HomeMy WebLinkAboutWELLS FARGO PARKING LOT AND ATMS - MJA190003 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANS (2)PROPOSED
GRADE
R.O.W R.O.W
20.0' ROW
19.0'
TRANSITION TO EXISTING
SLOPE OF 1.21%
LANDSCAPED AREA
SCARIFY AND RECOMPACT
SUBGRADE TO 95% MAX.
2" OF 1" DRY DENSITY
MINUS ROCK
8" OF 1"
CLEAN ROCK
6" OF FIBER
REINFORCED
CONCRETE
EXISTING GROUND
COVER SHEET
C1.0
112 W. MAGNOLIA ST. PARKING
112 WEST MAGNOLIA STREET
FORT COLLINS CO, 80525
SUPPLEMENTAL GENERAL NOTES:
ABBREVIATIONS
OWNER
LEGAL DESCRIPTION
BENCHMARK
SURVEYOR
112 W. MAGNOLIA ST. PARKING
MAJOR AMENDMENT OF FDP 180017 FOR
112 WEST MAGNOLIA STREET
FORT COLLINS CO, 80525
CIVIL ENGINEER
GEOTECHNICAL ENGINEER
SYMBOL LEGEND
NOVEMBER 2019
G G
(UP)
(UT)
SS
X
WS WS WS
SS
R/W
WS WS
W
R/W
(OHP)
10.00
2.05%
W
FS
E
SHEET INDEX
C1.0.... COVER SHEET
C1.1.... GENERAL NOTES I
C1.2.... GENERAL NOTES II
C2.0.... DEMOLITION PLAN
C3.0.... HORIZONTAL CONTROL AND UTILITY PLAN
GENERAL NOTES I
C1.1
112 W. MAGNOLIA ST. PARKING
112 WEST MAGNOLIA STREET
FORT COLLINS CO, 80525
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
FOR BURIED UTILITY INFORMATION
THREE (3) BUSINESS DAYS
BEFORE YOU DIG
CALL 811
(OR 1-800-922-1987)
UTILITY NOTIFICATION
CENTER OF COLORADO (UNCC)
WWW.UNCC.ORG
R
ENGINEERING & SURVEYING
4045 St. Cloud Drive, Suite 180
Loveland, CO 80538
[P] 970-622-2095 [F] 970-461-4469
5
6
4
5
2
FO
VB
S
(OHP) (OHP)
(OHP)
(OHP)
(OHP)
(FO)
(GAS)
(FO)
(GAS)
(GAS)
(GAS) (GAS) (GAS) (GAS)
(GAS) (GAS)
(GAS) (GAS)
(GAS) (GAS)
(GAS) (GAS)
(GAS) (GAS)
(GAS) (GAS) (GAS)
(GAS) (GAS)
(FO)
(FO) (FO) (FO) (FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO) (FO)
(FO)
(FO)
(FO)
(FO) (FO)
(FO)
(FO) (FO)
(FO)
(FO) (FO)
(FO)
(FO) (FO)
(GAS) (GAS)
(GAS) (GAS)
(GAS) (GAS)
(GAS)
(GAS) (GAS)
(GAS) (GAS)
(GAS)
(GAS)
(UP) (UP) (UP) (UP) (UP) (UP)
(UP)
(UP) (UP)
(UP)
5
6
4
5
2
FO
VB
S
(OHP)
(OHP)
(OHP) (OHP)
(OHP)
(FO)
(GAS)
(FO)
(GAS)
(GAS) (GAS) (GAS) (GAS)
(GAS)
(GAS)
(GAS) (GAS) (GAS)
(GAS)
(GAS) (GAS)
(GAS)
(GAS) (GAS)
(GAS) (GAS) (GAS) (GAS) (GAS)
(FO) (FO) (FO) (FO) (FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO)
(FO) (FO)
(FO) (FO) (FO)
(FO) (FO) (FO)
(FO)
(FO) (FO)
(FO) (FO)
(FO) (FO)
(FO)
(GAS) (GAS)
(GAS) (GAS)
(GAS) (GAS)
(GAS) (GAS)
(GAS)
(GAS) (GAS) (GAS) (GAS)
(UP) (UP) (UP) (UP) (UP) (UP)
(UP) (UP)
(UP)
(UP)
(UP)
(UP)
(UP)
(UP)
(UP)
(UP)
SITE DETAILS
C6.0
112 W. MAGNOLIA ST. PARKING
112 WEST MAGNOLIA STREET
FORT COLLINS CO, 80525
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
ENGINEERING & SURVEYING
4045 St. Cloud Drive, Suite 180
Loveland, CO 80538
[P] 970-622-2095 [F] 970-461-4469
DETAIL
NOT TO SCALE
SP-1
1' CONCRETE
U-CHANNEL
DETAIL
NOT TO SCALE
CATCH CURB SPILL CURB
SP-2
18" CURB & GUTTER
(UP) (UP) (UP)
(UP) (UP)
(UP)
(UP)
(UP)
(UP) (UP) (UP)
(UP)
(UP)
(UP)
(UP)
(UP)
(UP)
(UP) (UP)
(UP) (UP)
(UP)
(UP)
(UP)
(UP) (UP)
(UP) (UP) (UP)
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
W W
W W
W W W W W W
W
W W
W W W
W
W
W W
W
W W
W
W W
W W W W
W
W
W
EXISTING BUILDING
MAGNOLIA STREET
20.0' ROW
18.81'
PROPERTY LINE
EXISTING STORM INLET
LINCOLN CENTER FLOODPLAIN REVISION
HEC-RAS MODEL CROSS-SECTION
RIVER: MAGNOLIA7
REACH: MASON-COLLEGE
RIVER STATION: 2068
BASE FLOOD ELEVATION: 4995.8' (NAVD88)
BACK OF WALK
FLOODWAY BOUNDARY
C/O UNDERDRAIN
INV: 93.56'
C/O UNDERDRAIN
INV: 93.93'
8" CATCH BASIN
INV: 93.39'
8" CATCH BASIN
INV: 94.24'
C/O UNDERDRAIN
INV: 94.24'
PROPOSED
36" DRY WELL
INV. IN =92.98'
INV. OUT 94.80'
INV: 94.78'
PROPOSED
SIDEWALK
CHASE
PROPOSED 1' U-CHANNEL
PROPOSED 1' U-CHANNEL
20.0' ROW
8" CATCH BASIN
INV: 93.03'
8" CATCH BASIN
INV: 94.68'
C/O UNDERDRAIN
INV: 93.21'
8" CATCH BASIN
INV: 93.56'
C/O UNDERDRAIN
INV: 94.68'
8" CATCH BASIN
INV: 93.46'
C/O UNDERDRAIN
INV: 93.46'
FORT COLLINS 100-YR FLOOD FRINGE
FORT COLLINS 100-YEAR FLOODWAY
FORT COLLINS 100-YEAR FLOOD FRINGE
FORT COLLINS 100-YEAR FLOODWAY
FORT COLLINS 100-YEAR FLOOD FRINGE
DRAINS TO PAVER SECTION #2
AREA = 632 SQ FT
DRAINS TO STREET
AREA = 461 SQ FT
FORT COLLINS MODERATE RISK FLOODPLAIN
LANDSCAPING AREA
FORT COLLINS 100-YEAR FLOOD FRINGE
FORT COLLINS 100-YEAR FLOODWAY
FORT COLLINS 100-YEAR FLOOD FRINGE
PAVER SECTION #1
PAVER SECTION #2
PAVER SECTION #4
DRAINS TO PAVER SECTION #1
AREA = 1,079 SQ FT
DRAINS TO PAVER SECTION #4
AREA = 3,235 SQ FT
FORT COLLINS MODERATE RISK FLOODPLAIN
DRAINS TO PAVER SECTION #5
AREA = 2,144 SQ FT
PAVER SECTION #3
PAVER SECTION #5
DRAINS TO PAVER SECTION #3
AREA = 1,529 SQ FT
DRAINS TO STREET
AREA = 418 SQ FT
39.5 LF OF 4" PERFORATED PVC PIPE
55.9 LF OF 4" PERFORATED PVC PIPE
29.9 LF OF 4" PERFORATED PVC PIPE
12.6 LF OF 4" PERFORATED PVC PIPE
38.6 LF OF 4" PERFORATED PVC PIPE
45.3 LF OF 4" PVC @ 0.4%
7.2 LF OF 4" PVC @16.8%
45.9 LF OF 4" PVC @ 0.4%
17.5 LF OF 4" PVC @ 0.4%
16.9 LF OF 4" PVC @ 0.76%
30.5 LF OF 4" PVC @ 4.5%
6.0 LF OF 4" PVC @1.0%
4.0 LF OF 6" PVC @0.5%
PROPOSED 1' CURB CUT
ELEVATION: 94.30'
4996
4996
4997
4997
4995
4996
4996
4997
4996
4995
4995
4995
4996
4995
4996
24.5 LF OF 4" PVC @ 0.4%
8" CATCH BASIN
INV: 93.63'
4996
4997
4996
DRAINAGE PLAN
C5.0
10'
SCALE: 1" = 10'
0 20'
DRAINAGE LEGEND
D1
112 W. MAGNOLIA ST. PARKING
112 WEST MAGNOLIA STREET
FORT COLLINS CO, 80525
FOR BURIED UTILITY INFORMATION
THREE (3) BUSINESS DAYS
BEFORE YOU DIG
CALL 811
(OR 1-800-922-1987)
UTILITY NOTIFICATION
CENTER OF COLORADO (UNCC)
WWW.UNCC.ORG
R
P1
L.I.D. LEGEND
BASIN ID
MINOR "C" COEFFICIENT
MAJOR "C" COEFFICIENT
DRAINAGE AREA
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
E1
N
SYMBOL LEGEND
SANITARY LINE
MAJOR CONTOUR
MINOR CONTOUR
CENTER LINE
EASEMENT
CONCRETE SIDEWALK
FENCE
UNDERGROUND TELEPHONE
WATER MAIN
UNDERGROUND POWER
GAS LINE
RIGHT-OF-WAY
PROPERTY BOUNDARY
FLOW LINE
G G
(UP)
(UT)
SS
X
WS WS WS WS WS
SS
FIRE HYDRANT
WATER VALVE
R/W
WS WATER SERVICE LINE
W
R/W
(OHP) OVERHEAD UTILITY
EDGE OF ASPHALT
DEMOLISH EXISTING
STRUCTURE
10.00
2.05%
W W
FS
E E E
11
FLOODPLAIN NOTES
ENGINEERING & SURVEYING
4045 St. Cloud Drive, Suite 180
Loveland, CO 80538
[P] 970-622-2095 [F] 970-461-4469
DIRECTION OF FLOW
WITH SLOPE AMOUNT
SPOT ELEVATION
MAJOR CONTOUR
MINOR CONTOUR
CONCRETE/ASPHALT DRIVE
CONCRETE SIDEWALK
EMERGENCY ACCESS BOUNDS
FLOW LINE
UNDERGROUND ELECTRIC LINE
RIGHT-OF-WAY
SANITARY LINE
STORM SEWER PIPE
FIRE LINE
WATER LINE
WATER SERVICE LINE
PARKING COUNT
WATER METER/ CURB STOP
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
(UP)
(UP)
(UP) (UP)
(UP) (UP)
(UP) (UP)
(UP) (UP) (UP)
(UP)
(UP)
(UP)
(UP)
(UP) (UP)
(UP)
(UP)
(UP)
(UP)
(UP)
(UP)
(UP)
(UP) (UP)
(UP)
(UP)
(UP)
(UP)
(UP) (UP)
(UP) (UP)
(UP)
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
W
W W
W
W
W W W
W W W W W
W
W
W W W
W
W
W
W
W W
W W W W
W W
W
W W
EXISTING BUILDING
4997
4996
4996
4995
4995
4995
4995
4996
4995
4995
95.10
96.27
95.95 96.11
96.95 HP
95.86
96.70 96.28 96.53 95.66
95.87
95.34
95.22
95.38 95.30
95.28
(95.34SW)
95.23
(94.47)
(95.39)
(96.48)
96.11 95.91
(94.62)
95.57
96.26 96.70
96.06
95.99
(95.32SW)
(95.33SW)
(95.69)
(94.03)
95.40
96.11
96.45 96.37
96.50
95.47
95.32
95.95 95.87
96.53
95.51
96.76 HP
(94.47)
96.17
95.57
95.25
(95.17)
(96.55)
96.31 HP
96.45
96.21
95.83
95.00 LP 95.32
96.15
96.14
96.22 HP
96.53
96.85
95.19
(94.30)
96.56
95.47
94.81 LP
95.33
95.44
(96.59)
96.06
96.06
96.47
95.44
96.50
95.88
96.67 95.34
95.00
95.13
95.26
(94.57)
(97.25)
(95.26SW)
(95.16SW)
(95.27SW)
1.00%
0.50%
0.09%
1.80%
2.40%
2.18%
1.41%
0.50%
8.70%
7.02%
1.63%
2.00%
(0.34%) (0.24%)
(1.26%)
0.50%
1.00%
1.05%
2.57%
2.68%
2.73%
2.07%
1.00% 1.00%
(1.21%)
(0.32%)
1.00%
1.00%
1.23%
2.65%
14.98%
1.21%
2.32%
2.27%
0.17%
1.52%
2.40%
1.64%
1.34%
1.32%
4.18%
4.62%
1.66%
3.01%
0.50%
1.05%
0.50%
2.99%
0.50%
3.76%
4.82%
0.75%
0.85%
2.51%
2.75%
2.06%
1.60%
2.82%
2.62%
1.62%
2.40%
2.27%
0.50%
1.00%
1.92%
1.32%
8.60%
0.50%
0.50%
5.58%
2.00%
5.43%
5.40%
0.50%
1.00%
2.01%
2.04%
1.00%
4996
4997
4996
4997
4996
4996
4996
4995
4996
4997
4996
(95.20)
(95.10)
94.78
94.70
94.60
95.30
95.30
95.20 95.20
96.37
95.37
96.42 95.67
96.43
96.79
95.97 96.05
95.98
(95.40)
(95.53)
95.45
MAGNOLIA STREET
5
5
5
5
4
4
1
1
1
1
2
2 2
8
8
3 12
4
4 4
3
4
4
4
12 12
7
7
7
10
10
4 13
13
PROPERTY LINE/ROW
PARKING SCREENING
PER SITE PLANS
EXISTING SIGN TO
BE RELOCATED
9
14
COLLEGE AVENUE
EXISTING TREE
TO REMAIN
7
2
2
2
4995
4996
4996
5
11
6" CURB TO
MATCH EXISTING
13
3
3
3
4
3
4
3
7
7 7
8
PROPOSED SWALE
3
Label conta
CONSTRUCTION NOTES
GRADING PLAN
C4.0
FOR BURIED UTILITY INFORMATION
THREE (3) BUSINESS DAYS
BEFORE YOU DIG
CALL 811
(OR 1-800-922-1987)
UTILITY NOTIFICATION
CENTER OF COLORADO (UNCC)
WWW.UNCC.ORG
R
112 W. MAGNOLIA ST. PARKING
112 WEST MAGNOLIA STREET
FORT COLLINS CO, 80525
(16.57)
16.25
SPOT ELEVATIONS
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
STREET CUT NOTE:
10'
SCALE: 1" = 10'
0 20'
N
SYMBOL LEGEND
G G
(UP)
(UT)
SS
(OHT)
(OHP) (OHP) (OHP)
SS
R/W
WS
W
R/W
(OHP)
10.00
2.05%
W W
FS
X
X
E E E
11
FLOODPLAIN NOTES:
ENGINEERING & SURVEYING
4045 St. Cloud Drive, Suite 180
Loveland, CO 80538
[P] 970-622-2095 [F] 970-461-4469
NOTE:
C4.0.... GRADING PLAN
C5.0.... DRAINAGE PLAN
C5.1.... EROSION CONTROL PLAN
C5.2.... ALLEY PLAN AND PROFILE
C6.0.... SITE DETAILS
C6.1.... EROSION CONTROL DETAILS
1...
2...
3...
4...
5...
6...
7...
8...
9...
10...
11...
CITY OF FORT COLLINS, COLORADO
UTILITY PLAN APPROVAL
FOR BURIED UTILITY INFORMATION
THREE (3) BUSINESS DAYS
BEFORE YOU DIG
CALL 811
(OR 1-800-922-1987)
UTILITY NOTIFICATION
CENTER OF COLORADO (UNCC)
WWW.UNCC.ORG
R
ENGINEER AFFIRMATION STATEMENT
LANDSCAPE ARCHITECT
LOTS 1 AND 2, BLOCK 113 TOWN OF FORT COLLINS, LOCATED IN THE NORTHEAST QUARTER (NE 1/4) OF SECTION 11,
TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO.
ENGINEERING & SURVEYING
4045 St. Cloud Drive, Suite 180
Loveland, CO 80538
[P] 970-622-2095 [F] 970-461-4469
TYPICAL ALLEY CROSS-SECTION
SCALE: 1" = 1,000'
VICINITY MAP
N