HomeMy WebLinkAboutBEST BUY PUD PRELIMINARY - 29 92 - CORRESPONDENCE - STAFF'S PROJECT COMMENTSCommur Planning and Environmental vices
Planning Department
City of Fort Collins
May 21, 1992
Frank Vaught
Vaught -Frye Architects
1113 Stoney Hill Drive
Fort Collins, CO. 80525
Dear Frank,
Staff has reviewed your submittal for the Best Buy P.U.D._ -
Preliminary and has the following comments to offer:
1. The building envelope as shown on the Site Plan must be
dimensioned from the north and south property lines, similar
to the dimensions to South College Avenue and the east -
property line.
2. The flushwall sign on the front of the building, being the
sales tag .cabinet sign, cannot project above the roof line
(shown as the 34'-8" Above Finish Floor elevation).
3. The signs as shown will not meet the City sign code allowance.
This use is allowed -a maximum of 400 square feet of signage,
including the freestanding project I.D. sign.
4. The number of parking spaces as shown on the Site Plan is
excessive for the apparent use, creating a mass of asphalt
without much to soften and mitigate the amount of hard surface
on site. The 179 spaces as requested would equate to 112
parking spaces for customers (based on 4 spaces/1000 square
feet of general retail floor area) and 67 parking spaces for
100 employees (based on 2 parking spaces for each 3 employees
on the major shift of a commercial use, as per City Code) .
There are two comparisons of existing on -going businesses
with the same product line. The Fred Schmid building is
slightly larger in size and the site has a total of 46 parking
spaces. The SoundTrack building is slightly smaller in size
and the site has a total of 42 parking spaces. The
indiscrepancy of on-site,parking between this use and those
other two is not understood or acceptable. As a minimum, the
parking bays along South College Avenue and the south side of
the Best Buy building should be eliminated.
5. The distance between the center of the parking aisles should
be 621, not 60' as shown on the Site Plan.
281 North College Avenue • P.O. Box 580 0 Fort Collins, CO 80=2_2-0580 • (303) 221-6750
6. All easements will need to be shown on the subdivision plat
with dimensions locating them on the lot.
7. The development as planned proliferates the -use of JFK Parkway
as an "arterial alley" behind the centers in this area. Other
building locations might be considered thatwould allow
internal parking on this site, opening up the opportunity for
the Petersen property to the east to develop a unified. plan
with this use that could provide shared parking, pedestrian
interface between uses, better internal circulation on this
site, and good access to JFK Parkway. The vehicular connection
to the Fountainhead P.U.D. to the north looks awkward.
8. Dedication of 60' of street right-of-way from the section line
on South College Avenue or 161_from the flowline of the curb
& gutter on the east side, whichever is greater, will be
required with this request. A 15' utility easement outside of
the street right-of-way must be dedicated. Sidewalk easements
must be dedicated wherever -the sidewalk falls outside of the
street right-of-way. This information is required on the
subdivision plat.
9. The drive in front of the building should be 28' or 30' wide
instead of the 24' width as shown to -accommodate the movement
of delivery vehicles, especially if a car is parked along the
curb in front of the building. The drive at the northwest
corner of the building, adjacent to the landscape island, must
be kept at a constant width.
10. The deceleration lane taper conforming to the findings of the
traffic study should be added to the.Utility Plans.
11. There is an inconsistency between the Site Plan and the
Utility Drawings as to the alignment of the sidewalk along
South College Avenue. There must be a 9.5'-10' separation
between the back of curb and the sidewalk with a smooth
transition into the existing sidewalk on the Fountainhead
P.U.D. to the north.
12. Public Service has a 2" steel gas main in the Fountainhead
P.U.D., Phase 3 that is located 3' in from the west line of a
30' wide easement. This main presently stops 1' north of the
north line of this property. Public Service is requesting that
the access and utility easement as shown be widened to 30'
throughout to allow room for their gas main.
13. Public Service is requesting that the gas meter be located on
the north wall of the building if possible.
14. A copy of the comments from U.S. West is attached.
15. City Water/Wastewater comments have been returned to Parson's
& Associates on the Preliminary Utility Plans.
16. Water lines and fire hydrants must be provided with the
appropriate connections to existing water lines. Please
contact Poudre Fire Authority for their design information.
17. This building will very likely require fire sprinkler
protection. Poudre Fire Authority has not received information
on the proposed building contents so that they are able to
determine the specific fire protection requirements, if
needed.
18. Vehicular access connections to the adjacent developments must
be provided with appropriate easements.
19. There are at least two street trees shown in the parkway. along
South College Avenue that will have to be relocated to comply
with the ..City's tree/street light standard (please see
attachment).
20. A fescue blend sod for the turfgrass areas is being
recommended to allow for reduced water consumption.
21. Does the Preliminary Landscape Plan show all the existing
trees on this site? If not, please provide that information. _
22. The Stormwater Utility's comments are attached.
23. The City's parking ordinance requires bicycle and motorcycle
parking for uses that provide more than six parking spaces or
1,800 square feet of parking area. Bicycle parking has been
identified on the Site Plan but where is the motorcycle
parking intended to be?
24. A survey of the area within 150' of the proposal, exclusive of
public right-of-way, is to be shown on the Site -Plan as per
the submittal requirements. No information for the -properties
west of South College Avenue has been provided. Also, the
Vicinity Map should show the area surrounding the site within
a distance of at least one mile. This map covers a distance of
about 1,0001, and that only in the southerly direction.
25. How does the amount of open space compare with the adjacent
developments? It appears that this.site contains a lot of hard
surface area. The 18% open space as indicated on the Site Plan
seems somewhat high.
26. The pedestrian connections to South College Avenue and other
adjoining developments/properties is weak. The developer needs
to consider this project as being part of a larger "shopping
area" and provide the opportunity for customers to walk,
rather than drive, from development to development. What will
make the "possible sidewalk connection" to Phar-Mor a reality?
27. The Market Place and Fountainhead P.U.D.Is incorporate very
similar architectural elements, especially in the form of
building materials and color. The Best Buy building, as shown
on the preliminary elevations, is larger in scale than
anything in either of the two adjacent developments and does
not attempt to carry through any of the architectural elements
of those developments. The Business Service.Uses Point Chart
that was submitted is taking 6 points for being part of a
center, yet the site and building designs make this plan
strongly appear to be a freestanding use, with little
consideration for continuity to adjacent centers to the north.
and south.
28. The Best Buy building itself needs more horizontal relief,
. possibly in -the form of material or color bands. -
29. The width of the landscaped area along South College Avenue is
25-30 feet wide, compared to 35-40 feet in the Market Place
P.U.D. This buffer needs to -be increased. Generally, the
landscape plan is weak, with specific areas of concern being
the South College treatment, expansive parking without
landscape breaks, and lack of good foundation plantings &
buffering on the south and east sides of the building. Berming
and good selection of plant materials will help the South
College Avenue frontage. Who will be responsible for the
"selective removal of existing trees" on the site?
30. The lighting on this site will -be very critical to the overall
development of the area. The parking lot standards as shown
are about 33' in height. Do they match the existing standards
in the Market Place?. The proposed height seems excessive. The
building elevations reflect a lot of exterior wall mounted
lighting. More information is needed to evaluate the
intensity, coverage, and spillage of these lights.
31. The points earned on the .Business Service Uses Point Chart
included in the submittal appear to be acceptable. The earned
points are for being on a transit route, part of a center,
being two acres or more, utilizing joint parking, and
contiguity to existing urban development. The total is 32 of
54 maximum applicable points = 59%.
This concludes staff's comments at this time. Additional comments
may be forwarded to you as City departments and outside reviewing
agencies continue to review this request. .Please be aware of the
following deadlines to enable you to stay on schedule for the June
22, 1992 Planning and Zoning Board hearing:
Plan revisions due June 3, 1992 by 12:00 noon. Please contact me
for the number of each document to submit.
PMT's, renderings, revisions due June 15, 1992.
Final documents due June 18, 1992 by 12:00 noon.
I would like to meet with you as soon as possible to discuss these
comments. Please call me at 221-6750 to schedule a time that is
convenient for you.
Ie
erely,
e Olt
Project Planner
xc: Kerrie Ashbeck
Sherry Albertson -Clark..
Stormwater Utility
Transportation - -
file -
•
I0...
NF'
STATE OF COLORADO
DIVISION OF HIGHWAYS
4J�µt OF N
P.O. Box 850
Greeley, Colorado 80632-0850
(303) 353-1232 ".r ,8
� OF COLS
Larimer Co., S.H. 287
Best Buy PUD
NE Corner S.H. 287 and
Marketplace Access
May 8, 1992
Mr. Steve Olt, Planner
Planning Department
City of Fort Collins
P.O. Box 580
Fort Collins, CO 80522
Dear Mr. Olt:
We have reviewed the Best Buy PUD and we have the following comments:
Projected traffic on S.H. 287 indicates the need for a 140 foot total right
of way, 70 feet each side of the highway centerline. Since the existing
width along this property appears to be 53.7 feet east of the centerline,
J additional width to meet the projected need should be protected by reservation
or, preferably, dedication, as permitted by City regulations.
Consideration should be given to the construction of the full length deceleration
lane for the Fountainhead property as noted in the Traffic Study prepared
by Mr. Matt Delich, see pages 2 and 3. It is felt that the completion
of the deceleration lane and taper, to the length indicated in the State
Highway Access Code, would be beneficial to the safety and welfare of the
traveling public. Plans for this construction must be reviewed and approved
by this office prior to the actual construction. An access permit would
be necessary for this construction work within the right of way.
Thank you for the opportunity to review this proposal. Please contact
me at 350-2163 if you have any questions.
Very truly yours,
Evan A. Hoo r, F.
Development/Access Coordinator
EAH/cm
cc: L. D. Yost
J. F. Springer
File