Loading...
HomeMy WebLinkAboutWELLS FARGO PARKING LOT AND ATMS - MJA190003 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANS (2)PROPOSED GRADE R.O.W R.O.W 20.0' ROW 19.0' TRANSITION TO EXISTING SLOPE OF 1.21% LANDSCAPED AREA SCARIFY AND RECOMPACT SUBGRADE TO 95% MAX. 2" OF 1" DRY DENSITY MINUS ROCK 8" OF 1" CLEAN ROCK 6" OF FIBER REINFORCED CONCRETE EXISTING GROUND COVER SHEET C1.0 112 W. MAGNOLIA ST. PARKING 112 WEST MAGNOLIA STREET FORT COLLINS CO, 80525 SUPPLEMENTAL GENERAL NOTES: ABBREVIATIONS OWNER LEGAL DESCRIPTION BENCHMARK SURVEYOR 112 W. MAGNOLIA ST. PARKING MAJOR AMENDMENT OF FDP 180017 FOR 112 WEST MAGNOLIA STREET FORT COLLINS CO, 80525 CIVIL ENGINEER GEOTECHNICAL ENGINEER SYMBOL LEGEND NOVEMBER 2019 G G (UP) (UT) SS X WS WS WS SS R/W WS WS W R/W (OHP) 10.00 2.05% W FS E SHEET INDEX C1.0.... COVER SHEET C1.1.... GENERAL NOTES I C1.2.... GENERAL NOTES II C2.0.... DEMOLITION PLAN C3.0.... HORIZONTAL CONTROL AND UTILITY PLAN GENERAL NOTES I C1.1 112 W. MAGNOLIA ST. PARKING 112 WEST MAGNOLIA STREET FORT COLLINS CO, 80525 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL FOR BURIED UTILITY INFORMATION THREE (3) BUSINESS DAYS BEFORE YOU DIG CALL 811 (OR 1-800-922-1987) UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) WWW.UNCC.ORG R ENGINEERING & SURVEYING 4045 St. Cloud Drive, Suite 180 Loveland, CO 80538 [P] 970-622-2095 [F] 970-461-4469 5 6 4 5 2 FO VB S (OHP) (OHP) (OHP) (OHP) (OHP) (FO) (GAS) (FO) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) 5 6 4 5 2 FO VB S (OHP) (OHP) (OHP) (OHP) (OHP) (FO) (GAS) (FO) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (FO) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (GAS) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) SITE DETAILS C6.0 112 W. MAGNOLIA ST. PARKING 112 WEST MAGNOLIA STREET FORT COLLINS CO, 80525 CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL ENGINEERING & SURVEYING 4045 St. Cloud Drive, Suite 180 Loveland, CO 80538 [P] 970-622-2095 [F] 970-461-4469 DETAIL NOT TO SCALE SP-1 1' CONCRETE U-CHANNEL DETAIL NOT TO SCALE CATCH CURB SPILL CURB SP-2 18" CURB & GUTTER (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W EXISTING BUILDING MAGNOLIA STREET 20.0' ROW 18.81' PROPERTY LINE EXISTING STORM INLET LINCOLN CENTER FLOODPLAIN REVISION HEC-RAS MODEL CROSS-SECTION RIVER: MAGNOLIA7 REACH: MASON-COLLEGE RIVER STATION: 2068 BASE FLOOD ELEVATION: 4995.8' (NAVD88) BACK OF WALK FLOODWAY BOUNDARY C/O UNDERDRAIN INV: 93.56' C/O UNDERDRAIN INV: 93.93' 8" CATCH BASIN INV: 93.39' 8" CATCH BASIN INV: 94.24' C/O UNDERDRAIN INV: 94.24' PROPOSED 36" DRY WELL INV. IN =92.98' INV. OUT 94.80' INV: 94.78' PROPOSED SIDEWALK CHASE PROPOSED 1' U-CHANNEL PROPOSED 1' U-CHANNEL 20.0' ROW 8" CATCH BASIN INV: 93.03' 8" CATCH BASIN INV: 94.68' C/O UNDERDRAIN INV: 93.21' 8" CATCH BASIN INV: 93.56' C/O UNDERDRAIN INV: 94.68' 8" CATCH BASIN INV: 93.46' C/O UNDERDRAIN INV: 93.46' FORT COLLINS 100-YR FLOOD FRINGE FORT COLLINS 100-YEAR FLOODWAY FORT COLLINS 100-YEAR FLOOD FRINGE FORT COLLINS 100-YEAR FLOODWAY FORT COLLINS 100-YEAR FLOOD FRINGE DRAINS TO PAVER SECTION #2 AREA = 632 SQ FT DRAINS TO STREET AREA = 461 SQ FT FORT COLLINS MODERATE RISK FLOODPLAIN LANDSCAPING AREA FORT COLLINS 100-YEAR FLOOD FRINGE FORT COLLINS 100-YEAR FLOODWAY FORT COLLINS 100-YEAR FLOOD FRINGE PAVER SECTION #1 PAVER SECTION #2 PAVER SECTION #4 DRAINS TO PAVER SECTION #1 AREA = 1,079 SQ FT DRAINS TO PAVER SECTION #4 AREA = 3,235 SQ FT FORT COLLINS MODERATE RISK FLOODPLAIN DRAINS TO PAVER SECTION #5 AREA = 2,144 SQ FT PAVER SECTION #3 PAVER SECTION #5 DRAINS TO PAVER SECTION #3 AREA = 1,529 SQ FT DRAINS TO STREET AREA = 418 SQ FT 39.5 LF OF 4" PERFORATED PVC PIPE 55.9 LF OF 4" PERFORATED PVC PIPE 29.9 LF OF 4" PERFORATED PVC PIPE 12.6 LF OF 4" PERFORATED PVC PIPE 38.6 LF OF 4" PERFORATED PVC PIPE 45.3 LF OF 4" PVC @ 0.4% 7.2 LF OF 4" PVC @16.8% 45.9 LF OF 4" PVC @ 0.4% 17.5 LF OF 4" PVC @ 0.4% 16.9 LF OF 4" PVC @ 0.76% 30.5 LF OF 4" PVC @ 4.5% 6.0 LF OF 4" PVC @1.0% 4.0 LF OF 6" PVC @0.5% PROPOSED 1' CURB CUT ELEVATION: 94.30' 4996 4996 4997 4997 4995 4996 4996 4997 4996 4995 4995 4995 4996 4995 4996 24.5 LF OF 4" PVC @ 0.4% 8" CATCH BASIN INV: 93.63' 4996 4997 4996 DRAINAGE PLAN C5.0 10' SCALE: 1" = 10' 0 20' DRAINAGE LEGEND D1 112 W. MAGNOLIA ST. PARKING 112 WEST MAGNOLIA STREET FORT COLLINS CO, 80525 FOR BURIED UTILITY INFORMATION THREE (3) BUSINESS DAYS BEFORE YOU DIG CALL 811 (OR 1-800-922-1987) UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) WWW.UNCC.ORG R P1 L.I.D. LEGEND BASIN ID MINOR "C" COEFFICIENT MAJOR "C" COEFFICIENT DRAINAGE AREA CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL E1 N SYMBOL LEGEND SANITARY LINE MAJOR CONTOUR MINOR CONTOUR CENTER LINE EASEMENT CONCRETE SIDEWALK FENCE UNDERGROUND TELEPHONE WATER MAIN UNDERGROUND POWER GAS LINE RIGHT-OF-WAY PROPERTY BOUNDARY FLOW LINE G G (UP) (UT) SS X WS WS WS WS WS SS FIRE HYDRANT WATER VALVE R/W WS WATER SERVICE LINE W R/W (OHP) OVERHEAD UTILITY EDGE OF ASPHALT DEMOLISH EXISTING STRUCTURE 10.00 2.05% W W FS E E E 11 FLOODPLAIN NOTES ENGINEERING & SURVEYING 4045 St. Cloud Drive, Suite 180 Loveland, CO 80538 [P] 970-622-2095 [F] 970-461-4469 DIRECTION OF FLOW WITH SLOPE AMOUNT SPOT ELEVATION MAJOR CONTOUR MINOR CONTOUR CONCRETE/ASPHALT DRIVE CONCRETE SIDEWALK EMERGENCY ACCESS BOUNDS FLOW LINE UNDERGROUND ELECTRIC LINE RIGHT-OF-WAY SANITARY LINE STORM SEWER PIPE FIRE LINE WATER LINE WATER SERVICE LINE PARKING COUNT WATER METER/ CURB STOP SANITARY SEWER MANHOLE SANITARY SEWER MANHOLE (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) (UP) SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W EXISTING BUILDING 4997 4996 4996 4995 4995 4995 4995 4996 4995 4995 95.10 96.27 95.95 96.11 96.95 HP 95.86 96.70 96.28 96.53 95.66 95.87 95.34 95.22 95.38 95.30 95.28 (95.34SW) 95.23 (94.47) (95.39) (96.48) 96.11 95.91 (94.62) 95.57 96.26 96.70 96.06 95.99 (95.32SW) (95.33SW) (95.69) (94.03) 95.40 96.11 96.45 96.37 96.50 95.47 95.32 95.95 95.87 96.53 95.51 96.76 HP (94.47) 96.17 95.57 95.25 (95.17) (96.55) 96.31 HP 96.45 96.21 95.83 95.00 LP 95.32 96.15 96.14 96.22 HP 96.53 96.85 95.19 (94.30) 96.56 95.47 94.81 LP 95.33 95.44 (96.59) 96.06 96.06 96.47 95.44 96.50 95.88 96.67 95.34 95.00 95.13 95.26 (94.57) (97.25) (95.26SW) (95.16SW) (95.27SW) 1.00% 0.50% 0.09% 1.80% 2.40% 2.18% 1.41% 0.50% 8.70% 7.02% 1.63% 2.00% (0.34%) (0.24%) (1.26%) 0.50% 1.00% 1.05% 2.57% 2.68% 2.73% 2.07% 1.00% 1.00% (1.21%) (0.32%) 1.00% 1.00% 1.23% 2.65% 14.98% 1.21% 2.32% 2.27% 0.17% 1.52% 2.40% 1.64% 1.34% 1.32% 4.18% 4.62% 1.66% 3.01% 0.50% 1.05% 0.50% 2.99% 0.50% 3.76% 4.82% 0.75% 0.85% 2.51% 2.75% 2.06% 1.60% 2.82% 2.62% 1.62% 2.40% 2.27% 0.50% 1.00% 1.92% 1.32% 8.60% 0.50% 0.50% 5.58% 2.00% 5.43% 5.40% 0.50% 1.00% 2.01% 2.04% 1.00% 4996 4997 4996 4997 4996 4996 4996 4995 4996 4997 4996 (95.20) (95.10) 94.78 94.70 94.60 95.30 95.30 95.20 95.20 96.37 95.37 96.42 95.67 96.43 96.79 95.97 96.05 95.98 (95.40) (95.53) 95.45 MAGNOLIA STREET 5 5 5 5 4 4 1 1 1 1 2 2 2 8 8 3 12 4 4 4 3 4 4 4 12 12 7 7 7 10 10 4 13 13 PROPERTY LINE/ROW PARKING SCREENING PER SITE PLANS EXISTING SIGN TO BE RELOCATED 9 14 COLLEGE AVENUE EXISTING TREE TO REMAIN 7 2 2 2 4995 4996 4996 5 11 6" CURB TO MATCH EXISTING 13 3 3 3 4 3 4 3 7 7 7 8 PROPOSED SWALE 3 Label conta CONSTRUCTION NOTES GRADING PLAN C4.0 FOR BURIED UTILITY INFORMATION THREE (3) BUSINESS DAYS BEFORE YOU DIG CALL 811 (OR 1-800-922-1987) UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) WWW.UNCC.ORG R 112 W. MAGNOLIA ST. PARKING 112 WEST MAGNOLIA STREET FORT COLLINS CO, 80525 (16.57) 16.25 SPOT ELEVATIONS CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL STREET CUT NOTE: 10' SCALE: 1" = 10' 0 20' N SYMBOL LEGEND G G (UP) (UT) SS (OHT) (OHP) (OHP) (OHP) SS R/W WS W R/W (OHP) 10.00 2.05% W W FS X X E E E 11 FLOODPLAIN NOTES: ENGINEERING & SURVEYING 4045 St. Cloud Drive, Suite 180 Loveland, CO 80538 [P] 970-622-2095 [F] 970-461-4469 NOTE: C4.0.... GRADING PLAN C5.0.... DRAINAGE PLAN C5.1.... EROSION CONTROL PLAN C5.2.... ALLEY PLAN AND PROFILE C6.0.... SITE DETAILS C6.1.... EROSION CONTROL DETAILS 1... 2... 3... 4... 5... 6... 7... 8... 9... 10... 11... CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL FOR BURIED UTILITY INFORMATION THREE (3) BUSINESS DAYS BEFORE YOU DIG CALL 811 (OR 1-800-922-1987) UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) WWW.UNCC.ORG R ENGINEER AFFIRMATION STATEMENT LANDSCAPE ARCHITECT LOTS 1 AND 2, BLOCK 113 TOWN OF FORT COLLINS, LOCATED IN THE NORTHEAST QUARTER (NE 1/4) OF SECTION 11, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. ENGINEERING & SURVEYING 4045 St. Cloud Drive, Suite 180 Loveland, CO 80538 [P] 970-622-2095 [F] 970-461-4469 TYPICAL ALLEY CROSS-SECTION SCALE: 1" = 1,000' VICINITY MAP N