HomeMy WebLinkAboutBEST BUY EXPANSION MAJOR AMENDMENT AND REPLAT - 29 92B - CORRESPONDENCE - STAFF'S PROJECT COMMENTS (2)Commu: ./ Planning and Environmental vices Current Planning City of Fort Collins February 23, 2000 Mr. Andrew Golland MBH Architects 1115 Atlantic Avenue Alameda, CA 94501 Dear Andrew: Staff has reviewed the request for Best Buy Major Amendment and offers the following comments: 1. We are very concerned about the proposed architectural design of the building, especially the front (west) elevation with the large blue metallic/synthetic stucco wedge, and accompanying blue/black accents, as the prominent feature. As we stated in our Conceptual Review letter dated September 27, 1999 to Sarah Noori (MBH) and in two separate subsequent follow-up meetings with Mike Klein (Best Buy) and Andrew Golland (MBH), the Planning Department will not support such a radical departure from the established character of The Marketplace P.U.D. shopping center. The City of Fort Collins Land Use Code states: "Building and design shall contribute to the uniqueness of a zone district, and/or the Fort Collins community with predominant materials, elements, features, color range and activity areas tailored specifically to the site and its context. A standardized prototype design shall be modified if necessary to meet the provisions of this Land Use Code." "Building materials shall either be similar to the materials already being used in the neighborhood or, if dissimilar materials are being proposed, other characteristics such as scale and proportions, form, architectural detailing, color and texture, shall be utilized to ensure that enough similarity exists for the building to be compatible despite differences in materials. " A large blue wedge roof element does not appear anywhere else in the center. Its incorporation will cause the Major Amendment to fall out of compliance with the Land Use Code and not be allowed. Please note that the exact same comment was made several years ago to your competitor 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020 as it sought a location in a nearby center. Just as Circuit City did not get their giant "red plug" entrance, so to Best Buy shall modify its design accordingly. We look forward to working with architectural professionals at MBH in finding a creative solution that allows Best Buy some tasteful identification but within the context of its surroundings. 2. Similarly, "Blue Dryvit Panzer Mesh" and black painted c.m.u. shall not be used as a fagade treatment. This area should be a c.m.u. to remain consistent with the established repetitive pattern across the fagade and in compliance with the other fagade requirements of the Land Use Code as discussed below. 3. The north facade and a portion of the east fagade do not comply with the Variation in Massing standard which states: "A single, large dominant building mass shall be avoided in new buildings and, to the extent reasonably feasible, in development projects involving changes to the mass of the existing buildings. (1) Horizontal masses shall not exceed a height. -width ratio of 1:3 without substantial variation in massing that includes a change in height and projecting or recessed elements. (2) Changes in mass shall be related to entrances, the integral structure and or the organization of interior spaces and activities and not merely for cosmetic effect. False fronts or parapets create an insubstantial appearance and are prohibited." These two facades need to be revised to comply with this standard. Also, it appears from the site plan that the west fagade does not comply unless information can be provided regarding the depth of the recess at the entrance and the length of this recess. 4. Also, the proposed addition to the existing building does not comply with the following fagade detail standards: "Fagade Treatment. Minimum Wall Articulation. Building bays shall be a maximum of thirty (30) feet in width. Bays shall be visually established by architectural features such as columns, ribs or pilasters, piers and fenestration pattern. In order to add architectural interest and variety and avoid the effect of a single, long or massive wall with no relation to human size, the following additional standards shall apply. 1. No wall that faces a street or connecting walkway shall have a bland, uninterrupted length exceeding thirty (30) feet without including at least two (2) of the following: change in plane, change in texture or masonry pattern, windows, treillage with vines, or an equivalent element that subdivides the wall into human scale proportions. 2. Side or rear walls that face walkways may include false windows and door openings defined by frames, sills and lintels, or similarly proportioned modulations of the wall, only when actual doors and windows are not feasible because of the nature and use of the building. " 5. Finally, in terms of architectural compliance, the building fails to comply with the standard requiring a "recognizable top." This standard states: "Base and Top Treatments. All facades shall have: A recognizable "top" consisting of (but not limited to): 1. comice treatments, other than just colored "stripes or "bands," with integrally textures materials such as stone or other masonry or differently colored materials; 2. sloping roof with overhangs and brackets, 3. stepped parapets." As we have discussed, there is a wide variety of solutions to providing a recognizable "top" to the new sections of the building. Again, we look forward to working creatively with the design team to find a way to meet the code provision. 6. The Major Amendment includes the construction of additional parking for a new total of 203 spaces. Based on the new building total square footage of 42,769, the amount of parking equates to 4.75 spaces per 1,000 square feet. This exceeds the allowable maximum parking ratio for retail stores of 4.00 spaces per 1,000 sq. ft. Therefore, the plan has an excess of 32 parking spaces. 3 Parking should be reduced to comply with the standard or a Modification of Standard should be submitted. Enclosed please find the pertinent Land Use Code section for the Modification procedure. Please note under (H) Step 8 (Standards), you will find the applicable review criterion that the Planning and Zoning Board will use by which to evaluate the Modification of Standard request. The applicable criterion requires a compare and contrast analysis. A successful Modification of Standard request must follow these steps. A. Prepare a Site Plan that meets the standard. B. Compare/contrast this plan with the plan you are proposing. C. Demonstrate how the proposed plan is at least equal to or better than the plan that meets the standard. This exercise requires more than just stating "this is what we want" or "we need this much parking" or "this is our standard program and it's what we do in most other cities." This type of reasoning will not be successful. Rather, it is extremely important to demonstrate how the proposed plan exceeds what is otherwise required by the Land Use Code. The test for your Modification of Standard is that the proposed plan must be found to be "better than would a plan which complies with the standard for which a modification is requested." Staff, therefore recommends the following areas where the plan could be upgraded above and beyond what the Code would otherwise require: A. Provide a north building entrance or otherwise exceed the architectural requirements. B. Upgrade the landscaped area northeast of the store with such features as a picnic pavilion or gazebo, benches, planters with seat walls, picnic tables, and trash containers, and low level pedestrian lighting. C. Add covered arcades across the north and west elevations with decorative columns and sloping metal roof. These suggestions are examples and not meant to be an exclusive list. The design team is encouraged to research other ideas for retrofitting strip shopping centers into areas featuring improved urban design and pedestrian amenities as found in a book entitled The New Urbanism — Toward an Architecture of Community, by Peter Katz, McGraw Hill, Inc., 1994. Again, for emphasis, the burden of proof for a Modification of a Standard is on the applicant to demonstrate how a plan exceeds the standards. 7. The proposed lighting, as shown on the Site Plan is excessive. Enclosed please find the pertinent sections of the Land Use Code. Please note that 4 walkways in commercial areas and parking areas are restricted to 0.9 and 1.0 foot-candles respectively. The 1,000 watt metal halide lights will not be allowed as this level of illumination would vastly exceed these limits. Please indicate which parking lot light fixtures are existing and which are proposed. New lighting should match the existing and not exceed. 8. Please note that the proposed floodlighting of the front elevation does not comply with fully shielding light sources. The standard states: "Light sources shall be concealed and fully shielded and shall feature sharp cut-off capability so as to minimize up -light, spill -light, glare and unnecessary diffusion on adjacent property." The floodlighting and 1,000 watt metal halide lamps must be eliminated. Parking lot lighting should match the balance of the center in both light source, wattage, fixture and pole. Foreground lighting at the entrance may be customized but shall illuminate in such a way as to not cause glare and must still feature down -directional, sharp cut-off fixtures. 9. Please describe the lighting levels anticipated for the truck dock area. Keep in mind that lighting levels in loading and unloading platforms may be increased to 20 foot candles but must remain shielded. 10. Please specify that the wall packs will be down -directional and feature sharp cut-off fixtures. 11. The sidewalk connecting J.F.K. Parkway to the outdoor plaza area should be detached from the curb by 6 — 8 feet and straight. A crosswalk should then be provided across the internal drive aisle to the sidewalk on the north side of the store. This will allow a more continuous and direct pedestrian connection from J.F.K. to the front entrance (or a north entrance, if provided). Shade trees (minimum two inch caliper deciduous) should be planted in the parkway strip on 30 foot centers. A separate connection should then be made into the plaza area. 12. Please provide a new sidewalk to the north along the west side of the new parking lot. The walk should be a minimum of six feet and detached. The parkway should feature street trees on 30 foot centers. Please provide a ramp and crosswalk at the north end so it aligns with the entrance to the Sportscaster restaurant. 13. Street trees on J.F.K. should be minimum two inch caliper deciduous shade trees planted on 30 foot centers. Shade trees must be kept 40 feet from existing public streetlights. This intervening space may be treated with 1.5 inch caliper ornamental trees that can be no closer than 15 feet from public streetlights. The Landscape Plan indicates Crabapples along 5 J.F.K that are used as street trees that should be upgraded to shade trees. Please show where the existing public streetlights are located so the street tree plantings can be evaluated accordingly. 14. Please show the accurate number of trees on south property line next to Savers. 15. There should be no gaps in the shrub bed along the truck dock screen wall. Please add plant material so that the landscaping is continuous along both the east and north sides of this wall. Be sure to mix evergreen with deciduous. 16. With 203 parking spaces, seven handicap parking stalls are required but only five are shown. Please add two. 17. Please provide a detail of the truck dock screen wall on one of the Landscape sheets. Please indicate where the pallets and miscellaneous outside storage (discarded shopping carts, shelving, racking, dumpsters, etc.) will be stored. Please state that these elements will not be visible from J.F.K. Parkway. There needs to be sufficient room for delivery trucks as well as miscellaneous storage. (Presently, pallets and discarded materials are dumped outside the northeast corner of the store and are visible.) 18. Please indicate that the bike rack near the front entry exists. 19. Staff is concerned about the proposed monument sign along J.F.K. Please provide a detail of the pedestal and specify that the material is to match the predominant building exterior c.m.u., the split face block. The overall height of the pedestal and sign should not exceed eight feet so as to not compete or interfere with the canopies of the street trees. The pedestal should match the one on South College which does a nice job of matching the building. 20. Please re -label the sheets so that sheet AS-1 is sheet 1 of 4, L1 is 2 of 4, L2 is 3 of 4, and A-6 is 4 of 4. 21. The following comments apply to sheet AS-1: A. This sheet is considered the cover sheet. It should have a large title in the lower right corner. B. Please provide an Ownership signature block with a Notary block. C. Please provide a City Approval block. R D. Please provide a legal description. E. Please provide a legend. F. Please add the standard notes (see attached). G. Please provide an Index to Sheets. H. Please expand the Project Data (use the approved P.U.D. as a guide). I. Please create a document that scales correctly and is not a reduction. This sheet does not scale as indicated. J. Please show the location of the two existing curb cuts on the east side of J.F.K. Parkway on the Postal Service site. K. , Please indicate which sidewalks are existing and which are proposed. Show the walk on the south connecting to Savers. L. Please indicate which parking stalls are existing and which are proposed. M. Please indicate a "typical' parking stall dimension. N. Please label the number of parking spaces per row. O. On the new parking lot, please provide the dimensions of the stalls and width of drive aisles. Note that the one-way drive aisle on the east needs to be only 20 feet wide. P. Show the head -in parking behind the retail building in Fountainhead. Provide the dimensions of these stalls. If less than 19 feet in length, provide the dimension of the abutting sidewalk. Please note that the width of the private drive must be at least 24 feet wide. 22. The following comments apply to the two Landscape sheets: A. Please indicate all existing landscaping for the site and which is to remain, which is to removed, and which is to be transplanted. The transplanted Austrian Pines are indicated clearly. Are there other materials that will also be transplanted? The Landscape Plan does not make a clear distinction between existing and proposed plant material. 7 B. Please add the following notes to the Landscape Plan: "All plant material shall be installed or secured with an irrevocable letter of credit, performance bond, or other financial security acceptable to the City, for 125% of the value of the plant materials and labor, prior to issuance of a Certificate of, Occupancy." "Developer shall ensure that the Landscape Plan is coordinated with the plans done by other consultants so that the proposed grading, storm drainage, or other construction does not conflict nor preclude installation and maintenance of landscape elements on this plan." C. Please check the count of the Transplanted Austrian Pine. The schedule says 11 but the plan indicates 12. D. Please provide a continuous shrub bed along the north -facing parking stalls in the new parking lot. 23. The following comments apply to the Architectural Elevations, sheet A-6: A. The drawings do not scale as indicated due to the sheet being a reduction. Please provide accurate scale. B. Please remove signage from the building elevations. A separate review and permit will be required for signage. C. Please label which sections of each elevation is existing and new. D. Please label elevations west, east, south, north. E. Please add common colors to the material legend or provide color chips as we do not know what the brand name and numbers refer to. Based on the colored drawing, please label the glass area above the entry as storefront glazing with red colored mullions and that the wall packs are painted yellow. F. Where applicable, please label that the new c.m.u. is to "match existing." 24. Please find enclosed the comment sheet and redlined plans from the City Engineering, Stormwater, Water/Wastewater, Mapping and Drafting, Street Oversizing, and Transportation Planning Departments. 8 25. Please find enclosed the comment sheet and redlined Landscape Plans from the Department of Natural Resources. 26. Please find enclosed the comment sheet from Poudre Fire Authority. 27. Be sure to return all redlined plans. 28. On Wednesday, February 23, 2000, Staff conducted a site inspection of the premises. Missing from the site are two Autumn Purple Ash, two Ponderosa Pine, one Pinyon Pine, and numerous shrubs (see attached redlined Landscape Plan). Technically, the site is in violation of the approved P.U.D. Ratherthan write up a Zoning Violation, Staff would prefer to work with the applicant so that all plant material is restored, in accordance with the quantities indicated on the approved Landscape Plan, prior to issuance of a Certificate of Occupancy for the expansion. If the expansion effort fails to proceed to the Building Permit stage, Staff will initiate the Zoning Violation Notice. We recommend that the store manager begin negotiations with a reputable landscape contractor so that irrigation systems are checked so that restored plant material will thrive. The number of shrubs that are missing is surprisingly high and a faulty irrigation system could be the reason. (Also, the amount of discarded store material visibly exposed on the northeast corner of the building does not speak well for the image of the store.) This concludes Staff comments at this time. Please note that revised plans based on these comments must be received by the Planning Department within 90 days of the date of this letter. One 30-day extension may be granted upon request to the Planning Director. If these deadlines cannot be met, the Planning Director is authorized to remove the project from the development review system. As always, please feel free to contact our office if you have any questions or concerns regarding these comments, or to set up a meeting with the appropriate staff to discuss the issues in depth. Sincerely: Ted Shepard Chief Planner Enc. 6