Loading...
HomeMy WebLinkAboutRIDGEWOOD HILLS FIFTH FILING - PDP190018 - SUBMITTAL DOCUMENTS - ROUND 2 - VARIANCE REQUESTGalfloloway February 10, 2020 Marc Virata Engineering Development Review City of Fort Collins 281 N College Avenue Fort Collins, CO 80524 5265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 970.800.3300 • GallowayUS.com RE: Ridgewood Hills Filing No. 5 - Variance Request to LCUASS Chapter 7.4 Dear Marc, Please find this letter as our formal request for an administrative variance to the requirements set forth in Chapter 7.4 of the Larimer County Urban Area Street Standards (LCUASS) as they relate to tangential distances between horizontal curves and intersections. The project, Ridgewood Hills Filing No. 5, is located at the southwest corner of the intersections of Triangle Drive and US 287 in the City of Fort Collins. The project proposes an extension of Avondale Road to the south and east from the terminus of Avondale Road. The portion of Avondale Road that we will connect to is currently under construction with the Ridgewood Hills Filing No. 4, by others. Filing No. 4 will extend Avondale Road to Filing No. 5's west property boundary. A proposed residential connector, Field View Drive will intersect with the proposed Avondale Road approximately 175' to the east of the connection. Field View Drive begins a horizontal curve approximately 30' to the south of the intersection of Avondale Road. Table 7-3 within Chapter 7.4 outlines the minimum allowable tangential distances between horizontal curves and intersections based on the street classification. Field View Drive is classified as a residential connector and has a minimum tangential distance between horizontal curves and intersections of 100'. We would like to request a variance to Chapter 7.4 to allow for the reduced spacing of 30'. The horizontal geometry of Avondale Road is almost predetermined based on the provided connection point set by the Ridgewood Hills Filing No. 4 and a future connection to College Avenue at Carpenter Road, to be designed by others. The location and curvature of Field View Drive is limited to the obscure geometry of the project site and the desire to maximize the utility and density requirements of the site. Field View Drive, a public road, is proposed to provide access to private townhomes at the southwest corner of the site and must turn due south following the intersection with Avondale Road in order to provide serviceable lots for the townhomes. Given the lower classification of a residential connector road, stop signs will be required at Field View Drive for traffic crossing or headed onto Avondale Road. Therefore, it is not anticipated that the proposed geometry would pose any additiona detriment to safety or the design life or maintenance costs of Field View Drive. Thank you for your consideration of this variance request. Should you have any questions, please do not hesitate to contact me 970.800.3300. Sincerely, GALLOWAY Donald B. Cecil, P.E. Civil Project Engineer 970.800.3300 DonaldCecil@GallowayUS.com cc: