Loading...
HomeMy WebLinkAboutKS146_Utility Plans 2020-10-07 - FC Water Util Comments - RESPONSESRxPICKUP21 E E E E UTILITY PLANS FOR LOTS 1, 2, AND 4, OF K-MART PLAZA, AND ALL OF LOT 2 OF THE EXTENSION OF K-MART PLAZA, SITUATED IN THE SE 1/4 OF SECTION 23, T. 7 N., R. 69 W., OF THE 6TH P.M. CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO JULY 2020 MIDTOWN GARDENS MARKETPLACE - - - - - - - - - - - - - - STAMP H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_01-Covr.dwg - Matt Bundren - 10/7/2020Init.#Issue / DescriptionDate THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT GallowayUS.com 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate: Drawn By: Project No: Checked By: KSS000146 OF 13UTILITY PLANS FORMIDTOWN GARDENS MARKETPLACEKING SOOPERS MARKETPLACE #146S. COLLEGE AVE. & DRAKE RD.FORT COLLINS, COLORADOJULY 28, 2020 RDG PJD 1 COVER SHEET FC Water Utilities Comments Matt Simpson 10/29/2020 masimpson@fcgov.com Please provide sheet index SHEET INDEX PROVIDED WHERE PREVIOUSLY SHOWN, SEE BELOW - - - - - - - - - - - - - - STAMP H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_02-Notes.dwg - Matt Bundren - 10/7/2020Init.#Issue / DescriptionDate THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT GallowayUS.com 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate: Drawn By: Project No: Checked By: KSS000146 OF 13UTILITY PLANS FORMIDTOWN GARDENS MARKETPLACEKING SOOPERS MARKETPLACE #146S. COLLEGE AVE. & DRAKE RD.FORT COLLINS, COLORADOJULY 28, 2020 RDG PJD 2 GENERAL & CONSTRUCTION NOTES CO CO E E IR IR IR EVT ECB GM IR CO IR E E E E TL TL RI CO EM WM GM DYH DYH E IR GM ECB ECB DYH DYH ECB EME TL GM WM IR CO TL CO CO - - - - - - - - - - - - - - STAMP H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_03-Demo.dwg - Matt Bundren - 10/7/2020Init.#Issue / DescriptionDate THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT GallowayUS.com 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate: Drawn By: Project No: Checked By: KSS000146 OF 13UTILITY PLANS FORMIDTOWN GARDENS MARKETPLACEKING SOOPERS MARKETPLACE #146S. COLLEGE AVE. & DRAKE RD.FORT COLLINS, COLORADOJULY 28, 2020 SCALE: 1"=50' 0 20 5010 RDG PJD 3 EXISTING CONDITIONS & DEMOLITION PLAN EM WM SS CO DYH IR TL GM RI WMDYH CO GM IR E E EVT ECB Ex WT to be removed or abandoned (with MJ Cap). Please add note here Ex WT to remain Please add note here Ex WT to be removed. Please add note here Ex WT to remain Please add note here Exist. 8-inch Cast Iron Water Main - to be disconnected from Drake Rd 24-inch main. Remove 8-inch valve and plug Tee on 16inch main.. 8-inch WT main north from here may be abandoned with MJ plug and block. Exist. WT main may be abandoned in place There are 4 sewer taps on this main. These services need to be located and corresponding buildings identified Sewer Service Line To be removed (I agree) Ex. 1-inch water service to be abandoned at main. Ex 1.5-inch water service. Needs to be located and added to plans Needs to be reconnected to 16-inch (eastern) water main. The existing sewer service for this building needs to be located and shown on plans. Likely you will need a plumber to trace and mark the line. Water Utilities can help with dye testing. Please contact us to start this process. Please remove this section of storm pipe For final, please clean and inspect this service. Provide a detail for abandonment at storm manholes and inlet structures. We recommend removal or filling of existing storm pipes. Must concrete plug at downstream MH. (typ.) 4-inch water service to be removed and abandoned at water main. Water valve is on service line - to be removed The sewer service for this building needs to be located and shown on plans - if it comes onsite. 8-inch fire service 3-inch water service to be removed (?) 8-inch water main, with 1-inch water service 8-inch fire service to be removed existing storm drain to be removed and abandoned at inlet existing storm drain to be removed and abandoned at main CALLOUT ADDED PER COMMENT CALLOUT ADDED PER COMMENT CALLOUT ADDED PER COMMENT CALLOUT ADDED PER COMMENT EXISTING TAPS ALONG SEWER MAIN HAVE BEEN SHOWN WHERE KNOWN FROM THE CITY RECORD INFORMATION PROVIDED BY MATT SIMPSON. WE WILL CONTINUE TO WORK WITH THE CITY TO CONFIRM ALL EXISTING TAP LOCATIONS SHOWN CORRECTLY WITH FINAL CALLOUT ADDED AND EXISTING SERVICE SHOWN PER COMMENT CALLOUT REVISED TO SPECIFY MAIN TO BE ABANDONED IN PLACE PER COMMENT. ADDITIONAL DETAIL FOR THIS ABANDONMENT TO BE PROVIDED AT FINALCALLOUT REVISED TO SPECIFY MAIN TO BE ABANDONED IN PLACE & TO BE DISCONNECTED FROM DRAKE ROAD 24 IN MAIN PER COMMENT. ADDITIONAL DETAIL FOR THIS ABANDONMENT TO BE PROVIDED AT FINAL COMMENT NOTED. WE WILL CONTINUE TO WORK WITH THE CITY TO PROPERLY LOCATE AND SHOW THIS EXISTING SERVICE ON FINAL PLANS EXISTING SERVICE SHOWN AND CALLOUT ADDED TO SPECIFY PORTION OF EXISTING SERVICE TO BE RECONNECTED TO 16 INCH MAIN PER EXISTING "UTILITY PLANS FOR FULLER TEXACO" PROVIDED BY MATT SIMPSON, EX SANITARY SERVICE FOR THIS BUILDING RUNS EAST FROM BUILDING AND DOES NOT COME ONSITE (CONNECTS DIRECTLY INTO DRAKE ROAD ROW). NOTED. CALLOUT ADDED TO SPECIFY THAT BOTH EXISTING FIRE AND DOMESTIC SERVICE LINES TO BE REMOVED CALLOUT ADDED TO SPECIFY THIS SECTION OF EXISTING STORM SEWER TO BE REMOVED CALLOUT ADDED TO SPECIFY BOTH EXISTING SERVICE LINE AND WATER VALVE ON LINE TO BE REMOVED CALLOUT REVISED TO SPECIFY EX VALVE TO BE REMOVED NOTED, APPLICANT WILL CONTINUE TO WORK WITH CITY TO PROPERLY ADDRESS FOR FINAL. CALLOUT ADDED TO SPECIFY SERVICES/MAIN TO BE REMOVED NOTED, PER COORDINATION DISCUSSION WITH MATT SIMPSON, THIS DETAIL TO BE PROVIDED WITH FINAL EXISTING SERVICE SHOWN AND CALLOUT ADDED TO SPECIFY THIS SERVICE TO BE REMOVED CO CO E EVT ECB GM E E E E TL TL E TL GM IR TL - - - - - - - - - - - - - - STAMP H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_10-Grad.dwg - Matt Bundren - 10/7/2020Init.#Issue / DescriptionDate THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT GallowayUS.com 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate: Drawn By: Project No: Checked By: KSS000146 OF 13UTILITY PLANS FORMIDTOWN GARDENS MARKETPLACEKING SOOPERS MARKETPLACE #146S. COLLEGE AVE. & DRAKE RD.FORT COLLINS, COLORADOJULY 28, 2020 RDG PJD 10 GRADING PLAN SCALE: 1"=50' 0 20 5010 FFE FFE? LABEL ADDED PER COMMENT LABEL ADDED PER COMMENT COCOGMEEEEGMIREKM PJD DRAINAGE PLAN 11 SCALE: 1"=50' 0 20 5010 UTILITY PLANS FOR LOTS 1, 2, AND 4, OF K-MART PLAZA, AND ALL OF LOT 2 OF THE EXTENSION OF K-MART PLAZA, SITUATED IN THE SE 1/4 OF SECTION 23, T. 7 N., R. 69 W., OF THE 6TH P.M. CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO JULY 2020 MIDTOWN GARDENS MARKETPLACE - - - - - - - - - - - - - - STAMP H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\Exhibits\KSS146_Drainage_Proposed.dwg - Matt Bundren - 10/7/2020Init.#Issue / DescriptionDate THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT GallowayUS.com 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate: Drawn By: Project No: Checked By: KSS000146 OF 13UTILITY PLANS FORMIDTOWN GARDENS MARKETPLACEKING SOOPERS MARKETPLACE #146S. COLLEGE AVE. & DRAKE RD.FORT COLLINS, COLORADOJULY 28, 2020 Drainage Plan? Add FFE ? Label spill containment structure Remove this pipe 50 ft Please capture runoff from OS-3 and route to spill containment. It appears that this area may drain to OS-4 or OS-3. can you provide more grading detail here? Do you know where roof downspouts will end up? I would like the roof top to drain into an onsite basin and not to OS-6 or OS-5. ID the min. overtopping elevations. WQ treatment needs to be provided for this area. Please add: -subbasin summary table (basin, area, C, Q2, Q100) -detention summary table (WSEL100, release rates, volume) -summary of WQ and LID - required and provided. per discussions with the city, it is infeasible to capture this area, which is acceptable to the city added overflow elevation label blue area is roof area and part oc C-2. the remaining green area is part of OS-4 as shown an inlet has been aded to cap- ture a portion of OS-3 (orange area). the remainder is infea- sible to capture on-site, which is acceptable per discussions with the city removed storm line added overflow elevation labels downspouts will fall on the east and west (front and back) sides of the building, not onto OS-5 & OS 6 revised callout to identify spill containment added FFE information above has been added as requested title block updated for clarity CO CO E EVT ECB GM E E E E TL TL E TL GM IR TL CO CO E - - - - - - - - - - - - - - STAMP H:\King Soopers - City Market\CO, Fort Collins - KSS000146 -#18 College & Drake\CADD\2-Plan\Kss146_P_13-Util.dwg - Matt Bundren - 10/7/2020Init.#Issue / DescriptionDate THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT GallowayUS.com 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate: Drawn By: Project No: Checked By: KSS000146 OF 13UTILITY PLANS FORMIDTOWN GARDENS MARKETPLACEKING SOOPERS MARKETPLACE #146S. COLLEGE AVE. & DRAKE RD.FORT COLLINS, COLORADOJULY 28, 2020 RDG PJD 13 UTILITY PLAN SCALE: 1"=50' 0 20 5010 EM WV WM SS CODYH IR ECB TL E EVT GM RI E SCALE: 1"=30' 0 15 30 preferred storm outfall option 1 Will there be WT/ SS services stubbed for this lot? Remove this storm pipe 3-inch water meter and vault - needs to be located in a landscape area, may not be located in a driveable area If the City can relocate the FH line and fire service on the northern properties this whole water line can go away. (FYI) Extend UT easement to include curb stop Please confirm the UT easement is centered on the WT main. (need 10-feet each side of main). If not, please re-dedicate easement. Would like this FH relocated. -FH may not be located in "painted" parking lot island. -This location is vulnerable to be hit by turning trucks. -May need to coordinate with PFA. Please reconnect 8- inch water line like this. Exist WT service to be relocated to 16- inch WT main. Would like to remove this MH if possible. Do not show curb stop on 3-inch service. Show 4-inch valve attached to main with reducer to 3- inch service Show sewer service for this building. Forestry would like to save this tree (#15) if possible. preferred storm outfall option 2 prefer to loose tree #16 instead My review of your calculations shows there should be more detention system volume provided (see drainage report redlines). Let's discuss this however before making adjustments to the detention system. stormtech chamber needs to stay outside of critical root zone for existing tree. please provide 15-ft separation from tree to excavation and stormtech system. 15.11 ft Provide 6-ft min. separation between water service and electrical Discuss with Poudre Fire Authority if this hydrant is needed. If yes, let's have a coordination discussion with FC Electric (Cody Snowdon) about placement. Note SS service sizes revised outfall alignment per Option 2 revised outfall alignment per Option 2 revised outfall alignment per Option 2 revised detention layout with 15' clear- ance from existing trees PER COORDINATION WITH PFA & MATT SIMPSON, THIS PROPOSED HYDRANT HAS BEEN REMOVED AND IS NOT REQUIRED.UTILITY SERVICE ROUTING REVISED TO SHOW MIN 6' SEPARATION PROVIDED EX STORM PIPE REMOVED PER COMMENT. PER COORDINATION WITH PFA & MATT SIMPSON, THIS PROPOSED HYDRANT HAS BEEN REMOVED AND IS NOT REQUIRED. PROPOSED EASEMENT EXTENDED TO INCLUDE 3/4" METER PER COMMENT REVISED PER COMMENT REVISED PER COMMENTSITE PLAN MODIFIED TO PROVIDE CURBED ISLAND WITH LANDSCAPE FOR WATER METER AND VAULT. removed per comment revised water main connection as shown currently, service stubs for this lot are not anticipated with the proposed improvements Per coordination with PFA and Matt Simpson, Fire hydrant has remained in current proposed island with the addition of curb head around the island. Hydrant has been shifted further east into the is- land area by removing an additional parking stall to provide additional clearance from vehicular movement through site. sizes shown on revised plans per coordination discussion with Matt Simpson, existing water easement to remain as shown in existing alignment on water main revised outfall alignment per Option 2 callout revised to indicate to relocate existing service to 16" water main per comment detention volume as been increased as re- quested and per comments/discussions with the City