Loading...
HomeMy WebLinkAboutSupporting Documentation - Electrical - 11/19/2025 WORD\DATA\FORMS\C-1.DOC REV.August 14, 2020 CUSTOMER OWNED SERVICE INFORMATION FORM (C-1) City of Ft. Collins Electric Utility  700 Wood St.  P.O. Box 580  Ft. Collins, CO 80522 (970)221-6700 or fax (970)221-6619 Service voltages available are (not all voltages are available at all locations):  120/240 V. 1 phase, 3 wire  120/208 V. 3 phase, 4 wire  120/208 V. 1 phase, 3 wire (network)  277/480 V. 3 phase, 4 wire  Primary 13,200 V. Grd Y /7620  120/240 V. 3 phase, 4 wire (special utility permission required) For CT’d meters, Light and Power will provide the meter socket and CT’s to the electrical contractor. CT’s cannot be placed in the transformer, but may be located in a building mounted cabinet (provided by owner) or in the owner’s switchgear. In no case, can meters be mounted on the transformer. · Cold sequencing is required for all commercial services that are direct metered. · If CT’d metering, the owner must provide and install a - 1” conduit from the CT location to the electric meter. Please complete the following completely and legibly: Date Submitted: _____________________________________ Voltage Requested: _____/_____  1 phase OR  3 phase Building Main (not fuse) Size: ____________________ Amps Number of Conduits: _______ Size of Conduits:_________ Number of Cables: ________ Size of Cables: ___________ Electric Heat:  Yes _________kW  No Business Name: ____________________________________ Site Address: ______________________________________ Owners Name: _____________________________________ Mail Address: ______________________________________ City: ______________________________________________ State & Zip: ________________________________________ Phone: ____________________________________________ Email: ____________________________________________ General Contractor: _________________________________ Individual: _________________________________________ Mail Address: ______________________________________ City: ______________________________________________ State & Zip: ________________________________________ Phone: ____________________________________________ Email: ____________________________________________ Electrical Contractor: ________________________________ Mail Address: ______________________________________ City: ______________________________________________ State & Zip: ________________________________________ Phone: ____________________________________________ Firm: ______________________________________________ Email: _____________________________________________ Number of CT’d meters: __________ at ___________Amps each Number of Self-Contained meters: _____ at ________Amps each Largest Motor: ________ H.P. 1 Phase __________ H.P. 3 Phase Will any generating system (including photo-voltaics) be installed?  Yes (contact utility for requirements)  No If Yes, this will be for:  emergency service  parallel generation Will a fire pump be installed?  Yes  No Form Completed by: Name: ________________________________________________ Company:_____________________________________________ Mail Address: _________________________________________ City: _________________________________________________ State & Zip: ___________________________________________ Phone: _______________________________________________ Email: ________________________________________________ For Office Use Only Transformer Size: _________________________________kVA Fault Current at Transformer: _______________________Amps 100% Construction - Cont. # ____________ Paid: ____________ A.T.E. Date: _____________________ Engineering Approval by: ______________ Date: _____________ Metering Approval by: _________________ Date: _____________ Prospect Ridge Ft. Collins, Colorado Lot 4 RESIDENCE LOAD CALCULATIONS UNIT I BEDROOM LIGHTING 726 SF x 3 VA/SF N.E.C. 220.12 = 2,178 VA SMALL APPLIANCE LOAD 1,500 VA x 2 N.E.C. 220.52(A) = 3,000 VA DISPOSAL 830 VA x 1 N.E.C. 220.14 = 830 VA DISHWASHER 1,150 VA x 1 N.E.C. 220.14 = 1,150 VA REFRIGERATOR 900 VA x 1 N.E.C. 220-14 = 900 VA MICROWAVE 1,500 VA x 1 N.E.C. 220.14 = 1,500 VA WATER HEATER 18.75 AMPS X 1 N.E.C. 220-14 = 4,500 VA LAUNDRY LOAD 1,500 VA x 1 N.E.C. 220-52(b) = 1,500 VA DRYER 5,000 VA x 1 N.E.C. 220-54 = 5,000 VA RANGE N.E.C. 220.55 = 10,000 VA SUBTOTAL = 30,558 VA DEMAND FACTOR CALCULATIONS: FIRST 10,000 VA @ 100% = 10,000 VA BALANCE 20,558 VA @ 40%NEC 220.82(B)= 8,223 VA HEAT PUMP - 5KW HEAT 27.5 AMPS X 1 N.E.C. 220-82(C)= 6,600 VA HP -COND UNIT 2-TON 13.5 AMPS X 1 N.E.C. 220.82(C) = 0 VA *** TOTAL LOAD 120 / 240V 1ph 103 AMPS = 24,823 VA *** NON-COINCIDENTAL LOAD UNIT 2 BEDROOM LIGHTING 946 SF x 3 VA/SF N.E.C. 220.12 = 2,838 VA SMALL APPLIANCE LOAD 1,500 VA x 2 N.E.C. 220.52(A) = 3,000 VA DISPOSAL 830 VA x 1 N.E.C. 220.14 = 830 VA DISHWASHER 1,150 VA x 1 N.E.C. 220.14 = 1,150 VA REFRIGERATOR 900 VA x 1 N.E.C. 220-14 = 900 VA MICROWAVE 1,500 VA x 1 N.E.C. 220.14 = 1,500 VA WATER HEATER 18.75 AMPS X 1 N.E.C. 220-14 = 4,500 VA LAUNDRY LOAD 1,500 VA x 1 N.E.C. 220-52(b) = 1,500 VA DRYER 5,000 VA x 1 N.E.C. 220-54 = 5,000 VA RANGE N.E.C. 220.55 = 10,000 VA SUBTOTAL = 31,218 VA DEMAND FACTOR CALCULATIONS: FIRST 10,000 VA @ 100% = 10,000 VA BALANCE 21,218 VA @ 40%NEC 220.82(B)= 8,487 VA HEAT PUMP - 5KW HEAT 27.5 AMPS X 1 N.E.C. 220-82(C)= 6,600 VA HP -COND UNIT 2.5-TON 16.3 AMPS X 1 N.E.C. 220.82(C) = 0 VA *** TOTAL LOAD 120 / 240V 1ph 105 AMPS = 25,087 VA *** NON-COINCIDENTAL LOAD UNIT 3 BEDROOM LIGHTING 1,438 SF x 3 VA/SF N.E.C. 220.12 = 4,314 VA Page 1 of 4 Prospect Ridge Ft. Collins, Colorado Lot 4 SMALL APPLIANCE LOAD 1,500 VA x 2 N.E.C. 220.52(A) = 3,000 VA DISPOSAL 830 VA x 1 N.E.C. 220.14 = 830 VA DISHWASHER 1,150 VA x 1 N.E.C. 220.14 = 1,150 VA REFRIGERATOR 900 VA x 1 N.E.C. 220-14 = 900 VA MICROWAVE 1,500 VA x 1 N.E.C. 220.14 = 1,500 VA WATER HEATER 18.75 AMPS X 1 N.E.C. 220-14 = 4,500 VA LAUNDRY LOAD 1,500 VA x 1 N.E.C. 220-52(b) = 1,500 VA DRYER 5,000 VA x 1 N.E.C. 220-54 = 5,000 VA RANGE N.E.C. 220.55 = 10,000 VA SUBTOTAL = 32,694 VA DEMAND FACTOR CALCULATIONS: FIRST 10,000 VA @ 100% = 10,000 VA BALANCE 22,694 VA @ 40%NEC 220.82(B)= 9,078 VA HEAT PUMP - 8KW HEAT 43.3 AMPS X 1 N.E.C. 220-82(C)= 10,392 VA HP -COND UNIT 3-TON 19.2 AMPS X 1 N.E.C. 220.82(C) = 0 VA *** TOTAL LOAD 120 / 240V 1ph 123 AMPS = 29,470 VA *** NON-COINCIDENTAL LOAD UNIT 3 BEDROOM LIGHTING 1,278 SF x 3 VA/SF N.E.C. 220.12 = 3,834 VA SMALL APPLIANCE LOAD 1,500 VA x 2 N.E.C. 220.52(A) = 3,000 VA DISPOSAL 830 VA x 1 N.E.C. 220.14 = 830 VA DISHWASHER 1,150 VA x 1 N.E.C. 220.14 = 1,150 VA REFRIGERATOR 900 VA x 1 N.E.C. 220-14 = 900 VA MICROWAVE 1,500 VA x 1 N.E.C. 220.14 = 1,500 VA WATER HEATER 18.75 AMPS X 1 N.E.C. 220-14 = 4,500 VA LAUNDRY LOAD 1,500 VA x 1 N.E.C. 220-52(b) = 1,500 VA DRYER 5,000 VA x 1 N.E.C. 220-54 = 5,000 VA RANGE N.E.C. 220.55 = 10,000 VA SUBTOTAL = 32,214 VA DEMAND FACTOR CALCULATIONS: FIRST 10,000 VA @ 100% = 10,000 VA BALANCE 22,214 VA @ 40%NEC 220.82(B)= 8,886 VA HEAT PUMP - 8KW HEAT 43.3 AMPS X 1 N.E.C. 220-82(C)= 10,392 VA HP -COND UNIT 3-TON 19.2 AMPS X 1 N.E.C. 220.82(C) = 0 VA *** TOTAL LOAD 120 / 240V 1ph 122 AMPS = 29,278 VA *** NON-COINCIDENTAL LOAD BUILDING LOAD CALCULATIONS LIGHTING 1 BEDROOM 726 SF x 3 VA / SF x 9 = 19,602 VA LIGHTING 2 BEDROOM 946 SF x 3 VA / SF x 58 = 164,604 VA LIGHTING 3 BEDROOM 1,438 SF x 3 VA / SF x 9 = 38,826 VA Page 2 of 4 Prospect Ridge Ft. Collins, Colorado Lot 4 LIGHTING 3 BEDROOM 1,278 SF x 3 VA / SF x 21 = 80,514 VA SMALL APPLIANCE 3,000 VA x 97 = 291,000 VA LAUNDRY 1,500 VA x 97 = 145,500 VA CLOTHES DRYER 5,000 VA x 97 = 485,000 VA DISPOSAL 830 VA x 97 = 80,510 VA DISHWASHER 1,150 VA x 97 = 111,550 VA MICROWAVE 1,500 VA x 97 = 145,500 VA REFRIGERATOR 900 VA x 97 = 87,300 VA WATER HEATER 18.75 AMPS X 97 = 436,500 VA RANGE 10,000 VA x 97 = 970,000 VA HEAT PUMP - 5KW HEAT 27.5 AMPS X 9 = 51,480 VA HP -COND UNIT 2-TON 13.5 AMPS X 9 = 0 VA *** HEAT PUMP - 5KW HEAT 27.5 AMPS X 67 = 383,240 VA HP -COND UNIT 2.5-TON 16.3 AMPS X 67 = 0 VA *** HEAT PUMP - 8KW HEAT 43.3 AMPS X 30 = 270,192 VA HP -COND UNIT 3-TON 19.2 AMPS X 30 = 0 VA *** SUBTOTAL = 3,761,318 VA DEMAND CALCULATIONS N.E.C. 220 RESIDENTIAL TOTAL 3,761,318 VA @ 23% TABLE 220.84 = 865,103 VA 2403 AMPS HOUSE PANEL H: EXTERIOR LIGHTING 3500 VA @ 125% = 4,375 VA INTERIOR LIGHTING 1000 VA @ 125% 4 = 5,000 VA RECEPTACLES (MISC) 180 VA @ 100% 20 = 3,600 VA HEAT PUMP - 5KW HEAT 27.5 A X 100% 7 = 40,040 VA HEAT PUMP EXTERIOR 2.5-TON 16.3 A X 100% 7 = 0 VA *** BASEBOARD HEAT 1500 VA @ 100% 8 = 12,000 VA MISC 10000 VA @ 100% 1 = 10,000 VA HOUSE PANEL LOAD 208 AMPS = 75,015 VA ELEVATOR LOAD LIGHTING 500 VA @ 125% = 625 VA RECEPTACLES (MISC) 1500 VA @ 100% = 1,500 VA HP-3 7056 VA @ 100% = 7,056 VA BLOWER 0.5 AMPS x 1 = 60 VA ELEVATOR 24390 VA @ 100% = 24,390 VA 25% LARGEST MOTOR 24390 VA @ 25% = 6,098 VA ELEVATOR SUMP 1130 VA @ 100% = 1,130 VA SUBTOTAL 113 AMPS = 40,859 VA HOUSE LOAD 322 AMPS = 115,874 VA RETAIL SPACE LIGHTING 8,824 SF x 3.5 VA/SF @ 125% = 30,884 VA Page 3 of 4 Prospect Ridge Ft. Collins, Colorado Lot 4 RECEPTACLES (MISC) 8,824 SF x 5.0 VA / SF @ 100% = 44,120 VA HP -8KW 43 A x 8 208V @ 100% = 83,136 VA HP COND - 4T 29 A x 8 208V @ 100% = 0 VA *** MISC POWER 8824 SF x 5.0 VA/SF @ 100%= 44,120 VA RETAIL LOAD = 202,260 VA *** NON-COINCIDENTAL LOAD 562 AMPS EV CHARGING LIGHTING 500 VA @ 125% = 625 VA RECEPTACLES (MISC) 180 VA X 10 @ 100% = 1,800 VA COMMERCIAL BLOCK 50,000 VA x 125% 6 LEVEL 3 = 375,000 VA SUBTOTAL 1,048 AMPS = 377,425 VA OVERALL ELECTRICAL SERVICE TO BUILDING RESIDENTIAL SERVICE = 865,103 VA HOUSE SERVICE AND ELEVATOR = 115,874 VA RETAIL AREA = 202,260 VA EV CHARGING = 377,425 VA MISC SERVICE FOR FUTURE REVISIONS TOTAL SERVICE TO THE BUILDING 4,335 AMPS = 1,560,662 VA Page 4 of 4