOSED 2' SIDEWALK CHASE 4945 4950 4955 4960 4965 4970 4975 4945 4950 4955 4960 4965 4970 4975 16+50 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 1.03% PROPOSED GRADE EXISTING GROUND -5.23% -5.22% -0.50% -4.83% -4.83% -1.26% -0.90% PVI STA = 10+26.70 PVI ELEV = 4965.62 PVI STA = 10+56.70 PVI ELEV = 4964.17 PVI STA = 11+92.15 PVI ELEV = 4957.34 PVI STA = 14+23.95 PVI ELEV = 4950.63 PVI STA = 14+48.95 PVI ELEV = 4950.40 PVI STA = 15+78.08 PVI ELEV = 4949.76 PVI STA = 15+80.91 PVI ELEV = 4949.76 PVI STA = 15+88.03 PVI ELEV = 4949.83 35.4' VC PVI STA = 11+16.44 PVI ELEV = 4961.29 BVCS: 10+98.76 BVCE: 4962.14 EVCS: 11+34.12 EVCE: 4960.36 A.D. = 0.38 K = 92.23 84.7' VC PVI STA = 12+87.61 PVI ELEV = 4952.34 BCVS: 12+45.27 BVCE: 4954.56 ECVS: 13+29.94 EVCE: 4951.81 A.D. = 3.98 K = 21.28 4963.29 4962.08 4960.83 4959.54 4958.23 4956.93 4955.62 4954.31 4953.21 4952.39 4951.88 4951.56 4951.24 4950.93 4950.62 4950.40 4950.27 4950.15 4950.02 4949.90 4949.77 EXISTING GROUND PROPOSED GRADE 24" RCP STORM STA.=12+40.86 INV.=4947.11 PROPOSED 2' CURB CUT STA.=15+79.49 EL. = 4949.758 B M KEYMAP NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE R11 PLAN AND PROFILE ALLEY 2 44 RIGHT FLOWLINE ALLEY 2 SCALE : 1" = 40' (H) 1" = 5' (V) ALLEY 2 Line Over Text 3/03/2020 TIE TO EXISTING STA.=12+12.40 EL. = 4971.644 FO FO FO FO FO FO E E E E E E FALLEN BRANCH DR 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT LOT 1 LOT 8 LOT 6 LOT 7 LOT 9 LOT 16 LOT 15 STA. = 10+00.00 (FALLEN BRANCH DRIVE) STA. = 14+96.68 (MISTY MEADOW DRIVE) MISTY MEADOW DR SEE SHEET R1 MISTY MEADOW DR SEE SHEET R2 PROPOSED DRIVE OVER CURB AND GUTTER PLANNED HANSEN FARM PLANNED HANSEN FARM PLANNED 24"x36" RCBC BLOCK 12 BLOCK 11 BLOCK 10 TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT DITCH LATERAL "STOP" SIGN W/ STREET NAMES KNOBBY PINE DRIVE KNOBBY PINE DRIVE 30' EASEMENT REC. NO. 20140004033 15' EASEMENT REC. NO. 20110070565 36' FL-FL 59' ROW 4960 4965 4970 4975 4980 4985 4960 4965 4970 4975 4980 4985 9+50 10+00 11+00 12+00 13+00 13+50 -4.38% 2.40% 1.60% 2.00% PVI STA = 10+16.56 PVI ELEV = 4971.07 PVI STA = 13+03.12 PVI ELEV = 4967.19 PVI STA = 10+46.64 PVI ELEV = 4971.55 PVI STA = 10+74.18 PVI ELEV = 4972.11 136.0' VC HP ELEV = 4972.86 HP STA = 11+29.70 PVI STA = 11+49.57 PVI ELEV = 4973.91 BVCS: 10+81.57 BVCE: 4972.28 EVCS: 12+17.57 EVCE: 4970.93 A.D. = 6.78 K = 20.05 4971.21 4972.12 4972.64 4972.85 4972.76 4972.35 4971.63 4970.61 4969.51 4968.42 4967.32 24"x36" STA.=12+14.98 INV.=4967.96 TIE TO EXISITNG STA.=12+12.40 EL. = 4971.153 4960 4965 4970 4975 4980 4985 4960 4965 4970 4975 4980 4985 9+50 10+00 11+00 12+00 13+00 13+50 -4.40% 2.00% 2.40% 1.62% PVI STA = 10+17.11 PVI ELEV = 4971.07 PVI STA = 10+46.64 PVI ELEV = 4971.55 PVI STA = 10+71.98 PVI ELEV = 4972.05 PVI STA = 13+03.12 PVI ELEV = 4967.19 136.0' VC HP ELEV = 4972.87 HP STA = 11+29.98 PVI STA = 11+49.98 PVI ELEV = 4973.92 BVCS: 10+81.98 BVCE: 4972.29 EVCS: 12+17.98 EVCE: 4970.93 A.D. = 6.80 K = 20.00 -4.40% 2.00% 2.40% 1.62% PVI STA = 10+17.11 PVI ELEV = 4971.07 PVI STA = 10+46.64 PVI ELEV = 4971.55 PVI STA = 10+71.98 PVI ELEV = 4972.05 PVI STA = 13+03.12 PVI ELEV = 4967.19 136.0' VC HP ELEV = 4972.87 HP STA = 11+29.98 PVI STA = 11+49.98 PVI ELEV = 4973.92 BVCS: 10+81.98 BVCE: 4972.29 EVCS: 12+17.98 EVCE: 4970.93 A.D. = 6.80 K = 20.00 4971.19 4972.12 4972.64 4972.86 4972.77 4972.36 4971.64 4970.62 4969.52 4968.42 4967.32 24"x36" STA.=12+16.50 INV.=4967.90 TIE TO EXISTING STA.=12+12.40 EL. = 4971.167 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE CENTERLINE FALLEN BRANCH DR SCALE : 1" = 40' (H) 1" = 5' (V) B M KEYMAP E R9 PLAN & PROFILE FALLEN BRANCH DR 42 LEFT FLOWLINE FALLEN BRANCH DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE FALLEN BRANCH DR SCALE : 1" = 40' (H) 1" = 5' (V) 3/03/2020 Line Over Text Line Over Text K = 40.00 4965.71 4963.20 4958.03 4953.26 4950.99 4950.43 4949.93 4965.18 4964.04 4962.17 4960.95 4959.53 4956.60 4955.33 4952.46 4951.81 4951.32 4950.81 4950.68 4950.56 4950.31 4950.18 4950.06 4949.73 4949.33 4948.83 24" RCP STA.=12+76.54 INV.=4946.66 PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE E E E E E E E E E E E E E G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G MISTY MEADOW DR SEE SHEET R2 DANCING CATTAIL DR SEE SHEET R4 LOT 9 LOT 5 LOT 89 LOT 10 LOT 11 LOT 15 LOT 13 LOT 14 LOT 1 LOT 2 LOT 4 LOT 3 LOT 5 LOT 9 LOT 6 LOT 7 LOT 8 LOT 12 LOT 10 LOT 11 LOT 13 LOT 7 LOT 6 LOT 12 LOT 11 LOT 3 LOT 6 LOT 7 LOT 82 LOT 5 LOT 4 LOT 1 LOT 2 LOT 8 LOT 12 TRACT I TRACT H TRACT G TRACT Q TRACT S DUA PROPOSED VERTICAL CURB AND GUTTER BLOCK 14 BLOCK 15 BLOCK 16 TRACT A DRAINAGE & PEDESTRIAN ACCESS EASEMENT 4.5' SIDEWALK STORM DRAIN 1 SEE SHEET ST1 FLYING MALLARD DR 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT TRACT D DUA&EAE STA. = 10+00.00 (FLYING MALLARD DR) STA. = 21+38.04 (MISTY MEADOW DR) BLOCK 6 STA. = 16+96.43 (FLYING MALLARD DR) STA. = 17+04.78 (DANCING CATTAIL DR) DANCING CATTAIL DR SEE SHEET R4 MISTY MEADOW DR SEE SHEET R2 57' ROW 36' FL-FL ∆ ∆ ∆ 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+25 -6.23% -2.10% -0.90% -0.51% PVI STA = 10+35.00 PVI ELEV = 4964.54 PVI STA = 16+66.42 PVI ELEV = 4948.78 PVI STA = 16+06.34 PVI ELEV = 4949.32 124.0' VC PVI STA = 11+09.30 PVI ELEV = 4962.98 BVCS: 10+47.30 BVCE: 4964.28 EVCS: 11+71.30 EVCE: 4959.12 A.D. = 4.13 K = 30.01 229.0' VC PVI STA = 13+03.74 PVI ELEV = 4950.86 BCVS: 11+89.24 BVCE: 4958.00 ECVS: 14+18.24 EVCE: 4950.28 A.D. = 5.72 K = 40.02 4964.22 4963.57 4962.71 4961.64 4960.37 4958.88 4957.34 4955.93 4954.67 4953.57 4952.63 4951.84 4951.21 4950.73 4950.41 4950.24 4950.12 4949.99 4949.86 4949.73 4949.61 4949.48 4949.35 4949.15 4948.92 PROPOSED GRADE EXISTING GROUND EXISTING GROUND 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+25 -5.79% -0.49% -1.30% -2.00% PVI STA = 10+35.00 PVI ELEV = 4964.46 PVI STA = 16+92.77 PVI ELEV = 4948.60 130.0' VC PVI STA = 11+08.35 PVI ELEV = 4962.99 BVCS: 10+43.35 BVCE: 4964.29 EVCS: 11+73.35 EVCE: 4959.23 A.D. = 3.79 K = 34.33 49.8' VC PVI STA = 16+39.68 PVI ELEV = 4949.28 BVCS: 16+14.77 BVCE: 4949.41 EVCS: 16+64.58 EVCE: 4948.96 A.D. = 0.80 K = 62.22 228.1' VC PVI STA = 13+17.72 PVI ELEV = 4950.88 BCVS: 12+03.67 BVCE: 4957.48 ECVS: 14+31.77 EVCE: 4950.31 A.D. = 5.29 K = 43.10 4964.15 4963.51 4962.69 4961.69 4960.50 4959.14 4957.69 4956.30 4955.04 4953.94 4952.98 4952.16 4951.49 4950.97 4950.59 4950.35 4950.22 4950.10 4949.98 4949.85 4949.73 4949.60 4949.48 4949.35 4949.13 4948.83 PROPOSED GRADE EXISTING GROUND EXISTING GROUND CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH CENTERLINE FLYING MALLARD DR SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP D R8 PLAN AND PROFILE FLYING MALLARD DR 41 LEFT FLOWLINE FLYING MALLARD DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE FLYING MALLARD DR SCALE : 1" = 40' (H) 1" = 5' (V) Cut Off Text Cut Off Text Line Over Text 3/03/2020 G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E G G G G G G G G G G G DANCING CATTAIL DR AUTUMN BREEZE CT SEE SHEET INT1 CROAKING TOAD DR SEE SHEET R6 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT PROPOSED DRIVE OVER CURB AND GUTTER CURB CUT & CONCRETE RUNDOWN "STOP" SIGN w/ STREET NAMES "STOP" SIGN w/ STREET NAMES STA. = 14+63.78 (DANCING CATTAIL DRIVE) STA. = 18+72.79 (CROAKING TOAD DRIVE) STA. = 11+54.75 (DANCING CATTAIL DRIVE) STA. = 10+29.73 (AUTUMN BREEZE CT) LOT 11 LOT 10 LOT 9 LOT 13 LOT 11 LOT 8 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50 4946.28 4946.78 4947.28 4947.78 4948.04 4947.58 4948.58 4946.40 4946.53 4946.65 4946.90 4947.03 4947.15 4947.40 4947.53 4947.65 4947.90 4948.03 4948.15 4947.63 4947.25 4947.31 4948.04 4948.32 4948.46 4948.71 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 2.20% -2.20% 2.00% -2.00% 0.50% 0.50% PVI STA = 10+00.00 PVI ELEV = 4946.28 PVI STA = 14+43.95 PVI ELEV = 4947.25 PVI STA = 14+46.95 PVI ELEV = 4947.18 PVI STA = 14+49.95 PVI ELEV = 4947.25 PVI STA = 14+63.78 PVI ELEV = 4947.55 PVI STA = 14+77.62 PVI ELEV = 4947.25 PVI STA = 14+80.62 PVI ELEV = 4947.18 PVI STA = 14+83.62 PVI ELEV = 4947.25 50.0' VC HP ELEV = 4948.15 HP STA = 13+78.96 PVI STA = 13+93.95 PVI ELEV = 4948.25 BVCS: 13+68.95 BVCE: 4948.12 EVCS: 14+18.95 EVCE: 4947.75 A.D. = 2.50 K = 20.00 50.0' VC PVI STA = 15+33.62 PVI ELEV = 4948.25 BVCS: 15+08.62 BVCE: 4947.75 EVCS: 15+58.62 EVCE: 4948.37 A.D. = 1.50 K = 33.33 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50 0.50% -1.38% 2.50% -2.50% 1.38% 0.50% PVI STA = 10+00.00 PVI ELEV = 4945.86 PVI STA = 14+43.95 PVI ELEV = 4947.13 PVI STA = 14+46.95 PVI ELEV = 4947.06 PVI STA = 14+49.95 PVI ELEV = 4947.13 PVI STA = 14+63.78 PVI ELEV = 4947.48 PVI STA = 14+77.62 PVI ELEV = 4947.13 PVI STA = 14+80.62 PVI ELEV = 4947.06 PVI STA = 14+83.62 PVI ELEV = 4947.13 50.0' VC HP ELEV = 4947.73 HP STA = 13+82.21 PVI STA = 13+93.95 PVI ELEV = 4947.82 BVCS: 13+68.95 BVCE: 4947.70 EVCS: 14+18.95 EVCE: 4947.48 A.D. = 1.88 K = 26.58 50.0' VC PVI STA = 15+33.62 PVI ELEV = 4947.82 BVCS: 15+08.62 BVCE: 4947.48 EVCS: 15+58.62 EVCE: 4947.95 A.D. = 0.88 K = 56.83 4945.86 4946.36 4946.86 4947.36 4947.67 4947.36 4948.15 4945.98 4946.11 4946.23 4946.48 4946.61 4946.73 4946.98 4947.11 4947.23 4947.48 4947.61 4947.72 4947.40 4947.13 4947.20 4947.68 4947.90 4948.03 4948.28 PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE 4935 4940 4945 4950 4955 4960 4935 4940 4945 4950 4955 4960 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50 0.50% 0.50% -1.08% 2.20% -2.20% 1.08% PVI STA = 10+00.00 PVI ELEV = 4945.86 PVI STA = 14+43.95 PVI ELEV = 4947.28 PVI STA = 14+46.95 PVI ELEV = 4947.21 PVI STA = 14+50.00 PVI ELEV = 4947.33 PVI STA = 14+63.78 PVI ELEV = 4947.63 PVI STA = 14+77.62 PVI ELEV = 4947.32 PVI STA = 14+80.62 PVI ELEV = 4947.21 PVI STA = 14+83.62 PVI ELEV = 4947.28 50.0' VC HP ELEV = 4947.74 HP STA = 13+84.71 PVI STA = 13+93.95 PVI ELEV = 4947.82 BVCS: 13+68.95 BVCE: 4947.70 EVCS: 14+18.95 EVCE: 4947.55 A.D. = 1.58 K = 31.60 50.0' VC PVI STA = 15+33.62 PVI ELEV = 4947.82 BVCS: 15+08.62 BVCE: 4947.55 EVCS: 15+58.62 EVCE: 4947.95 A.D. = 0.58 K = 86.09 4945.86 4945.98 4946.11 4946.23 4946.36 4946.48 4946.61 4946.73 4946.86 4946.98 4947.11 4947.23 4947.36 4947.48 4947.61 4947.72 4947.70 4947.49 4947.33 4947.38 4947.46 4947.71 4947.90 4948.03 4948.15 4948.28 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 NORTH LINE MATCH STA 16+50 CENTERLINE DANCING CATTAIL DR SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP B B B2 R4 PLAN AND PROFILE DANCING CATTAIL DR 37 MATCH LINE SEE SHEET R5 STA 16+50 LEFT FLOWLINE DANCING CATTAIL DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE DANCING CATTAIL DR SCALE : 1" = 40' (H) 1" = 5' (V) **All circled are line over text.** 3/03/2020 G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E G G G G "STOP" SIGN w/ STREET NAMES 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK STA. = 27+57.92 (MISTY MEADOW DRIVE) STA. = 20+55.15 (ZEPHYR RD) WINDY WILLOW DR SEE SHEET R5 PROPOSED DRIVE OVER CURB AND GUTTER LOT 2 LOT 1 BLOCK 1 BLOCK 5 ∆ ∆ STORM DRAIN 1 SEE SHEET ST1 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 23+00 24+00 25+00 26+00 27+00 28+00 29+00 EXISTING GROUND PROPOSED GRADE 4962.45 4960.45 4958.45 4956.45 4963.95 4963.45 4962.95 4961.95 4961.45 4960.95 4959.95 4959.45 4958.95 4957.95 4957.45 4956.95 4955.95 4956.28 PROPOSED GRADE EXISTING GROUND 1.86% -2.00% PVI STA = 27+24.87 PVI ELEV = 4955.96 PVI STA = 27+28.87 PVI ELEV = 4955.86 PVI STA = 27+32.88 PVI ELEV = 4955.96 PVI STA = 27+57.92 PVI ELEV = 4956.42 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 23+00 24+00 25+00 26+00 27+00 28+00 29+00 -0.53% -1.98% PVI STA = 27+37.52 PVI ELEV = 4956.20 50.5' VC PVI STA = 26+88.29 PVI ELEV = 4956.46 BCVS: 26+63.06 BVCE: 4956.95 ECVS: 27+13.52 EVCE: 4956.32 A.D. = 1.45 K = 34.85 4963.64 4963.14 4962.65 4962.15 4961.66 4961.16 4960.67 4960.18 4959.68 4959.19 4958.69 4958.20 4957.71 4957.21 4956.74 4956.42 4956.26 PROPOSED GRADE EXISTING GROUND 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 23+00 24+00 25+00 26+00 27+00 28+00 29+00 -1.62% -2.02% PVI STA = 26+95.83 PVI ELEV = 4955.94 PVI STA = 27+20.83 PVI ELEV = 4955.53 4963.43 4962.93 4962.42 4961.92 4961.41 4960.91 4960.40 4959.90 4959.39 4958.88 4958.38 4957.87 4957.37 4956.86 4956.36 4955.87 PROPOSED GRADE EXISTING GROUND NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 LINE MATCH STA 23+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP A A R3 PLAN AND PROFILE MISTY MEADOW DR 36 A CENTERLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R2 STA 23+00 Line Over Text 3/03/2020 G G G G G G G G G E E E E E E E E G G G G G E E E E E E E E E G G G G G G G G 9' UTILITY EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 4.5' SIDEWALK 9' UTILITY EASEMENT 5' TRAIL CROAKING TOAD DR SEE SHEET R7 ALLEY 1 ALLEY 2 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 15+75 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 EXISTING GROUND PROPOSED GRADE 4969.46 4967.23 4965.23 4964.02 4965.02 4965.52 4965.95 4968.80 4968.23 4967.73 4966.73 4966.23 4965.73 4964.73 4964.23 4963.73 4964.48 4964.76 4964.89 4965.14 4965.27 4965.39 4965.64 4965.77 4965.89 4965.80 4965.45 4964.95 PROPOSED GRADE EXISTING GROUND -2.00% 2.00% 0.50% -3.00% -2.00% PVI STA = 18+77.20 PVI ELEV = 4963.68 PVI STA = 18+80.20 PVI ELEV = 4963.61 PVI STA = 18+83.20 PVI ELEV = 4963.68 50.0' VC PVI STA = 19+33.20 PVI ELEV = 4964.68 BVCS: 19+08.20 BVCE: 4964.18 EVCS: 19+58.20 EVCE: 4964.81 A.D. = 1.50 K = 33.33 76.4' VC HP ELEV = 4965.95 HP STA = 21+94.62 PVI STA = 22+17.54 PVI ELEV = 4966.10 BVCS: 21+79.34 BVCE: 4965.91 EVCS: 22+55.74 EVCE: 4965.34 A.D. = 2.50 K = 30.56 75.0' VC PVI STA = 16+21.26 PVI ELEV = 4968.80 BCVS: 15+83.76 BVCE: 4969.93 ECVS: 16+58.76 EVCE: 4968.05 A.D. = 1.00 K = 75.00 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 15+75 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 4969.14 4966.88 4964.88 4963.87 4964.58 4965.08 4965.53 4968.48 4967.89 4967.38 4966.38 4965.88 4965.38 4964.41 4964.06 4963.84 4964.06 4964.28 4964.45 4964.70 4964.83 4964.95 4965.20 4965.33 4965.45 4965.42 4965.10 4964.62 -3.00% -1.98% -2.00% 0.50% -0.50% 0.50% 0.90% PVI STA = 18+83.95 PVI ELEV = 4963.79 PVI STA = 19+08.95 PVI ELEV = 4963.91 PVI STA = 19+61.95 PVI ELEV = 4964.39 75.0' VC PVI STA = 16+25.01 PVI ELEV = 4968.38 BCVS: 15+87.51 BVCE: 4969.51 ECVS: 16+62.51 EVCE: 4967.63 A.D. = 1.00 K = 75.10 75.1' VC PVI STA = 18+44.89 PVI ELEV = 4963.98 BCVS: 18+07.34 BVCE: 4964.73 ECVS: 18+82.44 EVCE: 4963.79 A.D. = 1.50 K = 50.02 PROPOSED GRADE EXISTING GROUND 76.4' VC HP ELEV = 4965.53 HP STA = 21+98.52 PVI STA = 22+21.29 PVI ELEV = 4965.68 BVCS: 21+83.09 BVCE: 4965.49 EVCS: 22+59.49 EVCE: 4964.93 A.D. = 2.48 K = 30.85 EXISTING GROUND PROPOSED GRADE 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 15+75 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 STREET A Right Flowline 4966.84 4966.59 4966.77 4966.88 4966.98 4967.59 4967.95 4966.69 4966.60 4966.59 4966.63 4966.63 4966.67 4967.01 4966.78 4966.76 4966.79 4967.19 4967.38 4967.50 4967.62 4967.67 4967.75 4968.22 4968.32 4968.39 -3.00% 1.52% 0.50% -1.36% -2.00% -2.02% PVI STA = 18+73.45 PVI ELEV = 4963.50 PVI STA = 18+76.45 PVI ELEV = 4963.43 PVI STA = 18+79.45 PVI ELEV = 4963.50 50.0' VC PVI STA = 19+29.45 PVI ELEV = 4964.26 BVCS: 19+04.45 BVCE: 4963.88 EVCS: 19+54.45 EVCE: 4964.39 A.D. = 1.02 K = 49.01 75.7' VC HP ELEV = 4965.53 HP STA = 21+90.86 PVI STA = 22+13.71 PVI ELEV = 4965.68 BVCS: 21+75.84 BVCE: 4965.49 EVCS: 22+51.57 EVCE: 4964.92 A.D. = 2.52 K = 30.03 75.0' VC PVI STA = 16+17.51 PVI ELEV = 4968.38 BCVS: 15+80.01 BVCE: 4969.51 ECVS: 16+55.01 EVCE: 4967.63 A.D. = 1.00 K = 75.00 75.0' VC PVI STA = 18+35.95 PVI ELEV = 4964.01 BCVS: 17+98.44 BVCE: 4964.76 ECVS: 18+73.45 EVCE: 4963.50 A.D. = 0.64 K = 117.29 PROPOSED GRADE EXISTING GROUND NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 LINE MATCH STA 15+75 LINE MATCH STA 23+00 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED CURB & GUTTER PROPOSED CENTERLINE PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO FACE OF WALK PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE B M KEYMAP A A R2 PLAN AND PROFILE MISTY MEADOW DR 35 A CENTERLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE MISTY MEADOW DR SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE SEE SHEET R1 STA 15+75 MATCH LINE SEE SHEET R3 STA 23+00 **All circled are line over text.** 3/03/2020 53.04 53.24 57.26 56.47 53.44 54.48 54.59 55.01 55.76 58.98 STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 52.85 50.98 51.08 51.17 52.27 53.46 58.52 58.52 60.09 60.46 59.68 58.34 56.34 55.22 52.35 52.46 52.51 52.92 55.05 50.33 48.37 48.80 48.95 47.85 8.00' UTILITY EASEMENT 19.50' EOC-FL B FG=56.24 TF=56.91 LOT 6 15.5% 19.1% 20.8% B FG=58.06 TF=58.73 LOT 1 B FG=58.87 TF=59.54 LOT 2 B FG=59.69 TF=60.36 LOT 3 B FG=59.69 TF=60.36 LOT 4 B FG=62.42 TF=63.09 LOT 1 B FG=61.97 TF=62.64 LOT 2 B FG=60.12 TF=60.79 LOT 3 B FG=55.12 TF=55.79 LOT 4 B FG=54.40 TF=55.07 LOT 5 T FG=53.95 TF=54.62 LOT 6 A FG=53.64 TF=54.31 LOT 7 B FG=54.55 TF=55.22 LOT 1 53.90 59.62 61.47 59.19 58.37 57.56 53.14 53.45 53.22 19.5' EOC-FL 5.3% 5.3% 56.74 0.5% 0.5% 1' RIBBON CURB VERTICAL CURB AND GUTTER STORM DRAIN 1 SEE SHEET ST1 0.5% 0.5% 18.50' EMERGENCY SPILLWAY 52.85 53.02 52.98 53.49 2.0% 2.0% 1.4% 0.0% 0.5% 0.5% 0.5% 53.20 55.07 54.94 52.79 54.64 17.0% 15.9% 19.6% 17.4% 1.9% 2.0% 2.1% 2.0% 2.0% LINE TABLE LINE L1 L3 L5 L6 L9 L10 L12 L13 L41 L44 L45 L48 L49 LENGTH 61.99' 94.84' 35.65' 144.68' 35.23' 92.22' 140.36' 100.62' 53.34' 25.54' 104.27' 7.93' 11.64' BEARING S89°59'59.83"E N00°00'00.17"E N54°10'59.68"E N27°18'59.29"W N54°10'59.68"E N27°18'59.29"W S00°00'00.17"W N89°59'59.83"W N00°35'28.18"W N54°10'59.68"E S27°18'59.29"E S39°03'38.95"W S85°29'48.73"W CURVE TABLE CURVE C1 C2 C3 C4 C5 C17 C18 C19 DELTA 90°00'00" 54°11'00" 67°23'40" 14°06'19" 152°41'01" 40°40'09" 14°06'19" 24°43'10" RADIUS 20.00' 164.50' 20.00' 144.50' 20.50' 30.00' 154.50' 266.54' LENGTH 31.42' 155.56' 23.53' 35.57' 54.63' 21.29' 38.04' 115.00' BEARING N45°00'00"E N27°05'30"E N06°22'51"E N47°07'50"E S76°20'30"W N19°44'36"E N47°07'50"E S24°59'46"W CHORD 28.28' 149.83' 22.19' 35.48' 39.84' 20.85' 37.94' 114.11' B M KEYMAP G8 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G8 DETAILED GRADING PLAN 33 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES **All circled are line over text.** 3/03/2020 ZEPHYR RD ROSEN DRIVE PROPOSED STORM DRAIN 57.26 56.47 53.44 55.02 54.72 54.48 54.59 55.01 55.54 56.21 57.07 58.11 59.30 60.54 61.77 62.87 63.74 64.62 65.49 66.33 67.06 67.71 68.23 68.66 56.00 56.48 56.17 55.63 54.79 54.58 54.37 54.77 55.25 55.72 56.18 56.67 57.13 57.62 58.11 58.66 59.41 60.16 60.91 61.66 62.41 63.16 63.91 64.74 60.40 59.65 60.32 59.95 61.05 61.91 62.60 63.42 63.79 60.70 61.11 61.53 59.25 59.29 59.97 58.79 58.92 59.04 59.17 58.59 58.47 58.32 58.14 58.07 57.75 57.64 57.54 57.44 57.32 57.19 57.09 56.38 56.81 57.23 57.65 58.07 58.41 58.40 57.29 57.07 58.77 58.98 56.88 56.68 59.19 59.16 57.49 56.50 58.27 55.76 56.92 57.49 STORM DRAIN 3 SEE SHEET ST3 STORM DRAIN 2 SEE SHEET ST2 B FG=56.24 TF=56.91 LOT 6 A FG=66.93 TF=67.60 LOT 22 A FG=66.93 TF=67.60 LOT 21 A FG=65.43 TF=66.10 LOT 20 A FG=65.43 TF=66.10 LOT 19 A FG=63.93 TF=64.60 LOT 18 A FG=63.93 TF=64.60 LOT 17 A FG=62.43 TF=63.10 LOT 16 A FG=62.43 TF=63.10 LOT 15 A FG=60.99 TF=61.66 LOT 14 A FG=60.99 TF=61.66 LOT 13 T FG=59.92 TF=60.59 LOT 12 T FG=59.92 TF=60.59 LOT 11 B FG=58.97 TF=59.64 LOT 10 B FG=58.97 TF=59.64 LOT 9 B FG=57.39 TF=58.06 LOT 8 B FG=57.39 TF=58.06 LOT 7 B FG=56.24 TF=56.91 LOT 5 B FG=57.12 TF=57.79 LOT 4 B FG=57.12 TF=57.79 LOT 3 B FG=57.43 TF=58.10 LOT 2 B FG=57.43 TF=58.10 LOT 1 B FG=58.30 TF=58.97 LOT 1 B FG=58.30 TF=58.97 LOT 2 B FG=58.83 TF=59.50 LOT 3 B FG=58.83 TF=59.50 LOT 4 B FG=58.83 TF=59.50 LOT 5 B FG=58.83 TF=59.50 LOT 6 B FG=59.88 TF=60.55 LOT 1 B FG=59.88 TF=60.55 LOT 2 B FG=60.30 TF=60.97 LOT 3 B FG=60.30 TF=60.97 LOT 4 B FG=59.69 TF=60.36 LOT 10 B FG=59.69 TF=60.36 LOT 9 B FG=59.69 TF=60.36 LOT 8 B FG=59.69 TF=60.36 LOT 7 B FG=61.75 TF=62.42 LOT 10 B FG=61.75 TF=62.42 LOT 9 B FG=63.30 TF=63.97 LOT 8 B FG=63.30 TF=63.97 LOT 7 B FG=64.49 TF=65.16 LOT 6 B FG=64.49 TF=65.16 LOT 5 TRACT L DU&PAE B FG=58.06 TF=58.73 LOT 1 B FG=58.87 TF=59.54 LOT 2 57.56 59.19 56.89 58.47 60.49 61.93 63.43 64.93 66.43 62.80 61.25 58.33 57.80 59.38 56.62 55.74 59.42 24' FL-FL 18.58' FL-EOC 1' RIBBON CURB 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 2' CONCRETE PAN 20' PROPOSED DRIVE-OVER CURB AND GUTTER 2.0% 1.7% 55.10 58.53 59.08 0.8% 1.3% 3.0% 2.0% 2.0% 1.5% 1.5% 57.09 57.15 57.26 57.32 54.96 55.20 56.11 57.59 58.71 58.73 59.42 58.23 58.69 57.73 64.56 60.16 60.91 61.66 62.41 63.16 63.91 58.15 57.33 57.15 57.22 57.34 58.06 57.71 57.71 0.4% 0.4% 0.4% 0.1% 0.6% 1.9% 0.8% 57.55 2.2% 2.2% 2.6% 2.2% 0.6% 0.8% 0.8% 0.8% 0.8% 64.46 57.37 54.73 55.26 57.04 56.94 57.03 20.00' EOC-FL 20.00' EOC-EOC 24.00' FL-FL 18.58' FL-EOC 56.24 56.27 56.42 56.39 53.20 55.07 54.94 52.79 54.64 54.75 1.5% 17.0% 15.9% 19.6% 17.4% 3.5% 3.6% 1.5% 3.0% 2.0% 4.5% 25.1% 25.1% 59.78 60.52 61.27 62.02 62.77 63.52 64.27 2.0% 2.3% 2.1% 2.0% 1.5% 1.5% 2.2% 1.8% 1.3% 2.2% 1.1% 2.2% 2.3% 2.2% 2.3% 2.2% 2.2% 2.0% 2.0% 2.0% 2.0% 56.83 LINE TABLE LINE L14 L19 L20 L22 L23 L26 L27 L29 L30 L31 L32 L33 L34 L35 L39 LENGTH 194.24' 150.43' 153.58' 59.00' 214.49' 91.53' 192.78' 171.17' 97.12' 9.19' 11.38' 173.58' 256.42' 237.03' 120.03' BEARING N00°01'01.94"E S89°58'58.06"E N89°58'58.06"W S00°01'01.94"W S89°43'21.16"W S00°01'01.94"W N00°01'02.90"E N89°43'21.16"E N89°58'58.06"W S45°01'01.94"W N89°58'58.06"W S89°58'58.06"E N00°01'01.94"E S89°43'21.16"W S00°01'01.94"W CURVE TABLE CURVE C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 DELTA 105°26'27" 39°22'44" 14°43'33" 110°27'16" 90°00'00" 54°31'30" 35°10'49" 89°42'17" 14°47'56" 39°43'34" 35°10'49" RADIUS 30.00' 218.00' 65.00' 15.00' 15.00' 236.58' 83.58' 30.00' 125.00' 228.00' 75.00' LENGTH 55.21' 149.83' 16.71' 28.92' 23.56' 225.14' 51.32' 46.97' 32.29' 158.08' 46.05' BEARING N52°42'11"W S54°53'13"W S27°50'05"W S34°45'20"E S45°01'02"W S62°27'36"W S17°36'26"W N44°52'12"E S82°19'23"W S55°03'38"W S17°36'26"W CHORD 47.74' 146.90' 16.66' 24.64' 21.21' 216.74' 50.52' 42.32' 32.20' 154.94' 45.33' Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 G7 DETAILED GRADING PLAN 32 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH B M KEYMAP LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1 WHEN NOT IN USE. 8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS. 9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK ALONG DITCH LATERAL. 10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT. 11. DRIVEWAY ACCESS FOR BLOCK 7, LOT 1 AND BLOCK 6, LOT 11 SHALL BE RESTRICTED TO DANCING CATTAIL DRIVE. 12. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. 36.25 (36.25) 2.0% NOTES: PROPOSED SLOPES EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES G7 **All circled are line over text.** 3/03/2020 UD UD UD UD S S S S S S S S S S S S S S S S S S S S S S S S S S S S W W W W W W W W W W W W W W W W W W W W W W W W W W UD UD UD UD UD UD UD UD UD UD UD UD S W S W W W E LEC E ELEC BRKR X X X X X X X X X X FO FO FO FO FO FO FO FO FO E E E E E E E E E MISTY MEADOW DR FALLEN BRANCH DR SDCO 4-2 STA 13+92.35 N: 101337.76 E: 203384.21 SDCO 4-4 w/ 45° BEND STA 12+27.37 N: 101465.30 E: 203247.32 SDCO 4-6 STA 12+27.37 N: 101676.41 E: 202856.48 SDCO 4-11 STA 10+47.70 N: 101575.14 E: 202672.20 11.25° BEND 4-10 STA 10+82.28 N: 101606.78 E: 202688.72 22.5° BEND 4-9 STA 11+02.44 N: 101622.51 E: 202701.37 22.5° BEND 4-8 STA 12+01.93 N: 101673.15 E: 202793.89 11.25° BEND 4-7 STA 12+27.37 N: 101678.00 E: 202838.60 11.25° BEND 4-5 STA 12+27.37 N: 101486.80 E: 203219.85 45° BEND 4-3 STA 12+27.37 N: 101454.52 E: 203248.64 HORIZ DEFLECTION STA 12+27.37 N: 101420.69 E: 203291.88 22.5° BEND 4-1 STA 13+99.60 N: 101331.68 E: 203401.46 38.50 LF 8" PERF. PVC @ 0.50% 18.29 LF 8" PERF. PVC @ 0.50% 124.11 LF 8" PERF. PVC @ 0.50% 54.90 LF 8" PERF. PVC @ 0.50% 10.86 LF 8" PERF. PVC @ 0.50% 34.89 LF 8" PERF. PVC @ 0.50% 409.86 LF 8" PERF. PVC @ 0.50% 17.95 LF 8" PERF. PVC @ 0.50% 44.97 LF 8" PERF. PVC @ 0.50% 105.47 LF 8" PERF. PVC @ 0.50% 20.19 LF 8" PERF. PVC @ 0.50% 35.69 LF 8" PERF. PVC @ 0.50% LOT 1 LOT 2 LOT 8 LOT 6 LOT 5 LOT 7 LOT 12 LOT 16 LOT 15 LOT 14 LOT 13 LOT 10 LOT 11 LOT 9 LOT 13 LOT 14 LOT 9 LOT 10 LOT 11 LOT 12 LOT 7 LOT 8 36' FL-FL 30' EASEMENT REC. NO. 20110070565 67' EASEMENT REC. NO. 20140004033 6' UTILITY EASEMENT PROPERTY BOUNDARY (TYP.) EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE SDCO 4 STA 10+00.00 N: 101305.95 E: 203430.11 PROPOSED 8" WATER 59' ROW 9' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 1 LOT 2 LOT 6 LOT 3 LOT 5 LOT 4 LOT 17 BLOCK 11 SANITARY SEWER LINE 1 SEE SHEET SS2 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 19+75 19+00 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 SDCO 4-2 STA 10+56.80 RIM 4973.4± INV. IN 4948.74 (NW) INV. OUT 4948.74 (E) SDCO 4-4 STA 12+46.66 RIM 4971.3± INV. IN 4949.68 (NW) INV. OUT 4949.68 (S) SDCO 4-6 STA 16+91.41 RIM 4970.2± INV. IN 4951.90 (W) INV. OUT 4951.90 (SE) SDCO 4-11 STA 19+15.69 RIM 4964.4± INV. OUT 4953.02 (NE) 11.25° BEND 4-10 STA 18+80.00 INV. 4952.84 (SW) 22.5° BEND 4-9 INV. 4952.84 (NE) STA 18+59.81 INV. 4952.74 (SW) INV. 4952.74 (NE) 22.5° BEND 4-8 STA 17+54.34 INV. 4952.21 (SW) INV. 4952.21 (E) 11.25° BEND 4-7 STA 17+09.37 INV. 4951.99 (W) INV. 4951.99 (E) 11.25° BEND 4-5 STA 12+81.55 INV. 4949.85 (NW) INV. 4949.85 (SE) 45° BEND 4-3 STA 12+35.80 INV. 4949.63 (N) INV. 4949.63 (SE) HORIZ DEFLECTION STA 11+80.90 INV. 4949.36 (NW) INV. 4949.36 (SE) 22.5° BEND 4-1 STA 10+38.50 INV. 4948.65 (W) INV. 4948.65 (SE) 38.50 LF 8" PERF. PVC @ 0.50% 18.29 LF 8" PERF. PVC @ 0.50% 124.11 LF 8" PERF. PVC @ 0.50% 54.90 LF 8" PERF. PVC @ 0.50% 10.86 LF 8" PERF. PVC @ 0.50% 34.89 LF 8" PERF. PVC @ 0.50% 409.86 LF 8" PERF. PVC @ 0.50% 17.95 LF 8" PERF. PVC @ 0.50% 44.97 LF 8" PERF. PVC @ 0.50% 105.47 LF 8" PERF. PVC @ 0.50% 20.19 LF 8" PERF. PVC @ 0.50% 35.69 LF 8" PERF. PVC @ 0.50% SDCO 4 STA 10+00.00 RIM 4973.3± INV. IN 4948.46 (NW) INV. IN 4948.46 (SE) INV. OUT 4948.46 (SW) PROPOSED GROUND EXISTING GROUND 8" PVC WATER STA.=10+10.00 TOP=4968.60 Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 PRIVATE SUBDRAIN LINE 1-4 NORTH EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORMLINE LEGEND: NOTES: W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED UNDERDRAIN EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE RIGHT OF WAY PROPERTY BOUNDARY S PROPOSED SEWER SERVICE W PROPOSED RESIDENTIAL WATER SERVICE PROPOSED SUBDRAIN UD SD EXISTING FIRE HYDRANT PROPOSED STORMLINE LIMITS OF DEVELOPMENT LOD EASEMENT LINE 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4. WATER SERVICE MUST HAVE MINIMUM OF 4.5' COVER AND MINIMUM OF 18" VERTICAL CLEARANCE FROM STORM SEWER. ANY STORM SEWER SHALLOWER THAN 5.0' WILL REQUIRE THE WATER SERVICE TO BE INSTALLED UNDER THE PROPOSED STORM SEWER. 5. STORM DRAIN PIPE JOINTS SHALL NOT BE LOCATED OVER UTILITY CROSSINGS. 6. PRIVATE STORM SEWER MATERIAL MAY BE RCP, PVC OR HDPE. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. HDPE MUST BE SMOOTH WALLED INTERIOR. HDPE FITTINGS MAY BE USED FOR PVC INSTALLATIONS. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 7. AREA DRAIN PIPE AND DRAIN BASIN CONNECTIONS TO RCP STORM SHALL USE INSERTA TEE OR APPROVED EQUAL FOR CONNECTION. B M KEYMAP PROFILE SCALE: SD2 PLAN AND PROFILE SUBDRAIN LINE 1-4 24 SD1 SD2 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Line Over Text 3/03/2020 Y D H Y D W TELE VAULT ELEC VAULT ELEC VAULT ELEC VAULT ELEC H Y D S S S ELEC E ELEC BRKR OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS SS SS SS SS LID VAULT F.O. W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E T T T T T T T T T T T G G G G G G T T T W W W W W W W PLANNED TEMP. FH ASSEMBLY TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING WALL TO BE REMOVED EXISTING F/O TO REMAIN EXISTING ELECTRIC TO REMAIN 15' EASEMENT REC. NO. 20140004033 30' EASEMENT REC. NO. 20140004033 EXISTING FENCE TO BE REMOVED 15' EASEMENT REC. NO. 20110070565 EXISTING TELEPHONE LINE TO REMAIN EXISTING FENCE TO BE REMOVED EXISTING FENCE TO REMAIN EXISTING ELECTRIC BREAKER TO REMAIN 30' EASEMENT REC. NO. 20110070565 67' EASEMENT REC. NO. 20140004033 EXISTING FENCE TO REMAIN 60' EASEMENT REC. NO. 20100010642 15' EASEMENT REC. NO. 20110070565 EXISTING 24" CMP STORM TO BE REMOVED PLANNED FIRE HYDRANT TO REMAIN EXISTING SANITARY MANHOLE TO REMAIN EXISTING 12" PVC SANITARY EXISTING FIRE HYDRANT TO REMAIN EXISTING 12" PVC WATER EDGE OF WETLAND EXISTING GRAVEL ROAD TO BE REMOVED PLANNED 8" PVC WATER 50' DITCH BUFFER FROM TOP OF BANK PLANNED 10" PVC SANITARY PLANNED 20' GRAVEL ROAD TO REMAIN PLANNED 30' SFCSD EASEMENT PLANNED TEMP. FIRE HYDRANT TO REMAIN PLANNED HANSEN FARM PLANNED 24"x36" RCBC BURLEY TREE DR KNOBBY PINE DR FALLEN BRANCH DR FLOATING LEAF DR ROSEN DRIVE DITCH LATERAL 59' ROW 36' FL-FL PLANNED PEDESTRIAN BRIDGE (SEE HANSEN FARM UTILITY PLANS) 50' DITCH BUFFER FROM TOP OF BANK 54' FL-FL 76' ROW PLANNED END OF ROAD SIGNS TO BE REMOVED PLANNED HANSEN FARM EXISTING TEMPORARY FIRE HYDRANT TO BE REMOVED 15' EASEMENT REC. NO. 20140004033 EXISTING OVERHEAD ELECTRIC TO BE UNDERGROUND OR REMOVED PER UTILITY PROVIDER UNION PACIFIC RAILROAD EXISTING EDGE OF WATER AT TIME OF SURVEY EXISTING 36" IRON PIPE TO REMAIN PROJECT BOUNDARY (TYP.) RED WILLOW DRIVE EXISTING TOP OF DITCH BANK EXISTING TOP OF DITCH BANK 100' WETLAND BUFFER EXISTING CELL TOWER SITE TO REMAIN. CONTRACTOR TO PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS FROM PUBLIC ROW. EXISTING CONCRETE CROSS-PAN AND CURB RETURN TO BE REMOVED X X X X X X X EXISTING FENCE TO REMAIN EXISTING CONCRETE IRRIGATION STRUCTURE UNION PACIFIC RAILROAD MAIL CREEK DITCH DITCH LATERAL PROPERTY BOUNDARY (TYP.) PLANNED HANSEN FARM EXISTING TOP OF DITCH BANK 50' DITCH BUFFER FROM TOP OF BANK FO FO FO FO E E E EXISTING GRAVEL ROAD TO BE REMOVED PLANNED TEMPORARY FIRE HYDRANT TO BE REMOVED PLANNED 8" WATERLINE TO REMAIN 59' ROW 36' FL-FL EXISTING FIBER OPTIC AND ELECTRIC LINES TO REMAIN 30' EASEMENT REC. NO. 20140004033 15' EASEMENT REC. NO. 20110070565 PLANNED 24"X36" RCBC AND CONCRETE HEADWALL OHU OHU OHU OHU OHU FO FO FO FO FO T T T T T 15' OPTION AND LAND LEASE AGREEMENT EASEMENT REC. NO. 20140004033 PLANNED 24"X36" RCBC AND CONCRETE HEADWALL 76' ROW 54' FL-FL EXISTING GRAVEL ROAD TO BE REMOVED EXISTING FIBER OPTIC AND ELECTRIC LINES TO REMAIN EXISTING OVERHEAD ELECTRIC TO BE UNDERGROUND OR REMOVED PER UTILITY PROVIDER PLANNED TEMPORARY CONSTRUCTION EASEMENT Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 EX1 AND DEMOLITION PLAN EXISTING CONDITIONS 3 NORTH EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7. ALL IMPROVEMENTS LABELED AS "PLANNED" ARE A PART OF THE HANSEN PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE FOUND IN THE HANSEN FARM UTILITY PLANS. 8. THE CONTRACTOR SHALL PROVIDE 24 HOUR 7 DAYS A WEEK ACCESS TO THE CELL TOWER FROM PUBLIC ROW. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) APPROXIMATE LIMITS OF CONCRETE/ ASPHALT REMOVAL OR MILL & OVERLAY 1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONES. NATURAL HABITAT BUFFER ZONES B M KEYMAP MATCHLINE-THIS SHEET MATCHLINE-THIS SHEET CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Line Over Text 3/03/2020 Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 BENCHMARK 2-02 EAST SIDE OF TIMBERLAND ROAD, 1/2 MILE NORTH OF TRILBY ROAD, ON THE MIDDLE CONCRETE PAD TO AN ELECTRIC BOX. ELEVATION: 4964.37 BENCHMARK 16-01 SOUTH SIDE OF WILLOW SPRINGS WAY APPROX. 50 FT. WEST OF THE INTERSECTION OF WILLOW SPRINGS WAY AND TIMBERLINE ROAD ON THE SOUTHWEST CORNER OF A STORM INLET. ELEVATION: 4956.98 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.19' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE EAST LINE OF THE NORTHEAST QUARTER OF SECTION 7, AS BEARING SOUTH 00'00'53" EAST (ASSUMED BEARING) AS MONUMENTED ON PLAT. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: N/A CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Final Drainage and Erosion Control Report for Rennat Subdivision dated Februaru 12, 2020 by Northern Engineering Services, Inc., shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline construction shall conform to the Fort Collins-Loveland Water District Standard Construction Specifications current at the date of construction. 2. All sanitary sewer construction shall conform to the South Fort Collins Sanitation District Standard Construction Specifications current at the date of construction. 3. The contractor shall maintain a minimum of 10 feet of horizontal separation and 18 inches of vertical separation between all sewer and water lines. 4. Minimum depth of cover over water mains shall be 5.0 feet and maximum cover shall be 6.0 feet. 5. Manhole rim elevations are to be adjusted to 1/4" below finished grade. If necessary, cone sections shall be rotated to prevent lids being located within bicycle or vehicle wheel paths. 6. The size, type and location of all known underground utilities are approximate when shown on these drawings. It shall be the responsibility of the contractor to verify the existence of all underground utilities in the area of the work. Before commencing new construction, the contractor shall be responsible for locating all underground utilities and shall be responsible for all unknown underground utilities. 7. All water fittings and valves are only graphically represented and are not to scale. CS2 CONSTRUCTION NOTES GENERAL AND 2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 See Sheet CS1. 3/03/2020 FROM FACE OF WALK 6.5' MIN FENCE SETBACK FROM FACE OF WALK 3' MIN FENCE SETBACK FROM CURB FLOWLINE 3' MIN FENCE SETBACK FROM EDGE OF ALLEY · ZEPHYR RD · MISTY MEADOW DR · DANCING CATTAIL DR · CROAKING TOAD DR · FALLEN BRANCH DR · AUTUMN BREEZE CT CONCRETE PAVEMNET 9' UTIL. 59' ROW ESMT. 9' UTIL. ESMT. LOCAL CONNECTOR 8' PARKING 8' PARKING 10' TRAVEL LANE 6.5' PKWY TBC-WALK 36' - 10' TRAVEL LANE 4.5' WALK 4.5' WALK 30" VERTICAL CURB & GUTTER 30" VERTICAL CURB & GUTTER 6.5' PKWY TBC-WALK · FLYING MALLARD DR · WINDY WILLOW DR · ALLEY 1 · ALLEY 2 12' TRAVEL LANE 24' - 12' TRAVEL LANE 8' UTIL. ESMT. 8' UTIL. ESMT. ALLEY (PRIVATE) CS1 COVER SHEET 1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R FEBRUARY 2020 PROJECT LOCATION VICINITY MAP NORTH I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: Northern Engineering Services, Inc. Project No. 1204-003 Date: February 19, 2019 ORIGINAL FIELD SURVEY BY: CONTACT INFORMATION PROJECT TEAM: Danny Weber, PE Northern Engineering Services, Inc. 301 North Howes Street, Sutie 100 Fort Collins, Colorado 80521 (970) 221-4158 Bob Tessely, PLS Northern Engineering Services, Inc. 301 North Howes Street, Sutie 100 Fort Collins, Colorado 80521 (970) 221-4158 CONTACT INFORMATION PROJECT TEAM: JD Padillla Post Modern Development 144 North Mason St., Suite 4 Fort Collins, Colorado 80524 (970) 407-7808 SHEET INDEX ENGINEER ING N O R T H E RN ENGINEER ING N O R T H E RN UTILITY CONTACT LIST: * UTILITY COMPANY PHONE NUMBER 1 CS1 COVER SHEET 2 CS2 GENERAL AND CONSTRUCTION NOTES 3 EX1 EXISTING CONDITIONS AND DEMOLITION PLAN 4 PH1 PHASING PLAN UTILITY SHEETS 5 OU1 OVERALL UTILITY PLAN 6-8 U1-U3 UTILITY PLAN SANITARY SHEETS 9-10 SS1-SS2 SANITARY SEWER LINE 1 PLAN AND PROFILE 11-12 SS3-SS4 SANITARY SEWER LINE 2 PLAN AND PROFILE 13 SS5 SANITARY SEWER LINE 2-2 PLAN AND PROFILE 14 SS6 SANITARY SEWER LINE 2-4 PLAN AND PROFILE 15 SS7 SANITARY SEWER LINE 2-5 PLAN AND PROFILE 16 SS8 SANITARY SEWER LINES 2-6 & 3 PLAN AND PROFILE 17 SS9 SANITARY SEWER LINES 3-1 & 3-3 PLAN AND PROFILE STORM SHEETS 18 ST1 STORM DRAIN LINE 1 PLAN AND PROFILE 19 ST2 STORM DRAIN LINE 2 PLAN AND PROFILE 20 ST3 STORM DRAIN LINES 3 & 4 PLAN AND PROFILE 21 ST4 STORM DRAIN LINES 5 & 6 PLAN AND PROFILE 22 ST5 STORM DRAIN LINE 7 & 8 PLAN AND PROFILE 23 SD1 SUBDRAIN LINE 1 PLAN AND PROFILE 24 SD2 SUBDRAIN LINE 1-4 PLAN AND PROFILE GRADING SHEETS 25 OG1 OVERALL GRADING PLAN 26-31 G1-G6 GRADING PLAN 32-33 G7-G8 DETAILED GRADING PLAN ROADWAY SHEETS 34-36 R1-R3 MISTY MEADOW DR PLAN AND PROFILE 37 R4 DANCING CATTAIL DR PLAN AND PROFILE 38 R5 DANCING CATTAIL DR & WINDY WILLOW DR PLAN AND PROFILE 39-40 R6-R7 CROAKING TOAD DR PLAN AND PROFILE 41 R8 FLYING MALLARD DR PLAN AND PROFILE 42 R9 FALLEN BRANCH DR PLAN AND PROFILE 43 R10 ALLEY 1 PLAN AND PROFILE 44 R11 ALLEY 2 PLAN AND PROFILE 45-46 R12-R13 ZEPHYR RD PLAN AND PROFILE 47 R14 ZEPHYR RD STRIPING PLAN 48 R15 SIGNAGE PLAN 49-51 INT1-INT3 INTERSECTION DETAILS 52-53 XS1-XS2 ZEPHYR ROAD CROSS SECTIONS DRAINAGE SHEETS 54 DR1 DRAINAGE EXHIBIT 55 EC1 EROSION CONTROL PLAN 56-57 EC2-EC3 EROSION CONTROL DETAILS DETAIL SHEETS 58-59 D1-D2 UTILITY DETAILS 60-62 D3-D5 DRAINAGE DETAILS 63 D6 GRADING DETAILS 64-66 D7-D9 SITE DETAILS A TRACT OF LAND LOCATED IN THE EAST HALF OF SECTION 7, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO RENNAT SUBDIVISION UTILITY PLANS FOR OWNER/APPLICANT SITE ENGINEER SURVEYOR GAS----------------- Xcel Energy-----------------------------------Stephanie Rich (970) 225-7857 ELECTRIC-------- City of Fort Collins Light & Power------- Austin Kreager (970) 224-6152 CABLE------------- Comcast--------------------------------------- Don Kapperman (970) 567-0245 TELECOM-------- CenturyLink Local Network--------------- William Johnson (970) 377-6401 WATER------------ Fort Collins-Loveland Water District---- Jay East (970) 226-3104 WASTEWATER- South Fort Collins Sanitation District--- Jay East (970) 226-3104 STORMWATER- City of Fort Collins Utilities---------------- Wes Lamarque (970) 416-2418 * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. Cathy Mathis TB Group 444 Mountain Avenue Berthoud, Colorado 80513 (970) 532-5891 PLANNER/ LANDSCAPE ARCHITECT PROJECT DATUM: NAVD88 BENCHMARK 2-02 EAST SIDE OF TIMBERLAND ROAD, 1/2 MILE NORTH OF TRILBY ROAD, ON THE MIDDLE CONCRETE PAD TO AN ELECTRIC BOX. ELEVATION: 4964.37 BENCHMARK 16-01 SOUTH SIDE OF WILLOW SPRINGS WAY APPROX. 50 FT. WEST OF THE INTERSECTION OF WILLOW SPRINGS WAY AND TIMBERLINE ROAD ON THE SOUTHWEST CORNER OF A STORM INLET. ELEVATION: 4956.98 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.19' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE EAST LINE OF THE NORTHEAST QUARTER OF SECTION 7, AS BEARING SOUTH 00°00'53" EAST (ASSUMED BEARING) AS MONUMENTED ON PLAT. PROJECT BENCHMARKS: All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT Sheet RENNAT SUBDIVISION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 66 The East Line is not do not match the titles on these sheets. 3/03/2020 The East Line is not referenced on the Subdivision Plat.